1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
9 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
10 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
11 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
12 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
13 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
14 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
15 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
16 1. [Server Management](#server-management)
17 1. [Requirements](#requirements)
18 1. [Addressing](#addressing)
19 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
20 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
21 1. [Server Type Specification](#server-type-specification)
22 1. [Server and Port Naming](#server-and-port-naming)
23 1. [Testbeds Configuration](#testbeds-configuration)
24 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
25 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
26 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
27 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
28 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
29 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
30 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
31 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
32 1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
33 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
34 1. [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
35 1. [Per Testbed Wiring](#per-testbed-wiring)
36 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
37 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
38 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
39 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
40 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
41 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
42 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
43 1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
44 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
45 1. [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
46 1. [Inventory](#inventory)
47 1. [Appliances](#appliances)
48 1. [Arm Servers](#arm-servers)
49 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
50 1. [Network Interface Cards](#network-interface-cards)
51 1. [Pluggables and Cables](#pluggables-and-cables)
52 1. [Other Parts](#other-parts)
56 This note includes specification of the physical testbed infrastructure
57 hosted by LFN FD.io CSIT project.
64 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
65 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0
66 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0
67 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
68 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
69 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
70 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
71 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
72 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
73 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
74 10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
75 11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0
76 12. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
77 Totals: 18 28 15 12 19 1 2 3 1 2 2
80 ### 1-Node-Skylake Xeon Intel (1n-skx)
82 Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
83 ports connected back-to-back.
84 Used for FD.io VPP_Device functional driver tests.
86 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
88 Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
89 ports connected back-to-back.
90 Used for FD.io VPP_Device functional driver tests.
92 ### 2-Node-Skylake Xeon Intel (2n-skx)
94 Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
95 (Type-B2 server) connected back-to-back.
96 Used for FD.io performance tests.
98 ### 2-Node-Denverton Atom Intel (2n-dnv)
100 Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
101 (Type-B2 server) connected back-to-back.
102 Used for FD.io performance tests.
104 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
106 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
107 TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
108 Used for FD.io TCP/IP and HTTP performance tests.
110 ### 3-Node-Haswell Xeon Intel (3n-hsw)
112 Each 3-Node-Haswell testbed includes two SUTs (Type-A1 servers) and one
113 TG (Type-A2 server) connected in full-mesh triangle.
114 Used for FD.io performance tests.
116 ### 3-Node-Skylake Xeon Intel (3n-skx)
118 Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
119 TG (Type-B2 server) connected in full-mesh triangle.
120 Used for FD.io performance tests.
122 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
124 Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
125 (Type-B2 server) connected in full-mesh triangle.
126 Used for FD.io performance tests.
128 ### 3-Node-MACCHIATObin Arm Marvell
130 Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
131 one TG (Type-B2 server) connected in full-mesh triangle.
132 Used for FD.io performance tests.
134 ### 3-Node-Rangeley Atom Testbeds
136 Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
137 and one TG (Type-2 server) connected in full-mesh triangle.
138 Used for FD.io performance tests.
144 For management purposes, each server must have following two ports
145 connected to the management network:
149 - IPMI - Intelligent Platform Management Interface.
150 - Required for access to embedded server management with WebUI, CLI, SNMPv3,
151 IPMIv2.0, for firmware (BIOS) and OS updates.
152 - 1GE/10GE/40GE management port
153 - hostOS management port for general system management.
158 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
159 port, which are connected to two different VLANs.
163 - Subnet: 10.30.50.0/24
164 - Gateway: 10.30.50.1
165 - Broadcast: 10.30.50.255
166 - DNS1: 199.204.44.24
167 - DNS2: 199.204.47.54
169 - Subnet: 10.30.51.0/24
170 - Gateway: 10.30.51.1
171 - Broadcast: 10.30.51.255
172 - DNS1: 199.204.44.24
173 - DNS2: 199.204.47.54
176 To access these hosts, VPN connection is required.
178 ### LOM (IPMI) VLAN IP Addresses
181 ------------ | -------
184 10.30.50.2 | LF Reserved
185 10.30.50.3 | LF Reserved
186 10.30.50.4 | LF Reserved
187 10.30.50.5 | LF Reserved
188 10.30.50.6 | LF Reserved
189 10.30.50.7 | LF Reserved
190 10.30.50.8 | LF Reserved
191 10.30.50.9 | LF Reserved
192 10.30.50.10 | LF Reserved
193 10.30.50.11 | LF Reserved
194 10.30.50.12 | LF Reserved
195 10.30.50.13 | LF Reserved
196 10.30.50.14 | LF Reserved
197 10.30.50.15 | LF Reserved
199 10.30.50.17 | t1-sut1
200 10.30.50.18 | t1-sut2
202 10.30.50.21 | t2-sut1
203 10.30.50.22 | t2-sut2
205 10.30.50.25 | t3-sut1
206 10.30.50.26 | t3-sut-2
207 10.30.50.28 | t4-sut1
208 10.30.50.29 | t4-sut2
209 10.30.50.30 | t4-sut3
210 10.30.50.36 | s17-t33-sut1
211 10.30.50.37 | s18-t33-sut2
212 10.30.50.41 | s3-t21-sut1
213 10.30.50.42 | s4-t21-tg1
214 10.30.50.43 | s11-t31-sut1
215 10.30.50.44 | s12-t31-sut2
216 10.30.50.45 | s13-t31-tg1
217 10.30.50.46 | s19-t33t34-tg1
218 10.30.50.47 | s1-t11-sut1
219 10.30.50.48 | s2-t12-sut1
220 10.30.50.49 | s5-t22-sut1
221 10.30.50.50 | s6-t22-tg1
222 10.30.50.51 | s7-t23-sut1
223 10.30.50.52 | s8-t23-tg1
224 10.30.50.53 | s9-t24-sut1
225 10.30.50.54 | s10-t24-tg1
226 10.30.50.55 | s14-t32-sut1
227 10.30.50.56 | s15-t32-sut2
228 10.30.50.57 | s16-t32-tg1
229 10.30.50.58 | s25-t25-sut1
230 10.30.50.59 | s26-t25-tg1
231 10.30.50.69 | s27-t13-sut
232 10.30.50.255 | Broadcast
234 ### Management VLAN IP Addresses
237 ------------------------- | -------
240 10.30.51.2 | LF Reserved
241 10.30.51.3 | LF Reserved
242 10.30.51.4 | LF Reserved
243 10.30.51.5 | LF Reserved
244 10.30.51.6 | LF Reserved
245 10.30.51.7 | LF Reserved
246 10.30.51.8 | LF Reserved
247 10.30.51.9 | s22-t35-sut1 (netgate-1)
248 10.30.51.10 | s23-t35-sut2 (netgate-2)
249 10.30.51.11 | s24-t35-sut3 (netgate-3)
250 10.30.51.12 | softiron-1
251 10.30.51.13 | softiron-2
252 10.30.51.14 | softiron-3
253 10.30.51.15 | LF Reserved
255 10.30.51.17 | t1-sut1
256 10.30.51.18 | t1-sut2
258 10.30.51.21 | t2-sut1
259 10.30.51.22 | t2-sut2
261 10.30.51.25 | t3-sut1
262 10.30.51.26 | t3-sut-2
263 10.30.51.28 | t4-sut1
264 10.30.51.29 | t4-sut2
265 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
266 10.30.51.30 | t4-sut3
267 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
268 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
269 10.30.51.36 | s17-t33-sut1
270 10.30.51.37 | s18-t33-sut2
271 10.30.51.41 | s20-t34-sut1
272 10.30.51.42 | s21-t34-sut2
273 10.30.51.44 | s3-t21-sut1
274 10.30.51.45 | s4-t21-tg1
275 10.30.51.46 | s11-t31-sut1
276 10.30.51.47 | s12-t31-sut2
277 10.30.51.48 | s13-t31-tg1
278 10.30.51.49 | s19-t33t34-tg1
279 10.30.51.50 | s1-t11-sut1
280 10.30.51.51 | s2-t12-sut1
281 10.30.51.52 | s5-t22-sut1
282 10.30.51.53 | s6-t22-tg1
283 10.30.51.54 | s7-t23-sut1
284 10.30.51.55 | s8-t23-tg1
285 10.30.51.56 | s9-t24-sut1
286 10.30.51.57 | s10-t24-tg1
287 10.30.51.58 | s14-t32-sut1
288 10.30.51.59 | s15-t32-sut2
289 10.30.51.60 | s16-t32-tg1
290 10.30.51.61 | s25-t25-sut1
291 10.30.51.62 | s26-t25-tg1
292 10.30.51.69 | s27-t13-sut1
293 10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED
294 10.30.51.106-10.30.51.180 | VIRL2
295 10.30.51.181-10.30.51.254 | VIRL3
296 10.30.51.255 | Broadcast
298 ## Server Type Specification
300 FD.io CSIT lab contains following server types:
302 1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
303 - Quantity: 6 servers.
304 - Physical connectivity:
305 - CIMC and host management ports.
306 - NIC ports connected in 3-node topologies.
307 - Main HW configuration:
308 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
309 - Processors: 2* E5-2699v3 2.3 GHz.
310 - RAM Memory: 16* 32GB DDR4-2133MHz.
311 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
312 - NICs configuration:
313 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
314 - PCIe Slot1: Cisco VIC 1385 2p40GE.
315 - PCIe Slot2: Intel NIC x520 2p10GE.
317 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
318 - PCIe Slot4: Intel NIC xl710 2p40GE.
319 - PCIe Slot5: Intel NIC x710 2p10GE.
320 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
321 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
322 2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
323 - Quantity: 3 servers.
324 - Physical connectivity:
325 - CIMC and host management ports.
326 - NIC ports connected in 3-node topologies.
327 - Main HW configuration:
328 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
329 - Processors: 2* E5-2699v3 2.3 GHz.
330 - RAM Memory: 16* 32GB DDR4-2133MHz.
331 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
332 - NICs configuration:
333 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
334 - PCIe Slot1: Intel NIC xl710 2p40GE.
335 - PCIe Slot2: Intel NIC x710 2p10GE.
336 - PCIe Slot3: Intel NIC x710 2p10GE.
337 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
338 - PCIe Slot4: Intel NIC xl710 2p40GE.
339 - PCIe Slot5: Intel NIC x710 2p10GE.
340 - PCIe Slot6: Intel NIC x710 2p10GE.
342 3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
343 - Quantity: 3 servers.
344 - Physical connectivity:
345 - CIMC and host management ports.
346 - no NIC ports, standalone setup.
347 - Main HW configuration:
348 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
349 - Processors: 2* E5-2699v3 2.3 GHz.
350 - RAM Memory: 16* 32GB DDR4-2133MHz.
351 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
352 - NICs configuration:
353 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
355 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
358 4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
360 - Physical connectivity:
361 - IPMI and host management ports.
362 - NIC ports connected into 2-node and 3-node topologies.
363 - Main HW configuration:
364 - Chassis: SuperMicro SYS-7049GP-TRT.
365 - Motherboard: SuperMicro X11DPG-QT.
366 - Processors: 2* Intel Platinum 8180 2.3 GHz.
367 - RAM Memory: 16* 16GB DDR4-2666MHz.
368 - Disks: 2* 1.6TB 6G SATA SSD.
369 - NICs configuration:
370 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
371 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
372 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
373 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
374 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
375 - PCIe Slot6 86:00.xx: empty.
376 - PCIe Slot8 af:00.xx: empty.
377 - PCIe Slot10 d8:00.xx: empty.
378 2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
380 - Physical connectivity:
381 - IPMI and host management ports.
382 - NIC ports connected into 2-node and 3-node topologies.
383 - Main HW configuration:
384 - Chassis: SuperMicro SYS-7049GP-TRT.
385 - Motherboard: SuperMicro X11DPG-QT.
386 - Processors: 2* Intel Platinum 8180 2.3 GHz.
387 - RAM Memory: 16* 16GB DDR4-2666MHz.
388 - Disks: 2* 1.6TB 6G SATA SSD.
389 - NICs configuration:
390 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
391 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
392 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
393 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
394 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
395 - PCIe Slot6 86:00.xx: empty.
396 - PCIe Slot8 af:00.xx: empty.
397 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
398 3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
400 - Physical connectivity:
401 - IPMI(?) and host management ports.
402 - NIC ports connected into 3-node topology.
403 - Main HW configuration:
404 - Chassis: Huawei TaiShan 2280.
405 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
406 - RAM Memory: 8* 16GB DDR4-2400MT/s
407 - Disks: 1* 4TB SATA HDD
408 - NICs configuration:
409 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
410 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
411 4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
413 - Physical connectivity:
414 - Host management ports.
415 - NIC ports connected into 2-node and 3-node topologies.
416 - Main HW configuration:
417 - Chassis: MACCHIATObin.
418 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
419 - RAM Memory: 1* 16GB DDR4
420 - Disks: 1* 128GB(?) SATA SDD
421 - NICs configuration:
422 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
423 5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
424 - Quantity: TBD based on testbed allocation.
425 - Physical connectivity:
426 - Management: serial Port (usb) for console
427 - NIC ports connected into 2-node.
428 - Main HW configuration:
429 - Chassis: Netgate XG-2758-1u
430 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
431 - RAM Memory: 16GB ECC
433 - NICs configuration:
434 - 2x 10Gb Intel 82599ES
436 6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
438 - Physical connectivity:
439 - IPMI and host management ports.
440 - NIC ports connected into 2-node and 3-node topologies.
441 - Main HW configuration:
442 - Chassis: SuperMicro SYS-7049GP-TRT.
443 - Motherboard: SuperMicro X11DPG-QT.
444 - Processors: 2* Intel Platinum 8180 2.3 GHz.
445 - RAM Memory: 16* 16GB DDR4-2666MHz.
446 - Disks: 2* 1.6TB 6G SATA SSD.
447 - NICs configuration:
448 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
449 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
450 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
451 - PCIe Slot9 5e:00.xx: empty.
452 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
453 - PCIe Slot6 86:00.xx: empty.
454 - PCIe Slot8 af:00.xx: empty.
455 - PCIe Slot10 d8:00.xx: empty.
456 7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
458 - Physical connectivity:
459 - Host management interface: 10/100/1000-BaseT.
460 - 8-port 10GE SFP+ integrated NIC.
461 - Main HW configuration:
462 - Chassis: PS10GE4NG.
463 - Motherboard: SuperMicro X11DPG-QT.
464 - Processors: Quad-Core, Intel Processor.
465 - HW accelerators: FPGA offload.
467 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
468 - Physical Interfaces: 4 * 10GE SFP+.
469 - Operating System: Native IxOS.
470 - Interface configuration:
475 8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
477 - Physical connectivity:
478 - IPMI and host management ports.
480 - Main HW configuration:
481 - Chassis: SuperMicro SYS-7049GP-TRT.
482 - Motherboard: SuperMicro X11DPG-QT.
483 - Processors: 2* Intel Platinum 8180 2.3 GHz.
484 - RAM Memory: 16* 16GB DDR4-2666MHz.
485 - Disks: 2* 1.6TB 6G SATA SSD.
486 - NICs configuration:
487 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
488 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
489 - PCIe Slot4 3b:00.xx: empty.
490 - PCIe Slot9 5e:00.xx: empty.
491 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
492 - PCIe Slot6 86:00.xx: empty.
493 - PCIe Slot8 af:00.xx: empty.
494 - PCIe Slot10 d8:00.xx: empty.
495 9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
497 - Physical connectivity:
498 - IPMI and host management ports.
499 - NIC ports connected into 1-node topologies.
500 - Main HW configuration:
501 - Chassis: Gigabyte R181-T90 1U
502 - Motheboard: MT91-FS1
503 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
504 - RAM Memory: 4* 32GB RDIMM
505 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
506 - NICs configuration:
508 - PCIe Slot1 05:00.xx: XL710-QDA2.
509 - PCIe Slot3 08:00.xx: XL710-QDA2.
511 - PCIe Slot6 85:00.xx: XL710-QDA2.
512 10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
514 - Physical connectivity:
515 - IPMI and host management ports.
517 - Main HW configuration:
518 - Chassis: SuperMicro SYS-E300-9A
519 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
520 - RAM Memory: 32GB ECC
522 - NICs configuration:
523 - 2x 10Gb Intel x553 fiber ports
524 - 2x 10Gb Intel x553 copper ports
525 - 4x 1GB Intel I350 ports
528 ### Server and Port Naming
530 Following naming convention is used within this page to specify physical
531 connectivity and wiring across defined CSIT testbeds:
534 - testbedname: testbedN.
536 - traffic-generator: tN-tgW.
537 - system-under-testX: tN-sutX.
542 - N - testbed number.
543 - tgW - server acts as traffic-generator with W index.
544 - sutX - server acts as system-under-test with X index.
545 - Y - PCIe slot number denoting a NIC card number within the host.
546 - Z - port number on the NIC card.
549 ## Testbeds Configuration
551 ### Per Testbed Server Allocation and Naming
553 #### 1-Node-Skylake (1n-skx) PROD
556 - ServerB1 [Type-B6]:
557 - testbedname: testbed11.
558 - hostname: s1-t11-sut1.
559 - IPMI IP: 10.30.50.47
560 - Host IP: 10.30.51.50
562 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
563 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
564 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
565 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
566 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
567 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
568 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
569 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
570 - ServerB2 [Type-B6]:
571 - testbedname: testbed12.
572 - hostname: s2-t12-sut1.
573 - IPMI IP: 10.30.50.48
574 - Host IP: 10.30.51.51
576 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
577 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
578 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
579 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
580 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
581 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
582 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
583 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
586 #### 1-Node-Thunderx2 (1n-tx2) WIP
589 - ServerB17 [Type-B9]:
590 - testbedname: testbed13.
591 - hostname: s27-t13-sut1.
592 - IPMI IP: 10.30.50.69
593 - Host IP: 10.30.51.69
595 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
596 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
597 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
598 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
599 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
600 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
603 #### 2-Node-Skylake (2n-skx) PROD
606 - ServerB3 [Type-B1]:
607 - testbedname: testbed21.
608 - hostname: s3-t21-sut1.
609 - IPMI IP: 10.30.50.41
610 - Host IP: 10.30.51.44
612 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
613 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
614 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
615 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
616 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
617 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
618 - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
619 - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
620 - ServerB4 [Type-B2]:
621 - testbedname: testbed21.
622 - hostname: s4-t21-tg1.
623 - IPMI IP: 10.30.50.42
624 - Host IP: 10.30.51.45
626 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
627 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
628 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
629 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
630 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
631 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
632 - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
633 - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
634 - ServerB5 [Type-B1]:
635 - testbedname: testbed22.
636 - hostname: s5-t22-sut1.
637 - IPMI IP: 10.30.50.49
638 - Host IP: 10.30.51.52
640 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
641 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
642 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
643 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
644 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
645 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
646 - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
647 - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
648 - ServerB6 [Type-B2]:
649 - testbedname: testbed22.
650 - hostname: s6-t22-tg1.
651 - IPMI IP: 10.30.50.50
652 - Host IP: 10.30.51.53
654 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
655 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
656 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
657 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
658 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
659 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
660 - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
661 - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
662 - ServerB7 [Type-B1]:
663 - testbedname: testbed23.
664 - hostname: s7-t23-sut1.
665 - IPMI IP: 10.30.50.51
666 - Host IP: 10.30.51.54
668 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
669 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
670 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
671 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
672 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
673 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
674 - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
675 - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
676 - ServerB8 [Type-B2]:
677 - testbedname: testbed23.
678 - hostname: s8-t23-tg1.
679 - IPMI IP: 10.30.50.52
680 - Host IP: 10.30.51.55
682 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
683 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
684 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
685 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
686 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
687 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
688 - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
689 - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
690 - ServerB9 [Type-B1]:
691 - testbedname: testbed24.
692 - hostname: s9-t24-sut1.
693 - IPMI IP: 10.30.50.53
694 - Host IP: 10.30.51.56
696 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
697 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
698 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
699 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
700 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
701 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
702 - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
703 - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
704 - ServerB10 [Type-B2]:
705 - testbedname: testbed24.
706 - hostname: s10-t24-tg1.
707 - IPMI IP: 10.30.50.54
708 - Host IP: 10.30.51.57
710 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
711 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
712 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
713 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
714 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
715 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
716 - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
717 - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
720 #### 2-Node-Denverton (2n-dnv) WIP
722 Note: ServerB28 (TG) is shared between testbed26 & testbed35
725 - ServerB28 [Type-B2]:
726 - testbednames: testbed26 and testbed35.
727 - hostname: s28-t26t35-tg1.
728 - IPMI IP: 10.30.55.10
729 - Host IP: 10.32.8.10
731 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
732 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
733 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
734 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
735 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
736 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
737 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
738 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
739 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
740 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
741 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
742 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
743 - ServerB29 [Type-B10]:
744 - testbednames: testbed26.
745 - hostname: s29-t26-sut1.
746 - IPMI IP: 10.30.55.11
747 - Host IP: 10.32.8.11
749 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
750 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
751 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
752 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
755 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
758 - ServerB25 [Type-B8]:
759 - testbedname: testbed25.
760 - hostname: s25-t25-sut1.
761 - IPMI IP: 10.30.50.58
762 - Host IP: 10.30.51.61
764 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
765 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
766 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
767 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
768 - ServerB26 [Type-B7]:
769 - testbedname: testbed25.
770 - hostname: s26-t25-tg1.
771 - IPMI IP: 10.30.50.59
772 - Host IP: 10.30.51.62
774 - s26-t25-tg1-p1 - 10GE-port1.
775 - s26-t25-tg1-p2 - 10GE-port2.
776 - s26-t25-tg1-p3 - 10GE-port3.
777 - s26-t25-tg1-p4 - 10GE-port4.
780 #### 3-Node-Haswell (3n-hsw) PROD
783 1. Server1 of Type-1:
784 - testbedname: testbed1.
786 - CIMC IP: 10.30.50.17
787 - Host IP: 10.30.51.17
789 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
790 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
791 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
792 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
793 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
794 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
795 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
796 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
797 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
798 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
799 2. Server2 of Type-1:
800 - testbedname: testbed1.
802 - CIMC IP: 10.30.50.18
803 - Host IP: 10.30.51.18
805 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
806 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
807 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
808 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
809 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
810 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
811 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
812 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
813 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
814 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
815 3. Server3 of Type-2:
816 - testbedname: testbed1.
818 - CIMC IP: 10.30.50.16
819 - Host IP: 10.30.51.16
821 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
822 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
823 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
824 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
825 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
826 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
827 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
828 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
829 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
830 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
831 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
832 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
833 4. Server4 of Type-1:
834 - testbedname: testbed2.
836 - CIMC IP: 10.30.50.21
837 - Host IP: 10.30.51.21
839 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
840 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
841 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
842 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
843 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
844 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
845 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
846 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
847 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
848 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
849 5. Server5 of Type-1:
850 - testbedname: testbed2.
852 - CIMC IP: 10.30.50.22
853 - Host IP: 10.30.51.22
855 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
856 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
857 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
858 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
859 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
860 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
861 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
862 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
863 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
864 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
865 6. Server6 of Type-2:
866 - testbedname: testbed2.
868 - CIMC IP: 10.30.50.20
869 - Host IP: 10.30.51.20
871 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
872 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
873 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
874 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
875 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
876 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
877 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
878 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
879 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
880 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
881 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
882 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
883 7. Server7 of Type-1:
884 - testbedname: testbed3.
886 - CIMC IP: 10.30.50.25
887 - Host IP: 10.30.51.25
889 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
890 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
891 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
892 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
893 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
894 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
895 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
896 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
897 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
898 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
899 8. Server8 of Type-1:
900 - testbedname: testbed3.
902 - CIMC IP: 10.30.50.26
903 - Host IP: 10.30.51.26
905 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
906 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
907 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
908 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
909 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
910 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
911 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
912 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
913 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
914 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
915 9. Server9 of Type-2:
916 - testbedname: testbed3.
918 - CIMC IP: 10.30.50.24
919 - Host IP: 10.30.51.24
921 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
922 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
923 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
924 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
925 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
926 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
927 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
928 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
929 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
930 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
931 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
932 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
935 #### 3-Node-Skylake (3n-skx) PROD
938 - ServerB11 [Type-B1]:
939 - testbedname: testbed31.
940 - hostname: s11-t31-sut1.
941 - IPMI IP: 10.30.50.43
942 - Host IP: 10.30.51.46
944 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
945 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
946 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
947 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
948 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
949 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
950 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
951 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
952 - ServerB12 [Type-B1]:
953 - testbedname: testbed31.
954 - hostname: s12-t31-sut2.
955 - IPMI IP: 10.30.50.44
956 - Host IP: 10.30.51.47
958 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
959 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
960 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
961 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
962 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
963 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
964 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
965 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
966 - ServerB13 [Type-B2]:
967 - testbedname: testbed31.
968 - hostname: s13-t31-tg1.
969 - IPMI IP: 10.30.50.45
970 - Host IP: 10.30.51.48
972 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
973 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
974 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
975 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
976 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
977 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
978 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
979 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
980 - ServerB14 [Type-B1]:
981 - testbedname: testbed32.
982 - hostname: s14-t32-sut1.
983 - IPMI IP: 10.30.50.55
984 - Host IP: 10.30.51.58
986 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
987 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
988 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
989 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
990 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
991 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
992 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
993 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
994 - ServerB15 [Type-B1]:
995 - testbedname: testbed32.
996 - hostname: s15-t32-sut2.
997 - IPMI IP: 10.30.50.56
998 - Host IP: 10.30.51.59
1000 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1001 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1002 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1003 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1004 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1005 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1006 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1007 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1008 - ServerB16 [Type-B2]:
1009 - testbedname: testbed32.
1010 - hostname: s16-t32-tg1.
1011 - IPMI IP: 10.30.50.57
1012 - Host IP: 10.30.51.60
1014 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1015 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1016 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1017 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1018 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1019 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1020 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1021 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1024 #### 3-Node-Rangeley (3n-rng) VERIFY
1026 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1029 - ServerB22 [Type-B5]:
1030 - testbedname: testbed35.
1031 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1032 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1033 - Host IP: 10.30.51.9
1035 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1036 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1038 - ServerB23 [Type-B5]:
1039 - testbedname: testbed35.
1040 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1041 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1042 - Host IP: 10.30.51.10
1044 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1045 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1047 - ServerB24 [Type-B5]:
1048 - testbedname: testbed35.
1049 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1050 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1051 - Host IP: 10.30.51.11
1053 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1054 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1058 #### 3-Node-Taishan (3n-tsh) WIP
1060 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1063 - ServerB17 [Type-B3]:
1064 - testbedname: testbed33.
1065 - hostname: s17-t33-sut1.
1066 - IPMI IP: 10.30.50.36
1067 - Host IP: 10.30.51.36
1069 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1070 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1071 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1072 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1073 - ServerB18 [Type-B3]:
1074 - testbedname: testbed33.
1075 - hostname: s18-t33-sut2.
1076 - IPMI IP: 10.30.50.37
1077 - Host IP: 10.30.51.37
1079 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1080 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1081 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1082 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1083 - ServerB19 [Type-B2]:
1084 - testbednames: testbed33 and testbed34.
1085 - hostname: s19-t33t34-tg1.
1086 - IPMI IP: 10.30.50.46
1087 - Host IP: 10.30.51.49
1089 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1090 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1091 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1092 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1093 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1094 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1095 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1096 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1097 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1098 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1099 - ServerB20 [Type-B4]:
1100 - testbedname: testbed34.
1101 - hostname: s20-t34-sut1.
1103 - Host IP: 10.30.51.41
1105 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1106 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1107 - ServerB21 [Type-B4]:
1108 - testbedname: testbed34.
1109 - hostname: s21-t34-sut2.
1111 - Host IP: 10.30.51.42
1113 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1114 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1117 #### 3-Node-Denverton (3n-dnv) WIP
1120 - ServerB30 [Type-B10]:
1121 - testbednames: testbed35.
1122 - hostname: s30-t35-sut1.
1123 - IPMI IP: 10.30.55.12
1124 - Host IP: 10.32.8.12
1126 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1127 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1128 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1129 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1130 - ServerB31 [Type-B10]:
1131 - testbednames: testbed35.
1132 - hostname: s31-t35-sut2.
1133 - IPMI IP: 10.30.55.13
1134 - Host IP: 10.32.8.13
1136 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1137 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1138 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1139 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1142 #### 3-Node-Mcbin (3n-mcb) TODO
1148 ### Per Testbed Wiring
1150 #### 1-Node-Skylake (1n-skx) PROD
1154 - ring1 10GE-ports x710-4p10GE:
1155 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1156 - ring2 10GE-ports x710-4p10GE:
1157 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1158 - ring3 10GE-ports x710-4p10GE:
1159 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1160 - ring4 10GE-ports x710-4p10GE:
1161 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1163 - ring1 10GE-ports x710-4p10GE:
1164 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1165 - ring2 10GE-ports x710-4p10GE:
1166 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1167 - ring3 10GE-ports x710-4p10GE:
1168 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1169 - ring4 10GE-ports x710-4p10GE:
1170 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1173 #### 1-Node-Thunderx2 (1n-tx2) WIP
1177 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1178 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1179 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1180 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1181 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1182 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1185 #### 2-Node-Skylake (2n-skx) PROD
1189 - ring1 10GE-ports x710-4p10GE on SUT:
1190 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1191 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1192 - ring2 10GE-ports x710-4p10GE on SUT:
1193 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1194 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1195 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1196 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1197 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1198 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1199 - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
1200 - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
1201 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1202 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1203 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1205 - ring1 10GE-ports x710-4p10GE on SUT:
1206 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1207 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1208 - ring2 10GE-ports x710-4p10GE on SUT:
1209 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1210 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1211 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1212 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1213 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1214 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1215 - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
1216 - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
1217 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1218 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1219 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1221 - ring1 10GE-ports x710-4p10GE on SUT:
1222 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1223 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1224 - ring2 10GE-ports x710-4p10GE on SUT:
1225 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1226 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1227 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1228 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1229 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1230 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1231 - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
1232 - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
1233 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1234 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1235 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1237 - ring1 10GE-ports x710-4p10GE on SUT:
1238 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1239 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1240 - ring2 10GE-ports x710-4p10GE on SUT:
1241 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1242 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1243 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1244 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1245 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1246 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1247 - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
1248 - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
1249 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1250 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1251 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1254 #### 2-Node-Denverton (2n-dnv) WIP
1258 - ring1 10GE-ports x553 copper port on SUT:
1259 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1260 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1261 - ring2 10GE-ports x553 fiber port on SUT:
1262 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1263 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1266 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
1270 - link1 10GE-port x710-4p10GE on SUT:
1271 - t25-tg1-p1 to t25-sut1-c2/p1.
1272 - link2 10GE-port x710-4p10GE on SUT:
1273 - t25-tg1-p2 to t25-sut1-c2/p2.
1274 - link3 10GE-port x710-4p10GE on SUT:
1275 - t25-tg1-p3 to t25-sut1-c2/p3.
1276 - link4 10GE-port x710-4p10GE on SUT:
1277 - t25-tg1-p4 to t25-sut1-c2/p4.
1280 #### 3-Node-Haswell (3n-hsw) PROD
1284 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1285 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1286 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1287 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1288 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1289 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1290 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1291 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1292 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1293 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1294 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1295 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1296 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1297 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1298 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1299 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1300 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1301 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1302 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1303 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1304 - TG loopback ports Intel NIC x710 2p10GE
1305 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1308 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1309 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1310 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1311 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1312 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1313 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1314 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1315 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1316 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1317 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1318 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1319 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1320 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1321 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1322 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1323 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1324 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1325 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1326 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1327 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1328 - TG loopback ports Intel NIC x710 2p10GE
1329 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1332 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1333 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1334 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1335 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1336 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1337 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1338 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1339 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1340 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1341 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1342 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1343 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1344 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1345 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1346 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1347 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1348 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1349 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1350 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1351 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1352 - TG loopback ports Intel NIC x710 2p10GE
1353 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1356 #### 3-Node-Skylake (3n-skx) PROD
1360 - ring1 10GE-ports x710-4p10GE on SUTs:
1361 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1362 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1363 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1364 - ring2 10GE-ports x710-4p10GE on SUT:
1365 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1366 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1367 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1368 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1369 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1370 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1371 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1372 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1373 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1374 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1375 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1376 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1377 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1378 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1380 - ring1 10GE-ports x710-4p10GE on SUTs:
1381 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1382 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1383 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1384 - ring2 10GE-ports x710-4p10GE on SUT:
1385 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1386 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1387 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1388 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1389 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1390 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1391 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1392 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1393 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1394 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1395 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1396 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1397 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1398 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1401 #### 3-Node-Rangeley (3n-rng) TODO
1407 #### 3-Node-Taishan (3n-tsh) WIP
1411 - ring1 10GE-ports x520-2p10GE on SUTs:
1412 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1413 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1414 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1415 - ring2 25GE-ports cx4-2p25GE on SUTs:
1416 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1417 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1418 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1421 #### 3-Node-Mcbin (3n-mcb) WIP
1425 - ring1 10GE-ports Marvell on SUTs:
1426 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1427 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1428 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1431 #### 3-Node-Denverton (3n-dnv) WIP
1435 - ring1 10GE-ports x553 copper port on SUTs:
1436 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1437 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1438 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1439 - ring2 10GE-ports x553 fiber port on SUTs:
1440 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1441 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1442 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1450 1. Ixia PerfectStorm One Appliance
1452 - Chassis: PS10GE4NG.
1453 - Motherboard: SuperMicro X11DPG-QT.
1454 - Processors: Quad-Core, Intel Processor.
1455 - HW accelerators: FPGA offload.
1457 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1458 - Physical Interfaces: 4 * 10GE SFP+.
1459 - Operating System: Native IxOS.
1465 1. Arm Cortex A-72 servers
1467 - Chassis: Marvell ThunderX2
1468 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1469 - RAM Memory: 4* 32GB RDIMM
1470 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1471 - 2 * Huawei TaiShan 2280.
1472 - Chassis: Huawei TaiShan 2280.
1473 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1474 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1475 - Disks: 1* 4TB SATA HDD.
1477 - Chassis: MACCHIATObin.
1478 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1479 - RAM Memory: 1* 16GB DDR4.
1480 - Disks: 1* 128GB(?) SATA SDD.
1483 ### Xeon and Atom Servers
1486 1. Intel Xeon servers:
1487 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1488 - Chassis: SuperMicro SYS-7049GP-TRT.
1489 - Motherboard: SuperMicro X11DPG-QT.
1490 - Processors: 2* Intel Platinum 8180 2.3 GHz.
1491 - RAM Memory: 16* 16GB DDR4-2666MHz.
1492 - Disks: 2* 1.6TB 6G SATA SSD.
1493 2. Intel Atom servers with Rangely processors.
1494 - 3 * Netgate XG-2758-1u
1495 - Chassis: Netgate XG-2758-1u
1496 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1497 - RAM Memory: 16GB ECC
1501 ### Network Interface Cards
1505 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1506 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1507 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1509 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1511 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1513 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1516 ### Pluggables and Cables
1522 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1523 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1529 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1540 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable