1 ## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom
2 This is a low-level design implemented as an extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. Content has been copied from [FD.io CSIT testbeds wiki page: Xeon_skx, Arm, Atom](https://wiki.fd.io/view/CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom).
5 ### Testbeds Type Breakdown
7 #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node.
8 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2.
9 2. 2-node Xeon. perf. skx. skx. 4. 4. 4. 8.
10 3. 3-node Xeon. perf. skx. skx. 2. 4. 2. 6.
11 4. tcp-l47. tcp-stack. skx. ps1. 1. 1. 1. 1.
12 5. atom-netgate. perf+func. net. skx. 1. 3. 1. 1.
13 6. aarch64-d05 perf+func. arm. skx. 2. 2. 1. 1.
14 7. aarch64-mcbin perf arm. skx. 1. 2. 1. 1.
18 ### 1-Node Xeon Testbeds
19 One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back.
21 ### 2-Node Xeon Testbeds
22 Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
24 ### 3-Node Xeon Testbeds
25 Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
28 One 3-node Huawei testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle.
30 One 3-node Marvell testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
32 ### TCP/IP and L47 Testbeds
33 One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
36 One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section.
41 1. Ixia PerfectStorm One Appliance
44 - Motherboard: SuperMicro X11DPG-QT.
45 - Processors: Quad-Core, Intel Processor.
46 - HW accelerators: FPGA offload.
48 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
49 - Physical Interfaces: 4 * 10GE SFP+.
50 - Operating System: Native IxOS.
55 1. Arm Cortex A-72 servers
56 - 2 * Huawei TaiShan 2280.
57 - Chassis: Huawei TaiShan 2280.
58 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
59 - RAM Memory: 8* 16GB DDR4-2400MT/s.
60 - Disks: 1* 4TB SATA HDD.
62 - Chassis: MACCHIATObin.
63 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
64 - RAM Memory: 1* 16GB DDR4.
65 - Disks: 1* 128GB(?) SATA SDD.
68 Platform Name and Specification | Role | Status | Hostname | IP | IPMI | Cores | RAM | Ethernet | Distro
69 ------------------------------- | ---- | ------ | -------- | -- | ---- | ----- | --- | -------- | ------
70 [SoftIron OverDrive 1000](https://softiron.com/development-tools/overdrive-1000/) | CI build server | Up, Not Running Jobs | softiron-1 | 10.30.51.12 | N/A | 4 | 8GB | | openSUSE
71 | CI build server | Up, Not Running Jobs | softiron-2 | 10.30.51.13 | N/A | 4 | 8GB | | openSUSE
72 | CI build server | Up, Not Running Jobs | softiron-3 | 10.30.51.14 | N/A | 4 | 8GB | | openSUSE
73 [Cavium ThunderX](https://cavium.com/product-thunderx-arm-processors.html) | CI build server | Up, Running VPP CI | nomad3arm | 10.30.51.38 | 10.30.50.38 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
74 | CI build server | Up, Running VPP CI | nomad4arm | 10.30.51.39 | 10.30.50.39 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
75 | CI build server | Up, Running VPP CI | nomad5arm | 10.30.51.40 | 10.30.50.40 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
76 | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | fdio-cavium4 | 10.30.51.65 | 10.30.50.65 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
77 | VPP dev debug | Up | fdio-cavium5 | 10.30.51.66 | 10.30.50.66 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
78 | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | fdio-cavium6 | 10.30.51.67 | 10.30.50.67 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
79 | VPP dev debug | Up | fdio-cavium7 | 10.30.51.68 | 10.30.50.68 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
80 Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s15-t33-sut1 | 10.30.51.36 | 10.30.50.36 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
81 | CSIT Performance | Up, Manual perf experiments | s16-t33-sut2 | 10.30.51.37 | 10.30.50.37 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
82 [Marvell MACCHIATObin](http://macchiatobin.net/) | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s20-t34-sut1 | 10.30.51.41 | 10.30.51.49, then connect to /dev/ttyUSB0 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.4
83 | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s21-t34-sut2 | 10.30.51.42 | 10.30.51.49, then connect to /dev/ttyUSB1 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
84 | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
86 ### Xeon and Atom Servers
88 1. Intel Xeon servers:
89 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
90 - Chassis: SuperMicro SYS-7049GP-TRT.
91 - Motherboard: SuperMicro X11DPG-QT.
92 - Processors: 2* Intel Platinum 8180 2.3 GHz.
93 - RAM Memory: 16* 16GB DDR4-2666MHz.
94 - Disks: 2* 1.6TB 6G SATA SSD.
95 2. Intel Atom servers with Rangely processors.
96 - 3 * Netgate XG-2758-1u
97 - Chassis: Netgate XG-2758-1u
98 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
99 - RAM Memory: 16GB ECC
103 ### Network Interface Cards
106 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
107 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
108 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
110 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
112 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
114 - 4 * mcx556a-edat NICs (not on site yet, in transit)
117 ### Pluggables and Cables
121 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
122 - 80 * 10G SR optic (generic, "Intel" compatible branded)
128 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
138 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
143 ### Other Network Cards
146 ## Installation Status
147 Lab installation status is tracked by LF IT team in [FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
149 ## Server/Device Management and Naming
150 ### Server Management Requirements
151 Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
152 For management purposes, each server must have following two ports connected to the management network:
155 - IPMI - Intelligent Platform Management Interface.
156 - Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
157 - 1GE/10GE management port
158 - hostOS management port for general system management.
161 ### Server and Port Naming Convention
162 Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:
164 - testbedname: testbedN.
166 - traffic-generator: tN-tgW.
167 - system-under-testX: tN-sutX.
172 - N - testbed number.
173 - tgW - server acts as traffic-generator with W index.
174 - sutX - server acts as system-under-test with X index.
175 - Y - PCIe slot number denoting a NIC card number within the host.
176 - Y=2,4,9 - slots connected to NUMA node 0.
177 - Y=6,8,10 - slots connected to NUMA node 1.
178 - Z - port number on the NIC card.
181 ### Server Management - Addressing
182 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.
185 - Subnet: 10.30.50.0/24
186 - Gateway: 10.30.50.1
187 - Broadcast: 10.30.50.255
188 - DNS1: 199.204.44.24
189 - DNS2: 199.204.47.54
191 - Subnet: 10.30.51.0/24
192 - Gateway: 10.30.51.1
193 - Broadcast: 10.30.51.255
194 - DNS1: 199.204.44.24
195 - DNS2: 199.204.47.54
197 To access these hosts, an VPN connection is required.
199 ### LOM (IPMI) VLAN IP Addresses
202 ### Management VLAN IP Addresses
205 ## Testbeds Specification - Target Build
206 ### Server/Ports Naming, NIC Placement
208 Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
211 - testbedname: testbed11.
212 - hostname: s1-t11-sut1.
213 - IPMI IP: 10.30.50.47
214 - Host IP: 10.30.51.50
216 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
217 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
218 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
219 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
220 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
221 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
222 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
223 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
225 - testbedname: testbed12.
226 - hostname: s2-t12-sut1.
227 - IPMI IP: 10.30.50.48
228 - Host IP: 10.30.51.51
230 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
231 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
232 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
233 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
234 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
235 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
236 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
237 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
241 Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
244 - testbedname: testbed21.
245 - hostname: s3-t21-sut1.
246 - IPMI IP: 10.30.50.41
247 - Host IP: 10.30.51.44
249 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
250 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
251 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
252 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
253 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
254 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
255 - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
256 - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
258 - testbedname: testbed21.
259 - hostname: s4-t21-tg1.
260 - IPMI IP: 10.30.50.42
261 - Host IP: 10.30.51.45
263 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
264 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
265 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
266 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
267 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
268 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
269 - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
270 - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
272 - testbedname: testbed22.
273 - hostname: s5-t22-sut1.
274 - IPMI IP: 10.30.50.49
275 - Host IP: 10.30.51.52
277 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
278 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
279 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
280 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
281 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
282 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
283 - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
284 - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
286 - testbedname: testbed22.
287 - hostname: s6-t22-tg1.
288 - IPMI IP: 10.30.50.50
289 - Host IP: 10.30.51.53
291 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
292 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
293 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
294 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
295 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
296 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
297 - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
298 - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
300 - testbedname: testbed23.
301 - hostname: s7-t23-sut1.
302 - IPMI IP: 10.30.50.51
303 - Host IP: 10.30.51.54
305 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
306 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
307 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
308 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
309 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
310 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
311 - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
312 - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
314 - testbedname: testbed23.
315 - hostname: s8-t23-tg1.
316 - IPMI IP: 10.30.50.52
317 - Host IP: 10.30.51.55
319 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
320 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
321 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
322 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
323 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
324 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
325 - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
326 - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
328 - testbedname: testbed24.
329 - hostname: s9-t24-sut1.
330 - IPMI IP: 10.30.50.53
331 - Host IP: 10.30.51.56
333 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
334 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
335 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
336 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
337 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
338 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
339 - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
340 - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
342 - testbedname: testbed24.
343 - hostname: s10-t24-tg1.
344 - IPMI IP: 10.30.50.54
345 - Host IP: 10.30.51.57
347 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
348 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
349 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
350 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
351 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
352 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
353 - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
354 - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
358 Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
361 - testbedname: testbed31.
362 - hostname: s11-t31-sut1.
363 - IPMI IP: 10.30.50.43
364 - Host IP: 10.30.51.46
366 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
367 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
368 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
369 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
370 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
371 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
372 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
373 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
375 - testbedname: testbed31.
376 - hostname: s12-t31-sut2.
377 - IPMI IP: 10.30.50.44
378 - Host IP: 10.30.51.47
380 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
381 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
382 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
383 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
384 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
385 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
386 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
387 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
389 - testbedname: testbed31.
390 - hostname: s13-t31-tg1.
391 - IPMI IP: 10.30.50.45
392 - Host IP: 10.30.51.48
394 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
395 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
396 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
397 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
398 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
399 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
400 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
401 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
403 - testbedname: testbed32.
404 - hostname: s14-t32-sut1.
405 - IPMI IP: 10.30.50.55
406 - Host IP: 10.30.51.58
408 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
409 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
410 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
411 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
412 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
413 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
414 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
415 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
417 - testbedname: testbed32.
418 - hostname: s15-t32-sut2.
419 - IPMI IP: 10.30.50.56
420 - Host IP: 10.30.51.59
422 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
423 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
424 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
425 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
426 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
427 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
428 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
429 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
431 - testbedname: testbed32.
432 - hostname: s16-t32-tg1.
433 - IPMI IP: 10.30.50.57
434 - Host IP: 10.30.51.60
436 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
437 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
438 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
439 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
440 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
441 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
442 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
443 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
447 Note: Server19 (TG) is shared between testbed33 & testbed34
450 - testbedname: testbed33.
451 - hostname: s17-t33-sut1.
452 - IPMI IP: 10.30.50.36
453 - Host IP: 10.30.51.36
455 - s17-t33-sut1-ca/p1 - 10GE-port1 82599-2p10GE.
456 - s17-t33-sut1-ca/p2 - 10GE-port2 82599-2p10GE.
457 - s17-t33-sut1-c2/p1 - 25GE-port1 cx4-2p25GE.
458 - s17-t33-sut1-c2/p2 - 25GE-port2 cx4-2p25GE.
460 - testbedname: testbed33.
461 - hostname: s18-t33-sut2.
462 - IPMI IP: 10.30.50.37
463 - Host IP: 10.30.51.37
465 - s18-t33-sut2-ca/p1 - 10GE-port1 82599-2p10GE.
466 - s18-t33-sut2-ca/p2 - 10GE-port2 82599-2p10GE.
467 - s18-t33-sut2-c2/p1 - 25GE-port1 cx4-2p25GE.
468 - s18-t33-sut2-c2/p2 - 25GE-port2 cx4-2p25GE.
470 - testbedname: testbed33.
471 - hostname: s19-t33t34-tg1.
472 - IPMI IP: 10.30.50.46
473 - Host IP: 10.30.51.49
475 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
476 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
477 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
478 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
479 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
480 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
482 - testbedname: testbed34.
483 - hostname: s20-t34-sut1.
485 - Host IP: 10.30.51.41
487 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
488 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
490 - testbedname: testbed34.
491 - hostname: s21-t34-sut2.
493 - Host IP: 10.30.51.42
495 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
496 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
500 Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
503 - testbedname: testbed25.
504 - hostname: s25-t25-sut1.
505 - IPMI IP: 10.30.50.58
506 - Host IP: 10.30.51.61
508 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
509 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
510 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
511 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
513 - testbedname: testbed25.
514 - hostname: s26-t25-tg1.
515 - IPMI IP: 10.30.50.59
516 - Host IP: 10.30.51.62
518 - s26-t25-tg1-p1 - 10GE-port1.
519 - s26-t25-tg1-p2 - 10GE-port2.
520 - s26-t25-tg1-p3 - 10GE-port3.
521 - s26-t25-tg1-p4 - 10GE-port4.
525 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
528 - testbedname: testbed35.
529 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
530 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
531 - Host IP: 10.30.51.9
533 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
534 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
537 - testbedname: testbed35.
538 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
539 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
540 - Host IP: 10.30.51.10
542 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
543 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
546 - testbedname: testbed35.
547 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
548 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
549 - Host IP: 10.30.51.11
551 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
552 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
556 ### Physical Connectivity within Testbeds
558 Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification:
561 - ring1 10GE-ports x710-4p10GE:
562 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
563 - ring2 10GE-ports x710-4p10GE:
564 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
565 - ring3 10GE-ports x710-4p10GE:
566 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
567 - ring4 10GE-ports x710-4p10GE:
568 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
570 - ring1 10GE-ports x710-4p10GE:
571 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
572 - ring2 10GE-ports x710-4p10GE:
573 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
574 - ring3 10GE-ports x710-4p10GE:
575 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
576 - ring4 10GE-ports x710-4p10GE:
577 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
581 Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
584 - ring1 10GE-ports x710-4p10GE on SUT:
585 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
586 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
587 - ring2 10GE-ports x710-4p10GE on SUT:
588 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
589 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
590 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
591 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
592 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
593 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
594 - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
595 - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
596 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
597 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
598 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
600 - ring1 10GE-ports x710-4p10GE on SUT:
601 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
602 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
603 - ring2 10GE-ports x710-4p10GE on SUT:
604 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
605 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
606 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
607 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
608 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
609 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
610 - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
611 - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
612 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
613 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
614 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
616 - ring1 10GE-ports x710-4p10GE on SUT:
617 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
618 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
619 - ring2 10GE-ports x710-4p10GE on SUT:
620 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
621 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
622 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
623 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
624 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
625 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
626 - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
627 - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
628 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
629 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
630 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
632 - ring1 10GE-ports x710-4p10GE on SUT:
633 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
634 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
635 - ring2 10GE-ports x710-4p10GE on SUT:
636 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
637 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
638 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
639 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
640 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
641 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
642 - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
643 - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
644 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
645 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
646 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
650 Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification:
653 - ring1 10GE-ports x710-4p10GE on SUTs:
654 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
655 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
656 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
657 - ring2 10GE-ports x710-4p10GE on SUT:
658 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
659 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
660 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
661 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
662 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
663 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
664 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
665 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
666 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
667 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
668 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
669 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
670 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
671 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
673 - ring1 10GE-ports x710-4p10GE on SUTs:
674 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
675 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
676 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
677 - ring2 10GE-ports x710-4p10GE on SUT:
678 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
679 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
680 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
681 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
682 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
683 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
684 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
685 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
686 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
687 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
688 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
689 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
690 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
691 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
695 One 3-Node testbed is constructed by connecting 3 Arm servers using below specification:
698 - ring1 10GE-ports 82599-2p10GE on SUTs:
699 - t33t34-tg1-c2/p1 - t33-sut1-ca/p1.
700 - t33-sut1-ca/p2 - t33-sut2-ca/p1.
701 - t33-sut2-ca/p2 - t33t34-tg1-c2/p2.
702 - ring2 25GE-ports cx4-2p25GE on SUTs:
703 - t33t34-tg1-c4/p1 - t33-sut1-c2/p1.
704 - t33-sut1-c2/p2 - t33-sut2-c2/p1.
705 - t33-sut2-c2/p2 - t33t34-tg1-c4/p2.
707 - ring1 10GE-ports Marvell on SUTs:
708 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
709 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
710 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
714 One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification:
717 - link1 10GE-port x710-4p10GE on SUT:
718 - t25-tg1-p1 to t25-sut1-c2/p1.
719 - link2 10GE-port x710-4p10GE on SUT:
720 - t25-tg1-p2 to t25-sut1-c2/p2.
721 - link3 10GE-port x710-4p10GE on SUT:
722 - t25-tg1-p3 to t25-sut1-c2/p3.
723 - link4 10GE-port x710-4p10GE on SUT:
724 - t25-tg1-p4 to t25-sut1-c2/p4.
730 ## Server Specification
731 ### Hardware Configuration
732 The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations:
734 1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
735 - Quantity: TBD based on testbed allocation.
736 - Physical connectivity:
737 - IPMI and host management ports.
738 - NIC ports connected into 2-node and 3-node topologies.
739 - Main HW configuration:
740 - Chassis: SuperMicro SYS-7049GP-TRT.
741 - Motherboard: SuperMicro X11DPG-QT.
742 - Processors: 2* Intel Platinum 8180 2.3 GHz.
743 - RAM Memory: 16* 16GB DDR4-2666MHz.
744 - Disks: 2* 1.6TB 6G SATA SSD.
745 - NICs configuration:
746 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
747 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
748 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
749 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
750 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
751 - PCIe Slot6 86:00.xx: empty.
752 - PCIe Slot8 af:00.xx: empty.
753 - PCIe Slot10 d8:00.xx: empty.
754 2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
755 - Quantity: TBD based on testbed allocation.
756 - Physical connectivity:
757 - IPMI and host management ports.
758 - NIC ports connected into 2-node and 3-node topologies.
759 - Main HW configuration:
760 - Chassis: SuperMicro SYS-7049GP-TRT.
761 - Motherboard: SuperMicro X11DPG-QT.
762 - Processors: 2* Intel Platinum 8180 2.3 GHz.
763 - RAM Memory: 16* 16GB DDR4-2666MHz.
764 - Disks: 2* 1.6TB 6G SATA SSD.
765 - NICs configuration:
766 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
767 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
768 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
769 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
770 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
771 - PCIe Slot6 86:00.xx: empty.
772 - PCIe Slot8 af:00.xx: empty.
773 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
774 3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
776 - Physical connectivity:
777 - IPMI(?) and host management ports.
778 - NIC ports connected into 3-node topology.
779 - Main HW configuration:
780 - Chassis: Huawei TaiShan 2280.
781 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
782 - RAM Memory: 8* 16GB DDR4-2400MT/s
783 - Disks: 1* 4TB SATA HDD
784 - NICs configuration:
785 - PCIe Slot2 e9:00.xx: connectx4-2p25GE Mellanox.
786 - PCIe Slota 11:00.xx: 82599-2p10GE Intel.
787 4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
789 - Physical connectivity:
790 - Host management ports.
791 - NIC ports connected into 2-node and 3-node topologies.
792 - Main HW configuration:
793 - Chassis: MACCHIATObin.
794 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
795 - RAM Memory: 1* 16GB DDR4
796 - Disks: 1* 128GB(?) SATA SDD
797 - NICs configuration:
798 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
799 5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
800 - Quantity: TBD based on testbed allocation.
801 - Physical connectivity:
802 - Management: serial Port (usb) for console
803 - NIC ports connected into 2-node.
804 - Main HW configuration:
805 - Chassis: Netgate XG-2758-1u
806 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
807 - RAM Memory: 16GB ECC
809 - NICs configuration:
810 - 2x 10Gb Intel 82599ES
812 6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
814 - Physical connectivity:
815 - IPMI and host management ports.
816 - NIC ports connected into 2-node and 3-node topologies.
817 - Main HW configuration:
818 - Chassis: SuperMicro SYS-7049GP-TRT.
819 - Motherboard: SuperMicro X11DPG-QT.
820 - Processors: 2* Intel Platinum 8180 2.3 GHz.
821 - RAM Memory: 16* 16GB DDR4-2666MHz.
822 - Disks: 2* 1.6TB 6G SATA SSD.
823 - NICs configuration:
824 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
825 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
826 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
827 - PCIe Slot9 5e:00.xx: empty.
828 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
829 - PCIe Slot6 86:00.xx: empty.
830 - PCIe Slot8 af:00.xx: empty.
831 - PCIe Slot10 d8:00.xx: empty.
832 7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests.
834 - Physical connectivity:
835 - Host management interface: 10/100/1000-BaseT.
836 - 8-port 10GE SFP+ integrated NIC.
837 - Main HW configuration:
838 - Chassis: PS10GE4NG.
839 - Motherboard: SuperMicro X11DPG-QT.
840 - Processors: Quad-Core, Intel Processor.
841 - HW accelerators: FPGA offload.
843 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
844 - Physical Interfaces: 4 * 10GE SFP+.
845 - Operating System: Native IxOS.
846 - Interface configuration:
851 8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
853 - Physical connectivity:
854 - IPMI and host management ports.
856 - Main HW configuration:
857 - Chassis: SuperMicro SYS-7049GP-TRT.
858 - Motherboard: SuperMicro X11DPG-QT.
859 - Processors: 2* Intel Platinum 8180 2.3 GHz.
860 - RAM Memory: 16* 16GB DDR4-2666MHz.
861 - Disks: 2* 1.6TB 6G SATA SSD.
862 - NICs configuration:
863 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
864 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
865 - PCIe Slot4 3b:00.xx: empty.
866 - PCIe Slot9 5e:00.xx: empty.
867 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
868 - PCIe Slot6 86:00.xx: empty.
869 - PCIe Slot8 af:00.xx: empty.
870 - PCIe Slot10 d8:00.xx: empty.
871 9. Type-9: Purpose - (Cavium ThunderX2 Processor) SUT for VPP_Device functional tests.
873 - Physical connectivity:
874 - IPMI and host management ports.
875 - NIC ports connected into 1-node topologies.
876 - Main HW configuration:
877 - Chassis: Gigabyte R181-T90 1U
878 - Motheboard: MT91-FS1
879 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
880 - RAM Memory: 4* 32GB RDIMM
881 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
882 - NICs configuration:
883 - PCIe Slotx <TBD>: XL710-QDA2.
884 - PCIe Sloty <TBD>: XL710-QDA2.
885 - PCIe Slotz <TBD>: XL710-QDA2.
886 10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
888 - Physical connectivity:
889 - IPMI and host management ports.
891 - Main HW configuration:
892 - Chassis: SuperMicro SYS-E300-9A
893 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
894 - RAM Memory: 32GB ECC
896 - NICs configuration:
897 - 2x 10Gb Intel x553 fiber ports
898 - 2x 10Gb Intel x553 copper ports
899 - 4x 1GB Intel I350 ports
902 ### Xeon Skx Server BIOS Configuration
905 | Quiet Boot [Enabled] |Boot option |
907 | Option ROM Messages [Force BIOS] | |
908 | Bootup NumLock State [On] | |
909 | Wait For "F1" If Error [Enabled] | |
910 | INT19 Trap Response [Immediate] | |
911 | Re-try Boot [Disabled] | |
912 | Install Windows 7 USB support [Disabled] | |
913 | Port 61h Bit-4 Emulation [Disabled] | |
915 | Power Configuration | |
916 | Watch Dog Function [Disabled] | |
917 | Restore on AC Power Loss [Last State] | |
918 | Power Button Function [Instant Off] | |
919 | Throttle on Power Fail [Disabled] | |
922 #### CPU Configuration
924 | Processor Configuration |Enables Hyper Threading |
925 | -------------------------------------------------- |(Software Method to |
926 | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical |
927 | Processor Socket CPU1 | CPU2 |Processor threads. |
928 | Processor ID 00050654* | 000506... | |
929 | Processor Frequency 2.500GHz | 2.500GHz | |
930 | Processor Max Ratio 19H | 19H | |
931 | Processor Min Ratio 0AH | 0AH | |
932 | Microcode Revision 02000030 | |
933 | L1 Cache RAM 64KB | 64KB | |
934 | L2 Cache RAM 1024KB | 1024KB | |
935 | L3 Cache RAM 39424KB | 39424KB | |
936 | Processor 0 Version | |
937 | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
938 | Processor 1 Version | |
939 | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
941 | Hyper-Threading [ALL] [Enable] | |
942 | Core Disable Bitmap(Hex) 0 | |
943 | Execute Disable Bit [Enable] | |
944 | Intel Virtualization Technology [Enable] | |
945 | PPIN Control [Unlock/Enable] | |
946 | Hardware Prefetcher [Enable] | |
947 | Adjacent Cache Prefetch [Enable] | |
948 | DCU Streamer Prefetcher [Enable] | |
949 | DCU IP Prefetcher [Enable] | |
950 | LLC Prefetch [Disable] | |
951 | Extended APIC [Disable] | |
952 | AES-NI [Enable] | |
953 |> Advanced Power Management Configuration | |
956 ##### Advanced Power Management Configuration
958 | Advanced Power Management Configuration |Switch CPU Power Management |
959 | -------------------------------------------------- |profile |
960 | Power Technology [Custom] | |
961 | Power Performance Tuning [BIOS Controls EPB] | |
962 | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
963 |> CPU P State Control | |
964 |> Hardware PM State Control | |
965 |> CPU C State Control | |
966 |> Package C State Control | |
967 |> CPU T State Control | |
970 ###### CPU P State Control
972 | CPU P State Control |Enable/Disable EIST |
974 | SpeedStep (Pstates) [Disable] | |
975 | EIST PSD Function [HW_ALL] | |
978 ###### Hardware PM State Control
980 | Hardware PM State Control |Disable: Hardware chooses a |
981 | |P-state based on OS Request |
982 | Hardware P-States [Disable] |(Legacy P-States) |
983 | |Native Mode:Hardware |
984 | |chooses a P-state based on |
986 | |Out of Band Mode:Hardware |
987 | |autonomously chooses a |
988 | |P-state (no OS guidance) |
991 ###### CPU C State Control
993 | CPU C State Control |Autonomous Core C-State |
995 | Autonomous Core C-State [Disable] | |
996 | CPU C6 report [Disable] | |
997 | Enhanced Halt State (C1E) [Disable] | |
1000 ###### Package C State Control
1002 | Package C State Control |Package C State limit |
1004 | Package C State [C0/C1 state] | |
1007 ###### CPU T State Control
1009 | CPU T State Control |Enable/Disable Software |
1010 | |Controlled T-States |
1011 | Software Controlled T-States [Disable] | |
1014 ##### Chipset Configuration
1016 | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
1017 | system to malfunction. | |
1024 |> UPI Configuration |Displays and provides |
1025 |> Memory Configuration |option to change the UPI |
1026 |> IIO Configuration |Settings |
1029 ###### UPI Configuration
1031 | UPI Configuration |Choose Topology Precedence |
1032 | -------------------------------------------------- |to degrade features if |
1033 | Number of CPU 2 |system options are in |
1034 | Number of Active UPI Link 3 |conflict or choose Feature |
1035 | Current UPI Link Speed Fast |Precedence to degrade |
1036 | Current UPI Link Frequency 10.4 GT/s |topology if system options |
1037 | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. |
1038 | UPI Global MMIO High Base / Limit 0000000000000000 / ... | |
1039 | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | |
1040 | Degrade Precedence [Topology Precedence] | |
1041 | Link L0p Enable [Disable] | |
1042 | Link L1 Enable [Disable] | |
1043 | IO Directory Cache (IODC) [Auto] | |
1045 | XPT Prefetch [Disable] | |
1046 | KTI Prefetch [Enable] | |
1047 | Local/Remote Threshold [Auto] | |
1048 | Stale AtoS [Disable] | |
1049 | LLC dead line alloc [Enable] | |
1050 | Isoc Mode [Auto] | |
1053 ###### Memory Configuration
1055 | |POR - Enforces Plan Of |
1056 | -------------------------------------------------- |Record restrictions for |
1057 | Integrated Memory Controller (iMC) |DDR4 frequency and voltage |
1058 | -------------------------------------------------- |programming. Disable - |
1059 | |Disables this feature. |
1060 | Enforce POR [Disable] | |
1061 | Memory Frequency [2666] | |
1062 | Data Scrambling for NVMDIMM [Auto] | |
1063 | Data Scrambling for DDR4 [Auto] | |
1064 | tCCD_L Relaxation [Auto] | |
1065 | Memory tRWSR Relaxation [Enable] | |
1066 | 2X REFRESH [Auto] | |
1067 | Page Policy [Auto] | |
1068 | IMC Interleaving [2-way Interleave] | |
1069 |> Memory Topology | |
1070 |> Memory RAS Configuration | |
1073 ###### IIO Configuration
1075 | IIO Configuration |Expose IIO DFX devices and |
1076 | -------------------------------------------------- |other CPU devices like PMON |
1078 | EV DFX Features [Disable] | |
1079 |> CPU1 Configuration | |
1080 |> CPU2 Configuration | |
1081 |> IOAT Configuration | |
1082 |> Intel. VT for Directed I/O (VT-d) | |
1083 |> Intel. VMD technology | |
1085 | IIO-PCIE Express Global Options | |
1086 | ======================================== | |
1087 | PCI-E Completion Timeout Disable [No] | |
1090 ###### CPU1 Configuration
1092 | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
1093 | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
1094 | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
1095 |> CPU1 SLOT2 PCI-E 3.0 X16 | |
1096 |> CPU1 SLOT4 PCI-E 3.0 X16 | |
1097 |> CPU1 SLOT9 PCI-E 3.0 X16 | |
1100 ###### CPU2 Configuration
1102 | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
1103 | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
1104 | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
1105 |> CPU2 SLOT6 PCI-E 3.0 X16 | |
1106 |> CPU2 SLOT8 PCI-E 3.0 X16 | |
1107 |> CPU2 SLOT10 PCI-E 3.0 X16 | |
1112 | |Enables Legacy USB support. |
1113 | USB Module Version 17 |AUTO option disables legacy |
1114 | |support if no USB devices |
1115 | USB Devices: |are connected. DISABLE |
1116 | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
1117 | |devices available only for |
1118 | Legacy USB Support [Enabled] |EFI applications. |
1119 | XHCI Hand-off [Disabled] | |
1120 | Port 60/64 Emulation [Enabled] | |
1121 | PCIe PLL SSC [Disable] | |
1122 | Real USB Wake Up [Enabled] | |
1123 | Front USB Wake Up [Enabled] | |
1126 | Azalia PME Enable [Disabled] | |
1129 #### PCIe/PCI/PnP Configuration
1131 | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit |
1132 | |capable Devices to be |
1133 | PCI Devices Common Settings: |Decoded in Above 4G Address |
1134 | Above 4G Decoding [Enabled] |Space (Only if System |
1135 | SR-IOV Support [Enabled] |Supports 64 bit PCI |
1136 | MMIO High Base [56T] |Decoding). |
1137 | MMIO High Granularity Size [256G] | |
1138 | Maximum Read Request [Auto] | |
1139 | MMCFG Base [2G] | |
1140 | NVMe Firmware Source [Vendor Defined Fi...] | |
1141 | VGA Priority [Onboard] | |
1142 | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | |
1143 | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | |
1144 | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | |
1145 | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | |
1146 | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | |
1147 | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | |
1148 | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | |
1149 | M.2 CONNECTOR OPROM [Legacy] | |
1150 | Onboard LAN1 Option ROM [Legacy] | |
1151 | Onboard LAN2 Option ROM [Disabled] | |
1152 | Onboard Video Option ROM [Legacy] | |
1153 |> Network Stack Configuration | |
1158 | ACPI Settings |Enable or Disable Non |
1159 | |uniform Memory Access |
1160 | NUMA [Enabled] |(NUMA). |
1161 | WHEA Support [Enabled] | |
1162 | High Precision Event Timer [Enabled] | |
1163 | ACPI Sleep State [S3 (Suspend to RAM)] | |
1169 Getting SMBIOS data from sysfs.
1170 SMBIOS 3.1.1 present.
1171 Table at 0x000E89C0.
1173 Handle 0x0000, DMI type 0, 26 bytes
1175 Vendor: American Megatrends Inc.
1177 Release Date: 11/29/2017
1184 BIOS shadowing is allowed
1185 Boot from CD is supported
1186 Selectable boot is supported
1187 BIOS ROM is socketed
1189 5.25"/1.2 MB floppy services are supported (int 13h)
1190 3.5"/720 kB floppy services are supported (int 13h)
1191 3.5"/2.88 MB floppy services are supported (int 13h)
1192 Print screen service is supported (int 5h)
1193 Serial services are supported (int 14h)
1194 Printer services are supported (int 17h)
1196 USB legacy is supported
1197 BIOS boot specification is supported
1198 Targeted content distribution is supported
1202 Handle 0x0001, DMI type 1, 27 bytes
1204 Manufacturer: Supermicro
1205 Product Name: SYS-7049GP-TRT
1207 Serial Number: S291427X8332242
1208 UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
1209 Wake-up Type: Power Switch
1210 SKU Number: To be filled by O.E.M.
1211 Family: To be filled by O.E.M.
1213 Handle 0x0002, DMI type 2, 15 bytes
1214 Base Board Information
1215 Manufacturer: Supermicro
1216 Product Name: X11DPG-QT
1218 Serial Number: VM183S014930
1219 Asset Tag: To be filled by O.E.M.
1221 Board is a hosting board
1222 Board is replaceable
1223 Location In Chassis: To be filled by O.E.M.
1224 Chassis Handle: 0x0003
1226 Contained Object Handles: 0
1228 Handle 0x0003, DMI type 3, 22 bytes
1230 Manufacturer: Supermicro
1234 Serial Number: C7470KH06A20167
1235 Asset Tag: To be filled by O.E.M.
1237 Power Supply State: Safe
1239 Security Status: None
1240 OEM Information: 0x00000000
1242 Handle 0x0050, DMI type 4, 48 bytes
1243 Processor Information
1244 Socket Designation: CPU1
1245 Type: Central Processor
1247 Manufacturer: Intel(R) Corporation
1248 ID: 54 06 05 00 FF FB EB BF
1249 Signature: Type 0, Family 6, Model 85, Stepping 4
1251 FPU (Floating-point unit on-chip)
1252 VME (Virtual mode extension)
1253 DE (Debugging extension)
1254 PSE (Page size extension)
1255 TSC (Time stamp counter)
1256 MSR (Model specific registers)
1257 PAE (Physical address extension)
1258 MCE (Machine check exception)
1259 CX8 (CMPXCHG8 instruction supported)
1260 APIC (On-chip APIC hardware supported)
1261 SEP (Fast system call)
1262 MTRR (Memory type range registers)
1263 PGE (Page global enable)
1264 MCA (Machine check architecture)
1265 CMOV (Conditional move instruction supported)
1266 PAT (Page attribute table)
1267 PSE-36 (36-bit page size extension)
1268 CLFSH (CLFLUSH instruction supported)
1270 ACPI (ACPI supported)
1271 MMX (MMX technology supported)
1272 FXSR (FXSAVE and FXSTOR instructions supported)
1273 SSE (Streaming SIMD extensions)
1274 SSE2 (Streaming SIMD extensions 2)
1276 HTT (Multi-threading)
1277 TM (Thermal monitor supported)
1278 PBE (Pending break enabled)
1279 Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
1281 External Clock: 100 MHz
1283 Current Speed: 2500 MHz
1284 Status: Populated, Enabled
1286 L1 Cache Handle: 0x004D
1287 L2 Cache Handle: 0x004E
1288 L3 Cache Handle: 0x004F
1289 Serial Number: Not Specified
1291 Part Number: Not Specified
1300 Enhanced Virtualization
1301 Power/Performance Control
1304 Handle 0x0054, DMI type 4, 48 bytes
1305 Processor Information
1306 Socket Designation: CPU2
1307 Type: Central Processor
1309 Manufacturer: Intel(R) Corporation
1310 ID: 54 06 05 00 FF FB EB BF
1311 Signature: Type 0, Family 6, Model 85, Stepping 4
1313 FPU (Floating-point unit on-chip)
1314 VME (Virtual mode extension)
1315 DE (Debugging extension)
1316 PSE (Page size extension)
1317 TSC (Time stamp counter)
1318 MSR (Model specific registers)
1319 PAE (Physical address extension)
1320 MCE (Machine check exception)
1321 CX8 (CMPXCHG8 instruction supported)
1322 APIC (On-chip APIC hardware supported)
1323 SEP (Fast system call)
1324 MTRR (Memory type range registers)
1325 PGE (Page global enable)
1326 MCA (Machine check architecture)
1327 CMOV (Conditional move instruction supported)
1328 PAT (Page attribute table)
1329 PSE-36 (36-bit page size extension)
1330 CLFSH (CLFLUSH instruction supported)
1332 ACPI (ACPI supported)
1333 MMX (MMX technology supported)
1334 FXSR (FXSAVE and FXSTOR instructions supported)
1335 SSE (Streaming SIMD extensions)
1336 SSE2 (Streaming SIMD extensions 2)
1338 HTT (Multi-threading)
1339 TM (Thermal monitor supported)
1340 PBE (Pending break enabled)
1341 Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
1343 External Clock: 100 MHz
1345 Current Speed: 2500 MHz
1346 Status: Populated, Enabled
1348 L1 Cache Handle: 0x0051
1349 L2 Cache Handle: 0x0052
1350 L3 Cache Handle: 0x0053
1351 Serial Number: Not Specified
1353 Part Number: Not Specified
1362 Enhanced Virtualization
1363 Power/Performance Control
1366 ### Xeon Skx Server Firmware Inventory
1368 Host. IPMI IP. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e.
1369 s1-t11-sut1. 10.30.50.47. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1370 s2-t12-sut1. 10.30.50.48. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1371 s3-t21-sut1. 10.30.50.41. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1372 s4-t21-tg1. 10.30.50.42. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1373 s5-t22-sut1. 10.30.50.49. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1374 s6-t22-tg1. 10.30.50.50. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1375 s7-t23-sut1. 10.30.50.51. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1376 s8-t23-tg1. 10.30.50.52. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1377 s9-t24-sut1. 10.30.50.53. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1378 s10-t24-tg1. 10.30.50.54. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1379 s11-t31-sut1. 10.30.50.43. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1380 s12-t31-sut2. 10.30.50.44. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1381 s13-t31-tg1. 10.30.50.45. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1382 s14-t32-sut1. 10.30.50.55. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1383 s15-t32-sut2. 10.30.50.56. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1384 s16-t32-tg1. 10.30.50.57. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
1385 s19-t33t34-tg1. 10.30.50.46. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.