1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
74 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
75 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
76 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
77 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
78 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
79 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
80 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
84 13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
85 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
86 Totals: 22 35 18 12 19 1 2 3 1 2 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
156 ### 3-Node-MACCHIATObin Arm Marvell
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
163 ### 3-Node-Rangeley Atom Testbeds
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
174 For management purposes, each server must have following two ports
175 connected to the management network:
179 - IPMI - Intelligent Platform Management Interface.
180 - Required for access to embedded server management with WebUI, CLI,
181 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183 - hostOS management port for general system management.
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
193 - Subnet: 10.30.50.0/24
194 - Gateway: 10.30.50.1
195 - Broadcast: 10.30.50.255
196 - DNS1: 199.204.44.24
197 - DNS2: 199.204.47.54
199 - Subnet: 10.30.51.0/24
200 - Gateway: 10.30.51.1
201 - Broadcast: 10.30.51.255
202 - DNS1: 199.204.44.24
203 - DNS2: 199.204.47.54
206 To access these hosts, VPN connection is required.
208 ### LOM (IPMI) VLAN IP Addresses
211 ------------ | -------
214 10.30.50.2 | LF Reserved
215 10.30.50.3 | LF Reserved
216 10.30.50.4 | LF Reserved
217 10.30.50.5 | LF Reserved
218 10.30.50.6 | LF Reserved
219 10.30.50.7 | LF Reserved
220 10.30.50.8 | LF Reserved
221 10.30.50.9 | LF Reserved
222 10.30.50.10 | LF Reserved
223 10.30.50.11 | LF Reserved
224 10.30.50.12 | LF Reserved
225 10.30.50.13 | LF Reserved
226 10.30.50.14 | LF Reserved
227 10.30.50.15 | LF Reserved
229 10.30.50.17 | t1-sut1
230 10.30.50.18 | t1-sut2
232 10.30.50.21 | t2-sut1
233 10.30.50.22 | t2-sut2
235 10.30.50.25 | t3-sut1
236 10.30.50.26 | t3-sut-2
237 10.30.50.28 | s41-nomad
238 10.30.50.29 | s39-nomad
239 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30 | s40-nomad
241 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.32 | s42-nomad (formerly nomad1)
244 10.30.50.33 | s43-nomad (formerly nomad2)
245 10.30.50.34 | s44-nomad (formerly nomad3)
246 10.30.50.35 | s45-nomad (formerly nomad4)
247 10.30.50.36 | s17-t33-sut1
248 10.30.50.37 | s18-t33-sut2
249 10.30.50.38 | fdio-marvell-dev
250 10.30.50.39 | s53-nomad
251 10.30.50.40 | s54-nomad
252 10.30.50.41 | s3-t21-sut1
253 10.30.50.42 | s4-t21-tg1
254 10.30.50.43 | s11-t31-sut1
255 10.30.50.44 | s12-t31-sut2
256 10.30.50.45 | s13-t31-tg1
257 10.30.50.46 | s19-t33t34-tg1
258 10.30.50.47 | s1-t11-sut1
259 10.30.50.48 | s2-t12-sut1
260 10.30.50.49 | s5-t22-sut1
261 10.30.50.50 | s6-t22-tg1
262 10.30.50.51 | s7-t23-sut1
263 10.30.50.52 | s8-t23-tg1
264 10.30.50.53 | s9-t24-sut1
265 10.30.50.54 | s10-t24-tg1
266 10.30.50.55 | s14-t32-sut1
267 10.30.50.56 | s15-t32-sut2
268 10.30.50.57 | s16-t32-tg1
269 10.30.50.58 | s25-t25-sut1
270 10.30.50.59 | s26-t25-tg1
271 10.30.50.65 | s52-nomad
272 10.30.50.66 | s51-nomad (out of order)
273 10.30.50.67 | s49-nomad
274 10.30.50.68 | s50-nomad (out of order)
275 10.30.50.69 | s27-t13-sut
276 10.30.50.255 | Broadcast
281 10.30.55.10 | s28-t26t35-tg1
282 10.30.55.11 | s29-t26-sut1
283 10.30.55.12 | s30-t35-sut1
284 10.30.55.13 | s31-t35-sut2
285 10.30.55.14 | s46-nomad (formerly server-type-c4-1)
286 10.30.55.15 | s47-nomad (formerly server-type-c4-2)
287 10.30.55.16 | s48-nomad (formerly server-type-c4-3)
288 10.30.55.17 | s32-t14-sut1
289 10.30.55.18 | s33-t27-sut1
290 10.30.55.19 | s34-t27-tg1
291 10.30.55.20 | s35-t28-sut1
292 10.30.55.21 | s36-t28-tg1
293 10.30.55.22 | s37-t29-sut1
294 10.30.55.23 | s38-t29-tg1
295 10.30.55.255 | Broadcast
297 ### Management VLAN IP Addresses
300 ------------------------- | -------
303 10.30.51.2 | LF Reserved
304 10.30.51.3 | LF Reserved
305 10.30.51.4 | LF Reserved
306 10.30.51.5 | LF Reserved
307 10.30.51.6 | LF Reserved
308 10.30.51.7 | LF Reserved
309 10.30.51.8 | LF Reserved
310 10.30.51.9 | s22-t35-sut1 (netgate-1)
311 10.30.51.10 | s23-t35-sut2 (netgate-2)
312 10.30.51.11 | s24-t35-sut3 (netgate-3)
313 10.30.51.12 | softiron-1
314 10.30.51.13 | softiron-2
315 10.30.51.14 | softiron-3
316 10.30.51.15 | LF Reserved
318 10.30.51.17 | t1-sut1
319 10.30.51.18 | t1-sut2
321 10.30.51.21 | t2-sut1
322 10.30.51.22 | t2-sut2
324 10.30.51.25 | t3-sut1
325 10.30.51.26 | t3-sut-2
326 10.30.51.28 | s41-nomad
327 10.30.51.29 | s39-nomad
328 10.30.51.30 | s40-nomad
329 10.30.51.32 | s42-nomad (formerly nomad1)
330 10.30.51.33 | s43-nomad (formerly nomad2)
331 10.30.51.34 | s44-nomad (formerly nomad3)
332 10.30.51.35 | s45-nomad (formerly nomad4)
333 10.30.51.36 | s17-t33-sut1
334 10.30.51.37 | s18-t33-sut2
335 10.30.51.38 | fdio-marvell-dev
336 10.30.51.39 | s53-nomad
337 10.30.51.40 | s54-nomad
338 10.30.51.41 | s20-t34-sut1
339 10.30.51.42 | s21-t34-sut2
340 10.30.51.44 | s3-t21-sut1
341 10.30.51.45 | s4-t21-tg1
342 10.30.51.46 | s11-t31-sut1
343 10.30.51.47 | s12-t31-sut2
344 10.30.51.48 | s13-t31-tg1
345 10.30.51.49 | s19-t33t34-tg1
346 10.30.51.50 | s1-t11-sut1
347 10.30.51.51 | s2-t12-sut1
348 10.30.51.52 | s5-t22-sut1
349 10.30.51.53 | s6-t22-tg1
350 10.30.51.54 | s7-t23-sut1
351 10.30.51.55 | s8-t23-tg1
352 10.30.51.56 | s9-t24-sut1
353 10.30.51.57 | s10-t24-tg1
354 10.30.51.58 | s14-t32-sut1
355 10.30.51.59 | s15-t32-sut2
356 10.30.51.60 | s16-t32-tg1
357 10.30.51.61 | s25-t25-sut1
358 10.30.51.62 | s26-t25-tg1
359 10.30.51.65 | s52-nomad
360 10.30.51.66 | s51-nomad (out of order)
361 10.30.51.67 | s49-nomad
362 10.30.51.68 | s50-nomad (out of order)
363 10.30.51.69 | s27-t13-sut1
364 10.30.51.70-10.30.51.105 | FREE
365 10.30.51.106-10.30.51.180 | FREE
366 10.30.51.181-10.30.51.254 | FREE
367 10.30.51.255 | Broadcast
370 10.32.8.10 | s28-t26t35-tg1
371 10.32.8.11 | s29-t26-sut1
372 10.32.8.12 | s30-t35-sut1
373 10.32.8.13 | s31-t35-sut2
374 10.32.8.14 | s46-nomad (formerly server-type-c4-1)
375 10.32.8.15 | s47-nomad (formerly server-type-c4-2)
376 10.32.8.16 | s48-nomad (formerly server-type-c4-3)
377 10.32.8.17 | s32-t14-sut1
378 10.32.8.18 | s33-t27-sut1
379 10.32.8.19 | s34-t27-tg1
380 10.32.8.20 | s35-t28-sut1
381 10.32.8.21 | s36-t28-tg1
382 10.32.8.22 | s37-t29-sut1
383 10.32.8.23 | s38-t29-tg1
384 10.32.8.255 | Broadcast
386 ## Server Specifications
390 FD.io CSIT lab contains following server types:
392 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
393 - Quantity: 6 servers.
394 - Physical connectivity:
395 - CIMC and host management ports.
396 - NIC ports connected in 3-node topologies.
397 - Main HW configuration:
398 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
399 - Processors: 2* E5-2699v3 2.3 GHz.
400 - RAM Memory: 16* 32GB DDR4-2133MHz.
401 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
402 - NICs configuration:
403 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
404 - PCIe Slot1: Cisco VIC 1385 2p40GE.
405 - PCIe Slot2: Intel NIC x520 2p10GE.
407 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
408 - PCIe Slot4: Intel NIC xl710 2p40GE.
409 - PCIe Slot5: Intel NIC x710 2p10GE.
410 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
411 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
412 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
413 - Quantity: 3 servers.
414 - Physical connectivity:
415 - CIMC and host management ports.
416 - NIC ports connected in 3-node topologies.
417 - Main HW configuration:
418 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419 - Processors: 2* E5-2699v3 2.3 GHz.
420 - RAM Memory: 16* 32GB DDR4-2133MHz.
421 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
422 - NICs configuration:
423 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
424 - PCIe Slot1: Intel NIC xl710 2p40GE.
425 - PCIe Slot2: Intel NIC x710 2p10GE.
426 - PCIe Slot3: Intel NIC x710 2p10GE.
427 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
428 - PCIe Slot4: Intel NIC xl710 2p40GE.
429 - PCIe Slot5: Intel NIC x710 2p10GE.
430 - PCIe Slot6: Intel NIC x710 2p10GE.
432 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
433 - Quantity: 3 servers.
434 - Physical connectivity:
435 - CIMC and host management ports.
436 - no NIC ports, standalone setup.
437 - Main HW configuration:
438 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
439 - Processors: 2* E5-2699v3 2.3 GHz.
440 - RAM Memory: 16* 32GB DDR4-2133MHz.
441 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
442 - NICs configuration:
443 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
445 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
448 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
450 - Physical connectivity:
451 - IPMI and host management ports.
452 - NIC ports connected into 2-node and 3-node topologies.
453 - Main HW configuration:
454 - Chassis: SuperMicro SYS-7049GP-TRT.
455 - Motherboard: SuperMicro X11DPG-QT.
456 - Processors: 2* Intel Platinum 8180 2.5 GHz.
457 - RAM Memory: 16* 16GB DDR4-2666MHz.
458 - Disks: 2* 1.6TB 6G SATA SSD.
459 - NICs configuration:
460 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
461 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
462 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
463 - PCIe Slot9 5e:00.xx: empty.
464 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
465 - PCIe Slot6 86:00.xx: empty.
466 - PCIe Slot8 af:00.xx: empty.
467 - PCIe Slot10 d8:00.xx: empty.
468 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
470 - Physical connectivity:
471 - IPMI and host management ports.
472 - NIC ports connected into 2-node and 3-node topologies.
473 - Main HW configuration:
474 - Chassis: SuperMicro SYS-7049GP-TRT.
475 - Motherboard: SuperMicro X11DPG-QT.
476 - Processors: 2* Intel Platinum 8180 2.5 GHz.
477 - RAM Memory: 16* 16GB DDR4-2666MHz.
478 - Disks: 2* 1.6TB 6G SATA SSD.
479 - NICs configuration:
480 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
481 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
482 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
483 - PCIe Slot9 5e:00.xx: empty.
484 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
485 - PCIe Slot6 86:00.xx: empty.
486 - PCIe Slot8 af:00.xx: empty.
487 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
488 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
490 - Physical connectivity:
491 - IPMI(?) and host management ports.
492 - NIC ports connected into 3-node topology.
493 - Main HW configuration:
494 - Chassis: Huawei TaiShan 2280.
495 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
496 - RAM Memory: 8* 16GB DDR4-2400MT/s
497 - Disks: 1* 4TB SATA HDD
498 - NICs configuration:
499 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
500 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
501 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
503 - Physical connectivity:
504 - Host management ports.
505 - NIC ports connected into 2-node and 3-node topologies.
506 - Main HW configuration:
507 - Chassis: MACCHIATObin.
508 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
509 - RAM Memory: 1* 16GB DDR4
510 - Disks: 1* 128GB(?) SATA SDD
511 - NICs configuration:
512 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
513 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
514 - Quantity: TBD based on testbed allocation.
515 - Physical connectivity:
516 - Management: serial Port (usb) for console
517 - NIC ports connected into 2-node.
518 - Main HW configuration:
519 - Chassis: Netgate XG-2758-1u
520 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
521 - RAM Memory: 16GB ECC
523 - NICs configuration:
524 - 2x 10Gb Intel 82599ES
526 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
528 - Physical connectivity:
529 - IPMI and host management ports.
530 - NIC ports connected into 2-node and 3-node topologies.
531 - Main HW configuration:
532 - Chassis: SuperMicro SYS-7049GP-TRT.
533 - Motherboard: SuperMicro X11DPG-QT.
534 - Processors: 2* Intel Platinum 8180 2.5 GHz.
535 - RAM Memory: 16* 16GB DDR4-2666MHz.
536 - Disks: 2* 1.6TB 6G SATA SSD.
537 - NICs configuration:
538 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
539 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
540 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
541 - PCIe Slot9 5e:00.xx: empty.
542 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
543 - PCIe Slot6 86:00.xx: empty.
544 - PCIe Slot8 af:00.xx: empty.
545 - PCIe Slot10 d8:00.xx: empty.
546 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
548 - Physical connectivity:
549 - Host management interface: 10/100/1000-BaseT.
550 - 8-port 10GE SFP+ integrated NIC.
551 - Main HW configuration:
552 - Chassis: PS10GE4NG.
553 - Motherboard: SuperMicro X11DPG-QT.
554 - Processors: Quad-Core, Intel Processor.
555 - HW accelerators: FPGA offload.
557 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
558 - Physical Interfaces: 4 * 10GE SFP+.
559 - Operating System: Native IxOS.
560 - Interface configuration:
565 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
567 - Physical connectivity:
568 - IPMI and host management ports.
570 - Main HW configuration:
571 - Chassis: SuperMicro SYS-7049GP-TRT.
572 - Motherboard: SuperMicro X11DPG-QT.
573 - Processors: 2* Intel Platinum 8180 2.5 GHz.
574 - RAM Memory: 16* 16GB DDR4-2666MHz.
575 - Disks: 2* 1.6TB 6G SATA SSD.
576 - NICs configuration:
577 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
578 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
579 - PCIe Slot4 3b:00.xx: empty.
580 - PCIe Slot9 5e:00.xx: empty.
581 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
582 - PCIe Slot6 86:00.xx: empty.
583 - PCIe Slot8 af:00.xx: empty.
584 - PCIe Slot10 d8:00.xx: empty.
585 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
587 - Physical connectivity:
588 - IPMI and host management ports.
589 - NIC ports connected into 1-node topologies.
590 - Main HW configuration:
591 - Chassis: Gigabyte R181-T90 1U
592 - Motheboard: MT91-FS1
593 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
594 - RAM Memory: 4* 32GB RDIMM
595 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
596 - NICs configuration:
598 - PCIe Slot1 05:00.xx: XL710-QDA2.
599 - PCIe Slot3 08:00.xx: XL710-QDA2.
601 - PCIe Slot6 85:00.xx: XL710-QDA2.
602 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
604 - Physical connectivity:
605 - IPMI and host management ports.
607 - Main HW configuration:
608 - Chassis: SuperMicro SYS-E300-9A
609 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
610 - RAM Memory: 32GB ECC
612 - NICs configuration:
613 - 2x 10Gb Intel x553 fiber ports
614 - 2x 10Gb Intel x553 copper ports
615 - 4x 1GB Intel I350 ports
617 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
619 - Physical connectivity:
620 - IPMI and host management ports.
621 - NIC ports connected into 1-node testbed topologies.
622 - Main HW configuration:
623 - Chassis: SuperMicro SYS-7049GP-TRT.
624 - Motherboard: SuperMicro X11DPG-QT.
625 - Processors: 2* Intel Platinum 8280 2.7 GHz.
626 - RAM Memory: 12* 16GB DDR4-2933.
627 - Disks: 2* 1.92TB SATA SSD.
628 - NICs configuration:
629 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
630 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
631 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
632 - PCIe Slot9 5e:00.xx: empty.
633 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
634 - PCIe Slot6 86:00.xx: empty.
635 - PCIe Slot8 af:00.xx: empty.
636 - PCIe Slot10 d8:00.xx: empty.
638 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
640 - Physical connectivity:
641 - IPMI and host management ports.
642 - NIC ports connected into 2-node testbed topologies.
643 - Main HW configuration:
644 - Chassis: SuperMicro SYS-7049GP-TRT.
645 - Motherboard: SuperMicro X11DPG-QT.
646 - Processors: 2* Intel Gold 6252N 2.3 GHz.
647 - RAM Memory: 12* 16GB DDR4-2933.
648 - Disks: 2* 1.92TB SATA SSD.
649 - NICs configuration:
650 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
651 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
652 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
653 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
654 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
655 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
656 - PCIe Slot6 86:00.xx: empty.
657 - PCIe Slot8 af:00.xx: empty.
658 - PCIe Slot10 d8:00.xx: empty.
659 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
661 - Physical connectivity:
662 - IPMI and host management ports.
663 - NIC ports connected into 2-node testbed topologies.
664 - Main HW configuration:
665 - Chassis: SuperMicro SYS-7049GP-TRT.
666 - Motherboard: SuperMicro X11DPG-QT.
667 - Processors: 2* Intel Platinum 8280 2.7 GHz.
668 - RAM Memory: 12* 16GB DDR4-2933.
669 - Disks: 2* 1.92TB SATA SSD.
670 - NICs configuration:
671 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
672 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
673 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
674 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
675 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
676 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
677 - PCIe Slot6 86:00.xx: empty.
678 - PCIe Slot8 af:00.xx: empty.
679 - PCIe Slot10 d8:00.xx: empty.
681 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
683 - Physical connectivity:
684 - CIMC and host management ports.
685 - no NIC ports, standalone setup.
686 - Main HW configuration:
687 - Chassis: SuperMicro 1029P-WTRT.
688 - Motherboard: SuperMicro X11DDW-NT.
689 - Processors: 2* Intel Platinum 8280 2.7 GHz.
690 - RAM Memory: 12* 16GB DDR4-2933.
691 - Disks: 4* 1.92TB SATA SSD.
692 - NICs configuration:
699 ### Naming Convention
701 Following naming convention is used within this page to specify physical
702 connectivity and wiring across defined CSIT testbeds:
705 - testbedname: testbedN.
707 - traffic-generator: tN-tgW.
708 - system-under-testX: tN-sutX.
713 - N - testbed number.
714 - tgW - server acts as traffic-generator with W index.
715 - sutX - server acts as system-under-test with X index.
716 - Y - PCIe slot number denoting a NIC card number within the host.
717 - Z - port number on the NIC card.
720 ## Testbeds Configuration
722 ### Per Testbed Server Allocation and Naming
724 #### 1-Node-Skylake Servers (1n-skx) PROD
727 - SUT [Server-Type-B6]:
728 - testbedname: testbed11.
729 - hostname: s1-t11-sut1.
730 - IPMI IP: 10.30.50.47
731 - Host IP: 10.30.51.50
733 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
734 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
735 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
736 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
737 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
738 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
739 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
740 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
741 - SUT [Server-Type-B6]:
742 - testbedname: testbed12.
743 - hostname: s2-t12-sut1.
744 - IPMI IP: 10.30.50.48
745 - Host IP: 10.30.51.51
747 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
748 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
749 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
750 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
751 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
752 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
753 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
754 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
757 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
760 - SUT [Server-Type-B9]:
761 - testbedname: testbed13.
762 - hostname: s27-t13-sut1.
763 - IPMI IP: 10.30.50.69
764 - Host IP: 10.30.51.69
766 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
767 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
768 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
769 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
770 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
771 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
774 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
777 - SUT [Server-Type-C1]:
778 - testbedname: testbed11.
779 - hostname: s32-t14-sut1.
780 - IPMI IP: 10.30.55.17
781 - Host IP: 10.32.8.17
783 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
784 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
785 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
786 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
787 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
788 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
789 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
790 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
793 #### 2-Node-Skylake Servers (2n-skx) PROD
796 - SUT [Server-Type-B1]:
797 - testbedname: testbed21.
798 - hostname: s3-t21-sut1.
799 - IPMI IP: 10.30.50.41
800 - Host IP: 10.30.51.44
802 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
803 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
804 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
805 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
806 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
807 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
808 - TG [Server-Type-B2]:
809 - testbedname: testbed21.
810 - hostname: s4-t21-tg1.
811 - IPMI IP: 10.30.50.42
812 - Host IP: 10.30.51.45
814 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
815 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
816 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
817 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
818 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
819 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
820 - SUT [Server-Type-B1]:
821 - testbedname: testbed22.
822 - hostname: s5-t22-sut1.
823 - IPMI IP: 10.30.50.49
824 - Host IP: 10.30.51.52
826 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
827 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
828 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
829 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
830 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
831 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
832 - TG [Server-Type-B2]:
833 - testbedname: testbed22.
834 - hostname: s6-t22-tg1.
835 - IPMI IP: 10.30.50.50
836 - Host IP: 10.30.51.53
838 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
839 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
840 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
841 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
842 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
843 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
844 - SUT [Server-Type-B1]:
845 - testbedname: testbed23.
846 - hostname: s7-t23-sut1.
847 - IPMI IP: 10.30.50.51
848 - Host IP: 10.30.51.54
850 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
851 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
852 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
853 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
854 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
855 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
856 - TG [Server-Type-B2]:
857 - testbedname: testbed23.
858 - hostname: s8-t23-tg1.
859 - IPMI IP: 10.30.50.52
860 - Host IP: 10.30.51.55
862 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
863 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
864 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
865 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
866 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
867 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
868 - SUT [Server-Type-B1]:
869 - testbedname: testbed24.
870 - hostname: s9-t24-sut1.
871 - IPMI IP: 10.30.50.53
872 - Host IP: 10.30.51.56
874 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
875 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
876 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
877 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
878 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
879 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
880 - TG [Server-Type-B2]:
881 - testbedname: testbed24.
882 - hostname: s10-t24-tg1.
883 - IPMI IP: 10.30.50.54
884 - Host IP: 10.30.51.57
886 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
887 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
888 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
889 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
890 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
891 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
894 #### 2-Node-Denverton Servers (2n-dnv) WIP
896 Note: ServerB28 (TG) is shared between testbed26 & testbed35
899 - TG [Server-Type-B2]:
900 - testbednames: testbed26 and testbed35.
901 - hostname: s28-t26t35-tg1.
902 - IPMI IP: 10.30.55.10
903 - Host IP: 10.32.8.10
905 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
906 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
907 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
908 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
909 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
910 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
911 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
912 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
913 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
914 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
915 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
916 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
917 - SUT [Server-Type-B10]:
918 - testbednames: testbed26.
919 - hostname: s29-t26-sut1.
920 - IPMI IP: 10.30.55.11
921 - Host IP: 10.32.8.11
923 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
924 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
925 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
926 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
929 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
932 - SUT [Server-Type-B8]:
933 - testbedname: testbed25.
934 - hostname: s25-t25-sut1.
935 - IPMI IP: 10.30.50.58
936 - Host IP: 10.30.51.61
938 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
939 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
940 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
941 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
942 - TG [Server-Type-B7]:
943 - testbedname: testbed25.
944 - hostname: s26-t25-tg1.
945 - IPMI IP: 10.30.50.59
946 - Host IP: 10.30.51.62
948 - s26-t25-tg1-p1 - 10GE-port1.
949 - s26-t25-tg1-p2 - 10GE-port2.
950 - s26-t25-tg1-p3 - 10GE-port3.
951 - s26-t25-tg1-p4 - 10GE-port4.
954 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
957 - SUT [Server-Type-C2]:
958 - testbedname: testbed27.
959 - hostname: s33-t27-sut1.
960 - IPMI IP: 10.30.55.18
961 - Host IP: 10.32.8.18
963 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
964 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
965 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
966 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
967 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
968 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
969 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
970 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
971 - TG [Server-Type-C3]:
972 - testbedname: testbed27.
973 - hostname: s34-t27-tg1.
974 - IPMI IP: 10.30.55.19
975 - Host IP: 10.32.8.19
977 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
978 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
979 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
980 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
981 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
982 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
983 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
984 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
985 - SUT [Server-Type-C2]:
986 - testbedname: testbed28.
987 - hostname: s35-t28-sut1.
988 - IPMI IP: 10.30.55.20
989 - Host IP: 10.32.8.20
991 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
992 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
993 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
994 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
995 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
996 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
997 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
998 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
999 - TG [Server-Type-C3]:
1000 - testbedname: testbed28.
1001 - hostname: s36-t28-tg1.
1002 - IPMI IP: 10.30.55.21
1003 - Host IP: 10.32.8.21
1005 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1006 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1007 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1008 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1009 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1010 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1011 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1012 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1013 - SUT [Server-Type-C2]:
1014 - testbedname: testbed29.
1015 - hostname: s37-t29-sut1.
1016 - IPMI IP: 10.30.55.22
1017 - Host IP: 10.32.8.22
1019 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1020 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1021 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1022 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1023 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1024 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1025 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1026 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1027 - TG [Server-Type-C3]:
1028 - testbedname: testbed29.
1029 - hostname: s38-t29-tg1.
1030 - IPMI IP: 10.30.55.23
1031 - Host IP: 10.32.8.23
1033 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1034 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1035 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1036 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1037 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1038 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1039 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1040 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1043 #### 3-Node-Haswell Servers (3n-hsw) PROD
1046 1. SUT [Server-Type-A1]:
1047 - testbedname: testbed1.
1048 - hostname: t1-sut1.
1049 - CIMC IP: 10.30.50.17
1050 - Host IP: 10.30.51.17
1052 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1053 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1054 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1055 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1056 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1057 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1058 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1059 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1060 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1061 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1062 2. SUT [Server-Type-A1]:
1063 - testbedname: testbed1.
1064 - hostname: t1-sut2.
1065 - CIMC IP: 10.30.50.18
1066 - Host IP: 10.30.51.18
1068 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1069 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1070 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1071 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1072 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1073 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1074 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1075 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1076 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1077 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1078 3. TG [Server-Type-A2]:
1079 - testbedname: testbed1.
1081 - CIMC IP: 10.30.50.16
1082 - Host IP: 10.30.51.16
1084 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1085 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1086 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1087 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1088 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1089 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1090 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1091 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1092 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1093 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1094 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1095 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1096 4. SUT [Server-Type-A1]:
1097 - testbedname: testbed2.
1098 - hostname: t2-sut1.
1099 - CIMC IP: 10.30.50.21
1100 - Host IP: 10.30.51.21
1102 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1103 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1104 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1105 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1106 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1107 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1108 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1109 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1110 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1111 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1112 5. SUT [Server-Type-A1]:
1113 - testbedname: testbed2.
1114 - hostname: t2-sut2.
1115 - CIMC IP: 10.30.50.22
1116 - Host IP: 10.30.51.22
1118 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1119 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1120 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1121 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1122 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1123 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1124 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1125 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1126 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1127 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1128 6. TG [Server-Type-A2]:
1129 - testbedname: testbed2.
1131 - CIMC IP: 10.30.50.20
1132 - Host IP: 10.30.51.20
1134 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1135 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1136 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1137 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1138 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1139 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1140 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1141 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1142 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1143 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1144 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1145 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1146 7. SUT [Server-Type-A1]:
1147 - testbedname: testbed3.
1148 - hostname: t3-sut1.
1149 - CIMC IP: 10.30.50.25
1150 - Host IP: 10.30.51.25
1152 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1153 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1154 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1155 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1156 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1157 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1158 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1159 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1160 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1161 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1162 8. SUT [Server-Type-A1]:
1163 - testbedname: testbed3.
1164 - hostname: t3-sut2.
1165 - CIMC IP: 10.30.50.26
1166 - Host IP: 10.30.51.26
1168 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1169 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1170 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1171 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1172 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1173 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1174 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1175 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1176 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1177 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1178 9. TG [Server-Type-A2]:
1179 - testbedname: testbed3.
1181 - CIMC IP: 10.30.50.24
1182 - Host IP: 10.30.51.24
1184 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1185 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1186 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1187 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1188 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1189 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1190 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1191 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1192 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1193 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1194 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1195 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1198 #### 3-Node-Skylake Servers (3n-skx) PROD
1201 - ServerB11 [Server-Type-B1]:
1202 - testbedname: testbed31.
1203 - hostname: s11-t31-sut1.
1204 - IPMI IP: 10.30.50.43
1205 - Host IP: 10.30.51.46
1207 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1208 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1209 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1210 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1211 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1212 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1213 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1214 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1215 - ServerB12 [Server-Type-B1]:
1216 - testbedname: testbed31.
1217 - hostname: s12-t31-sut2.
1218 - IPMI IP: 10.30.50.44
1219 - Host IP: 10.30.51.47
1221 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1222 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1223 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1224 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1225 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1226 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1227 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1228 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1229 - ServerB13 [Server-Type-B2]:
1230 - testbedname: testbed31.
1231 - hostname: s13-t31-tg1.
1232 - IPMI IP: 10.30.50.45
1233 - Host IP: 10.30.51.48
1235 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1236 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1237 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1238 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1239 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1240 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1241 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1242 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1243 - ServerB14 [Server-Type-B1]:
1244 - testbedname: testbed32.
1245 - hostname: s14-t32-sut1.
1246 - IPMI IP: 10.30.50.55
1247 - Host IP: 10.30.51.58
1249 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1250 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1251 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1252 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1253 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1254 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1255 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1256 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1257 - ServerB15 [Server-Type-B1]:
1258 - testbedname: testbed32.
1259 - hostname: s15-t32-sut2.
1260 - IPMI IP: 10.30.50.56
1261 - Host IP: 10.30.51.59
1263 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1264 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1265 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1266 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1267 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1268 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1269 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1270 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1271 - ServerB16 [Server-Type-B2]:
1272 - testbedname: testbed32.
1273 - hostname: s16-t32-tg1.
1274 - IPMI IP: 10.30.50.57
1275 - Host IP: 10.30.51.60
1277 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1278 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1279 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1280 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1281 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1282 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1283 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1284 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1287 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1289 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1292 - ServerB22 [Server-Type-B5]:
1293 - testbedname: testbed35.
1294 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1295 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1296 - Host IP: 10.30.51.9
1298 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1299 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1301 - ServerB23 [Server-Type-B5]:
1302 - testbedname: testbed35.
1303 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1304 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1305 - Host IP: 10.30.51.10
1307 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1308 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1310 - ServerB24 [Server-Type-B5]:
1311 - testbedname: testbed35.
1312 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1313 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1314 - Host IP: 10.30.51.11
1316 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1317 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1321 #### 3-Node-Taishan Servers (3n-tsh) WIP
1323 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1326 - ServerB17 [Server-Type-B3]:
1327 - testbedname: testbed33.
1328 - hostname: s17-t33-sut1.
1329 - IPMI IP: 10.30.50.36
1330 - Host IP: 10.30.51.36
1332 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1333 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1334 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1335 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1336 - ServerB18 [Server-Type-B3]:
1337 - testbedname: testbed33.
1338 - hostname: s18-t33-sut2.
1339 - IPMI IP: 10.30.50.37
1340 - Host IP: 10.30.51.37
1342 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1343 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1344 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1345 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1346 - ServerB19 [Server-Type-B2]:
1347 - testbednames: testbed33 and testbed34.
1348 - hostname: s19-t33t34-tg1.
1349 - IPMI IP: 10.30.50.46
1350 - Host IP: 10.30.51.49
1352 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1353 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1354 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1355 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1356 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1357 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1358 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1359 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1360 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1361 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1362 - ServerB20 [Server-Type-B4]:
1363 - testbedname: testbed34.
1364 - hostname: s20-t34-sut1.
1366 - Host IP: 10.30.51.41
1368 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1369 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1370 - ServerB21 [Server-Type-B4]:
1371 - testbedname: testbed34.
1372 - hostname: s21-t34-sut2.
1374 - Host IP: 10.30.51.42
1376 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1377 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1380 #### 3-Node-Denverton Servers (3n-dnv) WIP
1383 - ServerB30 [Server-Type-B10]:
1384 - testbednames: testbed35.
1385 - hostname: s30-t35-sut1.
1386 - IPMI IP: 10.30.55.12
1387 - Host IP: 10.32.8.12
1389 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1390 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1391 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1392 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1393 - ServerB31 [Server-Type-B10]:
1394 - testbednames: testbed35.
1395 - hostname: s31-t35-sut2.
1396 - IPMI IP: 10.30.55.13
1397 - Host IP: 10.32.8.13
1399 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1400 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1401 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1402 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1405 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1411 ### Per Testbed Wiring
1413 #### 1-Node-Skylake Wiring (1n-skx) PROD
1417 - ring1 10GE-ports x710-4p10GE:
1418 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1419 - ring2 10GE-ports x710-4p10GE:
1420 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1421 - ring3 10GE-ports x710-4p10GE:
1422 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1423 - ring4 10GE-ports x710-4p10GE:
1424 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1426 - ring1 10GE-ports x710-4p10GE:
1427 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1428 - ring2 10GE-ports x710-4p10GE:
1429 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1430 - ring3 10GE-ports x710-4p10GE:
1431 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1432 - ring4 10GE-ports x710-4p10GE:
1433 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1436 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1440 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1441 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1442 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1443 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1444 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1445 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1448 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1452 - ring1 10GE-ports x710-4p10GE:
1453 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1454 - ring2 10GE-ports x710-4p10GE:
1455 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1456 - ring3 10GE-ports x710-4p10GE:
1457 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1458 - ring4 10GE-ports x710-4p10GE:
1459 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1462 #### 2-Node-Skylake Wiring (2n-skx) PROD
1466 - ring1 10GE-ports x710-4p10GE on SUT:
1467 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1468 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1469 - ring2 10GE-ports x710-4p10GE on SUT:
1470 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1471 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1472 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1473 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1474 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1476 - ring1 10GE-ports x710-4p10GE on SUT:
1477 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1478 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1479 - ring2 10GE-ports x710-4p10GE on SUT:
1480 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1481 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1482 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1483 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1484 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1486 - ring1 10GE-ports x710-4p10GE on SUT:
1487 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1488 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1489 - ring2 10GE-ports x710-4p10GE on SUT:
1490 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1491 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1492 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1493 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1494 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1496 - ring1 10GE-ports x710-4p10GE on SUT:
1497 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1498 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1499 - ring2 10GE-ports x710-4p10GE on SUT:
1500 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1501 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1502 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1503 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1504 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1507 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1511 - ring1 10GE-ports x553 copper port on SUT:
1512 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1513 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1514 - ring2 10GE-ports x553 fiber port on SUT:
1515 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1516 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1519 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1523 - link1 10GE-port x710-4p10GE on SUT:
1524 - t25-tg1-p1 to t25-sut1-c2/p1.
1525 - link2 10GE-port x710-4p10GE on SUT:
1526 - t25-tg1-p2 to t25-sut1-c2/p2.
1527 - link3 10GE-port x710-4p10GE on SUT:
1528 - t25-tg1-p3 to t25-sut1-c2/p3.
1529 - link4 10GE-port x710-4p10GE on SUT:
1530 - t25-tg1-p4 to t25-sut1-c2/p4.
1533 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1537 - ring1 10GE-ports x710-4p10GE on SUT:
1538 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1539 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1540 - ring2 10GE-ports x710-4p10GE on SUT:
1541 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1542 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1543 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1544 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1545 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1546 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1547 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1548 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1550 - ring1 10GE-ports x710-4p10GE on SUT:
1551 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1552 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1553 - ring2 10GE-ports x710-4p10GE on SUT:
1554 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1555 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1556 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1557 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1558 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1559 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1560 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1561 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1563 - ring1 10GE-ports x710-4p10GE on SUT:
1564 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1565 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1566 - ring2 10GE-ports x710-4p10GE on SUT:
1567 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1568 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1569 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1570 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1571 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1572 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1573 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1574 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1577 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1581 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1582 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1583 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1584 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1585 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1586 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1587 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1588 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1589 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1590 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1591 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1592 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1593 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1594 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1595 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1596 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1597 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1598 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1599 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1600 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1601 - TG loopback ports Intel NIC x710 2p10GE
1602 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1605 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1606 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1607 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1608 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1609 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1610 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1611 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1612 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1613 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1614 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1615 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1616 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1617 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1618 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1619 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1620 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1621 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1622 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1623 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1624 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1625 - TG loopback ports Intel NIC x710 2p10GE
1626 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1629 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1630 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1631 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1632 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1633 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1634 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1635 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1636 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1637 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1638 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1639 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1640 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1641 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1642 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1643 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1644 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1645 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1646 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1647 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1648 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1649 - TG loopback ports Intel NIC x710 2p10GE
1650 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1653 #### 3-Node-Skylake Wiring (3n-skx) PROD
1657 - ring1 10GE-ports x710-4p10GE on SUTs:
1658 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1659 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1660 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1661 - ring2 10GE-ports x710-4p10GE on SUT:
1662 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1663 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1664 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1665 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1666 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1667 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1668 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1669 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1670 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1671 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1672 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1673 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1674 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1675 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1677 - ring1 10GE-ports x710-4p10GE on SUTs:
1678 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1679 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1680 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1681 - ring2 10GE-ports x710-4p10GE on SUT:
1682 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1683 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1684 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1685 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1686 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1687 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1688 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1689 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1690 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1691 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1692 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1693 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1694 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1695 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1698 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1704 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1708 - ring1 10GE-ports x520-2p10GE on SUTs:
1709 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1710 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1711 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1712 - ring2 25GE-ports cx4-2p25GE on SUTs:
1713 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1714 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1715 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1718 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1722 - ring1 10GE-ports Marvell on SUTs:
1723 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1724 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1725 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1728 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1732 - ring1 10GE-ports x553 copper port on SUTs:
1733 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1734 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1735 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1736 - ring2 10GE-ports x553 fiber port on SUTs:
1737 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1738 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1739 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1747 1. Ixia PerfectStorm One Appliance
1749 - Chassis: PS10GE4NG.
1750 - Motherboard: SuperMicro X11DPG-QT.
1751 - Processors: Quad-Core, Intel Processor.
1752 - HW accelerators: FPGA offload.
1754 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1755 - Physical Interfaces: 4 * 10GE SFP+.
1756 - Operating System: Native IxOS.
1762 1. Arm Cortex A-72 servers
1764 - Chassis: Marvell ThunderX2
1765 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1766 - RAM Memory: 4* 32GB RDIMM
1767 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1768 - 2 * Huawei TaiShan 2280.
1769 - Chassis: Huawei TaiShan 2280.
1770 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1771 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1772 - Disks: 1* 4TB SATA HDD.
1774 - Chassis: MACCHIATObin.
1775 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1776 - RAM Memory: 1* 16GB DDR4.
1777 - Disks: 1* 128GB(?) SATA SDD.
1780 ### Xeon and Atom Servers
1783 1. Intel Xeon servers:
1784 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1785 - Chassis: SuperMicro SYS-7049GP-TRT.
1786 - Motherboard: SuperMicro X11DPG-QT.
1787 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1788 - RAM Memory: 16* 16GB DDR4-2666MHz.
1789 - Disks: 2* 1.6TB 6G SATA SSD.
1790 2. Intel Atom servers with Rangely processors.
1791 - 3 * Netgate XG-2758-1u
1792 - Chassis: Netgate XG-2758-1u
1793 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1794 - RAM Memory: 16GB ECC
1798 ### Network Interface Cards
1802 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1803 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1804 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1806 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1808 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1810 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1813 ### Pluggables and Cables
1819 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1820 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1826 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1837 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable