1 ## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom
3 This is a low-level design implemented as an extensions of FD.io CSIT lab to
4 accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices.
8 ### Testbeds Type Breakdown
11 #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node.
12 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2.
13 2. 2-node Xeon. perf. skx. skx. 4. 4. 4. 8.
14 3. 3-node Xeon. perf. skx. skx. 2. 4. 2. 6.
15 4. tcp-l47. tcp-stack. skx. ps1. 1. 1. 1. 1.
16 5. atom-netgate. perf+func. net. skx. 1. 3. 1. 1.
17 6. aarch64-d05 perf arm. skx. 1. 2. 1. 1/2.
18 7. aarch64-mcbin perf arm. skx. 1. 2. 1. 1/2.
19 8. 1-node aarch64 func arm. n/a. 1. 1. 0. 0.
23 ### 1-Node Xeon Testbeds
25 One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6
26 server), with NIC ports connected back-to-back.
28 ### 2-Node Xeon Testbeds
30 Four 2-node Xeon testbeds (are expected to be built|are built), with each
31 testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected
32 back-to-back. NIC cards placement into slots and NIC ports connectivity is
33 following the testbed specification included in next sections.
35 ### 3-Node Xeon Testbeds
37 Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed
38 using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh
39 triangle. NIC cards placement into slots and NIC ports connectivity is following
40 the testbed specification included in next sections.
42 ### 1-Node Arm Marvell ThunderX2 Testbed
44 One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using
45 one SUT (Type-9 server), with NIC ports connected back-to-back.
47 ### 3-Node Arm Huawei TaiShan Testbed
49 One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3
50 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards
51 placement into slots and NIC ports connectivity is following the testbed
52 specification included in next sections.
54 ### 3-Node Arm Marvell MACCHIATObin Testbed
56 One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs
57 (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
58 Built-in NIC ports connectivity is following the testbed specification included
61 ### TCP/IP and L47 Testbeds
63 One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
66 One 3-node Atom (Netgate based) testbed is built consisting of three SUTs
67 (Type-5 Netgate device.) NIC cards placement into slots and NIC ports
68 connectivity is following the testbed specification included in the next
76 1. Ixia PerfectStorm One Appliance
79 - Motherboard: SuperMicro X11DPG-QT.
80 - Processors: Quad-Core, Intel Processor.
81 - HW accelerators: FPGA offload.
83 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
84 - Physical Interfaces: 4 * 10GE SFP+.
85 - Operating System: Native IxOS.
91 1. Arm Cortex A-72 servers
93 - Chassis: Marvell ThunderX2
94 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
95 - RAM Memory: 4* 32GB RDIMM
96 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
97 - 2 * Huawei TaiShan 2280.
98 - Chassis: Huawei TaiShan 2280.
99 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
100 - RAM Memory: 8* 16GB DDR4-2400MT/s.
101 - Disks: 1* 4TB SATA HDD.
103 - Chassis: MACCHIATObin.
104 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
105 - RAM Memory: 1* 16GB DDR4.
106 - Disks: 1* 128GB(?) SATA SDD.
109 Platform Name and Specification | Role | Status | Hostname | IP | IPMI | Cores | RAM | Ethernet | Distro
110 ------------------------------- | ---- | ------ | -------- | -- | ---- | ----- | --- | -------- | ------
111 [SoftIron OverDrive 1000](https://softiron.com/development-tools/overdrive-1000/) | CI build server | Up, Not Running Jobs | softiron-1 | 10.30.51.12 | N/A | 4 | 8GB | | openSUSE
112 | | CI build server | Up, Not Running Jobs | softiron-2 | 10.30.51.13 | N/A | 4 | 8GB | | openSUSE
113 | | CI build server | Up, Not Running Jobs | softiron-3 | 10.30.51.14 | N/A | 4 | 8GB | | openSUSE
114 [Marvell ThunderX](https://www.marvell.com/server-processors/thunderx-arm-processors/) | CI build server | Up, Running VPP CI | nomad3arm | 10.30.51.38 | 10.30.50.38 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
115 | | CI build server | Up, Running VPP CI | nomad4arm | 10.30.51.39 | 10.30.50.39 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
116 | | CI build server | Up, Running VPP CI | nomad5arm | 10.30.51.40 | 10.30.50.40 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
117 | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad6arm | 10.30.51.65 | 10.30.50.65 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
118 | | VPP dev debug | Up | nomad7arm | 10.30.51.66 | 10.30.50.66 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
119 | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad8arm | 10.30.51.67 | 10.30.50.67 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
120 | | VPP dev debug | Up | nomad9arm | 10.30.51.68 | 10.30.50.68 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
121 [Marvell ThunderX2](https://www.marvell.com/server-processors/thunderx2-arm-processors/) | VPP device server | Being Provisioned | s27-t13-sut1 | 10.30.51.69 | 10.30.50.69 | 112 | 128GB | 3x40GbE QSFP+ XL710-QDA2 | Ubuntu 18.04.1
122 Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-sut1 | 10.30.51.36 | 10.30.50.36 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
123 | | CSIT Performance | Up, Manual perf experiments | s18-t33-sut2 | 10.30.51.37 | 10.30.50.37 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
124 [Marvell MACCHIATObin](http://macchiatobin.net/) | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s20-t34-sut1 | 10.30.51.41 | 10.30.51.49, then connect to /dev/ttyUSB0 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.4
125 | | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s21-t34-sut2 | 10.30.51.42 | 10.30.51.49, then connect to /dev/ttyUSB1 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
126 | | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
128 ### Xeon and Atom Servers
131 1. Intel Xeon servers:
132 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
133 - Chassis: SuperMicro SYS-7049GP-TRT.
134 - Motherboard: SuperMicro X11DPG-QT.
135 - Processors: 2* Intel Platinum 8180 2.3 GHz.
136 - RAM Memory: 16* 16GB DDR4-2666MHz.
137 - Disks: 2* 1.6TB 6G SATA SSD.
138 2. Intel Atom servers with Rangely processors.
139 - 3 * Netgate XG-2758-1u
140 - Chassis: Netgate XG-2758-1u
141 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
142 - RAM Memory: 16GB ECC
146 ### Network Interface Cards
150 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
151 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
152 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
154 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
156 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
158 - 4 * mcx556a-edat NICs (not on site yet, in transit)
161 ### Pluggables and Cables
167 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
168 - 80 * 10G SR optic (generic, "Intel" compatible branded)
174 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
185 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
190 ### Other Network Cards
194 ## Installation Status
196 Lab installation status is tracked by LF IT team in
197 [FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
199 ## Server/Device Management and Naming
201 ### Server Management Requirements
203 Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
204 For management purposes, each server must have following two ports connected to
205 the management network:
209 - IPMI - Intelligent Platform Management Interface.
210 - Required for access to embedded server management with WebUI, CLI, SNMPv3,
211 IPMIv2.0, for firmware (BIOS) and OS updates.
212 - 1GE/10GE management port
213 - hostOS management port for general system management.
216 ### Server and Port Naming Convention
218 Following naming convention is used within this page to specify physical
219 connectivity and wiring across defined CSIT testbeds:
222 - testbedname: testbedN.
224 - traffic-generator: tN-tgW.
225 - system-under-testX: tN-sutX.
230 - N - testbed number.
231 - tgW - server acts as traffic-generator with W index.
232 - sutX - server acts as system-under-test with X index.
233 - Y - PCIe slot number denoting a NIC card number within the host.
234 - Y=2,4,9 - slots connected to NUMA node 0.
235 - Y=6,8,10 - slots connected to NUMA node 1.
236 - Z - port number on the NIC card.
239 ### Server Management - Addressing
241 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
242 port, which are connected to two different VLANs.
246 - Subnet: 10.30.50.0/24
247 - Gateway: 10.30.50.1
248 - Broadcast: 10.30.50.255
249 - DNS1: 199.204.44.24
250 - DNS2: 199.204.47.54
252 - Subnet: 10.30.51.0/24
253 - Gateway: 10.30.51.1
254 - Broadcast: 10.30.51.255
255 - DNS1: 199.204.44.24
256 - DNS2: 199.204.47.54
259 To access these hosts, an VPN connection is required.
261 ### LOM (IPMI) VLAN IP Addresses
264 ### Management VLAN IP Addresses
267 ## Testbeds Specification - Target Build
269 ### Server/Ports Naming, NIC Placement
273 Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and
274 ports indexed per following specification:
278 - testbedname: testbed11.
279 - hostname: s1-t11-sut1.
280 - IPMI IP: 10.30.50.47
281 - Host IP: 10.30.51.50
283 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
284 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
285 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
286 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
287 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
288 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
289 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
290 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
292 - testbedname: testbed12.
293 - hostname: s2-t12-sut1.
294 - IPMI IP: 10.30.50.48
295 - Host IP: 10.30.51.51
297 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
298 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
299 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
300 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
301 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
302 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
303 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
304 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
309 Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and
310 ports indexed per following specification:
314 - testbedname: testbed21.
315 - hostname: s3-t21-sut1.
316 - IPMI IP: 10.30.50.41
317 - Host IP: 10.30.51.44
319 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
320 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
321 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
322 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
323 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
324 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
325 - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
326 - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
328 - testbedname: testbed21.
329 - hostname: s4-t21-tg1.
330 - IPMI IP: 10.30.50.42
331 - Host IP: 10.30.51.45
333 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
334 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
335 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
336 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
337 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
338 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
339 - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
340 - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
342 - testbedname: testbed22.
343 - hostname: s5-t22-sut1.
344 - IPMI IP: 10.30.50.49
345 - Host IP: 10.30.51.52
347 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
348 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
349 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
350 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
351 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
352 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
353 - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
354 - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
356 - testbedname: testbed22.
357 - hostname: s6-t22-tg1.
358 - IPMI IP: 10.30.50.50
359 - Host IP: 10.30.51.53
361 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
362 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
363 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
364 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
365 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
366 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
367 - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
368 - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
370 - testbedname: testbed23.
371 - hostname: s7-t23-sut1.
372 - IPMI IP: 10.30.50.51
373 - Host IP: 10.30.51.54
375 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
376 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
377 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
378 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
379 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
380 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
381 - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
382 - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
384 - testbedname: testbed23.
385 - hostname: s8-t23-tg1.
386 - IPMI IP: 10.30.50.52
387 - Host IP: 10.30.51.55
389 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
390 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
391 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
392 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
393 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
394 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
395 - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
396 - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
398 - testbedname: testbed24.
399 - hostname: s9-t24-sut1.
400 - IPMI IP: 10.30.50.53
401 - Host IP: 10.30.51.56
403 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
404 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
405 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
406 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
407 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
408 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
409 - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
410 - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
412 - testbedname: testbed24.
413 - hostname: s10-t24-tg1.
414 - IPMI IP: 10.30.50.54
415 - Host IP: 10.30.51.57
417 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
418 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
419 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
420 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
421 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
422 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
423 - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
424 - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
429 Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and
430 ports indexed per following specification:
434 - testbedname: testbed31.
435 - hostname: s11-t31-sut1.
436 - IPMI IP: 10.30.50.43
437 - Host IP: 10.30.51.46
439 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
440 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
441 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
442 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
443 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
444 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
445 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
446 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
448 - testbedname: testbed31.
449 - hostname: s12-t31-sut2.
450 - IPMI IP: 10.30.50.44
451 - Host IP: 10.30.51.47
453 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
454 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
455 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
456 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
457 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
458 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
459 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
460 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
462 - testbedname: testbed31.
463 - hostname: s13-t31-tg1.
464 - IPMI IP: 10.30.50.45
465 - Host IP: 10.30.51.48
467 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
468 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
469 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
470 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
471 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
472 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
473 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
474 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
476 - testbedname: testbed32.
477 - hostname: s14-t32-sut1.
478 - IPMI IP: 10.30.50.55
479 - Host IP: 10.30.51.58
481 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
482 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
483 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
484 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
485 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
486 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
487 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
488 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
490 - testbedname: testbed32.
491 - hostname: s15-t32-sut2.
492 - IPMI IP: 10.30.50.56
493 - Host IP: 10.30.51.59
495 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
496 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
497 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
498 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
499 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
500 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
501 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
502 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
504 - testbedname: testbed32.
505 - hostname: s16-t32-tg1.
506 - IPMI IP: 10.30.50.57
507 - Host IP: 10.30.51.60
509 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
510 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
511 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
512 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
513 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
514 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
515 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
516 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
523 - testbedname: testbed13.
524 - hostname: s27-t13-sut1.
525 - IPMI IP: 10.30.50.69
526 - Host IP: 10.30.51.69
528 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
529 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
530 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
531 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
532 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
533 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
538 Note: Server19 (TG) is shared between testbed33 & testbed34
542 - testbedname: testbed33.
543 - hostname: s17-t33-sut1.
544 - IPMI IP: 10.30.50.36
545 - Host IP: 10.30.51.36
547 - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
548 - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
549 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
550 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
552 - testbedname: testbed33.
553 - hostname: s18-t33-sut2.
554 - IPMI IP: 10.30.50.37
555 - Host IP: 10.30.51.37
557 - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
558 - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
559 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
560 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
562 - testbednames: testbed33 and testbed34.
563 - hostname: s19-t33t34-tg1.
564 - IPMI IP: 10.30.50.46
565 - Host IP: 10.30.51.49
567 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
568 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
569 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
570 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
571 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
572 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
573 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
574 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
575 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
576 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
578 - testbedname: testbed34.
579 - hostname: s20-t34-sut1.
581 - Host IP: 10.30.51.41
583 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
584 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
586 - testbedname: testbed34.
587 - hostname: s21-t34-sut2.
589 - Host IP: 10.30.51.42
591 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
592 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
597 Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and
598 NIC cards and ports indexed per following specification:
602 - testbedname: testbed25.
603 - hostname: s25-t25-sut1.
604 - IPMI IP: 10.30.50.58
605 - Host IP: 10.30.51.61
607 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
608 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
609 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
610 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
612 - testbedname: testbed25.
613 - hostname: s26-t25-tg1.
614 - IPMI IP: 10.30.50.59
615 - Host IP: 10.30.51.62
617 - s26-t25-tg1-p1 - 10GE-port1.
618 - s26-t25-tg1-p2 - 10GE-port2.
619 - s26-t25-tg1-p3 - 10GE-port3.
620 - s26-t25-tg1-p4 - 10GE-port4.
625 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
629 - testbedname: testbed35.
630 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
631 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
632 - Host IP: 10.30.51.9
634 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
635 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
638 - testbedname: testbed35.
639 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
640 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
641 - Host IP: 10.30.51.10
643 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
644 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
647 - testbedname: testbed35.
648 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
649 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
650 - Host IP: 10.30.51.11
652 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
653 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
657 ### Physical Connectivity within Testbeds
661 Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below
666 - ring1 10GE-ports x710-4p10GE:
667 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
668 - ring2 10GE-ports x710-4p10GE:
669 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
670 - ring3 10GE-ports x710-4p10GE:
671 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
672 - ring4 10GE-ports x710-4p10GE:
673 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
675 - ring1 10GE-ports x710-4p10GE:
676 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
677 - ring2 10GE-ports x710-4p10GE:
678 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
679 - ring3 10GE-ports x710-4p10GE:
680 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
681 - ring4 10GE-ports x710-4p10GE:
682 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
687 Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below
692 - ring1 10GE-ports x710-4p10GE on SUT:
693 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
694 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
695 - ring2 10GE-ports x710-4p10GE on SUT:
696 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
697 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
698 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
699 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
700 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
701 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
702 - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
703 - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
704 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
705 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
706 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
708 - ring1 10GE-ports x710-4p10GE on SUT:
709 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
710 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
711 - ring2 10GE-ports x710-4p10GE on SUT:
712 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
713 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
714 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
715 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
716 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
717 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
718 - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
719 - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
720 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
721 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
722 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
724 - ring1 10GE-ports x710-4p10GE on SUT:
725 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
726 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
727 - ring2 10GE-ports x710-4p10GE on SUT:
728 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
729 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
730 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
731 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
732 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
733 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
734 - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
735 - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
736 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
737 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
738 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
740 - ring1 10GE-ports x710-4p10GE on SUT:
741 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
742 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
743 - ring2 10GE-ports x710-4p10GE on SUT:
744 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
745 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
746 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
747 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
748 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
749 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
750 - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
751 - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
752 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
753 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
754 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
759 Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below
764 - ring1 10GE-ports x710-4p10GE on SUTs:
765 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
766 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
767 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
768 - ring2 10GE-ports x710-4p10GE on SUT:
769 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
770 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
771 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
772 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
773 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
774 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
775 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
776 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
777 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
778 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
779 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
780 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
781 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
782 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
784 - ring1 10GE-ports x710-4p10GE on SUTs:
785 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
786 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
787 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
788 - ring2 10GE-ports x710-4p10GE on SUT:
789 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
790 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
791 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
792 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
793 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
794 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
795 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
796 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
797 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
798 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
799 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
800 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
801 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
802 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
808 One 1-Node testbed is constructed by connecting 1 Arm server using below
813 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
814 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
815 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
816 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
817 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
818 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
823 One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon
824 server using below specification:
828 - ring1 10GE-ports 82599-2p10GE on SUTs:
829 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
830 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
831 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
832 - ring2 25GE-ports cx4-2p25GE on SUTs:
833 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
834 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
835 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
838 One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one
839 Xeon server using below specification:
843 - ring1 10GE-ports Marvell on SUTs:
844 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
845 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
846 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
851 One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon
852 server using below specification:
856 - link1 10GE-port x710-4p10GE on SUT:
857 - t25-tg1-p1 to t25-sut1-c2/p1.
858 - link2 10GE-port x710-4p10GE on SUT:
859 - t25-tg1-p2 to t25-sut1-c2/p2.
860 - link3 10GE-port x710-4p10GE on SUT:
861 - t25-tg1-p3 to t25-sut1-c2/p3.
862 - link4 10GE-port x710-4p10GE on SUT:
863 - t25-tg1-p4 to t25-sut1-c2/p4.
870 ## Server Specification
872 ### Hardware Configuration
874 The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
875 server configurations:
878 1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e.
880 - Quantity: TBD based on testbed allocation.
881 - Physical connectivity:
882 - IPMI and host management ports.
883 - NIC ports connected into 2-node and 3-node topologies.
884 - Main HW configuration:
885 - Chassis: SuperMicro SYS-7049GP-TRT.
886 - Motherboard: SuperMicro X11DPG-QT.
887 - Processors: 2* Intel Platinum 8180 2.3 GHz.
888 - RAM Memory: 16* 16GB DDR4-2666MHz.
889 - Disks: 2* 1.6TB 6G SATA SSD.
890 - NICs configuration:
891 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
892 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
893 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
894 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
895 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
896 - PCIe Slot6 86:00.xx: empty.
897 - PCIe Slot8 af:00.xx: empty.
898 - PCIe Slot10 d8:00.xx: empty.
899 2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
900 - Quantity: TBD based on testbed allocation.
901 - Physical connectivity:
902 - IPMI and host management ports.
903 - NIC ports connected into 2-node and 3-node topologies.
904 - Main HW configuration:
905 - Chassis: SuperMicro SYS-7049GP-TRT.
906 - Motherboard: SuperMicro X11DPG-QT.
907 - Processors: 2* Intel Platinum 8180 2.3 GHz.
908 - RAM Memory: 16* 16GB DDR4-2666MHz.
909 - Disks: 2* 1.6TB 6G SATA SSD.
910 - NICs configuration:
911 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
912 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
913 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
914 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
915 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
916 - PCIe Slot6 86:00.xx: empty.
917 - PCIe Slot8 af:00.xx: empty.
918 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
919 3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload
922 - Physical connectivity:
923 - IPMI(?) and host management ports.
924 - NIC ports connected into 3-node topology.
925 - Main HW configuration:
926 - Chassis: Huawei TaiShan 2280.
927 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
928 - RAM Memory: 8* 16GB DDR4-2400MT/s
929 - Disks: 1* 4TB SATA HDD
930 - NICs configuration:
931 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
932 - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
933 4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload
936 - Physical connectivity:
937 - Host management ports.
938 - NIC ports connected into 2-node and 3-node topologies.
939 - Main HW configuration:
940 - Chassis: MACCHIATObin.
941 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
942 - RAM Memory: 1* 16GB DDR4
943 - Disks: 1* 128GB(?) SATA SDD
944 - NICs configuration:
945 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
946 5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e.
948 - Quantity: TBD based on testbed allocation.
949 - Physical connectivity:
950 - Management: serial Port (usb) for console
951 - NIC ports connected into 2-node.
952 - Main HW configuration:
953 - Chassis: Netgate XG-2758-1u
954 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
955 - RAM Memory: 16GB ECC
957 - NICs configuration:
958 - 2x 10Gb Intel 82599ES
960 6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
962 - Physical connectivity:
963 - IPMI and host management ports.
964 - NIC ports connected into 2-node and 3-node topologies.
965 - Main HW configuration:
966 - Chassis: SuperMicro SYS-7049GP-TRT.
967 - Motherboard: SuperMicro X11DPG-QT.
968 - Processors: 2* Intel Platinum 8180 2.3 GHz.
969 - RAM Memory: 16* 16GB DDR4-2666MHz.
970 - Disks: 2* 1.6TB 6G SATA SSD.
971 - NICs configuration:
972 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
973 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
974 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
975 - PCIe Slot9 5e:00.xx: empty.
976 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
977 - PCIe Slot6 86:00.xx: empty.
978 - PCIe Slot8 af:00.xx: empty.
979 - PCIe Slot10 d8:00.xx: empty.
980 7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance
983 - Physical connectivity:
984 - Host management interface: 10/100/1000-BaseT.
985 - 8-port 10GE SFP+ integrated NIC.
986 - Main HW configuration:
987 - Chassis: PS10GE4NG.
988 - Motherboard: SuperMicro X11DPG-QT.
989 - Processors: Quad-Core, Intel Processor.
990 - HW accelerators: FPGA offload.
992 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
993 - Physical Interfaces: 4 * 10GE SFP+.
994 - Operating System: Native IxOS.
995 - Interface configuration:
1000 8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
1002 - Physical connectivity:
1003 - IPMI and host management ports.
1005 - Main HW configuration:
1006 - Chassis: SuperMicro SYS-7049GP-TRT.
1007 - Motherboard: SuperMicro X11DPG-QT.
1008 - Processors: 2* Intel Platinum 8180 2.3 GHz.
1009 - RAM Memory: 16* 16GB DDR4-2666MHz.
1010 - Disks: 2* 1.6TB 6G SATA SSD.
1011 - NICs configuration:
1012 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
1013 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
1014 - PCIe Slot4 3b:00.xx: empty.
1015 - PCIe Slot9 5e:00.xx: empty.
1016 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
1017 - PCIe Slot6 86:00.xx: empty.
1018 - PCIe Slot8 af:00.xx: empty.
1019 - PCIe Slot10 d8:00.xx: empty.
1020 9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional
1023 - Physical connectivity:
1024 - IPMI and host management ports.
1025 - NIC ports connected into 1-node topologies.
1026 - Main HW configuration:
1027 - Chassis: Gigabyte R181-T90 1U
1028 - Motheboard: MT91-FS1
1029 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
1030 - RAM Memory: 4* 32GB RDIMM
1031 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1032 - NICs configuration:
1034 - PCIe Slot1 05:00.xx: XL710-QDA2.
1035 - PCIe Slot3 08:00.xx: XL710-QDA2.
1037 - PCIe Slot6 85:00.xx: XL710-QDA2.
1038 10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane
1039 Workload i.e. VPP, testpmd.
1041 - Physical connectivity:
1042 - IPMI and host management ports.
1044 - Main HW configuration:
1045 - Chassis: SuperMicro SYS-E300-9A
1046 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
1047 - RAM Memory: 32GB ECC
1049 - NICs configuration:
1050 - 2x 10Gb Intel x553 fiber ports
1051 - 2x 10Gb Intel x553 copper ports
1052 - 4x 1GB Intel I350 ports
1055 ### Xeon Skx Server BIOS Configuration
1060 | Quiet Boot [Enabled] |Boot option |
1062 | Option ROM Messages [Force BIOS] | |
1063 | Bootup NumLock State [On] | |
1064 | Wait For "F1" If Error [Enabled] | |
1065 | INT19 Trap Response [Immediate] | |
1066 | Re-try Boot [Disabled] | |
1067 | Install Windows 7 USB support [Disabled] | |
1068 | Port 61h Bit-4 Emulation [Disabled] | |
1070 | Power Configuration | |
1071 | Watch Dog Function [Disabled] | |
1072 | Restore on AC Power Loss [Last State] | |
1073 | Power Button Function [Instant Off] | |
1074 | Throttle on Power Fail [Disabled] | |
1077 #### CPU Configuration
1080 | Processor Configuration |Enables Hyper Threading |
1081 | -------------------------------------------------- |(Software Method to |
1082 | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical |
1083 | Processor Socket CPU1 | CPU2 |Processor threads. |
1084 | Processor ID 00050654* | 000506... | |
1085 | Processor Frequency 2.500GHz | 2.500GHz | |
1086 | Processor Max Ratio 19H | 19H | |
1087 | Processor Min Ratio 0AH | 0AH | |
1088 | Microcode Revision 02000030 | |
1089 | L1 Cache RAM 64KB | 64KB | |
1090 | L2 Cache RAM 1024KB | 1024KB | |
1091 | L3 Cache RAM 39424KB | 39424KB | |
1092 | Processor 0 Version | |
1093 | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
1094 | Processor 1 Version | |
1095 | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
1097 | Hyper-Threading [ALL] [Enable] | |
1098 | Core Disable Bitmap(Hex) 0 | |
1099 | Execute Disable Bit [Enable] | |
1100 | Intel Virtualization Technology [Enable] | |
1101 | PPIN Control [Unlock/Enable] | |
1102 | Hardware Prefetcher [Enable] | |
1103 | Adjacent Cache Prefetch [Enable] | |
1104 | DCU Streamer Prefetcher [Enable] | |
1105 | DCU IP Prefetcher [Enable] | |
1106 | LLC Prefetch [Disable] | |
1107 | Extended APIC [Disable] | |
1108 | AES-NI [Enable] | |
1109 |> Advanced Power Management Configuration | |
1112 ##### Advanced Power Management Configuration
1115 | Advanced Power Management Configuration |Switch CPU Power Management |
1116 | -------------------------------------------------- |profile |
1117 | Power Technology [Custom] | |
1118 | Power Performance Tuning [BIOS Controls EPB] | |
1119 | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
1120 |> CPU P State Control | |
1121 |> Hardware PM State Control | |
1122 |> CPU C State Control | |
1123 |> Package C State Control | |
1124 |> CPU T State Control | |
1127 ###### CPU P State Control
1130 | CPU P State Control |Enable/Disable EIST |
1132 | SpeedStep (Pstates) [Disable] | |
1133 | EIST PSD Function [HW_ALL] | |
1136 ###### Hardware PM State Control
1139 | Hardware PM State Control |Disable: Hardware chooses a |
1140 | |P-state based on OS Request |
1141 | Hardware P-States [Disable] |(Legacy P-States) |
1142 | |Native Mode:Hardware |
1143 | |chooses a P-state based on |
1145 | |Out of Band Mode:Hardware |
1146 | |autonomously chooses a |
1147 | |P-state (no OS guidance) |
1150 ###### CPU C State Control
1153 | CPU C State Control |Autonomous Core C-State |
1155 | Autonomous Core C-State [Disable] | |
1156 | CPU C6 report [Disable] | |
1157 | Enhanced Halt State (C1E) [Disable] | |
1160 ###### Package C State Control
1163 | Package C State Control |Package C State limit |
1165 | Package C State [C0/C1 state] | |
1168 ###### CPU T State Control
1171 | CPU T State Control |Enable/Disable Software |
1172 | |Controlled T-States |
1173 | Software Controlled T-States [Disable] | |
1176 ##### Chipset Configuration
1179 | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
1180 | system to malfunction. | |
1188 |> UPI Configuration |Displays and provides |
1189 |> Memory Configuration |option to change the UPI |
1190 |> IIO Configuration |Settings |
1193 ###### UPI Configuration
1196 | UPI Configuration |Choose Topology Precedence |
1197 | -------------------------------------------------- |to degrade features if |
1198 | Number of CPU 2 |system options are in |
1199 | Number of Active UPI Link 3 |conflict or choose Feature |
1200 | Current UPI Link Speed Fast |Precedence to degrade |
1201 | Current UPI Link Frequency 10.4 GT/s |topology if system options |
1202 | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. |
1203 | UPI Global MMIO High Base / Limit 0000000000000000 / ... | |
1204 | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | |
1205 | Degrade Precedence [Topology Precedence] | |
1206 | Link L0p Enable [Disable] | |
1207 | Link L1 Enable [Disable] | |
1208 | IO Directory Cache (IODC) [Auto] | |
1210 | XPT Prefetch [Disable] | |
1211 | KTI Prefetch [Enable] | |
1212 | Local/Remote Threshold [Auto] | |
1213 | Stale AtoS [Disable] | |
1214 | LLC dead line alloc [Enable] | |
1215 | Isoc Mode [Auto] | |
1218 ###### Memory Configuration
1221 | |POR - Enforces Plan Of |
1222 | -------------------------------------------------- |Record restrictions for |
1223 | Integrated Memory Controller (iMC) |DDR4 frequency and voltage |
1224 | -------------------------------------------------- |programming. Disable - |
1225 | |Disables this feature. |
1226 | Enforce POR [Disable] | |
1227 | Memory Frequency [2666] | |
1228 | Data Scrambling for NVMDIMM [Auto] | |
1229 | Data Scrambling for DDR4 [Auto] | |
1230 | tCCD_L Relaxation [Auto] | |
1231 | Memory tRWSR Relaxation [Enable] | |
1232 | 2X REFRESH [Auto] | |
1233 | Page Policy [Auto] | |
1234 | IMC Interleaving [2-way Interleave] | |
1235 |> Memory Topology | |
1236 |> Memory RAS Configuration | |
1239 ###### IIO Configuration
1242 | IIO Configuration |Expose IIO DFX devices and |
1243 | -------------------------------------------------- |other CPU devices like PMON |
1245 | EV DFX Features [Disable] | |
1246 |> CPU1 Configuration | |
1247 |> CPU2 Configuration | |
1248 |> IOAT Configuration | |
1249 |> Intel. VT for Directed I/O (VT-d) | |
1250 |> Intel. VMD technology | |
1252 | IIO-PCIE Express Global Options | |
1253 | ======================================== | |
1254 | PCI-E Completion Timeout Disable [No] | |
1257 ###### CPU1 Configuration
1260 | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
1261 | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
1262 | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
1263 |> CPU1 SLOT2 PCI-E 3.0 X16 | |
1264 |> CPU1 SLOT4 PCI-E 3.0 X16 | |
1265 |> CPU1 SLOT9 PCI-E 3.0 X16 | |
1268 ###### CPU2 Configuration
1271 | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
1272 | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
1273 | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
1274 |> CPU2 SLOT6 PCI-E 3.0 X16 | |
1275 |> CPU2 SLOT8 PCI-E 3.0 X16 | |
1276 |> CPU2 SLOT10 PCI-E 3.0 X16 | |
1282 | |Enables Legacy USB support. |
1283 | USB Module Version 17 |AUTO option disables legacy |
1284 | |support if no USB devices |
1285 | USB Devices: |are connected. DISABLE |
1286 | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
1287 | |devices available only for |
1288 | Legacy USB Support [Enabled] |EFI applications. |
1289 | XHCI Hand-off [Disabled] | |
1290 | Port 60/64 Emulation [Enabled] | |
1291 | PCIe PLL SSC [Disable] | |
1292 | Real USB Wake Up [Enabled] | |
1293 | Front USB Wake Up [Enabled] | |
1296 | Azalia PME Enable [Disabled] | |
1299 #### PCIe/PCI/PnP Configuration
1302 | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit |
1303 | |capable Devices to be |
1304 | PCI Devices Common Settings: |Decoded in Above 4G Address |
1305 | Above 4G Decoding [Enabled] |Space (Only if System |
1306 | SR-IOV Support [Enabled] |Supports 64 bit PCI |
1307 | MMIO High Base [56T] |Decoding). |
1308 | MMIO High Granularity Size [256G] | |
1309 | Maximum Read Request [Auto] | |
1310 | MMCFG Base [2G] | |
1311 | NVMe Firmware Source [Vendor Defined Fi...] | |
1312 | VGA Priority [Onboard] | |
1313 | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | |
1314 | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | |
1315 | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | |
1316 | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | |
1317 | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | |
1318 | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | |
1319 | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | |
1320 | M.2 CONNECTOR OPROM [Legacy] | |
1321 | Onboard LAN1 Option ROM [Legacy] | |
1322 | Onboard LAN2 Option ROM [Disabled] | |
1323 | Onboard Video Option ROM [Legacy] | |
1324 |> Network Stack Configuration | |
1330 | ACPI Settings |Enable or Disable Non |
1331 | |uniform Memory Access |
1332 | NUMA [Enabled] |(NUMA). |
1333 | WHEA Support [Enabled] | |
1334 | High Precision Event Timer [Enabled] | |
1335 | ACPI Sleep State [S3 (Suspend to RAM)] | |
1342 Getting SMBIOS data from sysfs.
1343 SMBIOS 3.1.1 present.
1344 Table at 0x000E89C0.
1346 Handle 0x0000, DMI type 0, 26 bytes
1348 Vendor: American Megatrends Inc.
1350 Release Date: 11/29/2017
1357 BIOS shadowing is allowed
1358 Boot from CD is supported
1359 Selectable boot is supported
1360 BIOS ROM is socketed
1362 5.25"/1.2 MB floppy services are supported (int 13h)
1363 3.5"/720 kB floppy services are supported (int 13h)
1364 3.5"/2.88 MB floppy services are supported (int 13h)
1365 Print screen service is supported (int 5h)
1366 Serial services are supported (int 14h)
1367 Printer services are supported (int 17h)
1369 USB legacy is supported
1370 BIOS boot specification is supported
1371 Targeted content distribution is supported
1375 Handle 0x0001, DMI type 1, 27 bytes
1377 Manufacturer: Supermicro
1378 Product Name: SYS-7049GP-TRT
1380 Serial Number: S291427X8332242
1381 UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
1382 Wake-up Type: Power Switch
1383 SKU Number: To be filled by O.E.M.
1384 Family: To be filled by O.E.M.
1386 Handle 0x0002, DMI type 2, 15 bytes
1387 Base Board Information
1388 Manufacturer: Supermicro
1389 Product Name: X11DPG-QT
1391 Serial Number: VM183S014930
1392 Asset Tag: To be filled by O.E.M.
1394 Board is a hosting board
1395 Board is replaceable
1396 Location In Chassis: To be filled by O.E.M.
1397 Chassis Handle: 0x0003
1399 Contained Object Handles: 0
1401 Handle 0x0003, DMI type 3, 22 bytes
1403 Manufacturer: Supermicro
1407 Serial Number: C7470KH06A20167
1408 Asset Tag: To be filled by O.E.M.
1410 Power Supply State: Safe
1412 Security Status: None
1413 OEM Information: 0x00000000
1415 Handle 0x0050, DMI type 4, 48 bytes
1416 Processor Information
1417 Socket Designation: CPU1
1418 Type: Central Processor
1420 Manufacturer: Intel(R) Corporation
1421 ID: 54 06 05 00 FF FB EB BF
1422 Signature: Type 0, Family 6, Model 85, Stepping 4
1424 FPU (Floating-point unit on-chip)
1425 VME (Virtual mode extension)
1426 DE (Debugging extension)
1427 PSE (Page size extension)
1428 TSC (Time stamp counter)
1429 MSR (Model specific registers)
1430 PAE (Physical address extension)
1431 MCE (Machine check exception)
1432 CX8 (CMPXCHG8 instruction supported)
1433 APIC (On-chip APIC hardware supported)
1434 SEP (Fast system call)
1435 MTRR (Memory type range registers)
1436 PGE (Page global enable)
1437 MCA (Machine check architecture)
1438 CMOV (Conditional move instruction supported)
1439 PAT (Page attribute table)
1440 PSE-36 (36-bit page size extension)
1441 CLFSH (CLFLUSH instruction supported)
1443 ACPI (ACPI supported)
1444 MMX (MMX technology supported)
1445 FXSR (FXSAVE and FXSTOR instructions supported)
1446 SSE (Streaming SIMD extensions)
1447 SSE2 (Streaming SIMD extensions 2)
1449 HTT (Multi-threading)
1450 TM (Thermal monitor supported)
1451 PBE (Pending break enabled)
1452 Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
1454 External Clock: 100 MHz
1456 Current Speed: 2500 MHz
1457 Status: Populated, Enabled
1459 L1 Cache Handle: 0x004D
1460 L2 Cache Handle: 0x004E
1461 L3 Cache Handle: 0x004F
1462 Serial Number: Not Specified
1464 Part Number: Not Specified
1473 Enhanced Virtualization
1474 Power/Performance Control
1477 Handle 0x0054, DMI type 4, 48 bytes
1478 Processor Information
1479 Socket Designation: CPU2
1480 Type: Central Processor
1482 Manufacturer: Intel(R) Corporation
1483 ID: 54 06 05 00 FF FB EB BF
1484 Signature: Type 0, Family 6, Model 85, Stepping 4
1486 FPU (Floating-point unit on-chip)
1487 VME (Virtual mode extension)
1488 DE (Debugging extension)
1489 PSE (Page size extension)
1490 TSC (Time stamp counter)
1491 MSR (Model specific registers)
1492 PAE (Physical address extension)
1493 MCE (Machine check exception)
1494 CX8 (CMPXCHG8 instruction supported)
1495 APIC (On-chip APIC hardware supported)
1496 SEP (Fast system call)
1497 MTRR (Memory type range registers)
1498 PGE (Page global enable)
1499 MCA (Machine check architecture)
1500 CMOV (Conditional move instruction supported)
1501 PAT (Page attribute table)
1502 PSE-36 (36-bit page size extension)
1503 CLFSH (CLFLUSH instruction supported)
1505 ACPI (ACPI supported)
1506 MMX (MMX technology supported)
1507 FXSR (FXSAVE and FXSTOR instructions supported)
1508 SSE (Streaming SIMD extensions)
1509 SSE2 (Streaming SIMD extensions 2)
1511 HTT (Multi-threading)
1512 TM (Thermal monitor supported)
1513 PBE (Pending break enabled)
1514 Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
1516 External Clock: 100 MHz
1518 Current Speed: 2500 MHz
1519 Status: Populated, Enabled
1521 L1 Cache Handle: 0x0051
1522 L2 Cache Handle: 0x0052
1523 L3 Cache Handle: 0x0053
1524 Serial Number: Not Specified
1526 Part Number: Not Specified
1535 Enhanced Virtualization
1536 Power/Performance Control
1539 ### Xeon Skx Server Firmware Inventory
1542 Host. IPMI IP. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e.
1543 s1-t11-sut1. 10.30.50.47. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1544 s2-t12-sut1. 10.30.50.48. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1545 s3-t21-sut1. 10.30.50.41. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1546 s4-t21-tg1. 10.30.50.42. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1547 s5-t22-sut1. 10.30.50.49. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1548 s6-t22-tg1. 10.30.50.50. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1549 s7-t23-sut1. 10.30.50.51. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1550 s8-t23-tg1. 10.30.50.52. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1551 s9-t24-sut1. 10.30.50.53. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1552 s10-t24-tg1. 10.30.50.54. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1553 s11-t31-sut1. 10.30.50.43. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1554 s12-t31-sut2. 10.30.50.44. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1555 s13-t31-tg1. 10.30.50.45. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1556 s14-t32-sut1. 10.30.50.55. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1557 s15-t32-sut2. 10.30.50.56. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1558 s16-t32-tg1. 10.30.50.57. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1559 s19-t33t34-tg1. 10.30.50.46. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.