1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
74 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
75 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
76 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
77 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
78 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
79 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
80 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
84 13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
85 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
86 Totals: 22 35 18 12 19 1 2 3 1 2 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
156 ### 3-Node-MACCHIATObin Arm Marvell
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
163 ### 3-Node-Rangeley Atom Testbeds
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
174 For management purposes, each server must have following two ports
175 connected to the management network:
179 - IPMI - Intelligent Platform Management Interface.
180 - Required for access to embedded server management with WebUI, CLI,
181 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183 - hostOS management port for general system management.
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
193 - Subnet: 10.30.50.0/24
194 - Gateway: 10.30.50.1
195 - Broadcast: 10.30.50.255
196 - DNS1: 199.204.44.24
197 - DNS2: 199.204.47.54
199 - Subnet: 10.30.51.0/24
200 - Gateway: 10.30.51.1
201 - Broadcast: 10.30.51.255
202 - DNS1: 199.204.44.24
203 - DNS2: 199.204.47.54
206 To access these hosts, VPN connection is required.
208 ### LOM (IPMI) VLAN IP Addresses
211 ------------ | -------
214 10.30.50.2 | LF Reserved
215 10.30.50.3 | LF Reserved
216 10.30.50.4 | LF Reserved
217 10.30.50.5 | LF Reserved
218 10.30.50.6 | LF Reserved
219 10.30.50.7 | LF Reserved
220 10.30.50.8 | LF Reserved
221 10.30.50.9 | LF Reserved
222 10.30.50.10 | LF Reserved
223 10.30.50.11 | LF Reserved
224 10.30.50.12 | LF Reserved
225 10.30.50.13 | LF Reserved
226 10.30.50.14 | LF Reserved
227 10.30.50.15 | LF Reserved
229 10.30.50.17 | t1-sut1
230 10.30.50.18 | t1-sut2
232 10.30.50.21 | t2-sut1
233 10.30.50.22 | t2-sut2
235 10.30.50.25 | t3-sut1
236 10.30.50.26 | t3-sut-2
237 10.30.50.28 | t4-sut1
238 10.30.50.29 | t4-sut2
239 10.30.50.30 | t4-sut3
240 10.30.50.36 | s17-t33-sut1
241 10.30.50.37 | s18-t33-sut2
242 10.30.50.41 | s3-t21-sut1
243 10.30.50.42 | s4-t21-tg1
244 10.30.50.43 | s11-t31-sut1
245 10.30.50.44 | s12-t31-sut2
246 10.30.50.45 | s13-t31-tg1
247 10.30.50.46 | s19-t33t34-tg1
248 10.30.50.47 | s1-t11-sut1
249 10.30.50.48 | s2-t12-sut1
250 10.30.50.49 | s5-t22-sut1
251 10.30.50.50 | s6-t22-tg1
252 10.30.50.51 | s7-t23-sut1
253 10.30.50.52 | s8-t23-tg1
254 10.30.50.53 | s9-t24-sut1
255 10.30.50.54 | s10-t24-tg1
256 10.30.50.55 | s14-t32-sut1
257 10.30.50.56 | s15-t32-sut2
258 10.30.50.57 | s16-t32-tg1
259 10.30.50.58 | s25-t25-sut1
260 10.30.50.59 | s26-t25-tg1
261 10.30.50.69 | s27-t13-sut
264 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0
265 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1
266 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2
267 10.30.55.10 | s28-t26t35-tg1
268 10.30.55.11 | s29-t26-sut1
269 10.30.55.12 | s30-t35-sut1
270 10.30.55.13 | s31-t35-sut2
271 10.30.50.255 | Broadcast
272 x.x.x.x | s32-t14-sut1
273 x.x.x.x | s33-t27-sut1
274 x.x.x.x | s34-t27-tg1
275 x.x.x.x | s35-t28-sut1
276 x.x.x.x | s36-t28-tg1
277 x.x.x.x | s37-t29-sut1
278 x.x.x.x | s38-t29-tg1
280 ### Management VLAN IP Addresses
283 ------------------------- | -------
286 10.30.51.2 | LF Reserved
287 10.30.51.3 | LF Reserved
288 10.30.51.4 | LF Reserved
289 10.30.51.5 | LF Reserved
290 10.30.51.6 | LF Reserved
291 10.30.51.7 | LF Reserved
292 10.30.51.8 | LF Reserved
293 10.30.51.9 | s22-t35-sut1 (netgate-1)
294 10.30.51.10 | s23-t35-sut2 (netgate-2)
295 10.30.51.11 | s24-t35-sut3 (netgate-3)
296 10.30.51.12 | softiron-1
297 10.30.51.13 | softiron-2
298 10.30.51.14 | softiron-3
299 10.30.51.15 | LF Reserved
301 10.30.51.17 | t1-sut1
302 10.30.51.18 | t1-sut2
304 10.30.51.21 | t2-sut1
305 10.30.51.22 | t2-sut2
307 10.30.51.25 | t3-sut1
308 10.30.51.26 | t3-sut-2
309 10.30.51.28 | t4-sut1
310 10.30.51.29 | t4-sut2
311 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
312 10.30.51.30 | t4-sut3
313 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
314 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
315 10.30.51.36 | s17-t33-sut1
316 10.30.51.37 | s18-t33-sut2
317 10.30.51.41 | s20-t34-sut1
318 10.30.51.42 | s21-t34-sut2
319 10.30.51.44 | s3-t21-sut1
320 10.30.51.45 | s4-t21-tg1
321 10.30.51.46 | s11-t31-sut1
322 10.30.51.47 | s12-t31-sut2
323 10.30.51.48 | s13-t31-tg1
324 10.30.51.49 | s19-t33t34-tg1
325 10.30.51.50 | s1-t11-sut1
326 10.30.51.51 | s2-t12-sut1
327 10.30.51.52 | s5-t22-sut1
328 10.30.51.53 | s6-t22-tg1
329 10.30.51.54 | s7-t23-sut1
330 10.30.51.55 | s8-t23-tg1
331 10.30.51.56 | s9-t24-sut1
332 10.30.51.57 | s10-t24-tg1
333 10.30.51.58 | s14-t32-sut1
334 10.30.51.59 | s15-t32-sut2
335 10.30.51.60 | s16-t32-tg1
336 10.30.51.61 | s25-t25-sut1
337 10.30.51.62 | s26-t25-tg1
338 10.30.51.69 | s27-t13-sut1
339 10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED
340 10.30.51.106-10.30.51.180 | VIRL2
341 10.30.51.181-10.30.51.254 | VIRL3
342 10.30.51.255 | Broadcast
343 10.32.8.10 | s28-t26t35-tg1
344 10.32.8.11 | s29-t26-sut1
345 10.32.8.12 | s30-t35-sut1
346 10.32.8.13 | s31-t35-sut2
347 x.x.x.x | s32-t14-sut1
348 x.x.x.x | s33-t27-sut1
349 x.x.x.x | s34-t27-tg1
350 x.x.x.x | s35-t28-sut1
351 x.x.x.x | s36-t28-tg1
352 x.x.x.x | s37-t29-sut1
353 x.x.x.x | s38-t29-tg1
355 ## Server Specifications
359 FD.io CSIT lab contains following server types:
361 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
362 - Quantity: 6 servers.
363 - Physical connectivity:
364 - CIMC and host management ports.
365 - NIC ports connected in 3-node topologies.
366 - Main HW configuration:
367 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
368 - Processors: 2* E5-2699v3 2.3 GHz.
369 - RAM Memory: 16* 32GB DDR4-2133MHz.
370 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
371 - NICs configuration:
372 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
373 - PCIe Slot1: Cisco VIC 1385 2p40GE.
374 - PCIe Slot2: Intel NIC x520 2p10GE.
376 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
377 - PCIe Slot4: Intel NIC xl710 2p40GE.
378 - PCIe Slot5: Intel NIC x710 2p10GE.
379 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
380 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
381 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
382 - Quantity: 3 servers.
383 - Physical connectivity:
384 - CIMC and host management ports.
385 - NIC ports connected in 3-node topologies.
386 - Main HW configuration:
387 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
388 - Processors: 2* E5-2699v3 2.3 GHz.
389 - RAM Memory: 16* 32GB DDR4-2133MHz.
390 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
391 - NICs configuration:
392 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
393 - PCIe Slot1: Intel NIC xl710 2p40GE.
394 - PCIe Slot2: Intel NIC x710 2p10GE.
395 - PCIe Slot3: Intel NIC x710 2p10GE.
396 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
397 - PCIe Slot4: Intel NIC xl710 2p40GE.
398 - PCIe Slot5: Intel NIC x710 2p10GE.
399 - PCIe Slot6: Intel NIC x710 2p10GE.
401 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
402 - Quantity: 3 servers.
403 - Physical connectivity:
404 - CIMC and host management ports.
405 - no NIC ports, standalone setup.
406 - Main HW configuration:
407 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
408 - Processors: 2* E5-2699v3 2.3 GHz.
409 - RAM Memory: 16* 32GB DDR4-2133MHz.
410 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
411 - NICs configuration:
412 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
414 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
417 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
419 - Physical connectivity:
420 - IPMI and host management ports.
421 - NIC ports connected into 2-node and 3-node topologies.
422 - Main HW configuration:
423 - Chassis: SuperMicro SYS-7049GP-TRT.
424 - Motherboard: SuperMicro X11DPG-QT.
425 - Processors: 2* Intel Platinum 8180 2.5 GHz.
426 - RAM Memory: 16* 16GB DDR4-2666MHz.
427 - Disks: 2* 1.6TB 6G SATA SSD.
428 - NICs configuration:
429 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
430 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
431 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
432 - PCIe Slot9 5e:00.xx: empty.
433 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
434 - PCIe Slot6 86:00.xx: empty.
435 - PCIe Slot8 af:00.xx: empty.
436 - PCIe Slot10 d8:00.xx: empty.
437 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
439 - Physical connectivity:
440 - IPMI and host management ports.
441 - NIC ports connected into 2-node and 3-node topologies.
442 - Main HW configuration:
443 - Chassis: SuperMicro SYS-7049GP-TRT.
444 - Motherboard: SuperMicro X11DPG-QT.
445 - Processors: 2* Intel Platinum 8180 2.5 GHz.
446 - RAM Memory: 16* 16GB DDR4-2666MHz.
447 - Disks: 2* 1.6TB 6G SATA SSD.
448 - NICs configuration:
449 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
450 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
451 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
452 - PCIe Slot9 5e:00.xx: empty.
453 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
454 - PCIe Slot6 86:00.xx: empty.
455 - PCIe Slot8 af:00.xx: empty.
456 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
457 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
459 - Physical connectivity:
460 - IPMI(?) and host management ports.
461 - NIC ports connected into 3-node topology.
462 - Main HW configuration:
463 - Chassis: Huawei TaiShan 2280.
464 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
465 - RAM Memory: 8* 16GB DDR4-2400MT/s
466 - Disks: 1* 4TB SATA HDD
467 - NICs configuration:
468 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
469 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
470 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
472 - Physical connectivity:
473 - Host management ports.
474 - NIC ports connected into 2-node and 3-node topologies.
475 - Main HW configuration:
476 - Chassis: MACCHIATObin.
477 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
478 - RAM Memory: 1* 16GB DDR4
479 - Disks: 1* 128GB(?) SATA SDD
480 - NICs configuration:
481 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
482 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
483 - Quantity: TBD based on testbed allocation.
484 - Physical connectivity:
485 - Management: serial Port (usb) for console
486 - NIC ports connected into 2-node.
487 - Main HW configuration:
488 - Chassis: Netgate XG-2758-1u
489 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
490 - RAM Memory: 16GB ECC
492 - NICs configuration:
493 - 2x 10Gb Intel 82599ES
495 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
497 - Physical connectivity:
498 - IPMI and host management ports.
499 - NIC ports connected into 2-node and 3-node topologies.
500 - Main HW configuration:
501 - Chassis: SuperMicro SYS-7049GP-TRT.
502 - Motherboard: SuperMicro X11DPG-QT.
503 - Processors: 2* Intel Platinum 8180 2.5 GHz.
504 - RAM Memory: 16* 16GB DDR4-2666MHz.
505 - Disks: 2* 1.6TB 6G SATA SSD.
506 - NICs configuration:
507 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
508 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
509 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
510 - PCIe Slot9 5e:00.xx: empty.
511 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
512 - PCIe Slot6 86:00.xx: empty.
513 - PCIe Slot8 af:00.xx: empty.
514 - PCIe Slot10 d8:00.xx: empty.
515 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
517 - Physical connectivity:
518 - Host management interface: 10/100/1000-BaseT.
519 - 8-port 10GE SFP+ integrated NIC.
520 - Main HW configuration:
521 - Chassis: PS10GE4NG.
522 - Motherboard: SuperMicro X11DPG-QT.
523 - Processors: Quad-Core, Intel Processor.
524 - HW accelerators: FPGA offload.
526 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
527 - Physical Interfaces: 4 * 10GE SFP+.
528 - Operating System: Native IxOS.
529 - Interface configuration:
534 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
536 - Physical connectivity:
537 - IPMI and host management ports.
539 - Main HW configuration:
540 - Chassis: SuperMicro SYS-7049GP-TRT.
541 - Motherboard: SuperMicro X11DPG-QT.
542 - Processors: 2* Intel Platinum 8180 2.5 GHz.
543 - RAM Memory: 16* 16GB DDR4-2666MHz.
544 - Disks: 2* 1.6TB 6G SATA SSD.
545 - NICs configuration:
546 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
547 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
548 - PCIe Slot4 3b:00.xx: empty.
549 - PCIe Slot9 5e:00.xx: empty.
550 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
551 - PCIe Slot6 86:00.xx: empty.
552 - PCIe Slot8 af:00.xx: empty.
553 - PCIe Slot10 d8:00.xx: empty.
554 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
556 - Physical connectivity:
557 - IPMI and host management ports.
558 - NIC ports connected into 1-node topologies.
559 - Main HW configuration:
560 - Chassis: Gigabyte R181-T90 1U
561 - Motheboard: MT91-FS1
562 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
563 - RAM Memory: 4* 32GB RDIMM
564 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
565 - NICs configuration:
567 - PCIe Slot1 05:00.xx: XL710-QDA2.
568 - PCIe Slot3 08:00.xx: XL710-QDA2.
570 - PCIe Slot6 85:00.xx: XL710-QDA2.
571 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
573 - Physical connectivity:
574 - IPMI and host management ports.
576 - Main HW configuration:
577 - Chassis: SuperMicro SYS-E300-9A
578 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
579 - RAM Memory: 32GB ECC
581 - NICs configuration:
582 - 2x 10Gb Intel x553 fiber ports
583 - 2x 10Gb Intel x553 copper ports
584 - 4x 1GB Intel I350 ports
586 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
588 - Physical connectivity:
589 - IPMI and host management ports.
590 - NIC ports connected into 1-node testbed topologies.
591 - Main HW configuration:
592 - Chassis: SuperMicro SYS-7049GP-TRT.
593 - Motherboard: SuperMicro X11DPG-QT.
594 - Processors: 2* Intel Platinum 8280 2.7 GHz.
595 - RAM Memory: 12* 16GB DDR4-2933.
596 - Disks: 2* 1.92TB SATA SSD.
597 - NICs configuration:
598 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
599 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
600 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
601 - PCIe Slot9 5e:00.xx: empty.
602 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
603 - PCIe Slot6 86:00.xx: empty.
604 - PCIe Slot8 af:00.xx: empty.
605 - PCIe Slot10 d8:00.xx: empty.
607 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
609 - Physical connectivity:
610 - IPMI and host management ports.
611 - NIC ports connected into 2-node testbed topologies.
612 - Main HW configuration:
613 - Chassis: SuperMicro SYS-7049GP-TRT.
614 - Motherboard: SuperMicro X11DPG-QT.
615 - Processors: 2* Intel Gold 6252N 2.3 GHz.
616 - RAM Memory: 12* 16GB DDR4-2933.
617 - Disks: 2* 1.92TB SATA SSD.
618 - NICs configuration:
619 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
620 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
621 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
622 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
623 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
624 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
625 - PCIe Slot6 86:00.xx: empty.
626 - PCIe Slot8 af:00.xx: empty.
627 - PCIe Slot10 d8:00.xx: empty.
628 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
630 - Physical connectivity:
631 - IPMI and host management ports.
632 - NIC ports connected into 2-node testbed topologies.
633 - Main HW configuration:
634 - Chassis: SuperMicro SYS-7049GP-TRT.
635 - Motherboard: SuperMicro X11DPG-QT.
636 - Processors: 2* Intel Platinum 8280 2.7 GHz.
637 - RAM Memory: 12* 16GB DDR4-2933.
638 - Disks: 2* 1.92TB SATA SSD.
639 - NICs configuration:
640 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
641 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
642 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
643 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
644 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
645 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
646 - PCIe Slot6 86:00.xx: empty.
647 - PCIe Slot8 af:00.xx: empty.
648 - PCIe Slot10 d8:00.xx: empty.
650 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
652 - Physical connectivity:
653 - CIMC and host management ports.
654 - no NIC ports, standalone setup.
655 - Main HW configuration:
656 - Chassis: SuperMicro 1029P-WTRT.
657 - Motherboard: SuperMicro X11DDW-NT.
658 - Processors: 2* Intel Platinum 8280 2.7 GHz.
659 - RAM Memory: 12* 16GB DDR4-2933.
660 - Disks: 4* 1.92TB SATA SSD.
661 - NICs configuration:
668 ### Naming Convention
670 Following naming convention is used within this page to specify physical
671 connectivity and wiring across defined CSIT testbeds:
674 - testbedname: testbedN.
676 - traffic-generator: tN-tgW.
677 - system-under-testX: tN-sutX.
682 - N - testbed number.
683 - tgW - server acts as traffic-generator with W index.
684 - sutX - server acts as system-under-test with X index.
685 - Y - PCIe slot number denoting a NIC card number within the host.
686 - Z - port number on the NIC card.
689 ## Testbeds Configuration
691 ### Per Testbed Server Allocation and Naming
693 #### 1-Node-Skylake Servers (1n-skx) PROD
696 - SUT [Server-Type-B6]:
697 - testbedname: testbed11.
698 - hostname: s1-t11-sut1.
699 - IPMI IP: 10.30.50.47
700 - Host IP: 10.30.51.50
702 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
703 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
704 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
705 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
706 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
707 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
708 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
709 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
710 - SUT [Server-Type-B6]:
711 - testbedname: testbed12.
712 - hostname: s2-t12-sut1.
713 - IPMI IP: 10.30.50.48
714 - Host IP: 10.30.51.51
716 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
717 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
718 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
719 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
720 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
721 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
722 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
723 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
726 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
729 - SUT [Server-Type-B9]:
730 - testbedname: testbed13.
731 - hostname: s27-t13-sut1.
732 - IPMI IP: 10.30.50.69
733 - Host IP: 10.30.51.69
735 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
736 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
737 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
738 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
739 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
740 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
743 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
746 - SUT [Server-Type-C1]:
747 - testbedname: testbed11.
748 - hostname: s32-t14-sut1.
752 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
753 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
754 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
755 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
756 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
757 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
758 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
759 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
762 #### 2-Node-Skylake Servers (2n-skx) PROD
765 - SUT [Server-Type-B1]:
766 - testbedname: testbed21.
767 - hostname: s3-t21-sut1.
768 - IPMI IP: 10.30.50.41
769 - Host IP: 10.30.51.44
771 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
772 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
773 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
774 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
775 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
776 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
777 - TG [Server-Type-B2]:
778 - testbedname: testbed21.
779 - hostname: s4-t21-tg1.
780 - IPMI IP: 10.30.50.42
781 - Host IP: 10.30.51.45
783 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
784 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
785 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
786 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
787 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
788 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
789 - SUT [Server-Type-B1]:
790 - testbedname: testbed22.
791 - hostname: s5-t22-sut1.
792 - IPMI IP: 10.30.50.49
793 - Host IP: 10.30.51.52
795 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
796 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
797 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
798 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
799 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
800 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
801 - TG [Server-Type-B2]:
802 - testbedname: testbed22.
803 - hostname: s6-t22-tg1.
804 - IPMI IP: 10.30.50.50
805 - Host IP: 10.30.51.53
807 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
808 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
809 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
810 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
811 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
812 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
813 - SUT [Server-Type-B1]:
814 - testbedname: testbed23.
815 - hostname: s7-t23-sut1.
816 - IPMI IP: 10.30.50.51
817 - Host IP: 10.30.51.54
819 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
820 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
821 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
822 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
823 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
824 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
825 - TG [Server-Type-B2]:
826 - testbedname: testbed23.
827 - hostname: s8-t23-tg1.
828 - IPMI IP: 10.30.50.52
829 - Host IP: 10.30.51.55
831 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
832 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
833 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
834 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
835 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
836 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
837 - SUT [Server-Type-B1]:
838 - testbedname: testbed24.
839 - hostname: s9-t24-sut1.
840 - IPMI IP: 10.30.50.53
841 - Host IP: 10.30.51.56
843 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
844 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
845 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
846 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
847 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
848 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
849 - TG [Server-Type-B2]:
850 - testbedname: testbed24.
851 - hostname: s10-t24-tg1.
852 - IPMI IP: 10.30.50.54
853 - Host IP: 10.30.51.57
855 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
856 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
857 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
858 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
859 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
860 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
863 #### 2-Node-Denverton Servers (2n-dnv) WIP
865 Note: ServerB28 (TG) is shared between testbed26 & testbed35
868 - TG [Server-Type-B2]:
869 - testbednames: testbed26 and testbed35.
870 - hostname: s28-t26t35-tg1.
871 - IPMI IP: 10.30.55.10
872 - Host IP: 10.32.8.10
874 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
875 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
876 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
877 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
878 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
879 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
880 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
881 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
882 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
883 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
884 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
885 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
886 - SUT [Server-Type-B10]:
887 - testbednames: testbed26.
888 - hostname: s29-t26-sut1.
889 - IPMI IP: 10.30.55.11
890 - Host IP: 10.32.8.11
892 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
893 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
894 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
895 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
898 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
901 - SUT [Server-Type-B8]:
902 - testbedname: testbed25.
903 - hostname: s25-t25-sut1.
904 - IPMI IP: 10.30.50.58
905 - Host IP: 10.30.51.61
907 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
908 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
909 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
910 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
911 - TG [Server-Type-B7]:
912 - testbedname: testbed25.
913 - hostname: s26-t25-tg1.
914 - IPMI IP: 10.30.50.59
915 - Host IP: 10.30.51.62
917 - s26-t25-tg1-p1 - 10GE-port1.
918 - s26-t25-tg1-p2 - 10GE-port2.
919 - s26-t25-tg1-p3 - 10GE-port3.
920 - s26-t25-tg1-p4 - 10GE-port4.
923 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
926 - SUT [Server-Type-C2]:
927 - testbedname: testbed27.
928 - hostname: s33-t27-sut1.
932 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
933 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
934 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
935 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
936 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
937 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
938 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
939 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
940 - TG [Server-Type-C3]:
941 - testbedname: testbed27.
942 - hostname: s34-t27-tg1.
946 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
947 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
948 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
949 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
950 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
951 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
952 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
953 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
954 - SUT [Server-Type-C2]:
955 - testbedname: testbed28.
956 - hostname: s35-t28-sut1.
960 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
961 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
962 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
963 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
964 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
965 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
966 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
967 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
968 - TG [Server-Type-C3]:
969 - testbedname: testbed28.
970 - hostname: s36-t28-tg1.
974 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
975 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
976 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
977 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
978 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
979 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
980 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
981 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
982 - SUT [Server-Type-C2]:
983 - testbedname: testbed29.
984 - hostname: s37-t29-sut1.
988 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
989 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
990 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
991 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
992 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
993 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
994 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
995 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
996 - TG [Server-Type-C3]:
997 - testbedname: testbed29.
998 - hostname: s38-t29-tg1.
1002 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1003 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1004 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1005 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1006 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1007 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1008 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1009 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1012 #### 3-Node-Haswell Servers (3n-hsw) PROD
1015 1. SUT [Server-Type-A1]:
1016 - testbedname: testbed1.
1017 - hostname: t1-sut1.
1018 - CIMC IP: 10.30.50.17
1019 - Host IP: 10.30.51.17
1021 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1022 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1023 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1024 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1025 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1026 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1027 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1028 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1029 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1030 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1031 2. SUT [Server-Type-A1]:
1032 - testbedname: testbed1.
1033 - hostname: t1-sut2.
1034 - CIMC IP: 10.30.50.18
1035 - Host IP: 10.30.51.18
1037 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1038 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1039 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1040 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1041 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1042 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1043 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1044 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1045 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1046 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1047 3. TG [Server-Type-A2]:
1048 - testbedname: testbed1.
1050 - CIMC IP: 10.30.50.16
1051 - Host IP: 10.30.51.16
1053 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1054 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1055 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1056 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1057 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1058 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1059 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1060 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1061 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1062 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1063 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1064 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1065 4. SUT [Server-Type-A1]:
1066 - testbedname: testbed2.
1067 - hostname: t2-sut1.
1068 - CIMC IP: 10.30.50.21
1069 - Host IP: 10.30.51.21
1071 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1072 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1073 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1074 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1075 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1076 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1077 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1078 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1079 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1080 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1081 5. SUT [Server-Type-A1]:
1082 - testbedname: testbed2.
1083 - hostname: t2-sut2.
1084 - CIMC IP: 10.30.50.22
1085 - Host IP: 10.30.51.22
1087 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1088 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1089 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1090 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1091 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1092 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1093 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1094 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1095 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1096 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1097 6. TG [Server-Type-A2]:
1098 - testbedname: testbed2.
1100 - CIMC IP: 10.30.50.20
1101 - Host IP: 10.30.51.20
1103 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1104 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1105 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1106 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1107 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1108 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1109 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1110 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1111 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1112 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1113 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1114 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1115 7. SUT [Server-Type-A1]:
1116 - testbedname: testbed3.
1117 - hostname: t3-sut1.
1118 - CIMC IP: 10.30.50.25
1119 - Host IP: 10.30.51.25
1121 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1122 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1123 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1124 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1125 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1126 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1127 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1128 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1129 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1130 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1131 8. SUT [Server-Type-A1]:
1132 - testbedname: testbed3.
1133 - hostname: t3-sut2.
1134 - CIMC IP: 10.30.50.26
1135 - Host IP: 10.30.51.26
1137 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1138 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1139 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1140 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1141 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1142 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1143 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1144 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1145 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1146 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1147 9. TG [Server-Type-A2]:
1148 - testbedname: testbed3.
1150 - CIMC IP: 10.30.50.24
1151 - Host IP: 10.30.51.24
1153 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1154 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1155 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1156 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1157 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1158 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1159 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1160 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1161 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1162 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1163 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1164 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1167 #### 3-Node-Skylake Servers (3n-skx) PROD
1170 - ServerB11 [Server-Type-B1]:
1171 - testbedname: testbed31.
1172 - hostname: s11-t31-sut1.
1173 - IPMI IP: 10.30.50.43
1174 - Host IP: 10.30.51.46
1176 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1177 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1178 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1179 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1180 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1181 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1182 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1183 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1184 - ServerB12 [Server-Type-B1]:
1185 - testbedname: testbed31.
1186 - hostname: s12-t31-sut2.
1187 - IPMI IP: 10.30.50.44
1188 - Host IP: 10.30.51.47
1190 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1191 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1192 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1193 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1194 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1195 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1196 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1197 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1198 - ServerB13 [Server-Type-B2]:
1199 - testbedname: testbed31.
1200 - hostname: s13-t31-tg1.
1201 - IPMI IP: 10.30.50.45
1202 - Host IP: 10.30.51.48
1204 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1205 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1206 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1207 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1208 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1209 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1210 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1211 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1212 - ServerB14 [Server-Type-B1]:
1213 - testbedname: testbed32.
1214 - hostname: s14-t32-sut1.
1215 - IPMI IP: 10.30.50.55
1216 - Host IP: 10.30.51.58
1218 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1219 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1220 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1221 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1222 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1223 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1224 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1225 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1226 - ServerB15 [Server-Type-B1]:
1227 - testbedname: testbed32.
1228 - hostname: s15-t32-sut2.
1229 - IPMI IP: 10.30.50.56
1230 - Host IP: 10.30.51.59
1232 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1233 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1234 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1235 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1236 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1237 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1238 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1239 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1240 - ServerB16 [Server-Type-B2]:
1241 - testbedname: testbed32.
1242 - hostname: s16-t32-tg1.
1243 - IPMI IP: 10.30.50.57
1244 - Host IP: 10.30.51.60
1246 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1247 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1248 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1249 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1250 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1251 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1252 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1253 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1256 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1258 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1261 - ServerB22 [Server-Type-B5]:
1262 - testbedname: testbed35.
1263 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1264 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1265 - Host IP: 10.30.51.9
1267 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1268 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1270 - ServerB23 [Server-Type-B5]:
1271 - testbedname: testbed35.
1272 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1273 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1274 - Host IP: 10.30.51.10
1276 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1277 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1279 - ServerB24 [Server-Type-B5]:
1280 - testbedname: testbed35.
1281 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1282 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1283 - Host IP: 10.30.51.11
1285 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1286 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1290 #### 3-Node-Taishan Servers (3n-tsh) WIP
1292 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1295 - ServerB17 [Server-Type-B3]:
1296 - testbedname: testbed33.
1297 - hostname: s17-t33-sut1.
1298 - IPMI IP: 10.30.50.36
1299 - Host IP: 10.30.51.36
1301 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1302 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1303 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1304 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1305 - ServerB18 [Server-Type-B3]:
1306 - testbedname: testbed33.
1307 - hostname: s18-t33-sut2.
1308 - IPMI IP: 10.30.50.37
1309 - Host IP: 10.30.51.37
1311 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1312 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1313 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1314 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1315 - ServerB19 [Server-Type-B2]:
1316 - testbednames: testbed33 and testbed34.
1317 - hostname: s19-t33t34-tg1.
1318 - IPMI IP: 10.30.50.46
1319 - Host IP: 10.30.51.49
1321 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1322 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1323 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1324 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1325 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1326 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1327 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1328 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1329 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1330 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1331 - ServerB20 [Server-Type-B4]:
1332 - testbedname: testbed34.
1333 - hostname: s20-t34-sut1.
1335 - Host IP: 10.30.51.41
1337 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1338 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1339 - ServerB21 [Server-Type-B4]:
1340 - testbedname: testbed34.
1341 - hostname: s21-t34-sut2.
1343 - Host IP: 10.30.51.42
1345 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1346 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1349 #### 3-Node-Denverton Servers (3n-dnv) WIP
1352 - ServerB30 [Server-Type-B10]:
1353 - testbednames: testbed35.
1354 - hostname: s30-t35-sut1.
1355 - IPMI IP: 10.30.55.12
1356 - Host IP: 10.32.8.12
1358 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1359 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1360 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1361 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1362 - ServerB31 [Server-Type-B10]:
1363 - testbednames: testbed35.
1364 - hostname: s31-t35-sut2.
1365 - IPMI IP: 10.30.55.13
1366 - Host IP: 10.32.8.13
1368 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1369 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1370 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1371 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1374 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1380 ### Per Testbed Wiring
1382 #### 1-Node-Skylake Wiring (1n-skx) PROD
1386 - ring1 10GE-ports x710-4p10GE:
1387 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1388 - ring2 10GE-ports x710-4p10GE:
1389 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1390 - ring3 10GE-ports x710-4p10GE:
1391 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1392 - ring4 10GE-ports x710-4p10GE:
1393 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1395 - ring1 10GE-ports x710-4p10GE:
1396 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1397 - ring2 10GE-ports x710-4p10GE:
1398 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1399 - ring3 10GE-ports x710-4p10GE:
1400 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1401 - ring4 10GE-ports x710-4p10GE:
1402 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1405 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1409 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1410 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1411 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1412 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1413 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1414 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1417 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1421 - ring1 10GE-ports x710-4p10GE:
1422 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1423 - ring2 10GE-ports x710-4p10GE:
1424 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1425 - ring3 10GE-ports x710-4p10GE:
1426 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1427 - ring4 10GE-ports x710-4p10GE:
1428 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1431 #### 2-Node-Skylake Wiring (2n-skx) PROD
1435 - ring1 10GE-ports x710-4p10GE on SUT:
1436 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1437 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1438 - ring2 10GE-ports x710-4p10GE on SUT:
1439 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1440 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1441 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1442 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1443 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1445 - ring1 10GE-ports x710-4p10GE on SUT:
1446 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1447 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1448 - ring2 10GE-ports x710-4p10GE on SUT:
1449 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1450 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1451 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1452 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1453 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1455 - ring1 10GE-ports x710-4p10GE on SUT:
1456 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1457 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1458 - ring2 10GE-ports x710-4p10GE on SUT:
1459 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1460 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1461 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1462 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1463 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1465 - ring1 10GE-ports x710-4p10GE on SUT:
1466 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1467 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1468 - ring2 10GE-ports x710-4p10GE on SUT:
1469 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1470 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1471 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1472 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1473 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1476 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1480 - ring1 10GE-ports x553 copper port on SUT:
1481 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1482 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1483 - ring2 10GE-ports x553 fiber port on SUT:
1484 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1485 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1488 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1492 - link1 10GE-port x710-4p10GE on SUT:
1493 - t25-tg1-p1 to t25-sut1-c2/p1.
1494 - link2 10GE-port x710-4p10GE on SUT:
1495 - t25-tg1-p2 to t25-sut1-c2/p2.
1496 - link3 10GE-port x710-4p10GE on SUT:
1497 - t25-tg1-p3 to t25-sut1-c2/p3.
1498 - link4 10GE-port x710-4p10GE on SUT:
1499 - t25-tg1-p4 to t25-sut1-c2/p4.
1502 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1506 - ring1 10GE-ports x710-4p10GE on SUT:
1507 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1508 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1509 - ring2 10GE-ports x710-4p10GE on SUT:
1510 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1511 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1512 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1513 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1514 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1515 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1516 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1517 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1519 - ring1 10GE-ports x710-4p10GE on SUT:
1520 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1521 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1522 - ring2 10GE-ports x710-4p10GE on SUT:
1523 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1524 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1525 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1526 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1527 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1528 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1529 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1530 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1532 - ring1 10GE-ports x710-4p10GE on SUT:
1533 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1534 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1535 - ring2 10GE-ports x710-4p10GE on SUT:
1536 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1537 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1538 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1539 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1540 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1541 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1542 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1543 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1546 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1550 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1551 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1552 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1553 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1554 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1555 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1556 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1557 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1558 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1559 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1560 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1561 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1562 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1563 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1564 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1565 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1566 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1567 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1568 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1569 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1570 - TG loopback ports Intel NIC x710 2p10GE
1571 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1574 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1575 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1576 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1577 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1578 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1579 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1580 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1581 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1582 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1583 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1584 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1585 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1586 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1587 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1588 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1589 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1590 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1591 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1592 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1593 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1594 - TG loopback ports Intel NIC x710 2p10GE
1595 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1598 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1599 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1600 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1601 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1602 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1603 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1604 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1605 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1606 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1607 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1608 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1609 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1610 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1611 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1612 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1613 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1614 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1615 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1616 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1617 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1618 - TG loopback ports Intel NIC x710 2p10GE
1619 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1622 #### 3-Node-Skylake Wiring (3n-skx) PROD
1626 - ring1 10GE-ports x710-4p10GE on SUTs:
1627 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1628 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1629 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1630 - ring2 10GE-ports x710-4p10GE on SUT:
1631 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1632 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1633 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1634 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1635 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1636 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1637 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1638 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1639 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1640 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1641 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1642 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1643 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1644 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1646 - ring1 10GE-ports x710-4p10GE on SUTs:
1647 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1648 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1649 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1650 - ring2 10GE-ports x710-4p10GE on SUT:
1651 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1652 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1653 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1654 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1655 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1656 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1657 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1658 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1659 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1660 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1661 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1662 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1663 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1664 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1667 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1673 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1677 - ring1 10GE-ports x520-2p10GE on SUTs:
1678 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1679 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1680 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1681 - ring2 25GE-ports cx4-2p25GE on SUTs:
1682 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1683 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1684 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1687 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1691 - ring1 10GE-ports Marvell on SUTs:
1692 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1693 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1694 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1697 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1701 - ring1 10GE-ports x553 copper port on SUTs:
1702 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1703 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1704 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1705 - ring2 10GE-ports x553 fiber port on SUTs:
1706 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1707 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1708 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1716 1. Ixia PerfectStorm One Appliance
1718 - Chassis: PS10GE4NG.
1719 - Motherboard: SuperMicro X11DPG-QT.
1720 - Processors: Quad-Core, Intel Processor.
1721 - HW accelerators: FPGA offload.
1723 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1724 - Physical Interfaces: 4 * 10GE SFP+.
1725 - Operating System: Native IxOS.
1731 1. Arm Cortex A-72 servers
1733 - Chassis: Marvell ThunderX2
1734 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1735 - RAM Memory: 4* 32GB RDIMM
1736 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1737 - 2 * Huawei TaiShan 2280.
1738 - Chassis: Huawei TaiShan 2280.
1739 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1740 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1741 - Disks: 1* 4TB SATA HDD.
1743 - Chassis: MACCHIATObin.
1744 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1745 - RAM Memory: 1* 16GB DDR4.
1746 - Disks: 1* 128GB(?) SATA SDD.
1749 ### Xeon and Atom Servers
1752 1. Intel Xeon servers:
1753 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1754 - Chassis: SuperMicro SYS-7049GP-TRT.
1755 - Motherboard: SuperMicro X11DPG-QT.
1756 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1757 - RAM Memory: 16* 16GB DDR4-2666MHz.
1758 - Disks: 2* 1.6TB 6G SATA SSD.
1759 2. Intel Atom servers with Rangely processors.
1760 - 3 * Netgate XG-2758-1u
1761 - Chassis: Netgate XG-2758-1u
1762 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1763 - RAM Memory: 16GB ECC
1767 ### Network Interface Cards
1771 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1772 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1773 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1775 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1777 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1779 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1782 ### Pluggables and Cables
1788 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1789 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1795 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1806 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable