1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
30 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
35 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
36 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
37 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
43 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
72 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
74 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
75 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
76 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
77 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
78 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
79 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
80 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
84 13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
85 14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
86 Totals: 25 31 15 4 19 1 2 3 3 2 7 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
138 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
139 one TG (Server-Type-D2) connected in a 2-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
145 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
146 one TG (Server-Type-B12) connected in a 2-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
150 ### 3-Node-Haswell Xeon Intel (3n-hsw)
152 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
153 TG (Server-Type-A2) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
157 ### 3-Node-Skylake Xeon Intel (3n-skx)
159 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
160 TG (Server-Type-B2) connected in a 3-node circular topology.
161 Used for FD.io performance tests.
163 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
165 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
166 TG (Server-Type-B12) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
170 ### 3-Node-Rangeley Atom Testbeds
172 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
173 TG (Server-Type-2) connected in a 3-node circular topology
174 ([Server Types](#server-types)).
175 Used for FD.io performance tests.
181 For management purposes, each server must have following two ports
182 connected to the management network:
186 - IPMI - Intelligent Platform Management Interface.
187 - Required for access to embedded server management with WebUI, CLI,
188 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
189 - 1GE/10GE/40GE management port
190 - hostOS management port for general system management.
195 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
196 Management port, which are connected to two different VLANs.
200 - Subnet: 10.30.50.0/24
201 - Gateway: 10.30.50.1
202 - Broadcast: 10.30.50.255
203 - DNS1: 199.204.44.24
204 - DNS2: 199.204.47.54
206 - Subnet: 10.30.51.0/24
207 - Gateway: 10.30.51.1
208 - Broadcast: 10.30.51.255
209 - DNS1: 199.204.44.24
210 - DNS2: 199.204.47.54
213 To access these hosts, VPN connection is required.
215 ### LOM (IPMI) VLAN IP Addresses
218 ------------ | -------
221 10.30.50.2 | LF Reserved
222 10.30.50.3 | LF Reserved
223 10.30.50.4 | LF Reserved
224 10.30.50.5 | LF Reserved
225 10.30.50.6 | LF Reserved
226 10.30.50.7 | LF Reserved
227 10.30.50.8 | LF Reserved
228 10.30.50.9 | LF Reserved
229 10.30.50.10 | LF Reserved
230 10.30.50.11 | LF Reserved
231 10.30.50.12 | LF Reserved
232 10.30.50.13 | LF Reserved
233 10.30.50.14 | LF Reserved
234 10.30.50.15 | LF Reserved
235 10.30.50.22 | s42-nomad
236 10.30.50.24 | s43-nomad
237 10.30.50.25 | s44-nomad
238 10.30.50.26 | s45-nomad
239 10.30.50.28 | s41-nomad
240 10.30.50.29 | s39-nomad
241 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
242 10.30.50.30 | s40-nomad
243 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
244 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
245 10.30.50.36 | s17-t33-sut1
246 10.30.50.37 | s18-t33-sut2
247 10.30.50.38 | fdio-marvell-dev
248 10.30.50.39 | s53-nomad
249 10.30.50.40 | s54-nomad
250 10.30.50.41 | s3-t21-sut1
251 10.30.50.42 | s4-t21-tg1
252 10.30.50.43 | s11-t31-sut1
253 10.30.50.44 | s12-t31-sut2
254 10.30.50.45 | s13-t31-tg1
255 10.30.50.46 | s19-t33t34-tg1
256 10.30.50.47 | s1-t11-sut1
257 10.30.50.48 | s2-t12-sut1
258 10.30.50.49 | s5-t22-sut1
259 10.30.50.50 | s6-t22-tg1
260 10.30.50.51 | s7-t23-sut1
261 10.30.50.52 | s8-t23-tg1
262 10.30.50.53 | s9-t24-sut1
263 10.30.50.54 | s10-t24-tg1
264 10.30.50.55 | s14-t32-sut1
265 10.30.50.56 | s15-t32-sut2
266 10.30.50.57 | s16-t32-tg1
267 10.30.50.58 | s25-t25-sut1
268 10.30.50.59 | s26-t25-tg1
269 10.30.50.65 | s52-nomad
270 10.30.50.66 | s51-nomad
271 10.30.50.67 | s49-nomad
272 10.30.50.68 | s50-nomad
273 10.30.50.69 | s27-t34-sut1
274 10.30.50.70 | s55-t36-sut1
275 10.30.50.71 | s56-t37-sut1
276 10.30.50.255 | Broadcast
281 10.30.55.10 | s28-t26t35-tg1
282 10.30.55.11 | s29-t26-sut1
283 10.30.55.12 | s30-t35-sut1
284 10.30.55.13 | s31-t35-sut2
285 10.30.55.14 | s46-nomad
286 10.30.55.15 | s47-nomad
287 10.30.55.16 | s48-nomad
288 10.30.55.17 | s57-nomad
289 10.30.55.18 | s33-t27-sut1
290 10.30.55.19 | s34-t27-tg1
291 10.30.55.20 | s35-t28-sut1
292 10.30.55.21 | s36-t28-tg1
293 10.30.55.22 | s37-t29-sut1
294 10.30.55.23 | s38-t29-tg1
295 10.30.55.24 | s60-t210-sut1
296 10.30.55.25 | s61-t210-tg1
297 10.30.55.255 | Broadcast
299 ### Management VLAN IP Addresses
302 ------------------------- | -------
305 10.30.51.2 | LF Reserved
306 10.30.51.3 | LF Reserved
307 10.30.51.4 | LF Reserved
308 10.30.51.5 | LF Reserved
309 10.30.51.6 | LF Reserved
310 10.30.51.7 | LF Reserved
311 10.30.51.8 | LF Reserved
312 10.30.51.15 | LF Reserved
313 10.30.51.22 | s42-nomad
314 10.30.51.24 | s43-nomad
315 10.30.51.25 | s44-nomad
316 10.30.51.26 | s45-nomad
317 10.30.51.28 | s41-nomad
318 10.30.51.29 | s39-nomad
319 10.30.51.30 | s40-nomad
320 10.30.51.36 | s17-t33-sut1
321 10.30.51.37 | s18-t33-sut2
322 10.30.51.38 | fdio-marvell-dev
323 10.30.51.39 | s53-nomad
324 10.30.51.40 | s54-nomad
325 10.30.51.44 | s3-t21-sut1
326 10.30.51.45 | s4-t21-tg1
327 10.30.51.46 | s11-t31-sut1
328 10.30.51.47 | s12-t31-sut2
329 10.30.51.48 | s13-t31-tg1
330 10.30.51.49 | s19-t33t34-tg1
331 10.30.51.50 | s1-t11-sut1
332 10.30.51.51 | s2-t12-sut1
333 10.30.51.52 | s5-t22-sut1
334 10.30.51.53 | s6-t22-tg1
335 10.30.51.54 | s7-t23-sut1
336 10.30.51.55 | s8-t23-tg1
337 10.30.51.56 | s9-t24-sut1
338 10.30.51.57 | s10-t24-tg1
339 10.30.51.58 | s14-t32-sut1
340 10.30.51.59 | s15-t32-sut2
341 10.30.51.60 | s16-t32-tg1
342 10.30.51.61 | s25-t25-sut1
343 10.30.51.62 | s26-t25-tg1
344 10.30.51.65 | s52-nomad
345 10.30.51.66 | s51-nomad
346 10.30.51.67 | s49-nomad
347 10.30.51.68 | s50-nomad
348 10.30.51.69 | s27-t34-sut1
349 10.30.51.70 | s55-t36-sut1
350 10.30.51.71 | s56-t37-sut1
351 10.30.51.72-10.30.51.254 | FREE
352 10.30.51.255 | Broadcast
355 10.32.8.10 | s28-t26t35-tg1
356 10.32.8.11 | s29-t26-sut1
357 10.32.8.12 | s30-t35-sut1
358 10.32.8.13 | s31-t35-sut2
359 10.32.8.14 | s46-nomad
360 10.32.8.15 | s47-nomad
361 10.32.8.16 | s48-nomad
362 10.32.8.17 | s57-nomad
363 10.32.8.18 | s33-t27-sut1
364 10.32.8.19 | s34-t27-tg1
365 10.32.8.20 | s35-t28-sut1
366 10.32.8.21 | s36-t28-tg1
367 10.32.8.22 | s37-t29-sut1
368 10.32.8.23 | s38-t29-tg1
369 10.32.8.24 | s60-t210-sut1
370 10.32.8.25 | s61-t210-tg1
371 10.32.8.255 | Broadcast
373 ## Server Specifications
377 FD.io CSIT lab contains following server types:
379 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
380 - Quantity: 6 servers.
381 - Physical connectivity:
382 - CIMC and host management ports.
383 - NIC ports connected in 3-node topologies.
384 - Main HW configuration:
385 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
386 - Processors: 2* E5-2699v3 2.3 GHz.
387 - RAM Memory: 16* 32GB DDR4-2133MHz.
388 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
389 - NICs configuration:
390 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
394 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
398 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
399 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
400 - Quantity: 3 servers.
401 - Physical connectivity:
402 - CIMC and host management ports.
403 - NIC ports connected in 3-node topologies.
404 - Main HW configuration:
405 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
406 - Processors: 2* E5-2699v3 2.3 GHz.
407 - RAM Memory: 16* 32GB DDR4-2133MHz.
408 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
409 - NICs configuration:
410 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
414 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
419 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
420 - Quantity: 3 servers.
421 - Physical connectivity:
422 - CIMC and host management ports.
423 - no NIC ports, standalone setup.
424 - Main HW configuration:
425 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
426 - Processors: 2* E5-2699v3 2.3 GHz.
427 - RAM Memory: 16* 32GB DDR4-2133MHz.
428 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
429 - NICs configuration:
430 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
432 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
435 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
437 - Physical connectivity:
438 - IPMI and host management ports.
439 - NIC ports connected into 2-node and 3-node topologies.
440 - Main HW configuration:
441 - Chassis: SuperMicro SYS-7049GP-TRT.
442 - Motherboard: SuperMicro X11DPG-QT.
443 - Processors: 2* Intel Platinum 8180 2.5 GHz.
444 - RAM Memory: 16* 16GB DDR4-2666MHz.
445 - Disks: 2* 1.6TB 6G SATA SSD.
446 - NICs configuration:
447 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
448 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
449 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
450 - PCIe Slot9 5e:00.xx: empty.
451 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
452 - PCIe Slot6 86:00.xx: empty.
453 - PCIe Slot8 af:00.xx: empty.
454 - PCIe Slot10 d8:00.xx: empty.
455 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
457 - Physical connectivity:
458 - IPMI and host management ports.
459 - NIC ports connected into 2-node and 3-node topologies.
460 - Main HW configuration:
461 - Chassis: SuperMicro SYS-7049GP-TRT.
462 - Motherboard: SuperMicro X11DPG-QT.
463 - Processors: 2* Intel Platinum 8180 2.5 GHz.
464 - RAM Memory: 16* 16GB DDR4-2666MHz.
465 - Disks: 2* 1.6TB 6G SATA SSD.
466 - NICs configuration:
467 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
468 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
469 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
470 - PCIe Slot9 5e:00.xx: empty.
471 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
472 - PCIe Slot6 86:00.xx: empty.
473 - PCIe Slot8 af:00.xx: empty.
474 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
475 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
477 - Physical connectivity:
478 - IPMI(?) and host management ports.
479 - NIC ports connected into 3-node topology.
480 - Main HW configuration:
481 - Chassis: Huawei TaiShan 2280.
482 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
483 - RAM Memory: 8* 16GB DDR4-2400MT/s
484 - Disks: 1* 4TB SATA HDD
485 - NICs configuration:
486 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
487 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
488 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
489 - Quantity: TBD based on testbed allocation.
490 - Physical connectivity:
491 - Management: serial Port (usb) for console
492 - NIC ports connected into 2-node.
493 - Main HW configuration:
494 - Chassis: Netgate XG-2758-1u
495 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
496 - RAM Memory: 16GB ECC
498 - NICs configuration:
499 - 2x 10Gb Intel 82599ES
501 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
503 - Physical connectivity:
504 - IPMI and host management ports.
505 - NIC ports connected into 1-node topologies.
506 - Main HW configuration:
507 - Chassis: SuperMicro SYS-7049GP-TRT.
508 - Motherboard: SuperMicro X11DPG-QT.
509 - Processors: 2* Intel Platinum 8180 2.5 GHz.
510 - RAM Memory: 16* 16GB DDR4-2666MHz.
511 - Disks: 2* 1.6TB 6G SATA SSD.
512 - NICs configuration:
513 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
514 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
515 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
516 - PCIe Slot9 5e:00.xx: empty.
517 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
518 - PCIe Slot6 86:00.xx: empty.
519 - PCIe Slot8 af:00.xx: empty.
520 - PCIe Slot10 d8:00.xx: empty.
521 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
523 - Physical connectivity:
524 - Host management interface: 10/100/1000-BaseT.
525 - 8-port 10GE SFP+ integrated NIC.
526 - Main HW configuration:
527 - Chassis: PS10GE4NG.
528 - Motherboard: SuperMicro X11DPG-QT.
529 - Processors: Quad-Core, Intel Processor.
530 - HW accelerators: FPGA offload.
532 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
533 - Physical Interfaces: 4 * 10GE SFP+.
534 - Operating System: Native IxOS.
535 - Interface configuration:
540 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
542 - Physical connectivity:
543 - IPMI and host management ports.
545 - Main HW configuration:
546 - Chassis: SuperMicro SYS-7049GP-TRT.
547 - Motherboard: SuperMicro X11DPG-QT.
548 - Processors: 2* Intel Platinum 8180 2.5 GHz.
549 - RAM Memory: 16* 16GB DDR4-2666MHz.
550 - Disks: 2* 1.6TB 6G SATA SSD.
551 - NICs configuration:
552 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
553 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
554 - PCIe Slot4 3b:00.xx: empty.
555 - PCIe Slot9 5e:00.xx: empty.
556 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
557 - PCIe Slot6 86:00.xx: empty.
558 - PCIe Slot8 af:00.xx: empty.
559 - PCIe Slot10 d8:00.xx: empty.
560 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
562 - Physical connectivity:
563 - IPMI and host management ports.
564 - NIC ports connected into 1-node topologies.
565 - Main HW configuration:
566 - Chassis: Gigabyte R181-T90 1U
567 - Motherboard: MT91-FS1
568 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
569 - RAM Memory: 4* 32GB RDIMM
570 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
571 - NICs configuration:
573 - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
575 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
576 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
578 - Physical connectivity:
579 - IPMI and host management ports.
581 - Main HW configuration:
582 - Chassis: SuperMicro SYS-E300-9A
583 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
584 - RAM Memory: 32GB ECC
586 - NICs configuration:
587 - 2x 10Gb Intel x553 fiber ports
588 - 2x 10Gb Intel x553 copper ports
589 - 4x 1GB Intel I350 ports
590 13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
592 - Physical connectivity:
593 - IPMI and host management ports.
594 - NIC ports connected into 1-node topologies.
595 - Main HW configuration:
596 - Chassis: GIGABYTE Rack Mount
597 - Motherboard: MT91-FS4-00
598 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
599 - RAM Memory: 16 * 16GB DIMM
600 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
601 - NICs configuration:
603 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
604 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
606 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
607 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
608 14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
610 - Physical connectivity:
611 - IPMI and host management ports.
612 - NIC ports connected into 2-node and 3-node topologies.
613 - Main HW configuration:
614 - Chassis: SuperMicro SYS-7049GP-TRT.
615 - Motherboard: SuperMicro X11DPG-QT.
616 - Processors: 2* Intel Platinum 8180 2.5 GHz.
617 - RAM Memory: 16* 16GB DDR4-2666MHz.
618 - Disks: 2* 1.6TB 6G SATA SSD.
619 - NICs configuration:
620 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
621 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
622 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
623 - PCIe Slot9 5e:00.xx: empty.
624 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
625 - PCIe Slot6 86:00.xx: empty.
626 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
627 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
629 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
631 - Physical connectivity:
632 - IPMI and host management ports.
633 - NIC ports connected into 1-node testbed topologies.
634 - Main HW configuration:
635 - Chassis: SuperMicro SYS-7049GP-TRT.
636 - Motherboard: SuperMicro X11DPG-QT.
637 - Processors: 2* Intel Platinum 8280 2.7 GHz.
638 - RAM Memory: 12* 16GB DDR4-2933.
639 - Disks: 2* 1.92TB SATA SSD.
640 - NICs configuration:
641 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
642 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
643 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
644 - PCIe Slot9 5e:00.xx: empty.
645 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
646 - PCIe Slot6 86:00.xx: empty.
647 - PCIe Slot8 af:00.xx: empty.
648 - PCIe Slot10 d8:00.xx: empty.
649 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
651 - Physical connectivity:
652 - IPMI and host management ports.
653 - NIC ports connected into 2-node testbed topologies.
654 - Main HW configuration:
655 - Chassis: SuperMicro SYS-7049GP-TRT.
656 - Motherboard: SuperMicro X11DPG-QT.
657 - Processors: 2* Intel Gold 6252N 2.3 GHz.
658 - RAM Memory: 12* 16GB DDR4-2933.
659 - Disks: 2* 1.92TB SATA SSD.
660 - NICs configuration:
661 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
662 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
663 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
664 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
665 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
666 - PCIe Slot6 86:00.xx: empty.
667 - PCIe Slot8 af:00.xx: empty.
668 - PCIe Slot10 d8:00.xx: empty.
669 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
671 - Physical connectivity:
672 - IPMI and host management ports.
673 - NIC ports connected into 2-node testbed topologies.
674 - Main HW configuration:
675 - Chassis: SuperMicro SYS-7049GP-TRT.
676 - Motherboard: SuperMicro X11DPG-QT.
677 - Processors: 2* Intel Platinum 8280 2.7 GHz.
678 - RAM Memory: 12* 16GB DDR4-2933.
679 - Disks: 2* 1.92TB SATA SSD.
680 - NICs configuration:
681 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
682 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
683 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
684 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
685 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
686 - PCIe Slot6 86:00.xx: empty.
687 - PCIe Slot8 af:00.xx: empty.
688 - PCIe Slot10 d8:00.xx: empty.
689 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
691 - Physical connectivity:
692 - CIMC and host management ports.
693 - no NIC ports, standalone setup.
694 - Main HW configuration:
695 - Chassis: SuperMicro 1029P-WTRT.
696 - Motherboard: SuperMicro X11DDW-NT.
697 - Processors: 2* Intel Platinum 8280 2.7 GHz.
698 - RAM Memory: 12* 16GB DDR4-2933.
699 - Disks: 4* 1.92TB SATA SSD.
700 - NICs configuration:
705 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
707 - Physical connectivity:
708 - IPMI and host management ports.
709 - NIC ports connected into 2-node testbed topologies.
710 - Main HW configuration:
711 - Chassis: SuperMicro AS-1114S-WTRT
712 - Processors: 1* AMD EPYC 7532 2.4 GHz.
713 - RAM Memory: 8* 32GB DDR4-2933.
714 - Disks: 1* 1TB SATA SSD.
715 - NICs configuration:
716 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
717 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
718 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
719 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
720 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
722 - Physical connectivity:
723 - IPMI and host management ports.
724 - NIC ports connected into 2-node testbed topologies.
725 - Main HW configuration:
726 - Chassis: SuperMicro AS-1114S-WTRT
727 - Processors: 1* AMD EPYC 7532 2.4 GHz.
728 - RAM Memory: 8* 32GB DDR4-2933.
729 - Disks: 1* 1TB SATA SSD.
730 - NICs configuration:
731 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
732 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
733 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
734 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
737 ### Naming Convention
739 Following naming convention is used within this page to specify physical
740 connectivity and wiring across defined CSIT testbeds:
743 - testbedname: testbedN.
745 - traffic-generator: tN-tgW.
746 - system-under-testX: tN-sutX.
751 - N - testbed number.
752 - tgW - server acts as traffic-generator with W index.
753 - sutX - server acts as system-under-test with X index.
754 - Y - PCIe slot number denoting a NIC card number within the host.
755 - Z - port number on the NIC card.
758 ## Testbeds Configuration
760 ### Per Testbed Server Allocation and Naming
762 #### 1-Node-Skylake Servers (1n-skx) PROD
765 - SUT [Server-Type-B6]:
766 - testbedname: testbed11.
767 - hostname: s1-t11-sut1.
768 - IPMI IP: 10.30.50.47
769 - Host IP: 10.30.51.50
771 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
772 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
773 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
774 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
775 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
776 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
777 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
778 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
779 - SUT [Server-Type-B6]:
780 - testbedname: testbed12.
781 - hostname: s2-t12-sut1.
782 - IPMI IP: 10.30.50.48
783 - Host IP: 10.30.51.51
785 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
786 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
787 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
788 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
789 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
790 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
791 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
792 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
795 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
798 - SUT [Server-Type-B11]:
799 - testbedname: testbed36
800 - hostname: s55-t36-sut1
801 - IPMI IP: 10.30.50.70
802 - Host IP: 10.30.51.70
804 - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
805 - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
806 - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
807 - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
808 - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
809 - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
810 - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
811 - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
812 - SUT [Server-Type-B11]:
813 - testbedname: testbed37
814 - hostname: s56-t37-sut1
815 - IPMI IP: 10.30.50.71
816 - Host IP: 10.30.51.71
818 - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
819 - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
820 - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
821 - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
822 - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
823 - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
824 - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
825 - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
828 #### 1-Node-Cascadelake Servers (1n-clx) PROD
831 - SUT [Server-Type-C1]:
832 - testbedname: testbed11.
833 - hostname: s32-t14-sut1.
834 - IPMI IP: 10.30.55.17
835 - Host IP: 10.32.8.17
837 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
838 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
839 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
840 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
841 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
842 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
843 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
844 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
847 #### 2-Node-Skylake Servers (2n-skx) PROD
850 - SUT [Server-Type-B1]:
851 - testbedname: testbed21.
852 - hostname: s3-t21-sut1.
853 - IPMI IP: 10.30.50.41
854 - Host IP: 10.30.51.44
856 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
857 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
858 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
859 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
860 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
861 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
862 - TG [Server-Type-B2]:
863 - testbedname: testbed21.
864 - hostname: s4-t21-tg1.
865 - IPMI IP: 10.30.50.42
866 - Host IP: 10.30.51.45
868 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
869 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
870 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
871 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
872 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
873 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
874 - SUT [Server-Type-B1]:
875 - testbedname: testbed22.
876 - hostname: s5-t22-sut1.
877 - IPMI IP: 10.30.50.49
878 - Host IP: 10.30.51.52
880 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
881 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
882 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
883 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
884 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
885 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
886 - TG [Server-Type-B2]:
887 - testbedname: testbed22.
888 - hostname: s6-t22-tg1.
889 - IPMI IP: 10.30.50.50
890 - Host IP: 10.30.51.53
892 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
893 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
894 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
895 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
896 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
897 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
898 - SUT [Server-Type-B1]:
899 - testbedname: testbed23.
900 - hostname: s7-t23-sut1.
901 - IPMI IP: 10.30.50.51
902 - Host IP: 10.30.51.54
904 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
905 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
906 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
907 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
908 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
909 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
910 - TG [Server-Type-B2]:
911 - testbedname: testbed23.
912 - hostname: s8-t23-tg1.
913 - IPMI IP: 10.30.50.52
914 - Host IP: 10.30.51.55
916 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
917 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
918 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
919 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
920 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
921 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
922 - SUT [Server-Type-B1]:
923 - testbedname: testbed24.
924 - hostname: s9-t24-sut1.
925 - IPMI IP: 10.30.50.53
926 - Host IP: 10.30.51.56
928 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
929 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
930 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
931 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
932 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
933 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934 - TG [Server-Type-B2]:
935 - testbedname: testbed24.
936 - hostname: s10-t24-tg1.
937 - IPMI IP: 10.30.50.54
938 - Host IP: 10.30.51.57
940 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
941 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
942 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
943 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
944 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
945 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
948 #### 2-Node-Denverton Servers (2n-dnv) PROD
950 Note: ServerB28 (TG) is shared between testbed26 & testbed35
953 - TG [Server-Type-B2]:
954 - testbednames: testbed26 and testbed35.
955 - hostname: s28-t26t35-tg1.
956 - IPMI IP: 10.30.55.10
957 - Host IP: 10.32.8.10
959 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
960 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
961 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
962 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
963 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
964 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
965 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
966 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
967 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
968 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
969 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
970 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
971 - SUT [Server-Type-B10]:
972 - testbednames: testbed26.
973 - hostname: s29-t26-sut1.
974 - IPMI IP: 10.30.55.11
975 - Host IP: 10.32.8.11
977 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
978 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
979 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
980 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
983 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
986 - SUT [Server-Type-B8]:
987 - testbedname: testbed25.
988 - hostname: s25-t25-sut1.
989 - IPMI IP: 10.30.50.58
990 - Host IP: 10.30.51.61
992 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
993 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
994 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
995 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
996 - TG [Server-Type-B7]:
997 - testbedname: testbed25.
998 - hostname: s26-t25-tg1.
999 - IPMI IP: 10.30.50.59
1000 - Host IP: 10.30.51.62
1002 - s26-t25-tg1-p1 - 10GE-port1.
1003 - s26-t25-tg1-p2 - 10GE-port2.
1004 - s26-t25-tg1-p3 - 10GE-port3.
1005 - s26-t25-tg1-p4 - 10GE-port4.
1008 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1011 - SUT [Server-Type-C2]:
1012 - testbedname: testbed27.
1013 - hostname: s33-t27-sut1.
1014 - IPMI IP: 10.30.55.18
1015 - Host IP: 10.32.8.18
1017 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1018 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1019 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1020 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1021 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1022 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1023 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1024 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1025 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1026 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1027 - TG [Server-Type-C3]:
1028 - testbedname: testbed27.
1029 - hostname: s34-t27-tg1.
1030 - IPMI IP: 10.30.55.19
1031 - Host IP: 10.32.8.19
1033 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1034 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1035 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1036 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1037 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1038 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1039 - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1040 - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1041 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1042 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1043 - SUT [Server-Type-C2]:
1044 - testbedname: testbed28.
1045 - hostname: s35-t28-sut1.
1046 - IPMI IP: 10.30.55.20
1047 - Host IP: 10.32.8.20
1049 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1050 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1051 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1052 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1053 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1054 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1055 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1056 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1057 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1058 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1059 - TG [Server-Type-C3]:
1060 - testbedname: testbed28.
1061 - hostname: s36-t28-tg1.
1062 - IPMI IP: 10.30.55.21
1063 - Host IP: 10.32.8.21
1065 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1066 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1067 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1068 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1069 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1070 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1071 - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1072 - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1073 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1074 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1075 - SUT [Server-Type-C2]:
1076 - testbedname: testbed29.
1077 - hostname: s37-t29-sut1.
1078 - IPMI IP: 10.30.55.22
1079 - Host IP: 10.32.8.22
1081 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1082 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1083 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1084 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1085 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1086 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1087 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1088 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1089 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1090 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1091 - TG [Server-Type-C3]:
1092 - testbedname: testbed29.
1093 - hostname: s38-t29-tg1.
1094 - IPMI IP: 10.30.55.23
1095 - Host IP: 10.32.8.23
1097 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1098 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1099 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1100 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1101 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1102 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1103 - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1104 - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1105 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1106 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1109 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1112 - SUT [Server-Type-D1]:
1113 - testbedname: testbed210.
1114 - hostname: s60-t210-sut1.
1115 - IPMI IP: 10.30.55.24
1116 - Host IP: 10.32.8.24
1118 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1119 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1120 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1121 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1122 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1123 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1124 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1125 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1126 - TG [Server-Type-D2]:
1127 - testbedname: testbed210.
1128 - hostname: s61-t210-tg1.
1129 - IPMI IP: 10.30.55.25
1130 - Host IP: 10.32.8.25
1132 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1133 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1134 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1135 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1136 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1137 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1138 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1139 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1142 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1144 Note: Server19 (TG) is shared between testbed33 & testbed34
1147 - SUT [Server-Type-B9]:
1148 - testbedname: testbed34.
1149 - hostname: s27-t34-sut1.
1150 - IPMI IP: 10.30.50.69
1151 - Host IP: 10.30.51.69
1153 - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1154 - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1155 - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1156 - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1157 - TG [Server-Type-B12]:
1158 - testbedname: testbed33 and testbed34.
1159 - hostname: s19-t33t34-tg1.
1160 - IPMI IP: 10.30.50.46
1161 - Host IP: 10.30.51.49
1163 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1164 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1165 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1166 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1167 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1168 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1169 - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1170 - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1171 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1172 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1173 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1174 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1177 #### 3-Node-Skylake Servers (3n-skx) PROD
1180 - ServerB11 [Server-Type-B1]:
1181 - testbedname: testbed31.
1182 - hostname: s11-t31-sut1.
1183 - IPMI IP: 10.30.50.43
1184 - Host IP: 10.30.51.46
1186 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1187 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1188 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1189 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1190 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1191 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1192 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1193 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1194 - ServerB12 [Server-Type-B1]:
1195 - testbedname: testbed31.
1196 - hostname: s12-t31-sut2.
1197 - IPMI IP: 10.30.50.44
1198 - Host IP: 10.30.51.47
1200 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1201 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1202 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1203 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1204 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1205 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1206 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1207 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1208 - ServerB13 [Server-Type-B2]:
1209 - testbedname: testbed31.
1210 - hostname: s13-t31-tg1.
1211 - IPMI IP: 10.30.50.45
1212 - Host IP: 10.30.51.48
1214 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1215 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1216 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1217 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1218 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1219 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1220 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1221 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1222 - ServerB14 [Server-Type-B1]:
1223 - testbedname: testbed32.
1224 - hostname: s14-t32-sut1.
1225 - IPMI IP: 10.30.50.55
1226 - Host IP: 10.30.51.58
1228 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1229 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1230 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1231 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1232 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1233 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1234 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1235 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1236 - ServerB15 [Server-Type-B1]:
1237 - testbedname: testbed32.
1238 - hostname: s15-t32-sut2.
1239 - IPMI IP: 10.30.50.56
1240 - Host IP: 10.30.51.59
1242 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1243 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1244 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1245 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1246 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1247 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1248 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1249 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1250 - ServerB16 [Server-Type-B2]:
1251 - testbedname: testbed32.
1252 - hostname: s16-t32-tg1.
1253 - IPMI IP: 10.30.50.57
1254 - Host IP: 10.30.51.60
1256 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1257 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1258 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1259 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1260 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1261 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1262 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1263 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1266 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1268 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1271 - ServerB22 [Server-Type-B5]:
1272 - testbedname: testbed35.
1273 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1274 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1275 - Host IP: 10.30.51.9
1277 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1278 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1280 - ServerB23 [Server-Type-B5]:
1281 - testbedname: testbed35.
1282 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1283 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1284 - Host IP: 10.30.51.10
1286 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1287 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1289 - ServerB24 [Server-Type-B5]:
1290 - testbedname: testbed35.
1291 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1292 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1293 - Host IP: 10.30.51.11
1295 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1296 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1300 #### 3-Node-Taishan Servers (3n-tsh) PROD
1302 Note: Server19 (TG) is shared between testbed33 & testbed34
1305 - SUT [Server-Type-B3]:
1306 - testbedname: testbed33.
1307 - hostname: s17-t33-sut1.
1308 - IPMI IP: 10.30.50.36
1309 - Host IP: 10.30.51.36
1311 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1312 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1313 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1314 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1315 - SUT [Server-Type-B3]:
1316 - testbedname: testbed33.
1317 - hostname: s18-t33-sut2.
1318 - IPMI IP: 10.30.50.37
1319 - Host IP: 10.30.51.37
1321 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1322 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1323 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1324 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1325 - TG [Server-Type-B12]:
1326 - testbedname: testbed33 and testbed34.
1327 - hostname: s19-t33t34-tg1.
1328 - IPMI IP: 10.30.50.46
1329 - Host IP: 10.30.51.49
1331 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1332 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1333 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1334 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1335 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1336 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1337 - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1338 - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1339 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1340 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1341 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1342 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1345 #### 3-Node-Denverton Servers (3n-dnv) PROD
1348 - ServerB30 [Server-Type-B10]:
1349 - testbednames: testbed35.
1350 - hostname: s30-t35-sut1.
1351 - IPMI IP: 10.30.55.12
1352 - Host IP: 10.32.8.12
1354 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1355 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1356 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1357 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1358 - ServerB31 [Server-Type-B10]:
1359 - testbednames: testbed35.
1360 - hostname: s31-t35-sut2.
1361 - IPMI IP: 10.30.55.13
1362 - Host IP: 10.32.8.13
1364 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1365 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1366 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1367 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1370 ### Per Testbed Wiring
1372 #### 1-Node-Skylake Wiring (1n-skx) PROD
1376 - ring1 10GE-ports x710-4p10GE:
1377 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1378 - ring2 10GE-ports x710-4p10GE:
1379 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1380 - ring3 10GE-ports x710-4p10GE:
1381 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1382 - ring4 10GE-ports x710-4p10GE:
1383 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1384 - ring5 100GE-ports e810-2p100GE:
1385 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1386 - ring6 100GE-ports e810-2p100GE:
1387 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1389 - ring1 10GE-ports x710-4p10GE:
1390 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1391 - ring2 10GE-ports x710-4p10GE:
1392 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1393 - ring3 10GE-ports x710-4p10GE:
1394 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1395 - ring4 10GE-ports x710-4p10GE:
1396 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1397 - ring5 100GE-ports e810-2p100GE:
1398 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1399 - ring6 100GE-ports e810-2p100GE:
1400 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1403 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1407 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1408 - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1409 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1410 - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1411 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1412 - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1413 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1414 - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1417 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1418 - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1419 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1420 - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1421 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1422 - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1423 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1424 - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1427 #### 1-Node-Cascadelake Wiring (1n-clx) PROD
1431 - ring1 10GE-ports x710-4p10GE:
1432 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1433 - ring2 10GE-ports x710-4p10GE:
1434 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1435 - ring3 10GE-ports x710-4p10GE:
1436 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1437 - ring4 10GE-ports x710-4p10GE:
1438 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1441 #### 2-Node-Skylake Wiring (2n-skx) PROD
1445 - ring1 10GE-ports x710-4p10GE on SUT:
1446 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1447 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1448 - ring2 10GE-ports x710-4p10GE on SUT:
1449 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1450 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1451 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1452 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1453 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1455 - ring1 10GE-ports x710-4p10GE on SUT:
1456 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1457 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1458 - ring2 10GE-ports x710-4p10GE on SUT:
1459 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1460 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1461 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1462 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1463 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1465 - ring1 10GE-ports x710-4p10GE on SUT:
1466 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1467 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1468 - ring2 10GE-ports x710-4p10GE on SUT:
1469 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1470 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1471 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1472 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1473 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1475 - ring1 10GE-ports x710-4p10GE on SUT:
1476 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1477 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1478 - ring2 10GE-ports x710-4p10GE on SUT:
1479 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1480 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1481 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1482 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1483 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1486 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1490 - ring1 10GE-ports x553 copper port on SUT:
1491 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1492 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1493 - ring2 10GE-ports x553 fiber port on SUT:
1494 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1495 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1498 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1502 - link1 10GE-port x710-4p10GE on SUT:
1503 - t25-tg1-p1 to t25-sut1-c2/p1.
1504 - link2 10GE-port x710-4p10GE on SUT:
1505 - t25-tg1-p2 to t25-sut1-c2/p2.
1506 - link3 10GE-port x710-4p10GE on SUT:
1507 - t25-tg1-p3 to t25-sut1-c2/p3.
1508 - link4 10GE-port x710-4p10GE on SUT:
1509 - t25-tg1-p4 to t25-sut1-c2/p4.
1512 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1516 - ring1 10GE-ports x710-4p10GE on SUT:
1517 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1518 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1519 - ring2 10GE-ports x710-4p10GE on SUT:
1520 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1521 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1522 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1523 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1524 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1525 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1526 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1527 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1528 - ring5 100GE-ports e810-2p100GE on SUT:
1529 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1530 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1532 - ring1 10GE-ports x710-4p10GE on SUT:
1533 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1534 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1535 - ring2 10GE-ports x710-4p10GE on SUT:
1536 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1537 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1538 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1539 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1540 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1541 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1542 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1543 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1544 - ring5 100GE-ports e810-2p100GE on SUT:
1545 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1546 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1548 - ring1 10GE-ports x710-4p10GE on SUT:
1549 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1550 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1551 - ring2 10GE-ports x710-4p10GE on SUT:
1552 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1553 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1554 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1555 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1556 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1557 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1558 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1559 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1560 - ring6 100GE-ports e810-2p100GE on SUT:
1561 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1562 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1565 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1569 - ring1 10GE-ports x710-4p10GE on SUT:
1570 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1571 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1572 - ring2 10GE-ports x710-4p10GE on SUT:
1573 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1574 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1575 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1576 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1577 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1578 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1579 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1580 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1583 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1587 - ring1 10GE-ports x520-2p10GE on SUTs:
1588 - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
1589 - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
1592 #### 3-Node-Skylake Wiring (3n-skx) PROD
1596 - ring1 10GE-ports x710-4p10GE on SUTs:
1597 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1598 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1599 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1600 - ring2 10GE-ports x710-4p10GE on SUT:
1601 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1602 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1603 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1604 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1605 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1606 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1607 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1608 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1609 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1610 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1611 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1612 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1613 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1614 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1616 - ring1 10GE-ports x710-4p10GE on SUTs:
1617 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1618 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1619 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1620 - ring2 10GE-ports x710-4p10GE on SUT:
1621 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1622 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1623 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1624 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1625 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1626 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1627 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1628 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1629 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1630 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1631 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1632 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1633 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1634 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1637 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1643 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1647 - ring1 10GE-ports x520-2p10GE on SUTs:
1648 - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1649 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1650 - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1651 - ring2 25GE-ports cx4-2p25GE on SUTs:
1652 - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1653 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1654 - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1657 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1661 - ring1 10GE-ports x553 copper port on SUTs:
1662 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1663 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1664 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1665 - ring2 10GE-ports x553 fiber port on SUTs:
1666 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1667 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1668 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1676 1. Ixia PerfectStorm One Appliance
1678 - Chassis: PS10GE4NG.
1679 - Motherboard: SuperMicro X11DPG-QT.
1680 - Processors: Quad-Core, Intel Processor.
1681 - HW accelerators: FPGA offload.
1683 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1684 - Physical Interfaces: 4 * 10GE SFP+.
1685 - Operating System: Native IxOS.
1691 1. Arm Cortex A-72 servers
1692 - 2 * ThunderX2 (VPP Device)
1693 - Chassis: GIGABYTE Rack Mount
1694 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1695 - RAM Memory: 16* 16GB DIMM
1696 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1697 - 1 * ThunderX2 (Performance)
1698 - Chassis: GIGABYTE Rack Mount
1699 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1700 - RAM Memory: 4* 32GB RDIMM
1701 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1702 - 2 * Huawei TaiShan 2280.
1703 - Chassis: Huawei TaiShan 2280.
1704 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1705 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1706 - Disks: 1* 4TB SATA HDD.
1709 ### Xeon and Atom Servers
1712 1. Intel Xeon servers:
1713 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1714 - Chassis: SuperMicro SYS-7049GP-TRT.
1715 - Motherboard: SuperMicro X11DPG-QT.
1716 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1717 - RAM Memory: 16* 16GB DDR4-2666MHz.
1718 - Disks: 2* 1.6TB 6G SATA SSD.
1719 2. Intel Atom servers with Rangely processors.
1720 - 3 * Netgate XG-2758-1u
1721 - Chassis: Netgate XG-2758-1u
1722 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1723 - RAM Memory: 16GB ECC
1727 ### Network Interface Cards
1731 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1732 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1733 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1735 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1737 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1739 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1742 ### Pluggables and Cables
1748 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1749 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1755 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1766 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable