1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
15 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
18 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
34 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
36 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
37 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
38 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
39 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
41 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
45 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
46 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
48 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
51 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
52 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
53 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
54 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
55 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb #clx #zn2
75 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0 0
76 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0
77 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0 0 0
78 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0
79 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0
80 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0
81 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0
82 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0
83 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0 0
84 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0
85 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0
86 12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 0 0
87 13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 0 0
88 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0
89 15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2
90 Totals: 22 35 18 12 19 1 2 3 1 2 2 7 2
93 ### 1-Node-Skylake Xeon Intel (1n-skx)
95 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
96 ports connected back-to-back ([Server Types](#server-types)).
97 Used for FD.io VPP_Device functional driver tests.
99 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
101 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
102 ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
105 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
107 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
108 NIC ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
112 ### 2-Node-Skylake Xeon Intel (2n-skx)
114 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
115 (Server-Type-B2) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
147 ### 3-Node-Haswell Xeon Intel (3n-hsw)
149 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
150 TG (Server-Type-A2) connected in a 3-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
154 ### 3-Node-Skylake Xeon Intel (3n-skx)
156 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
157 TG (Server-Type-B2) connected in a 3-node circular topology.
158 Used for FD.io performance tests.
160 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
162 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
163 TG (Server-Type-B2) connected in a 3-node circular topology
164 ([Server Types](#server-types)).
165 Used for FD.io performance tests.
167 ### 3-Node-MACCHIATObin Arm Marvell
169 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
170 one TG (Server-Type-B2) connected in a 3-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
174 ### 3-Node-Rangeley Atom Testbeds
176 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
177 TG (Server-Type-2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
185 For management purposes, each server must have following two ports
186 connected to the management network:
190 - IPMI - Intelligent Platform Management Interface.
191 - Required for access to embedded server management with WebUI, CLI,
192 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
193 - 1GE/10GE/40GE management port
194 - hostOS management port for general system management.
199 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
200 Management port, which are connected to two different VLANs.
204 - Subnet: 10.30.50.0/24
205 - Gateway: 10.30.50.1
206 - Broadcast: 10.30.50.255
207 - DNS1: 199.204.44.24
208 - DNS2: 199.204.47.54
210 - Subnet: 10.30.51.0/24
211 - Gateway: 10.30.51.1
212 - Broadcast: 10.30.51.255
213 - DNS1: 199.204.44.24
214 - DNS2: 199.204.47.54
217 To access these hosts, VPN connection is required.
219 ### LOM (IPMI) VLAN IP Addresses
222 ------------ | -------
225 10.30.50.2 | LF Reserved
226 10.30.50.3 | LF Reserved
227 10.30.50.4 | LF Reserved
228 10.30.50.5 | LF Reserved
229 10.30.50.6 | LF Reserved
230 10.30.50.7 | LF Reserved
231 10.30.50.8 | LF Reserved
232 10.30.50.9 | LF Reserved
233 10.30.50.10 | LF Reserved
234 10.30.50.11 | LF Reserved
235 10.30.50.12 | LF Reserved
236 10.30.50.13 | LF Reserved
237 10.30.50.14 | LF Reserved
238 10.30.50.15 | LF Reserved
240 10.30.50.17 | t1-sut1
241 10.30.50.18 | t1-sut2
243 10.30.50.21 | t2-sut1
244 10.30.50.22 | t2-sut2
246 10.30.50.25 | t3-sut1
247 10.30.50.26 | t3-sut-2
248 10.30.50.28 | s41-nomad
249 10.30.50.29 | s39-nomad
250 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
251 10.30.50.30 | s40-nomad
252 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
253 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
254 10.30.50.32 | s42-nomad (formerly nomad1)
255 10.30.50.33 | s43-nomad (formerly nomad2)
256 10.30.50.34 | s44-nomad (formerly nomad3)
257 10.30.50.35 | s45-nomad (formerly nomad4)
258 10.30.50.36 | s17-t33-sut1
259 10.30.50.37 | s18-t33-sut2
260 10.30.50.38 | fdio-marvell-dev
261 10.30.50.39 | s53-nomad
262 10.30.50.40 | s54-nomad
263 10.30.50.41 | s3-t21-sut1
264 10.30.50.42 | s4-t21-tg1
265 10.30.50.43 | s11-t31-sut1
266 10.30.50.44 | s12-t31-sut2
267 10.30.50.45 | s13-t31-tg1
268 10.30.50.46 | s19-t33t34-tg1
269 10.30.50.47 | s1-t11-sut1
270 10.30.50.48 | s2-t12-sut1
271 10.30.50.49 | s5-t22-sut1
272 10.30.50.50 | s6-t22-tg1
273 10.30.50.51 | s7-t23-sut1
274 10.30.50.52 | s8-t23-tg1
275 10.30.50.53 | s9-t24-sut1
276 10.30.50.54 | s10-t24-tg1
277 10.30.50.55 | s14-t32-sut1
278 10.30.50.56 | s15-t32-sut2
279 10.30.50.57 | s16-t32-tg1
280 10.30.50.58 | s25-t25-sut1
281 10.30.50.59 | s26-t25-tg1
282 10.30.50.65 | s52-nomad
283 10.30.50.66 | s51-nomad (out of order)
284 10.30.50.67 | s49-nomad
285 10.30.50.68 | s50-nomad (out of order)
286 10.30.50.69 | s27-t13-sut
287 10.30.50.255 | Broadcast
292 10.30.55.10 | s28-t26t35-tg1
293 10.30.55.11 | s29-t26-sut1
294 10.30.55.12 | s30-t35-sut1
295 10.30.55.13 | s31-t35-sut2
296 10.30.55.14 | s46-nomad (formerly server-type-c4-1)
297 10.30.55.15 | s47-nomad (formerly server-type-c4-2)
298 10.30.55.16 | s48-nomad (formerly server-type-c4-3)
299 10.30.55.17 | s32-t14-sut1
300 10.30.55.18 | s33-t27-sut1
301 10.30.55.19 | s34-t27-tg1
302 10.30.55.20 | s35-t28-sut1
303 10.30.55.21 | s36-t28-tg1
304 10.30.55.22 | s37-t29-sut1
305 10.30.55.23 | s38-t29-tg1
306 10.30.55.24 | s60-t210-sut1
307 10.30.55.25 | s61-t210-tg1
308 10.30.55.255 | Broadcast
310 ### Management VLAN IP Addresses
313 ------------------------- | -------
316 10.30.51.2 | LF Reserved
317 10.30.51.3 | LF Reserved
318 10.30.51.4 | LF Reserved
319 10.30.51.5 | LF Reserved
320 10.30.51.6 | LF Reserved
321 10.30.51.7 | LF Reserved
322 10.30.51.8 | LF Reserved
323 10.30.51.9 | s22-t35-sut1 (netgate-1)
324 10.30.51.10 | s23-t35-sut2 (netgate-2)
325 10.30.51.11 | s24-t35-sut3 (netgate-3)
326 10.30.51.12 | softiron-1
327 10.30.51.13 | softiron-2
328 10.30.51.14 | softiron-3
329 10.30.51.15 | LF Reserved
331 10.30.51.17 | t1-sut1
332 10.30.51.18 | t1-sut2
334 10.30.51.21 | t2-sut1
335 10.30.51.22 | t2-sut2
337 10.30.51.25 | t3-sut1
338 10.30.51.26 | t3-sut-2
339 10.30.51.28 | s41-nomad
340 10.30.51.29 | s39-nomad
341 10.30.51.30 | s40-nomad
342 10.30.51.32 | s42-nomad (formerly nomad1)
343 10.30.51.33 | s43-nomad (formerly nomad2)
344 10.30.51.34 | s44-nomad (formerly nomad3)
345 10.30.51.35 | s45-nomad (formerly nomad4)
346 10.30.51.36 | s17-t33-sut1
347 10.30.51.37 | s18-t33-sut2
348 10.30.51.38 | fdio-marvell-dev
349 10.30.51.39 | s53-nomad
350 10.30.51.40 | s54-nomad
351 10.30.51.41 | s20-t34-sut1
352 10.30.51.42 | s21-t34-sut2
353 10.30.51.44 | s3-t21-sut1
354 10.30.51.45 | s4-t21-tg1
355 10.30.51.46 | s11-t31-sut1
356 10.30.51.47 | s12-t31-sut2
357 10.30.51.48 | s13-t31-tg1
358 10.30.51.49 | s19-t33t34-tg1
359 10.30.51.50 | s1-t11-sut1
360 10.30.51.51 | s2-t12-sut1
361 10.30.51.52 | s5-t22-sut1
362 10.30.51.53 | s6-t22-tg1
363 10.30.51.54 | s7-t23-sut1
364 10.30.51.55 | s8-t23-tg1
365 10.30.51.56 | s9-t24-sut1
366 10.30.51.57 | s10-t24-tg1
367 10.30.51.58 | s14-t32-sut1
368 10.30.51.59 | s15-t32-sut2
369 10.30.51.60 | s16-t32-tg1
370 10.30.51.61 | s25-t25-sut1
371 10.30.51.62 | s26-t25-tg1
372 10.30.51.65 | s52-nomad
373 10.30.51.66 | s51-nomad
374 10.30.51.67 | s49-nomad
375 10.30.51.68 | s50-nomad
376 10.30.51.69 | s27-t13-sut1
377 10.30.51.70-10.30.51.105 | FREE
378 10.30.51.106-10.30.51.180 | FREE
379 10.30.51.181-10.30.51.254 | FREE
380 10.30.51.255 | Broadcast
383 10.32.8.10 | s28-t26t35-tg1
384 10.32.8.11 | s29-t26-sut1
385 10.32.8.12 | s30-t35-sut1
386 10.32.8.13 | s31-t35-sut2
387 10.32.8.14 | s46-nomad (formerly server-type-c4-1)
388 10.32.8.15 | s47-nomad (formerly server-type-c4-2)
389 10.32.8.16 | s48-nomad (formerly server-type-c4-3)
390 10.32.8.17 | s32-t14-sut1
391 10.32.8.18 | s33-t27-sut1
392 10.32.8.19 | s34-t27-tg1
393 10.32.8.20 | s35-t28-sut1
394 10.32.8.21 | s36-t28-tg1
395 10.32.8.22 | s37-t29-sut1
396 10.32.8.23 | s38-t29-tg1
397 10.32.8.24 | s60-t210-sut1
398 10.32.8.25 | s61-t210-tg1
399 10.32.8.255 | Broadcast
401 ## Server Specifications
405 FD.io CSIT lab contains following server types:
407 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
408 - Quantity: 6 servers.
409 - Physical connectivity:
410 - CIMC and host management ports.
411 - NIC ports connected in 3-node topologies.
412 - Main HW configuration:
413 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
414 - Processors: 2* E5-2699v3 2.3 GHz.
415 - RAM Memory: 16* 32GB DDR4-2133MHz.
416 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
417 - NICs configuration:
418 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
419 - PCIe Slot1: Cisco VIC 1385 2p40GE.
420 - PCIe Slot2: Intel NIC x520 2p10GE.
422 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
423 - PCIe Slot4: Intel NIC xl710 2p40GE.
424 - PCIe Slot5: Intel NIC x710 2p10GE.
425 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
426 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
427 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
428 - Quantity: 3 servers.
429 - Physical connectivity:
430 - CIMC and host management ports.
431 - NIC ports connected in 3-node topologies.
432 - Main HW configuration:
433 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
434 - Processors: 2* E5-2699v3 2.3 GHz.
435 - RAM Memory: 16* 32GB DDR4-2133MHz.
436 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
437 - NICs configuration:
438 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
439 - PCIe Slot1: Intel NIC xl710 2p40GE.
440 - PCIe Slot2: Intel NIC x710 2p10GE.
441 - PCIe Slot3: Intel NIC x710 2p10GE.
442 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
443 - PCIe Slot4: Intel NIC xl710 2p40GE.
444 - PCIe Slot5: Intel NIC x710 2p10GE.
445 - PCIe Slot6: Intel NIC x710 2p10GE.
447 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
448 - Quantity: 3 servers.
449 - Physical connectivity:
450 - CIMC and host management ports.
451 - no NIC ports, standalone setup.
452 - Main HW configuration:
453 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
454 - Processors: 2* E5-2699v3 2.3 GHz.
455 - RAM Memory: 16* 32GB DDR4-2133MHz.
456 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
457 - NICs configuration:
458 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
460 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
463 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
465 - Physical connectivity:
466 - IPMI and host management ports.
467 - NIC ports connected into 2-node and 3-node topologies.
468 - Main HW configuration:
469 - Chassis: SuperMicro SYS-7049GP-TRT.
470 - Motherboard: SuperMicro X11DPG-QT.
471 - Processors: 2* Intel Platinum 8180 2.5 GHz.
472 - RAM Memory: 16* 16GB DDR4-2666MHz.
473 - Disks: 2* 1.6TB 6G SATA SSD.
474 - NICs configuration:
475 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
476 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
477 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
478 - PCIe Slot9 5e:00.xx: empty.
479 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
480 - PCIe Slot6 86:00.xx: empty.
481 - PCIe Slot8 af:00.xx: empty.
482 - PCIe Slot10 d8:00.xx: empty.
483 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
485 - Physical connectivity:
486 - IPMI and host management ports.
487 - NIC ports connected into 2-node and 3-node topologies.
488 - Main HW configuration:
489 - Chassis: SuperMicro SYS-7049GP-TRT.
490 - Motherboard: SuperMicro X11DPG-QT.
491 - Processors: 2* Intel Platinum 8180 2.5 GHz.
492 - RAM Memory: 16* 16GB DDR4-2666MHz.
493 - Disks: 2* 1.6TB 6G SATA SSD.
494 - NICs configuration:
495 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
496 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
497 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
498 - PCIe Slot9 5e:00.xx: empty.
499 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
500 - PCIe Slot6 86:00.xx: empty.
501 - PCIe Slot8 af:00.xx: empty.
502 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
503 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
505 - Physical connectivity:
506 - IPMI(?) and host management ports.
507 - NIC ports connected into 3-node topology.
508 - Main HW configuration:
509 - Chassis: Huawei TaiShan 2280.
510 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
511 - RAM Memory: 8* 16GB DDR4-2400MT/s
512 - Disks: 1* 4TB SATA HDD
513 - NICs configuration:
514 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
515 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
516 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
518 - Physical connectivity:
519 - Host management ports.
520 - NIC ports connected into 2-node and 3-node topologies.
521 - Main HW configuration:
522 - Chassis: MACCHIATObin.
523 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
524 - RAM Memory: 1* 16GB DDR4
525 - Disks: 1* 128GB(?) SATA SDD
526 - NICs configuration:
527 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
528 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
529 - Quantity: TBD based on testbed allocation.
530 - Physical connectivity:
531 - Management: serial Port (usb) for console
532 - NIC ports connected into 2-node.
533 - Main HW configuration:
534 - Chassis: Netgate XG-2758-1u
535 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
536 - RAM Memory: 16GB ECC
538 - NICs configuration:
539 - 2x 10Gb Intel 82599ES
541 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
543 - Physical connectivity:
544 - IPMI and host management ports.
545 - NIC ports connected into 2-node and 3-node topologies.
546 - Main HW configuration:
547 - Chassis: SuperMicro SYS-7049GP-TRT.
548 - Motherboard: SuperMicro X11DPG-QT.
549 - Processors: 2* Intel Platinum 8180 2.5 GHz.
550 - RAM Memory: 16* 16GB DDR4-2666MHz.
551 - Disks: 2* 1.6TB 6G SATA SSD.
552 - NICs configuration:
553 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
554 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
555 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
556 - PCIe Slot9 5e:00.xx: empty.
557 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
558 - PCIe Slot6 86:00.xx: empty.
559 - PCIe Slot8 af:00.xx: empty.
560 - PCIe Slot10 d8:00.xx: empty.
561 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
563 - Physical connectivity:
564 - Host management interface: 10/100/1000-BaseT.
565 - 8-port 10GE SFP+ integrated NIC.
566 - Main HW configuration:
567 - Chassis: PS10GE4NG.
568 - Motherboard: SuperMicro X11DPG-QT.
569 - Processors: Quad-Core, Intel Processor.
570 - HW accelerators: FPGA offload.
572 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
573 - Physical Interfaces: 4 * 10GE SFP+.
574 - Operating System: Native IxOS.
575 - Interface configuration:
580 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
582 - Physical connectivity:
583 - IPMI and host management ports.
585 - Main HW configuration:
586 - Chassis: SuperMicro SYS-7049GP-TRT.
587 - Motherboard: SuperMicro X11DPG-QT.
588 - Processors: 2* Intel Platinum 8180 2.5 GHz.
589 - RAM Memory: 16* 16GB DDR4-2666MHz.
590 - Disks: 2* 1.6TB 6G SATA SSD.
591 - NICs configuration:
592 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
593 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
594 - PCIe Slot4 3b:00.xx: empty.
595 - PCIe Slot9 5e:00.xx: empty.
596 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
597 - PCIe Slot6 86:00.xx: empty.
598 - PCIe Slot8 af:00.xx: empty.
599 - PCIe Slot10 d8:00.xx: empty.
600 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
602 - Physical connectivity:
603 - IPMI and host management ports.
604 - NIC ports connected into 1-node topologies.
605 - Main HW configuration:
606 - Chassis: Gigabyte R181-T90 1U
607 - Motheboard: MT91-FS1
608 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
609 - RAM Memory: 4* 32GB RDIMM
610 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
611 - NICs configuration:
613 - PCIe Slot1 05:00.xx: XL710-QDA2.
614 - PCIe Slot3 08:00.xx: XL710-QDA2.
616 - PCIe Slot6 85:00.xx: XL710-QDA2.
617 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
619 - Physical connectivity:
620 - IPMI and host management ports.
622 - Main HW configuration:
623 - Chassis: SuperMicro SYS-E300-9A
624 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
625 - RAM Memory: 32GB ECC
627 - NICs configuration:
628 - 2x 10Gb Intel x553 fiber ports
629 - 2x 10Gb Intel x553 copper ports
630 - 4x 1GB Intel I350 ports
631 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
633 - Physical connectivity:
634 - IPMI and host management ports.
635 - NIC ports connected into 1-node testbed topologies.
636 - Main HW configuration:
637 - Chassis: SuperMicro SYS-7049GP-TRT.
638 - Motherboard: SuperMicro X11DPG-QT.
639 - Processors: 2* Intel Platinum 8280 2.7 GHz.
640 - RAM Memory: 12* 16GB DDR4-2933.
641 - Disks: 2* 1.92TB SATA SSD.
642 - NICs configuration:
643 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
644 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
645 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
646 - PCIe Slot9 5e:00.xx: empty.
647 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
648 - PCIe Slot6 86:00.xx: empty.
649 - PCIe Slot8 af:00.xx: empty.
650 - PCIe Slot10 d8:00.xx: empty.
651 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
653 - Physical connectivity:
654 - IPMI and host management ports.
655 - NIC ports connected into 2-node testbed topologies.
656 - Main HW configuration:
657 - Chassis: SuperMicro SYS-7049GP-TRT.
658 - Motherboard: SuperMicro X11DPG-QT.
659 - Processors: 2* Intel Gold 6252N 2.3 GHz.
660 - RAM Memory: 12* 16GB DDR4-2933.
661 - Disks: 2* 1.92TB SATA SSD.
662 - NICs configuration:
663 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
664 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
665 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
666 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
667 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
668 - PCIe Slot6 86:00.xx: empty.
669 - PCIe Slot8 af:00.xx: empty.
670 - PCIe Slot10 d8:00.xx: empty.
671 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
673 - Physical connectivity:
674 - IPMI and host management ports.
675 - NIC ports connected into 2-node testbed topologies.
676 - Main HW configuration:
677 - Chassis: SuperMicro SYS-7049GP-TRT.
678 - Motherboard: SuperMicro X11DPG-QT.
679 - Processors: 2* Intel Platinum 8280 2.7 GHz.
680 - RAM Memory: 12* 16GB DDR4-2933.
681 - Disks: 2* 1.92TB SATA SSD.
682 - NICs configuration:
683 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
684 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
685 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
686 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
687 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
688 - PCIe Slot6 86:00.xx: empty.
689 - PCIe Slot8 af:00.xx: empty.
690 - PCIe Slot10 d8:00.xx: empty.
691 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
693 - Physical connectivity:
694 - CIMC and host management ports.
695 - no NIC ports, standalone setup.
696 - Main HW configuration:
697 - Chassis: SuperMicro 1029P-WTRT.
698 - Motherboard: SuperMicro X11DDW-NT.
699 - Processors: 2* Intel Platinum 8280 2.7 GHz.
700 - RAM Memory: 12* 16GB DDR4-2933.
701 - Disks: 4* 1.92TB SATA SSD.
702 - NICs configuration:
707 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
709 - Physical connectivity:
710 - IPMI and host management ports.
711 - NIC ports connected into 2-node testbed topologies.
712 - Main HW configuration:
713 - Chassis: SuperMicro AS-1114S-WTRT
714 - Processors: 1* AMD EPYC 7532 2.4 GHz.
715 - RAM Memory: 8* 32GB DDR4-2933.
716 - Disks: 1* 1TB SATA SSD.
717 - NICs configuration:
718 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
719 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
720 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
721 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
722 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
724 - Physical connectivity:
725 - IPMI and host management ports.
726 - NIC ports connected into 2-node testbed topologies.
727 - Main HW configuration:
728 - Chassis: SuperMicro AS-1114S-WTRT
729 - Processors: 1* AMD EPYC 7532 2.4 GHz.
730 - RAM Memory: 8* 32GB DDR4-2933.
731 - Disks: 1* 1TB SATA SSD.
732 - NICs configuration:
733 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
734 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
735 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
736 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
739 ### Naming Convention
741 Following naming convention is used within this page to specify physical
742 connectivity and wiring across defined CSIT testbeds:
745 - testbedname: testbedN.
747 - traffic-generator: tN-tgW.
748 - system-under-testX: tN-sutX.
753 - N - testbed number.
754 - tgW - server acts as traffic-generator with W index.
755 - sutX - server acts as system-under-test with X index.
756 - Y - PCIe slot number denoting a NIC card number within the host.
757 - Z - port number on the NIC card.
760 ## Testbeds Configuration
762 ### Per Testbed Server Allocation and Naming
764 #### 1-Node-Skylake Servers (1n-skx) PROD
767 - SUT [Server-Type-B6]:
768 - testbedname: testbed11.
769 - hostname: s1-t11-sut1.
770 - IPMI IP: 10.30.50.47
771 - Host IP: 10.30.51.50
773 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
774 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
775 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
776 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
777 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
778 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
779 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
780 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
781 - SUT [Server-Type-B6]:
782 - testbedname: testbed12.
783 - hostname: s2-t12-sut1.
784 - IPMI IP: 10.30.50.48
785 - Host IP: 10.30.51.51
787 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
788 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
789 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
790 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
791 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
792 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
793 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
794 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
797 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
800 - SUT [Server-Type-B9]:
801 - testbedname: testbed13.
802 - hostname: s27-t13-sut1.
803 - IPMI IP: 10.30.50.69
804 - Host IP: 10.30.51.69
806 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
807 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
808 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
809 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
810 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
811 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
814 #### 1-Node-Cascadelake Servers (1n-clx) PROD
817 - SUT [Server-Type-C1]:
818 - testbedname: testbed11.
819 - hostname: s32-t14-sut1.
820 - IPMI IP: 10.30.55.17
821 - Host IP: 10.32.8.17
823 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
824 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
825 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
826 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
827 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
828 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
829 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
830 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
833 #### 2-Node-Skylake Servers (2n-skx) PROD
836 - SUT [Server-Type-B1]:
837 - testbedname: testbed21.
838 - hostname: s3-t21-sut1.
839 - IPMI IP: 10.30.50.41
840 - Host IP: 10.30.51.44
842 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
843 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
844 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
845 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
846 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
847 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
848 - TG [Server-Type-B2]:
849 - testbedname: testbed21.
850 - hostname: s4-t21-tg1.
851 - IPMI IP: 10.30.50.42
852 - Host IP: 10.30.51.45
854 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
855 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
856 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
857 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
858 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
859 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
860 - SUT [Server-Type-B1]:
861 - testbedname: testbed22.
862 - hostname: s5-t22-sut1.
863 - IPMI IP: 10.30.50.49
864 - Host IP: 10.30.51.52
866 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
867 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
868 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
869 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
870 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872 - TG [Server-Type-B2]:
873 - testbedname: testbed22.
874 - hostname: s6-t22-tg1.
875 - IPMI IP: 10.30.50.50
876 - Host IP: 10.30.51.53
878 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
879 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
880 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
881 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
882 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
883 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
884 - SUT [Server-Type-B1]:
885 - testbedname: testbed23.
886 - hostname: s7-t23-sut1.
887 - IPMI IP: 10.30.50.51
888 - Host IP: 10.30.51.54
890 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
891 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
892 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
893 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
894 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
895 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
896 - TG [Server-Type-B2]:
897 - testbedname: testbed23.
898 - hostname: s8-t23-tg1.
899 - IPMI IP: 10.30.50.52
900 - Host IP: 10.30.51.55
902 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
903 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
904 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
905 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
906 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
907 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
908 - SUT [Server-Type-B1]:
909 - testbedname: testbed24.
910 - hostname: s9-t24-sut1.
911 - IPMI IP: 10.30.50.53
912 - Host IP: 10.30.51.56
914 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
915 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
916 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
917 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
918 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
919 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
920 - TG [Server-Type-B2]:
921 - testbedname: testbed24.
922 - hostname: s10-t24-tg1.
923 - IPMI IP: 10.30.50.54
924 - Host IP: 10.30.51.57
926 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
927 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
928 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
929 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
930 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
931 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934 #### 2-Node-Denverton Servers (2n-dnv) WIP
936 Note: ServerB28 (TG) is shared between testbed26 & testbed35
939 - TG [Server-Type-B2]:
940 - testbednames: testbed26 and testbed35.
941 - hostname: s28-t26t35-tg1.
942 - IPMI IP: 10.30.55.10
943 - Host IP: 10.32.8.10
945 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
946 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
947 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
948 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
949 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
950 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
951 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
952 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
953 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
954 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
955 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
956 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
957 - SUT [Server-Type-B10]:
958 - testbednames: testbed26.
959 - hostname: s29-t26-sut1.
960 - IPMI IP: 10.30.55.11
961 - Host IP: 10.32.8.11
963 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
964 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
965 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
966 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
969 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
972 - SUT [Server-Type-B8]:
973 - testbedname: testbed25.
974 - hostname: s25-t25-sut1.
975 - IPMI IP: 10.30.50.58
976 - Host IP: 10.30.51.61
978 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
979 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
980 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
981 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
982 - TG [Server-Type-B7]:
983 - testbedname: testbed25.
984 - hostname: s26-t25-tg1.
985 - IPMI IP: 10.30.50.59
986 - Host IP: 10.30.51.62
988 - s26-t25-tg1-p1 - 10GE-port1.
989 - s26-t25-tg1-p2 - 10GE-port2.
990 - s26-t25-tg1-p3 - 10GE-port3.
991 - s26-t25-tg1-p4 - 10GE-port4.
994 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
997 - SUT [Server-Type-C2]:
998 - testbedname: testbed27.
999 - hostname: s33-t27-sut1.
1000 - IPMI IP: 10.30.55.18
1001 - Host IP: 10.32.8.18
1003 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1004 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1005 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1006 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1007 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1008 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1009 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1010 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1011 - TG [Server-Type-C3]:
1012 - testbedname: testbed27.
1013 - hostname: s34-t27-tg1.
1014 - IPMI IP: 10.30.55.19
1015 - Host IP: 10.32.8.19
1017 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1018 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1019 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1020 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1021 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1022 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1023 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1024 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1025 - SUT [Server-Type-C2]:
1026 - testbedname: testbed28.
1027 - hostname: s35-t28-sut1.
1028 - IPMI IP: 10.30.55.20
1029 - Host IP: 10.32.8.20
1031 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1032 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1033 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1034 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1035 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1036 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1037 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1038 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1039 - TG [Server-Type-C3]:
1040 - testbedname: testbed28.
1041 - hostname: s36-t28-tg1.
1042 - IPMI IP: 10.30.55.21
1043 - Host IP: 10.32.8.21
1045 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1046 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1047 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1048 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1049 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1050 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1051 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1052 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1053 - SUT [Server-Type-C2]:
1054 - testbedname: testbed29.
1055 - hostname: s37-t29-sut1.
1056 - IPMI IP: 10.30.55.22
1057 - Host IP: 10.32.8.22
1059 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1060 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1061 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1062 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1063 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1064 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1065 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1066 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1067 - TG [Server-Type-C3]:
1068 - testbedname: testbed29.
1069 - hostname: s38-t29-tg1.
1070 - IPMI IP: 10.30.55.23
1071 - Host IP: 10.32.8.23
1073 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1074 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1075 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1076 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1077 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1078 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1079 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1080 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1083 #### 2-Node-Zen2 Servers (2n-zn2) SETUP
1086 - SUT [Server-Type-D1]:
1087 - testbedname: testbed210.
1088 - hostname: s60-t210-sut1.
1089 - IPMI IP: 10.30.55.24
1090 - Host IP: 10.32.8.24
1092 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1093 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1094 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1095 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1096 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1097 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1098 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1099 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1100 - TG [Server-Type-D2]:
1101 - testbedname: testbed210.
1102 - hostname: s61-t210-tg1.
1103 - IPMI IP: 10.30.55.25
1104 - Host IP: 10.32.8.25
1106 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1107 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1108 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1109 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1110 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1111 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1112 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1113 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1116 #### 3-Node-Haswell Servers (3n-hsw) PROD
1119 1. SUT [Server-Type-A1]:
1120 - testbedname: testbed1.
1121 - hostname: t1-sut1.
1122 - CIMC IP: 10.30.50.17
1123 - Host IP: 10.30.51.17
1125 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1126 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1127 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1128 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1129 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1130 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1131 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1132 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1133 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1134 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1135 2. SUT [Server-Type-A1]:
1136 - testbedname: testbed1.
1137 - hostname: t1-sut2.
1138 - CIMC IP: 10.30.50.18
1139 - Host IP: 10.30.51.18
1141 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1142 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1143 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1144 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1145 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1146 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1147 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1148 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1149 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1150 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1151 3. TG [Server-Type-A2]:
1152 - testbedname: testbed1.
1154 - CIMC IP: 10.30.50.16
1155 - Host IP: 10.30.51.16
1157 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1158 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1159 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1160 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1161 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1162 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1163 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1164 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1165 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1166 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1167 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1168 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1169 4. SUT [Server-Type-A1]:
1170 - testbedname: testbed2.
1171 - hostname: t2-sut1.
1172 - CIMC IP: 10.30.50.21
1173 - Host IP: 10.30.51.21
1175 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1176 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1177 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1178 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1179 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1180 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1181 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1182 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1183 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1184 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1185 5. SUT [Server-Type-A1]:
1186 - testbedname: testbed2.
1187 - hostname: t2-sut2.
1188 - CIMC IP: 10.30.50.22
1189 - Host IP: 10.30.51.22
1191 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1192 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1193 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1194 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1195 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1196 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1197 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1198 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1199 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1200 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1201 6. TG [Server-Type-A2]:
1202 - testbedname: testbed2.
1204 - CIMC IP: 10.30.50.20
1205 - Host IP: 10.30.51.20
1207 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1208 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1209 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1210 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1211 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1212 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1213 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1214 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1215 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1216 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1217 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1218 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1219 7. SUT [Server-Type-A1]:
1220 - testbedname: testbed3.
1221 - hostname: t3-sut1.
1222 - CIMC IP: 10.30.50.25
1223 - Host IP: 10.30.51.25
1225 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1226 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1227 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1228 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1229 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1230 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1231 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1232 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1233 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1234 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1235 8. SUT [Server-Type-A1]:
1236 - testbedname: testbed3.
1237 - hostname: t3-sut2.
1238 - CIMC IP: 10.30.50.26
1239 - Host IP: 10.30.51.26
1241 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1242 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1243 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1244 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1245 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1246 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1247 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1248 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1249 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1250 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1251 9. TG [Server-Type-A2]:
1252 - testbedname: testbed3.
1254 - CIMC IP: 10.30.50.24
1255 - Host IP: 10.30.51.24
1257 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1258 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1259 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1260 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1261 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1262 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1263 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1264 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1265 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1266 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1267 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1268 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1271 #### 3-Node-Skylake Servers (3n-skx) PROD
1274 - ServerB11 [Server-Type-B1]:
1275 - testbedname: testbed31.
1276 - hostname: s11-t31-sut1.
1277 - IPMI IP: 10.30.50.43
1278 - Host IP: 10.30.51.46
1280 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1281 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1282 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1283 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1284 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1285 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1286 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1287 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1288 - ServerB12 [Server-Type-B1]:
1289 - testbedname: testbed31.
1290 - hostname: s12-t31-sut2.
1291 - IPMI IP: 10.30.50.44
1292 - Host IP: 10.30.51.47
1294 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1295 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1296 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1297 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1298 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1299 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1300 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1301 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1302 - ServerB13 [Server-Type-B2]:
1303 - testbedname: testbed31.
1304 - hostname: s13-t31-tg1.
1305 - IPMI IP: 10.30.50.45
1306 - Host IP: 10.30.51.48
1308 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1309 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1310 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1311 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1312 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1313 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1314 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1315 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1316 - ServerB14 [Server-Type-B1]:
1317 - testbedname: testbed32.
1318 - hostname: s14-t32-sut1.
1319 - IPMI IP: 10.30.50.55
1320 - Host IP: 10.30.51.58
1322 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1323 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1324 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1325 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1326 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1327 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1328 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1329 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1330 - ServerB15 [Server-Type-B1]:
1331 - testbedname: testbed32.
1332 - hostname: s15-t32-sut2.
1333 - IPMI IP: 10.30.50.56
1334 - Host IP: 10.30.51.59
1336 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1337 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1338 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1339 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1340 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1341 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1342 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1343 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1344 - ServerB16 [Server-Type-B2]:
1345 - testbedname: testbed32.
1346 - hostname: s16-t32-tg1.
1347 - IPMI IP: 10.30.50.57
1348 - Host IP: 10.30.51.60
1350 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1351 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1352 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1353 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1354 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1355 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1356 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1357 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1360 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1362 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1365 - ServerB22 [Server-Type-B5]:
1366 - testbedname: testbed35.
1367 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1368 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1369 - Host IP: 10.30.51.9
1371 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1372 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1374 - ServerB23 [Server-Type-B5]:
1375 - testbedname: testbed35.
1376 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1377 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1378 - Host IP: 10.30.51.10
1380 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1381 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1383 - ServerB24 [Server-Type-B5]:
1384 - testbedname: testbed35.
1385 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1386 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1387 - Host IP: 10.30.51.11
1389 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1390 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1394 #### 3-Node-Taishan Servers (3n-tsh) WIP
1396 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1399 - ServerB17 [Server-Type-B3]:
1400 - testbedname: testbed33.
1401 - hostname: s17-t33-sut1.
1402 - IPMI IP: 10.30.50.36
1403 - Host IP: 10.30.51.36
1405 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1406 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1407 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1408 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1409 - ServerB18 [Server-Type-B3]:
1410 - testbedname: testbed33.
1411 - hostname: s18-t33-sut2.
1412 - IPMI IP: 10.30.50.37
1413 - Host IP: 10.30.51.37
1415 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1416 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1417 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1418 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1419 - ServerB19 [Server-Type-B2]:
1420 - testbednames: testbed33 and testbed34.
1421 - hostname: s19-t33t34-tg1.
1422 - IPMI IP: 10.30.50.46
1423 - Host IP: 10.30.51.49
1425 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1426 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1427 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1428 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1429 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1430 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1431 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1432 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1433 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1434 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1435 - ServerB20 [Server-Type-B4]:
1436 - testbedname: testbed34.
1437 - hostname: s20-t34-sut1.
1439 - Host IP: 10.30.51.41
1441 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1442 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1443 - ServerB21 [Server-Type-B4]:
1444 - testbedname: testbed34.
1445 - hostname: s21-t34-sut2.
1447 - Host IP: 10.30.51.42
1449 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1450 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1453 #### 3-Node-Denverton Servers (3n-dnv) WIP
1456 - ServerB30 [Server-Type-B10]:
1457 - testbednames: testbed35.
1458 - hostname: s30-t35-sut1.
1459 - IPMI IP: 10.30.55.12
1460 - Host IP: 10.32.8.12
1462 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1463 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1464 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1465 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1466 - ServerB31 [Server-Type-B10]:
1467 - testbednames: testbed35.
1468 - hostname: s31-t35-sut2.
1469 - IPMI IP: 10.30.55.13
1470 - Host IP: 10.32.8.13
1472 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1473 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1474 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1475 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1478 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1484 ### Per Testbed Wiring
1486 #### 1-Node-Skylake Wiring (1n-skx) PROD
1490 - ring1 10GE-ports x710-4p10GE:
1491 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1492 - ring2 10GE-ports x710-4p10GE:
1493 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1494 - ring3 10GE-ports x710-4p10GE:
1495 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1496 - ring4 10GE-ports x710-4p10GE:
1497 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1499 - ring1 10GE-ports x710-4p10GE:
1500 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1501 - ring2 10GE-ports x710-4p10GE:
1502 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1503 - ring3 10GE-ports x710-4p10GE:
1504 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1505 - ring4 10GE-ports x710-4p10GE:
1506 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1509 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1513 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1514 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1515 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1516 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1517 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1518 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1521 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1525 - ring1 10GE-ports x710-4p10GE:
1526 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1527 - ring2 10GE-ports x710-4p10GE:
1528 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1529 - ring3 10GE-ports x710-4p10GE:
1530 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1531 - ring4 10GE-ports x710-4p10GE:
1532 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1535 #### 2-Node-Skylake Wiring (2n-skx) PROD
1539 - ring1 10GE-ports x710-4p10GE on SUT:
1540 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1541 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1542 - ring2 10GE-ports x710-4p10GE on SUT:
1543 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1544 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1545 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1546 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1547 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1549 - ring1 10GE-ports x710-4p10GE on SUT:
1550 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1551 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1552 - ring2 10GE-ports x710-4p10GE on SUT:
1553 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1554 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1555 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1556 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1557 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1559 - ring1 10GE-ports x710-4p10GE on SUT:
1560 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1561 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1562 - ring2 10GE-ports x710-4p10GE on SUT:
1563 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1564 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1565 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1566 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1567 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1569 - ring1 10GE-ports x710-4p10GE on SUT:
1570 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1571 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1572 - ring2 10GE-ports x710-4p10GE on SUT:
1573 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1574 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1575 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1576 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1577 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1580 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1584 - ring1 10GE-ports x553 copper port on SUT:
1585 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1586 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1587 - ring2 10GE-ports x553 fiber port on SUT:
1588 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1589 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1592 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1596 - link1 10GE-port x710-4p10GE on SUT:
1597 - t25-tg1-p1 to t25-sut1-c2/p1.
1598 - link2 10GE-port x710-4p10GE on SUT:
1599 - t25-tg1-p2 to t25-sut1-c2/p2.
1600 - link3 10GE-port x710-4p10GE on SUT:
1601 - t25-tg1-p3 to t25-sut1-c2/p3.
1602 - link4 10GE-port x710-4p10GE on SUT:
1603 - t25-tg1-p4 to t25-sut1-c2/p4.
1606 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1610 - ring1 10GE-ports x710-4p10GE on SUT:
1611 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1612 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1613 - ring2 10GE-ports x710-4p10GE on SUT:
1614 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1615 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1616 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1617 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1618 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1619 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1620 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1621 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1623 - ring1 10GE-ports x710-4p10GE on SUT:
1624 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1625 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1626 - ring2 10GE-ports x710-4p10GE on SUT:
1627 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1628 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1629 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1630 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1631 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1632 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1633 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1634 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1636 - ring1 10GE-ports x710-4p10GE on SUT:
1637 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1638 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1639 - ring2 10GE-ports x710-4p10GE on SUT:
1640 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1641 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1642 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1643 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1644 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1645 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1646 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1647 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1650 #### 2-Node-Zen2 Wiring (2n-zen2) SETUP
1654 - ring1 10GE-ports x710-4p10GE on SUT:
1655 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1656 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1657 - ring2 10GE-ports x710-4p10GE on SUT:
1658 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1659 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1660 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1661 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1662 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1663 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1664 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1665 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1668 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1672 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1673 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1674 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1675 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1676 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1677 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1678 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1679 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1680 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1681 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1682 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1683 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1684 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1685 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1686 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1687 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1688 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1689 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1690 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1691 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1692 - TG loopback ports Intel NIC x710 2p10GE
1693 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1696 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1697 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1698 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1699 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1700 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1701 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1702 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1703 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1704 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1705 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1706 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1707 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1708 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1709 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1710 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1711 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1712 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1713 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1714 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1715 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1716 - TG loopback ports Intel NIC x710 2p10GE
1717 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1720 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1721 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1722 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1723 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1724 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1725 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1726 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1727 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1728 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1729 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1730 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1731 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1732 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1733 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1734 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1735 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1736 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1737 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1738 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1739 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1740 - TG loopback ports Intel NIC x710 2p10GE
1741 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1744 #### 3-Node-Skylake Wiring (3n-skx) PROD
1748 - ring1 10GE-ports x710-4p10GE on SUTs:
1749 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1750 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1751 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1752 - ring2 10GE-ports x710-4p10GE on SUT:
1753 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1754 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1755 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1756 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1757 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1758 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1759 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1760 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1761 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1762 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1763 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1764 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1765 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1766 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1768 - ring1 10GE-ports x710-4p10GE on SUTs:
1769 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1770 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1771 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1772 - ring2 10GE-ports x710-4p10GE on SUT:
1773 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1774 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1775 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1776 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1777 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1778 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1779 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1780 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1781 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1782 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1783 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1784 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1785 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1786 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1789 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1795 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1799 - ring1 10GE-ports x520-2p10GE on SUTs:
1800 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1801 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1802 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1803 - ring2 25GE-ports cx4-2p25GE on SUTs:
1804 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1805 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1806 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1809 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1813 - ring1 10GE-ports Marvell on SUTs:
1814 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1815 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1816 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1819 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1823 - ring1 10GE-ports x553 copper port on SUTs:
1824 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1825 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1826 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1827 - ring2 10GE-ports x553 fiber port on SUTs:
1828 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1829 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1830 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1838 1. Ixia PerfectStorm One Appliance
1840 - Chassis: PS10GE4NG.
1841 - Motherboard: SuperMicro X11DPG-QT.
1842 - Processors: Quad-Core, Intel Processor.
1843 - HW accelerators: FPGA offload.
1845 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1846 - Physical Interfaces: 4 * 10GE SFP+.
1847 - Operating System: Native IxOS.
1853 1. Arm Cortex A-72 servers
1855 - Chassis: Marvell ThunderX2
1856 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1857 - RAM Memory: 4* 32GB RDIMM
1858 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1859 - 2 * Huawei TaiShan 2280.
1860 - Chassis: Huawei TaiShan 2280.
1861 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1862 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1863 - Disks: 1* 4TB SATA HDD.
1865 - Chassis: MACCHIATObin.
1866 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1867 - RAM Memory: 1* 16GB DDR4.
1868 - Disks: 1* 128GB(?) SATA SDD.
1871 ### Xeon and Atom Servers
1874 1. Intel Xeon servers:
1875 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1876 - Chassis: SuperMicro SYS-7049GP-TRT.
1877 - Motherboard: SuperMicro X11DPG-QT.
1878 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1879 - RAM Memory: 16* 16GB DDR4-2666MHz.
1880 - Disks: 2* 1.6TB 6G SATA SSD.
1881 2. Intel Atom servers with Rangely processors.
1882 - 3 * Netgate XG-2758-1u
1883 - Chassis: Netgate XG-2758-1u
1884 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1885 - RAM Memory: 16GB ECC
1889 ### Network Interface Cards
1893 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1894 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1895 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1897 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1899 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1901 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1904 ### Pluggables and Cables
1910 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1911 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1917 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1928 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable