1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
16 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
18 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
34 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
36 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
37 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
38 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
39 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
40 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
41 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
48 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
51 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
52 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
53 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
54 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
55 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
75 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
76 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
77 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
78 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
79 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
80 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
81 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
82 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
83 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
84 10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0
85 11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
86 12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
87 13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
88 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
89 15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
90 Totals: 27 36 18 12 19 1 2 3 3 2 7 2
93 ### 1-Node-Skylake Xeon Intel (1n-skx)
95 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
96 ports connected back-to-back ([Server Types](#server-types)).
97 Used for FD.io VPP_Device functional driver tests.
99 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
101 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
102 ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
105 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
107 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
108 NIC ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
112 ### 2-Node-Skylake Xeon Intel (2n-skx)
114 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
115 (Server-Type-B2) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
147 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
149 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
150 one TG (Server-Type-B12) connected in a 2-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
154 ### 3-Node-Haswell Xeon Intel (3n-hsw)
156 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
157 TG (Server-Type-A2) connected in a 3-node circular topology
158 ([Server Types](#server-types)).
159 Used for FD.io performance tests.
161 ### 3-Node-Skylake Xeon Intel (3n-skx)
163 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
164 TG (Server-Type-B2) connected in a 3-node circular topology.
165 Used for FD.io performance tests.
167 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
169 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
170 TG (Server-Type-B12) connected in a 3-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
174 ### 3-Node-Rangeley Atom Testbeds
176 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
177 TG (Server-Type-2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
185 For management purposes, each server must have following two ports
186 connected to the management network:
190 - IPMI - Intelligent Platform Management Interface.
191 - Required for access to embedded server management with WebUI, CLI,
192 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
193 - 1GE/10GE/40GE management port
194 - hostOS management port for general system management.
199 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
200 Management port, which are connected to two different VLANs.
204 - Subnet: 10.30.50.0/24
205 - Gateway: 10.30.50.1
206 - Broadcast: 10.30.50.255
207 - DNS1: 199.204.44.24
208 - DNS2: 199.204.47.54
210 - Subnet: 10.30.51.0/24
211 - Gateway: 10.30.51.1
212 - Broadcast: 10.30.51.255
213 - DNS1: 199.204.44.24
214 - DNS2: 199.204.47.54
217 To access these hosts, VPN connection is required.
219 ### LOM (IPMI) VLAN IP Addresses
222 ------------ | -------
225 10.30.50.2 | LF Reserved
226 10.30.50.3 | LF Reserved
227 10.30.50.4 | LF Reserved
228 10.30.50.5 | LF Reserved
229 10.30.50.6 | LF Reserved
230 10.30.50.7 | LF Reserved
231 10.30.50.8 | LF Reserved
232 10.30.50.9 | LF Reserved
233 10.30.50.10 | LF Reserved
234 10.30.50.11 | LF Reserved
235 10.30.50.12 | LF Reserved
236 10.30.50.13 | LF Reserved
237 10.30.50.14 | LF Reserved
238 10.30.50.15 | LF Reserved
240 10.30.50.17 | t1-sut1
241 10.30.50.18 | t1-sut2
243 10.30.50.21 | t2-sut1
244 10.30.50.22 | t2-sut2
246 10.30.50.25 | t3-sut1
247 10.30.50.26 | t3-sut-2
248 10.30.50.28 | s41-nomad
249 10.30.50.29 | s39-nomad
250 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
251 10.30.50.30 | s40-nomad
252 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
253 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
254 10.30.50.32 | s42-nomad
255 10.30.50.33 | s43-nomad
256 10.30.50.34 | s44-nomad
257 10.30.50.35 | s45-nomad
258 10.30.50.36 | s17-t33-sut1
259 10.30.50.37 | s18-t33-sut2
260 10.30.50.38 | fdio-marvell-dev
261 10.30.50.39 | s53-nomad
262 10.30.50.40 | s54-nomad
263 10.30.50.41 | s3-t21-sut1
264 10.30.50.42 | s4-t21-tg1
265 10.30.50.43 | s11-t31-sut1
266 10.30.50.44 | s12-t31-sut2
267 10.30.50.45 | s13-t31-tg1
268 10.30.50.46 | s19-t33t34-tg1
269 10.30.50.47 | s1-t11-sut1
270 10.30.50.48 | s2-t12-sut1
271 10.30.50.49 | s5-t22-sut1
272 10.30.50.50 | s6-t22-tg1
273 10.30.50.51 | s7-t23-sut1
274 10.30.50.52 | s8-t23-tg1
275 10.30.50.53 | s9-t24-sut1
276 10.30.50.54 | s10-t24-tg1
277 10.30.50.55 | s14-t32-sut1
278 10.30.50.56 | s15-t32-sut2
279 10.30.50.57 | s16-t32-tg1
280 10.30.50.58 | s25-t25-sut1
281 10.30.50.59 | s26-t25-tg1
282 10.30.50.65 | s52-nomad
283 10.30.50.66 | s51-nomad
284 10.30.50.67 | s49-nomad
285 10.30.50.68 | s50-nomad
286 10.30.50.69 | s27-t34-sut1
287 10.30.50.70 | s55-t36-sut1
288 10.30.50.71 | s56-t37-sut1
289 10.30.50.255 | Broadcast
294 10.30.55.10 | s28-t26t35-tg1
295 10.30.55.11 | s29-t26-sut1
296 10.30.55.12 | s30-t35-sut1
297 10.30.55.13 | s31-t35-sut2
298 10.30.55.14 | s46-nomad
299 10.30.55.15 | s47-nomad
300 10.30.55.16 | s48-nomad
301 10.30.55.17 | s57-nomad
302 10.30.55.18 | s33-t27-sut1
303 10.30.55.19 | s34-t27-tg1
304 10.30.55.20 | s35-t28-sut1
305 10.30.55.21 | s36-t28-tg1
306 10.30.55.22 | s37-t29-sut1
307 10.30.55.23 | s38-t29-tg1
308 10.30.55.24 | s60-t210-sut1
309 10.30.55.25 | s61-t210-tg1
310 10.30.55.255 | Broadcast
312 ### Management VLAN IP Addresses
315 ------------------------- | -------
318 10.30.51.2 | LF Reserved
319 10.30.51.3 | LF Reserved
320 10.30.51.4 | LF Reserved
321 10.30.51.5 | LF Reserved
322 10.30.51.6 | LF Reserved
323 10.30.51.7 | LF Reserved
324 10.30.51.8 | LF Reserved
325 10.30.51.9 | s22-t35-sut1 (netgate-1)
326 10.30.51.10 | s23-t35-sut2 (netgate-2)
327 10.30.51.11 | s24-t35-sut3 (netgate-3)
328 10.30.51.12 | softiron-1 (decommissioned)
329 10.30.51.13 | softiron-2 (decommissioned)
330 10.30.51.14 | softiron-3 (decommissioned)
331 10.30.51.15 | LF Reserved
333 10.30.51.17 | t1-sut1
334 10.30.51.18 | t1-sut2
336 10.30.51.21 | t2-sut1
337 10.30.51.22 | t2-sut2
339 10.30.51.25 | t3-sut1
340 10.30.51.26 | t3-sut-2
341 10.30.51.28 | s41-nomad
342 10.30.51.29 | s39-nomad
343 10.30.51.30 | s40-nomad
344 10.30.51.32 | s42-nomad
345 10.30.51.33 | s43-nomad
346 10.30.51.34 | s44-nomad
347 10.30.51.35 | s45-nomad
348 10.30.51.36 | s17-t33-sut1
349 10.30.51.37 | s18-t33-sut2
350 10.30.51.38 | fdio-marvell-dev
351 10.30.51.39 | s53-nomad
352 10.30.51.40 | s54-nomad
353 10.30.51.41 | s20-t34-sut1 (decommissioned)
354 10.30.51.42 | s21-t34-sut2 (decommissioned)
355 10.30.51.43 | fdio-mcbin3 (decommissioned)
356 10.30.51.44 | s3-t21-sut1
357 10.30.51.45 | s4-t21-tg1
358 10.30.51.46 | s11-t31-sut1
359 10.30.51.47 | s12-t31-sut2
360 10.30.51.48 | s13-t31-tg1
361 10.30.51.49 | s19-t33t34-tg1
362 10.30.51.50 | s1-t11-sut1
363 10.30.51.51 | s2-t12-sut1
364 10.30.51.52 | s5-t22-sut1
365 10.30.51.53 | s6-t22-tg1
366 10.30.51.54 | s7-t23-sut1
367 10.30.51.55 | s8-t23-tg1
368 10.30.51.56 | s9-t24-sut1
369 10.30.51.57 | s10-t24-tg1
370 10.30.51.58 | s14-t32-sut1
371 10.30.51.59 | s15-t32-sut2
372 10.30.51.60 | s16-t32-tg1
373 10.30.51.61 | s25-t25-sut1
374 10.30.51.62 | s26-t25-tg1
375 10.30.51.65 | s52-nomad
376 10.30.51.66 | s51-nomad
377 10.30.51.67 | s49-nomad
378 10.30.51.68 | s50-nomad
379 10.30.51.69 | s27-t34-sut1
380 10.30.51.70 | s55-t36-sut1
381 10.30.51.71 | s56-t37-sut1
382 10.30.51.72-10.30.51.105 | FREE
383 10.30.51.106-10.30.51.180 | FREE
384 10.30.51.181-10.30.51.254 | FREE
385 10.30.51.255 | Broadcast
388 10.32.8.10 | s28-t26t35-tg1
389 10.32.8.11 | s29-t26-sut1
390 10.32.8.12 | s30-t35-sut1
391 10.32.8.13 | s31-t35-sut2
392 10.32.8.14 | s46-nomad
393 10.32.8.15 | s47-nomad
394 10.32.8.16 | s48-nomad
395 10.32.8.17 | s57-nomad
396 10.32.8.18 | s33-t27-sut1
397 10.32.8.19 | s34-t27-tg1
398 10.32.8.20 | s35-t28-sut1
399 10.32.8.21 | s36-t28-tg1
400 10.32.8.22 | s37-t29-sut1
401 10.32.8.23 | s38-t29-tg1
402 10.32.8.24 | s60-t210-sut1
403 10.32.8.25 | s61-t210-tg1
404 10.32.8.255 | Broadcast
406 ## Server Specifications
410 FD.io CSIT lab contains following server types:
412 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
413 - Quantity: 6 servers.
414 - Physical connectivity:
415 - CIMC and host management ports.
416 - NIC ports connected in 3-node topologies.
417 - Main HW configuration:
418 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419 - Processors: 2* E5-2699v3 2.3 GHz.
420 - RAM Memory: 16* 32GB DDR4-2133MHz.
421 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
422 - NICs configuration:
423 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
424 - PCIe Slot1: Cisco VIC 1385 2p40GE.
425 - PCIe Slot2: Intel NIC x520 2p10GE.
427 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
428 - PCIe Slot4: Intel NIC xl710 2p40GE.
429 - PCIe Slot5: Intel NIC x710 2p10GE.
430 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
431 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
432 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
433 - Quantity: 3 servers.
434 - Physical connectivity:
435 - CIMC and host management ports.
436 - NIC ports connected in 3-node topologies.
437 - Main HW configuration:
438 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
439 - Processors: 2* E5-2699v3 2.3 GHz.
440 - RAM Memory: 16* 32GB DDR4-2133MHz.
441 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
442 - NICs configuration:
443 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
444 - PCIe Slot1: Intel NIC xl710 2p40GE.
445 - PCIe Slot2: Intel NIC x710 2p10GE.
446 - PCIe Slot3: Intel NIC x710 2p10GE.
447 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
448 - PCIe Slot4: Intel NIC xl710 2p40GE.
449 - PCIe Slot5: Intel NIC x710 2p10GE.
450 - PCIe Slot6: Intel NIC x710 2p10GE.
452 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
453 - Quantity: 3 servers.
454 - Physical connectivity:
455 - CIMC and host management ports.
456 - no NIC ports, standalone setup.
457 - Main HW configuration:
458 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
459 - Processors: 2* E5-2699v3 2.3 GHz.
460 - RAM Memory: 16* 32GB DDR4-2133MHz.
461 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
462 - NICs configuration:
463 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
465 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
468 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
470 - Physical connectivity:
471 - IPMI and host management ports.
472 - NIC ports connected into 2-node and 3-node topologies.
473 - Main HW configuration:
474 - Chassis: SuperMicro SYS-7049GP-TRT.
475 - Motherboard: SuperMicro X11DPG-QT.
476 - Processors: 2* Intel Platinum 8180 2.5 GHz.
477 - RAM Memory: 16* 16GB DDR4-2666MHz.
478 - Disks: 2* 1.6TB 6G SATA SSD.
479 - NICs configuration:
480 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
481 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
482 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
483 - PCIe Slot9 5e:00.xx: empty.
484 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
485 - PCIe Slot6 86:00.xx: empty.
486 - PCIe Slot8 af:00.xx: empty.
487 - PCIe Slot10 d8:00.xx: empty.
488 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
490 - Physical connectivity:
491 - IPMI and host management ports.
492 - NIC ports connected into 2-node and 3-node topologies.
493 - Main HW configuration:
494 - Chassis: SuperMicro SYS-7049GP-TRT.
495 - Motherboard: SuperMicro X11DPG-QT.
496 - Processors: 2* Intel Platinum 8180 2.5 GHz.
497 - RAM Memory: 16* 16GB DDR4-2666MHz.
498 - Disks: 2* 1.6TB 6G SATA SSD.
499 - NICs configuration:
500 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
501 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
502 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
503 - PCIe Slot9 5e:00.xx: empty.
504 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
505 - PCIe Slot6 86:00.xx: empty.
506 - PCIe Slot8 af:00.xx: empty.
507 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
508 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
510 - Physical connectivity:
511 - IPMI(?) and host management ports.
512 - NIC ports connected into 3-node topology.
513 - Main HW configuration:
514 - Chassis: Huawei TaiShan 2280.
515 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
516 - RAM Memory: 8* 16GB DDR4-2400MT/s
517 - Disks: 1* 4TB SATA HDD
518 - NICs configuration:
519 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
520 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
521 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
522 - Quantity: TBD based on testbed allocation.
523 - Physical connectivity:
524 - Management: serial Port (usb) for console
525 - NIC ports connected into 2-node.
526 - Main HW configuration:
527 - Chassis: Netgate XG-2758-1u
528 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
529 - RAM Memory: 16GB ECC
531 - NICs configuration:
532 - 2x 10Gb Intel 82599ES
534 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
536 - Physical connectivity:
537 - IPMI and host management ports.
538 - NIC ports connected into 1-node topologies.
539 - Main HW configuration:
540 - Chassis: SuperMicro SYS-7049GP-TRT.
541 - Motherboard: SuperMicro X11DPG-QT.
542 - Processors: 2* Intel Platinum 8180 2.5 GHz.
543 - RAM Memory: 16* 16GB DDR4-2666MHz.
544 - Disks: 2* 1.6TB 6G SATA SSD.
545 - NICs configuration:
546 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
547 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
548 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
549 - PCIe Slot9 5e:00.xx: empty.
550 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
551 - PCIe Slot6 86:00.xx: empty.
552 - PCIe Slot8 af:00.xx: empty.
553 - PCIe Slot10 d8:00.xx: empty.
554 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
556 - Physical connectivity:
557 - Host management interface: 10/100/1000-BaseT.
558 - 8-port 10GE SFP+ integrated NIC.
559 - Main HW configuration:
560 - Chassis: PS10GE4NG.
561 - Motherboard: SuperMicro X11DPG-QT.
562 - Processors: Quad-Core, Intel Processor.
563 - HW accelerators: FPGA offload.
565 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
566 - Physical Interfaces: 4 * 10GE SFP+.
567 - Operating System: Native IxOS.
568 - Interface configuration:
573 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
575 - Physical connectivity:
576 - IPMI and host management ports.
578 - Main HW configuration:
579 - Chassis: SuperMicro SYS-7049GP-TRT.
580 - Motherboard: SuperMicro X11DPG-QT.
581 - Processors: 2* Intel Platinum 8180 2.5 GHz.
582 - RAM Memory: 16* 16GB DDR4-2666MHz.
583 - Disks: 2* 1.6TB 6G SATA SSD.
584 - NICs configuration:
585 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
586 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
587 - PCIe Slot4 3b:00.xx: empty.
588 - PCIe Slot9 5e:00.xx: empty.
589 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
590 - PCIe Slot6 86:00.xx: empty.
591 - PCIe Slot8 af:00.xx: empty.
592 - PCIe Slot10 d8:00.xx: empty.
593 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
595 - Physical connectivity:
596 - IPMI and host management ports.
597 - NIC ports connected into 1-node topologies.
598 - Main HW configuration:
599 - Chassis: Gigabyte R181-T90 1U
600 - Motherboard: MT91-FS1
601 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
602 - RAM Memory: 4* 32GB RDIMM
603 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
604 - NICs configuration:
606 - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
608 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
609 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
611 - Physical connectivity:
612 - IPMI and host management ports.
614 - Main HW configuration:
615 - Chassis: SuperMicro SYS-E300-9A
616 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
617 - RAM Memory: 32GB ECC
619 - NICs configuration:
620 - 2x 10Gb Intel x553 fiber ports
621 - 2x 10Gb Intel x553 copper ports
622 - 4x 1GB Intel I350 ports
623 13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
625 - Physical connectivity:
626 - IPMI and host management ports.
627 - NIC ports connected into 1-node topologies.
628 - Main HW configuration:
629 - Chassis: GIGABYTE Rack Mount
630 - Motherboard: MT91-FS4-00
631 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
632 - RAM Memory: 16 * 16GB DIMM
633 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
634 - NICs configuration:
636 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
637 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
639 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
640 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
641 14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
643 - Physical connectivity:
644 - IPMI and host management ports.
645 - NIC ports connected into 2-node and 3-node topologies.
646 - Main HW configuration:
647 - Chassis: SuperMicro SYS-7049GP-TRT.
648 - Motherboard: SuperMicro X11DPG-QT.
649 - Processors: 2* Intel Platinum 8180 2.5 GHz.
650 - RAM Memory: 16* 16GB DDR4-2666MHz.
651 - Disks: 2* 1.6TB 6G SATA SSD.
652 - NICs configuration:
653 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
654 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
655 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
656 - PCIe Slot9 5e:00.xx: empty.
657 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
658 - PCIe Slot6 86:00.xx: empty.
659 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
660 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
662 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
664 - Physical connectivity:
665 - IPMI and host management ports.
666 - NIC ports connected into 1-node testbed topologies.
667 - Main HW configuration:
668 - Chassis: SuperMicro SYS-7049GP-TRT.
669 - Motherboard: SuperMicro X11DPG-QT.
670 - Processors: 2* Intel Platinum 8280 2.7 GHz.
671 - RAM Memory: 12* 16GB DDR4-2933.
672 - Disks: 2* 1.92TB SATA SSD.
673 - NICs configuration:
674 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
675 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
676 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
677 - PCIe Slot9 5e:00.xx: empty.
678 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
679 - PCIe Slot6 86:00.xx: empty.
680 - PCIe Slot8 af:00.xx: empty.
681 - PCIe Slot10 d8:00.xx: empty.
682 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
684 - Physical connectivity:
685 - IPMI and host management ports.
686 - NIC ports connected into 2-node testbed topologies.
687 - Main HW configuration:
688 - Chassis: SuperMicro SYS-7049GP-TRT.
689 - Motherboard: SuperMicro X11DPG-QT.
690 - Processors: 2* Intel Gold 6252N 2.3 GHz.
691 - RAM Memory: 12* 16GB DDR4-2933.
692 - Disks: 2* 1.92TB SATA SSD.
693 - NICs configuration:
694 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
695 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
696 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
697 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
698 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
699 - PCIe Slot6 86:00.xx: empty.
700 - PCIe Slot8 af:00.xx: empty.
701 - PCIe Slot10 d8:00.xx: empty.
702 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
704 - Physical connectivity:
705 - IPMI and host management ports.
706 - NIC ports connected into 2-node testbed topologies.
707 - Main HW configuration:
708 - Chassis: SuperMicro SYS-7049GP-TRT.
709 - Motherboard: SuperMicro X11DPG-QT.
710 - Processors: 2* Intel Platinum 8280 2.7 GHz.
711 - RAM Memory: 12* 16GB DDR4-2933.
712 - Disks: 2* 1.92TB SATA SSD.
713 - NICs configuration:
714 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
715 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
716 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
717 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
718 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
719 - PCIe Slot6 86:00.xx: empty.
720 - PCIe Slot8 af:00.xx: empty.
721 - PCIe Slot10 d8:00.xx: empty.
722 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
724 - Physical connectivity:
725 - CIMC and host management ports.
726 - no NIC ports, standalone setup.
727 - Main HW configuration:
728 - Chassis: SuperMicro 1029P-WTRT.
729 - Motherboard: SuperMicro X11DDW-NT.
730 - Processors: 2* Intel Platinum 8280 2.7 GHz.
731 - RAM Memory: 12* 16GB DDR4-2933.
732 - Disks: 4* 1.92TB SATA SSD.
733 - NICs configuration:
739 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
741 - Physical connectivity:
742 - IPMI and host management ports.
743 - NIC ports connected into 2-node testbed topologies.
744 - Main HW configuration:
745 - Chassis: SuperMicro AS-1114S-WTRT
746 - Processors: 1* AMD EPYC 7532 2.4 GHz.
747 - RAM Memory: 8* 32GB DDR4-2933.
748 - Disks: 1* 1TB SATA SSD.
749 - NICs configuration:
750 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
751 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
752 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
753 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
754 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
756 - Physical connectivity:
757 - IPMI and host management ports.
758 - NIC ports connected into 2-node testbed topologies.
759 - Main HW configuration:
760 - Chassis: SuperMicro AS-1114S-WTRT
761 - Processors: 1* AMD EPYC 7532 2.4 GHz.
762 - RAM Memory: 8* 32GB DDR4-2933.
763 - Disks: 1* 1TB SATA SSD.
764 - NICs configuration:
765 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
766 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
767 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
768 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
771 ### Naming Convention
773 Following naming convention is used within this page to specify physical
774 connectivity and wiring across defined CSIT testbeds:
777 - testbedname: testbedN.
779 - traffic-generator: tN-tgW.
780 - system-under-testX: tN-sutX.
785 - N - testbed number.
786 - tgW - server acts as traffic-generator with W index.
787 - sutX - server acts as system-under-test with X index.
788 - Y - PCIe slot number denoting a NIC card number within the host.
789 - Z - port number on the NIC card.
792 ## Testbeds Configuration
794 ### Per Testbed Server Allocation and Naming
796 #### 1-Node-Skylake Servers (1n-skx) PROD
799 - SUT [Server-Type-B6]:
800 - testbedname: testbed11.
801 - hostname: s1-t11-sut1.
802 - IPMI IP: 10.30.50.47
803 - Host IP: 10.30.51.50
805 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
806 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
807 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
808 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
809 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
810 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
811 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
812 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
813 - SUT [Server-Type-B6]:
814 - testbedname: testbed12.
815 - hostname: s2-t12-sut1.
816 - IPMI IP: 10.30.50.48
817 - Host IP: 10.30.51.51
819 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
820 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
821 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
822 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
823 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
824 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
825 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
826 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
829 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
832 - SUT [Server-Type-B11]:
833 - testbedname: testbed36
834 - hostname: s55-t36-sut1
835 - IPMI IP: 10.30.50.70
836 - Host IP: 10.30.51.70
838 - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
839 - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
840 - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
841 - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
842 - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
843 - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
844 - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
845 - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
846 - SUT [Server-Type-B11]:
847 - testbedname: testbed37
848 - hostname: s56-t37-sut1
849 - IPMI IP: 10.30.50.71
850 - Host IP: 10.30.51.71
852 - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
853 - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
854 - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
855 - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
856 - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
857 - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
858 - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
859 - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
862 #### 1-Node-Cascadelake Servers (1n-clx) PROD
865 - SUT [Server-Type-C1]:
866 - testbedname: testbed11.
867 - hostname: s32-t14-sut1.
868 - IPMI IP: 10.30.55.17
869 - Host IP: 10.32.8.17
871 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
872 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
873 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
874 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
875 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
876 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
877 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
878 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
881 #### 2-Node-Skylake Servers (2n-skx) PROD
884 - SUT [Server-Type-B1]:
885 - testbedname: testbed21.
886 - hostname: s3-t21-sut1.
887 - IPMI IP: 10.30.50.41
888 - Host IP: 10.30.51.44
890 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
891 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
892 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
893 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
894 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
895 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
896 - TG [Server-Type-B2]:
897 - testbedname: testbed21.
898 - hostname: s4-t21-tg1.
899 - IPMI IP: 10.30.50.42
900 - Host IP: 10.30.51.45
902 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
903 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
904 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
905 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
906 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
907 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
908 - SUT [Server-Type-B1]:
909 - testbedname: testbed22.
910 - hostname: s5-t22-sut1.
911 - IPMI IP: 10.30.50.49
912 - Host IP: 10.30.51.52
914 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
915 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
916 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
917 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
918 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
919 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
920 - TG [Server-Type-B2]:
921 - testbedname: testbed22.
922 - hostname: s6-t22-tg1.
923 - IPMI IP: 10.30.50.50
924 - Host IP: 10.30.51.53
926 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
927 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
928 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
929 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
930 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
931 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
932 - SUT [Server-Type-B1]:
933 - testbedname: testbed23.
934 - hostname: s7-t23-sut1.
935 - IPMI IP: 10.30.50.51
936 - Host IP: 10.30.51.54
938 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
939 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
940 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
941 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
942 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
943 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
944 - TG [Server-Type-B2]:
945 - testbedname: testbed23.
946 - hostname: s8-t23-tg1.
947 - IPMI IP: 10.30.50.52
948 - Host IP: 10.30.51.55
950 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
951 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
952 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
953 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
954 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
955 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
956 - SUT [Server-Type-B1]:
957 - testbedname: testbed24.
958 - hostname: s9-t24-sut1.
959 - IPMI IP: 10.30.50.53
960 - Host IP: 10.30.51.56
962 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
963 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
964 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
965 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
966 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
967 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
968 - TG [Server-Type-B2]:
969 - testbedname: testbed24.
970 - hostname: s10-t24-tg1.
971 - IPMI IP: 10.30.50.54
972 - Host IP: 10.30.51.57
974 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
975 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
976 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
977 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
978 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
979 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
982 #### 2-Node-Denverton Servers (2n-dnv) WIP
984 Note: ServerB28 (TG) is shared between testbed26 & testbed35
987 - TG [Server-Type-B2]:
988 - testbednames: testbed26 and testbed35.
989 - hostname: s28-t26t35-tg1.
990 - IPMI IP: 10.30.55.10
991 - Host IP: 10.32.8.10
993 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
994 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
995 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
996 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
997 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
998 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
999 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1000 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1001 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1002 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1003 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1004 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1005 - SUT [Server-Type-B10]:
1006 - testbednames: testbed26.
1007 - hostname: s29-t26-sut1.
1008 - IPMI IP: 10.30.55.11
1009 - Host IP: 10.32.8.11
1011 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1012 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1013 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1014 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1017 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1020 - SUT [Server-Type-B8]:
1021 - testbedname: testbed25.
1022 - hostname: s25-t25-sut1.
1023 - IPMI IP: 10.30.50.58
1024 - Host IP: 10.30.51.61
1026 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1027 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1028 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1029 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1030 - TG [Server-Type-B7]:
1031 - testbedname: testbed25.
1032 - hostname: s26-t25-tg1.
1033 - IPMI IP: 10.30.50.59
1034 - Host IP: 10.30.51.62
1036 - s26-t25-tg1-p1 - 10GE-port1.
1037 - s26-t25-tg1-p2 - 10GE-port2.
1038 - s26-t25-tg1-p3 - 10GE-port3.
1039 - s26-t25-tg1-p4 - 10GE-port4.
1042 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1045 - SUT [Server-Type-C2]:
1046 - testbedname: testbed27.
1047 - hostname: s33-t27-sut1.
1048 - IPMI IP: 10.30.55.18
1049 - Host IP: 10.32.8.18
1051 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1052 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1053 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1054 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1055 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1056 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1057 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1058 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1059 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1060 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1061 - TG [Server-Type-C3]:
1062 - testbedname: testbed27.
1063 - hostname: s34-t27-tg1.
1064 - IPMI IP: 10.30.55.19
1065 - Host IP: 10.32.8.19
1067 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1068 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1069 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1070 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1071 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1072 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1073 - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1074 - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1075 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1076 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1077 - SUT [Server-Type-C2]:
1078 - testbedname: testbed28.
1079 - hostname: s35-t28-sut1.
1080 - IPMI IP: 10.30.55.20
1081 - Host IP: 10.32.8.20
1083 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1084 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1085 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1086 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1087 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1088 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1089 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1090 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1091 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1092 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1093 - TG [Server-Type-C3]:
1094 - testbedname: testbed28.
1095 - hostname: s36-t28-tg1.
1096 - IPMI IP: 10.30.55.21
1097 - Host IP: 10.32.8.21
1099 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1100 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1101 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1102 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1103 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1104 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1105 - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1106 - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1107 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1108 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1109 - SUT [Server-Type-C2]:
1110 - testbedname: testbed29.
1111 - hostname: s37-t29-sut1.
1112 - IPMI IP: 10.30.55.22
1113 - Host IP: 10.32.8.22
1115 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1116 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1117 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1118 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1119 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1120 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1121 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1122 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1123 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1124 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1125 - TG [Server-Type-C3]:
1126 - testbedname: testbed29.
1127 - hostname: s38-t29-tg1.
1128 - IPMI IP: 10.30.55.23
1129 - Host IP: 10.32.8.23
1131 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1132 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1133 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1134 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1135 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137 - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1138 - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1139 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1140 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1143 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1146 - SUT [Server-Type-D1]:
1147 - testbedname: testbed210.
1148 - hostname: s60-t210-sut1.
1149 - IPMI IP: 10.30.55.24
1150 - Host IP: 10.32.8.24
1152 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1153 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1154 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1155 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1156 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1157 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1158 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1159 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1160 - TG [Server-Type-D2]:
1161 - testbedname: testbed210.
1162 - hostname: s61-t210-tg1.
1163 - IPMI IP: 10.30.55.25
1164 - Host IP: 10.32.8.25
1166 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1167 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1168 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1169 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1170 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1171 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1172 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1173 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1176 #### 2-Node-ThunderX2 Servers (2x-tx2) WIP
1178 Note: Server19 (TG) is shared between testbed33 & testbed34
1181 - SUT [Server-Type-B9]:
1182 - testbedname: testbed34.
1183 - hostname: s27-t34-sut1.
1184 - IPMI IP: 10.30.50.69
1185 - Host IP: 10.30.51.69
1187 - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1188 - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1189 - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1190 - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1191 - TG [Server-Type-B12]:
1192 - testbedname: testbed33 and testbed34.
1193 - hostname: s19-t33t34-tg1.
1194 - IPMI IP: 10.30.50.46
1195 - Host IP: 10.30.51.49
1197 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1198 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1199 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1200 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1201 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1202 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1203 - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1204 - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1205 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1206 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1207 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1208 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1211 #### 3-Node-Haswell Servers (3n-hsw) PROD
1214 1. SUT [Server-Type-A1]:
1215 - testbedname: testbed1.
1216 - hostname: t1-sut1.
1217 - CIMC IP: 10.30.50.17
1218 - Host IP: 10.30.51.17
1220 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1221 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1222 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1223 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1224 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1225 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1226 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1227 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1228 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1229 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1230 2. SUT [Server-Type-A1]:
1231 - testbedname: testbed1.
1232 - hostname: t1-sut2.
1233 - CIMC IP: 10.30.50.18
1234 - Host IP: 10.30.51.18
1236 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1237 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1238 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1239 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1240 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1241 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1242 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1243 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1244 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1245 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1246 3. TG [Server-Type-A2]:
1247 - testbedname: testbed1.
1249 - CIMC IP: 10.30.50.16
1250 - Host IP: 10.30.51.16
1252 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1253 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1254 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1255 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1256 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1257 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1258 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1259 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1260 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1261 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1262 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1263 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1264 4. SUT [Server-Type-A1]:
1265 - testbedname: testbed2.
1266 - hostname: t2-sut1.
1267 - CIMC IP: 10.30.50.21
1268 - Host IP: 10.30.51.21
1270 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1271 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1272 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1273 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1274 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1275 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1276 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1277 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1278 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1279 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1280 5. SUT [Server-Type-A1]:
1281 - testbedname: testbed2.
1282 - hostname: t2-sut2.
1283 - CIMC IP: 10.30.50.22
1284 - Host IP: 10.30.51.22
1286 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1287 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1288 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1289 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1290 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1291 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1292 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1293 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1294 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1295 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1296 6. TG [Server-Type-A2]:
1297 - testbedname: testbed2.
1299 - CIMC IP: 10.30.50.20
1300 - Host IP: 10.30.51.20
1302 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1303 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1304 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1305 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1306 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1307 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1308 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1309 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1310 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1311 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1312 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1313 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1314 7. SUT [Server-Type-A1]:
1315 - testbedname: testbed3.
1316 - hostname: t3-sut1.
1317 - CIMC IP: 10.30.50.25
1318 - Host IP: 10.30.51.25
1320 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1321 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1322 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1323 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1324 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1325 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1326 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1327 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1328 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1329 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1330 8. SUT [Server-Type-A1]:
1331 - testbedname: testbed3.
1332 - hostname: t3-sut2.
1333 - CIMC IP: 10.30.50.26
1334 - Host IP: 10.30.51.26
1336 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1337 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1338 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1339 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1340 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1341 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1342 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1343 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1344 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1345 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1346 9. TG [Server-Type-A2]:
1347 - testbedname: testbed3.
1349 - CIMC IP: 10.30.50.24
1350 - Host IP: 10.30.51.24
1352 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1353 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1354 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1355 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1356 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1357 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1358 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1359 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1360 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1361 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1362 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1363 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1366 #### 3-Node-Skylake Servers (3n-skx) PROD
1369 - ServerB11 [Server-Type-B1]:
1370 - testbedname: testbed31.
1371 - hostname: s11-t31-sut1.
1372 - IPMI IP: 10.30.50.43
1373 - Host IP: 10.30.51.46
1375 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1376 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1377 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1378 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1379 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1380 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1381 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1382 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1383 - ServerB12 [Server-Type-B1]:
1384 - testbedname: testbed31.
1385 - hostname: s12-t31-sut2.
1386 - IPMI IP: 10.30.50.44
1387 - Host IP: 10.30.51.47
1389 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1390 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1391 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1392 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1393 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1394 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1395 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1396 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1397 - ServerB13 [Server-Type-B2]:
1398 - testbedname: testbed31.
1399 - hostname: s13-t31-tg1.
1400 - IPMI IP: 10.30.50.45
1401 - Host IP: 10.30.51.48
1403 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1404 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1405 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1406 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1407 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1408 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1409 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1410 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1411 - ServerB14 [Server-Type-B1]:
1412 - testbedname: testbed32.
1413 - hostname: s14-t32-sut1.
1414 - IPMI IP: 10.30.50.55
1415 - Host IP: 10.30.51.58
1417 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1418 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1419 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1420 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1421 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1422 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1423 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1424 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1425 - ServerB15 [Server-Type-B1]:
1426 - testbedname: testbed32.
1427 - hostname: s15-t32-sut2.
1428 - IPMI IP: 10.30.50.56
1429 - Host IP: 10.30.51.59
1431 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1432 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1433 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1434 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1435 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1436 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1437 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1438 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1439 - ServerB16 [Server-Type-B2]:
1440 - testbedname: testbed32.
1441 - hostname: s16-t32-tg1.
1442 - IPMI IP: 10.30.50.57
1443 - Host IP: 10.30.51.60
1445 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1446 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1447 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1448 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1449 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1450 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1451 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1452 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1455 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1457 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1460 - ServerB22 [Server-Type-B5]:
1461 - testbedname: testbed35.
1462 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1463 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1464 - Host IP: 10.30.51.9
1466 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1467 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1469 - ServerB23 [Server-Type-B5]:
1470 - testbedname: testbed35.
1471 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1472 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1473 - Host IP: 10.30.51.10
1475 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1476 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1478 - ServerB24 [Server-Type-B5]:
1479 - testbedname: testbed35.
1480 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1481 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1482 - Host IP: 10.30.51.11
1484 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1485 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1489 #### 3-Node-Taishan Servers (3n-tsh) PROD
1491 Note: Server19 (TG) is shared between testbed33 & testbed34
1494 - SUT [Server-Type-B3]:
1495 - testbedname: testbed33.
1496 - hostname: s17-t33-sut1.
1497 - IPMI IP: 10.30.50.36
1498 - Host IP: 10.30.51.36
1500 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1501 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1502 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1503 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1504 - SUT [Server-Type-B3]:
1505 - testbedname: testbed33.
1506 - hostname: s18-t33-sut2.
1507 - IPMI IP: 10.30.50.37
1508 - Host IP: 10.30.51.37
1510 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1511 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1512 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1513 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1514 - TG [Server-Type-B12]:
1515 - testbedname: testbed33 and testbed34.
1516 - hostname: s19-t33t34-tg1.
1517 - IPMI IP: 10.30.50.46
1518 - Host IP: 10.30.51.49
1520 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1521 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1522 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1523 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1524 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1525 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1526 - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1527 - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1528 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1529 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1530 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1531 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1534 #### 3-Node-Denverton Servers (3n-dnv) WIP
1537 - ServerB30 [Server-Type-B10]:
1538 - testbednames: testbed35.
1539 - hostname: s30-t35-sut1.
1540 - IPMI IP: 10.30.55.12
1541 - Host IP: 10.32.8.12
1543 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1544 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1545 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1546 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1547 - ServerB31 [Server-Type-B10]:
1548 - testbednames: testbed35.
1549 - hostname: s31-t35-sut2.
1550 - IPMI IP: 10.30.55.13
1551 - Host IP: 10.32.8.13
1553 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1554 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1555 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1556 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1559 ### Per Testbed Wiring
1561 #### 1-Node-Skylake Wiring (1n-skx) PROD
1565 - ring1 10GE-ports x710-4p10GE:
1566 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1567 - ring2 10GE-ports x710-4p10GE:
1568 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1569 - ring3 10GE-ports x710-4p10GE:
1570 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1571 - ring4 10GE-ports x710-4p10GE:
1572 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1574 - ring1 10GE-ports x710-4p10GE:
1575 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1576 - ring2 10GE-ports x710-4p10GE:
1577 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1578 - ring3 10GE-ports x710-4p10GE:
1579 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1580 - ring4 10GE-ports x710-4p10GE:
1581 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1584 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1588 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1589 - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1590 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1591 - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1592 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1593 - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1594 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1595 - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1598 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1599 - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1600 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1601 - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1602 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1603 - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1604 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1605 - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1608 #### 1-Node-Cascadelake Wiring (1n-clx) PROD
1612 - ring1 10GE-ports x710-4p10GE:
1613 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1614 - ring2 10GE-ports x710-4p10GE:
1615 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1616 - ring3 10GE-ports x710-4p10GE:
1617 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1618 - ring4 10GE-ports x710-4p10GE:
1619 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1622 #### 2-Node-Skylake Wiring (2n-skx) PROD
1626 - ring1 10GE-ports x710-4p10GE on SUT:
1627 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1628 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1629 - ring2 10GE-ports x710-4p10GE on SUT:
1630 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1631 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1632 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1633 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1634 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1636 - ring1 10GE-ports x710-4p10GE on SUT:
1637 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1638 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1639 - ring2 10GE-ports x710-4p10GE on SUT:
1640 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1641 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1642 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1643 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1644 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1646 - ring1 10GE-ports x710-4p10GE on SUT:
1647 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1648 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1649 - ring2 10GE-ports x710-4p10GE on SUT:
1650 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1651 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1652 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1653 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1654 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1656 - ring1 10GE-ports x710-4p10GE on SUT:
1657 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1658 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1659 - ring2 10GE-ports x710-4p10GE on SUT:
1660 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1661 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1662 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1663 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1664 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1667 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1671 - ring1 10GE-ports x553 copper port on SUT:
1672 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1673 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1674 - ring2 10GE-ports x553 fiber port on SUT:
1675 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1676 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1679 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1683 - link1 10GE-port x710-4p10GE on SUT:
1684 - t25-tg1-p1 to t25-sut1-c2/p1.
1685 - link2 10GE-port x710-4p10GE on SUT:
1686 - t25-tg1-p2 to t25-sut1-c2/p2.
1687 - link3 10GE-port x710-4p10GE on SUT:
1688 - t25-tg1-p3 to t25-sut1-c2/p3.
1689 - link4 10GE-port x710-4p10GE on SUT:
1690 - t25-tg1-p4 to t25-sut1-c2/p4.
1693 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1697 - ring1 10GE-ports x710-4p10GE on SUT:
1698 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1699 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1700 - ring2 10GE-ports x710-4p10GE on SUT:
1701 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1702 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1703 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1704 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1705 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1706 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1707 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1708 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1709 - ring5 100GE-ports e810-2p100GE on SUT:
1710 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1711 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1713 - ring1 10GE-ports x710-4p10GE on SUT:
1714 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1715 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1716 - ring2 10GE-ports x710-4p10GE on SUT:
1717 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1718 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1719 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1720 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1721 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1722 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1723 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1724 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1725 - ring5 100GE-ports e810-2p100GE on SUT:
1726 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1727 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1729 - ring1 10GE-ports x710-4p10GE on SUT:
1730 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1731 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1732 - ring2 10GE-ports x710-4p10GE on SUT:
1733 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1734 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1735 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1736 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1737 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1738 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1739 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1740 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1741 - ring6 100GE-ports e810-2p100GE on SUT:
1742 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1743 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1746 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1750 - ring1 10GE-ports x710-4p10GE on SUT:
1751 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1752 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1753 - ring2 10GE-ports x710-4p10GE on SUT:
1754 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1755 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1756 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1757 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1758 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1759 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1760 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1761 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1764 #### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
1768 - ring1 10GE-ports x520-2p10GE on SUTs:
1769 - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
1770 - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
1774 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1778 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1779 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1780 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1781 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1782 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1783 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1784 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1785 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1786 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1787 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1788 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1789 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1790 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1791 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1792 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1793 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1794 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1795 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1796 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1797 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1798 - TG loopback ports Intel NIC x710 2p10GE
1799 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1802 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1803 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1804 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1805 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1806 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1807 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1808 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1809 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1810 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1811 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1812 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1813 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1814 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1815 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1816 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1817 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1818 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1819 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1820 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1821 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1822 - TG loopback ports Intel NIC x710 2p10GE
1823 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1826 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1827 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1828 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1829 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1830 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1831 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1832 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1833 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1834 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1835 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1836 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1837 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1838 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1839 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1840 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1841 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1842 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1843 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1844 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1845 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1846 - TG loopback ports Intel NIC x710 2p10GE
1847 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1850 #### 3-Node-Skylake Wiring (3n-skx) PROD
1854 - ring1 10GE-ports x710-4p10GE on SUTs:
1855 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1856 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1857 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1858 - ring2 10GE-ports x710-4p10GE on SUT:
1859 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1860 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1861 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1862 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1863 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1864 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1865 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1866 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1867 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1868 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1869 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1870 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1871 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1872 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1874 - ring1 10GE-ports x710-4p10GE on SUTs:
1875 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1876 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1877 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1878 - ring2 10GE-ports x710-4p10GE on SUT:
1879 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1880 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1881 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1882 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1883 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1884 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1885 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1886 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1887 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1888 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1889 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1890 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1891 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1892 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1895 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1901 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1905 - ring1 10GE-ports x520-2p10GE on SUTs:
1906 - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1907 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1908 - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1909 - ring2 25GE-ports cx4-2p25GE on SUTs:
1910 - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1911 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1912 - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1915 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1919 - ring1 10GE-ports x553 copper port on SUTs:
1920 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1921 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1922 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1923 - ring2 10GE-ports x553 fiber port on SUTs:
1924 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1925 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1926 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1934 1. Ixia PerfectStorm One Appliance
1936 - Chassis: PS10GE4NG.
1937 - Motherboard: SuperMicro X11DPG-QT.
1938 - Processors: Quad-Core, Intel Processor.
1939 - HW accelerators: FPGA offload.
1941 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1942 - Physical Interfaces: 4 * 10GE SFP+.
1943 - Operating System: Native IxOS.
1949 1. Arm Cortex A-72 servers
1950 - 2 * ThunderX2 (VPP Device)
1951 - Chassis: GIGABYTE Rack Mount
1952 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1953 - RAM Memory: 16* 16GB DIMM
1954 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1955 - 1 * ThunderX2 (Performance)
1956 - Chassis: GIGABYTE Rack Mount
1957 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1958 - RAM Memory: 4* 32GB RDIMM
1959 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1960 - 2 * Huawei TaiShan 2280.
1961 - Chassis: Huawei TaiShan 2280.
1962 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1963 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1964 - Disks: 1* 4TB SATA HDD.
1967 ### Xeon and Atom Servers
1970 1. Intel Xeon servers:
1971 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1972 - Chassis: SuperMicro SYS-7049GP-TRT.
1973 - Motherboard: SuperMicro X11DPG-QT.
1974 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1975 - RAM Memory: 16* 16GB DDR4-2666MHz.
1976 - Disks: 2* 1.6TB 6G SATA SSD.
1977 2. Intel Atom servers with Rangely processors.
1978 - 3 * Netgate XG-2758-1u
1979 - Chassis: Netgate XG-2758-1u
1980 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1981 - RAM Memory: 16GB ECC
1985 ### Network Interface Cards
1989 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1990 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1991 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1993 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1995 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1997 - 4 * mcx556a-edat NICs (not on site yet, in transit)
2000 ### Pluggables and Cables
2006 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
2007 - 80 * 10G SR optic (generic, "Intel" compatible branded)
2013 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
2024 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable