1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
74 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
75 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
76 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
77 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
78 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
79 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
80 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
84 13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
85 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
86 Totals: 22 35 18 12 19 1 2 3 1 2 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
156 ### 3-Node-MACCHIATObin Arm Marvell
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
163 ### 3-Node-Rangeley Atom Testbeds
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
174 For management purposes, each server must have following two ports
175 connected to the management network:
179 - IPMI - Intelligent Platform Management Interface.
180 - Required for access to embedded server management with WebUI, CLI,
181 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183 - hostOS management port for general system management.
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
193 - Subnet: 10.30.50.0/24
194 - Gateway: 10.30.50.1
195 - Broadcast: 10.30.50.255
196 - DNS1: 199.204.44.24
197 - DNS2: 199.204.47.54
199 - Subnet: 10.30.51.0/24
200 - Gateway: 10.30.51.1
201 - Broadcast: 10.30.51.255
202 - DNS1: 199.204.44.24
203 - DNS2: 199.204.47.54
206 To access these hosts, VPN connection is required.
208 ### LOM (IPMI) VLAN IP Addresses
211 ------------ | -------
214 10.30.50.2 | LF Reserved
215 10.30.50.3 | LF Reserved
216 10.30.50.4 | LF Reserved
217 10.30.50.5 | LF Reserved
218 10.30.50.6 | LF Reserved
219 10.30.50.7 | LF Reserved
220 10.30.50.8 | LF Reserved
221 10.30.50.9 | LF Reserved
222 10.30.50.10 | LF Reserved
223 10.30.50.11 | LF Reserved
224 10.30.50.12 | LF Reserved
225 10.30.50.13 | LF Reserved
226 10.30.50.14 | LF Reserved
227 10.30.50.15 | LF Reserved
229 10.30.50.17 | t1-sut1
230 10.30.50.18 | t1-sut2
232 10.30.50.21 | t2-sut1
233 10.30.50.22 | t2-sut2
235 10.30.50.25 | t3-sut1
236 10.30.50.26 | t3-sut-2
237 10.30.50.28 | s41-nomad
238 10.30.50.29 | s39-nomad
239 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30 | s40-nomad
241 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.32 | s42-nomad (formerly nomad1)
244 10.30.50.33 | s43-nomad (formerly nomad2)
245 10.30.50.34 | s44-nomad (formerly nomad3)
246 10.30.50.35 | s45-nomad (formerly nomad4)
247 10.30.50.36 | s17-t33-sut1
248 10.30.50.37 | s18-t33-sut2
249 10.30.50.41 | s3-t21-sut1
250 10.30.50.42 | s4-t21-tg1
251 10.30.50.43 | s11-t31-sut1
252 10.30.50.44 | s12-t31-sut2
253 10.30.50.45 | s13-t31-tg1
254 10.30.50.46 | s19-t33t34-tg1
255 10.30.50.47 | s1-t11-sut1
256 10.30.50.48 | s2-t12-sut1
257 10.30.50.49 | s5-t22-sut1
258 10.30.50.50 | s6-t22-tg1
259 10.30.50.51 | s7-t23-sut1
260 10.30.50.52 | s8-t23-tg1
261 10.30.50.53 | s9-t24-sut1
262 10.30.50.54 | s10-t24-tg1
263 10.30.50.55 | s14-t32-sut1
264 10.30.50.56 | s15-t32-sut2
265 10.30.50.57 | s16-t32-tg1
266 10.30.50.58 | s25-t25-sut1
267 10.30.50.59 | s26-t25-tg1
268 10.30.50.66 | s51-nomad
269 10.30.50.67 | s49-nomad
270 10.30.50.68 | s50-nomad
271 10.30.50.69 | s27-t13-sut
272 10.30.50.255 | Broadcast
277 10.30.55.10 | s28-t26t35-tg1
278 10.30.55.11 | s29-t26-sut1
279 10.30.55.12 | s30-t35-sut1
280 10.30.55.13 | s31-t35-sut2
281 10.30.55.14 | s46-nomad (formerly server-type-c4-1)
282 10.30.55.15 | s47-nomad (formerly server-type-c4-2)
283 10.30.55.16 | s48-nomad (formerly server-type-c4-3)
284 10.30.55.17 | s32-t14-sut1
285 10.30.55.18 | s33-t27-sut1
286 10.30.55.19 | s34-t27-tg1
287 10.30.55.20 | s35-t28-sut1
288 10.30.55.21 | s36-t28-tg1
289 10.30.55.22 | s37-t29-sut1
290 10.30.55.23 | s38-t29-tg1
291 10.30.55.255 | Broadcast
293 ### Management VLAN IP Addresses
296 ------------------------- | -------
299 10.30.51.2 | LF Reserved
300 10.30.51.3 | LF Reserved
301 10.30.51.4 | LF Reserved
302 10.30.51.5 | LF Reserved
303 10.30.51.6 | LF Reserved
304 10.30.51.7 | LF Reserved
305 10.30.51.8 | LF Reserved
306 10.30.51.9 | s22-t35-sut1 (netgate-1)
307 10.30.51.10 | s23-t35-sut2 (netgate-2)
308 10.30.51.11 | s24-t35-sut3 (netgate-3)
309 10.30.51.12 | softiron-1
310 10.30.51.13 | softiron-2
311 10.30.51.14 | softiron-3
312 10.30.51.15 | LF Reserved
314 10.30.51.17 | t1-sut1
315 10.30.51.18 | t1-sut2
317 10.30.51.21 | t2-sut1
318 10.30.51.22 | t2-sut2
320 10.30.51.25 | t3-sut1
321 10.30.51.26 | t3-sut-2
322 10.30.51.28 | s41-nomad
323 10.30.51.29 | s39-nomad
324 10.30.51.30 | s40-nomad
325 10.30.51.32 | s42-nomad (formerly nomad1)
326 10.30.51.33 | s43-nomad (formerly nomad2)
327 10.30.51.34 | s44-nomad (formerly nomad3)
328 10.30.51.35 | s45-nomad (formerly nomad4)
329 10.30.51.36 | s17-t33-sut1
330 10.30.51.37 | s18-t33-sut2
331 10.30.51.41 | s20-t34-sut1
332 10.30.51.42 | s21-t34-sut2
333 10.30.51.44 | s3-t21-sut1
334 10.30.51.45 | s4-t21-tg1
335 10.30.51.46 | s11-t31-sut1
336 10.30.51.47 | s12-t31-sut2
337 10.30.51.48 | s13-t31-tg1
338 10.30.51.49 | s19-t33t34-tg1
339 10.30.51.50 | s1-t11-sut1
340 10.30.51.51 | s2-t12-sut1
341 10.30.51.52 | s5-t22-sut1
342 10.30.51.53 | s6-t22-tg1
343 10.30.51.54 | s7-t23-sut1
344 10.30.51.55 | s8-t23-tg1
345 10.30.51.56 | s9-t24-sut1
346 10.30.51.57 | s10-t24-tg1
347 10.30.51.58 | s14-t32-sut1
348 10.30.51.59 | s15-t32-sut2
349 10.30.51.60 | s16-t32-tg1
350 10.30.51.61 | s25-t25-sut1
351 10.30.51.62 | s26-t25-tg1
352 10.30.51.66 | s51-nomad
353 10.30.51.67 | s49-nomad
354 10.30.51.68 | s50-nomad
355 10.30.51.69 | s27-t13-sut1
356 10.30.51.70-10.30.51.105 | FREE
357 10.30.51.106-10.30.51.180 | FREE
358 10.30.51.181-10.30.51.254 | FREE
359 10.30.51.255 | Broadcast
362 10.32.8.10 | s28-t26t35-tg1
363 10.32.8.11 | s29-t26-sut1
364 10.32.8.12 | s30-t35-sut1
365 10.32.8.13 | s31-t35-sut2
366 10.32.8.14 | s46-nomad (formerly server-type-c4-1)
367 10.32.8.15 | s47-nomad (formerly server-type-c4-2)
368 10.32.8.16 | s48-nomad (formerly server-type-c4-3)
369 10.32.8.17 | s32-t14-sut1
370 10.32.8.18 | s33-t27-sut1
371 10.32.8.19 | s34-t27-tg1
372 10.32.8.20 | s35-t28-sut1
373 10.32.8.21 | s36-t28-tg1
374 10.32.8.22 | s37-t29-sut1
375 10.32.8.23 | s38-t29-tg1
376 10.32.8.255 | Broadcast
378 ## Server Specifications
382 FD.io CSIT lab contains following server types:
384 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
385 - Quantity: 6 servers.
386 - Physical connectivity:
387 - CIMC and host management ports.
388 - NIC ports connected in 3-node topologies.
389 - Main HW configuration:
390 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
391 - Processors: 2* E5-2699v3 2.3 GHz.
392 - RAM Memory: 16* 32GB DDR4-2133MHz.
393 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
394 - NICs configuration:
395 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
396 - PCIe Slot1: Cisco VIC 1385 2p40GE.
397 - PCIe Slot2: Intel NIC x520 2p10GE.
399 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
400 - PCIe Slot4: Intel NIC xl710 2p40GE.
401 - PCIe Slot5: Intel NIC x710 2p10GE.
402 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
403 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
404 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
405 - Quantity: 3 servers.
406 - Physical connectivity:
407 - CIMC and host management ports.
408 - NIC ports connected in 3-node topologies.
409 - Main HW configuration:
410 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
411 - Processors: 2* E5-2699v3 2.3 GHz.
412 - RAM Memory: 16* 32GB DDR4-2133MHz.
413 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
414 - NICs configuration:
415 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
416 - PCIe Slot1: Intel NIC xl710 2p40GE.
417 - PCIe Slot2: Intel NIC x710 2p10GE.
418 - PCIe Slot3: Intel NIC x710 2p10GE.
419 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
420 - PCIe Slot4: Intel NIC xl710 2p40GE.
421 - PCIe Slot5: Intel NIC x710 2p10GE.
422 - PCIe Slot6: Intel NIC x710 2p10GE.
424 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
425 - Quantity: 3 servers.
426 - Physical connectivity:
427 - CIMC and host management ports.
428 - no NIC ports, standalone setup.
429 - Main HW configuration:
430 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
431 - Processors: 2* E5-2699v3 2.3 GHz.
432 - RAM Memory: 16* 32GB DDR4-2133MHz.
433 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
434 - NICs configuration:
435 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
437 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
440 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
442 - Physical connectivity:
443 - IPMI and host management ports.
444 - NIC ports connected into 2-node and 3-node topologies.
445 - Main HW configuration:
446 - Chassis: SuperMicro SYS-7049GP-TRT.
447 - Motherboard: SuperMicro X11DPG-QT.
448 - Processors: 2* Intel Platinum 8180 2.5 GHz.
449 - RAM Memory: 16* 16GB DDR4-2666MHz.
450 - Disks: 2* 1.6TB 6G SATA SSD.
451 - NICs configuration:
452 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
453 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
454 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
455 - PCIe Slot9 5e:00.xx: empty.
456 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
457 - PCIe Slot6 86:00.xx: empty.
458 - PCIe Slot8 af:00.xx: empty.
459 - PCIe Slot10 d8:00.xx: empty.
460 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
462 - Physical connectivity:
463 - IPMI and host management ports.
464 - NIC ports connected into 2-node and 3-node topologies.
465 - Main HW configuration:
466 - Chassis: SuperMicro SYS-7049GP-TRT.
467 - Motherboard: SuperMicro X11DPG-QT.
468 - Processors: 2* Intel Platinum 8180 2.5 GHz.
469 - RAM Memory: 16* 16GB DDR4-2666MHz.
470 - Disks: 2* 1.6TB 6G SATA SSD.
471 - NICs configuration:
472 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
473 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
474 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
475 - PCIe Slot9 5e:00.xx: empty.
476 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
477 - PCIe Slot6 86:00.xx: empty.
478 - PCIe Slot8 af:00.xx: empty.
479 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
480 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
482 - Physical connectivity:
483 - IPMI(?) and host management ports.
484 - NIC ports connected into 3-node topology.
485 - Main HW configuration:
486 - Chassis: Huawei TaiShan 2280.
487 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
488 - RAM Memory: 8* 16GB DDR4-2400MT/s
489 - Disks: 1* 4TB SATA HDD
490 - NICs configuration:
491 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
492 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
493 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
495 - Physical connectivity:
496 - Host management ports.
497 - NIC ports connected into 2-node and 3-node topologies.
498 - Main HW configuration:
499 - Chassis: MACCHIATObin.
500 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
501 - RAM Memory: 1* 16GB DDR4
502 - Disks: 1* 128GB(?) SATA SDD
503 - NICs configuration:
504 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
505 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
506 - Quantity: TBD based on testbed allocation.
507 - Physical connectivity:
508 - Management: serial Port (usb) for console
509 - NIC ports connected into 2-node.
510 - Main HW configuration:
511 - Chassis: Netgate XG-2758-1u
512 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
513 - RAM Memory: 16GB ECC
515 - NICs configuration:
516 - 2x 10Gb Intel 82599ES
518 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
520 - Physical connectivity:
521 - IPMI and host management ports.
522 - NIC ports connected into 2-node and 3-node topologies.
523 - Main HW configuration:
524 - Chassis: SuperMicro SYS-7049GP-TRT.
525 - Motherboard: SuperMicro X11DPG-QT.
526 - Processors: 2* Intel Platinum 8180 2.5 GHz.
527 - RAM Memory: 16* 16GB DDR4-2666MHz.
528 - Disks: 2* 1.6TB 6G SATA SSD.
529 - NICs configuration:
530 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
531 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
532 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
533 - PCIe Slot9 5e:00.xx: empty.
534 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
535 - PCIe Slot6 86:00.xx: empty.
536 - PCIe Slot8 af:00.xx: empty.
537 - PCIe Slot10 d8:00.xx: empty.
538 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
540 - Physical connectivity:
541 - Host management interface: 10/100/1000-BaseT.
542 - 8-port 10GE SFP+ integrated NIC.
543 - Main HW configuration:
544 - Chassis: PS10GE4NG.
545 - Motherboard: SuperMicro X11DPG-QT.
546 - Processors: Quad-Core, Intel Processor.
547 - HW accelerators: FPGA offload.
549 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
550 - Physical Interfaces: 4 * 10GE SFP+.
551 - Operating System: Native IxOS.
552 - Interface configuration:
557 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
559 - Physical connectivity:
560 - IPMI and host management ports.
562 - Main HW configuration:
563 - Chassis: SuperMicro SYS-7049GP-TRT.
564 - Motherboard: SuperMicro X11DPG-QT.
565 - Processors: 2* Intel Platinum 8180 2.5 GHz.
566 - RAM Memory: 16* 16GB DDR4-2666MHz.
567 - Disks: 2* 1.6TB 6G SATA SSD.
568 - NICs configuration:
569 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
570 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
571 - PCIe Slot4 3b:00.xx: empty.
572 - PCIe Slot9 5e:00.xx: empty.
573 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
574 - PCIe Slot6 86:00.xx: empty.
575 - PCIe Slot8 af:00.xx: empty.
576 - PCIe Slot10 d8:00.xx: empty.
577 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
579 - Physical connectivity:
580 - IPMI and host management ports.
581 - NIC ports connected into 1-node topologies.
582 - Main HW configuration:
583 - Chassis: Gigabyte R181-T90 1U
584 - Motheboard: MT91-FS1
585 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
586 - RAM Memory: 4* 32GB RDIMM
587 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
588 - NICs configuration:
590 - PCIe Slot1 05:00.xx: XL710-QDA2.
591 - PCIe Slot3 08:00.xx: XL710-QDA2.
593 - PCIe Slot6 85:00.xx: XL710-QDA2.
594 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
596 - Physical connectivity:
597 - IPMI and host management ports.
599 - Main HW configuration:
600 - Chassis: SuperMicro SYS-E300-9A
601 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
602 - RAM Memory: 32GB ECC
604 - NICs configuration:
605 - 2x 10Gb Intel x553 fiber ports
606 - 2x 10Gb Intel x553 copper ports
607 - 4x 1GB Intel I350 ports
609 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
611 - Physical connectivity:
612 - IPMI and host management ports.
613 - NIC ports connected into 1-node testbed topologies.
614 - Main HW configuration:
615 - Chassis: SuperMicro SYS-7049GP-TRT.
616 - Motherboard: SuperMicro X11DPG-QT.
617 - Processors: 2* Intel Platinum 8280 2.7 GHz.
618 - RAM Memory: 12* 16GB DDR4-2933.
619 - Disks: 2* 1.92TB SATA SSD.
620 - NICs configuration:
621 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
622 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
623 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
624 - PCIe Slot9 5e:00.xx: empty.
625 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
626 - PCIe Slot6 86:00.xx: empty.
627 - PCIe Slot8 af:00.xx: empty.
628 - PCIe Slot10 d8:00.xx: empty.
630 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
632 - Physical connectivity:
633 - IPMI and host management ports.
634 - NIC ports connected into 2-node testbed topologies.
635 - Main HW configuration:
636 - Chassis: SuperMicro SYS-7049GP-TRT.
637 - Motherboard: SuperMicro X11DPG-QT.
638 - Processors: 2* Intel Gold 6252N 2.3 GHz.
639 - RAM Memory: 12* 16GB DDR4-2933.
640 - Disks: 2* 1.92TB SATA SSD.
641 - NICs configuration:
642 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
643 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
644 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
645 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
646 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
647 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
648 - PCIe Slot6 86:00.xx: empty.
649 - PCIe Slot8 af:00.xx: empty.
650 - PCIe Slot10 d8:00.xx: empty.
651 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
653 - Physical connectivity:
654 - IPMI and host management ports.
655 - NIC ports connected into 2-node testbed topologies.
656 - Main HW configuration:
657 - Chassis: SuperMicro SYS-7049GP-TRT.
658 - Motherboard: SuperMicro X11DPG-QT.
659 - Processors: 2* Intel Platinum 8280 2.7 GHz.
660 - RAM Memory: 12* 16GB DDR4-2933.
661 - Disks: 2* 1.92TB SATA SSD.
662 - NICs configuration:
663 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
664 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
665 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
666 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
667 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
668 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
669 - PCIe Slot6 86:00.xx: empty.
670 - PCIe Slot8 af:00.xx: empty.
671 - PCIe Slot10 d8:00.xx: empty.
673 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
675 - Physical connectivity:
676 - CIMC and host management ports.
677 - no NIC ports, standalone setup.
678 - Main HW configuration:
679 - Chassis: SuperMicro 1029P-WTRT.
680 - Motherboard: SuperMicro X11DDW-NT.
681 - Processors: 2* Intel Platinum 8280 2.7 GHz.
682 - RAM Memory: 12* 16GB DDR4-2933.
683 - Disks: 4* 1.92TB SATA SSD.
684 - NICs configuration:
691 ### Naming Convention
693 Following naming convention is used within this page to specify physical
694 connectivity and wiring across defined CSIT testbeds:
697 - testbedname: testbedN.
699 - traffic-generator: tN-tgW.
700 - system-under-testX: tN-sutX.
705 - N - testbed number.
706 - tgW - server acts as traffic-generator with W index.
707 - sutX - server acts as system-under-test with X index.
708 - Y - PCIe slot number denoting a NIC card number within the host.
709 - Z - port number on the NIC card.
712 ## Testbeds Configuration
714 ### Per Testbed Server Allocation and Naming
716 #### 1-Node-Skylake Servers (1n-skx) PROD
719 - SUT [Server-Type-B6]:
720 - testbedname: testbed11.
721 - hostname: s1-t11-sut1.
722 - IPMI IP: 10.30.50.47
723 - Host IP: 10.30.51.50
725 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
726 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
727 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
728 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
729 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
730 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
731 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
732 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
733 - SUT [Server-Type-B6]:
734 - testbedname: testbed12.
735 - hostname: s2-t12-sut1.
736 - IPMI IP: 10.30.50.48
737 - Host IP: 10.30.51.51
739 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
740 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
741 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
742 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
743 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
744 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
745 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
746 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
749 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
752 - SUT [Server-Type-B9]:
753 - testbedname: testbed13.
754 - hostname: s27-t13-sut1.
755 - IPMI IP: 10.30.50.69
756 - Host IP: 10.30.51.69
758 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
759 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
760 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
761 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
762 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
763 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
766 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
769 - SUT [Server-Type-C1]:
770 - testbedname: testbed11.
771 - hostname: s32-t14-sut1.
772 - IPMI IP: 10.30.55.17
773 - Host IP: 10.32.8.17
775 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
776 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
777 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
778 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
779 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
780 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
781 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
782 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
785 #### 2-Node-Skylake Servers (2n-skx) PROD
788 - SUT [Server-Type-B1]:
789 - testbedname: testbed21.
790 - hostname: s3-t21-sut1.
791 - IPMI IP: 10.30.50.41
792 - Host IP: 10.30.51.44
794 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
795 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
796 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
797 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
798 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
799 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
800 - TG [Server-Type-B2]:
801 - testbedname: testbed21.
802 - hostname: s4-t21-tg1.
803 - IPMI IP: 10.30.50.42
804 - Host IP: 10.30.51.45
806 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
807 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
808 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
809 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
810 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
811 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
812 - SUT [Server-Type-B1]:
813 - testbedname: testbed22.
814 - hostname: s5-t22-sut1.
815 - IPMI IP: 10.30.50.49
816 - Host IP: 10.30.51.52
818 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
819 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
820 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
821 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
822 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
823 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
824 - TG [Server-Type-B2]:
825 - testbedname: testbed22.
826 - hostname: s6-t22-tg1.
827 - IPMI IP: 10.30.50.50
828 - Host IP: 10.30.51.53
830 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
831 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
832 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
833 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
834 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
835 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
836 - SUT [Server-Type-B1]:
837 - testbedname: testbed23.
838 - hostname: s7-t23-sut1.
839 - IPMI IP: 10.30.50.51
840 - Host IP: 10.30.51.54
842 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
843 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
844 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
845 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
846 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
847 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
848 - TG [Server-Type-B2]:
849 - testbedname: testbed23.
850 - hostname: s8-t23-tg1.
851 - IPMI IP: 10.30.50.52
852 - Host IP: 10.30.51.55
854 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
855 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
856 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
857 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
858 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
859 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
860 - SUT [Server-Type-B1]:
861 - testbedname: testbed24.
862 - hostname: s9-t24-sut1.
863 - IPMI IP: 10.30.50.53
864 - Host IP: 10.30.51.56
866 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
867 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
868 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
869 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
870 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872 - TG [Server-Type-B2]:
873 - testbedname: testbed24.
874 - hostname: s10-t24-tg1.
875 - IPMI IP: 10.30.50.54
876 - Host IP: 10.30.51.57
878 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
879 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
880 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
881 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
882 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
883 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
886 #### 2-Node-Denverton Servers (2n-dnv) WIP
888 Note: ServerB28 (TG) is shared between testbed26 & testbed35
891 - TG [Server-Type-B2]:
892 - testbednames: testbed26 and testbed35.
893 - hostname: s28-t26t35-tg1.
894 - IPMI IP: 10.30.55.10
895 - Host IP: 10.32.8.10
897 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
898 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
899 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
900 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
901 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
902 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
903 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
904 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
905 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
906 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
907 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
908 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
909 - SUT [Server-Type-B10]:
910 - testbednames: testbed26.
911 - hostname: s29-t26-sut1.
912 - IPMI IP: 10.30.55.11
913 - Host IP: 10.32.8.11
915 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
916 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
917 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
918 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
921 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
924 - SUT [Server-Type-B8]:
925 - testbedname: testbed25.
926 - hostname: s25-t25-sut1.
927 - IPMI IP: 10.30.50.58
928 - Host IP: 10.30.51.61
930 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
931 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
932 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
933 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
934 - TG [Server-Type-B7]:
935 - testbedname: testbed25.
936 - hostname: s26-t25-tg1.
937 - IPMI IP: 10.30.50.59
938 - Host IP: 10.30.51.62
940 - s26-t25-tg1-p1 - 10GE-port1.
941 - s26-t25-tg1-p2 - 10GE-port2.
942 - s26-t25-tg1-p3 - 10GE-port3.
943 - s26-t25-tg1-p4 - 10GE-port4.
946 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
949 - SUT [Server-Type-C2]:
950 - testbedname: testbed27.
951 - hostname: s33-t27-sut1.
952 - IPMI IP: 10.30.55.18
953 - Host IP: 10.32.8.18
955 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
956 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
957 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
958 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
959 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
960 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
961 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
962 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
963 - TG [Server-Type-C3]:
964 - testbedname: testbed27.
965 - hostname: s34-t27-tg1.
966 - IPMI IP: 10.30.55.19
967 - Host IP: 10.32.8.19
969 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
970 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
971 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
972 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
973 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
974 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
975 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
976 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
977 - SUT [Server-Type-C2]:
978 - testbedname: testbed28.
979 - hostname: s35-t28-sut1.
980 - IPMI IP: 10.30.55.20
981 - Host IP: 10.32.8.20
983 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
984 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
985 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
986 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
987 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
988 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
989 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
990 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
991 - TG [Server-Type-C3]:
992 - testbedname: testbed28.
993 - hostname: s36-t28-tg1.
994 - IPMI IP: 10.30.55.21
995 - Host IP: 10.32.8.21
997 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
998 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
999 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1000 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1001 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1002 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1003 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1004 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1005 - SUT [Server-Type-C2]:
1006 - testbedname: testbed29.
1007 - hostname: s37-t29-sut1.
1008 - IPMI IP: 10.30.55.22
1009 - Host IP: 10.32.8.22
1011 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1012 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1013 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1014 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1015 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1016 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1017 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1018 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1019 - TG [Server-Type-C3]:
1020 - testbedname: testbed29.
1021 - hostname: s38-t29-tg1.
1022 - IPMI IP: 10.30.55.23
1023 - Host IP: 10.32.8.23
1025 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1026 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1027 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1028 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1029 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1030 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1031 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1032 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1035 #### 3-Node-Haswell Servers (3n-hsw) PROD
1038 1. SUT [Server-Type-A1]:
1039 - testbedname: testbed1.
1040 - hostname: t1-sut1.
1041 - CIMC IP: 10.30.50.17
1042 - Host IP: 10.30.51.17
1044 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1045 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1046 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1047 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1048 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1049 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1050 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1051 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1052 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1053 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1054 2. SUT [Server-Type-A1]:
1055 - testbedname: testbed1.
1056 - hostname: t1-sut2.
1057 - CIMC IP: 10.30.50.18
1058 - Host IP: 10.30.51.18
1060 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1061 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1062 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1063 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1064 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1065 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1066 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1067 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1068 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1069 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1070 3. TG [Server-Type-A2]:
1071 - testbedname: testbed1.
1073 - CIMC IP: 10.30.50.16
1074 - Host IP: 10.30.51.16
1076 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1077 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1078 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1079 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1080 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1081 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1082 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1083 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1084 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1085 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1086 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1087 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1088 4. SUT [Server-Type-A1]:
1089 - testbedname: testbed2.
1090 - hostname: t2-sut1.
1091 - CIMC IP: 10.30.50.21
1092 - Host IP: 10.30.51.21
1094 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1095 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1096 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1097 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1098 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1099 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1100 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1101 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1102 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1103 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1104 5. SUT [Server-Type-A1]:
1105 - testbedname: testbed2.
1106 - hostname: t2-sut2.
1107 - CIMC IP: 10.30.50.22
1108 - Host IP: 10.30.51.22
1110 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1111 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1112 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1113 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1114 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1115 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1116 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1117 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1118 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1119 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1120 6. TG [Server-Type-A2]:
1121 - testbedname: testbed2.
1123 - CIMC IP: 10.30.50.20
1124 - Host IP: 10.30.51.20
1126 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1127 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1128 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1129 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1130 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1131 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1132 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1133 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1134 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1135 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1136 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1137 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1138 7. SUT [Server-Type-A1]:
1139 - testbedname: testbed3.
1140 - hostname: t3-sut1.
1141 - CIMC IP: 10.30.50.25
1142 - Host IP: 10.30.51.25
1144 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1145 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1146 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1147 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1148 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1149 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1150 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1151 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1152 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1153 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1154 8. SUT [Server-Type-A1]:
1155 - testbedname: testbed3.
1156 - hostname: t3-sut2.
1157 - CIMC IP: 10.30.50.26
1158 - Host IP: 10.30.51.26
1160 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1161 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1162 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1163 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1164 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1165 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1166 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1167 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1168 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1169 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1170 9. TG [Server-Type-A2]:
1171 - testbedname: testbed3.
1173 - CIMC IP: 10.30.50.24
1174 - Host IP: 10.30.51.24
1176 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1177 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1178 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1179 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1180 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1181 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1182 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1183 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1184 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1185 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1186 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1187 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1190 #### 3-Node-Skylake Servers (3n-skx) PROD
1193 - ServerB11 [Server-Type-B1]:
1194 - testbedname: testbed31.
1195 - hostname: s11-t31-sut1.
1196 - IPMI IP: 10.30.50.43
1197 - Host IP: 10.30.51.46
1199 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1200 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1201 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1202 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1203 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1204 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1205 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1206 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1207 - ServerB12 [Server-Type-B1]:
1208 - testbedname: testbed31.
1209 - hostname: s12-t31-sut2.
1210 - IPMI IP: 10.30.50.44
1211 - Host IP: 10.30.51.47
1213 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1214 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1215 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1216 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1217 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1220 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1221 - ServerB13 [Server-Type-B2]:
1222 - testbedname: testbed31.
1223 - hostname: s13-t31-tg1.
1224 - IPMI IP: 10.30.50.45
1225 - Host IP: 10.30.51.48
1227 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1228 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1229 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1230 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1231 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1232 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1233 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1234 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1235 - ServerB14 [Server-Type-B1]:
1236 - testbedname: testbed32.
1237 - hostname: s14-t32-sut1.
1238 - IPMI IP: 10.30.50.55
1239 - Host IP: 10.30.51.58
1241 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1242 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1243 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1244 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1245 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1246 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1247 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1248 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1249 - ServerB15 [Server-Type-B1]:
1250 - testbedname: testbed32.
1251 - hostname: s15-t32-sut2.
1252 - IPMI IP: 10.30.50.56
1253 - Host IP: 10.30.51.59
1255 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1256 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1257 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1258 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1259 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1260 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1261 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1262 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1263 - ServerB16 [Server-Type-B2]:
1264 - testbedname: testbed32.
1265 - hostname: s16-t32-tg1.
1266 - IPMI IP: 10.30.50.57
1267 - Host IP: 10.30.51.60
1269 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1270 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1271 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1272 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1273 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1274 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1275 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1276 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1279 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1281 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1284 - ServerB22 [Server-Type-B5]:
1285 - testbedname: testbed35.
1286 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1287 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1288 - Host IP: 10.30.51.9
1290 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1291 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1293 - ServerB23 [Server-Type-B5]:
1294 - testbedname: testbed35.
1295 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1296 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1297 - Host IP: 10.30.51.10
1299 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1300 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1302 - ServerB24 [Server-Type-B5]:
1303 - testbedname: testbed35.
1304 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1305 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1306 - Host IP: 10.30.51.11
1308 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1309 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1313 #### 3-Node-Taishan Servers (3n-tsh) WIP
1315 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1318 - ServerB17 [Server-Type-B3]:
1319 - testbedname: testbed33.
1320 - hostname: s17-t33-sut1.
1321 - IPMI IP: 10.30.50.36
1322 - Host IP: 10.30.51.36
1324 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1325 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1326 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1327 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1328 - ServerB18 [Server-Type-B3]:
1329 - testbedname: testbed33.
1330 - hostname: s18-t33-sut2.
1331 - IPMI IP: 10.30.50.37
1332 - Host IP: 10.30.51.37
1334 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1335 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1336 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1337 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1338 - ServerB19 [Server-Type-B2]:
1339 - testbednames: testbed33 and testbed34.
1340 - hostname: s19-t33t34-tg1.
1341 - IPMI IP: 10.30.50.46
1342 - Host IP: 10.30.51.49
1344 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1345 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1346 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1347 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1348 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1349 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1350 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1351 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1352 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1353 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1354 - ServerB20 [Server-Type-B4]:
1355 - testbedname: testbed34.
1356 - hostname: s20-t34-sut1.
1358 - Host IP: 10.30.51.41
1360 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1361 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1362 - ServerB21 [Server-Type-B4]:
1363 - testbedname: testbed34.
1364 - hostname: s21-t34-sut2.
1366 - Host IP: 10.30.51.42
1368 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1369 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1372 #### 3-Node-Denverton Servers (3n-dnv) WIP
1375 - ServerB30 [Server-Type-B10]:
1376 - testbednames: testbed35.
1377 - hostname: s30-t35-sut1.
1378 - IPMI IP: 10.30.55.12
1379 - Host IP: 10.32.8.12
1381 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1382 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1383 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1384 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1385 - ServerB31 [Server-Type-B10]:
1386 - testbednames: testbed35.
1387 - hostname: s31-t35-sut2.
1388 - IPMI IP: 10.30.55.13
1389 - Host IP: 10.32.8.13
1391 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1392 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1393 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1394 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1397 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1403 ### Per Testbed Wiring
1405 #### 1-Node-Skylake Wiring (1n-skx) PROD
1409 - ring1 10GE-ports x710-4p10GE:
1410 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1411 - ring2 10GE-ports x710-4p10GE:
1412 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1413 - ring3 10GE-ports x710-4p10GE:
1414 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1415 - ring4 10GE-ports x710-4p10GE:
1416 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1418 - ring1 10GE-ports x710-4p10GE:
1419 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1420 - ring2 10GE-ports x710-4p10GE:
1421 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1422 - ring3 10GE-ports x710-4p10GE:
1423 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1424 - ring4 10GE-ports x710-4p10GE:
1425 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1428 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1432 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1433 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1434 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1435 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1436 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1437 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1440 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1444 - ring1 10GE-ports x710-4p10GE:
1445 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1446 - ring2 10GE-ports x710-4p10GE:
1447 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1448 - ring3 10GE-ports x710-4p10GE:
1449 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1450 - ring4 10GE-ports x710-4p10GE:
1451 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1454 #### 2-Node-Skylake Wiring (2n-skx) PROD
1458 - ring1 10GE-ports x710-4p10GE on SUT:
1459 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1460 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1461 - ring2 10GE-ports x710-4p10GE on SUT:
1462 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1463 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1464 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1465 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1466 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1468 - ring1 10GE-ports x710-4p10GE on SUT:
1469 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1470 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1471 - ring2 10GE-ports x710-4p10GE on SUT:
1472 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1473 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1474 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1475 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1476 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1478 - ring1 10GE-ports x710-4p10GE on SUT:
1479 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1480 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1481 - ring2 10GE-ports x710-4p10GE on SUT:
1482 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1483 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1484 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1485 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1486 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1488 - ring1 10GE-ports x710-4p10GE on SUT:
1489 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1490 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1491 - ring2 10GE-ports x710-4p10GE on SUT:
1492 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1493 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1494 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1495 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1496 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1499 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1503 - ring1 10GE-ports x553 copper port on SUT:
1504 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1505 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1506 - ring2 10GE-ports x553 fiber port on SUT:
1507 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1508 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1511 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1515 - link1 10GE-port x710-4p10GE on SUT:
1516 - t25-tg1-p1 to t25-sut1-c2/p1.
1517 - link2 10GE-port x710-4p10GE on SUT:
1518 - t25-tg1-p2 to t25-sut1-c2/p2.
1519 - link3 10GE-port x710-4p10GE on SUT:
1520 - t25-tg1-p3 to t25-sut1-c2/p3.
1521 - link4 10GE-port x710-4p10GE on SUT:
1522 - t25-tg1-p4 to t25-sut1-c2/p4.
1525 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1529 - ring1 10GE-ports x710-4p10GE on SUT:
1530 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1531 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1532 - ring2 10GE-ports x710-4p10GE on SUT:
1533 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1534 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1535 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1536 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1537 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1538 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1539 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1540 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1542 - ring1 10GE-ports x710-4p10GE on SUT:
1543 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1544 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1545 - ring2 10GE-ports x710-4p10GE on SUT:
1546 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1547 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1548 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1549 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1550 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1551 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1552 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1553 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1555 - ring1 10GE-ports x710-4p10GE on SUT:
1556 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1557 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1558 - ring2 10GE-ports x710-4p10GE on SUT:
1559 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1560 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1561 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1562 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1563 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1564 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1565 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1566 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1569 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1573 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1574 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1575 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1576 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1577 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1578 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1579 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1580 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1581 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1582 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1583 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1584 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1585 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1586 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1587 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1588 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1589 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1590 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1591 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1592 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1593 - TG loopback ports Intel NIC x710 2p10GE
1594 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1597 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1598 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1599 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1600 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1601 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1602 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1603 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1604 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1605 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1606 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1607 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1608 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1609 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1610 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1611 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1612 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1613 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1614 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1615 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1616 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1617 - TG loopback ports Intel NIC x710 2p10GE
1618 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1621 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1622 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1623 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1624 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1625 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1626 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1627 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1628 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1629 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1630 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1631 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1632 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1633 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1634 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1635 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1636 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1637 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1638 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1639 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1640 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1641 - TG loopback ports Intel NIC x710 2p10GE
1642 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1645 #### 3-Node-Skylake Wiring (3n-skx) PROD
1649 - ring1 10GE-ports x710-4p10GE on SUTs:
1650 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1651 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1652 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1653 - ring2 10GE-ports x710-4p10GE on SUT:
1654 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1655 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1656 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1657 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1658 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1659 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1660 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1661 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1662 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1663 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1664 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1665 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1666 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1667 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1669 - ring1 10GE-ports x710-4p10GE on SUTs:
1670 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1671 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1672 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1673 - ring2 10GE-ports x710-4p10GE on SUT:
1674 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1675 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1676 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1677 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1678 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1679 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1680 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1681 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1682 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1683 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1684 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1685 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1686 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1687 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1690 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1696 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1700 - ring1 10GE-ports x520-2p10GE on SUTs:
1701 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1702 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1703 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1704 - ring2 25GE-ports cx4-2p25GE on SUTs:
1705 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1706 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1707 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1710 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1714 - ring1 10GE-ports Marvell on SUTs:
1715 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1716 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1717 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1720 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1724 - ring1 10GE-ports x553 copper port on SUTs:
1725 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1726 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1727 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1728 - ring2 10GE-ports x553 fiber port on SUTs:
1729 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1730 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1731 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1739 1. Ixia PerfectStorm One Appliance
1741 - Chassis: PS10GE4NG.
1742 - Motherboard: SuperMicro X11DPG-QT.
1743 - Processors: Quad-Core, Intel Processor.
1744 - HW accelerators: FPGA offload.
1746 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1747 - Physical Interfaces: 4 * 10GE SFP+.
1748 - Operating System: Native IxOS.
1754 1. Arm Cortex A-72 servers
1756 - Chassis: Marvell ThunderX2
1757 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1758 - RAM Memory: 4* 32GB RDIMM
1759 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1760 - 2 * Huawei TaiShan 2280.
1761 - Chassis: Huawei TaiShan 2280.
1762 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1763 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1764 - Disks: 1* 4TB SATA HDD.
1766 - Chassis: MACCHIATObin.
1767 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1768 - RAM Memory: 1* 16GB DDR4.
1769 - Disks: 1* 128GB(?) SATA SDD.
1772 ### Xeon and Atom Servers
1775 1. Intel Xeon servers:
1776 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1777 - Chassis: SuperMicro SYS-7049GP-TRT.
1778 - Motherboard: SuperMicro X11DPG-QT.
1779 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1780 - RAM Memory: 16* 16GB DDR4-2666MHz.
1781 - Disks: 2* 1.6TB 6G SATA SSD.
1782 2. Intel Atom servers with Rangely processors.
1783 - 3 * Netgate XG-2758-1u
1784 - Chassis: Netgate XG-2758-1u
1785 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1786 - RAM Memory: 16GB ECC
1790 ### Network Interface Cards
1794 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1795 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1796 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1798 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1800 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1802 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1805 ### Pluggables and Cables
1811 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1812 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1818 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1829 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable