1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
9 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
10 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
11 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
12 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
13 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
14 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
15 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
16 1. [Server Management](#server-management)
17 1. [Requirements](#requirements)
18 1. [Addressing](#addressing)
19 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
20 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
21 1. [Server Type Specification](#server-type-specification)
22 1. [Server and Port Naming](#server-and-port-naming)
23 1. [Testbeds Configuration](#testbeds-configuration)
24 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
25 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
26 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
27 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
28 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
29 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
30 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
31 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
32 1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
33 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
34 1. [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
35 1. [Per Testbed Wiring](#per-testbed-wiring)
36 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
37 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
38 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
39 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
40 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
41 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
42 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
43 1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
44 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
45 1. [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
46 1. [Inventory](#inventory)
47 1. [Appliances](#appliances)
48 1. [Arm Servers](#arm-servers)
49 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
50 1. [Network Interface Cards](#network-interface-cards)
51 1. [Pluggables and Cables](#pluggables-and-cables)
52 1. [Other Parts](#other-parts)
56 This note includes specification of the physical testbed infrastructure
57 hosted by LFN FD.io CSIT project.
64 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
65 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0
66 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0
67 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
68 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
69 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
70 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
71 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
72 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
73 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
74 10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
75 11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0
76 Totals: 17 26 14 12 19 1 2 1 1 2 2
79 ### 1-Node-Skylake Xeon Intel (1n-skx)
81 Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
82 ports connected back-to-back.
83 Used for FD.io VPP_Device functional driver tests.
85 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
87 Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
88 ports connected back-to-back.
89 Used for FD.io VPP_Device functional driver tests.
91 ### 2-Node-Skylake Xeon Intel (2n-skx)
93 Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
94 (Type-B2 server) connected back-to-back.
95 Used for FD.io performance tests.
97 ### 2-Node-Denverton Atom Intel (2n-dnv)
99 Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
100 (Type-B2 server) connected back-to-back.
101 Used for FD.io performance tests.
103 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
105 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
106 TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
107 Used for FD.io TCP/IP and HTTP performance tests.
109 ### 3-Node-Haswell Xeon Intel (3n-hsw)
111 Each 3-Node-Haswell testbed includes two SUTs (Type-A1 servers) and one
112 TG (Type-A2 server) connected in full-mesh triangle.
113 Used for FD.io performance tests.
115 ### 3-Node-Skylake Xeon Intel (3n-skx)
117 Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
118 TG (Type-B2 server) connected in full-mesh triangle.
119 Used for FD.io performance tests.
121 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
123 Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
124 (Type-B2 server) connected in full-mesh triangle.
125 Used for FD.io performance tests.
127 ### 3-Node-MACCHIATObin Arm Marvell
129 Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
130 one TG (Type-B2 server) connected in full-mesh triangle.
131 Used for FD.io performance tests.
133 ### 3-Node-Rangeley Atom Testbeds
135 Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
136 and one TG (Type-2 server) connected in full-mesh triangle.
137 Used for FD.io performance tests.
143 For management purposes, each server must have following two ports
144 connected to the management network:
148 - IPMI - Intelligent Platform Management Interface.
149 - Required for access to embedded server management with WebUI, CLI, SNMPv3,
150 IPMIv2.0, for firmware (BIOS) and OS updates.
151 - 1GE/10GE/40GE management port
152 - hostOS management port for general system management.
157 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
158 port, which are connected to two different VLANs.
162 - Subnet: 10.30.50.0/24
163 - Gateway: 10.30.50.1
164 - Broadcast: 10.30.50.255
165 - DNS1: 199.204.44.24
166 - DNS2: 199.204.47.54
168 - Subnet: 10.30.51.0/24
169 - Gateway: 10.30.51.1
170 - Broadcast: 10.30.51.255
171 - DNS1: 199.204.44.24
172 - DNS2: 199.204.47.54
175 To access these hosts, VPN connection is required.
177 ### LOM (IPMI) VLAN IP Addresses
180 ------------ | -------
183 10.30.50.2 | LF Reserved
184 10.30.50.3 | LF Reserved
185 10.30.50.4 | LF Reserved
186 10.30.50.5 | LF Reserved
187 10.30.50.6 | LF Reserved
188 10.30.50.7 | LF Reserved
189 10.30.50.8 | LF Reserved
190 10.30.50.9 | LF Reserved
191 10.30.50.10 | LF Reserved
192 10.30.50.11 | LF Reserved
193 10.30.50.12 | LF Reserved
194 10.30.50.13 | LF Reserved
195 10.30.50.14 | LF Reserved
196 10.30.50.15 | LF Reserved
198 10.30.50.17 | t1-sut1
199 10.30.50.18 | t1-sut2
201 10.30.50.21 | t2-sut1
202 10.30.50.22 | t2-sut2
204 10.30.50.25 | t3-sut1
205 10.30.50.26 | t3-sut-2
206 10.30.50.28 | t4-sut1
207 10.30.50.29 | t4-sut2
208 10.30.50.30 | t4-sut3
209 10.30.50.36 | s17-t33-sut1
210 10.30.50.37 | s18-t33-sut2
211 10.30.50.41 | s3-t21-sut1
212 10.30.50.42 | s4-t21-tg1
213 10.30.50.43 | s11-t31-sut1
214 10.30.50.44 | s12-t31-sut2
215 10.30.50.45 | s13-t31-tg1
216 10.30.50.46 | s19-t33t34-tg1
217 10.30.50.47 | s1-t11-sut1
218 10.30.50.48 | s2-t12-sut1
219 10.30.50.49 | s5-t22-sut1
220 10.30.50.50 | s6-t22-tg1
221 10.30.50.51 | s7-t23-sut1
222 10.30.50.52 | s8-t23-tg1
223 10.30.50.53 | s9-t24-sut1
224 10.30.50.54 | s10-t24-tg1
225 10.30.50.55 | s14-t32-sut1
226 10.30.50.56 | s15-t32-sut2
227 10.30.50.57 | s16-t32-tg1
228 10.30.50.58 | s25-t25-sut1
229 10.30.50.59 | s26-t25-tg1
230 10.30.50.69 | s27-t13-sut
231 10.30.50.255 | Broadcast
233 ### Management VLAN IP Addresses
236 ------------------------- | -------
239 10.30.51.2 | LF Reserved
240 10.30.51.3 | LF Reserved
241 10.30.51.4 | LF Reserved
242 10.30.51.5 | LF Reserved
243 10.30.51.6 | LF Reserved
244 10.30.51.7 | LF Reserved
245 10.30.51.8 | LF Reserved
246 10.30.51.9 | s22-t35-sut1 (netgate-1)
247 10.30.51.10 | s23-t35-sut2 (netgate-2)
248 10.30.51.11 | s24-t35-sut3 (netgate-3)
249 10.30.51.12 | softiron-1
250 10.30.51.13 | softiron-2
251 10.30.51.14 | softiron-3
252 10.30.51.15 | LF Reserved
254 10.30.51.17 | t1-sut1
255 10.30.51.18 | t1-sut2
257 10.30.51.21 | t2-sut1
258 10.30.51.22 | t2-sut2
260 10.30.51.25 | t3-sut1
261 10.30.51.26 | t3-sut-2
262 10.30.51.28 | t4-sut1
263 10.30.51.29 | t4-sut2
264 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
265 10.30.51.30 | t4-sut3
266 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
267 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
268 10.30.51.36 | s17-t33-sut1
269 10.30.51.37 | s18-t33-sut2
270 10.30.51.41 | s20-t34-sut1
271 10.30.51.42 | s21-t34-sut2
272 10.30.51.44 | s3-t21-sut1
273 10.30.51.45 | s4-t21-tg1
274 10.30.51.46 | s11-t31-sut1
275 10.30.51.47 | s12-t31-sut2
276 10.30.51.48 | s13-t31-tg1
277 10.30.51.49 | s19-t33t34-tg1
278 10.30.51.50 | s1-t11-sut1
279 10.30.51.51 | s2-t12-sut1
280 10.30.51.52 | s5-t22-sut1
281 10.30.51.53 | s6-t22-tg1
282 10.30.51.54 | s7-t23-sut1
283 10.30.51.55 | s8-t23-tg1
284 10.30.51.56 | s9-t24-sut1
285 10.30.51.57 | s10-t24-tg1
286 10.30.51.58 | s14-t32-sut1
287 10.30.51.59 | s15-t32-sut2
288 10.30.51.60 | s16-t32-tg1
289 10.30.51.61 | s25-t25-sut1
290 10.30.51.62 | s26-t25-tg1
291 10.30.51.69 | s27-t13-sut1
292 10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED
293 10.30.51.106-10.30.51.180 | VIRL2
294 10.30.51.181-10.30.51.254 | VIRL3
295 10.30.51.255 | Broadcast
297 ## Server Type Specification
299 FD.io CSIT lab contains following server types:
301 1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
302 - Quantity: 6 servers.
303 - Physical connectivity:
304 - CIMC and host management ports.
305 - NIC ports connected in 3-node topologies.
306 - Main HW configuration:
307 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
308 - Processors: 2* E5-2699v3 2.3 GHz.
309 - RAM Memory: 16* 32GB DDR4-2133MHz.
310 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
311 - NICs configuration:
312 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
313 - PCIe Slot1: Cisco VIC 1385 2p40GE.
314 - PCIe Slot2: Intel NIC x520 2p10GE.
316 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
317 - PCIe Slot4: Intel NIC xl710 2p40GE.
318 - PCIe Slot5: Intel NIC x710 2p10GE.
319 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
320 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
321 2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
322 - Quantity: 3 servers.
323 - Physical connectivity:
324 - CIMC and host management ports.
325 - NIC ports connected in 3-node topologies.
326 - Main HW configuration:
327 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
328 - Processors: 2* E5-2699v3 2.3 GHz.
329 - RAM Memory: 16* 32GB DDR4-2133MHz.
330 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
331 - NICs configuration:
332 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
333 - PCIe Slot1: Intel NIC xl710 2p40GE.
334 - PCIe Slot2: Intel NIC x710 2p10GE.
335 - PCIe Slot3: Intel NIC x710 2p10GE.
336 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
337 - PCIe Slot4: Intel NIC xl710 2p40GE.
338 - PCIe Slot5: Intel NIC x710 2p10GE.
339 - PCIe Slot6: Intel NIC x710 2p10GE.
341 3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
342 - Quantity: 3 servers.
343 - Physical connectivity:
344 - CIMC and host management ports.
345 - no NIC ports, standalone setup.
346 - Main HW configuration:
347 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
348 - Processors: 2* E5-2699v3 2.3 GHz.
349 - RAM Memory: 16* 32GB DDR4-2133MHz.
350 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
351 - NICs configuration:
352 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
354 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
357 4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
359 - Physical connectivity:
360 - IPMI and host management ports.
361 - NIC ports connected into 2-node and 3-node topologies.
362 - Main HW configuration:
363 - Chassis: SuperMicro SYS-7049GP-TRT.
364 - Motherboard: SuperMicro X11DPG-QT.
365 - Processors: 2* Intel Platinum 8180 2.3 GHz.
366 - RAM Memory: 16* 16GB DDR4-2666MHz.
367 - Disks: 2* 1.6TB 6G SATA SSD.
368 - NICs configuration:
369 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
370 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
371 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
372 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
373 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
374 - PCIe Slot6 86:00.xx: empty.
375 - PCIe Slot8 af:00.xx: empty.
376 - PCIe Slot10 d8:00.xx: empty.
377 2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
379 - Physical connectivity:
380 - IPMI and host management ports.
381 - NIC ports connected into 2-node and 3-node topologies.
382 - Main HW configuration:
383 - Chassis: SuperMicro SYS-7049GP-TRT.
384 - Motherboard: SuperMicro X11DPG-QT.
385 - Processors: 2* Intel Platinum 8180 2.3 GHz.
386 - RAM Memory: 16* 16GB DDR4-2666MHz.
387 - Disks: 2* 1.6TB 6G SATA SSD.
388 - NICs configuration:
389 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
390 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
391 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
392 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
393 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
394 - PCIe Slot6 86:00.xx: empty.
395 - PCIe Slot8 af:00.xx: empty.
396 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
397 3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
399 - Physical connectivity:
400 - IPMI(?) and host management ports.
401 - NIC ports connected into 3-node topology.
402 - Main HW configuration:
403 - Chassis: Huawei TaiShan 2280.
404 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
405 - RAM Memory: 8* 16GB DDR4-2400MT/s
406 - Disks: 1* 4TB SATA HDD
407 - NICs configuration:
408 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
409 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
410 4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
412 - Physical connectivity:
413 - Host management ports.
414 - NIC ports connected into 2-node and 3-node topologies.
415 - Main HW configuration:
416 - Chassis: MACCHIATObin.
417 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
418 - RAM Memory: 1* 16GB DDR4
419 - Disks: 1* 128GB(?) SATA SDD
420 - NICs configuration:
421 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
422 5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
423 - Quantity: TBD based on testbed allocation.
424 - Physical connectivity:
425 - Management: serial Port (usb) for console
426 - NIC ports connected into 2-node.
427 - Main HW configuration:
428 - Chassis: Netgate XG-2758-1u
429 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
430 - RAM Memory: 16GB ECC
432 - NICs configuration:
433 - 2x 10Gb Intel 82599ES
435 6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
437 - Physical connectivity:
438 - IPMI and host management ports.
439 - NIC ports connected into 2-node and 3-node topologies.
440 - Main HW configuration:
441 - Chassis: SuperMicro SYS-7049GP-TRT.
442 - Motherboard: SuperMicro X11DPG-QT.
443 - Processors: 2* Intel Platinum 8180 2.3 GHz.
444 - RAM Memory: 16* 16GB DDR4-2666MHz.
445 - Disks: 2* 1.6TB 6G SATA SSD.
446 - NICs configuration:
447 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
448 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
449 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
450 - PCIe Slot9 5e:00.xx: empty.
451 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
452 - PCIe Slot6 86:00.xx: empty.
453 - PCIe Slot8 af:00.xx: empty.
454 - PCIe Slot10 d8:00.xx: empty.
455 7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
457 - Physical connectivity:
458 - Host management interface: 10/100/1000-BaseT.
459 - 8-port 10GE SFP+ integrated NIC.
460 - Main HW configuration:
461 - Chassis: PS10GE4NG.
462 - Motherboard: SuperMicro X11DPG-QT.
463 - Processors: Quad-Core, Intel Processor.
464 - HW accelerators: FPGA offload.
466 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
467 - Physical Interfaces: 4 * 10GE SFP+.
468 - Operating System: Native IxOS.
469 - Interface configuration:
474 8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
476 - Physical connectivity:
477 - IPMI and host management ports.
479 - Main HW configuration:
480 - Chassis: SuperMicro SYS-7049GP-TRT.
481 - Motherboard: SuperMicro X11DPG-QT.
482 - Processors: 2* Intel Platinum 8180 2.3 GHz.
483 - RAM Memory: 16* 16GB DDR4-2666MHz.
484 - Disks: 2* 1.6TB 6G SATA SSD.
485 - NICs configuration:
486 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
487 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
488 - PCIe Slot4 3b:00.xx: empty.
489 - PCIe Slot9 5e:00.xx: empty.
490 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
491 - PCIe Slot6 86:00.xx: empty.
492 - PCIe Slot8 af:00.xx: empty.
493 - PCIe Slot10 d8:00.xx: empty.
494 9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
496 - Physical connectivity:
497 - IPMI and host management ports.
498 - NIC ports connected into 1-node topologies.
499 - Main HW configuration:
500 - Chassis: Gigabyte R181-T90 1U
501 - Motheboard: MT91-FS1
502 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
503 - RAM Memory: 4* 32GB RDIMM
504 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
505 - NICs configuration:
507 - PCIe Slot1 05:00.xx: XL710-QDA2.
508 - PCIe Slot3 08:00.xx: XL710-QDA2.
510 - PCIe Slot6 85:00.xx: XL710-QDA2.
511 10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
513 - Physical connectivity:
514 - IPMI and host management ports.
516 - Main HW configuration:
517 - Chassis: SuperMicro SYS-E300-9A
518 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
519 - RAM Memory: 32GB ECC
521 - NICs configuration:
522 - 2x 10Gb Intel x553 fiber ports
523 - 2x 10Gb Intel x553 copper ports
524 - 4x 1GB Intel I350 ports
527 ### Server and Port Naming
529 Following naming convention is used within this page to specify physical
530 connectivity and wiring across defined CSIT testbeds:
533 - testbedname: testbedN.
535 - traffic-generator: tN-tgW.
536 - system-under-testX: tN-sutX.
541 - N - testbed number.
542 - tgW - server acts as traffic-generator with W index.
543 - sutX - server acts as system-under-test with X index.
544 - Y - PCIe slot number denoting a NIC card number within the host.
545 - Z - port number on the NIC card.
548 ## Testbeds Configuration
550 ### Per Testbed Server Allocation and Naming
552 #### 1-Node-Skylake (1n-skx) PROD
555 - ServerB1 [Type-B6]:
556 - testbedname: testbed11.
557 - hostname: s1-t11-sut1.
558 - IPMI IP: 10.30.50.47
559 - Host IP: 10.30.51.50
561 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
562 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
563 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
564 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
565 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
566 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
567 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
568 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
569 - ServerB2 [Type-B6]:
570 - testbedname: testbed12.
571 - hostname: s2-t12-sut1.
572 - IPMI IP: 10.30.50.48
573 - Host IP: 10.30.51.51
575 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
576 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
577 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
578 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
579 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
580 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
581 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
582 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
585 #### 1-Node-Thunderx2 (1n-tx2) WIP
588 - ServerB17 [Type-B9]:
589 - testbedname: testbed13.
590 - hostname: s27-t13-sut1.
591 - IPMI IP: 10.30.50.69
592 - Host IP: 10.30.51.69
594 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
595 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
596 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
597 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
598 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
599 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
602 #### 2-Node-Skylake (2n-skx) PROD
605 - ServerB3 [Type-B1]:
606 - testbedname: testbed21.
607 - hostname: s3-t21-sut1.
608 - IPMI IP: 10.30.50.41
609 - Host IP: 10.30.51.44
611 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
612 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
613 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
614 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
615 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
616 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
617 - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
618 - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
619 - ServerB4 [Type-B2]:
620 - testbedname: testbed21.
621 - hostname: s4-t21-tg1.
622 - IPMI IP: 10.30.50.42
623 - Host IP: 10.30.51.45
625 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
626 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
627 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
628 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
629 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
630 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
631 - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
632 - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
633 - ServerB5 [Type-B1]:
634 - testbedname: testbed22.
635 - hostname: s5-t22-sut1.
636 - IPMI IP: 10.30.50.49
637 - Host IP: 10.30.51.52
639 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
640 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
641 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
642 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
643 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
644 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
645 - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
646 - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
647 - ServerB6 [Type-B2]:
648 - testbedname: testbed22.
649 - hostname: s6-t22-tg1.
650 - IPMI IP: 10.30.50.50
651 - Host IP: 10.30.51.53
653 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
654 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
655 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
656 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
657 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
658 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
659 - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
660 - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
661 - ServerB7 [Type-B1]:
662 - testbedname: testbed23.
663 - hostname: s7-t23-sut1.
664 - IPMI IP: 10.30.50.51
665 - Host IP: 10.30.51.54
667 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
668 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
669 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
670 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
671 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
672 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
673 - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
674 - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
675 - ServerB8 [Type-B2]:
676 - testbedname: testbed23.
677 - hostname: s8-t23-tg1.
678 - IPMI IP: 10.30.50.52
679 - Host IP: 10.30.51.55
681 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
682 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
683 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
684 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
685 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
686 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
687 - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
688 - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
689 - ServerB9 [Type-B1]:
690 - testbedname: testbed24.
691 - hostname: s9-t24-sut1.
692 - IPMI IP: 10.30.50.53
693 - Host IP: 10.30.51.56
695 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
696 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
697 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
698 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
699 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
700 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
701 - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
702 - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
703 - ServerB10 [Type-B2]:
704 - testbedname: testbed24.
705 - hostname: s10-t24-tg1.
706 - IPMI IP: 10.30.50.54
707 - Host IP: 10.30.51.57
709 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
710 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
711 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
712 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
713 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
714 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
715 - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
716 - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
719 #### 2-Node-Denverton (2n-dnv) TODO
725 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
728 - ServerB25 [Type-B8]:
729 - testbedname: testbed25.
730 - hostname: s25-t25-sut1.
731 - IPMI IP: 10.30.50.58
732 - Host IP: 10.30.51.61
734 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
735 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
736 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
737 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
738 - ServerB26 [Type-B7]:
739 - testbedname: testbed25.
740 - hostname: s26-t25-tg1.
741 - IPMI IP: 10.30.50.59
742 - Host IP: 10.30.51.62
744 - s26-t25-tg1-p1 - 10GE-port1.
745 - s26-t25-tg1-p2 - 10GE-port2.
746 - s26-t25-tg1-p3 - 10GE-port3.
747 - s26-t25-tg1-p4 - 10GE-port4.
750 #### 3-Node-Haswell (3n-hsw) PROD
753 1. Server1 of Type-1:
754 - testbedname: testbed1.
756 - CIMC IP: 10.30.50.17
757 - Host IP: 10.30.51.17
759 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
760 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
761 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
762 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
763 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
764 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
765 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
766 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
767 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
768 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
769 2. Server2 of Type-1:
770 - testbedname: testbed1.
772 - CIMC IP: 10.30.50.18
773 - Host IP: 10.30.51.18
775 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
776 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
777 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
778 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
779 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
780 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
781 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
782 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
783 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
784 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
785 3. Server3 of Type-2:
786 - testbedname: testbed1.
788 - CIMC IP: 10.30.50.16
789 - Host IP: 10.30.51.16
791 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
792 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
793 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
794 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
795 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
796 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
797 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
798 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
799 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
800 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
801 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
802 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
803 4. Server4 of Type-1:
804 - testbedname: testbed2.
806 - CIMC IP: 10.30.50.21
807 - Host IP: 10.30.51.21
809 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
810 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
811 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
812 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
813 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
814 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
815 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
816 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
817 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
818 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
819 5. Server5 of Type-1:
820 - testbedname: testbed2.
822 - CIMC IP: 10.30.50.22
823 - Host IP: 10.30.51.22
825 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
826 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
827 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
828 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
829 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
830 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
831 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
832 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
833 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
834 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
835 6. Server6 of Type-2:
836 - testbedname: testbed2.
838 - CIMC IP: 10.30.50.20
839 - Host IP: 10.30.51.20
841 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
842 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
843 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
844 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
845 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
846 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
847 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
848 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
849 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
850 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
851 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
852 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
853 7. Server7 of Type-1:
854 - testbedname: testbed3.
856 - CIMC IP: 10.30.50.25
857 - Host IP: 10.30.51.25
859 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
860 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
861 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
862 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
863 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
864 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
865 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
866 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
867 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
868 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
869 8. Server8 of Type-1:
870 - testbedname: testbed3.
872 - CIMC IP: 10.30.50.26
873 - Host IP: 10.30.51.26
875 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
876 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
877 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
878 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
879 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
880 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
881 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
882 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
883 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
884 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
885 9. Server9 of Type-2:
886 - testbedname: testbed3.
888 - CIMC IP: 10.30.50.24
889 - Host IP: 10.30.51.24
891 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
892 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
893 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
894 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
895 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
896 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
897 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
898 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
899 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
900 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
901 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
902 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
905 #### 3-Node-Skylake (3n-skx) PROD
908 - ServerB11 [Type-B1]:
909 - testbedname: testbed31.
910 - hostname: s11-t31-sut1.
911 - IPMI IP: 10.30.50.43
912 - Host IP: 10.30.51.46
914 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
915 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
916 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
917 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
918 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
919 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
920 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
921 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
922 - ServerB12 [Type-B1]:
923 - testbedname: testbed31.
924 - hostname: s12-t31-sut2.
925 - IPMI IP: 10.30.50.44
926 - Host IP: 10.30.51.47
928 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
929 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
930 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
931 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
932 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
933 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
935 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
936 - ServerB13 [Type-B2]:
937 - testbedname: testbed31.
938 - hostname: s13-t31-tg1.
939 - IPMI IP: 10.30.50.45
940 - Host IP: 10.30.51.48
942 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
943 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
944 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
945 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
946 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
947 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
948 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
949 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
950 - ServerB14 [Type-B1]:
951 - testbedname: testbed32.
952 - hostname: s14-t32-sut1.
953 - IPMI IP: 10.30.50.55
954 - Host IP: 10.30.51.58
956 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
957 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
958 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
959 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
960 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
961 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
962 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
963 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
964 - ServerB15 [Type-B1]:
965 - testbedname: testbed32.
966 - hostname: s15-t32-sut2.
967 - IPMI IP: 10.30.50.56
968 - Host IP: 10.30.51.59
970 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
971 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
972 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
973 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
974 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
975 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
976 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
977 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
978 - ServerB16 [Type-B2]:
979 - testbedname: testbed32.
980 - hostname: s16-t32-tg1.
981 - IPMI IP: 10.30.50.57
982 - Host IP: 10.30.51.60
984 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
985 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
986 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
987 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
988 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
989 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
990 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
991 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
994 Note: ServerB19 (TG) is shared between testbed33 & testbed34
996 #### 3-Node-Rangeley (3n-rng) VERIFY
998 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1001 - ServerB22 [Type-B5]:
1002 - testbedname: testbed35.
1003 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1004 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1005 - Host IP: 10.30.51.9
1007 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1008 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1010 - ServerB23 [Type-B5]:
1011 - testbedname: testbed35.
1012 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1013 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1014 - Host IP: 10.30.51.10
1016 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1017 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1019 - ServerB24 [Type-B5]:
1020 - testbedname: testbed35.
1021 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1022 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1023 - Host IP: 10.30.51.11
1025 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1026 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1030 #### 3-Node-Taishan (3n-tsh) WIP
1033 - ServerB17 [Type-B3]:
1034 - testbedname: testbed33.
1035 - hostname: s17-t33-sut1.
1036 - IPMI IP: 10.30.50.36
1037 - Host IP: 10.30.51.36
1039 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1040 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1041 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1042 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1043 - ServerB18 [Type-B3]:
1044 - testbedname: testbed33.
1045 - hostname: s18-t33-sut2.
1046 - IPMI IP: 10.30.50.37
1047 - Host IP: 10.30.51.37
1049 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1050 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1051 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1052 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1053 - ServerB19 [Type-B2]:
1054 - testbednames: testbed33 and testbed34.
1055 - hostname: s19-t33t34-tg1.
1056 - IPMI IP: 10.30.50.46
1057 - Host IP: 10.30.51.49
1059 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1060 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1061 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1062 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1063 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1064 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1065 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1066 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1067 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1068 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1069 - ServerB20 [Type-B4]:
1070 - testbedname: testbed34.
1071 - hostname: s20-t34-sut1.
1073 - Host IP: 10.30.51.41
1075 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1076 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1077 - ServerB21 [Type-B4]:
1078 - testbedname: testbed34.
1079 - hostname: s21-t34-sut2.
1081 - Host IP: 10.30.51.42
1083 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1084 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1087 #### 3-Node-Mcbin (3n-mcb) TODO
1093 ### Per Testbed Wiring
1095 #### 1-Node-Skylake (1n-skx) PROD
1099 - ring1 10GE-ports x710-4p10GE:
1100 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1101 - ring2 10GE-ports x710-4p10GE:
1102 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1103 - ring3 10GE-ports x710-4p10GE:
1104 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1105 - ring4 10GE-ports x710-4p10GE:
1106 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1108 - ring1 10GE-ports x710-4p10GE:
1109 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1110 - ring2 10GE-ports x710-4p10GE:
1111 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1112 - ring3 10GE-ports x710-4p10GE:
1113 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1114 - ring4 10GE-ports x710-4p10GE:
1115 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1118 #### 1-Node-Thunderx2 (1n-tx2) WIP
1122 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1123 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1124 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1125 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1126 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1127 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1130 #### 2-Node-Skylake (2n-skx) PROD
1134 - ring1 10GE-ports x710-4p10GE on SUT:
1135 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1136 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1137 - ring2 10GE-ports x710-4p10GE on SUT:
1138 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1139 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1140 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1141 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1142 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1143 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1144 - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
1145 - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
1146 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1147 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1148 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1150 - ring1 10GE-ports x710-4p10GE on SUT:
1151 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1152 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1153 - ring2 10GE-ports x710-4p10GE on SUT:
1154 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1155 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1156 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1157 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1158 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1159 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1160 - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
1161 - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
1162 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1163 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1164 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1166 - ring1 10GE-ports x710-4p10GE on SUT:
1167 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1168 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1169 - ring2 10GE-ports x710-4p10GE on SUT:
1170 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1171 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1172 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1173 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1174 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1175 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1176 - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
1177 - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
1178 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1179 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1180 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1182 - ring1 10GE-ports x710-4p10GE on SUT:
1183 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1184 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1185 - ring2 10GE-ports x710-4p10GE on SUT:
1186 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1187 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1188 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1189 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1190 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1191 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1192 - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
1193 - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
1194 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1195 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1196 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1199 #### 2-Node-Denverton (2n-dnv) TODO
1205 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
1209 - link1 10GE-port x710-4p10GE on SUT:
1210 - t25-tg1-p1 to t25-sut1-c2/p1.
1211 - link2 10GE-port x710-4p10GE on SUT:
1212 - t25-tg1-p2 to t25-sut1-c2/p2.
1213 - link3 10GE-port x710-4p10GE on SUT:
1214 - t25-tg1-p3 to t25-sut1-c2/p3.
1215 - link4 10GE-port x710-4p10GE on SUT:
1216 - t25-tg1-p4 to t25-sut1-c2/p4.
1219 #### 3-Node-Haswell (3n-hsw) PROD
1223 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1224 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1225 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1226 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1227 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1228 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1229 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1230 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1231 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1232 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1233 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1234 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1235 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1236 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1237 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1238 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1239 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1240 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1241 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1242 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1243 - TG loopback ports Intel NIC x710 2p10GE
1244 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1247 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1248 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1249 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1250 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1251 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1252 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1253 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1254 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1255 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1256 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1257 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1258 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1259 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1260 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1261 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1262 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1263 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1264 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1265 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1266 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1267 - TG loopback ports Intel NIC x710 2p10GE
1268 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1271 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1272 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1273 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1274 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1275 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1276 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1277 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1278 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1279 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1280 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1281 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1282 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1283 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1284 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1285 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1286 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1287 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1288 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1289 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1290 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1291 - TG loopback ports Intel NIC x710 2p10GE
1292 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1295 #### 3-Node-Skylake (3n-skx) PROD
1299 - ring1 10GE-ports x710-4p10GE on SUTs:
1300 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1301 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1302 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1303 - ring2 10GE-ports x710-4p10GE on SUT:
1304 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1305 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1306 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1307 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1308 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1309 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1310 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1311 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1312 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1313 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1314 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1315 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1316 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1317 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1319 - ring1 10GE-ports x710-4p10GE on SUTs:
1320 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1321 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1322 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1323 - ring2 10GE-ports x710-4p10GE on SUT:
1324 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1325 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1326 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1327 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1328 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1329 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1330 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1331 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1332 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1333 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1334 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1335 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1336 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1337 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1340 #### 3-Node-Rangeley (3n-rng) TODO
1346 #### 3-Node-Taishan (3n-tsh) WIP
1350 - ring1 10GE-ports x520-2p10GE on SUTs:
1351 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1352 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1353 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1354 - ring2 25GE-ports cx4-2p25GE on SUTs:
1355 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1356 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1357 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1360 #### 3-Node-Mcbin (3n-mcb) WIP
1364 - ring1 10GE-ports Marvell on SUTs:
1365 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1366 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1367 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1375 1. Ixia PerfectStorm One Appliance
1377 - Chassis: PS10GE4NG.
1378 - Motherboard: SuperMicro X11DPG-QT.
1379 - Processors: Quad-Core, Intel Processor.
1380 - HW accelerators: FPGA offload.
1382 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1383 - Physical Interfaces: 4 * 10GE SFP+.
1384 - Operating System: Native IxOS.
1390 1. Arm Cortex A-72 servers
1392 - Chassis: Marvell ThunderX2
1393 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1394 - RAM Memory: 4* 32GB RDIMM
1395 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1396 - 2 * Huawei TaiShan 2280.
1397 - Chassis: Huawei TaiShan 2280.
1398 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1399 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1400 - Disks: 1* 4TB SATA HDD.
1402 - Chassis: MACCHIATObin.
1403 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1404 - RAM Memory: 1* 16GB DDR4.
1405 - Disks: 1* 128GB(?) SATA SDD.
1408 ### Xeon and Atom Servers
1411 1. Intel Xeon servers:
1412 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1413 - Chassis: SuperMicro SYS-7049GP-TRT.
1414 - Motherboard: SuperMicro X11DPG-QT.
1415 - Processors: 2* Intel Platinum 8180 2.3 GHz.
1416 - RAM Memory: 16* 16GB DDR4-2666MHz.
1417 - Disks: 2* 1.6TB 6G SATA SSD.
1418 2. Intel Atom servers with Rangely processors.
1419 - 3 * Netgate XG-2758-1u
1420 - Chassis: Netgate XG-2758-1u
1421 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1422 - RAM Memory: 16GB ECC
1426 ### Network Interface Cards
1430 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1431 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1432 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1434 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1436 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1438 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1441 ### Pluggables and Cables
1447 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1448 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1454 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1465 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable