1 ## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom
2 This is a low-level design implemented as an extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. Content has been copied from [FD.io CSIT testbeds wiki page: Xeon_skx, Arm, Atom](https://wiki.fd.io/view/CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom).
5 ### Testbeds Type Breakdown
7 #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node.
8 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2.
9 2. 2-node Xeon. perf. skx. skx. 4. 4. 4. 8.
10 3. 3-node Xeon. perf. skx. skx. 2. 4. 2. 6.
11 4. tcp-l47. tcp-stack. skx. ps1. 1. 1. 1. 1.
12 5. atom-netgate. perf+func. net. skx. 1. 3. 1. 1.
13 6. aarch64-d05 perf arm. skx. 1. 2. 1. 1/2.
14 7. aarch64-mcbin perf arm. skx. 1. 2. 1. 1/2.
15 8. 1-node aarch64 func arm. n/a. 1. 1. 0. 0.
19 ### 1-Node Xeon Testbeds
20 One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back.
22 ### 2-Node Xeon Testbeds
23 Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
25 ### 3-Node Xeon Testbeds
26 Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
28 ### 1-Node Arm Marvell ThunderX2 Testbed
29 One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using one SUT (Type-9 server), with NIC ports connected back-to-back.
31 ### 3-Node Arm Huawei TaiShan Testbed
32 One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
34 ### 3-Node Arm Marvell MACCHIATObin Testbed
35 One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle. Built-in NIC ports connectivity is following the testbed specification included in next sections.
37 ### TCP/IP and L47 Testbeds
38 One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
41 One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section.
46 1. Ixia PerfectStorm One Appliance
49 - Motherboard: SuperMicro X11DPG-QT.
50 - Processors: Quad-Core, Intel Processor.
51 - HW accelerators: FPGA offload.
53 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
54 - Physical Interfaces: 4 * 10GE SFP+.
55 - Operating System: Native IxOS.
60 1. Arm Cortex A-72 servers
62 - Chassis: Marvell ThunderX2
63 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
64 - RAM Memory: 4* 32GB RDIMM
65 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
66 - 2 * Huawei TaiShan 2280.
67 - Chassis: Huawei TaiShan 2280.
68 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
69 - RAM Memory: 8* 16GB DDR4-2400MT/s.
70 - Disks: 1* 4TB SATA HDD.
72 - Chassis: MACCHIATObin.
73 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
74 - RAM Memory: 1* 16GB DDR4.
75 - Disks: 1* 128GB(?) SATA SDD.
78 Platform Name and Specification | Role | Status | Hostname | IP | IPMI | Cores | RAM | Ethernet | Distro
79 ------------------------------- | ---- | ------ | -------- | -- | ---- | ----- | --- | -------- | ------
80 [SoftIron OverDrive 1000](https://softiron.com/development-tools/overdrive-1000/) | CI build server | Up, Not Running Jobs | softiron-1 | 10.30.51.12 | N/A | 4 | 8GB | | openSUSE
81 | | CI build server | Up, Not Running Jobs | softiron-2 | 10.30.51.13 | N/A | 4 | 8GB | | openSUSE
82 | | CI build server | Up, Not Running Jobs | softiron-3 | 10.30.51.14 | N/A | 4 | 8GB | | openSUSE
83 [Marvell ThunderX](https://www.marvell.com/server-processors/thunderx-arm-processors/) | CI build server | Up, Running VPP CI | nomad3arm | 10.30.51.38 | 10.30.50.38 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
84 | | CI build server | Up, Running VPP CI | nomad4arm | 10.30.51.39 | 10.30.50.39 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
85 | | CI build server | Up, Running VPP CI | nomad5arm | 10.30.51.40 | 10.30.50.40 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
86 | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad6arm | 10.30.51.65 | 10.30.50.65 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
87 | | VPP dev debug | Up | nomad7arm | 10.30.51.66 | 10.30.50.66 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
88 | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad8arm | 10.30.51.67 | 10.30.50.67 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
89 | | VPP dev debug | Up | nomad9arm | 10.30.51.68 | 10.30.50.68 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
90 [Marvell ThunderX2](https://www.marvell.com/server-processors/thunderx2-arm-processors/) | VPP device server | Being Provisioned | s27-t13-sut1 | 10.30.51.69 | 10.30.50.69 | 112 | 128GB | 3x40GbE QSFP+ XL710-QDA2 | Ubuntu 18.04.1
91 Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-sut1 | 10.30.51.36 | 10.30.50.36 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
92 | | CSIT Performance | Up, Manual perf experiments | s18-t33-sut2 | 10.30.51.37 | 10.30.50.37 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
93 [Marvell MACCHIATObin](http://macchiatobin.net/) | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s20-t34-sut1 | 10.30.51.41 | 10.30.51.49, then connect to /dev/ttyUSB0 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.4
94 | | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s21-t34-sut2 | 10.30.51.42 | 10.30.51.49, then connect to /dev/ttyUSB1 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
95 | | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
97 ### Xeon and Atom Servers
99 1. Intel Xeon servers:
100 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
101 - Chassis: SuperMicro SYS-7049GP-TRT.
102 - Motherboard: SuperMicro X11DPG-QT.
103 - Processors: 2* Intel Platinum 8180 2.3 GHz.
104 - RAM Memory: 16* 16GB DDR4-2666MHz.
105 - Disks: 2* 1.6TB 6G SATA SSD.
106 2. Intel Atom servers with Rangely processors.
107 - 3 * Netgate XG-2758-1u
108 - Chassis: Netgate XG-2758-1u
109 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
110 - RAM Memory: 16GB ECC
114 ### Network Interface Cards
117 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
118 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
119 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
121 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
123 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
125 - 4 * mcx556a-edat NICs (not on site yet, in transit)
128 ### Pluggables and Cables
132 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
133 - 80 * 10G SR optic (generic, "Intel" compatible branded)
139 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
149 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
154 ### Other Network Cards
157 ## Installation Status
158 Lab installation status is tracked by LF IT team in [FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
160 ## Server/Device Management and Naming
161 ### Server Management Requirements
162 Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
163 For management purposes, each server must have following two ports connected to the management network:
166 - IPMI - Intelligent Platform Management Interface.
167 - Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
168 - 1GE/10GE management port
169 - hostOS management port for general system management.
172 ### Server and Port Naming Convention
173 Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:
175 - testbedname: testbedN.
177 - traffic-generator: tN-tgW.
178 - system-under-testX: tN-sutX.
183 - N - testbed number.
184 - tgW - server acts as traffic-generator with W index.
185 - sutX - server acts as system-under-test with X index.
186 - Y - PCIe slot number denoting a NIC card number within the host.
187 - Y=2,4,9 - slots connected to NUMA node 0.
188 - Y=6,8,10 - slots connected to NUMA node 1.
189 - Z - port number on the NIC card.
192 ### Server Management - Addressing
193 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.
196 - Subnet: 10.30.50.0/24
197 - Gateway: 10.30.50.1
198 - Broadcast: 10.30.50.255
199 - DNS1: 199.204.44.24
200 - DNS2: 199.204.47.54
202 - Subnet: 10.30.51.0/24
203 - Gateway: 10.30.51.1
204 - Broadcast: 10.30.51.255
205 - DNS1: 199.204.44.24
206 - DNS2: 199.204.47.54
208 To access these hosts, an VPN connection is required.
210 ### LOM (IPMI) VLAN IP Addresses
213 ### Management VLAN IP Addresses
216 ## Testbeds Specification - Target Build
217 ### Server/Ports Naming, NIC Placement
219 Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
222 - testbedname: testbed11.
223 - hostname: s1-t11-sut1.
224 - IPMI IP: 10.30.50.47
225 - Host IP: 10.30.51.50
227 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
228 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
229 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
230 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
231 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
232 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
233 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
234 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
236 - testbedname: testbed12.
237 - hostname: s2-t12-sut1.
238 - IPMI IP: 10.30.50.48
239 - Host IP: 10.30.51.51
241 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
242 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
243 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
244 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
245 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
246 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
247 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
248 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
252 Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
255 - testbedname: testbed21.
256 - hostname: s3-t21-sut1.
257 - IPMI IP: 10.30.50.41
258 - Host IP: 10.30.51.44
260 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
261 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
262 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
263 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
264 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
265 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
266 - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
267 - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
269 - testbedname: testbed21.
270 - hostname: s4-t21-tg1.
271 - IPMI IP: 10.30.50.42
272 - Host IP: 10.30.51.45
274 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
275 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
276 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
277 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
278 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
279 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
280 - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
281 - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
283 - testbedname: testbed22.
284 - hostname: s5-t22-sut1.
285 - IPMI IP: 10.30.50.49
286 - Host IP: 10.30.51.52
288 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
289 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
290 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
291 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
292 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
293 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
294 - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
295 - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
297 - testbedname: testbed22.
298 - hostname: s6-t22-tg1.
299 - IPMI IP: 10.30.50.50
300 - Host IP: 10.30.51.53
302 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
303 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
304 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
305 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
306 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
307 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
308 - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
309 - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
311 - testbedname: testbed23.
312 - hostname: s7-t23-sut1.
313 - IPMI IP: 10.30.50.51
314 - Host IP: 10.30.51.54
316 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
317 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
318 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
319 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
320 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
321 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
322 - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
323 - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
325 - testbedname: testbed23.
326 - hostname: s8-t23-tg1.
327 - IPMI IP: 10.30.50.52
328 - Host IP: 10.30.51.55
330 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
331 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
332 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
333 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
334 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
335 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
336 - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
337 - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
339 - testbedname: testbed24.
340 - hostname: s9-t24-sut1.
341 - IPMI IP: 10.30.50.53
342 - Host IP: 10.30.51.56
344 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
345 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
346 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
347 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
348 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
349 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
350 - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
351 - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
353 - testbedname: testbed24.
354 - hostname: s10-t24-tg1.
355 - IPMI IP: 10.30.50.54
356 - Host IP: 10.30.51.57
358 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
359 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
360 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
361 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
362 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
363 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
364 - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
365 - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
369 Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
372 - testbedname: testbed31.
373 - hostname: s11-t31-sut1.
374 - IPMI IP: 10.30.50.43
375 - Host IP: 10.30.51.46
377 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
378 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
379 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
380 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
381 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
382 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
383 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
384 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
386 - testbedname: testbed31.
387 - hostname: s12-t31-sut2.
388 - IPMI IP: 10.30.50.44
389 - Host IP: 10.30.51.47
391 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
392 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
393 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
394 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
395 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
396 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
397 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
398 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
400 - testbedname: testbed31.
401 - hostname: s13-t31-tg1.
402 - IPMI IP: 10.30.50.45
403 - Host IP: 10.30.51.48
405 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
406 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
407 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
408 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
409 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
410 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
411 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
412 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
414 - testbedname: testbed32.
415 - hostname: s14-t32-sut1.
416 - IPMI IP: 10.30.50.55
417 - Host IP: 10.30.51.58
419 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
420 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
421 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
422 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
423 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
424 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
425 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
426 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
428 - testbedname: testbed32.
429 - hostname: s15-t32-sut2.
430 - IPMI IP: 10.30.50.56
431 - Host IP: 10.30.51.59
433 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
434 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
435 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
436 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
437 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
438 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
439 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
440 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
442 - testbedname: testbed32.
443 - hostname: s16-t32-tg1.
444 - IPMI IP: 10.30.50.57
445 - Host IP: 10.30.51.60
447 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
448 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
449 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
450 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
451 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
452 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
453 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
454 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
460 - testbedname: testbed13.
461 - hostname: s27-t13-sut1.
462 - IPMI IP: 10.30.50.69
463 - Host IP: 10.30.51.69
465 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
466 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
467 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
468 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
469 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
470 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
474 Note: Server19 (TG) is shared between testbed33 & testbed34
477 - testbedname: testbed33.
478 - hostname: s17-t33-sut1.
479 - IPMI IP: 10.30.50.36
480 - Host IP: 10.30.51.36
482 - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
483 - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
484 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
485 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
487 - testbedname: testbed33.
488 - hostname: s18-t33-sut2.
489 - IPMI IP: 10.30.50.37
490 - Host IP: 10.30.51.37
492 - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
493 - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
494 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
495 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
497 - testbednames: testbed33 and testbed34.
498 - hostname: s19-t33t34-tg1.
499 - IPMI IP: 10.30.50.46
500 - Host IP: 10.30.51.49
502 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
503 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
504 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
505 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
506 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
507 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
508 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
509 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
510 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
511 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
513 - testbedname: testbed34.
514 - hostname: s20-t34-sut1.
516 - Host IP: 10.30.51.41
518 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
519 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
521 - testbedname: testbed34.
522 - hostname: s21-t34-sut2.
524 - Host IP: 10.30.51.42
526 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
527 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
531 Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
534 - testbedname: testbed25.
535 - hostname: s25-t25-sut1.
536 - IPMI IP: 10.30.50.58
537 - Host IP: 10.30.51.61
539 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
540 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
541 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
542 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
544 - testbedname: testbed25.
545 - hostname: s26-t25-tg1.
546 - IPMI IP: 10.30.50.59
547 - Host IP: 10.30.51.62
549 - s26-t25-tg1-p1 - 10GE-port1.
550 - s26-t25-tg1-p2 - 10GE-port2.
551 - s26-t25-tg1-p3 - 10GE-port3.
552 - s26-t25-tg1-p4 - 10GE-port4.
556 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
559 - testbedname: testbed35.
560 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
561 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
562 - Host IP: 10.30.51.9
564 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
565 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
568 - testbedname: testbed35.
569 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
570 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
571 - Host IP: 10.30.51.10
573 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
574 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
577 - testbedname: testbed35.
578 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
579 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
580 - Host IP: 10.30.51.11
582 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
583 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
587 ### Physical Connectivity within Testbeds
589 Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification:
592 - ring1 10GE-ports x710-4p10GE:
593 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
594 - ring2 10GE-ports x710-4p10GE:
595 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
596 - ring3 10GE-ports x710-4p10GE:
597 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
598 - ring4 10GE-ports x710-4p10GE:
599 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
601 - ring1 10GE-ports x710-4p10GE:
602 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
603 - ring2 10GE-ports x710-4p10GE:
604 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
605 - ring3 10GE-ports x710-4p10GE:
606 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
607 - ring4 10GE-ports x710-4p10GE:
608 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
612 Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
615 - ring1 10GE-ports x710-4p10GE on SUT:
616 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
617 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
618 - ring2 10GE-ports x710-4p10GE on SUT:
619 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
620 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
621 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
622 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
623 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
624 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
625 - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
626 - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
627 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
628 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
629 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
631 - ring1 10GE-ports x710-4p10GE on SUT:
632 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
633 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
634 - ring2 10GE-ports x710-4p10GE on SUT:
635 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
636 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
637 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
638 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
639 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
640 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
641 - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
642 - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
643 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
644 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
645 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
647 - ring1 10GE-ports x710-4p10GE on SUT:
648 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
649 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
650 - ring2 10GE-ports x710-4p10GE on SUT:
651 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
652 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
653 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
654 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
655 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
656 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
657 - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
658 - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
659 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
660 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
661 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
663 - ring1 10GE-ports x710-4p10GE on SUT:
664 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
665 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
666 - ring2 10GE-ports x710-4p10GE on SUT:
667 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
668 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
669 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
670 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
671 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
672 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
673 - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
674 - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
675 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
676 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
677 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
681 Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification:
684 - ring1 10GE-ports x710-4p10GE on SUTs:
685 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
686 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
687 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
688 - ring2 10GE-ports x710-4p10GE on SUT:
689 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
690 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
691 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
692 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
693 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
694 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
695 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
696 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
697 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
698 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
699 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
700 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
701 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
702 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
704 - ring1 10GE-ports x710-4p10GE on SUTs:
705 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
706 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
707 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
708 - ring2 10GE-ports x710-4p10GE on SUT:
709 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
710 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
711 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
712 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
713 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
714 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
715 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
716 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
717 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
718 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
719 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
720 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
721 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
722 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
727 One 1-Node testbed is constructed by connecting 1 Arm server using below specification:
730 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
731 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
732 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
733 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
734 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
735 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
740 One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon server using below specification:
743 - ring1 10GE-ports 82599-2p10GE on SUTs:
744 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
745 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
746 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
747 - ring2 25GE-ports cx4-2p25GE on SUTs:
748 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
749 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
750 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
752 One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one Xeon server using below specification:
755 - ring1 10GE-ports Marvell on SUTs:
756 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
757 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
758 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
762 One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification:
765 - link1 10GE-port x710-4p10GE on SUT:
766 - t25-tg1-p1 to t25-sut1-c2/p1.
767 - link2 10GE-port x710-4p10GE on SUT:
768 - t25-tg1-p2 to t25-sut1-c2/p2.
769 - link3 10GE-port x710-4p10GE on SUT:
770 - t25-tg1-p3 to t25-sut1-c2/p3.
771 - link4 10GE-port x710-4p10GE on SUT:
772 - t25-tg1-p4 to t25-sut1-c2/p4.
778 ## Server Specification
779 ### Hardware Configuration
780 The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations:
782 1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
783 - Quantity: TBD based on testbed allocation.
784 - Physical connectivity:
785 - IPMI and host management ports.
786 - NIC ports connected into 2-node and 3-node topologies.
787 - Main HW configuration:
788 - Chassis: SuperMicro SYS-7049GP-TRT.
789 - Motherboard: SuperMicro X11DPG-QT.
790 - Processors: 2* Intel Platinum 8180 2.3 GHz.
791 - RAM Memory: 16* 16GB DDR4-2666MHz.
792 - Disks: 2* 1.6TB 6G SATA SSD.
793 - NICs configuration:
794 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
795 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
796 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
797 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
798 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
799 - PCIe Slot6 86:00.xx: empty.
800 - PCIe Slot8 af:00.xx: empty.
801 - PCIe Slot10 d8:00.xx: empty.
802 2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
803 - Quantity: TBD based on testbed allocation.
804 - Physical connectivity:
805 - IPMI and host management ports.
806 - NIC ports connected into 2-node and 3-node topologies.
807 - Main HW configuration:
808 - Chassis: SuperMicro SYS-7049GP-TRT.
809 - Motherboard: SuperMicro X11DPG-QT.
810 - Processors: 2* Intel Platinum 8180 2.3 GHz.
811 - RAM Memory: 16* 16GB DDR4-2666MHz.
812 - Disks: 2* 1.6TB 6G SATA SSD.
813 - NICs configuration:
814 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
815 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
816 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
817 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
818 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
819 - PCIe Slot6 86:00.xx: empty.
820 - PCIe Slot8 af:00.xx: empty.
821 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
822 3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
824 - Physical connectivity:
825 - IPMI(?) and host management ports.
826 - NIC ports connected into 3-node topology.
827 - Main HW configuration:
828 - Chassis: Huawei TaiShan 2280.
829 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
830 - RAM Memory: 8* 16GB DDR4-2400MT/s
831 - Disks: 1* 4TB SATA HDD
832 - NICs configuration:
833 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
834 - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
835 4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
837 - Physical connectivity:
838 - Host management ports.
839 - NIC ports connected into 2-node and 3-node topologies.
840 - Main HW configuration:
841 - Chassis: MACCHIATObin.
842 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
843 - RAM Memory: 1* 16GB DDR4
844 - Disks: 1* 128GB(?) SATA SDD
845 - NICs configuration:
846 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
847 5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
848 - Quantity: TBD based on testbed allocation.
849 - Physical connectivity:
850 - Management: serial Port (usb) for console
851 - NIC ports connected into 2-node.
852 - Main HW configuration:
853 - Chassis: Netgate XG-2758-1u
854 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
855 - RAM Memory: 16GB ECC
857 - NICs configuration:
858 - 2x 10Gb Intel 82599ES
860 6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
862 - Physical connectivity:
863 - IPMI and host management ports.
864 - NIC ports connected into 2-node and 3-node topologies.
865 - Main HW configuration:
866 - Chassis: SuperMicro SYS-7049GP-TRT.
867 - Motherboard: SuperMicro X11DPG-QT.
868 - Processors: 2* Intel Platinum 8180 2.3 GHz.
869 - RAM Memory: 16* 16GB DDR4-2666MHz.
870 - Disks: 2* 1.6TB 6G SATA SSD.
871 - NICs configuration:
872 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
873 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
874 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
875 - PCIe Slot9 5e:00.xx: empty.
876 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
877 - PCIe Slot6 86:00.xx: empty.
878 - PCIe Slot8 af:00.xx: empty.
879 - PCIe Slot10 d8:00.xx: empty.
880 7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests.
882 - Physical connectivity:
883 - Host management interface: 10/100/1000-BaseT.
884 - 8-port 10GE SFP+ integrated NIC.
885 - Main HW configuration:
886 - Chassis: PS10GE4NG.
887 - Motherboard: SuperMicro X11DPG-QT.
888 - Processors: Quad-Core, Intel Processor.
889 - HW accelerators: FPGA offload.
891 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
892 - Physical Interfaces: 4 * 10GE SFP+.
893 - Operating System: Native IxOS.
894 - Interface configuration:
899 8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
901 - Physical connectivity:
902 - IPMI and host management ports.
904 - Main HW configuration:
905 - Chassis: SuperMicro SYS-7049GP-TRT.
906 - Motherboard: SuperMicro X11DPG-QT.
907 - Processors: 2* Intel Platinum 8180 2.3 GHz.
908 - RAM Memory: 16* 16GB DDR4-2666MHz.
909 - Disks: 2* 1.6TB 6G SATA SSD.
910 - NICs configuration:
911 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
912 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
913 - PCIe Slot4 3b:00.xx: empty.
914 - PCIe Slot9 5e:00.xx: empty.
915 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
916 - PCIe Slot6 86:00.xx: empty.
917 - PCIe Slot8 af:00.xx: empty.
918 - PCIe Slot10 d8:00.xx: empty.
919 9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional tests.
921 - Physical connectivity:
922 - IPMI and host management ports.
923 - NIC ports connected into 1-node topologies.
924 - Main HW configuration:
925 - Chassis: Gigabyte R181-T90 1U
926 - Motheboard: MT91-FS1
927 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
928 - RAM Memory: 4* 32GB RDIMM
929 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
930 - NICs configuration:
932 - PCIe Slot1 05:00.xx: XL710-QDA2.
933 - PCIe Slot3 08:00.xx: XL710-QDA2.
935 - PCIe Slot6 85:00.xx: XL710-QDA2.
936 10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
938 - Physical connectivity:
939 - IPMI and host management ports.
941 - Main HW configuration:
942 - Chassis: SuperMicro SYS-E300-9A
943 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
944 - RAM Memory: 32GB ECC
946 - NICs configuration:
947 - 2x 10Gb Intel x553 fiber ports
948 - 2x 10Gb Intel x553 copper ports
949 - 4x 1GB Intel I350 ports
952 ### Xeon Skx Server BIOS Configuration
955 | Quiet Boot [Enabled] |Boot option |
957 | Option ROM Messages [Force BIOS] | |
958 | Bootup NumLock State [On] | |
959 | Wait For "F1" If Error [Enabled] | |
960 | INT19 Trap Response [Immediate] | |
961 | Re-try Boot [Disabled] | |
962 | Install Windows 7 USB support [Disabled] | |
963 | Port 61h Bit-4 Emulation [Disabled] | |
965 | Power Configuration | |
966 | Watch Dog Function [Disabled] | |
967 | Restore on AC Power Loss [Last State] | |
968 | Power Button Function [Instant Off] | |
969 | Throttle on Power Fail [Disabled] | |
972 #### CPU Configuration
974 | Processor Configuration |Enables Hyper Threading |
975 | -------------------------------------------------- |(Software Method to |
976 | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical |
977 | Processor Socket CPU1 | CPU2 |Processor threads. |
978 | Processor ID 00050654* | 000506... | |
979 | Processor Frequency 2.500GHz | 2.500GHz | |
980 | Processor Max Ratio 19H | 19H | |
981 | Processor Min Ratio 0AH | 0AH | |
982 | Microcode Revision 02000030 | |
983 | L1 Cache RAM 64KB | 64KB | |
984 | L2 Cache RAM 1024KB | 1024KB | |
985 | L3 Cache RAM 39424KB | 39424KB | |
986 | Processor 0 Version | |
987 | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
988 | Processor 1 Version | |
989 | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
991 | Hyper-Threading [ALL] [Enable] | |
992 | Core Disable Bitmap(Hex) 0 | |
993 | Execute Disable Bit [Enable] | |
994 | Intel Virtualization Technology [Enable] | |
995 | PPIN Control [Unlock/Enable] | |
996 | Hardware Prefetcher [Enable] | |
997 | Adjacent Cache Prefetch [Enable] | |
998 | DCU Streamer Prefetcher [Enable] | |
999 | DCU IP Prefetcher [Enable] | |
1000 | LLC Prefetch [Disable] | |
1001 | Extended APIC [Disable] | |
1002 | AES-NI [Enable] | |
1003 |> Advanced Power Management Configuration | |
1006 ##### Advanced Power Management Configuration
1008 | Advanced Power Management Configuration |Switch CPU Power Management |
1009 | -------------------------------------------------- |profile |
1010 | Power Technology [Custom] | |
1011 | Power Performance Tuning [BIOS Controls EPB] | |
1012 | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
1013 |> CPU P State Control | |
1014 |> Hardware PM State Control | |
1015 |> CPU C State Control | |
1016 |> Package C State Control | |
1017 |> CPU T State Control | |
1020 ###### CPU P State Control
1022 | CPU P State Control |Enable/Disable EIST |
1024 | SpeedStep (Pstates) [Disable] | |
1025 | EIST PSD Function [HW_ALL] | |
1028 ###### Hardware PM State Control
1030 | Hardware PM State Control |Disable: Hardware chooses a |
1031 | |P-state based on OS Request |
1032 | Hardware P-States [Disable] |(Legacy P-States) |
1033 | |Native Mode:Hardware |
1034 | |chooses a P-state based on |
1036 | |Out of Band Mode:Hardware |
1037 | |autonomously chooses a |
1038 | |P-state (no OS guidance) |
1041 ###### CPU C State Control
1043 | CPU C State Control |Autonomous Core C-State |
1045 | Autonomous Core C-State [Disable] | |
1046 | CPU C6 report [Disable] | |
1047 | Enhanced Halt State (C1E) [Disable] | |
1050 ###### Package C State Control
1052 | Package C State Control |Package C State limit |
1054 | Package C State [C0/C1 state] | |
1057 ###### CPU T State Control
1059 | CPU T State Control |Enable/Disable Software |
1060 | |Controlled T-States |
1061 | Software Controlled T-States [Disable] | |
1064 ##### Chipset Configuration
1066 | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
1067 | system to malfunction. | |
1074 |> UPI Configuration |Displays and provides |
1075 |> Memory Configuration |option to change the UPI |
1076 |> IIO Configuration |Settings |
1079 ###### UPI Configuration
1081 | UPI Configuration |Choose Topology Precedence |
1082 | -------------------------------------------------- |to degrade features if |
1083 | Number of CPU 2 |system options are in |
1084 | Number of Active UPI Link 3 |conflict or choose Feature |
1085 | Current UPI Link Speed Fast |Precedence to degrade |
1086 | Current UPI Link Frequency 10.4 GT/s |topology if system options |
1087 | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. |
1088 | UPI Global MMIO High Base / Limit 0000000000000000 / ... | |
1089 | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | |
1090 | Degrade Precedence [Topology Precedence] | |
1091 | Link L0p Enable [Disable] | |
1092 | Link L1 Enable [Disable] | |
1093 | IO Directory Cache (IODC) [Auto] | |
1095 | XPT Prefetch [Disable] | |
1096 | KTI Prefetch [Enable] | |
1097 | Local/Remote Threshold [Auto] | |
1098 | Stale AtoS [Disable] | |
1099 | LLC dead line alloc [Enable] | |
1100 | Isoc Mode [Auto] | |
1103 ###### Memory Configuration
1105 | |POR - Enforces Plan Of |
1106 | -------------------------------------------------- |Record restrictions for |
1107 | Integrated Memory Controller (iMC) |DDR4 frequency and voltage |
1108 | -------------------------------------------------- |programming. Disable - |
1109 | |Disables this feature. |
1110 | Enforce POR [Disable] | |
1111 | Memory Frequency [2666] | |
1112 | Data Scrambling for NVMDIMM [Auto] | |
1113 | Data Scrambling for DDR4 [Auto] | |
1114 | tCCD_L Relaxation [Auto] | |
1115 | Memory tRWSR Relaxation [Enable] | |
1116 | 2X REFRESH [Auto] | |
1117 | Page Policy [Auto] | |
1118 | IMC Interleaving [2-way Interleave] | |
1119 |> Memory Topology | |
1120 |> Memory RAS Configuration | |
1123 ###### IIO Configuration
1125 | IIO Configuration |Expose IIO DFX devices and |
1126 | -------------------------------------------------- |other CPU devices like PMON |
1128 | EV DFX Features [Disable] | |
1129 |> CPU1 Configuration | |
1130 |> CPU2 Configuration | |
1131 |> IOAT Configuration | |
1132 |> Intel. VT for Directed I/O (VT-d) | |
1133 |> Intel. VMD technology | |
1135 | IIO-PCIE Express Global Options | |
1136 | ======================================== | |
1137 | PCI-E Completion Timeout Disable [No] | |
1140 ###### CPU1 Configuration
1142 | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
1143 | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
1144 | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
1145 |> CPU1 SLOT2 PCI-E 3.0 X16 | |
1146 |> CPU1 SLOT4 PCI-E 3.0 X16 | |
1147 |> CPU1 SLOT9 PCI-E 3.0 X16 | |
1150 ###### CPU2 Configuration
1152 | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
1153 | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
1154 | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
1155 |> CPU2 SLOT6 PCI-E 3.0 X16 | |
1156 |> CPU2 SLOT8 PCI-E 3.0 X16 | |
1157 |> CPU2 SLOT10 PCI-E 3.0 X16 | |
1162 | |Enables Legacy USB support. |
1163 | USB Module Version 17 |AUTO option disables legacy |
1164 | |support if no USB devices |
1165 | USB Devices: |are connected. DISABLE |
1166 | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
1167 | |devices available only for |
1168 | Legacy USB Support [Enabled] |EFI applications. |
1169 | XHCI Hand-off [Disabled] | |
1170 | Port 60/64 Emulation [Enabled] | |
1171 | PCIe PLL SSC [Disable] | |
1172 | Real USB Wake Up [Enabled] | |
1173 | Front USB Wake Up [Enabled] | |
1176 | Azalia PME Enable [Disabled] | |
1179 #### PCIe/PCI/PnP Configuration
1181 | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit |
1182 | |capable Devices to be |
1183 | PCI Devices Common Settings: |Decoded in Above 4G Address |
1184 | Above 4G Decoding [Enabled] |Space (Only if System |
1185 | SR-IOV Support [Enabled] |Supports 64 bit PCI |
1186 | MMIO High Base [56T] |Decoding). |
1187 | MMIO High Granularity Size [256G] | |
1188 | Maximum Read Request [Auto] | |
1189 | MMCFG Base [2G] | |
1190 | NVMe Firmware Source [Vendor Defined Fi...] | |
1191 | VGA Priority [Onboard] | |
1192 | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | |
1193 | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | |
1194 | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | |
1195 | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | |
1196 | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | |
1197 | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | |
1198 | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | |
1199 | M.2 CONNECTOR OPROM [Legacy] | |
1200 | Onboard LAN1 Option ROM [Legacy] | |
1201 | Onboard LAN2 Option ROM [Disabled] | |
1202 | Onboard Video Option ROM [Legacy] | |
1203 |> Network Stack Configuration | |
1208 | ACPI Settings |Enable or Disable Non |
1209 | |uniform Memory Access |
1210 | NUMA [Enabled] |(NUMA). |
1211 | WHEA Support [Enabled] | |
1212 | High Precision Event Timer [Enabled] | |
1213 | ACPI Sleep State [S3 (Suspend to RAM)] | |
1219 Getting SMBIOS data from sysfs.
1220 SMBIOS 3.1.1 present.
1221 Table at 0x000E89C0.
1223 Handle 0x0000, DMI type 0, 26 bytes
1225 Vendor: American Megatrends Inc.
1227 Release Date: 11/29/2017
1234 BIOS shadowing is allowed
1235 Boot from CD is supported
1236 Selectable boot is supported
1237 BIOS ROM is socketed
1239 5.25"/1.2 MB floppy services are supported (int 13h)
1240 3.5"/720 kB floppy services are supported (int 13h)
1241 3.5"/2.88 MB floppy services are supported (int 13h)
1242 Print screen service is supported (int 5h)
1243 Serial services are supported (int 14h)
1244 Printer services are supported (int 17h)
1246 USB legacy is supported
1247 BIOS boot specification is supported
1248 Targeted content distribution is supported
1252 Handle 0x0001, DMI type 1, 27 bytes
1254 Manufacturer: Supermicro
1255 Product Name: SYS-7049GP-TRT
1257 Serial Number: S291427X8332242
1258 UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
1259 Wake-up Type: Power Switch
1260 SKU Number: To be filled by O.E.M.
1261 Family: To be filled by O.E.M.
1263 Handle 0x0002, DMI type 2, 15 bytes
1264 Base Board Information
1265 Manufacturer: Supermicro
1266 Product Name: X11DPG-QT
1268 Serial Number: VM183S014930
1269 Asset Tag: To be filled by O.E.M.
1271 Board is a hosting board
1272 Board is replaceable
1273 Location In Chassis: To be filled by O.E.M.
1274 Chassis Handle: 0x0003
1276 Contained Object Handles: 0
1278 Handle 0x0003, DMI type 3, 22 bytes
1280 Manufacturer: Supermicro
1284 Serial Number: C7470KH06A20167
1285 Asset Tag: To be filled by O.E.M.
1287 Power Supply State: Safe
1289 Security Status: None
1290 OEM Information: 0x00000000
1292 Handle 0x0050, DMI type 4, 48 bytes
1293 Processor Information
1294 Socket Designation: CPU1
1295 Type: Central Processor
1297 Manufacturer: Intel(R) Corporation
1298 ID: 54 06 05 00 FF FB EB BF
1299 Signature: Type 0, Family 6, Model 85, Stepping 4
1301 FPU (Floating-point unit on-chip)
1302 VME (Virtual mode extension)
1303 DE (Debugging extension)
1304 PSE (Page size extension)
1305 TSC (Time stamp counter)
1306 MSR (Model specific registers)
1307 PAE (Physical address extension)
1308 MCE (Machine check exception)
1309 CX8 (CMPXCHG8 instruction supported)
1310 APIC (On-chip APIC hardware supported)
1311 SEP (Fast system call)
1312 MTRR (Memory type range registers)
1313 PGE (Page global enable)
1314 MCA (Machine check architecture)
1315 CMOV (Conditional move instruction supported)
1316 PAT (Page attribute table)
1317 PSE-36 (36-bit page size extension)
1318 CLFSH (CLFLUSH instruction supported)
1320 ACPI (ACPI supported)
1321 MMX (MMX technology supported)
1322 FXSR (FXSAVE and FXSTOR instructions supported)
1323 SSE (Streaming SIMD extensions)
1324 SSE2 (Streaming SIMD extensions 2)
1326 HTT (Multi-threading)
1327 TM (Thermal monitor supported)
1328 PBE (Pending break enabled)
1329 Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
1331 External Clock: 100 MHz
1333 Current Speed: 2500 MHz
1334 Status: Populated, Enabled
1336 L1 Cache Handle: 0x004D
1337 L2 Cache Handle: 0x004E
1338 L3 Cache Handle: 0x004F
1339 Serial Number: Not Specified
1341 Part Number: Not Specified
1350 Enhanced Virtualization
1351 Power/Performance Control
1354 Handle 0x0054, DMI type 4, 48 bytes
1355 Processor Information
1356 Socket Designation: CPU2
1357 Type: Central Processor
1359 Manufacturer: Intel(R) Corporation
1360 ID: 54 06 05 00 FF FB EB BF
1361 Signature: Type 0, Family 6, Model 85, Stepping 4
1363 FPU (Floating-point unit on-chip)
1364 VME (Virtual mode extension)
1365 DE (Debugging extension)
1366 PSE (Page size extension)
1367 TSC (Time stamp counter)
1368 MSR (Model specific registers)
1369 PAE (Physical address extension)
1370 MCE (Machine check exception)
1371 CX8 (CMPXCHG8 instruction supported)
1372 APIC (On-chip APIC hardware supported)
1373 SEP (Fast system call)
1374 MTRR (Memory type range registers)
1375 PGE (Page global enable)
1376 MCA (Machine check architecture)
1377 CMOV (Conditional move instruction supported)
1378 PAT (Page attribute table)
1379 PSE-36 (36-bit page size extension)
1380 CLFSH (CLFLUSH instruction supported)
1382 ACPI (ACPI supported)
1383 MMX (MMX technology supported)
1384 FXSR (FXSAVE and FXSTOR instructions supported)
1385 SSE (Streaming SIMD extensions)
1386 SSE2 (Streaming SIMD extensions 2)
1388 HTT (Multi-threading)
1389 TM (Thermal monitor supported)
1390 PBE (Pending break enabled)
1391 Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
1393 External Clock: 100 MHz
1395 Current Speed: 2500 MHz
1396 Status: Populated, Enabled
1398 L1 Cache Handle: 0x0051
1399 L2 Cache Handle: 0x0052
1400 L3 Cache Handle: 0x0053
1401 Serial Number: Not Specified
1403 Part Number: Not Specified
1412 Enhanced Virtualization
1413 Power/Performance Control
1416 ### Xeon Skx Server Firmware Inventory
1418 Host. IPMI IP. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e.
1419 s1-t11-sut1. 10.30.50.47. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1420 s2-t12-sut1. 10.30.50.48. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1421 s3-t21-sut1. 10.30.50.41. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1422 s4-t21-tg1. 10.30.50.42. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1423 s5-t22-sut1. 10.30.50.49. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1424 s6-t22-tg1. 10.30.50.50. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1425 s7-t23-sut1. 10.30.50.51. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1426 s8-t23-tg1. 10.30.50.52. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1427 s9-t24-sut1. 10.30.50.53. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1428 s10-t24-tg1. 10.30.50.54. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1429 s11-t31-sut1. 10.30.50.43. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1430 s12-t31-sut2. 10.30.50.44. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1431 s13-t31-tg1. 10.30.50.45. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1432 s14-t32-sut1. 10.30.50.55. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1433 s15-t32-sut2. 10.30.50.56. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1434 s16-t32-tg1. 10.30.50.57. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1435 s19-t33t34-tg1. 10.30.50.46. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.