1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
10 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
11 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
12 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
13 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
14 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
17 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
18 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
33 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
34 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
35 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
36 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
39 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
40 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
41 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
54 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
55 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr
75 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0
76 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0
77 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 2 0 0 0 0 0 0
78 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 0 0
79 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 2 0 0 0 0
80 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0
81 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 0 0 0 0 0 0 0
82 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0
83 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 0 0
84 10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 1 0 0 0 0 0 0
85 11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 8 0
86 12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0
87 13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0
88 14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 2 0 0 0 0 0
89 15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 2 0 0 1 0
90 17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2 0 0
91 18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 6 0
92 19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 .5 2
93 Totals: 32 41 20.5 4 17 1 2 3 2 4 7 2 15.5 2
96 ### 1-Node-Skylake Xeon Intel (1n-skx)
98 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
99 ports connected back-to-back ([Server Types](#server-types)).
100 Used for FD.io VPP_Device functional driver tests.
102 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
104 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
105 ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
110 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
111 NIC ports connected back-to-back ([Server Types](#server-types)).
113 Used for FD.io VPP_Device functional driver tests.
115 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
117 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
118 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
119 circular topology ([Server Types](#server-types)).
120 Used for FD.io TCP/IP and HTTP performance tests.
122 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
124 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
125 one TG (Server-Type-C3) connected in a 2-node circular topology
126 ([Server Types](#server-types)).
127 Used for FD.io performance tests.
129 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
131 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
132 one TG (Server-Type-D2) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
138 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
139 one TG (Server-Type-E31) connected in a 2-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 2-Node-Icelake Xeon Intel (2n-icx)
145 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
146 one TG (Server-Type-F2) connected in a 2-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
150 ### 3-Node-Haswell Xeon Intel (3n-hsw)
152 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
153 TG (Server-Type-A2) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
157 ### 3-Node-Rangeley Atom Testbeds
159 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
160 TG (Server-Type-2) connected in a 3-node circular topology
161 ([Server Types](#server-types)).
162 Used for FD.io performance tests.
164 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
166 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
167 TG (Server-Type-E31) connected in a 3-node circular topology
168 ([Server Types](#server-types)).
169 Used for FD.io performance tests.
171 ### 3-Node-Altra Arm Ampere (3n-alt)
173 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
174 TG (Server-Type-F4) connected in a 3-node circular topology
175 ([Server Types](#server-types)).
176 Used for FD.io performance tests.
178 ### 3-Node-Icelake Xeon Intel (3n-icx)
180 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
181 TG (Server-Type-F3) connected in a 3-node circular topology
182 ([Server Types](#server-types)).
183 Used for FD.io performance tests.
185 ### 3-Node-SnowRidge Atom Intel (3n-snr)
187 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
188 TG (Server-Type-F4) connected in a 3-node circular topology
189 ([Server Types](#server-types)).
190 Used for FD.io performance tests.
197 For management purposes, each server must have following two ports
198 connected to the management network:
202 - IPMI - Intelligent Platform Management Interface.
203 - Required for access to embedded server management with WebUI, CLI,
204 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
205 - 1GE/10GE/40GE management port
206 - hostOS management port for general system management.
211 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
212 Management port, which are connected to two different VLANs.
216 - Subnet: 10.30.50.0/24
217 - Gateway: 10.30.50.1
218 - Broadcast: 10.30.50.255
219 - DNS1: 199.204.44.24
220 - DNS2: 199.204.47.54
222 - Subnet: 10.30.51.0/24
223 - Gateway: 10.30.51.1
224 - Broadcast: 10.30.51.255
225 - DNS1: 199.204.44.24
226 - DNS2: 199.204.47.54
229 To access these hosts, VPN connection is required.
231 ### LOM (IPMI) VLAN IP Addresses
234 ------------ | -------
237 10.30.50.2 | LF Reserved
238 10.30.50.3 | LF Reserved
239 10.30.50.4 | LF Reserved
240 10.30.50.5 | LF Reserved
241 10.30.50.6 | LF Reserved
242 10.30.50.7 | LF Reserved
243 10.30.50.8 | LF Reserved
244 10.30.50.9 | LF Reserved
245 10.30.50.10 | LF Reserved
246 10.30.50.11 | LF Reserved
247 10.30.50.12 | LF Reserved
248 10.30.50.13 | LF Reserved
249 10.30.50.14 | LF Reserved
250 10.30.50.15 | LF Reserved
251 10.30.50.16 | s16-nomad
252 10.30.50.17 | s17-nomad
253 10.30.50.18 | s18-nomad
254 10.30.50.19 | s19-nomad
255 10.30.50.20 | s20-nomad
256 10.30.50.21 | s21-nomad
257 10.30.50.22 | s22-nomad
258 10.30.50.23 | s23-nomad
259 10.30.50.24 | s24-nomad
260 10.30.50.25 | s25-nomad
261 10.30.50.26 | s26-nomad
262 10.30.50.36 | s17-t33-sut1
263 10.30.50.37 | s18-t33-sut2
264 10.30.50.38 | fdio-marvell-dev
265 10.30.50.41 | s3-t21-sut1
266 10.30.50.42 | s4-t21-tg1
267 10.30.50.43 | s11-t31-sut1
268 10.30.50.44 | s12-t31-sut2
269 10.30.50.45 | s13-t31-tg1
270 10.30.50.46 | s19-t33t211-tg1
271 10.30.50.47 | s1-t11-sut1
272 10.30.50.48 | s2-t12-sut1
273 10.30.50.49 | s5-t22-sut1
274 10.30.50.50 | s6-t22-tg1
275 10.30.50.51 | s7-t23-sut1
276 10.30.50.52 | s8-t23-tg1
277 10.30.50.53 | s9-t24-sut1
278 10.30.50.54 | s10-t24-tg1
279 10.30.50.55 | s14-t32-sut1
280 10.30.50.56 | s15-t32-sut2
281 10.30.50.57 | s16-t32-tg1
282 10.30.50.58 | s25-t25-sut1
283 10.30.50.59 | s26-t25-tg1
284 10.30.50.69 | s27-t211-sut1
285 10.30.50.70 | s55-t13-sut1
286 10.30.50.71 | s56-t14-sut1
287 10.30.50.72 | s62-t34-sut1
288 10.30.50.73 | s63-t34-sut2
289 10.30.50.74 | s64-t34-tg1
290 10.30.50.75 | s65-t37-sut1
291 10.30.50.76 | s66-t37-sut2
292 10.30.50.77 | s67-t37-tg1
293 10.30.50.78 | s78-t38-sut1
294 10.30.50.79 | s79-t38-sut2
295 10.30.50.80 | s80-t38-tg1
296 10.30.50.81 | s71-t212-sut1
297 10.30.50.82 | s72-t212-tg1
298 10.30.50.83 | s83-t213-sut1
299 10.30.50.84 | s84-t213-tg1
300 10.30.50.85 | s85-t214-sut1
301 10.30.50.86 | s86-t214-tg1
302 10.30.50.87 | s87-t215-sut1
303 10.30.50.88 | s88-t215-tg1
304 10.30.50.89 | s89-t39t310-tg1
305 10.30.50.90 | s90-t311t312-tg1
306 10.30.50.91 | s91-nomad
307 10.30.50.92 | s92-nomad
308 10.30.50.93 | s93-t39-sut1
309 10.30.50.94 | s94-t39-sut2
310 10.30.50.255 | Broadcast
313 10.30.55.10 | s28-t26t35-tg1
314 10.30.55.11 | s29-t26-sut1
315 10.30.55.12 | s30-t35-sut1
316 10.30.55.13 | s31-t35-sut2
317 10.30.55.18 | s33-t27-sut1
318 10.30.55.19 | s34-t27-tg1
319 10.30.55.20 | s35-t28-sut1
320 10.30.55.21 | s36-t28-tg1
321 10.30.55.22 | s37-t29-sut1
322 10.30.55.23 | s38-t29-tg1
323 10.30.55.24 | s60-t210-sut1
324 10.30.55.25 | s61-t210-tg1
325 10.30.55.255 | Broadcast
327 ### Management VLAN IP Addresses
330 -------------| -------
333 10.30.51.2 | LF Reserved
334 10.30.51.3 | LF Reserved
335 10.30.51.4 | LF Reserved
336 10.30.51.5 | LF Reserved
337 10.30.51.6 | LF Reserved
338 10.30.51.7 | LF Reserved
339 10.30.51.8 | LF Reserved
340 10.30.51.15 | LF Reserved
341 10.30.51.16 | s16-nomad
342 10.30.51.17 | s17-nomad
343 10.30.51.18 | s18-nomad
344 10.30.51.19 | s19-nomad
345 10.30.51.20 | s20-nomad
346 10.30.51.21 | s21-nomad
347 10.30.51.22 | s22-nomad
348 10.30.51.23 | s23-nomad
349 10.30.51.24 | s24-nomad
350 10.30.51.25 | s25-nomad
351 10.30.51.26 | s26-nomad
352 10.30.51.36 | s17-t33-sut1
353 10.30.51.37 | s18-t33-sut2
354 10.30.51.38 | fdio-marvell-dev
355 10.30.51.44 | s3-t21-sut1
356 10.30.51.45 | s4-t21-tg1
357 10.30.51.46 | s11-t31-sut1
358 10.30.51.47 | s12-t31-sut2
359 10.30.51.48 | s13-t31-tg1
360 10.30.51.49 | s19-t33t211-tg1
361 10.30.51.50 | s1-t11-sut1
362 10.30.51.51 | s2-t12-sut1
363 10.30.51.52 | s5-t22-sut1
364 10.30.51.53 | s6-t22-tg1
365 10.30.51.54 | s7-t23-sut1
366 10.30.51.55 | s8-t23-tg1
367 10.30.51.56 | s9-t24-sut1
368 10.30.51.57 | s10-t24-tg1
369 10.30.51.58 | s14-t32-sut1
370 10.30.51.59 | s15-t32-sut2
371 10.30.51.60 | s16-t32-tg1
372 10.30.51.61 | s25-t25-sut1
373 10.30.51.62 | s26-t25-tg1
374 10.30.51.69 | s27-t211-sut1
375 10.30.51.70 | s55-t13-sut1
376 10.30.51.71 | s56-t14-sut1
377 10.30.51.72 | s62-t34-sut1
378 10.30.51.73 | s63-t34-sut2
379 10.30.51.74 | s64-t34-tg1
380 10.30.51.75 | s65-t37-sut1
381 10.30.51.76 | s66-t37-sut2
382 10.30.51.77 | s67-t37-tg1
383 10.30.51.78 | s78-t38-sut1
384 10.30.51.79 | s79-t38-sut2
385 10.30.51.80 | s80-t38-tg1
386 10.30.51.81 | s71-t212-sut1
387 10.30.51.82 | s72-t212-tg1
388 10.30.51.83 | s83-t213-sut1
389 10.30.51.84 | s84-t213-tg1
390 10.30.51.85 | s85-t214-sut1
391 10.30.51.86 | s86-t214-tg1
392 10.30.51.87 | s87-t215-sut1
393 10.30.51.88 | s88-t215-tg1
394 10.30.51.89 | s89-t39t310-tg1
395 10.30.51.90 | s90-t311t312-tg1
396 10.30.51.91 | s91-nomad
397 10.30.51.92 | s92-nomad
398 10.30.51.93 | s93-t39-sut1
399 10.30.51.94 | s94-t39-sut2
400 10.30.51.255 | Broadcast
403 10.32.8.10 | s28-t26t35-tg1
404 10.32.8.11 | s29-t26-sut1
405 10.32.8.12 | s30-t35-sut1
406 10.32.8.13 | s31-t35-sut2
407 10.32.8.18 | s33-t27-sut1
408 10.32.8.19 | s34-t27-tg1
409 10.32.8.20 | s35-t28-sut1
410 10.32.8.21 | s36-t28-tg1
411 10.32.8.22 | s37-t29-sut1
412 10.32.8.23 | s38-t29-tg1
413 10.32.8.24 | s60-t210-sut1
414 10.32.8.25 | s61-t210-tg1
415 10.32.8.255 | Broadcast
417 ## Server Specifications
421 FD.io CSIT lab contains following server types:
423 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
424 - Quantity: 6 servers.
425 - Physical connectivity:
426 - CIMC and host management ports.
427 - NIC ports connected in 3-node topologies.
428 - Main HW configuration:
429 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
430 - Processors: 2* E5-2699v3 2.3 GHz.
431 - RAM Memory: 16* 32GB DDR4-2133MHz.
432 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
433 - NICs configuration:
434 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
438 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
442 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
443 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
444 - Quantity: 3 servers.
445 - Physical connectivity:
446 - CIMC and host management ports.
447 - NIC ports connected in 3-node topologies.
448 - Main HW configuration:
449 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
450 - Processors: 2* E5-2699v3 2.3 GHz.
451 - RAM Memory: 16* 32GB DDR4-2133MHz.
452 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
453 - NICs configuration:
454 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
458 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
463 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
464 - Quantity: 3 servers.
465 - Physical connectivity:
466 - CIMC and host management ports.
467 - no NIC ports, standalone setup.
468 - Main HW configuration:
469 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
470 - Processors: 2* E5-2699v3 2.3 GHz.
471 - RAM Memory: 16* 32GB DDR4-2133MHz.
472 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
473 - NICs configuration:
474 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
476 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
479 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
481 - Physical connectivity:
482 - IPMI and host management ports.
483 - NIC ports connected into 2-node and 3-node topologies.
484 - Main HW configuration:
485 - Chassis: SuperMicro SYS-7049GP-TRT.
486 - Motherboard: SuperMicro X11DPG-QT.
487 - Processors: 2* Intel Platinum 8180 2.5 GHz.
488 - RAM Memory: 16* 16GB DDR4-2666MHz.
489 - Disks: 2* 1.6TB 6G SATA SSD.
490 - NICs configuration:
491 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
492 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
493 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
494 - PCIe Slot9 5e:00.xx: empty.
495 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
496 - PCIe Slot6 86:00.xx: empty.
497 - PCIe Slot8 af:00.xx: empty.
498 - PCIe Slot10 d8:00.xx: empty.
499 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
501 - Physical connectivity:
502 - IPMI and host management ports.
503 - NIC ports connected into 2-node and 3-node topologies.
504 - Main HW configuration:
505 - Chassis: SuperMicro SYS-7049GP-TRT.
506 - Motherboard: SuperMicro X11DPG-QT.
507 - Processors: 2* Intel Platinum 8180 2.5 GHz.
508 - RAM Memory: 16* 16GB DDR4-2666MHz.
509 - Disks: 2* 1.6TB 6G SATA SSD.
510 - NICs configuration:
511 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
512 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
513 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
514 - PCIe Slot9 5e:00.xx: empty.
515 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
516 - PCIe Slot6 86:00.xx: empty.
517 - PCIe Slot8 af:00.xx: empty.
518 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
519 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
520 - Quantity: TBD based on testbed allocation.
521 - Physical connectivity:
522 - Management: serial Port (usb) for console
523 - NIC ports connected into 2-node.
524 - Main HW configuration:
525 - Chassis: Netgate XG-2758-1u
526 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
527 - RAM Memory: 16GB ECC
529 - NICs configuration:
530 - 2x 10Gb Intel 82599ES
532 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
534 - Physical connectivity:
535 - IPMI and host management ports.
536 - NIC ports connected into 1-node topologies.
537 - Main HW configuration:
538 - Chassis: SuperMicro SYS-7049GP-TRT.
539 - Motherboard: SuperMicro X11DPG-QT.
540 - Processors: 2* Intel Platinum 8180 2.5 GHz.
541 - RAM Memory: 16* 16GB DDR4-2666MHz.
542 - Disks: 2* 1.6TB 6G SATA SSD.
543 - NICs configuration:
544 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
545 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
546 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
547 - PCIe Slot9 5e:00.xx: empty.
548 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
549 - PCIe Slot6 86:00.xx: empty.
550 - PCIe Slot8 af:00.xx: empty.
551 - PCIe Slot10 d8:00.xx: empty.
552 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
554 - Physical connectivity:
555 - Host management interface: 10/100/1000-BaseT.
556 - 8-port 10GE SFP+ integrated NIC.
557 - Main HW configuration:
558 - Chassis: PS10GE4NG.
559 - Motherboard: SuperMicro X11DPG-QT.
560 - Processors: Quad-Core, Intel Processor.
561 - HW accelerators: FPGA offload.
563 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
564 - Physical Interfaces: 4 * 10GE SFP+.
565 - Operating System: Native IxOS.
566 - Interface configuration:
571 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
573 - Physical connectivity:
574 - IPMI and host management ports.
576 - Main HW configuration:
577 - Chassis: SuperMicro SYS-7049GP-TRT.
578 - Motherboard: SuperMicro X11DPG-QT.
579 - Processors: 2* Intel Platinum 8180 2.5 GHz.
580 - RAM Memory: 16* 16GB DDR4-2666MHz.
581 - Disks: 2* 1.6TB 6G SATA SSD.
582 - NICs configuration:
583 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
584 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
585 - PCIe Slot4 3b:00.xx: empty.
586 - PCIe Slot9 5e:00.xx: empty.
587 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
588 - PCIe Slot6 86:00.xx: empty.
589 - PCIe Slot8 af:00.xx: empty.
590 - PCIe Slot10 d8:00.xx: empty.
591 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
593 - Physical connectivity:
594 - IPMI and host management ports.
596 - Main HW configuration:
597 - Chassis: SuperMicro SYS-E300-9A
598 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
599 - RAM Memory: 32GB ECC
601 - NICs configuration:
602 - 2x 10Gb Intel x553 fiber ports
603 - 2x 10Gb Intel x553 copper ports
604 - 4x 1GB Intel I350 ports
605 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
607 - Physical connectivity:
608 - IPMI and host management ports.
609 - NIC ports connected into 1-node testbed topologies.
610 - Main HW configuration:
611 - Chassis: SuperMicro SYS-7049GP-TRT.
612 - Motherboard: SuperMicro X11DPG-QT.
613 - Processors: 2* Intel Platinum 8280 2.7 GHz.
614 - RAM Memory: 12* 16GB DDR4-2933.
615 - Disks: 2* 1.92TB SATA SSD.
616 - NICs configuration:
617 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
618 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
619 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
620 - PCIe Slot9 5e:00.xx: empty.
621 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
622 - PCIe Slot6 86:00.xx: empty.
623 - PCIe Slot8 af:00.xx: empty.
624 - PCIe Slot10 d8:00.xx: empty.
625 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
627 - Physical connectivity:
628 - IPMI and host management ports.
629 - NIC ports connected into 2-node testbed topologies.
630 - Main HW configuration:
631 - Chassis: SuperMicro SYS-7049GP-TRT.
632 - Motherboard: SuperMicro X11DPG-QT.
633 - Processors: 2* Intel Gold 6252N 2.3 GHz.
634 - RAM Memory: 12* 16GB DDR4-2933.
635 - Disks: 2* 1.92TB SATA SSD.
636 - NICs configuration:
637 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
638 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
639 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
640 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
641 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
642 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
643 - PCIe Slot8 af:00.xx: empty.
644 - PCIe Slot10 d8:00.xx: empty.
645 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
647 - Physical connectivity:
648 - IPMI and host management ports.
649 - NIC ports connected into 2-node testbed topologies.
650 - Main HW configuration:
651 - Chassis: SuperMicro SYS-7049GP-TRT.
652 - Motherboard: SuperMicro X11DPG-QT.
653 - Processors: 2* Intel Platinum 8280 2.7 GHz.
654 - RAM Memory: 12* 16GB DDR4-2933.
655 - Disks: 2* 1.92TB SATA SSD.
656 - NICs configuration:
657 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
658 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
659 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
660 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
661 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
662 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
663 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
664 - PCIe Slot10 d8:00.xx: empty.
665 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
667 - Physical connectivity:
668 - IPMI and host management ports.
669 - no NIC ports, standalone setup.
670 - Main HW configuration:
671 - Chassis: SuperMicro 1029P-WTRT.
672 - Motherboard: SuperMicro X11DDW-NT.
673 - Processors: 2* Intel Platinum 8280 2.7 GHz.
674 - RAM Memory: 12* 16GB DDR4-2933.
675 - Disks: 4* 1.92TB SATA SSD.
676 - NICs configuration:
681 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
683 - Physical connectivity:
684 - IPMI and host management ports.
685 - NIC ports connected into 2-node testbed topologies.
686 - Main HW configuration:
687 - Chassis: SuperMicro AS-1114S-WTRT
688 - Processors: 1* AMD EPYC 7532 2.4 GHz.
689 - RAM Memory: 8* 32GB DDR4-2933.
690 - Disks: 1* 1TB SATA SSD.
691 - NICs configuration:
692 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
693 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
694 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
695 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
696 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
698 - Physical connectivity:
699 - IPMI and host management ports.
700 - NIC ports connected into 2-node testbed topologies.
701 - Main HW configuration:
702 - Chassis: SuperMicro AS-1114S-WTRT
703 - Processors: 1* AMD EPYC 7532 2.4 GHz.
704 - RAM Memory: 8* 32GB DDR4-2933.
705 - Disks: 1* 1TB SATA SSD.
706 - NICs configuration:
707 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
708 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
709 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
710 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
711 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
713 - Physical connectivity:
714 - IPMI and host management ports.
715 - NIC ports connected into 1-node topologies.
716 - Main HW configuration:
717 - Chassis: GIGABYTE Rack Mount
718 - Motherboard: MT91-FS4-00
719 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
720 - RAM Memory: 16 * 16GB DIMM
721 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
722 - NICs configuration:
724 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
725 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
727 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
728 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
729 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
731 - Physical connectivity:
732 - IPMI(?) and host management ports.
733 - NIC ports connected into 3-node topology.
734 - Main HW configuration:
735 - Chassis: Huawei TaiShan 2280.
736 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
737 - RAM Memory: 8* 16GB DDR4-2400MT/s
738 - Disks: 1* 4TB SATA HDD
739 - NICs configuration:
740 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
741 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
742 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
744 - Physical connectivity:
745 - IPMI and host management ports.
746 - NIC ports connected into 2-node topologies.
747 - Main HW configuration:
748 - Chassis: Gigabyte R181-T90 1U
749 - Motherboard: MT91-FS1
750 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
751 - RAM Memory: 4* 32GB RDIMM
752 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
753 - NICs configuration:
757 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
758 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
760 - Physical connectivity:
761 - IPMI and host management ports.
762 - NIC ports connected into 3-node topologies.
763 - Main HW configuration:
764 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
765 - Motherboard: Mt.Jade Motherboard
766 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
767 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
768 - RAM Memory: 16* 8GB DDR4-3200MT/s
769 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
770 - NICs configuration:
772 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
775 21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
777 - Physical connectivity:
778 - IPMI and host management ports.
779 - Main HW configuration:
780 - Chassis: Gigabyte R152-P30-00 1U
781 - Motherboard: MP32-AR1-00
782 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
783 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
784 - RAM Memory: 12* 16GB DDR4-3200MT/s
785 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
786 22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
788 - Physical connectivity:
789 - IPMI and host management ports.
790 - NIC ports connected into 2-node and 3-node topologies.
791 - Main HW configuration:
792 - Chassis: SuperMicro SYS-7049GP-TRT.
793 - Motherboard: SuperMicro X11DPG-QT.
794 - Processors: 2* Intel Platinum 8180 2.5 GHz.
795 - RAM Memory: 16* 16GB DDR4-2666MHz.
796 - Disks: 2* 1.6TB 6G SATA SSD.
797 - NICs configuration:
798 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
799 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
800 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
801 - PCIe Slot9 5e:00.xx: empty.
802 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
803 - PCIe Slot6 86:00.xx: empty.
804 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
805 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
806 23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
808 - Physical connectivity:
809 - IPMI and host management ports.
810 - NIC ports connected into 2-node or 3-node testbed topologies.
811 - Main HW configuration:
812 - Chassis: SuperMicro SYS-740GP-TNRT.
813 - Motherboard: Super X12DPG-QT6.
814 - Processors: 2* Intel Platinum 8358 2.6 GHz.
815 - RAM Memory: 16* 16GB DDR4-3200.
816 - Disks: 2* 960GB SATA SSD.
817 - NICs configuration:
818 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
819 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
820 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
821 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
822 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
823 - PCIe Slot6 86:00.xx: empty.
824 - PCIe Slot8 af:00.xx: empty.
825 - PCIe Slot10 d8:00.xx: empty.
826 24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
828 - Physical connectivity:
829 - IPMI and host management ports.
830 - NIC ports connected into 2-node testbed topologies.
831 - Main HW configuration:
832 - Chassis: SuperMicro SYS-740GP-TNRT.
833 - Motherboard: Super X12DPG-QT6.
834 - Processors: 2* Intel Platinum 8358 2.6 GHz.
835 - RAM Memory: 16* 16GB DDR4-3200.
836 - Disks: 2* 960GB SATA SSD.
837 - NICs configuration:
838 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
839 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
840 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
841 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
842 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
843 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
844 - PCIe Slot8 af:00.xx: empty.
845 - PCIe Slot10 d8:00.xx: empty.
846 25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
848 - Physical connectivity:
849 - IPMI and host management ports.
850 - NIC ports connected into 3-node testbed topologies.
851 - Main HW configuration:
852 - Chassis: SuperMicro SYS-740GP-TNRT.
853 - Motherboard: Super X12DPG-QT6.
854 - Processors: 2* Intel Platinum 8358 2.6 GHz.
855 - RAM Memory: 16* 16GB DDR4-3200.
856 - Disks: 2* 960GB SATA SSD.
857 - NICs configuration:
858 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
859 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
860 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
861 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
862 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
863 - PCIe Slot6 86:00.xx: empty.
864 - PCIe Slot8 af:00.xx: empty.
865 - PCIe Slot10 d8:00.xx: empty.
866 26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
868 - Physical connectivity:
869 - IPMI and host management ports.
870 - NIC ports connected into 2-node and/or 3-node testbed topologies.
871 - Main HW configuration:
872 - Chassis: SuperMicro SYS-740GP-TNRT.
873 - Motherboard: Super X12DPG-QT6.
874 - Processors: 2* Intel Platinum 8358 2.6 GHz.
875 - RAM Memory: 16* 16GB DDR4-3200.
876 - Disks: 2* 960GB SATA SSD.
877 - NICs configuration:
878 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
879 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
880 - PCIe Slot4 3b:00.xx: empty.
881 - PCIe Slot9 5e:00.xx: empty.
882 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
883 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
884 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
885 - PCIe Slot10 d8:00.xx: empty.
886 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
888 - Physical connectivity:
889 - IPMI and host management ports.
890 - NIC ports connected into 3-node testbed topology.
891 - Main HW configuration:
892 - Chassis: Intel JACOBSVILLE SDP.
893 - Motherboard: Intel JACOBSVILLE E63448-400.
894 - Processors: 1* Intel Atom P5362B 2.2 GHz.
895 - RAM Memory: 2* 16GB DDR4-2933.
896 - Disks: ?* ? SATA SSD.
897 - NICs configuration:
898 - Numa0: (x16, PCIe3.0 lane)
899 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
902 ### Naming Convention
904 Following naming convention is used within this page to specify physical
905 connectivity and wiring across defined CSIT testbeds:
908 - testbedname: testbedN.
910 - traffic-generator: tN-tgW.
911 - system-under-testX: tN-sutX.
916 - N - testbed number.
917 - tgW - server acts as traffic-generator with W index.
918 - sutX - server acts as system-under-test with X index.
919 - Y - PCIe slot number denoting a NIC card number within the host.
920 - Z - port number on the NIC card.
923 ## Testbeds Configuration
925 ### Per Testbed Server Allocation and Naming
927 #### 1-Node-Skylake Servers (1n-skx) PROD
930 - SUT [Server-Type-B6]:
931 - testbedname: testbed11.
932 - hostname: s1-t11-sut1.
933 - IPMI IP: 10.30.50.47
934 - Host IP: 10.30.51.50
936 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
937 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
938 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
939 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
940 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
941 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
942 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
943 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
944 - SUT [Server-Type-B6]:
945 - testbedname: testbed12.
946 - hostname: s2-t12-sut1.
947 - IPMI IP: 10.30.50.48
948 - Host IP: 10.30.51.51
950 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
951 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
952 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
953 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
954 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
955 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
956 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
957 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
960 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
963 - SUT [Server-Type-E11]:
964 - testbedname: testbed13
965 - hostname: s55-t13-sut1
966 - IPMI IP: 10.30.50.70
967 - Host IP: 10.30.51.70
969 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
970 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
971 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
972 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
973 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
974 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
975 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
976 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
977 - SUT [Server-Type-E11]:
978 - testbedname: testbed14
979 - hostname: s56-t14-sut1
980 - IPMI IP: 10.30.50.71
981 - Host IP: 10.30.51.71
983 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
984 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
985 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
986 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
987 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
988 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
989 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
990 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
993 #### 1-Node-Cascadelake Servers (1n-clx) PROD
996 - SUT [Server-Type-C1]:
997 - testbedname: testbed11.
998 - hostname: s32-t14-sut1.
999 - IPMI IP: 10.30.55.17
1000 - Host IP: 10.32.8.17
1002 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1003 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1004 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1005 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1006 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1007 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1008 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1009 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1012 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1015 - SUT [Server-Type-B8]:
1016 - testbedname: testbed25.
1017 - hostname: s25-t25-sut1.
1018 - IPMI IP: 10.30.50.58
1019 - Host IP: 10.30.51.61
1021 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1022 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1023 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1024 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1025 - TG [Server-Type-B7]:
1026 - testbedname: testbed25.
1027 - hostname: s26-t25-tg1.
1028 - IPMI IP: 10.30.50.59
1029 - Host IP: 10.30.51.62
1031 - s26-t25-tg1-p1 - 10GE-port1.
1032 - s26-t25-tg1-p2 - 10GE-port2.
1033 - s26-t25-tg1-p3 - 10GE-port3.
1034 - s26-t25-tg1-p4 - 10GE-port4.
1037 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1040 - SUT [Server-Type-C2]:
1041 - testbedname: testbed27.
1042 - hostname: s33-t27-sut1.
1043 - IPMI IP: 10.30.55.18
1044 - Host IP: 10.32.8.18
1046 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1047 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1048 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1049 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1050 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1051 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1052 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1053 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1054 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1055 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1056 - TG [Server-Type-C3]:
1057 - testbedname: testbed27.
1058 - hostname: s34-t27-tg1.
1059 - IPMI IP: 10.30.55.19
1060 - Host IP: 10.32.8.19
1062 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1063 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1064 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1065 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1066 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1067 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1068 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1069 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1070 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1071 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1072 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1073 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1074 - SUT [Server-Type-C2]:
1075 - testbedname: testbed28.
1076 - hostname: s35-t28-sut1.
1077 - IPMI IP: 10.30.55.20
1078 - Host IP: 10.32.8.20
1080 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1081 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1082 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1083 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1084 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1085 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1086 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1087 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1088 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1089 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1090 - TG [Server-Type-C3]:
1091 - testbedname: testbed28.
1092 - hostname: s36-t28-tg1.
1093 - IPMI IP: 10.30.55.21
1094 - Host IP: 10.32.8.21
1096 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1097 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1098 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1099 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1100 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1101 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1102 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1103 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1104 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1105 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1106 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1107 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1108 - SUT [Server-Type-C2]:
1109 - testbedname: testbed29.
1110 - hostname: s37-t29-sut1.
1111 - IPMI IP: 10.30.55.22
1112 - Host IP: 10.32.8.22
1114 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1115 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1116 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1117 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1118 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1119 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1120 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1121 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1122 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1123 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1124 - TG [Server-Type-C3]:
1125 - testbedname: testbed29.
1126 - hostname: s38-t29-tg1.
1127 - IPMI IP: 10.30.55.23
1128 - Host IP: 10.32.8.23
1130 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1131 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1132 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1133 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1134 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1135 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1136 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1137 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1138 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1139 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1142 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1145 - SUT [Server-Type-D1]:
1146 - testbedname: testbed210.
1147 - hostname: s60-t210-sut1.
1148 - IPMI IP: 10.30.55.24
1149 - Host IP: 10.32.8.24
1151 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1152 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1153 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1154 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1155 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1156 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1157 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1158 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1159 - TG [Server-Type-D2]:
1160 - testbedname: testbed210.
1161 - hostname: s61-t210-tg1.
1162 - IPMI IP: 10.30.55.25
1163 - Host IP: 10.32.8.25
1165 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1166 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1167 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1168 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1169 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1170 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1171 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1172 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1175 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1177 Note: Server19 (TG) is shared between testbed33 & testbed211
1180 - SUT [Server-Type-E22]:
1181 - testbedname: testbed211.
1182 - hostname: s27-t211-sut1.
1183 - IPMI IP: 10.30.50.69
1184 - Host IP: 10.30.51.69
1186 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1187 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1188 - TG [Server-Type-E31]:
1189 - testbedname: testbed33 and testbed211.
1190 - hostname: s19-t33t211-tg1.
1191 - IPMI IP: 10.30.50.46
1192 - Host IP: 10.30.51.49
1194 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1195 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1196 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1197 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1198 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1199 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1200 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1201 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1202 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1203 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1204 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1205 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1208 #### 2-Node-Icelake Servers (2n-icx) PROD
1211 - SUT [Server-Type-F1]:
1212 - testbedname: testbed212.
1213 - hostname: s71-t212-sut1.
1214 - IPMI IP: 10.30.51.81
1215 - Host IP: 10.30.50.81
1217 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1220 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1221 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1222 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1223 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1224 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1225 - TG [Server-Type-F2]:
1226 - testbedname: testbed212.
1227 - hostname: s72-t212-tg1.
1228 - IPMI IP: 10.30.51.82
1229 - Host IP: 10.30.50.82
1231 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1232 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1233 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1234 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1235 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1236 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1237 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1238 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1239 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1240 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1241 - SUT [Server-Type-F1]:
1242 - testbedname: testbed213.
1243 - hostname: s83-t213-sut1.
1244 - IPMI IP: 10.30.51.83
1245 - Host IP: 10.30.50.83
1247 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1248 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1249 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1250 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1251 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1252 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1253 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1254 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1255 - TG [Server-Type-F2]:
1256 - testbedname: testbed213.
1257 - hostname: s84-t213-tg1.
1258 - IPMI IP: 10.30.51.84
1259 - Host IP: 10.30.50.84
1261 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1262 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1263 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1264 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1265 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1266 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1267 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1268 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1269 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1270 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1271 - SUT [Server-Type-F1]:
1272 - testbedname: testbed214.
1273 - hostname: s85-t214-sut1.
1274 - IPMI IP: 10.30.51.85
1275 - Host IP: 10.30.50.85
1277 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1278 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1279 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1280 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1281 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1282 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1283 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1284 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1285 - TG [Server-Type-F2]:
1286 - testbedname: testbed214.
1287 - hostname: s86-t214-tg1.
1288 - IPMI IP: 10.30.51.86
1289 - Host IP: 10.30.50.86
1291 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1292 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1293 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1294 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1295 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1296 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1297 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1298 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1299 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1300 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1301 - SUT [Server-Type-F1]:
1302 - testbedname: testbed215.
1303 - hostname: s87-t215-sut1.
1304 - IPMI IP: 10.30.51.87
1305 - Host IP: 10.30.50.87
1307 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1308 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1309 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1310 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1311 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1312 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1313 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1314 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1315 - TG [Server-Type-F2]:
1316 - testbedname: testbed215.
1317 - hostname: s88-t215-tg1.
1318 - IPMI IP: 10.30.51.88
1319 - Host IP: 10.30.50.88
1321 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1322 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1323 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1324 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1325 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1326 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1327 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1328 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1329 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1330 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1333 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1335 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1338 - ServerB22 [Server-Type-B5]:
1339 - testbedname: testbed35.
1340 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1341 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1342 - Host IP: 10.30.51.9
1344 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1345 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1347 - ServerB23 [Server-Type-B5]:
1348 - testbedname: testbed35.
1349 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1350 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1351 - Host IP: 10.30.51.10
1353 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1354 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1356 - ServerB24 [Server-Type-B5]:
1357 - testbedname: testbed35.
1358 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1359 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1360 - Host IP: 10.30.51.11
1362 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1363 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1367 #### 3-Node-Taishan Servers (3n-tsh) PROD
1369 Note: Server19 (TG) is shared between testbed33 & testbed211
1372 - SUT [Server-Type-E21]:
1373 - testbedname: testbed33.
1374 - hostname: s17-t33-sut1.
1375 - IPMI IP: 10.30.50.36
1376 - Host IP: 10.30.51.36
1378 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1379 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1380 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1381 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1382 - SUT [Server-Type-E21]:
1383 - testbedname: testbed33.
1384 - hostname: s18-t33-sut2.
1385 - IPMI IP: 10.30.50.37
1386 - Host IP: 10.30.51.37
1388 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1389 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1390 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1391 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1392 - TG [Server-Type-E31]:
1393 - testbedname: testbed33 and testbed211.
1394 - hostname: s19-t33t211-tg1.
1395 - IPMI IP: 10.30.50.46
1396 - Host IP: 10.30.51.49
1398 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1399 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1400 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1401 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1402 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1403 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1404 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1405 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1406 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1407 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1408 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1409 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1412 #### 3-Node-Altra Servers (3n-alt) PROD
1415 - SUT [Server-Type-E23]:
1416 - testbedname: testbed34.
1417 - hostname: s62-t34-sut1.
1418 - IPMI IP: 10.30.50.72
1419 - Host IP: 10.30.51.72
1421 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1422 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1423 - SUT [Server-Type-E23]:
1424 - testbedname: testbed34.
1425 - hostname: s63-t34-sut2.
1426 - IPMI IP: 10.30.50.73
1427 - Host IP: 10.30.51.73
1429 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1430 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1431 - TG [Server-Type-F4]:
1432 - testbedname: testbed34.
1433 - hostname: s64-t34-tg1.
1434 - IPMI IP: 10.30.50.74
1435 - Host IP: 10.30.51.74
1437 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1438 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1439 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1440 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1441 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1442 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1443 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1444 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1445 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1446 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1449 #### 3-Node-Icelake Servers (3n-icx) PROD
1452 - ServerF1 [Server-Type-F1]:
1453 - testbedname: testbed37.
1454 - hostname: s65-t37-sut1.
1455 - IPMI IP: 10.30.50.75
1456 - Host IP: 10.30.51.75
1458 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1459 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1460 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1461 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1462 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1463 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1464 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1465 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1466 - ServerF1 [Server-Type-F1]:
1467 - testbedname: testbed37.
1468 - hostname: s66-t37-sut2.
1469 - IPMI IP: 10.30.50.76
1470 - Host IP: 10.30.51.76
1472 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1473 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1474 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1475 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1476 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1477 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1478 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1479 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1480 - ServerF3 [Server-Type-F3]:
1481 - testbedname: testbed37.
1482 - hostname: s67-t37-tg1.
1483 - IPMI IP: 10.30.50.77
1484 - Host IP: 10.30.51.77
1486 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1487 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1488 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1489 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1490 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1491 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1492 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1493 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1494 - ServerF1 [Server-Type-F1]:
1495 - testbedname: testbed38.
1496 - hostname: s78-t38-sut1.
1497 - IPMI IP: 10.30.50.78
1498 - Host IP: 10.30.51.78
1500 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1501 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1502 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1503 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1504 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1505 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1506 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1507 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1508 - ServerF1 [Server-Type-F1]:
1509 - testbedname: testbed38.
1510 - hostname: s79-t38-sut2.
1511 - IPMI IP: 10.30.50.79
1512 - Host IP: 10.30.51.79
1514 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1515 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1516 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1517 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1518 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1519 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1520 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1521 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1522 - ServerF3 [Server-Type-F3]:
1523 - testbedname: testbed38.
1524 - hostname: s80-t38-tg1.
1525 - IPMI IP: 10.30.50.80
1526 - Host IP: 10.30.51.80
1528 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1529 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1530 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1531 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1532 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1533 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1534 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1535 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1538 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1541 - ServerG1 [Server-Type-G1]:
1542 - testbedname: testbed39.
1543 - hostname: s93-t39-sut1.
1544 - IPMI IP: 10.30.50.93
1545 - Host IP: 10.30.51.93
1547 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1548 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1549 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1550 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1551 - ServerG1 [Server-Type-G1]:
1552 - testbedname: testbed39.
1553 - hostname: s94-t39-sut2.
1554 - IPMI IP: 10.30.50.94
1555 - Host IP: 10.30.51.94
1557 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1558 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1559 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1560 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1561 - ServerF4 [Server-Type-F4]:
1562 - testbedname: testbed39.
1563 - hostname: s89-t39t310-tg1.
1564 - IPMI IP: 10.30.50.89
1565 - Host IP: 10.30.51.89
1567 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1568 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1569 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1570 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1573 ### Per Testbed Wiring
1575 #### 1-Node-Skylake Wiring (1n-skx) PROD
1579 - ring1 10GE-ports x710-4p10GE:
1580 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1581 - ring2 10GE-ports x710-4p10GE:
1582 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1583 - ring3 10GE-ports x710-4p10GE:
1584 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1585 - ring4 10GE-ports x710-4p10GE:
1586 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1587 - ring5 100GE-ports e810-2p100GE:
1588 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1589 - ring6 100GE-ports e810-2p100GE:
1590 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1592 - ring1 10GE-ports x710-4p10GE:
1593 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1594 - ring2 10GE-ports x710-4p10GE:
1595 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1596 - ring3 10GE-ports x710-4p10GE:
1597 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1598 - ring4 10GE-ports x710-4p10GE:
1599 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1600 - ring5 100GE-ports e810-2p100GE:
1601 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1602 - ring6 100GE-ports e810-2p100GE:
1603 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1606 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1610 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1611 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1612 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1613 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1614 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1615 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1616 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1617 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1620 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1621 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1622 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1623 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1624 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1625 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1626 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1627 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1630 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1634 - link1 10GE-port x710-4p10GE on SUT:
1635 - t25-tg1-p1 to t25-sut1-c2/p1.
1636 - link2 10GE-port x710-4p10GE on SUT:
1637 - t25-tg1-p2 to t25-sut1-c2/p2.
1638 - link3 10GE-port x710-4p10GE on SUT:
1639 - t25-tg1-p3 to t25-sut1-c2/p3.
1640 - link4 10GE-port x710-4p10GE on SUT:
1641 - t25-tg1-p4 to t25-sut1-c2/p4.
1644 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1648 - ring1 10GE-ports x710-4p10GE on SUT:
1649 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1650 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1651 - ring2 10GE-ports x710-4p10GE on SUT:
1652 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1653 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1654 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1655 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1656 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1657 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1658 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1659 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1660 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1661 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1662 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1663 - ring6 100GE-ports e810-2p100GE on TG:
1664 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1665 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1667 - ring1 10GE-ports x710-4p10GE on SUT:
1668 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1669 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1670 - ring2 10GE-ports x710-4p10GE on SUT:
1671 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1672 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1673 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1674 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1675 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1676 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1677 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1678 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1679 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1680 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1681 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1682 - ring6 100GE-ports e810-2p100GE on TG:
1683 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1684 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1686 - ring1 10GE-ports x710-4p10GE on SUT:
1687 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1688 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1689 - ring2 10GE-ports x710-4p10GE on SUT:
1690 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1691 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1692 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1693 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1694 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1695 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1696 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1697 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1698 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1699 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1700 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1703 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1707 - ring1 10GE-ports x710-4p10GE on SUT:
1708 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1709 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1710 - ring2 10GE-ports x710-4p10GE on SUT:
1711 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1712 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1713 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1714 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1715 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1716 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1717 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1718 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1721 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1725 - ring1 10GE-ports x520-2p10GE on SUTs:
1726 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1727 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1730 #### 2-Node-Icelake Wiring (2n-icx) PROD
1734 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1735 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1736 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1737 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1738 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1739 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1740 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1741 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1742 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1743 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1744 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1745 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1746 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1747 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1749 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1750 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1751 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1752 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1753 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1754 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1755 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1756 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1757 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1758 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1759 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1760 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1761 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1762 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1764 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1765 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1766 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1767 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1768 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1769 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1770 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1771 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1772 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1773 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1774 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1775 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1776 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1777 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1779 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1780 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1781 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1782 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1783 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1784 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1785 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1786 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1787 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1788 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1789 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1790 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1791 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1792 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1795 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
1801 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1805 - ring1 10GE-ports x520-2p10GE on SUTs:
1806 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1807 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1808 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1809 - ring2 25GE-ports cx4-2p25GE on SUTs:
1810 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1811 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1812 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1815 #### 3-Node-Altra Wiring (3n-alt) PROD
1819 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1820 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1821 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1822 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1825 #### 3-Node-Icelake Wiring (3n-icx) PROD
1829 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1830 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1831 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1832 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1833 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1834 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1835 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1836 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1837 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1838 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1839 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1840 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1841 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1842 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1843 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1845 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1846 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1847 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1848 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1849 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1850 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1851 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1852 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1853 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1854 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1855 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1856 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1857 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1858 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1859 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1862 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
1866 - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
1867 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1868 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1869 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1870 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1871 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1872 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1880 1. Ixia PerfectStorm One Appliance
1882 - Chassis: PS10GE4NG.
1883 - Motherboard: SuperMicro X11DPG-QT.
1884 - Processors: Quad-Core, Intel Processor.
1885 - HW accelerators: FPGA offload.
1887 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1888 - Physical Interfaces: 4 * 10GE SFP+.
1889 - Operating System: Native IxOS.
1895 1. Arm Cortex A-72 servers
1896 - 2 * ThunderX2 (VPP Device)
1897 - Chassis: GIGABYTE Rack Mount
1898 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1899 - RAM Memory: 16* 16GB DIMM
1900 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1901 - 1 * ThunderX2 (Performance)
1902 - Chassis: GIGABYTE Rack Mount
1903 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1904 - RAM Memory: 4* 32GB RDIMM
1905 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1906 - 2 * Huawei TaiShan 2280.
1907 - Chassis: Huawei TaiShan 2280.
1908 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1909 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1910 - Disks: 1* 4TB SATA HDD.
1911 2. Arm Neoverse N1 servers
1912 - 2 * Ampere Altra (Performance)
1913 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
1914 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
1915 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
1916 - RAM Memory: 16* 8GB DDR4-3200MT/s
1917 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
1918 - 2 * Ampere Altra (Build)
1919 - Chassis: Gigabyte R152-P30-00 1U
1920 - Motherboard: MP32-AR1-00
1921 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
1922 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
1923 - RAM Memory: 12* 16GB DDR4-3200MT/s
1924 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
1927 ### Xeon and Atom Servers
1930 1. Intel Xeon servers:
1931 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1932 - Chassis: SuperMicro SYS-7049GP-TRT.
1933 - Motherboard: SuperMicro X11DPG-QT.
1934 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1935 - RAM Memory: 16* 16GB DDR4-2666MHz.
1936 - Disks: 2* 1.6TB 6G SATA SSD.
1937 2. Intel Atom servers with Rangely processors.
1938 - 3 * Netgate XG-2758-1u
1939 - Chassis: Netgate XG-2758-1u
1940 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1941 - RAM Memory: 16GB ECC
1945 ### Network Interface Cards
1958 ### Pluggables and Cables