1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
16 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
19 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
20 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
21 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
22 1. [Server Management](#server-management)
23 1. [Requirements](#requirements)
24 1. [Addressing](#addressing)
25 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
26 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
27 1. [Server Specifications](#server-specifications)
28 1. [Server Types](#server-types)
29 1. [Naming Convention](#naming-convention)
30 1. [Testbeds Configuration](#testbeds-configuration)
31 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
32 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
33 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
34 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
35 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
36 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
37 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
38 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
39 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
40 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
41 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
42 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
43 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
44 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
45 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
46 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
47 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
48 1. [Per Testbed Wiring](#per-testbed-wiring)
49 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
50 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
51 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
52 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
53 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
54 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
55 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
56 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
57 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
58 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
59 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
60 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
61 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
62 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
63 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
64 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
65 1. [Inventory](#inventory)
66 1. [Appliances](#appliances)
67 1. [Arm Servers](#arm-servers)
68 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
69 1. [Network Interface Cards](#network-interface-cards)
70 1. [Pluggables and Cables](#pluggables-and-cables)
71 1. [Other Parts](#other-parts)
75 This note includes specification of the physical testbed infrastructure
76 hosted by LFN FD.io CSIT project.
83 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
84 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 0
85 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 0
86 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0
87 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0
88 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0 0
89 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0 0
90 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 0
91 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0
92 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0
93 10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 0
94 11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
95 12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0
96 13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0
97 14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0
98 15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0
99 16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0
100 17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0
101 18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0
102 19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2
103 Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2
106 ### 1-Node-Skylake Xeon Intel (1n-skx)
108 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
109 ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
112 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
114 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
115 ports connected back-to-back ([Server Types](#server-types)).
116 Used for FD.io VPP_Device functional driver tests.
118 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
120 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
121 NIC ports connected back-to-back ([Server Types](#server-types)).
123 Used for FD.io VPP_Device functional driver tests.
125 ### 2-Node-Skylake Xeon Intel (2n-skx)
127 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
128 (Server-Type-B2) connected in a 2-node circular topology
129 ([Server Types](#server-types)).
130 Used for FD.io performance tests.
132 ### 2-Node-Denverton Atom Intel (2n-dnv)
134 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
135 TG (Server-Type-B2) connected in a 2-node circular topology
136 ([Server Types](#server-types)).
137 Used for FD.io performance tests.
139 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
141 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
142 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
143 circular topology ([Server Types](#server-types)).
144 Used for FD.io TCP/IP and HTTP performance tests.
146 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
148 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
149 one TG (Server-Type-C3) connected in a 2-node circular topology
150 ([Server Types](#server-types)).
151 Used for FD.io performance tests.
153 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
155 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
156 one TG (Server-Type-D2) connected in a 2-node circular topology
157 ([Server Types](#server-types)).
158 Used for FD.io performance tests.
160 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
162 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
163 one TG (Server-Type-E31) connected in a 2-node circular topology
164 ([Server Types](#server-types)).
165 Used for FD.io performance tests.
167 ### 2-Node-Icelake Xeon Intel (2n-icx)
169 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
170 one TG (Server-Type-F2) connected in a 2-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
174 ### 3-Node-Haswell Xeon Intel (3n-hsw)
176 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
177 TG (Server-Type-A2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
181 ### 3-Node-Skylake Xeon Intel (3n-skx)
183 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
184 TG (Server-Type-B2) connected in a 3-node circular topology.
185 Used for FD.io performance tests.
187 ### 3-Node-Rangeley Atom Testbeds
189 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
190 TG (Server-Type-2) connected in a 3-node circular topology
191 ([Server Types](#server-types)).
192 Used for FD.io performance tests.
194 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
196 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
197 TG (Server-Type-E31) connected in a 3-node circular topology
198 ([Server Types](#server-types)).
199 Used for FD.io performance tests.
201 ### 3-Node-Altra Arm Ampere (3n-alt)
203 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
204 TG (Server-Type-F4) connected in a 3-node circular topology
205 ([Server Types](#server-types)).
206 Used for FD.io performance tests.
208 ### 3-Node-Icelake Xeon Intel (3n-icx)
210 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
211 TG (Server-Type-F3) connected in a 3-node circular topology
212 ([Server Types](#server-types)).
213 Used for FD.io performance tests.
215 ### 3-Node-SnowRidge Atom Intel (3n-snr)
217 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
218 TG (Server-Type-F4) connected in a 3-node circular topology
219 ([Server Types](#server-types)).
220 Used for FD.io performance tests.
227 For management purposes, each server must have following two ports
228 connected to the management network:
232 - IPMI - Intelligent Platform Management Interface.
233 - Required for access to embedded server management with WebUI, CLI,
234 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
235 - 1GE/10GE/40GE management port
236 - hostOS management port for general system management.
241 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
242 Management port, which are connected to two different VLANs.
246 - Subnet: 10.30.50.0/24
247 - Gateway: 10.30.50.1
248 - Broadcast: 10.30.50.255
249 - DNS1: 199.204.44.24
250 - DNS2: 199.204.47.54
252 - Subnet: 10.30.51.0/24
253 - Gateway: 10.30.51.1
254 - Broadcast: 10.30.51.255
255 - DNS1: 199.204.44.24
256 - DNS2: 199.204.47.54
259 To access these hosts, VPN connection is required.
261 ### LOM (IPMI) VLAN IP Addresses
264 ------------ | -------
267 10.30.50.2 | LF Reserved
268 10.30.50.3 | LF Reserved
269 10.30.50.4 | LF Reserved
270 10.30.50.5 | LF Reserved
271 10.30.50.6 | LF Reserved
272 10.30.50.7 | LF Reserved
273 10.30.50.8 | LF Reserved
274 10.30.50.9 | LF Reserved
275 10.30.50.10 | LF Reserved
276 10.30.50.11 | LF Reserved
277 10.30.50.12 | LF Reserved
278 10.30.50.13 | LF Reserved
279 10.30.50.14 | LF Reserved
280 10.30.50.15 | LF Reserved
281 10.30.50.16 | s16-nomad
282 10.30.50.17 | s17-nomad
283 10.30.50.18 | s18-nomad
284 10.30.50.19 | s19-nomad
285 10.30.50.20 | s20-nomad
286 10.30.50.21 | s21-nomad
287 10.30.50.22 | s22-nomad
288 10.30.50.23 | s23-nomad
289 10.30.50.24 | s24-nomad
290 10.30.50.25 | s25-nomad
291 10.30.50.26 | s26-nomad
292 10.30.50.36 | s17-t33-sut1
293 10.30.50.37 | s18-t33-sut2
294 10.30.50.38 | fdio-marvell-dev
295 10.30.50.41 | s3-t21-sut1
296 10.30.50.42 | s4-t21-tg1
297 10.30.50.43 | s11-t31-sut1
298 10.30.50.44 | s12-t31-sut2
299 10.30.50.45 | s13-t31-tg1
300 10.30.50.46 | s19-t33t211-tg1
301 10.30.50.47 | s1-t11-sut1
302 10.30.50.48 | s2-t12-sut1
303 10.30.50.49 | s5-t22-sut1
304 10.30.50.50 | s6-t22-tg1
305 10.30.50.51 | s7-t23-sut1
306 10.30.50.52 | s8-t23-tg1
307 10.30.50.53 | s9-t24-sut1
308 10.30.50.54 | s10-t24-tg1
309 10.30.50.55 | s14-t32-sut1
310 10.30.50.56 | s15-t32-sut2
311 10.30.50.57 | s16-t32-tg1
312 10.30.50.58 | s25-t25-sut1
313 10.30.50.59 | s26-t25-tg1
314 10.30.50.69 | s27-t211-sut1
315 10.30.50.70 | s55-t13-sut1
316 10.30.50.71 | s56-t14-sut1
317 10.30.50.72 | s62-t34-sut1
318 10.30.50.73 | s63-t34-sut2
319 10.30.50.74 | s64-t34-tg1
320 10.30.50.75 | s65-t37-sut1
321 10.30.50.76 | s66-t37-sut2
322 10.30.50.77 | s67-t37-tg1
323 10.30.50.78 | s78-t38-sut1
324 10.30.50.79 | s79-t38-sut2
325 10.30.50.80 | s80-t38-tg1
326 10.30.50.81 | s71-t212-sut1
327 10.30.50.82 | s72-t212-tg1
328 10.30.50.83 | s83-t213-sut1
329 10.30.50.84 | s84-t213-tg1
330 10.30.50.85 | s85-t214-sut1
331 10.30.50.86 | s86-t214-tg1
332 10.30.50.87 | s87-t215-sut1
333 10.30.50.88 | s88-t215-tg1
334 10.30.50.89 | s89-t39t310-tg1
335 10.30.50.90 | s90-t311t312-tg1
336 10.30.50.91 | s91-nomad
337 10.30.50.92 | s92-nomad
338 10.30.50.93 | s93-t39-sut1
339 10.30.50.94 | s94-t39-sut2
340 10.30.50.255 | Broadcast
343 10.30.55.10 | s28-t26t35-tg1
344 10.30.55.11 | s29-t26-sut1
345 10.30.55.12 | s30-t35-sut1
346 10.30.55.13 | s31-t35-sut2
347 10.30.55.18 | s33-t27-sut1
348 10.30.55.19 | s34-t27-tg1
349 10.30.55.20 | s35-t28-sut1
350 10.30.55.21 | s36-t28-tg1
351 10.30.55.22 | s37-t29-sut1
352 10.30.55.23 | s38-t29-tg1
353 10.30.55.24 | s60-t210-sut1
354 10.30.55.25 | s61-t210-tg1
355 10.30.55.255 | Broadcast
357 ### Management VLAN IP Addresses
360 -------------| -------
363 10.30.51.2 | LF Reserved
364 10.30.51.3 | LF Reserved
365 10.30.51.4 | LF Reserved
366 10.30.51.5 | LF Reserved
367 10.30.51.6 | LF Reserved
368 10.30.51.7 | LF Reserved
369 10.30.51.8 | LF Reserved
370 10.30.51.15 | LF Reserved
371 10.30.51.16 | s16-nomad
372 10.30.51.17 | s17-nomad
373 10.30.51.18 | s18-nomad
374 10.30.51.19 | s19-nomad
375 10.30.51.20 | s20-nomad
376 10.30.51.21 | s21-nomad
377 10.30.51.22 | s22-nomad
378 10.30.51.23 | s23-nomad
379 10.30.51.24 | s24-nomad
380 10.30.51.25 | s25-nomad
381 10.30.51.26 | s26-nomad
382 10.30.51.36 | s17-t33-sut1
383 10.30.51.37 | s18-t33-sut2
384 10.30.51.38 | fdio-marvell-dev
385 10.30.51.44 | s3-t21-sut1
386 10.30.51.45 | s4-t21-tg1
387 10.30.51.46 | s11-t31-sut1
388 10.30.51.47 | s12-t31-sut2
389 10.30.51.48 | s13-t31-tg1
390 10.30.51.49 | s19-t33t211-tg1
391 10.30.51.50 | s1-t11-sut1
392 10.30.51.51 | s2-t12-sut1
393 10.30.51.52 | s5-t22-sut1
394 10.30.51.53 | s6-t22-tg1
395 10.30.51.54 | s7-t23-sut1
396 10.30.51.55 | s8-t23-tg1
397 10.30.51.56 | s9-t24-sut1
398 10.30.51.57 | s10-t24-tg1
399 10.30.51.58 | s14-t32-sut1
400 10.30.51.59 | s15-t32-sut2
401 10.30.51.60 | s16-t32-tg1
402 10.30.51.61 | s25-t25-sut1
403 10.30.51.62 | s26-t25-tg1
404 10.30.51.69 | s27-t211-sut1
405 10.30.51.70 | s55-t13-sut1
406 10.30.51.71 | s56-t14-sut1
407 10.30.51.72 | s62-t34-sut1
408 10.30.51.73 | s63-t34-sut2
409 10.30.51.74 | s64-t34-tg1
410 10.30.51.75 | s65-t37-sut1
411 10.30.51.76 | s66-t37-sut2
412 10.30.51.77 | s67-t37-tg1
413 10.30.51.78 | s78-t38-sut1
414 10.30.51.79 | s79-t38-sut2
415 10.30.51.80 | s80-t38-tg1
416 10.30.51.81 | s71-t212-sut1
417 10.30.51.82 | s72-t212-tg1
418 10.30.51.83 | s83-t213-sut1
419 10.30.51.84 | s84-t213-tg1
420 10.30.51.85 | s85-t214-sut1
421 10.30.51.86 | s86-t214-tg1
422 10.30.51.87 | s87-t215-sut1
423 10.30.51.88 | s88-t215-tg1
424 10.30.51.89 | s89-t39t310-tg1
425 10.30.51.90 | s90-t311t312-tg1
426 10.30.51.91 | s91-nomad
427 10.30.51.92 | s92-nomad
428 10.30.51.93 | s93-t39-sut1
429 10.30.51.94 | s94-t39-sut2
430 10.30.51.255 | Broadcast
433 10.32.8.10 | s28-t26t35-tg1
434 10.32.8.11 | s29-t26-sut1
435 10.32.8.12 | s30-t35-sut1
436 10.32.8.13 | s31-t35-sut2
437 10.32.8.18 | s33-t27-sut1
438 10.32.8.19 | s34-t27-tg1
439 10.32.8.20 | s35-t28-sut1
440 10.32.8.21 | s36-t28-tg1
441 10.32.8.22 | s37-t29-sut1
442 10.32.8.23 | s38-t29-tg1
443 10.32.8.24 | s60-t210-sut1
444 10.32.8.25 | s61-t210-tg1
445 10.32.8.255 | Broadcast
447 ## Server Specifications
451 FD.io CSIT lab contains following server types:
453 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
454 - Quantity: 6 servers.
455 - Physical connectivity:
456 - CIMC and host management ports.
457 - NIC ports connected in 3-node topologies.
458 - Main HW configuration:
459 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
460 - Processors: 2* E5-2699v3 2.3 GHz.
461 - RAM Memory: 16* 32GB DDR4-2133MHz.
462 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
463 - NICs configuration:
464 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
468 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
472 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
473 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
474 - Quantity: 3 servers.
475 - Physical connectivity:
476 - CIMC and host management ports.
477 - NIC ports connected in 3-node topologies.
478 - Main HW configuration:
479 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
480 - Processors: 2* E5-2699v3 2.3 GHz.
481 - RAM Memory: 16* 32GB DDR4-2133MHz.
482 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
483 - NICs configuration:
484 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
488 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
493 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
494 - Quantity: 3 servers.
495 - Physical connectivity:
496 - CIMC and host management ports.
497 - no NIC ports, standalone setup.
498 - Main HW configuration:
499 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
500 - Processors: 2* E5-2699v3 2.3 GHz.
501 - RAM Memory: 16* 32GB DDR4-2133MHz.
502 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
503 - NICs configuration:
504 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
506 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
509 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
511 - Physical connectivity:
512 - IPMI and host management ports.
513 - NIC ports connected into 2-node and 3-node topologies.
514 - Main HW configuration:
515 - Chassis: SuperMicro SYS-7049GP-TRT.
516 - Motherboard: SuperMicro X11DPG-QT.
517 - Processors: 2* Intel Platinum 8180 2.5 GHz.
518 - RAM Memory: 16* 16GB DDR4-2666MHz.
519 - Disks: 2* 1.6TB 6G SATA SSD.
520 - NICs configuration:
521 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
522 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
523 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
524 - PCIe Slot9 5e:00.xx: empty.
525 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
526 - PCIe Slot6 86:00.xx: empty.
527 - PCIe Slot8 af:00.xx: empty.
528 - PCIe Slot10 d8:00.xx: empty.
529 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
531 - Physical connectivity:
532 - IPMI and host management ports.
533 - NIC ports connected into 2-node and 3-node topologies.
534 - Main HW configuration:
535 - Chassis: SuperMicro SYS-7049GP-TRT.
536 - Motherboard: SuperMicro X11DPG-QT.
537 - Processors: 2* Intel Platinum 8180 2.5 GHz.
538 - RAM Memory: 16* 16GB DDR4-2666MHz.
539 - Disks: 2* 1.6TB 6G SATA SSD.
540 - NICs configuration:
541 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
542 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
543 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
544 - PCIe Slot9 5e:00.xx: empty.
545 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
546 - PCIe Slot6 86:00.xx: empty.
547 - PCIe Slot8 af:00.xx: empty.
548 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
549 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
550 - Quantity: TBD based on testbed allocation.
551 - Physical connectivity:
552 - Management: serial Port (usb) for console
553 - NIC ports connected into 2-node.
554 - Main HW configuration:
555 - Chassis: Netgate XG-2758-1u
556 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
557 - RAM Memory: 16GB ECC
559 - NICs configuration:
560 - 2x 10Gb Intel 82599ES
562 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
564 - Physical connectivity:
565 - IPMI and host management ports.
566 - NIC ports connected into 1-node topologies.
567 - Main HW configuration:
568 - Chassis: SuperMicro SYS-7049GP-TRT.
569 - Motherboard: SuperMicro X11DPG-QT.
570 - Processors: 2* Intel Platinum 8180 2.5 GHz.
571 - RAM Memory: 16* 16GB DDR4-2666MHz.
572 - Disks: 2* 1.6TB 6G SATA SSD.
573 - NICs configuration:
574 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
575 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
576 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
577 - PCIe Slot9 5e:00.xx: empty.
578 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
579 - PCIe Slot6 86:00.xx: empty.
580 - PCIe Slot8 af:00.xx: empty.
581 - PCIe Slot10 d8:00.xx: empty.
582 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
584 - Physical connectivity:
585 - Host management interface: 10/100/1000-BaseT.
586 - 8-port 10GE SFP+ integrated NIC.
587 - Main HW configuration:
588 - Chassis: PS10GE4NG.
589 - Motherboard: SuperMicro X11DPG-QT.
590 - Processors: Quad-Core, Intel Processor.
591 - HW accelerators: FPGA offload.
593 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
594 - Physical Interfaces: 4 * 10GE SFP+.
595 - Operating System: Native IxOS.
596 - Interface configuration:
601 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
603 - Physical connectivity:
604 - IPMI and host management ports.
606 - Main HW configuration:
607 - Chassis: SuperMicro SYS-7049GP-TRT.
608 - Motherboard: SuperMicro X11DPG-QT.
609 - Processors: 2* Intel Platinum 8180 2.5 GHz.
610 - RAM Memory: 16* 16GB DDR4-2666MHz.
611 - Disks: 2* 1.6TB 6G SATA SSD.
612 - NICs configuration:
613 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
614 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
615 - PCIe Slot4 3b:00.xx: empty.
616 - PCIe Slot9 5e:00.xx: empty.
617 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
618 - PCIe Slot6 86:00.xx: empty.
619 - PCIe Slot8 af:00.xx: empty.
620 - PCIe Slot10 d8:00.xx: empty.
621 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
623 - Physical connectivity:
624 - IPMI and host management ports.
626 - Main HW configuration:
627 - Chassis: SuperMicro SYS-E300-9A
628 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
629 - RAM Memory: 32GB ECC
631 - NICs configuration:
632 - 2x 10Gb Intel x553 fiber ports
633 - 2x 10Gb Intel x553 copper ports
634 - 4x 1GB Intel I350 ports
635 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
637 - Physical connectivity:
638 - IPMI and host management ports.
639 - NIC ports connected into 1-node testbed topologies.
640 - Main HW configuration:
641 - Chassis: SuperMicro SYS-7049GP-TRT.
642 - Motherboard: SuperMicro X11DPG-QT.
643 - Processors: 2* Intel Platinum 8280 2.7 GHz.
644 - RAM Memory: 12* 16GB DDR4-2933.
645 - Disks: 2* 1.92TB SATA SSD.
646 - NICs configuration:
647 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
648 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
649 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
650 - PCIe Slot9 5e:00.xx: empty.
651 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
652 - PCIe Slot6 86:00.xx: empty.
653 - PCIe Slot8 af:00.xx: empty.
654 - PCIe Slot10 d8:00.xx: empty.
655 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
657 - Physical connectivity:
658 - IPMI and host management ports.
659 - NIC ports connected into 2-node testbed topologies.
660 - Main HW configuration:
661 - Chassis: SuperMicro SYS-7049GP-TRT.
662 - Motherboard: SuperMicro X11DPG-QT.
663 - Processors: 2* Intel Gold 6252N 2.3 GHz.
664 - RAM Memory: 12* 16GB DDR4-2933.
665 - Disks: 2* 1.92TB SATA SSD.
666 - NICs configuration:
667 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
668 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
669 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
670 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
671 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
672 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
673 - PCIe Slot8 af:00.xx: empty.
674 - PCIe Slot10 d8:00.xx: empty.
675 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
677 - Physical connectivity:
678 - IPMI and host management ports.
679 - NIC ports connected into 2-node testbed topologies.
680 - Main HW configuration:
681 - Chassis: SuperMicro SYS-7049GP-TRT.
682 - Motherboard: SuperMicro X11DPG-QT.
683 - Processors: 2* Intel Platinum 8280 2.7 GHz.
684 - RAM Memory: 12* 16GB DDR4-2933.
685 - Disks: 2* 1.92TB SATA SSD.
686 - NICs configuration:
687 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
688 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
689 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
690 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
691 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
692 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
693 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
694 - PCIe Slot10 d8:00.xx: empty.
695 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
697 - Physical connectivity:
698 - IPMI and host management ports.
699 - no NIC ports, standalone setup.
700 - Main HW configuration:
701 - Chassis: SuperMicro 1029P-WTRT.
702 - Motherboard: SuperMicro X11DDW-NT.
703 - Processors: 2* Intel Platinum 8280 2.7 GHz.
704 - RAM Memory: 12* 16GB DDR4-2933.
705 - Disks: 4* 1.92TB SATA SSD.
706 - NICs configuration:
711 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
713 - Physical connectivity:
714 - IPMI and host management ports.
715 - NIC ports connected into 2-node testbed topologies.
716 - Main HW configuration:
717 - Chassis: SuperMicro AS-1114S-WTRT
718 - Processors: 1* AMD EPYC 7532 2.4 GHz.
719 - RAM Memory: 8* 32GB DDR4-2933.
720 - Disks: 1* 1TB SATA SSD.
721 - NICs configuration:
722 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
723 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
724 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
725 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
726 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
728 - Physical connectivity:
729 - IPMI and host management ports.
730 - NIC ports connected into 2-node testbed topologies.
731 - Main HW configuration:
732 - Chassis: SuperMicro AS-1114S-WTRT
733 - Processors: 1* AMD EPYC 7532 2.4 GHz.
734 - RAM Memory: 8* 32GB DDR4-2933.
735 - Disks: 1* 1TB SATA SSD.
736 - NICs configuration:
737 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
738 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
739 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
740 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
741 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
743 - Physical connectivity:
744 - IPMI and host management ports.
745 - NIC ports connected into 1-node topologies.
746 - Main HW configuration:
747 - Chassis: GIGABYTE Rack Mount
748 - Motherboard: MT91-FS4-00
749 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
750 - RAM Memory: 16 * 16GB DIMM
751 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
752 - NICs configuration:
754 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
755 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
757 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
758 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
759 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
761 - Physical connectivity:
762 - IPMI(?) and host management ports.
763 - NIC ports connected into 3-node topology.
764 - Main HW configuration:
765 - Chassis: Huawei TaiShan 2280.
766 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
767 - RAM Memory: 8* 16GB DDR4-2400MT/s
768 - Disks: 1* 4TB SATA HDD
769 - NICs configuration:
770 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
771 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
772 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
774 - Physical connectivity:
775 - IPMI and host management ports.
776 - NIC ports connected into 2-node topologies.
777 - Main HW configuration:
778 - Chassis: Gigabyte R181-T90 1U
779 - Motherboard: MT91-FS1
780 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
781 - RAM Memory: 4* 32GB RDIMM
782 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
783 - NICs configuration:
787 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
788 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
790 - Physical connectivity:
791 - IPMI and host management ports.
792 - NIC ports connected into 3-node topologies.
793 - Main HW configuration:
794 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
795 - Motherboard: Mt.Jade Motherboard
796 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
797 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
798 - RAM Memory: 16* 8GB DDR4-3200MT/s
799 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
800 - NICs configuration:
802 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
805 21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
807 - Physical connectivity:
808 - IPMI and host management ports.
809 - Main HW configuration:
810 - Chassis: Gigabyte R152-P30-00 1U
811 - Motherboard: MP32-AR1-00
812 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
813 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
814 - RAM Memory: 12* 16GB DDR4-3200MT/s
815 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
816 22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
818 - Physical connectivity:
819 - IPMI and host management ports.
820 - NIC ports connected into 2-node and 3-node topologies.
821 - Main HW configuration:
822 - Chassis: SuperMicro SYS-7049GP-TRT.
823 - Motherboard: SuperMicro X11DPG-QT.
824 - Processors: 2* Intel Platinum 8180 2.5 GHz.
825 - RAM Memory: 16* 16GB DDR4-2666MHz.
826 - Disks: 2* 1.6TB 6G SATA SSD.
827 - NICs configuration:
828 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
829 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
830 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
831 - PCIe Slot9 5e:00.xx: empty.
832 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
833 - PCIe Slot6 86:00.xx: empty.
834 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
835 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
836 23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
838 - Physical connectivity:
839 - IPMI and host management ports.
840 - NIC ports connected into 2-node or 3-node testbed topologies.
841 - Main HW configuration:
842 - Chassis: SuperMicro SYS-740GP-TNRT.
843 - Motherboard: Super X12DPG-QT6.
844 - Processors: 2* Intel Platinum 8358 2.6 GHz.
845 - RAM Memory: 16* 16GB DDR4-3200.
846 - Disks: 2* 960GB SATA SSD.
847 - NICs configuration:
848 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
849 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
850 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
851 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
852 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
853 - PCIe Slot6 86:00.xx: empty.
854 - PCIe Slot8 af:00.xx: empty.
855 - PCIe Slot10 d8:00.xx: empty.
856 24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
858 - Physical connectivity:
859 - IPMI and host management ports.
860 - NIC ports connected into 2-node testbed topologies.
861 - Main HW configuration:
862 - Chassis: SuperMicro SYS-740GP-TNRT.
863 - Motherboard: Super X12DPG-QT6.
864 - Processors: 2* Intel Platinum 8358 2.6 GHz.
865 - RAM Memory: 16* 16GB DDR4-3200.
866 - Disks: 2* 960GB SATA SSD.
867 - NICs configuration:
868 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
869 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
870 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
871 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
872 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
873 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
874 - PCIe Slot8 af:00.xx: empty.
875 - PCIe Slot10 d8:00.xx: empty.
876 25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
878 - Physical connectivity:
879 - IPMI and host management ports.
880 - NIC ports connected into 3-node testbed topologies.
881 - Main HW configuration:
882 - Chassis: SuperMicro SYS-740GP-TNRT.
883 - Motherboard: Super X12DPG-QT6.
884 - Processors: 2* Intel Platinum 8358 2.6 GHz.
885 - RAM Memory: 16* 16GB DDR4-3200.
886 - Disks: 2* 960GB SATA SSD.
887 - NICs configuration:
888 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
889 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
890 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
891 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
892 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
893 - PCIe Slot6 86:00.xx: empty.
894 - PCIe Slot8 af:00.xx: empty.
895 - PCIe Slot10 d8:00.xx: empty.
896 26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
898 - Physical connectivity:
899 - IPMI and host management ports.
900 - NIC ports connected into 2-node and/or 3-node testbed topologies.
901 - Main HW configuration:
902 - Chassis: SuperMicro SYS-740GP-TNRT.
903 - Motherboard: Super X12DPG-QT6.
904 - Processors: 2* Intel Platinum 8358 2.6 GHz.
905 - RAM Memory: 16* 16GB DDR4-3200.
906 - Disks: 2* 960GB SATA SSD.
907 - NICs configuration:
908 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
909 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
910 - PCIe Slot4 3b:00.xx: empty.
911 - PCIe Slot9 5e:00.xx: empty.
912 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
913 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
914 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
915 - PCIe Slot10 d8:00.xx: empty.
916 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
918 - Physical connectivity:
919 - IPMI and host management ports.
920 - NIC ports connected into 3-node testbed topology.
921 - Main HW configuration:
922 - Chassis: Intel JACOBSVILLE SDP.
923 - Motherboard: Intel JACOBSVILLE E63448-400.
924 - Processors: 1* Intel Atom P5362B 2.2 GHz.
925 - RAM Memory: 2* 16GB DDR4-2933.
926 - Disks: ?* ? SATA SSD.
927 - NICs configuration:
928 - Numa0: (x16, PCIe3.0 lane)
929 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
932 ### Naming Convention
934 Following naming convention is used within this page to specify physical
935 connectivity and wiring across defined CSIT testbeds:
938 - testbedname: testbedN.
940 - traffic-generator: tN-tgW.
941 - system-under-testX: tN-sutX.
946 - N - testbed number.
947 - tgW - server acts as traffic-generator with W index.
948 - sutX - server acts as system-under-test with X index.
949 - Y - PCIe slot number denoting a NIC card number within the host.
950 - Z - port number on the NIC card.
953 ## Testbeds Configuration
955 ### Per Testbed Server Allocation and Naming
957 #### 1-Node-Skylake Servers (1n-skx) PROD
960 - SUT [Server-Type-B6]:
961 - testbedname: testbed11.
962 - hostname: s1-t11-sut1.
963 - IPMI IP: 10.30.50.47
964 - Host IP: 10.30.51.50
966 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
967 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
968 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
969 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
970 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
971 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
972 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
973 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
974 - SUT [Server-Type-B6]:
975 - testbedname: testbed12.
976 - hostname: s2-t12-sut1.
977 - IPMI IP: 10.30.50.48
978 - Host IP: 10.30.51.51
980 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
981 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
982 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
983 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
984 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
985 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
986 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
987 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
990 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
993 - SUT [Server-Type-E11]:
994 - testbedname: testbed13
995 - hostname: s55-t13-sut1
996 - IPMI IP: 10.30.50.70
997 - Host IP: 10.30.51.70
999 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1000 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1001 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1002 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1003 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1004 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1005 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1006 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1007 - SUT [Server-Type-E11]:
1008 - testbedname: testbed14
1009 - hostname: s56-t14-sut1
1010 - IPMI IP: 10.30.50.71
1011 - Host IP: 10.30.51.71
1013 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1014 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1015 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1016 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1017 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1018 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1019 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1020 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1023 #### 1-Node-Cascadelake Servers (1n-clx) PROD
1026 - SUT [Server-Type-C1]:
1027 - testbedname: testbed11.
1028 - hostname: s32-t14-sut1.
1029 - IPMI IP: 10.30.55.17
1030 - Host IP: 10.32.8.17
1032 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1033 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1034 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1035 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1036 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1037 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1038 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1039 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1042 #### 2-Node-Skylake Servers (2n-skx) PROD
1045 - SUT [Server-Type-B1]:
1046 - testbedname: testbed21.
1047 - hostname: s3-t21-sut1.
1048 - IPMI IP: 10.30.50.41
1049 - Host IP: 10.30.51.44
1051 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1052 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1053 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1054 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1055 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1056 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1057 - TG [Server-Type-B2]:
1058 - testbedname: testbed21.
1059 - hostname: s4-t21-tg1.
1060 - IPMI IP: 10.30.50.42
1061 - Host IP: 10.30.51.45
1063 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1064 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1065 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1066 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1067 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1068 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1069 - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1070 - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1071 - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1072 - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1073 - SUT [Server-Type-B1]:
1074 - testbedname: testbed22.
1075 - hostname: s5-t22-sut1.
1076 - IPMI IP: 10.30.50.49
1077 - Host IP: 10.30.51.52
1079 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1080 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1081 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1082 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1083 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1084 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1085 - TG [Server-Type-B2]:
1086 - testbedname: testbed22.
1087 - hostname: s6-t22-tg1.
1088 - IPMI IP: 10.30.50.50
1089 - Host IP: 10.30.51.53
1091 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1092 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1093 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1094 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1095 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1096 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1097 - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1098 - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1099 - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1100 - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1101 - SUT [Server-Type-B1]:
1102 - testbedname: testbed23.
1103 - hostname: s7-t23-sut1.
1104 - IPMI IP: 10.30.50.51
1105 - Host IP: 10.30.51.54
1107 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1108 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1109 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1110 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1111 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1112 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1113 - TG [Server-Type-B2]:
1114 - testbedname: testbed23.
1115 - hostname: s8-t23-tg1.
1116 - IPMI IP: 10.30.50.52
1117 - Host IP: 10.30.51.55
1119 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1120 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1121 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1122 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1123 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1124 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1125 - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1126 - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1127 - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1128 - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1129 - SUT [Server-Type-B1]:
1130 - testbedname: testbed24.
1131 - hostname: s9-t24-sut1.
1132 - IPMI IP: 10.30.50.53
1133 - Host IP: 10.30.51.56
1135 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1136 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1137 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1138 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1139 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1140 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1141 - TG [Server-Type-B2]:
1142 - testbedname: testbed24.
1143 - hostname: s10-t24-tg1.
1144 - IPMI IP: 10.30.50.54
1145 - Host IP: 10.30.51.57
1147 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1148 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1149 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1150 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1151 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1152 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1153 - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1154 - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1155 - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1156 - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1159 #### 2-Node-Denverton Servers (2n-dnv) PROD
1161 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1164 - TG [Server-Type-B2]:
1165 - testbednames: testbed26 and testbed35.
1166 - hostname: s28-t26t35-tg1.
1167 - IPMI IP: 10.30.55.10
1168 - Host IP: 10.32.8.10
1170 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1171 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1172 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1173 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1174 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1175 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1176 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1177 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1178 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1179 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1180 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1181 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1182 - SUT [Server-Type-B10]:
1183 - testbednames: testbed26.
1184 - hostname: s29-t26-sut1.
1185 - IPMI IP: 10.30.55.11
1186 - Host IP: 10.32.8.11
1188 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1189 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1190 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1191 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1194 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1197 - SUT [Server-Type-B8]:
1198 - testbedname: testbed25.
1199 - hostname: s25-t25-sut1.
1200 - IPMI IP: 10.30.50.58
1201 - Host IP: 10.30.51.61
1203 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1204 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1205 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1206 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1207 - TG [Server-Type-B7]:
1208 - testbedname: testbed25.
1209 - hostname: s26-t25-tg1.
1210 - IPMI IP: 10.30.50.59
1211 - Host IP: 10.30.51.62
1213 - s26-t25-tg1-p1 - 10GE-port1.
1214 - s26-t25-tg1-p2 - 10GE-port2.
1215 - s26-t25-tg1-p3 - 10GE-port3.
1216 - s26-t25-tg1-p4 - 10GE-port4.
1219 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1222 - SUT [Server-Type-C2]:
1223 - testbedname: testbed27.
1224 - hostname: s33-t27-sut1.
1225 - IPMI IP: 10.30.55.18
1226 - Host IP: 10.32.8.18
1228 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1229 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1230 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1231 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1232 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1233 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1234 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1235 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1236 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1237 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1238 - TG [Server-Type-C3]:
1239 - testbedname: testbed27.
1240 - hostname: s34-t27-tg1.
1241 - IPMI IP: 10.30.55.19
1242 - Host IP: 10.32.8.19
1244 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1245 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1246 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1247 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1248 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1249 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1250 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1251 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1252 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1253 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1254 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1255 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1256 - SUT [Server-Type-C2]:
1257 - testbedname: testbed28.
1258 - hostname: s35-t28-sut1.
1259 - IPMI IP: 10.30.55.20
1260 - Host IP: 10.32.8.20
1262 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1263 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1264 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1265 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1266 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1267 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1268 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1269 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1270 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1271 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1272 - TG [Server-Type-C3]:
1273 - testbedname: testbed28.
1274 - hostname: s36-t28-tg1.
1275 - IPMI IP: 10.30.55.21
1276 - Host IP: 10.32.8.21
1278 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1279 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1280 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1281 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1282 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1283 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1284 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1285 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1286 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1287 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1288 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1289 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1290 - SUT [Server-Type-C2]:
1291 - testbedname: testbed29.
1292 - hostname: s37-t29-sut1.
1293 - IPMI IP: 10.30.55.22
1294 - Host IP: 10.32.8.22
1296 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1297 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1298 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1299 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1300 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1301 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1302 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1303 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1304 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1305 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1306 - TG [Server-Type-C3]:
1307 - testbedname: testbed29.
1308 - hostname: s38-t29-tg1.
1309 - IPMI IP: 10.30.55.23
1310 - Host IP: 10.32.8.23
1312 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1313 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1314 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1315 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1316 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1317 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1318 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1319 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1320 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1321 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1324 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1327 - SUT [Server-Type-D1]:
1328 - testbedname: testbed210.
1329 - hostname: s60-t210-sut1.
1330 - IPMI IP: 10.30.55.24
1331 - Host IP: 10.32.8.24
1333 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1334 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1335 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1336 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1337 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1338 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1339 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1340 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1341 - TG [Server-Type-D2]:
1342 - testbedname: testbed210.
1343 - hostname: s61-t210-tg1.
1344 - IPMI IP: 10.30.55.25
1345 - Host IP: 10.32.8.25
1347 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1348 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1349 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1350 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1351 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1352 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1353 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1354 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1357 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1359 Note: Server19 (TG) is shared between testbed33 & testbed211
1362 - SUT [Server-Type-E22]:
1363 - testbedname: testbed211.
1364 - hostname: s27-t211-sut1.
1365 - IPMI IP: 10.30.50.69
1366 - Host IP: 10.30.51.69
1368 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1369 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1370 - TG [Server-Type-E31]:
1371 - testbedname: testbed33 and testbed211.
1372 - hostname: s19-t33t211-tg1.
1373 - IPMI IP: 10.30.50.46
1374 - Host IP: 10.30.51.49
1376 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1377 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1378 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1379 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1380 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1381 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1382 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1383 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1384 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1385 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1386 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1387 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1390 #### 2-Node-Icelake Servers (2n-icx) PROD
1393 - SUT [Server-Type-F1]:
1394 - testbedname: testbed212.
1395 - hostname: s71-t212-sut1.
1396 - IPMI IP: 10.30.51.81
1397 - Host IP: 10.30.50.81
1399 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1400 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1401 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1402 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1403 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1404 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1405 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1406 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1407 - TG [Server-Type-F2]:
1408 - testbedname: testbed212.
1409 - hostname: s72-t212-tg1.
1410 - IPMI IP: 10.30.51.82
1411 - Host IP: 10.30.50.82
1413 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1414 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1415 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1416 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1417 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1418 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1419 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1420 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1421 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1422 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1423 - SUT [Server-Type-F1]:
1424 - testbedname: testbed213.
1425 - hostname: s83-t213-sut1.
1426 - IPMI IP: 10.30.51.83
1427 - Host IP: 10.30.50.83
1429 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1430 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1431 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1432 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1433 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1434 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1435 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1436 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1437 - TG [Server-Type-F2]:
1438 - testbedname: testbed213.
1439 - hostname: s84-t213-tg1.
1440 - IPMI IP: 10.30.51.84
1441 - Host IP: 10.30.50.84
1443 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1444 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1445 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1446 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1447 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1448 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1449 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1450 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1451 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1452 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1453 - SUT [Server-Type-F1]:
1454 - testbedname: testbed214.
1455 - hostname: s85-t214-sut1.
1456 - IPMI IP: 10.30.51.85
1457 - Host IP: 10.30.50.85
1459 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1460 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1461 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1462 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1463 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1464 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1465 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1466 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1467 - TG [Server-Type-F2]:
1468 - testbedname: testbed214.
1469 - hostname: s86-t214-tg1.
1470 - IPMI IP: 10.30.51.86
1471 - Host IP: 10.30.50.86
1473 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1474 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1475 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1476 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1477 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1478 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1479 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1480 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1481 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1482 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1483 - SUT [Server-Type-F1]:
1484 - testbedname: testbed215.
1485 - hostname: s87-t215-sut1.
1486 - IPMI IP: 10.30.51.87
1487 - Host IP: 10.30.50.87
1489 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1490 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1491 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1492 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1493 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1494 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1495 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1496 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1497 - TG [Server-Type-F2]:
1498 - testbedname: testbed215.
1499 - hostname: s88-t215-tg1.
1500 - IPMI IP: 10.30.51.88
1501 - Host IP: 10.30.50.88
1503 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1504 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1505 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1506 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1507 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1508 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1509 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1510 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1511 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1512 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1515 #### 3-Node-Skylake Servers (3n-skx) PROD
1518 - ServerB11 [Server-Type-B1]:
1519 - testbedname: testbed31.
1520 - hostname: s11-t31-sut1.
1521 - IPMI IP: 10.30.50.43
1522 - Host IP: 10.30.51.46
1524 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1525 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1526 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1527 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1528 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1529 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1530 - ServerB12 [Server-Type-B1]:
1531 - testbedname: testbed31.
1532 - hostname: s12-t31-sut2.
1533 - IPMI IP: 10.30.50.44
1534 - Host IP: 10.30.51.47
1536 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1537 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1538 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1539 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1540 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1541 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1542 - ServerB13 [Server-Type-B2]:
1543 - testbedname: testbed31.
1544 - hostname: s13-t31-tg1.
1545 - IPMI IP: 10.30.50.45
1546 - Host IP: 10.30.51.48
1548 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1549 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1550 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1551 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1552 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1553 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1554 - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1555 - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1556 - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1557 - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1558 - ServerB14 [Server-Type-B1]:
1559 - testbedname: testbed32.
1560 - hostname: s14-t32-sut1.
1561 - IPMI IP: 10.30.50.55
1562 - Host IP: 10.30.51.58
1564 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1565 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1566 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1567 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1568 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1569 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1570 - ServerB15 [Server-Type-B1]:
1571 - testbedname: testbed32.
1572 - hostname: s15-t32-sut2.
1573 - IPMI IP: 10.30.50.56
1574 - Host IP: 10.30.51.59
1576 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1577 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1578 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1579 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1580 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1581 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1582 - ServerB16 [Server-Type-B2]:
1583 - testbedname: testbed32.
1584 - hostname: s16-t32-tg1.
1585 - IPMI IP: 10.30.50.57
1586 - Host IP: 10.30.51.60
1588 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1589 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1590 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1591 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1592 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1593 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1594 - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1595 - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1596 - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1597 - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1600 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1602 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1605 - ServerB22 [Server-Type-B5]:
1606 - testbedname: testbed35.
1607 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1608 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1609 - Host IP: 10.30.51.9
1611 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1612 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1614 - ServerB23 [Server-Type-B5]:
1615 - testbedname: testbed35.
1616 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1617 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1618 - Host IP: 10.30.51.10
1620 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1621 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1623 - ServerB24 [Server-Type-B5]:
1624 - testbedname: testbed35.
1625 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1626 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1627 - Host IP: 10.30.51.11
1629 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1630 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1634 #### 3-Node-Taishan Servers (3n-tsh) PROD
1636 Note: Server19 (TG) is shared between testbed33 & testbed211
1639 - SUT [Server-Type-E21]:
1640 - testbedname: testbed33.
1641 - hostname: s17-t33-sut1.
1642 - IPMI IP: 10.30.50.36
1643 - Host IP: 10.30.51.36
1645 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1646 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1647 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1648 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1649 - SUT [Server-Type-E21]:
1650 - testbedname: testbed33.
1651 - hostname: s18-t33-sut2.
1652 - IPMI IP: 10.30.50.37
1653 - Host IP: 10.30.51.37
1655 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1656 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1657 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1658 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1659 - TG [Server-Type-E31]:
1660 - testbedname: testbed33 and testbed211.
1661 - hostname: s19-t33t211-tg1.
1662 - IPMI IP: 10.30.50.46
1663 - Host IP: 10.30.51.49
1665 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1666 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1667 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1668 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1669 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1670 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1671 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1672 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1673 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1674 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1675 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1676 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1679 #### 3-Node-Altra Servers (3n-alt) PROD
1682 - SUT [Server-Type-E23]:
1683 - testbedname: testbed34.
1684 - hostname: s62-t34-sut1.
1685 - IPMI IP: 10.30.50.72
1686 - Host IP: 10.30.51.72
1688 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1689 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1690 - SUT [Server-Type-E23]:
1691 - testbedname: testbed34.
1692 - hostname: s63-t34-sut2.
1693 - IPMI IP: 10.30.50.73
1694 - Host IP: 10.30.51.73
1696 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1697 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1698 - TG [Server-Type-F4]:
1699 - testbedname: testbed34.
1700 - hostname: s64-t34-tg1.
1701 - IPMI IP: 10.30.50.74
1702 - Host IP: 10.30.51.74
1704 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1705 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1706 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1707 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1708 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1709 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1710 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1711 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1712 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1713 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1716 #### 3-Node-Denverton Servers (3n-dnv) PROD
1719 - ServerB30 [Server-Type-B10]:
1720 - testbednames: testbed35.
1721 - hostname: s30-t35-sut1.
1722 - IPMI IP: 10.30.55.12
1723 - Host IP: 10.32.8.12
1725 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1726 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1727 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1728 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1729 - ServerB31 [Server-Type-B10]:
1730 - testbednames: testbed35.
1731 - hostname: s31-t35-sut2.
1732 - IPMI IP: 10.30.55.13
1733 - Host IP: 10.32.8.13
1735 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1736 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1737 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1738 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1741 #### 3-Node-Icelake Servers (3n-icx) PROD
1744 - ServerF1 [Server-Type-F1]:
1745 - testbedname: testbed37.
1746 - hostname: s65-t37-sut1.
1747 - IPMI IP: 10.30.50.75
1748 - Host IP: 10.30.51.75
1750 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1751 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1752 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1753 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1754 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1755 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1756 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1757 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1758 - ServerF1 [Server-Type-F1]:
1759 - testbedname: testbed37.
1760 - hostname: s66-t37-sut2.
1761 - IPMI IP: 10.30.50.76
1762 - Host IP: 10.30.51.76
1764 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1765 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1766 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1767 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1768 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1769 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1770 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1771 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1772 - ServerF3 [Server-Type-F3]:
1773 - testbedname: testbed37.
1774 - hostname: s67-t37-tg1.
1775 - IPMI IP: 10.30.50.77
1776 - Host IP: 10.30.51.77
1778 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1779 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1780 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1781 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1782 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1783 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1784 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1785 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1786 - ServerF1 [Server-Type-F1]:
1787 - testbedname: testbed38.
1788 - hostname: s78-t38-sut1.
1789 - IPMI IP: 10.30.50.78
1790 - Host IP: 10.30.51.78
1792 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1793 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1794 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1795 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1796 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1797 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1798 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1799 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1800 - ServerF1 [Server-Type-F1]:
1801 - testbedname: testbed38.
1802 - hostname: s79-t38-sut2.
1803 - IPMI IP: 10.30.50.79
1804 - Host IP: 10.30.51.79
1806 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1807 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1808 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1809 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1810 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1811 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1812 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1813 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1814 - ServerF3 [Server-Type-F3]:
1815 - testbedname: testbed38.
1816 - hostname: s80-t38-tg1.
1817 - IPMI IP: 10.30.50.80
1818 - Host IP: 10.30.51.80
1820 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1821 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1822 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1823 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1824 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1825 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1826 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1827 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1830 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1833 - ServerG1 [Server-Type-G1]:
1834 - testbedname: testbed39.
1835 - hostname: s93-t39-sut1.
1836 - IPMI IP: 10.30.50.93
1837 - Host IP: 10.30.51.93
1839 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1840 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1841 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1842 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1843 - ServerG1 [Server-Type-G1]:
1844 - testbedname: testbed39.
1845 - hostname: s94-t39-sut2.
1846 - IPMI IP: 10.30.50.94
1847 - Host IP: 10.30.51.94
1849 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1850 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1851 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1852 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1853 - ServerF4 [Server-Type-F4]:
1854 - testbedname: testbed39.
1855 - hostname: s89-t39t310-tg1.
1856 - IPMI IP: 10.30.50.89
1857 - Host IP: 10.30.51.89
1859 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1860 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1861 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1862 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1865 ### Per Testbed Wiring
1867 #### 1-Node-Skylake Wiring (1n-skx) PROD
1871 - ring1 10GE-ports x710-4p10GE:
1872 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1873 - ring2 10GE-ports x710-4p10GE:
1874 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1875 - ring3 10GE-ports x710-4p10GE:
1876 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1877 - ring4 10GE-ports x710-4p10GE:
1878 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1879 - ring5 100GE-ports e810-2p100GE:
1880 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1881 - ring6 100GE-ports e810-2p100GE:
1882 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1884 - ring1 10GE-ports x710-4p10GE:
1885 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1886 - ring2 10GE-ports x710-4p10GE:
1887 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1888 - ring3 10GE-ports x710-4p10GE:
1889 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1890 - ring4 10GE-ports x710-4p10GE:
1891 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1892 - ring5 100GE-ports e810-2p100GE:
1893 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1894 - ring6 100GE-ports e810-2p100GE:
1895 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1898 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1902 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1903 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1904 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1905 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1906 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1907 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1908 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1909 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1912 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1913 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1914 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1915 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1916 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1917 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1918 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1919 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1922 #### 2-Node-Skylake Wiring (2n-skx) PROD
1926 - ring1 10GE-ports x710-4p10GE on SUT:
1927 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1928 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1929 - ring2 10GE-ports x710-4p10GE on SUT:
1930 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1931 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1932 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1933 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1934 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1935 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1936 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1937 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1939 - ring1 10GE-ports x710-4p10GE on SUT:
1940 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1941 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1942 - ring2 10GE-ports x710-4p10GE on SUT:
1943 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1944 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1945 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1946 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1947 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1948 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1949 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1950 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1952 - ring1 10GE-ports x710-4p10GE on SUT:
1953 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1954 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1955 - ring2 10GE-ports x710-4p10GE on SUT:
1956 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1957 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1958 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1959 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1960 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1961 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1962 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1963 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1965 - ring1 10GE-ports x710-4p10GE on SUT:
1966 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1967 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1968 - ring2 10GE-ports x710-4p10GE on SUT:
1969 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1970 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1971 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1972 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1973 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1974 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1975 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1976 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1979 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1983 - ring1 10GE-ports x553 copper port on SUT:
1984 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1985 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1986 - ring2 10GE-ports x553 fiber port on SUT:
1987 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1988 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1991 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1995 - link1 10GE-port x710-4p10GE on SUT:
1996 - t25-tg1-p1 to t25-sut1-c2/p1.
1997 - link2 10GE-port x710-4p10GE on SUT:
1998 - t25-tg1-p2 to t25-sut1-c2/p2.
1999 - link3 10GE-port x710-4p10GE on SUT:
2000 - t25-tg1-p3 to t25-sut1-c2/p3.
2001 - link4 10GE-port x710-4p10GE on SUT:
2002 - t25-tg1-p4 to t25-sut1-c2/p4.
2005 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
2009 - ring1 10GE-ports x710-4p10GE on SUT:
2010 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
2011 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
2012 - ring2 10GE-ports x710-4p10GE on SUT:
2013 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
2014 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
2015 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2016 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
2017 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
2018 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2019 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
2020 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
2021 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2022 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
2023 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
2024 - ring6 100GE-ports e810-2p100GE on TG:
2025 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
2026 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
2028 - ring1 10GE-ports x710-4p10GE on SUT:
2029 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
2030 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
2031 - ring2 10GE-ports x710-4p10GE on SUT:
2032 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
2033 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
2034 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2035 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
2036 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
2037 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2038 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
2039 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
2040 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2041 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
2042 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
2043 - ring6 100GE-ports e810-2p100GE on TG:
2044 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
2045 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
2047 - ring1 10GE-ports x710-4p10GE on SUT:
2048 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
2049 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
2050 - ring2 10GE-ports x710-4p10GE on SUT:
2051 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
2052 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
2053 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2054 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
2055 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
2056 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2057 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
2058 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
2059 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2060 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
2061 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
2064 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
2068 - ring1 10GE-ports x710-4p10GE on SUT:
2069 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
2070 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
2071 - ring2 10GE-ports x710-4p10GE on SUT:
2072 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
2073 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
2074 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2075 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
2076 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
2077 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2078 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
2079 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
2082 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
2086 - ring1 10GE-ports x520-2p10GE on SUTs:
2087 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
2088 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
2091 #### 2-Node-Icelake Wiring (2n-icx) PROD
2095 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2096 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
2097 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
2098 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2099 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
2100 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
2101 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
2102 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
2103 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2104 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
2105 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
2106 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2107 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
2108 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
2110 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2111 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
2112 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
2113 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2114 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
2115 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
2116 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
2117 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
2118 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2119 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
2120 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
2121 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2122 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
2123 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
2125 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2126 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
2127 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
2128 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2129 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
2130 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
2131 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
2132 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
2133 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2134 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
2135 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
2136 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2137 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
2138 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
2140 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2141 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
2142 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
2143 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2144 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
2145 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
2146 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
2147 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
2148 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2149 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
2150 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
2151 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2152 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
2153 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
2156 #### 3-Node-Skylake Wiring (3n-skx) PROD
2160 - ring1 10GE-ports x710-4p10GE on SUTs:
2161 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
2162 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
2163 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
2164 - ring2 10GE-ports x710-4p10GE on SUT:
2165 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
2166 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
2167 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
2168 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2169 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
2170 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
2171 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
2172 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2173 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
2174 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
2175 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
2176 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2177 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
2178 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
2180 - ring1 10GE-ports x710-4p10GE on SUTs:
2181 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
2182 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
2183 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
2184 - ring2 10GE-ports x710-4p10GE on SUT:
2185 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
2186 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
2187 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
2188 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2189 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
2190 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
2191 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
2192 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2193 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
2194 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
2195 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
2196 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2197 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
2198 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
2201 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
2207 #### 3-Node-Taishan Wiring (3n-tsh) PROD
2211 - ring1 10GE-ports x520-2p10GE on SUTs:
2212 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
2213 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
2214 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
2215 - ring2 25GE-ports cx4-2p25GE on SUTs:
2216 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
2217 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
2218 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
2221 #### 3-Node-Altra Wiring (3n-alt) PROD
2225 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
2226 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
2227 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
2228 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
2231 #### 3-Node-Denverton Wiring (3n-dnv) PROD
2235 - ring1 10GE-ports x553 copper port on SUTs:
2236 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
2237 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
2238 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
2239 - ring2 10GE-ports x553 fiber port on SUTs:
2240 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
2241 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
2242 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
2245 #### 3-Node-Icelake Wiring (3n-icx) PROD
2249 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2250 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
2251 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
2252 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
2253 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2254 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
2255 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
2256 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
2257 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
2258 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
2259 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
2260 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2261 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
2262 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
2263 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
2265 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2266 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
2267 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
2268 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
2269 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2270 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
2271 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
2272 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
2273 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
2274 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
2275 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
2276 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2277 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
2278 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
2279 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
2282 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
2286 - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
2287 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
2288 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
2289 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
2290 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
2291 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
2292 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
2300 1. Ixia PerfectStorm One Appliance
2302 - Chassis: PS10GE4NG.
2303 - Motherboard: SuperMicro X11DPG-QT.
2304 - Processors: Quad-Core, Intel Processor.
2305 - HW accelerators: FPGA offload.
2307 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
2308 - Physical Interfaces: 4 * 10GE SFP+.
2309 - Operating System: Native IxOS.
2315 1. Arm Cortex A-72 servers
2316 - 2 * ThunderX2 (VPP Device)
2317 - Chassis: GIGABYTE Rack Mount
2318 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
2319 - RAM Memory: 16* 16GB DIMM
2320 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
2321 - 1 * ThunderX2 (Performance)
2322 - Chassis: GIGABYTE Rack Mount
2323 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
2324 - RAM Memory: 4* 32GB RDIMM
2325 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
2326 - 2 * Huawei TaiShan 2280.
2327 - Chassis: Huawei TaiShan 2280.
2328 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
2329 - RAM Memory: 8* 16GB DDR4-2400MT/s.
2330 - Disks: 1* 4TB SATA HDD.
2331 2. Arm Neoverse N1 servers
2332 - 2 * Ampere Altra (Performance)
2333 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
2334 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
2335 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
2336 - RAM Memory: 16* 8GB DDR4-3200MT/s
2337 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
2338 - 2 * Ampere Altra (Build)
2339 - Chassis: Gigabyte R152-P30-00 1U
2340 - Motherboard: MP32-AR1-00
2341 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
2342 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
2343 - RAM Memory: 12* 16GB DDR4-3200MT/s
2344 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
2347 ### Xeon and Atom Servers
2350 1. Intel Xeon servers:
2351 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
2352 - Chassis: SuperMicro SYS-7049GP-TRT.
2353 - Motherboard: SuperMicro X11DPG-QT.
2354 - Processors: 2* Intel Platinum 8180 2.5 GHz.
2355 - RAM Memory: 16* 16GB DDR4-2666MHz.
2356 - Disks: 2* 1.6TB 6G SATA SSD.
2357 2. Intel Atom servers with Rangely processors.
2358 - 3 * Netgate XG-2758-1u
2359 - Chassis: Netgate XG-2758-1u
2360 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
2361 - RAM Memory: 16GB ECC
2365 ### Network Interface Cards
2378 ### Pluggables and Cables