1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
17 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
18 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
34 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
36 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
37 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
38 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
39 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
41 1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
48 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
51 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
52 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
53 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
54 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
55 1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2
75 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0
76 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0
77 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0
78 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0
79 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0
80 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0
81 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0
82 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0
83 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0
84 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0
85 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0
86 12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0
87 13. 3-Node-Altra perf alt tbd 1 2 tbd 0 0 0 0 0 0 0 2 0 0
88 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0
89 15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2
90 Totals: 26 33 15 4 19 1 2 3 3 2 2 7 2
93 ### 1-Node-Skylake Xeon Intel (1n-skx)
95 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
96 ports connected back-to-back ([Server Types](#server-types)).
97 Used for FD.io VPP_Device functional driver tests.
99 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
101 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
102 ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
105 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
107 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
108 NIC ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
112 ### 2-Node-Skylake Xeon Intel (2n-skx)
114 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
115 (Server-Type-B2) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
147 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
149 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
150 one TG (Server-Type-E31) connected in a 2-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
154 ### 3-Node-Haswell Xeon Intel (3n-hsw)
156 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
157 TG (Server-Type-A2) connected in a 3-node circular topology
158 ([Server Types](#server-types)).
159 Used for FD.io performance tests.
161 ### 3-Node-Skylake Xeon Intel (3n-skx)
163 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
164 TG (Server-Type-B2) connected in a 3-node circular topology.
165 Used for FD.io performance tests.
167 ### 3-Node-Rangeley Atom Testbeds
169 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
170 TG (Server-Type-2) connected in a 3-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
174 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
176 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
177 TG (Server-Type-E31) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
181 ### 3-Node-Altra Arm Ampere (3n-alt)
183 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
184 TG (TBD Server-Type-xxx) connected in a 3-node circular topology
185 ([Server Types](#server-types)).
186 Used for FD.io performance tests.
192 For management purposes, each server must have following two ports
193 connected to the management network:
197 - IPMI - Intelligent Platform Management Interface.
198 - Required for access to embedded server management with WebUI, CLI,
199 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
200 - 1GE/10GE/40GE management port
201 - hostOS management port for general system management.
206 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
207 Management port, which are connected to two different VLANs.
211 - Subnet: 10.30.50.0/24
212 - Gateway: 10.30.50.1
213 - Broadcast: 10.30.50.255
214 - DNS1: 199.204.44.24
215 - DNS2: 199.204.47.54
217 - Subnet: 10.30.51.0/24
218 - Gateway: 10.30.51.1
219 - Broadcast: 10.30.51.255
220 - DNS1: 199.204.44.24
221 - DNS2: 199.204.47.54
224 To access these hosts, VPN connection is required.
226 ### LOM (IPMI) VLAN IP Addresses
229 ------------ | -------
232 10.30.50.2 | LF Reserved
233 10.30.50.3 | LF Reserved
234 10.30.50.4 | LF Reserved
235 10.30.50.5 | LF Reserved
236 10.30.50.6 | LF Reserved
237 10.30.50.7 | LF Reserved
238 10.30.50.8 | LF Reserved
239 10.30.50.9 | LF Reserved
240 10.30.50.10 | LF Reserved
241 10.30.50.11 | LF Reserved
242 10.30.50.12 | LF Reserved
243 10.30.50.13 | LF Reserved
244 10.30.50.14 | LF Reserved
245 10.30.50.15 | LF Reserved
246 10.30.50.22 | s42-nomad
247 10.30.50.24 | s43-nomad
248 10.30.50.25 | s44-nomad
249 10.30.50.26 | s45-nomad
250 10.30.50.28 | s41-nomad
251 10.30.50.29 | s39-nomad
252 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
253 10.30.50.30 | s40-nomad
254 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
255 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
256 10.30.50.36 | s17-t33-sut1
257 10.30.50.37 | s18-t33-sut2
258 10.30.50.38 | fdio-marvell-dev
259 10.30.50.39 | s53-nomad
260 10.30.50.40 | s54-nomad
261 10.30.50.41 | s3-t21-sut1
262 10.30.50.42 | s4-t21-tg1
263 10.30.50.43 | s11-t31-sut1
264 10.30.50.44 | s12-t31-sut2
265 10.30.50.45 | s13-t31-tg1
266 10.30.50.46 | s19-t33t211-tg1
267 10.30.50.47 | s1-t11-sut1
268 10.30.50.48 | s2-t12-sut1
269 10.30.50.49 | s5-t22-sut1
270 10.30.50.50 | s6-t22-tg1
271 10.30.50.51 | s7-t23-sut1
272 10.30.50.52 | s8-t23-tg1
273 10.30.50.53 | s9-t24-sut1
274 10.30.50.54 | s10-t24-tg1
275 10.30.50.55 | s14-t32-sut1
276 10.30.50.56 | s15-t32-sut2
277 10.30.50.57 | s16-t32-tg1
278 10.30.50.58 | s25-t25-sut1
279 10.30.50.59 | s26-t25-tg1
280 10.30.50.65 | s52-nomad
281 10.30.50.66 | s51-nomad
282 10.30.50.67 | s49-nomad
283 10.30.50.68 | s50-nomad
284 10.30.50.69 | s27-t211-sut1
285 10.30.50.70 | s55-t13-sut1
286 10.30.50.71 | s56-t14-sut1
287 10.30.50.72 | s62-t34-sut1
288 10.30.50.73 | s63-t34-sut2
289 10.30.50.74 | s64-t34-tg1
290 10.30.50.255 | Broadcast
293 10.30.55.10 | s28-t26t35-tg1
294 10.30.55.11 | s29-t26-sut1
295 10.30.55.12 | s30-t35-sut1
296 10.30.55.13 | s31-t35-sut2
297 10.30.55.14 | s46-nomad
298 10.30.55.15 | s47-nomad
299 10.30.55.16 | s48-nomad
300 10.30.55.17 | s57-nomad
301 10.30.55.18 | s33-t27-sut1
302 10.30.55.19 | s34-t27-tg1
303 10.30.55.20 | s35-t28-sut1
304 10.30.55.21 | s36-t28-tg1
305 10.30.55.22 | s37-t29-sut1
306 10.30.55.23 | s38-t29-tg1
307 10.30.55.24 | s60-t210-sut1
308 10.30.55.25 | s61-t210-tg1
309 10.30.55.255 | Broadcast
311 ### Management VLAN IP Addresses
314 ------------------------- | -------
317 10.30.51.2 | LF Reserved
318 10.30.51.3 | LF Reserved
319 10.30.51.4 | LF Reserved
320 10.30.51.5 | LF Reserved
321 10.30.51.6 | LF Reserved
322 10.30.51.7 | LF Reserved
323 10.30.51.8 | LF Reserved
324 10.30.51.15 | LF Reserved
325 10.30.51.22 | s42-nomad
326 10.30.51.24 | s43-nomad
327 10.30.51.25 | s44-nomad
328 10.30.51.26 | s45-nomad
329 10.30.51.28 | s41-nomad
330 10.30.51.29 | s39-nomad
331 10.30.51.30 | s40-nomad
332 10.30.51.36 | s17-t33-sut1
333 10.30.51.37 | s18-t33-sut2
334 10.30.51.38 | fdio-marvell-dev
335 10.30.51.39 | s53-nomad
336 10.30.51.40 | s54-nomad
337 10.30.51.44 | s3-t21-sut1
338 10.30.51.45 | s4-t21-tg1
339 10.30.51.46 | s11-t31-sut1
340 10.30.51.47 | s12-t31-sut2
341 10.30.51.48 | s13-t31-tg1
342 10.30.51.49 | s19-t33t211-tg1
343 10.30.51.50 | s1-t11-sut1
344 10.30.51.51 | s2-t12-sut1
345 10.30.51.52 | s5-t22-sut1
346 10.30.51.53 | s6-t22-tg1
347 10.30.51.54 | s7-t23-sut1
348 10.30.51.55 | s8-t23-tg1
349 10.30.51.56 | s9-t24-sut1
350 10.30.51.57 | s10-t24-tg1
351 10.30.51.58 | s14-t32-sut1
352 10.30.51.59 | s15-t32-sut2
353 10.30.51.60 | s16-t32-tg1
354 10.30.51.61 | s25-t25-sut1
355 10.30.51.62 | s26-t25-tg1
356 10.30.51.65 | s52-nomad
357 10.30.51.66 | s51-nomad
358 10.30.51.67 | s49-nomad
359 10.30.51.68 | s50-nomad
360 10.30.51.69 | s27-t211-sut1
361 10.30.51.70 | s55-t13-sut1
362 10.30.51.71 | s56-t14-sut1
363 10.30.51.72 | s62-t34-sut1
364 10.30.51.73 | s63-t34-sut2
365 10.30.51.74 | s64-t34-tg1
366 10.30.51.75-10.30.51.254 | FREE
367 10.30.51.255 | Broadcast
370 10.32.8.10 | s28-t26t35-tg1
371 10.32.8.11 | s29-t26-sut1
372 10.32.8.12 | s30-t35-sut1
373 10.32.8.13 | s31-t35-sut2
374 10.32.8.14 | s46-nomad
375 10.32.8.15 | s47-nomad
376 10.32.8.16 | s48-nomad
377 10.32.8.17 | s57-nomad
378 10.32.8.18 | s33-t27-sut1
379 10.32.8.19 | s34-t27-tg1
380 10.32.8.20 | s35-t28-sut1
381 10.32.8.21 | s36-t28-tg1
382 10.32.8.22 | s37-t29-sut1
383 10.32.8.23 | s38-t29-tg1
384 10.32.8.24 | s60-t210-sut1
385 10.32.8.25 | s61-t210-tg1
386 10.32.8.255 | Broadcast
388 ## Server Specifications
392 FD.io CSIT lab contains following server types:
394 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
395 - Quantity: 6 servers.
396 - Physical connectivity:
397 - CIMC and host management ports.
398 - NIC ports connected in 3-node topologies.
399 - Main HW configuration:
400 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
401 - Processors: 2* E5-2699v3 2.3 GHz.
402 - RAM Memory: 16* 32GB DDR4-2133MHz.
403 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
404 - NICs configuration:
405 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
409 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
413 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
414 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
415 - Quantity: 3 servers.
416 - Physical connectivity:
417 - CIMC and host management ports.
418 - NIC ports connected in 3-node topologies.
419 - Main HW configuration:
420 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
421 - Processors: 2* E5-2699v3 2.3 GHz.
422 - RAM Memory: 16* 32GB DDR4-2133MHz.
423 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
424 - NICs configuration:
425 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
429 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
434 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
435 - Quantity: 3 servers.
436 - Physical connectivity:
437 - CIMC and host management ports.
438 - no NIC ports, standalone setup.
439 - Main HW configuration:
440 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
441 - Processors: 2* E5-2699v3 2.3 GHz.
442 - RAM Memory: 16* 32GB DDR4-2133MHz.
443 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
444 - NICs configuration:
445 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
447 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
450 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
452 - Physical connectivity:
453 - IPMI and host management ports.
454 - NIC ports connected into 2-node and 3-node topologies.
455 - Main HW configuration:
456 - Chassis: SuperMicro SYS-7049GP-TRT.
457 - Motherboard: SuperMicro X11DPG-QT.
458 - Processors: 2* Intel Platinum 8180 2.5 GHz.
459 - RAM Memory: 16* 16GB DDR4-2666MHz.
460 - Disks: 2* 1.6TB 6G SATA SSD.
461 - NICs configuration:
462 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
463 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
464 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
465 - PCIe Slot9 5e:00.xx: empty.
466 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
467 - PCIe Slot6 86:00.xx: empty.
468 - PCIe Slot8 af:00.xx: empty.
469 - PCIe Slot10 d8:00.xx: empty.
470 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
472 - Physical connectivity:
473 - IPMI and host management ports.
474 - NIC ports connected into 2-node and 3-node topologies.
475 - Main HW configuration:
476 - Chassis: SuperMicro SYS-7049GP-TRT.
477 - Motherboard: SuperMicro X11DPG-QT.
478 - Processors: 2* Intel Platinum 8180 2.5 GHz.
479 - RAM Memory: 16* 16GB DDR4-2666MHz.
480 - Disks: 2* 1.6TB 6G SATA SSD.
481 - NICs configuration:
482 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
483 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
484 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
485 - PCIe Slot9 5e:00.xx: empty.
486 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
487 - PCIe Slot6 86:00.xx: empty.
488 - PCIe Slot8 af:00.xx: empty.
489 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
490 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
491 - Quantity: TBD based on testbed allocation.
492 - Physical connectivity:
493 - Management: serial Port (usb) for console
494 - NIC ports connected into 2-node.
495 - Main HW configuration:
496 - Chassis: Netgate XG-2758-1u
497 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
498 - RAM Memory: 16GB ECC
500 - NICs configuration:
501 - 2x 10Gb Intel 82599ES
503 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
505 - Physical connectivity:
506 - IPMI and host management ports.
507 - NIC ports connected into 1-node topologies.
508 - Main HW configuration:
509 - Chassis: SuperMicro SYS-7049GP-TRT.
510 - Motherboard: SuperMicro X11DPG-QT.
511 - Processors: 2* Intel Platinum 8180 2.5 GHz.
512 - RAM Memory: 16* 16GB DDR4-2666MHz.
513 - Disks: 2* 1.6TB 6G SATA SSD.
514 - NICs configuration:
515 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
516 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
517 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
518 - PCIe Slot9 5e:00.xx: empty.
519 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
520 - PCIe Slot6 86:00.xx: empty.
521 - PCIe Slot8 af:00.xx: empty.
522 - PCIe Slot10 d8:00.xx: empty.
523 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
525 - Physical connectivity:
526 - Host management interface: 10/100/1000-BaseT.
527 - 8-port 10GE SFP+ integrated NIC.
528 - Main HW configuration:
529 - Chassis: PS10GE4NG.
530 - Motherboard: SuperMicro X11DPG-QT.
531 - Processors: Quad-Core, Intel Processor.
532 - HW accelerators: FPGA offload.
534 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
535 - Physical Interfaces: 4 * 10GE SFP+.
536 - Operating System: Native IxOS.
537 - Interface configuration:
542 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
544 - Physical connectivity:
545 - IPMI and host management ports.
547 - Main HW configuration:
548 - Chassis: SuperMicro SYS-7049GP-TRT.
549 - Motherboard: SuperMicro X11DPG-QT.
550 - Processors: 2* Intel Platinum 8180 2.5 GHz.
551 - RAM Memory: 16* 16GB DDR4-2666MHz.
552 - Disks: 2* 1.6TB 6G SATA SSD.
553 - NICs configuration:
554 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
555 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
556 - PCIe Slot4 3b:00.xx: empty.
557 - PCIe Slot9 5e:00.xx: empty.
558 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
559 - PCIe Slot6 86:00.xx: empty.
560 - PCIe Slot8 af:00.xx: empty.
561 - PCIe Slot10 d8:00.xx: empty.
562 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
564 - Physical connectivity:
565 - IPMI and host management ports.
567 - Main HW configuration:
568 - Chassis: SuperMicro SYS-E300-9A
569 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
570 - RAM Memory: 32GB ECC
572 - NICs configuration:
573 - 2x 10Gb Intel x553 fiber ports
574 - 2x 10Gb Intel x553 copper ports
575 - 4x 1GB Intel I350 ports
576 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
578 - Physical connectivity:
579 - IPMI and host management ports.
580 - NIC ports connected into 1-node testbed topologies.
581 - Main HW configuration:
582 - Chassis: SuperMicro SYS-7049GP-TRT.
583 - Motherboard: SuperMicro X11DPG-QT.
584 - Processors: 2* Intel Platinum 8280 2.7 GHz.
585 - RAM Memory: 12* 16GB DDR4-2933.
586 - Disks: 2* 1.92TB SATA SSD.
587 - NICs configuration:
588 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
589 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
590 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
591 - PCIe Slot9 5e:00.xx: empty.
592 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
593 - PCIe Slot6 86:00.xx: empty.
594 - PCIe Slot8 af:00.xx: empty.
595 - PCIe Slot10 d8:00.xx: empty.
596 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
598 - Physical connectivity:
599 - IPMI and host management ports.
600 - NIC ports connected into 2-node testbed topologies.
601 - Main HW configuration:
602 - Chassis: SuperMicro SYS-7049GP-TRT.
603 - Motherboard: SuperMicro X11DPG-QT.
604 - Processors: 2* Intel Gold 6252N 2.3 GHz.
605 - RAM Memory: 12* 16GB DDR4-2933.
606 - Disks: 2* 1.92TB SATA SSD.
607 - NICs configuration:
608 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
609 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
610 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
611 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
612 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
613 - PCIe Slot6 86:00.xx: empty.
614 - PCIe Slot8 af:00.xx: empty.
615 - PCIe Slot10 d8:00.xx: empty.
616 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
618 - Physical connectivity:
619 - IPMI and host management ports.
620 - NIC ports connected into 2-node testbed topologies.
621 - Main HW configuration:
622 - Chassis: SuperMicro SYS-7049GP-TRT.
623 - Motherboard: SuperMicro X11DPG-QT.
624 - Processors: 2* Intel Platinum 8280 2.7 GHz.
625 - RAM Memory: 12* 16GB DDR4-2933.
626 - Disks: 2* 1.92TB SATA SSD.
627 - NICs configuration:
628 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
629 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
630 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
631 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
632 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
633 - PCIe Slot6 86:00.xx: empty.
634 - PCIe Slot8 af:00.xx: empty.
635 - PCIe Slot10 d8:00.xx: empty.
636 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
638 - Physical connectivity:
639 - CIMC and host management ports.
640 - no NIC ports, standalone setup.
641 - Main HW configuration:
642 - Chassis: SuperMicro 1029P-WTRT.
643 - Motherboard: SuperMicro X11DDW-NT.
644 - Processors: 2* Intel Platinum 8280 2.7 GHz.
645 - RAM Memory: 12* 16GB DDR4-2933.
646 - Disks: 4* 1.92TB SATA SSD.
647 - NICs configuration:
652 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
654 - Physical connectivity:
655 - IPMI and host management ports.
656 - NIC ports connected into 2-node testbed topologies.
657 - Main HW configuration:
658 - Chassis: SuperMicro AS-1114S-WTRT
659 - Processors: 1* AMD EPYC 7532 2.4 GHz.
660 - RAM Memory: 8* 32GB DDR4-2933.
661 - Disks: 1* 1TB SATA SSD.
662 - NICs configuration:
663 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
664 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
665 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
666 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
667 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
669 - Physical connectivity:
670 - IPMI and host management ports.
671 - NIC ports connected into 2-node testbed topologies.
672 - Main HW configuration:
673 - Chassis: SuperMicro AS-1114S-WTRT
674 - Processors: 1* AMD EPYC 7532 2.4 GHz.
675 - RAM Memory: 8* 32GB DDR4-2933.
676 - Disks: 1* 1TB SATA SSD.
677 - NICs configuration:
678 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
679 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
680 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
681 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
682 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
684 - Physical connectivity:
685 - IPMI and host management ports.
686 - NIC ports connected into 1-node topologies.
687 - Main HW configuration:
688 - Chassis: GIGABYTE Rack Mount
689 - Motherboard: MT91-FS4-00
690 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
691 - RAM Memory: 16 * 16GB DIMM
692 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
693 - NICs configuration:
695 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
696 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
698 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
699 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
700 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
702 - Physical connectivity:
703 - IPMI(?) and host management ports.
704 - NIC ports connected into 3-node topology.
705 - Main HW configuration:
706 - Chassis: Huawei TaiShan 2280.
707 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
708 - RAM Memory: 8* 16GB DDR4-2400MT/s
709 - Disks: 1* 4TB SATA HDD
710 - NICs configuration:
711 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
712 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
713 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
715 - Physical connectivity:
716 - IPMI and host management ports.
717 - NIC ports connected into 2-node topologies.
718 - Main HW configuration:
719 - Chassis: Gigabyte R181-T90 1U
720 - Motherboard: MT91-FS1
721 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
722 - RAM Memory: 4* 32GB RDIMM
723 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
724 - NICs configuration:
726 - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
728 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
729 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
731 - Physical connectivity:
732 - IPMI and host management ports.
733 - NIC ports connected into 3-node topologies.
734 - Main HW configuration:
740 - NICs configuration:
742 - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
743 - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
745 - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
746 - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
747 21. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
749 - Physical connectivity:
750 - IPMI and host management ports.
751 - NIC ports connected into 2-node and 3-node topologies.
752 - Main HW configuration:
753 - Chassis: SuperMicro SYS-7049GP-TRT.
754 - Motherboard: SuperMicro X11DPG-QT.
755 - Processors: 2* Intel Platinum 8180 2.5 GHz.
756 - RAM Memory: 16* 16GB DDR4-2666MHz.
757 - Disks: 2* 1.6TB 6G SATA SSD.
758 - NICs configuration:
759 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
760 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
761 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
762 - PCIe Slot9 5e:00.xx: empty.
763 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
764 - PCIe Slot6 86:00.xx: empty.
765 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
766 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
769 ### Naming Convention
771 Following naming convention is used within this page to specify physical
772 connectivity and wiring across defined CSIT testbeds:
775 - testbedname: testbedN.
777 - traffic-generator: tN-tgW.
778 - system-under-testX: tN-sutX.
783 - N - testbed number.
784 - tgW - server acts as traffic-generator with W index.
785 - sutX - server acts as system-under-test with X index.
786 - Y - PCIe slot number denoting a NIC card number within the host.
787 - Z - port number on the NIC card.
790 ## Testbeds Configuration
792 ### Per Testbed Server Allocation and Naming
794 #### 1-Node-Skylake Servers (1n-skx) PROD
797 - SUT [Server-Type-B6]:
798 - testbedname: testbed11.
799 - hostname: s1-t11-sut1.
800 - IPMI IP: 10.30.50.47
801 - Host IP: 10.30.51.50
803 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
804 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
805 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
806 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
807 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
808 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
809 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
810 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
811 - SUT [Server-Type-B6]:
812 - testbedname: testbed12.
813 - hostname: s2-t12-sut1.
814 - IPMI IP: 10.30.50.48
815 - Host IP: 10.30.51.51
817 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
818 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
819 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
820 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
821 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
822 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
823 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
824 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
827 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
830 - SUT [Server-Type-E11]:
831 - testbedname: testbed13
832 - hostname: s55-t13-sut1
833 - IPMI IP: 10.30.50.70
834 - Host IP: 10.30.51.70
836 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
837 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
838 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
839 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
840 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
841 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
842 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
843 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
844 - SUT [Server-Type-E11]:
845 - testbedname: testbed14
846 - hostname: s56-t14-sut1
847 - IPMI IP: 10.30.50.71
848 - Host IP: 10.30.51.71
850 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
851 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
852 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
853 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
854 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
855 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
856 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
857 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
860 #### 1-Node-Cascadelake Servers (1n-clx) PROD
863 - SUT [Server-Type-C1]:
864 - testbedname: testbed11.
865 - hostname: s32-t14-sut1.
866 - IPMI IP: 10.30.55.17
867 - Host IP: 10.32.8.17
869 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
870 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
871 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
872 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
873 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
874 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
875 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
876 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
879 #### 2-Node-Skylake Servers (2n-skx) PROD
882 - SUT [Server-Type-B1]:
883 - testbedname: testbed21.
884 - hostname: s3-t21-sut1.
885 - IPMI IP: 10.30.50.41
886 - Host IP: 10.30.51.44
888 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
889 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
890 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
891 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
892 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
893 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
894 - TG [Server-Type-B2]:
895 - testbedname: testbed21.
896 - hostname: s4-t21-tg1.
897 - IPMI IP: 10.30.50.42
898 - Host IP: 10.30.51.45
900 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
901 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
902 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
903 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
904 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
905 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
906 - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
907 - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
908 - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
909 - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
910 - SUT [Server-Type-B1]:
911 - testbedname: testbed22.
912 - hostname: s5-t22-sut1.
913 - IPMI IP: 10.30.50.49
914 - Host IP: 10.30.51.52
916 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
917 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
918 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
919 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
920 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
921 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
922 - TG [Server-Type-B2]:
923 - testbedname: testbed22.
924 - hostname: s6-t22-tg1.
925 - IPMI IP: 10.30.50.50
926 - Host IP: 10.30.51.53
928 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
929 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
930 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
931 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
932 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
933 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934 - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
935 - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
936 - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
937 - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
938 - SUT [Server-Type-B1]:
939 - testbedname: testbed23.
940 - hostname: s7-t23-sut1.
941 - IPMI IP: 10.30.50.51
942 - Host IP: 10.30.51.54
944 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
945 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
946 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
947 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
948 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
949 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
950 - TG [Server-Type-B2]:
951 - testbedname: testbed23.
952 - hostname: s8-t23-tg1.
953 - IPMI IP: 10.30.50.52
954 - Host IP: 10.30.51.55
956 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
957 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
958 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
959 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
960 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
961 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
962 - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
963 - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
964 - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
965 - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
966 - SUT [Server-Type-B1]:
967 - testbedname: testbed24.
968 - hostname: s9-t24-sut1.
969 - IPMI IP: 10.30.50.53
970 - Host IP: 10.30.51.56
972 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
973 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
974 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
975 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
976 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
977 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
978 - TG [Server-Type-B2]:
979 - testbedname: testbed24.
980 - hostname: s10-t24-tg1.
981 - IPMI IP: 10.30.50.54
982 - Host IP: 10.30.51.57
984 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
985 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
986 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
987 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
988 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
989 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
990 - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
991 - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
992 - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
993 - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
996 #### 2-Node-Denverton Servers (2n-dnv) PROD
998 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1001 - TG [Server-Type-B2]:
1002 - testbednames: testbed26 and testbed35.
1003 - hostname: s28-t26t35-tg1.
1004 - IPMI IP: 10.30.55.10
1005 - Host IP: 10.32.8.10
1007 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1008 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1009 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1010 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1011 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1012 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1013 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1014 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1015 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1016 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1017 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1018 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1019 - SUT [Server-Type-B10]:
1020 - testbednames: testbed26.
1021 - hostname: s29-t26-sut1.
1022 - IPMI IP: 10.30.55.11
1023 - Host IP: 10.32.8.11
1025 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1026 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1027 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1028 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1031 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1034 - SUT [Server-Type-B8]:
1035 - testbedname: testbed25.
1036 - hostname: s25-t25-sut1.
1037 - IPMI IP: 10.30.50.58
1038 - Host IP: 10.30.51.61
1040 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1041 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1042 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1043 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1044 - TG [Server-Type-B7]:
1045 - testbedname: testbed25.
1046 - hostname: s26-t25-tg1.
1047 - IPMI IP: 10.30.50.59
1048 - Host IP: 10.30.51.62
1050 - s26-t25-tg1-p1 - 10GE-port1.
1051 - s26-t25-tg1-p2 - 10GE-port2.
1052 - s26-t25-tg1-p3 - 10GE-port3.
1053 - s26-t25-tg1-p4 - 10GE-port4.
1056 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1059 - SUT [Server-Type-C2]:
1060 - testbedname: testbed27.
1061 - hostname: s33-t27-sut1.
1062 - IPMI IP: 10.30.55.18
1063 - Host IP: 10.32.8.18
1065 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1066 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1067 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1068 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1069 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1070 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1071 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1072 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1073 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1074 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1075 - TG [Server-Type-C3]:
1076 - testbedname: testbed27.
1077 - hostname: s34-t27-tg1.
1078 - IPMI IP: 10.30.55.19
1079 - Host IP: 10.32.8.19
1081 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1082 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1083 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1084 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1085 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1086 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1087 - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1088 - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1089 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1090 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1091 - SUT [Server-Type-C2]:
1092 - testbedname: testbed28.
1093 - hostname: s35-t28-sut1.
1094 - IPMI IP: 10.30.55.20
1095 - Host IP: 10.32.8.20
1097 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1098 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1099 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1100 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1101 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1102 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1103 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1104 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1105 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1106 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1107 - TG [Server-Type-C3]:
1108 - testbedname: testbed28.
1109 - hostname: s36-t28-tg1.
1110 - IPMI IP: 10.30.55.21
1111 - Host IP: 10.32.8.21
1113 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1114 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1115 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1116 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1117 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1118 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1119 - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1120 - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1121 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1122 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1123 - SUT [Server-Type-C2]:
1124 - testbedname: testbed29.
1125 - hostname: s37-t29-sut1.
1126 - IPMI IP: 10.30.55.22
1127 - Host IP: 10.32.8.22
1129 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1130 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1131 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1132 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1133 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1134 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1135 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1136 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1137 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1138 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1139 - TG [Server-Type-C3]:
1140 - testbedname: testbed29.
1141 - hostname: s38-t29-tg1.
1142 - IPMI IP: 10.30.55.23
1143 - Host IP: 10.32.8.23
1145 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1146 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1147 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1148 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1149 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1150 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1151 - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1152 - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1153 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1154 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1157 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1160 - SUT [Server-Type-D1]:
1161 - testbedname: testbed210.
1162 - hostname: s60-t210-sut1.
1163 - IPMI IP: 10.30.55.24
1164 - Host IP: 10.32.8.24
1166 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1167 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1168 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1169 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1170 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1171 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1172 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1173 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1174 - TG [Server-Type-D2]:
1175 - testbedname: testbed210.
1176 - hostname: s61-t210-tg1.
1177 - IPMI IP: 10.30.55.25
1178 - Host IP: 10.32.8.25
1180 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1181 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1182 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1183 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1184 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1185 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1186 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1187 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1190 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1192 Note: Server19 (TG) is shared between testbed33 & testbed211
1195 - SUT [Server-Type-E22]:
1196 - testbedname: testbed211.
1197 - hostname: s27-t211-sut1.
1198 - IPMI IP: 10.30.50.69
1199 - Host IP: 10.30.51.69
1201 - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1202 - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1203 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1204 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1205 - TG [Server-Type-E31]:
1206 - testbedname: testbed33 and testbed211.
1207 - hostname: s19-t33t211-tg1.
1208 - IPMI IP: 10.30.50.46
1209 - Host IP: 10.30.51.49
1211 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1212 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1213 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1214 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1215 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1216 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1217 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1218 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1219 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1220 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1221 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1222 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1225 #### 3-Node-Skylake Servers (3n-skx) PROD
1228 - ServerB11 [Server-Type-B1]:
1229 - testbedname: testbed31.
1230 - hostname: s11-t31-sut1.
1231 - IPMI IP: 10.30.50.43
1232 - Host IP: 10.30.51.46
1234 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1235 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1236 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1237 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1238 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1239 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1240 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1241 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1242 - ServerB12 [Server-Type-B1]:
1243 - testbedname: testbed31.
1244 - hostname: s12-t31-sut2.
1245 - IPMI IP: 10.30.50.44
1246 - Host IP: 10.30.51.47
1248 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1249 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1250 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1251 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1252 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1253 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1254 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1255 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1256 - ServerB13 [Server-Type-B2]:
1257 - testbedname: testbed31.
1258 - hostname: s13-t31-tg1.
1259 - IPMI IP: 10.30.50.45
1260 - Host IP: 10.30.51.48
1262 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1263 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1264 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1265 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1266 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1267 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1268 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1269 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1270 - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1271 - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1272 - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1273 - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1274 - ServerB14 [Server-Type-B1]:
1275 - testbedname: testbed32.
1276 - hostname: s14-t32-sut1.
1277 - IPMI IP: 10.30.50.55
1278 - Host IP: 10.30.51.58
1280 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1281 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1282 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1283 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1284 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1285 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1286 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1287 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1288 - ServerB15 [Server-Type-B1]:
1289 - testbedname: testbed32.
1290 - hostname: s15-t32-sut2.
1291 - IPMI IP: 10.30.50.56
1292 - Host IP: 10.30.51.59
1294 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1295 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1296 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1297 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1298 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1299 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1300 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1301 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1302 - ServerB16 [Server-Type-B2]:
1303 - testbedname: testbed32.
1304 - hostname: s16-t32-tg1.
1305 - IPMI IP: 10.30.50.57
1306 - Host IP: 10.30.51.60
1308 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1309 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1310 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1311 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1312 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1313 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1314 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1315 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1316 - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1317 - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1318 - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1319 - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1322 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1324 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1327 - ServerB22 [Server-Type-B5]:
1328 - testbedname: testbed35.
1329 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1330 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1331 - Host IP: 10.30.51.9
1333 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1334 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1336 - ServerB23 [Server-Type-B5]:
1337 - testbedname: testbed35.
1338 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1339 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1340 - Host IP: 10.30.51.10
1342 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1343 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1345 - ServerB24 [Server-Type-B5]:
1346 - testbedname: testbed35.
1347 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1348 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1349 - Host IP: 10.30.51.11
1351 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1352 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1356 #### 3-Node-Taishan Servers (3n-tsh) PROD
1358 Note: Server19 (TG) is shared between testbed33 & testbed211
1361 - SUT [Server-Type-E21]:
1362 - testbedname: testbed33.
1363 - hostname: s17-t33-sut1.
1364 - IPMI IP: 10.30.50.36
1365 - Host IP: 10.30.51.36
1367 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1368 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1369 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1370 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1371 - SUT [Server-Type-E21]:
1372 - testbedname: testbed33.
1373 - hostname: s18-t33-sut2.
1374 - IPMI IP: 10.30.50.37
1375 - Host IP: 10.30.51.37
1377 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1378 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1379 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1380 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1381 - TG [Server-Type-E31]:
1382 - testbedname: testbed33 and testbed211.
1383 - hostname: s19-t33t211-tg1.
1384 - IPMI IP: 10.30.50.46
1385 - Host IP: 10.30.51.49
1387 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1388 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1389 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1390 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1391 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1392 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1393 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1394 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1395 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1396 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1397 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1398 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1401 #### 3-Node-Altra Servers (3n-alt) TBD
1404 - SUT [Server-Type-E23]:
1405 - testbedname: testbed34.
1406 - hostname: s62-t34-sut1.
1407 - IPMI IP: 10.30.50.72
1408 - Host IP: 10.30.51.72
1410 - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1411 - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1412 - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1413 - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1414 - SUT [Server-Type-E23]:
1415 - testbedname: testbed34.
1416 - hostname: s63-t34-sut2.
1417 - IPMI IP: 10.30.50.73
1418 - Host IP: 10.30.51.73
1420 - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1421 - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1422 - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1423 - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1424 - TG [TBD Server-Type]:
1425 - testbedname: testbed34.
1426 - hostname: s64-t34-tg1.
1427 - IPMI IP: 10.30.50.74
1428 - Host IP: 10.30.51.74
1430 - s64-t34-tg1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1431 - s64-t34-tg1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1432 - s64-t34-tg1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1433 - s64-t34-tg1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1436 #### 3-Node-Denverton Servers (3n-dnv) PROD
1439 - ServerB30 [Server-Type-B10]:
1440 - testbednames: testbed35.
1441 - hostname: s30-t35-sut1.
1442 - IPMI IP: 10.30.55.12
1443 - Host IP: 10.32.8.12
1445 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1446 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1447 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1448 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1449 - ServerB31 [Server-Type-B10]:
1450 - testbednames: testbed35.
1451 - hostname: s31-t35-sut2.
1452 - IPMI IP: 10.30.55.13
1453 - Host IP: 10.32.8.13
1455 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1456 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1457 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1458 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1461 ### Per Testbed Wiring
1463 #### 1-Node-Skylake Wiring (1n-skx) PROD
1467 - ring1 10GE-ports x710-4p10GE:
1468 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1469 - ring2 10GE-ports x710-4p10GE:
1470 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1471 - ring3 10GE-ports x710-4p10GE:
1472 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1473 - ring4 10GE-ports x710-4p10GE:
1474 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1475 - ring5 100GE-ports e810-2p100GE:
1476 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1477 - ring6 100GE-ports e810-2p100GE:
1478 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1480 - ring1 10GE-ports x710-4p10GE:
1481 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1482 - ring2 10GE-ports x710-4p10GE:
1483 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1484 - ring3 10GE-ports x710-4p10GE:
1485 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1486 - ring4 10GE-ports x710-4p10GE:
1487 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1488 - ring5 100GE-ports e810-2p100GE:
1489 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1490 - ring6 100GE-ports e810-2p100GE:
1491 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1494 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1498 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1499 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1500 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1501 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1502 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1503 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1504 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1505 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1508 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1509 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1510 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1511 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1512 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1513 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1514 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1515 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1518 #### 2-Node-Skylake Wiring (2n-skx) PROD
1522 - ring1 10GE-ports x710-4p10GE on SUT:
1523 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1524 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1525 - ring2 10GE-ports x710-4p10GE on SUT:
1526 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1527 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1528 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1529 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1530 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1531 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1532 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1533 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1535 - ring1 10GE-ports x710-4p10GE on SUT:
1536 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1537 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1538 - ring2 10GE-ports x710-4p10GE on SUT:
1539 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1540 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1541 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1542 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1543 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1544 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1545 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1546 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1548 - ring1 10GE-ports x710-4p10GE on SUT:
1549 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1550 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1551 - ring2 10GE-ports x710-4p10GE on SUT:
1552 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1553 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1554 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1555 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1556 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1557 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1558 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1559 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1561 - ring1 10GE-ports x710-4p10GE on SUT:
1562 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1563 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1564 - ring2 10GE-ports x710-4p10GE on SUT:
1565 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1566 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1567 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1568 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1569 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1570 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1571 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1572 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1575 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1579 - ring1 10GE-ports x553 copper port on SUT:
1580 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1581 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1582 - ring2 10GE-ports x553 fiber port on SUT:
1583 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1584 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1587 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1591 - link1 10GE-port x710-4p10GE on SUT:
1592 - t25-tg1-p1 to t25-sut1-c2/p1.
1593 - link2 10GE-port x710-4p10GE on SUT:
1594 - t25-tg1-p2 to t25-sut1-c2/p2.
1595 - link3 10GE-port x710-4p10GE on SUT:
1596 - t25-tg1-p3 to t25-sut1-c2/p3.
1597 - link4 10GE-port x710-4p10GE on SUT:
1598 - t25-tg1-p4 to t25-sut1-c2/p4.
1601 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1605 - ring1 10GE-ports x710-4p10GE on SUT:
1606 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1607 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1608 - ring2 10GE-ports x710-4p10GE on SUT:
1609 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1610 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1611 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1612 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1613 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1614 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1615 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1616 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1617 - ring5 100GE-ports e810-2p100GE on SUT:
1618 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1619 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1621 - ring1 10GE-ports x710-4p10GE on SUT:
1622 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1623 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1624 - ring2 10GE-ports x710-4p10GE on SUT:
1625 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1626 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1627 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1628 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1629 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1630 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1631 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1632 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1633 - ring5 100GE-ports e810-2p100GE on SUT:
1634 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1635 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1637 - ring1 10GE-ports x710-4p10GE on SUT:
1638 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1639 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1640 - ring2 10GE-ports x710-4p10GE on SUT:
1641 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1642 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1643 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1644 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1645 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1646 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1647 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1648 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1649 - ring6 100GE-ports e810-2p100GE on SUT:
1650 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1651 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1654 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1658 - ring1 10GE-ports x710-4p10GE on SUT:
1659 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1660 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1661 - ring2 10GE-ports x710-4p10GE on SUT:
1662 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1663 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1664 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1665 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1666 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1667 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1668 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1669 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1672 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1676 - ring1 10GE-ports x520-2p10GE on SUTs:
1677 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1678 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1681 #### 3-Node-Skylake Wiring (3n-skx) PROD
1685 - ring1 10GE-ports x710-4p10GE on SUTs:
1686 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1687 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1688 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1689 - ring2 10GE-ports x710-4p10GE on SUT:
1690 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1691 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1692 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1693 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1694 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1695 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1696 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1697 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1698 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1699 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1700 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1701 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1702 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1703 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1705 - ring1 10GE-ports x710-4p10GE on SUTs:
1706 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1707 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1708 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1709 - ring2 10GE-ports x710-4p10GE on SUT:
1710 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1711 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1712 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1713 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1714 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1715 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1716 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1717 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1718 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1719 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1720 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1721 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1722 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1723 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1726 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1732 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1736 - ring1 10GE-ports x520-2p10GE on SUTs:
1737 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1738 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1739 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1740 - ring2 25GE-ports cx4-2p25GE on SUTs:
1741 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1742 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1743 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1746 #### 3-Node-Altra Wiring (3n-alt) TBD
1750 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1751 - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
1752 - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
1753 - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
1754 - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
1755 - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
1756 - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
1757 - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
1760 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1764 - ring1 10GE-ports x553 copper port on SUTs:
1765 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1766 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1767 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1768 - ring2 10GE-ports x553 fiber port on SUTs:
1769 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1770 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1771 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1779 1. Ixia PerfectStorm One Appliance
1781 - Chassis: PS10GE4NG.
1782 - Motherboard: SuperMicro X11DPG-QT.
1783 - Processors: Quad-Core, Intel Processor.
1784 - HW accelerators: FPGA offload.
1786 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1787 - Physical Interfaces: 4 * 10GE SFP+.
1788 - Operating System: Native IxOS.
1794 1. Arm Cortex A-72 servers
1795 - 2 * ThunderX2 (VPP Device)
1796 - Chassis: GIGABYTE Rack Mount
1797 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1798 - RAM Memory: 16* 16GB DIMM
1799 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1800 - 1 * ThunderX2 (Performance)
1801 - Chassis: GIGABYTE Rack Mount
1802 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1803 - RAM Memory: 4* 32GB RDIMM
1804 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1805 - 2 * Huawei TaiShan 2280.
1806 - Chassis: Huawei TaiShan 2280.
1807 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1808 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1809 - Disks: 1* 4TB SATA HDD.
1817 ### Xeon and Atom Servers
1820 1. Intel Xeon servers:
1821 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1822 - Chassis: SuperMicro SYS-7049GP-TRT.
1823 - Motherboard: SuperMicro X11DPG-QT.
1824 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1825 - RAM Memory: 16* 16GB DDR4-2666MHz.
1826 - Disks: 2* 1.6TB 6G SATA SSD.
1827 2. Intel Atom servers with Rangely processors.
1828 - 3 * Netgate XG-2758-1u
1829 - Chassis: Netgate XG-2758-1u
1830 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1831 - RAM Memory: 16GB ECC
1835 ### Network Interface Cards
1839 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1840 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1841 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1843 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1845 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1847 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1850 ### Pluggables and Cables
1856 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1857 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1863 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1874 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable