1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
17 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
30 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
35 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
36 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
37 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
43 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
72 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
74 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
75 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
76 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
77 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
78 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
79 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
80 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
84 13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
85 14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
86 Totals: 25 31 15 4 19 1 2 3 3 2 7 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
138 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
139 one TG (Server-Type-D2) connected in a 2-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
145 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
146 one TG (Server-Type-E31) connected in a 2-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
150 ### 3-Node-Haswell Xeon Intel (3n-hsw)
152 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
153 TG (Server-Type-A2) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
157 ### 3-Node-Skylake Xeon Intel (3n-skx)
159 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
160 TG (Server-Type-B2) connected in a 3-node circular topology.
161 Used for FD.io performance tests.
163 ### 3-Node-Rangeley Atom Testbeds
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
170 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
172 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
173 TG (Server-Type-E31) connected in a 3-node circular topology
174 ([Server Types](#server-types)).
175 Used for FD.io performance tests.
181 For management purposes, each server must have following two ports
182 connected to the management network:
186 - IPMI - Intelligent Platform Management Interface.
187 - Required for access to embedded server management with WebUI, CLI,
188 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
189 - 1GE/10GE/40GE management port
190 - hostOS management port for general system management.
195 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
196 Management port, which are connected to two different VLANs.
200 - Subnet: 10.30.50.0/24
201 - Gateway: 10.30.50.1
202 - Broadcast: 10.30.50.255
203 - DNS1: 199.204.44.24
204 - DNS2: 199.204.47.54
206 - Subnet: 10.30.51.0/24
207 - Gateway: 10.30.51.1
208 - Broadcast: 10.30.51.255
209 - DNS1: 199.204.44.24
210 - DNS2: 199.204.47.54
213 To access these hosts, VPN connection is required.
215 ### LOM (IPMI) VLAN IP Addresses
218 ------------ | -------
221 10.30.50.2 | LF Reserved
222 10.30.50.3 | LF Reserved
223 10.30.50.4 | LF Reserved
224 10.30.50.5 | LF Reserved
225 10.30.50.6 | LF Reserved
226 10.30.50.7 | LF Reserved
227 10.30.50.8 | LF Reserved
228 10.30.50.9 | LF Reserved
229 10.30.50.10 | LF Reserved
230 10.30.50.11 | LF Reserved
231 10.30.50.12 | LF Reserved
232 10.30.50.13 | LF Reserved
233 10.30.50.14 | LF Reserved
234 10.30.50.15 | LF Reserved
235 10.30.50.22 | s42-nomad
236 10.30.50.24 | s43-nomad
237 10.30.50.25 | s44-nomad
238 10.30.50.26 | s45-nomad
239 10.30.50.28 | s41-nomad
240 10.30.50.29 | s39-nomad
241 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
242 10.30.50.30 | s40-nomad
243 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
244 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
245 10.30.50.36 | s17-t33-sut1
246 10.30.50.37 | s18-t33-sut2
247 10.30.50.38 | fdio-marvell-dev
248 10.30.50.39 | s53-nomad
249 10.30.50.40 | s54-nomad
250 10.30.50.41 | s3-t21-sut1
251 10.30.50.42 | s4-t21-tg1
252 10.30.50.43 | s11-t31-sut1
253 10.30.50.44 | s12-t31-sut2
254 10.30.50.45 | s13-t31-tg1
255 10.30.50.46 | s19-t33t211-tg1
256 10.30.50.47 | s1-t11-sut1
257 10.30.50.48 | s2-t12-sut1
258 10.30.50.49 | s5-t22-sut1
259 10.30.50.50 | s6-t22-tg1
260 10.30.50.51 | s7-t23-sut1
261 10.30.50.52 | s8-t23-tg1
262 10.30.50.53 | s9-t24-sut1
263 10.30.50.54 | s10-t24-tg1
264 10.30.50.55 | s14-t32-sut1
265 10.30.50.56 | s15-t32-sut2
266 10.30.50.57 | s16-t32-tg1
267 10.30.50.58 | s25-t25-sut1
268 10.30.50.59 | s26-t25-tg1
269 10.30.50.65 | s52-nomad
270 10.30.50.66 | s51-nomad
271 10.30.50.67 | s49-nomad
272 10.30.50.68 | s50-nomad
273 10.30.50.69 | s27-t211-sut1
274 10.30.50.70 | s55-t13-sut1
275 10.30.50.71 | s56-t14-sut1
276 10.30.50.255 | Broadcast
279 10.30.55.10 | s28-t26t35-tg1
280 10.30.55.11 | s29-t26-sut1
281 10.30.55.12 | s30-t35-sut1
282 10.30.55.13 | s31-t35-sut2
283 10.30.55.14 | s46-nomad
284 10.30.55.15 | s47-nomad
285 10.30.55.16 | s48-nomad
286 10.30.55.17 | s57-nomad
287 10.30.55.18 | s33-t27-sut1
288 10.30.55.19 | s34-t27-tg1
289 10.30.55.20 | s35-t28-sut1
290 10.30.55.21 | s36-t28-tg1
291 10.30.55.22 | s37-t29-sut1
292 10.30.55.23 | s38-t29-tg1
293 10.30.55.24 | s60-t210-sut1
294 10.30.55.25 | s61-t210-tg1
295 10.30.55.255 | Broadcast
297 ### Management VLAN IP Addresses
300 ------------------------- | -------
303 10.30.51.2 | LF Reserved
304 10.30.51.3 | LF Reserved
305 10.30.51.4 | LF Reserved
306 10.30.51.5 | LF Reserved
307 10.30.51.6 | LF Reserved
308 10.30.51.7 | LF Reserved
309 10.30.51.8 | LF Reserved
310 10.30.51.15 | LF Reserved
311 10.30.51.22 | s42-nomad
312 10.30.51.24 | s43-nomad
313 10.30.51.25 | s44-nomad
314 10.30.51.26 | s45-nomad
315 10.30.51.28 | s41-nomad
316 10.30.51.29 | s39-nomad
317 10.30.51.30 | s40-nomad
318 10.30.51.36 | s17-t33-sut1
319 10.30.51.37 | s18-t33-sut2
320 10.30.51.38 | fdio-marvell-dev
321 10.30.51.39 | s53-nomad
322 10.30.51.40 | s54-nomad
323 10.30.51.44 | s3-t21-sut1
324 10.30.51.45 | s4-t21-tg1
325 10.30.51.46 | s11-t31-sut1
326 10.30.51.47 | s12-t31-sut2
327 10.30.51.48 | s13-t31-tg1
328 10.30.51.49 | s19-t33t211-tg1
329 10.30.51.50 | s1-t11-sut1
330 10.30.51.51 | s2-t12-sut1
331 10.30.51.52 | s5-t22-sut1
332 10.30.51.53 | s6-t22-tg1
333 10.30.51.54 | s7-t23-sut1
334 10.30.51.55 | s8-t23-tg1
335 10.30.51.56 | s9-t24-sut1
336 10.30.51.57 | s10-t24-tg1
337 10.30.51.58 | s14-t32-sut1
338 10.30.51.59 | s15-t32-sut2
339 10.30.51.60 | s16-t32-tg1
340 10.30.51.61 | s25-t25-sut1
341 10.30.51.62 | s26-t25-tg1
342 10.30.51.65 | s52-nomad
343 10.30.51.66 | s51-nomad
344 10.30.51.67 | s49-nomad
345 10.30.51.68 | s50-nomad
346 10.30.51.69 | s27-t211-sut1
347 10.30.51.70 | s55-t13-sut1
348 10.30.51.71 | s56-t14-sut1
349 10.30.51.72-10.30.51.254 | FREE
350 10.30.51.255 | Broadcast
353 10.32.8.10 | s28-t26t35-tg1
354 10.32.8.11 | s29-t26-sut1
355 10.32.8.12 | s30-t35-sut1
356 10.32.8.13 | s31-t35-sut2
357 10.32.8.14 | s46-nomad
358 10.32.8.15 | s47-nomad
359 10.32.8.16 | s48-nomad
360 10.32.8.17 | s57-nomad
361 10.32.8.18 | s33-t27-sut1
362 10.32.8.19 | s34-t27-tg1
363 10.32.8.20 | s35-t28-sut1
364 10.32.8.21 | s36-t28-tg1
365 10.32.8.22 | s37-t29-sut1
366 10.32.8.23 | s38-t29-tg1
367 10.32.8.24 | s60-t210-sut1
368 10.32.8.25 | s61-t210-tg1
369 10.32.8.255 | Broadcast
371 ## Server Specifications
375 FD.io CSIT lab contains following server types:
377 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
378 - Quantity: 6 servers.
379 - Physical connectivity:
380 - CIMC and host management ports.
381 - NIC ports connected in 3-node topologies.
382 - Main HW configuration:
383 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
384 - Processors: 2* E5-2699v3 2.3 GHz.
385 - RAM Memory: 16* 32GB DDR4-2133MHz.
386 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
387 - NICs configuration:
388 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
392 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
396 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
397 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
398 - Quantity: 3 servers.
399 - Physical connectivity:
400 - CIMC and host management ports.
401 - NIC ports connected in 3-node topologies.
402 - Main HW configuration:
403 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
404 - Processors: 2* E5-2699v3 2.3 GHz.
405 - RAM Memory: 16* 32GB DDR4-2133MHz.
406 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
407 - NICs configuration:
408 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
412 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
417 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
418 - Quantity: 3 servers.
419 - Physical connectivity:
420 - CIMC and host management ports.
421 - no NIC ports, standalone setup.
422 - Main HW configuration:
423 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
424 - Processors: 2* E5-2699v3 2.3 GHz.
425 - RAM Memory: 16* 32GB DDR4-2133MHz.
426 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
427 - NICs configuration:
428 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
430 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
433 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
435 - Physical connectivity:
436 - IPMI and host management ports.
437 - NIC ports connected into 2-node and 3-node topologies.
438 - Main HW configuration:
439 - Chassis: SuperMicro SYS-7049GP-TRT.
440 - Motherboard: SuperMicro X11DPG-QT.
441 - Processors: 2* Intel Platinum 8180 2.5 GHz.
442 - RAM Memory: 16* 16GB DDR4-2666MHz.
443 - Disks: 2* 1.6TB 6G SATA SSD.
444 - NICs configuration:
445 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
446 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
447 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
448 - PCIe Slot9 5e:00.xx: empty.
449 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
450 - PCIe Slot6 86:00.xx: empty.
451 - PCIe Slot8 af:00.xx: empty.
452 - PCIe Slot10 d8:00.xx: empty.
453 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
455 - Physical connectivity:
456 - IPMI and host management ports.
457 - NIC ports connected into 2-node and 3-node topologies.
458 - Main HW configuration:
459 - Chassis: SuperMicro SYS-7049GP-TRT.
460 - Motherboard: SuperMicro X11DPG-QT.
461 - Processors: 2* Intel Platinum 8180 2.5 GHz.
462 - RAM Memory: 16* 16GB DDR4-2666MHz.
463 - Disks: 2* 1.6TB 6G SATA SSD.
464 - NICs configuration:
465 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
466 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
467 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
468 - PCIe Slot9 5e:00.xx: empty.
469 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
470 - PCIe Slot6 86:00.xx: empty.
471 - PCIe Slot8 af:00.xx: empty.
472 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
473 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
474 - Quantity: TBD based on testbed allocation.
475 - Physical connectivity:
476 - Management: serial Port (usb) for console
477 - NIC ports connected into 2-node.
478 - Main HW configuration:
479 - Chassis: Netgate XG-2758-1u
480 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
481 - RAM Memory: 16GB ECC
483 - NICs configuration:
484 - 2x 10Gb Intel 82599ES
486 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
488 - Physical connectivity:
489 - IPMI and host management ports.
490 - NIC ports connected into 1-node topologies.
491 - Main HW configuration:
492 - Chassis: SuperMicro SYS-7049GP-TRT.
493 - Motherboard: SuperMicro X11DPG-QT.
494 - Processors: 2* Intel Platinum 8180 2.5 GHz.
495 - RAM Memory: 16* 16GB DDR4-2666MHz.
496 - Disks: 2* 1.6TB 6G SATA SSD.
497 - NICs configuration:
498 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
499 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
500 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
501 - PCIe Slot9 5e:00.xx: empty.
502 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
503 - PCIe Slot6 86:00.xx: empty.
504 - PCIe Slot8 af:00.xx: empty.
505 - PCIe Slot10 d8:00.xx: empty.
506 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
508 - Physical connectivity:
509 - Host management interface: 10/100/1000-BaseT.
510 - 8-port 10GE SFP+ integrated NIC.
511 - Main HW configuration:
512 - Chassis: PS10GE4NG.
513 - Motherboard: SuperMicro X11DPG-QT.
514 - Processors: Quad-Core, Intel Processor.
515 - HW accelerators: FPGA offload.
517 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
518 - Physical Interfaces: 4 * 10GE SFP+.
519 - Operating System: Native IxOS.
520 - Interface configuration:
525 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
527 - Physical connectivity:
528 - IPMI and host management ports.
530 - Main HW configuration:
531 - Chassis: SuperMicro SYS-7049GP-TRT.
532 - Motherboard: SuperMicro X11DPG-QT.
533 - Processors: 2* Intel Platinum 8180 2.5 GHz.
534 - RAM Memory: 16* 16GB DDR4-2666MHz.
535 - Disks: 2* 1.6TB 6G SATA SSD.
536 - NICs configuration:
537 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
538 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
539 - PCIe Slot4 3b:00.xx: empty.
540 - PCIe Slot9 5e:00.xx: empty.
541 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
542 - PCIe Slot6 86:00.xx: empty.
543 - PCIe Slot8 af:00.xx: empty.
544 - PCIe Slot10 d8:00.xx: empty.
545 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
547 - Physical connectivity:
548 - IPMI and host management ports.
550 - Main HW configuration:
551 - Chassis: SuperMicro SYS-E300-9A
552 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
553 - RAM Memory: 32GB ECC
555 - NICs configuration:
556 - 2x 10Gb Intel x553 fiber ports
557 - 2x 10Gb Intel x553 copper ports
558 - 4x 1GB Intel I350 ports
559 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
561 - Physical connectivity:
562 - IPMI and host management ports.
563 - NIC ports connected into 1-node testbed topologies.
564 - Main HW configuration:
565 - Chassis: SuperMicro SYS-7049GP-TRT.
566 - Motherboard: SuperMicro X11DPG-QT.
567 - Processors: 2* Intel Platinum 8280 2.7 GHz.
568 - RAM Memory: 12* 16GB DDR4-2933.
569 - Disks: 2* 1.92TB SATA SSD.
570 - NICs configuration:
571 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
572 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
573 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
574 - PCIe Slot9 5e:00.xx: empty.
575 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
576 - PCIe Slot6 86:00.xx: empty.
577 - PCIe Slot8 af:00.xx: empty.
578 - PCIe Slot10 d8:00.xx: empty.
579 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
581 - Physical connectivity:
582 - IPMI and host management ports.
583 - NIC ports connected into 2-node testbed topologies.
584 - Main HW configuration:
585 - Chassis: SuperMicro SYS-7049GP-TRT.
586 - Motherboard: SuperMicro X11DPG-QT.
587 - Processors: 2* Intel Gold 6252N 2.3 GHz.
588 - RAM Memory: 12* 16GB DDR4-2933.
589 - Disks: 2* 1.92TB SATA SSD.
590 - NICs configuration:
591 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
592 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
593 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
594 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
595 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
596 - PCIe Slot6 86:00.xx: empty.
597 - PCIe Slot8 af:00.xx: empty.
598 - PCIe Slot10 d8:00.xx: empty.
599 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
601 - Physical connectivity:
602 - IPMI and host management ports.
603 - NIC ports connected into 2-node testbed topologies.
604 - Main HW configuration:
605 - Chassis: SuperMicro SYS-7049GP-TRT.
606 - Motherboard: SuperMicro X11DPG-QT.
607 - Processors: 2* Intel Platinum 8280 2.7 GHz.
608 - RAM Memory: 12* 16GB DDR4-2933.
609 - Disks: 2* 1.92TB SATA SSD.
610 - NICs configuration:
611 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
612 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
613 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
614 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
615 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
616 - PCIe Slot6 86:00.xx: empty.
617 - PCIe Slot8 af:00.xx: empty.
618 - PCIe Slot10 d8:00.xx: empty.
619 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
621 - Physical connectivity:
622 - CIMC and host management ports.
623 - no NIC ports, standalone setup.
624 - Main HW configuration:
625 - Chassis: SuperMicro 1029P-WTRT.
626 - Motherboard: SuperMicro X11DDW-NT.
627 - Processors: 2* Intel Platinum 8280 2.7 GHz.
628 - RAM Memory: 12* 16GB DDR4-2933.
629 - Disks: 4* 1.92TB SATA SSD.
630 - NICs configuration:
635 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
637 - Physical connectivity:
638 - IPMI and host management ports.
639 - NIC ports connected into 2-node testbed topologies.
640 - Main HW configuration:
641 - Chassis: SuperMicro AS-1114S-WTRT
642 - Processors: 1* AMD EPYC 7532 2.4 GHz.
643 - RAM Memory: 8* 32GB DDR4-2933.
644 - Disks: 1* 1TB SATA SSD.
645 - NICs configuration:
646 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
647 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
648 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
649 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
650 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
652 - Physical connectivity:
653 - IPMI and host management ports.
654 - NIC ports connected into 2-node testbed topologies.
655 - Main HW configuration:
656 - Chassis: SuperMicro AS-1114S-WTRT
657 - Processors: 1* AMD EPYC 7532 2.4 GHz.
658 - RAM Memory: 8* 32GB DDR4-2933.
659 - Disks: 1* 1TB SATA SSD.
660 - NICs configuration:
661 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
662 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
663 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
664 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
665 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
667 - Physical connectivity:
668 - IPMI and host management ports.
669 - NIC ports connected into 1-node topologies.
670 - Main HW configuration:
671 - Chassis: GIGABYTE Rack Mount
672 - Motherboard: MT91-FS4-00
673 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
674 - RAM Memory: 16 * 16GB DIMM
675 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
676 - NICs configuration:
678 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
679 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
681 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
682 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
683 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
685 - Physical connectivity:
686 - IPMI(?) and host management ports.
687 - NIC ports connected into 3-node topology.
688 - Main HW configuration:
689 - Chassis: Huawei TaiShan 2280.
690 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
691 - RAM Memory: 8* 16GB DDR4-2400MT/s
692 - Disks: 1* 4TB SATA HDD
693 - NICs configuration:
694 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
695 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
696 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
698 - Physical connectivity:
699 - IPMI and host management ports.
700 - NIC ports connected into 2-node topologies.
701 - Main HW configuration:
702 - Chassis: Gigabyte R181-T90 1U
703 - Motherboard: MT91-FS1
704 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
705 - RAM Memory: 4* 32GB RDIMM
706 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
707 - NICs configuration:
709 - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
711 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
712 20. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
714 - Physical connectivity:
715 - IPMI and host management ports.
716 - NIC ports connected into 2-node and 3-node topologies.
717 - Main HW configuration:
718 - Chassis: SuperMicro SYS-7049GP-TRT.
719 - Motherboard: SuperMicro X11DPG-QT.
720 - Processors: 2* Intel Platinum 8180 2.5 GHz.
721 - RAM Memory: 16* 16GB DDR4-2666MHz.
722 - Disks: 2* 1.6TB 6G SATA SSD.
723 - NICs configuration:
724 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
725 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
726 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
727 - PCIe Slot9 5e:00.xx: empty.
728 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
729 - PCIe Slot6 86:00.xx: empty.
730 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
731 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
734 ### Naming Convention
736 Following naming convention is used within this page to specify physical
737 connectivity and wiring across defined CSIT testbeds:
740 - testbedname: testbedN.
742 - traffic-generator: tN-tgW.
743 - system-under-testX: tN-sutX.
748 - N - testbed number.
749 - tgW - server acts as traffic-generator with W index.
750 - sutX - server acts as system-under-test with X index.
751 - Y - PCIe slot number denoting a NIC card number within the host.
752 - Z - port number on the NIC card.
755 ## Testbeds Configuration
757 ### Per Testbed Server Allocation and Naming
759 #### 1-Node-Skylake Servers (1n-skx) PROD
762 - SUT [Server-Type-B6]:
763 - testbedname: testbed11.
764 - hostname: s1-t11-sut1.
765 - IPMI IP: 10.30.50.47
766 - Host IP: 10.30.51.50
768 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
769 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
770 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
771 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
772 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
773 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
774 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
775 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
776 - SUT [Server-Type-B6]:
777 - testbedname: testbed12.
778 - hostname: s2-t12-sut1.
779 - IPMI IP: 10.30.50.48
780 - Host IP: 10.30.51.51
782 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
783 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
784 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
785 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
786 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
787 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
788 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
789 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
792 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
795 - SUT [Server-Type-E11]:
796 - testbedname: testbed13
797 - hostname: s55-t13-sut1
798 - IPMI IP: 10.30.50.70
799 - Host IP: 10.30.51.70
801 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
802 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
803 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
804 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
805 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
806 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
807 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
808 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
809 - SUT [Server-Type-E11]:
810 - testbedname: testbed14
811 - hostname: s56-t14-sut1
812 - IPMI IP: 10.30.50.71
813 - Host IP: 10.30.51.71
815 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
816 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
817 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
818 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
819 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
820 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
821 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
822 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
825 #### 1-Node-Cascadelake Servers (1n-clx) PROD
828 - SUT [Server-Type-C1]:
829 - testbedname: testbed11.
830 - hostname: s32-t14-sut1.
831 - IPMI IP: 10.30.55.17
832 - Host IP: 10.32.8.17
834 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
835 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
836 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
837 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
838 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
839 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
840 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
841 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
844 #### 2-Node-Skylake Servers (2n-skx) PROD
847 - SUT [Server-Type-B1]:
848 - testbedname: testbed21.
849 - hostname: s3-t21-sut1.
850 - IPMI IP: 10.30.50.41
851 - Host IP: 10.30.51.44
853 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
854 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
855 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
856 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
857 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
858 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
859 - TG [Server-Type-B2]:
860 - testbedname: testbed21.
861 - hostname: s4-t21-tg1.
862 - IPMI IP: 10.30.50.42
863 - Host IP: 10.30.51.45
865 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
866 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
867 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
868 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
869 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
870 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
871 - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
872 - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
873 - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
874 - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
875 - SUT [Server-Type-B1]:
876 - testbedname: testbed22.
877 - hostname: s5-t22-sut1.
878 - IPMI IP: 10.30.50.49
879 - Host IP: 10.30.51.52
881 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
882 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
883 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
884 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
885 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
886 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
887 - TG [Server-Type-B2]:
888 - testbedname: testbed22.
889 - hostname: s6-t22-tg1.
890 - IPMI IP: 10.30.50.50
891 - Host IP: 10.30.51.53
893 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
894 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
895 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
896 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
897 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
898 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
899 - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
900 - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
901 - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
902 - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
903 - SUT [Server-Type-B1]:
904 - testbedname: testbed23.
905 - hostname: s7-t23-sut1.
906 - IPMI IP: 10.30.50.51
907 - Host IP: 10.30.51.54
909 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
910 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
911 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
912 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
913 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
914 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
915 - TG [Server-Type-B2]:
916 - testbedname: testbed23.
917 - hostname: s8-t23-tg1.
918 - IPMI IP: 10.30.50.52
919 - Host IP: 10.30.51.55
921 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
922 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
923 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
924 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
925 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
926 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
927 - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
928 - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
929 - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
930 - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
931 - SUT [Server-Type-B1]:
932 - testbedname: testbed24.
933 - hostname: s9-t24-sut1.
934 - IPMI IP: 10.30.50.53
935 - Host IP: 10.30.51.56
937 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
938 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
939 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
940 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
941 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
942 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
943 - TG [Server-Type-B2]:
944 - testbedname: testbed24.
945 - hostname: s10-t24-tg1.
946 - IPMI IP: 10.30.50.54
947 - Host IP: 10.30.51.57
949 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
950 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
951 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
952 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
953 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
954 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
955 - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
956 - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
957 - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
958 - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
961 #### 2-Node-Denverton Servers (2n-dnv) PROD
963 Note: ServerB28 (TG) is shared between testbed26 & testbed35
966 - TG [Server-Type-B2]:
967 - testbednames: testbed26 and testbed35.
968 - hostname: s28-t26t35-tg1.
969 - IPMI IP: 10.30.55.10
970 - Host IP: 10.32.8.10
972 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
973 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
974 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
975 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
976 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
977 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
978 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
979 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
980 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
981 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
982 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
983 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
984 - SUT [Server-Type-B10]:
985 - testbednames: testbed26.
986 - hostname: s29-t26-sut1.
987 - IPMI IP: 10.30.55.11
988 - Host IP: 10.32.8.11
990 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
991 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
992 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
993 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
996 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
999 - SUT [Server-Type-B8]:
1000 - testbedname: testbed25.
1001 - hostname: s25-t25-sut1.
1002 - IPMI IP: 10.30.50.58
1003 - Host IP: 10.30.51.61
1005 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1006 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1007 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1008 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1009 - TG [Server-Type-B7]:
1010 - testbedname: testbed25.
1011 - hostname: s26-t25-tg1.
1012 - IPMI IP: 10.30.50.59
1013 - Host IP: 10.30.51.62
1015 - s26-t25-tg1-p1 - 10GE-port1.
1016 - s26-t25-tg1-p2 - 10GE-port2.
1017 - s26-t25-tg1-p3 - 10GE-port3.
1018 - s26-t25-tg1-p4 - 10GE-port4.
1021 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1024 - SUT [Server-Type-C2]:
1025 - testbedname: testbed27.
1026 - hostname: s33-t27-sut1.
1027 - IPMI IP: 10.30.55.18
1028 - Host IP: 10.32.8.18
1030 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1031 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1032 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1033 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1034 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1035 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1036 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1037 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1038 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1039 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1040 - TG [Server-Type-C3]:
1041 - testbedname: testbed27.
1042 - hostname: s34-t27-tg1.
1043 - IPMI IP: 10.30.55.19
1044 - Host IP: 10.32.8.19
1046 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1047 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1048 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1049 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1050 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1051 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1052 - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1053 - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1054 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1055 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1056 - SUT [Server-Type-C2]:
1057 - testbedname: testbed28.
1058 - hostname: s35-t28-sut1.
1059 - IPMI IP: 10.30.55.20
1060 - Host IP: 10.32.8.20
1062 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1063 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1064 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1065 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1066 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1067 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1068 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1069 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1070 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1071 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1072 - TG [Server-Type-C3]:
1073 - testbedname: testbed28.
1074 - hostname: s36-t28-tg1.
1075 - IPMI IP: 10.30.55.21
1076 - Host IP: 10.32.8.21
1078 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1079 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1080 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1081 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1082 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1083 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1084 - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1085 - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1086 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1087 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1088 - SUT [Server-Type-C2]:
1089 - testbedname: testbed29.
1090 - hostname: s37-t29-sut1.
1091 - IPMI IP: 10.30.55.22
1092 - Host IP: 10.32.8.22
1094 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1095 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1096 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1097 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1098 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1099 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1100 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1101 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1102 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1103 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1104 - TG [Server-Type-C3]:
1105 - testbedname: testbed29.
1106 - hostname: s38-t29-tg1.
1107 - IPMI IP: 10.30.55.23
1108 - Host IP: 10.32.8.23
1110 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1111 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1112 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1113 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1114 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1115 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1116 - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1117 - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1118 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1119 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1122 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1125 - SUT [Server-Type-D1]:
1126 - testbedname: testbed210.
1127 - hostname: s60-t210-sut1.
1128 - IPMI IP: 10.30.55.24
1129 - Host IP: 10.32.8.24
1131 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1132 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1133 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1134 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1135 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1138 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1139 - TG [Server-Type-D2]:
1140 - testbedname: testbed210.
1141 - hostname: s61-t210-tg1.
1142 - IPMI IP: 10.30.55.25
1143 - Host IP: 10.32.8.25
1145 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1146 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1147 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1148 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1149 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1150 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1151 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1152 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1155 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1157 Note: Server19 (TG) is shared between testbed33 & testbed211
1160 - SUT [Server-Type-E22]:
1161 - testbedname: testbed211.
1162 - hostname: s27-t211-sut1.
1163 - IPMI IP: 10.30.50.69
1164 - Host IP: 10.30.51.69
1166 - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1167 - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1168 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1169 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1170 - TG [Server-Type-E31]:
1171 - testbedname: testbed33 and testbed211.
1172 - hostname: s19-t33t211-tg1.
1173 - IPMI IP: 10.30.50.46
1174 - Host IP: 10.30.51.49
1176 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1177 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1178 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1179 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1180 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1181 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1182 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1183 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1184 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1185 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1186 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1187 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1190 #### 3-Node-Skylake Servers (3n-skx) PROD
1193 - ServerB11 [Server-Type-B1]:
1194 - testbedname: testbed31.
1195 - hostname: s11-t31-sut1.
1196 - IPMI IP: 10.30.50.43
1197 - Host IP: 10.30.51.46
1199 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1200 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1201 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1202 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1203 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1204 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1205 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1206 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1207 - ServerB12 [Server-Type-B1]:
1208 - testbedname: testbed31.
1209 - hostname: s12-t31-sut2.
1210 - IPMI IP: 10.30.50.44
1211 - Host IP: 10.30.51.47
1213 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1214 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1215 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1216 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1217 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1220 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1221 - ServerB13 [Server-Type-B2]:
1222 - testbedname: testbed31.
1223 - hostname: s13-t31-tg1.
1224 - IPMI IP: 10.30.50.45
1225 - Host IP: 10.30.51.48
1227 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1228 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1229 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1230 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1231 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1232 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1233 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1234 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1235 - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1236 - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1237 - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1238 - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1239 - ServerB14 [Server-Type-B1]:
1240 - testbedname: testbed32.
1241 - hostname: s14-t32-sut1.
1242 - IPMI IP: 10.30.50.55
1243 - Host IP: 10.30.51.58
1245 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1246 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1247 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1248 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1249 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1250 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1251 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1252 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1253 - ServerB15 [Server-Type-B1]:
1254 - testbedname: testbed32.
1255 - hostname: s15-t32-sut2.
1256 - IPMI IP: 10.30.50.56
1257 - Host IP: 10.30.51.59
1259 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1260 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1261 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1262 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1263 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1264 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1265 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1266 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1267 - ServerB16 [Server-Type-B2]:
1268 - testbedname: testbed32.
1269 - hostname: s16-t32-tg1.
1270 - IPMI IP: 10.30.50.57
1271 - Host IP: 10.30.51.60
1273 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1274 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1275 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1276 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1277 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1278 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1279 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1280 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1281 - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1282 - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1283 - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1284 - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1287 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1289 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1292 - ServerB22 [Server-Type-B5]:
1293 - testbedname: testbed35.
1294 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1295 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1296 - Host IP: 10.30.51.9
1298 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1299 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1301 - ServerB23 [Server-Type-B5]:
1302 - testbedname: testbed35.
1303 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1304 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1305 - Host IP: 10.30.51.10
1307 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1308 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1310 - ServerB24 [Server-Type-B5]:
1311 - testbedname: testbed35.
1312 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1313 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1314 - Host IP: 10.30.51.11
1316 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1317 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1321 #### 3-Node-Taishan Servers (3n-tsh) PROD
1323 Note: Server19 (TG) is shared between testbed33 & testbed211
1326 - SUT [Server-Type-E21]:
1327 - testbedname: testbed33.
1328 - hostname: s17-t33-sut1.
1329 - IPMI IP: 10.30.50.36
1330 - Host IP: 10.30.51.36
1332 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1333 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1334 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1335 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1336 - SUT [Server-Type-E21]:
1337 - testbedname: testbed33.
1338 - hostname: s18-t33-sut2.
1339 - IPMI IP: 10.30.50.37
1340 - Host IP: 10.30.51.37
1342 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1343 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1344 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1345 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1346 - TG [Server-Type-E31]:
1347 - testbedname: testbed33 and testbed211.
1348 - hostname: s19-t33t211-tg1.
1349 - IPMI IP: 10.30.50.46
1350 - Host IP: 10.30.51.49
1352 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1353 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1354 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1355 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1356 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1357 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1358 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1359 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1360 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1361 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1362 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1363 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1366 #### 3-Node-Denverton Servers (3n-dnv) PROD
1369 - ServerB30 [Server-Type-B10]:
1370 - testbednames: testbed35.
1371 - hostname: s30-t35-sut1.
1372 - IPMI IP: 10.30.55.12
1373 - Host IP: 10.32.8.12
1375 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1376 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1377 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1378 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1379 - ServerB31 [Server-Type-B10]:
1380 - testbednames: testbed35.
1381 - hostname: s31-t35-sut2.
1382 - IPMI IP: 10.30.55.13
1383 - Host IP: 10.32.8.13
1385 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1386 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1387 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1388 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1391 ### Per Testbed Wiring
1393 #### 1-Node-Skylake Wiring (1n-skx) PROD
1397 - ring1 10GE-ports x710-4p10GE:
1398 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1399 - ring2 10GE-ports x710-4p10GE:
1400 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1401 - ring3 10GE-ports x710-4p10GE:
1402 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1403 - ring4 10GE-ports x710-4p10GE:
1404 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1405 - ring5 100GE-ports e810-2p100GE:
1406 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1407 - ring6 100GE-ports e810-2p100GE:
1408 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1410 - ring1 10GE-ports x710-4p10GE:
1411 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1412 - ring2 10GE-ports x710-4p10GE:
1413 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1414 - ring3 10GE-ports x710-4p10GE:
1415 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1416 - ring4 10GE-ports x710-4p10GE:
1417 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1418 - ring5 100GE-ports e810-2p100GE:
1419 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1420 - ring6 100GE-ports e810-2p100GE:
1421 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1424 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1428 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1429 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1430 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1431 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1432 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1433 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1434 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1435 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1438 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1439 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1440 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1441 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1442 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1443 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1444 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1445 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1448 #### 2-Node-Skylake Wiring (2n-skx) PROD
1452 - ring1 10GE-ports x710-4p10GE on SUT:
1453 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1454 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1455 - ring2 10GE-ports x710-4p10GE on SUT:
1456 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1457 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1458 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1459 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1460 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1461 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1462 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1463 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1465 - ring1 10GE-ports x710-4p10GE on SUT:
1466 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1467 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1468 - ring2 10GE-ports x710-4p10GE on SUT:
1469 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1470 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1471 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1472 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1473 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1474 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1475 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1476 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1478 - ring1 10GE-ports x710-4p10GE on SUT:
1479 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1480 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1481 - ring2 10GE-ports x710-4p10GE on SUT:
1482 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1483 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1484 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1485 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1486 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1487 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1488 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1489 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1491 - ring1 10GE-ports x710-4p10GE on SUT:
1492 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1493 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1494 - ring2 10GE-ports x710-4p10GE on SUT:
1495 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1496 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1497 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1498 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1499 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1500 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1501 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1502 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1505 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1509 - ring1 10GE-ports x553 copper port on SUT:
1510 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1511 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1512 - ring2 10GE-ports x553 fiber port on SUT:
1513 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1514 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1517 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1521 - link1 10GE-port x710-4p10GE on SUT:
1522 - t25-tg1-p1 to t25-sut1-c2/p1.
1523 - link2 10GE-port x710-4p10GE on SUT:
1524 - t25-tg1-p2 to t25-sut1-c2/p2.
1525 - link3 10GE-port x710-4p10GE on SUT:
1526 - t25-tg1-p3 to t25-sut1-c2/p3.
1527 - link4 10GE-port x710-4p10GE on SUT:
1528 - t25-tg1-p4 to t25-sut1-c2/p4.
1531 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1535 - ring1 10GE-ports x710-4p10GE on SUT:
1536 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1537 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1538 - ring2 10GE-ports x710-4p10GE on SUT:
1539 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1540 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1541 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1542 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1543 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1544 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1545 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1546 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1547 - ring5 100GE-ports e810-2p100GE on SUT:
1548 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1549 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1551 - ring1 10GE-ports x710-4p10GE on SUT:
1552 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1553 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1554 - ring2 10GE-ports x710-4p10GE on SUT:
1555 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1556 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1557 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1558 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1559 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1560 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1561 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1562 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1563 - ring5 100GE-ports e810-2p100GE on SUT:
1564 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1565 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1567 - ring1 10GE-ports x710-4p10GE on SUT:
1568 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1569 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1570 - ring2 10GE-ports x710-4p10GE on SUT:
1571 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1572 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1573 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1574 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1575 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1576 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1577 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1578 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1579 - ring6 100GE-ports e810-2p100GE on SUT:
1580 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1581 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1584 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1588 - ring1 10GE-ports x710-4p10GE on SUT:
1589 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1590 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1591 - ring2 10GE-ports x710-4p10GE on SUT:
1592 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1593 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1594 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1595 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1596 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1597 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1598 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1599 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1602 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1606 - ring1 10GE-ports x520-2p10GE on SUTs:
1607 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1608 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1611 #### 3-Node-Skylake Wiring (3n-skx) PROD
1615 - ring1 10GE-ports x710-4p10GE on SUTs:
1616 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1617 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1618 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1619 - ring2 10GE-ports x710-4p10GE on SUT:
1620 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1621 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1622 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1623 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1624 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1625 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1626 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1627 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1628 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1629 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1630 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1631 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1632 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1633 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1635 - ring1 10GE-ports x710-4p10GE on SUTs:
1636 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1637 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1638 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1639 - ring2 10GE-ports x710-4p10GE on SUT:
1640 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1641 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1642 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1643 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1644 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1645 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1646 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1647 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1648 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1649 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1650 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1651 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1652 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1653 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1656 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1662 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1666 - ring1 10GE-ports x520-2p10GE on SUTs:
1667 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1668 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1669 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1670 - ring2 25GE-ports cx4-2p25GE on SUTs:
1671 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1672 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1673 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1676 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1680 - ring1 10GE-ports x553 copper port on SUTs:
1681 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1682 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1683 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1684 - ring2 10GE-ports x553 fiber port on SUTs:
1685 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1686 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1687 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1695 1. Ixia PerfectStorm One Appliance
1697 - Chassis: PS10GE4NG.
1698 - Motherboard: SuperMicro X11DPG-QT.
1699 - Processors: Quad-Core, Intel Processor.
1700 - HW accelerators: FPGA offload.
1702 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1703 - Physical Interfaces: 4 * 10GE SFP+.
1704 - Operating System: Native IxOS.
1710 1. Arm Cortex A-72 servers
1711 - 2 * ThunderX2 (VPP Device)
1712 - Chassis: GIGABYTE Rack Mount
1713 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1714 - RAM Memory: 16* 16GB DIMM
1715 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1716 - 1 * ThunderX2 (Performance)
1717 - Chassis: GIGABYTE Rack Mount
1718 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1719 - RAM Memory: 4* 32GB RDIMM
1720 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1721 - 2 * Huawei TaiShan 2280.
1722 - Chassis: Huawei TaiShan 2280.
1723 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1724 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1725 - Disks: 1* 4TB SATA HDD.
1728 ### Xeon and Atom Servers
1731 1. Intel Xeon servers:
1732 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1733 - Chassis: SuperMicro SYS-7049GP-TRT.
1734 - Motherboard: SuperMicro X11DPG-QT.
1735 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1736 - RAM Memory: 16* 16GB DDR4-2666MHz.
1737 - Disks: 2* 1.6TB 6G SATA SSD.
1738 2. Intel Atom servers with Rangely processors.
1739 - 3 * Netgate XG-2758-1u
1740 - Chassis: Netgate XG-2758-1u
1741 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1742 - RAM Memory: 16GB ECC
1746 ### Network Interface Cards
1750 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1751 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1752 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1754 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1756 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1758 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1761 ### Pluggables and Cables
1767 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1768 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1774 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1785 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable