1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
10 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
11 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
12 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
13 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
14 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
17 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
18 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
33 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
34 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
35 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
36 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
39 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
40 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
41 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
54 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
55 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr
75 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0
76 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0
77 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 2 0 0 0 0 0 0
78 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 0 0
79 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 2 0 0 0 0
80 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0
81 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 0 0 0 0 0 0 0
82 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0
83 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 0 0
84 10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 1 0 0 0 0 0 0
85 11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 8 0
86 12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0
87 13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0
88 14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 2 0 0 0 0 0
89 15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 2 0 0 1 0
90 17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2 0 0
91 18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 6 0
92 19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 .5 2
93 Totals: 32 41 20.5 4 17 1 2 3 2 4 7 2 15.5 2
96 ### 1-Node-Skylake Xeon Intel (1n-skx)
98 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
99 ports connected back-to-back ([Server Types](#server-types)).
100 Used for FD.io VPP_Device functional driver tests.
102 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
104 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
105 ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
110 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
111 NIC ports connected back-to-back ([Server Types](#server-types)).
113 Used for FD.io VPP_Device functional driver tests.
115 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
117 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
118 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
119 circular topology ([Server Types](#server-types)).
120 Used for FD.io TCP/IP and HTTP performance tests.
122 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
124 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
125 one TG (Server-Type-C3) connected in a 2-node circular topology
126 ([Server Types](#server-types)).
127 Used for FD.io performance tests.
129 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
131 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
132 one TG (Server-Type-D2) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
138 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
139 one TG (Server-Type-E31) connected in a 2-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 2-Node-Icelake Xeon Intel (2n-icx)
145 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
146 one TG (Server-Type-F2) connected in a 2-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
150 ### 3-Node-Haswell Xeon Intel (3n-hsw)
152 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
153 TG (Server-Type-A2) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
157 ### 3-Node-Rangeley Atom Testbeds
159 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
160 TG (Server-Type-2) connected in a 3-node circular topology
161 ([Server Types](#server-types)).
162 Used for FD.io performance tests.
164 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
166 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
167 TG (Server-Type-E31) connected in a 3-node circular topology
168 ([Server Types](#server-types)).
169 Used for FD.io performance tests.
171 ### 3-Node-Altra Arm Ampere (3n-alt)
173 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
174 TG (Server-Type-F4) connected in a 3-node circular topology
175 ([Server Types](#server-types)).
176 Used for FD.io performance tests.
178 ### 3-Node-Icelake Xeon Intel (3n-icx)
180 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
181 TG (Server-Type-F3) connected in a 3-node circular topology
182 ([Server Types](#server-types)).
183 Used for FD.io performance tests.
185 ### 3-Node-SnowRidge Atom Intel (3n-snr)
187 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
188 TG (Server-Type-F4) connected in a 3-node circular topology
189 ([Server Types](#server-types)).
190 Used for FD.io performance tests.
197 For management purposes, each server must have following two ports
198 connected to the management network:
202 - IPMI - Intelligent Platform Management Interface.
203 - Required for access to embedded server management with WebUI, CLI,
204 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
205 - 1GE/10GE/40GE management port
206 - hostOS management port for general system management.
211 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
212 Management port, which are connected to two different VLANs.
216 - Subnet: 10.30.50.0/24
217 - Gateway: 10.30.50.1
218 - Broadcast: 10.30.50.255
219 - DNS1: 199.204.44.24
220 - DNS2: 199.204.47.54
222 - Subnet: 10.30.51.0/24
223 - Gateway: 10.30.51.1
224 - Broadcast: 10.30.51.255
225 - DNS1: 199.204.44.24
226 - DNS2: 199.204.47.54
229 To access these hosts, VPN connection is required.
231 ### LOM (IPMI) VLAN IP Addresses
234 ------------ | -------
237 10.30.50.2 | LF Reserved
238 10.30.50.3 | LF Reserved
239 10.30.50.4 | LF Reserved
240 10.30.50.5 | LF Reserved
241 10.30.50.6 | LF Reserved
242 10.30.50.7 | LF Reserved
243 10.30.50.8 | LF Reserved
244 10.30.50.9 | LF Reserved
245 10.30.50.10 | LF Reserved
246 10.30.50.11 | LF Reserved
247 10.30.50.12 | LF Reserved
248 10.30.50.13 | LF Reserved
249 10.30.50.14 | LF Reserved
250 10.30.50.15 | LF Reserved
251 10.30.50.20 | s20-nomad
252 10.30.50.21 | s21-nomad
253 10.30.50.22 | s22-nomad
254 10.30.50.23 | s23-nomad
255 10.30.50.24 | s24-nomad
256 10.30.50.25 | s25-nomad
257 10.30.50.26 | s26-nomad
258 10.30.50.27 | s27-nomad
259 10.30.50.28 | s28-nomad
260 10.30.50.36 | s17-t33-sut1
261 10.30.50.37 | s18-t33-sut2
262 10.30.50.38 | fdio-marvell-dev
263 10.30.50.46 | s19-t33t211-tg1
264 10.30.50.47 | s1-t11-sut1
265 10.30.50.48 | s2-t12-sut1
266 10.30.50.58 | s25-t25-sut1
267 10.30.50.59 | s26-t25-tg1
268 10.30.50.69 | s27-t211-sut1
269 10.30.50.70 | s55-t13-sut1
270 10.30.50.71 | s56-t14-sut1
271 10.30.50.72 | s62-t34-sut1
272 10.30.50.73 | s63-t34-sut2
273 10.30.50.74 | s64-t34-tg1
274 10.30.50.75 | s65-t37-sut1
275 10.30.50.76 | s66-t37-sut2
276 10.30.50.77 | s67-t37-tg1
277 10.30.50.78 | s78-t38-sut1
278 10.30.50.79 | s79-t38-sut2
279 10.30.50.80 | s80-t38-tg1
280 10.30.50.81 | s71-t212-sut1
281 10.30.50.82 | s72-t212-tg1
282 10.30.50.83 | s83-t213-sut1
283 10.30.50.84 | s84-t213-tg1
284 10.30.50.85 | s85-t214-sut1
285 10.30.50.86 | s86-t214-tg1
286 10.30.50.87 | s87-t215-sut1
287 10.30.50.88 | s88-t215-tg1
288 10.30.50.89 | s89-t39t310-tg1
289 10.30.50.90 | s90-t311t312-tg1
290 10.30.50.91 | s91-nomad
291 10.30.50.92 | s92-nomad
292 10.30.50.93 | s93-t39-sut1
293 10.30.50.94 | s94-t39-sut2
294 10.30.50.255 | Broadcast
297 10.30.55.10 | s28-t26t35-tg1
298 10.30.55.11 | s29-t26-sut1
299 10.30.55.12 | s30-t35-sut1
300 10.30.55.13 | s31-t35-sut2
301 10.30.55.18 | s33-t27-sut1
302 10.30.55.19 | s34-t27-tg1
303 10.30.55.20 | s35-t28-sut1
304 10.30.55.21 | s36-t28-tg1
305 10.30.55.22 | s37-t29-sut1
306 10.30.55.23 | s38-t29-tg1
307 10.30.55.24 | s60-t210-sut1
308 10.30.55.25 | s61-t210-tg1
309 10.30.55.255 | Broadcast
311 ### Management VLAN IP Addresses
314 -------------| -------
317 10.30.51.2 | LF Reserved
318 10.30.51.3 | LF Reserved
319 10.30.51.4 | LF Reserved
320 10.30.51.5 | LF Reserved
321 10.30.51.6 | LF Reserved
322 10.30.51.7 | LF Reserved
323 10.30.51.8 | LF Reserved
324 10.30.51.15 | LF Reserved
325 10.30.51.20 | s20-nomad
326 10.30.51.21 | s21-nomad
327 10.30.51.22 | s22-nomad
328 10.30.51.23 | s23-nomad
329 10.30.51.24 | s24-nomad
330 10.30.51.25 | s25-nomad
331 10.30.51.26 | s26-nomad
332 10.30.51.27 | s27-nomad
333 10.30.51.28 | s28-nomad
334 10.30.51.36 | s17-t33-sut1
335 10.30.51.37 | s18-t33-sut2
336 10.30.51.38 | fdio-marvell-dev
337 10.30.51.49 | s19-t33t211-tg1
338 10.30.51.50 | s1-t11-sut1
339 10.30.51.51 | s2-t12-sut1
340 10.30.51.61 | s25-t25-sut1
341 10.30.51.62 | s26-t25-tg1
342 10.30.51.69 | s27-t211-sut1
343 10.30.51.70 | s55-t13-sut1
344 10.30.51.71 | s56-t14-sut1
345 10.30.51.72 | s62-t34-sut1
346 10.30.51.73 | s63-t34-sut2
347 10.30.51.74 | s64-t34-tg1
348 10.30.51.75 | s65-t37-sut1
349 10.30.51.76 | s66-t37-sut2
350 10.30.51.77 | s67-t37-tg1
351 10.30.51.78 | s78-t38-sut1
352 10.30.51.79 | s79-t38-sut2
353 10.30.51.80 | s80-t38-tg1
354 10.30.51.81 | s71-t212-sut1
355 10.30.51.82 | s72-t212-tg1
356 10.30.51.83 | s83-t213-sut1
357 10.30.51.84 | s84-t213-tg1
358 10.30.51.85 | s85-t214-sut1
359 10.30.51.86 | s86-t214-tg1
360 10.30.51.87 | s87-t215-sut1
361 10.30.51.88 | s88-t215-tg1
362 10.30.51.89 | s89-t39t310-tg1
363 10.30.51.90 | s90-t311t312-tg1
364 10.30.51.91 | s91-nomad
365 10.30.51.92 | s92-nomad
366 10.30.51.93 | s93-t39-sut1
367 10.30.51.94 | s94-t39-sut2
368 10.30.51.255 | Broadcast
371 10.32.8.18 | s33-t27-sut1
372 10.32.8.19 | s34-t27-tg1
373 10.32.8.20 | s35-t28-sut1
374 10.32.8.21 | s36-t28-tg1
375 10.32.8.22 | s37-t29-sut1
376 10.32.8.23 | s38-t29-tg1
377 10.32.8.24 | s60-t210-sut1
378 10.32.8.25 | s61-t210-tg1
379 10.32.8.255 | Broadcast
381 ## Server Specifications
385 FD.io CSIT lab contains following server types:
387 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
388 - Quantity: 6 servers.
389 - Physical connectivity:
390 - CIMC and host management ports.
391 - NIC ports connected in 3-node topologies.
392 - Main HW configuration:
393 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
394 - Processors: 2* E5-2699v3 2.3 GHz.
395 - RAM Memory: 16* 32GB DDR4-2133MHz.
396 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
397 - NICs configuration:
398 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
402 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
406 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
407 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
408 - Quantity: 3 servers.
409 - Physical connectivity:
410 - CIMC and host management ports.
411 - NIC ports connected in 3-node topologies.
412 - Main HW configuration:
413 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
414 - Processors: 2* E5-2699v3 2.3 GHz.
415 - RAM Memory: 16* 32GB DDR4-2133MHz.
416 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
417 - NICs configuration:
418 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
422 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
427 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
428 - Quantity: 3 servers.
429 - Physical connectivity:
430 - CIMC and host management ports.
431 - no NIC ports, standalone setup.
432 - Main HW configuration:
433 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
434 - Processors: 2* E5-2699v3 2.3 GHz.
435 - RAM Memory: 16* 32GB DDR4-2133MHz.
436 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
437 - NICs configuration:
438 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
440 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
443 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
445 - Physical connectivity:
446 - IPMI and host management ports.
447 - NIC ports connected into 2-node and 3-node topologies.
448 - Main HW configuration:
449 - Chassis: SuperMicro SYS-7049GP-TRT.
450 - Motherboard: SuperMicro X11DPG-QT.
451 - Processors: 2* Intel Platinum 8180 2.5 GHz.
452 - RAM Memory: 16* 16GB DDR4-2666MHz.
453 - Disks: 2* 1.6TB 6G SATA SSD.
454 - NICs configuration:
455 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
456 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
457 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
458 - PCIe Slot9 5e:00.xx: empty.
459 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
460 - PCIe Slot6 86:00.xx: empty.
461 - PCIe Slot8 af:00.xx: empty.
462 - PCIe Slot10 d8:00.xx: empty.
463 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
465 - Physical connectivity:
466 - IPMI and host management ports.
467 - NIC ports connected into 2-node and 3-node topologies.
468 - Main HW configuration:
469 - Chassis: SuperMicro SYS-7049GP-TRT.
470 - Motherboard: SuperMicro X11DPG-QT.
471 - Processors: 2* Intel Platinum 8180 2.5 GHz.
472 - RAM Memory: 16* 16GB DDR4-2666MHz.
473 - Disks: 2* 1.6TB 6G SATA SSD.
474 - NICs configuration:
475 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
476 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
477 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
478 - PCIe Slot9 5e:00.xx: empty.
479 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
480 - PCIe Slot6 86:00.xx: empty.
481 - PCIe Slot8 af:00.xx: empty.
482 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
483 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
484 - Quantity: TBD based on testbed allocation.
485 - Physical connectivity:
486 - Management: serial Port (usb) for console
487 - NIC ports connected into 2-node.
488 - Main HW configuration:
489 - Chassis: Netgate XG-2758-1u
490 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
491 - RAM Memory: 16GB ECC
493 - NICs configuration:
494 - 2x 10Gb Intel 82599ES
496 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
498 - Physical connectivity:
499 - IPMI and host management ports.
500 - NIC ports connected into 1-node topologies.
501 - Main HW configuration:
502 - Chassis: SuperMicro SYS-7049GP-TRT.
503 - Motherboard: SuperMicro X11DPG-QT.
504 - Processors: 2* Intel Platinum 8180 2.5 GHz.
505 - RAM Memory: 16* 16GB DDR4-2666MHz.
506 - Disks: 2* 1.6TB 6G SATA SSD.
507 - NICs configuration:
508 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
509 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
510 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
511 - PCIe Slot9 5e:00.xx: empty.
512 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
513 - PCIe Slot6 86:00.xx: empty.
514 - PCIe Slot8 af:00.xx: empty.
515 - PCIe Slot10 d8:00.xx: empty.
516 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
518 - Physical connectivity:
519 - Host management interface: 10/100/1000-BaseT.
520 - 8-port 10GE SFP+ integrated NIC.
521 - Main HW configuration:
522 - Chassis: PS10GE4NG.
523 - Motherboard: SuperMicro X11DPG-QT.
524 - Processors: Quad-Core, Intel Processor.
525 - HW accelerators: FPGA offload.
527 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
528 - Physical Interfaces: 4 * 10GE SFP+.
529 - Operating System: Native IxOS.
530 - Interface configuration:
535 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
537 - Physical connectivity:
538 - IPMI and host management ports.
540 - Main HW configuration:
541 - Chassis: SuperMicro SYS-7049GP-TRT.
542 - Motherboard: SuperMicro X11DPG-QT.
543 - Processors: 2* Intel Platinum 8180 2.5 GHz.
544 - RAM Memory: 16* 16GB DDR4-2666MHz.
545 - Disks: 2* 1.6TB 6G SATA SSD.
546 - NICs configuration:
547 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
548 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
549 - PCIe Slot4 3b:00.xx: empty.
550 - PCIe Slot9 5e:00.xx: empty.
551 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
552 - PCIe Slot6 86:00.xx: empty.
553 - PCIe Slot8 af:00.xx: empty.
554 - PCIe Slot10 d8:00.xx: empty.
555 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
557 - Physical connectivity:
558 - IPMI and host management ports.
560 - Main HW configuration:
561 - Chassis: SuperMicro SYS-E300-9A
562 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
563 - RAM Memory: 32GB ECC
565 - NICs configuration:
566 - 2x 10Gb Intel x553 fiber ports
567 - 2x 10Gb Intel x553 copper ports
568 - 4x 1GB Intel I350 ports
569 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
571 - Physical connectivity:
572 - IPMI and host management ports.
573 - NIC ports connected into 1-node testbed topologies.
574 - Main HW configuration:
575 - Chassis: SuperMicro SYS-7049GP-TRT.
576 - Motherboard: SuperMicro X11DPG-QT.
577 - Processors: 2* Intel Platinum 8280 2.7 GHz.
578 - RAM Memory: 12* 16GB DDR4-2933.
579 - Disks: 2* 1.92TB SATA SSD.
580 - NICs configuration:
581 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
582 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
583 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
584 - PCIe Slot9 5e:00.xx: empty.
585 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
586 - PCIe Slot6 86:00.xx: empty.
587 - PCIe Slot8 af:00.xx: empty.
588 - PCIe Slot10 d8:00.xx: empty.
589 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
591 - Physical connectivity:
592 - IPMI and host management ports.
593 - NIC ports connected into 2-node testbed topologies.
594 - Main HW configuration:
595 - Chassis: SuperMicro SYS-7049GP-TRT.
596 - Motherboard: SuperMicro X11DPG-QT.
597 - Processors: 2* Intel Gold 6252N 2.3 GHz.
598 - RAM Memory: 12* 16GB DDR4-2933.
599 - Disks: 2* 1.92TB SATA SSD.
600 - NICs configuration:
601 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
602 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
603 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
604 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
605 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
606 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
607 - PCIe Slot8 af:00.xx: empty.
608 - PCIe Slot10 d8:00.xx: empty.
609 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
611 - Physical connectivity:
612 - IPMI and host management ports.
613 - NIC ports connected into 2-node testbed topologies.
614 - Main HW configuration:
615 - Chassis: SuperMicro SYS-7049GP-TRT.
616 - Motherboard: SuperMicro X11DPG-QT.
617 - Processors: 2* Intel Platinum 8280 2.7 GHz.
618 - RAM Memory: 12* 16GB DDR4-2933.
619 - Disks: 2* 1.92TB SATA SSD.
620 - NICs configuration:
621 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
622 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
623 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
624 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
625 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
626 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
627 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
628 - PCIe Slot10 d8:00.xx: empty.
629 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
631 - Physical connectivity:
632 - IPMI and host management ports.
633 - no NIC ports, standalone setup.
634 - Main HW configuration:
635 - Chassis: SuperMicro 1029P-WTRT.
636 - Motherboard: SuperMicro X11DDW-NT.
637 - Processors: 2* Intel Platinum 8280 2.7 GHz.
638 - RAM Memory: 12* 16GB DDR4-2933.
639 - Disks: 4* 1.92TB SATA SSD.
640 - NICs configuration:
645 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
647 - Physical connectivity:
648 - IPMI and host management ports.
649 - NIC ports connected into 2-node testbed topologies.
650 - Main HW configuration:
651 - Chassis: SuperMicro AS-1114S-WTRT
652 - Processors: 1* AMD EPYC 7532 2.4 GHz.
653 - RAM Memory: 8* 32GB DDR4-2933.
654 - Disks: 1* 1TB SATA SSD.
655 - NICs configuration:
656 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
657 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
658 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
659 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
660 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
662 - Physical connectivity:
663 - IPMI and host management ports.
664 - NIC ports connected into 2-node testbed topologies.
665 - Main HW configuration:
666 - Chassis: SuperMicro AS-1114S-WTRT
667 - Processors: 1* AMD EPYC 7532 2.4 GHz.
668 - RAM Memory: 8* 32GB DDR4-2933.
669 - Disks: 1* 1TB SATA SSD.
670 - NICs configuration:
671 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
672 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
673 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
674 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
675 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
677 - Physical connectivity:
678 - IPMI and host management ports.
679 - NIC ports connected into 1-node topologies.
680 - Main HW configuration:
681 - Chassis: GIGABYTE Rack Mount
682 - Motherboard: MT91-FS4-00
683 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
684 - RAM Memory: 16 * 16GB DIMM
685 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
686 - NICs configuration:
688 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
689 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
691 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
692 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
693 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
695 - Physical connectivity:
696 - IPMI(?) and host management ports.
697 - NIC ports connected into 3-node topology.
698 - Main HW configuration:
699 - Chassis: Huawei TaiShan 2280.
700 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
701 - RAM Memory: 8* 16GB DDR4-2400MT/s
702 - Disks: 1* 4TB SATA HDD
703 - NICs configuration:
704 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
705 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
706 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
708 - Physical connectivity:
709 - IPMI and host management ports.
710 - NIC ports connected into 2-node topologies.
711 - Main HW configuration:
712 - Chassis: Gigabyte R181-T90 1U
713 - Motherboard: MT91-FS1
714 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
715 - RAM Memory: 4* 32GB RDIMM
716 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
717 - NICs configuration:
721 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
722 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
724 - Physical connectivity:
725 - IPMI and host management ports.
726 - NIC ports connected into 3-node topologies.
727 - Main HW configuration:
728 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
729 - Motherboard: Mt.Jade Motherboard
730 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
731 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
732 - RAM Memory: 16* 8GB DDR4-3200MT/s
733 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
734 - NICs configuration:
736 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
739 21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
741 - Physical connectivity:
742 - IPMI and host management ports.
743 - Main HW configuration:
744 - Chassis: Gigabyte R152-P30-00 1U
745 - Motherboard: MP32-AR1-00
746 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
747 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
748 - RAM Memory: 12* 16GB DDR4-3200MT/s
749 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
750 22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
752 - Physical connectivity:
753 - IPMI and host management ports.
754 - NIC ports connected into 2-node and 3-node topologies.
755 - Main HW configuration:
756 - Chassis: SuperMicro SYS-7049GP-TRT.
757 - Motherboard: SuperMicro X11DPG-QT.
758 - Processors: 2* Intel Platinum 8180 2.5 GHz.
759 - RAM Memory: 16* 16GB DDR4-2666MHz.
760 - Disks: 2* 1.6TB 6G SATA SSD.
761 - NICs configuration:
762 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
763 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
764 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
765 - PCIe Slot9 5e:00.xx: empty.
766 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
767 - PCIe Slot6 86:00.xx: empty.
768 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
769 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
770 23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
772 - Physical connectivity:
773 - IPMI and host management ports.
774 - NIC ports connected into 2-node or 3-node testbed topologies.
775 - Main HW configuration:
776 - Chassis: SuperMicro SYS-740GP-TNRT.
777 - Motherboard: Super X12DPG-QT6.
778 - Processors: 2* Intel Platinum 8358 2.6 GHz.
779 - RAM Memory: 16* 16GB DDR4-3200.
780 - Disks: 2* 960GB SATA SSD.
781 - NICs configuration:
782 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
783 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
784 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
785 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
786 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
787 - PCIe Slot6 86:00.xx: empty.
788 - PCIe Slot8 af:00.xx: empty.
789 - PCIe Slot10 d8:00.xx: empty.
790 24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
792 - Physical connectivity:
793 - IPMI and host management ports.
794 - NIC ports connected into 2-node testbed topologies.
795 - Main HW configuration:
796 - Chassis: SuperMicro SYS-740GP-TNRT.
797 - Motherboard: Super X12DPG-QT6.
798 - Processors: 2* Intel Platinum 8358 2.6 GHz.
799 - RAM Memory: 16* 16GB DDR4-3200.
800 - Disks: 2* 960GB SATA SSD.
801 - NICs configuration:
802 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
803 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
804 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
805 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
806 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
807 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
808 - PCIe Slot8 af:00.xx: empty.
809 - PCIe Slot10 d8:00.xx: empty.
810 25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
812 - Physical connectivity:
813 - IPMI and host management ports.
814 - NIC ports connected into 3-node testbed topologies.
815 - Main HW configuration:
816 - Chassis: SuperMicro SYS-740GP-TNRT.
817 - Motherboard: Super X12DPG-QT6.
818 - Processors: 2* Intel Platinum 8358 2.6 GHz.
819 - RAM Memory: 16* 16GB DDR4-3200.
820 - Disks: 2* 960GB SATA SSD.
821 - NICs configuration:
822 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
823 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
824 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
825 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
826 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
827 - PCIe Slot6 86:00.xx: empty.
828 - PCIe Slot8 af:00.xx: empty.
829 - PCIe Slot10 d8:00.xx: empty.
830 26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
832 - Physical connectivity:
833 - IPMI and host management ports.
834 - NIC ports connected into 2-node and/or 3-node testbed topologies.
835 - Main HW configuration:
836 - Chassis: SuperMicro SYS-740GP-TNRT.
837 - Motherboard: Super X12DPG-QT6.
838 - Processors: 2* Intel Platinum 8358 2.6 GHz.
839 - RAM Memory: 16* 16GB DDR4-3200.
840 - Disks: 2* 960GB SATA SSD.
841 - NICs configuration:
842 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
843 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
844 - PCIe Slot4 3b:00.xx: empty.
845 - PCIe Slot9 5e:00.xx: empty.
846 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
847 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
848 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
849 - PCIe Slot10 d8:00.xx: empty.
850 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
852 - Physical connectivity:
853 - IPMI and host management ports.
854 - NIC ports connected into 3-node testbed topology.
855 - Main HW configuration:
856 - Chassis: Intel JACOBSVILLE SDP.
857 - Motherboard: Intel JACOBSVILLE E63448-400.
858 - Processors: 1* Intel Atom P5362B 2.2 GHz.
859 - RAM Memory: 2* 16GB DDR4-2933.
860 - Disks: ?* ? SATA SSD.
861 - NICs configuration:
862 - Numa0: (x16, PCIe3.0 lane)
863 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
866 ### Naming Convention
868 Following naming convention is used within this page to specify physical
869 connectivity and wiring across defined CSIT testbeds:
872 - testbedname: testbedN.
874 - traffic-generator: tN-tgW.
875 - system-under-testX: tN-sutX.
880 - N - testbed number.
881 - tgW - server acts as traffic-generator with W index.
882 - sutX - server acts as system-under-test with X index.
883 - Y - PCIe slot number denoting a NIC card number within the host.
884 - Z - port number on the NIC card.
887 ## Testbeds Configuration
889 ### Per Testbed Server Allocation and Naming
891 #### 1-Node-Skylake Servers (1n-skx) PROD
894 - SUT [Server-Type-B6]:
895 - testbedname: testbed11.
896 - hostname: s1-t11-sut1.
897 - IPMI IP: 10.30.50.47
898 - Host IP: 10.30.51.50
900 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
901 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
902 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
903 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
904 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
905 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
906 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
907 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
908 - SUT [Server-Type-B6]:
909 - testbedname: testbed12.
910 - hostname: s2-t12-sut1.
911 - IPMI IP: 10.30.50.48
912 - Host IP: 10.30.51.51
914 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
915 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
916 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
917 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
918 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
919 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
920 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
921 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
924 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
927 - SUT [Server-Type-E11]:
928 - testbedname: testbed13
929 - hostname: s55-t13-sut1
930 - IPMI IP: 10.30.50.70
931 - Host IP: 10.30.51.70
933 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
934 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
935 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
936 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
937 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
938 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
939 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
940 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
941 - SUT [Server-Type-E11]:
942 - testbedname: testbed14
943 - hostname: s56-t14-sut1
944 - IPMI IP: 10.30.50.71
945 - Host IP: 10.30.51.71
947 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
948 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
949 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
950 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
951 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
952 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
953 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
954 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
957 #### 1-Node-Cascadelake Servers (1n-clx) PROD
960 - SUT [Server-Type-C1]:
961 - testbedname: testbed11.
962 - hostname: s32-t14-sut1.
963 - IPMI IP: 10.30.55.17
964 - Host IP: 10.32.8.17
966 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
967 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
968 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
969 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
970 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
971 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
972 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
973 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
976 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
979 - SUT [Server-Type-B8]:
980 - testbedname: testbed25.
981 - hostname: s25-t25-sut1.
982 - IPMI IP: 10.30.50.58
983 - Host IP: 10.30.51.61
985 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
986 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
987 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
988 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
989 - TG [Server-Type-B7]:
990 - testbedname: testbed25.
991 - hostname: s26-t25-tg1.
992 - IPMI IP: 10.30.50.59
993 - Host IP: 10.30.51.62
995 - s26-t25-tg1-p1 - 10GE-port1.
996 - s26-t25-tg1-p2 - 10GE-port2.
997 - s26-t25-tg1-p3 - 10GE-port3.
998 - s26-t25-tg1-p4 - 10GE-port4.
1001 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1004 - SUT [Server-Type-C2]:
1005 - testbedname: testbed27.
1006 - hostname: s33-t27-sut1.
1007 - IPMI IP: 10.30.55.18
1008 - Host IP: 10.32.8.18
1010 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1011 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1012 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1013 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1014 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1015 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1016 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1017 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1018 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1019 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1020 - TG [Server-Type-C3]:
1021 - testbedname: testbed27.
1022 - hostname: s34-t27-tg1.
1023 - IPMI IP: 10.30.55.19
1024 - Host IP: 10.32.8.19
1026 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1027 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1028 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1029 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1030 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1031 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1032 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1033 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1034 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1035 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1036 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1037 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1038 - SUT [Server-Type-C2]:
1039 - testbedname: testbed28.
1040 - hostname: s35-t28-sut1.
1041 - IPMI IP: 10.30.55.20
1042 - Host IP: 10.32.8.20
1044 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1045 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1046 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1047 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1048 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1049 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1050 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1051 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1052 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1053 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1054 - TG [Server-Type-C3]:
1055 - testbedname: testbed28.
1056 - hostname: s36-t28-tg1.
1057 - IPMI IP: 10.30.55.21
1058 - Host IP: 10.32.8.21
1060 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1061 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1062 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1063 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1064 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1065 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1066 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1067 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1068 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1069 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1070 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1071 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1072 - SUT [Server-Type-C2]:
1073 - testbedname: testbed29.
1074 - hostname: s37-t29-sut1.
1075 - IPMI IP: 10.30.55.22
1076 - Host IP: 10.32.8.22
1078 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1079 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1080 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1081 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1082 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1083 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1084 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1085 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1086 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1087 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1088 - TG [Server-Type-C3]:
1089 - testbedname: testbed29.
1090 - hostname: s38-t29-tg1.
1091 - IPMI IP: 10.30.55.23
1092 - Host IP: 10.32.8.23
1094 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1095 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1096 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1097 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1098 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1099 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1100 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1101 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1102 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1103 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1106 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1109 - SUT [Server-Type-D1]:
1110 - testbedname: testbed210.
1111 - hostname: s60-t210-sut1.
1112 - IPMI IP: 10.30.55.24
1113 - Host IP: 10.32.8.24
1115 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1116 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1117 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1118 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1119 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1120 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1121 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1122 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1123 - TG [Server-Type-D2]:
1124 - testbedname: testbed210.
1125 - hostname: s61-t210-tg1.
1126 - IPMI IP: 10.30.55.25
1127 - Host IP: 10.32.8.25
1129 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1130 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1131 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1132 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1133 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1134 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1135 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1139 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1141 Note: Server19 (TG) is shared between testbed33 & testbed211
1144 - SUT [Server-Type-E22]:
1145 - testbedname: testbed211.
1146 - hostname: s27-t211-sut1.
1147 - IPMI IP: 10.30.50.69
1148 - Host IP: 10.30.51.69
1150 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1151 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1152 - TG [Server-Type-E31]:
1153 - testbedname: testbed33 and testbed211.
1154 - hostname: s19-t33t211-tg1.
1155 - IPMI IP: 10.30.50.46
1156 - Host IP: 10.30.51.49
1158 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1159 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1160 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1161 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1162 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1163 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1164 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1165 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1166 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1167 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1168 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1169 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1172 #### 2-Node-Icelake Servers (2n-icx) PROD
1175 - SUT [Server-Type-F1]:
1176 - testbedname: testbed212.
1177 - hostname: s71-t212-sut1.
1178 - IPMI IP: 10.30.51.81
1179 - Host IP: 10.30.50.81
1181 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1182 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1183 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1184 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1185 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1186 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1187 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1188 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1189 - TG [Server-Type-F2]:
1190 - testbedname: testbed212.
1191 - hostname: s72-t212-tg1.
1192 - IPMI IP: 10.30.51.82
1193 - Host IP: 10.30.50.82
1195 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1196 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1197 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1198 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1199 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1200 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1201 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1202 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1203 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1204 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1205 - SUT [Server-Type-F1]:
1206 - testbedname: testbed213.
1207 - hostname: s83-t213-sut1.
1208 - IPMI IP: 10.30.51.83
1209 - Host IP: 10.30.50.83
1211 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1212 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1213 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1214 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1215 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1216 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1217 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1218 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1219 - TG [Server-Type-F2]:
1220 - testbedname: testbed213.
1221 - hostname: s84-t213-tg1.
1222 - IPMI IP: 10.30.51.84
1223 - Host IP: 10.30.50.84
1225 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1226 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1227 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1228 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1229 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1230 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1231 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1232 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1233 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1234 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1235 - SUT [Server-Type-F1]:
1236 - testbedname: testbed214.
1237 - hostname: s85-t214-sut1.
1238 - IPMI IP: 10.30.51.85
1239 - Host IP: 10.30.50.85
1241 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1242 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1243 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1244 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1245 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1246 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1247 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1248 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1249 - TG [Server-Type-F2]:
1250 - testbedname: testbed214.
1251 - hostname: s86-t214-tg1.
1252 - IPMI IP: 10.30.51.86
1253 - Host IP: 10.30.50.86
1255 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1256 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1257 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1258 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1259 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1260 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1261 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1262 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1263 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1264 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1265 - SUT [Server-Type-F1]:
1266 - testbedname: testbed215.
1267 - hostname: s87-t215-sut1.
1268 - IPMI IP: 10.30.51.87
1269 - Host IP: 10.30.50.87
1271 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1272 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1273 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1274 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1275 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1276 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1277 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1278 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1279 - TG [Server-Type-F2]:
1280 - testbedname: testbed215.
1281 - hostname: s88-t215-tg1.
1282 - IPMI IP: 10.30.51.88
1283 - Host IP: 10.30.50.88
1285 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1286 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1287 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1288 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1289 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1290 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1291 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1292 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1293 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1294 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1297 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1299 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1302 - ServerB22 [Server-Type-B5]:
1303 - testbedname: testbed35.
1304 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1305 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1306 - Host IP: 10.30.51.9
1308 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1309 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1311 - ServerB23 [Server-Type-B5]:
1312 - testbedname: testbed35.
1313 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1314 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1315 - Host IP: 10.30.51.10
1317 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1318 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1320 - ServerB24 [Server-Type-B5]:
1321 - testbedname: testbed35.
1322 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1323 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1324 - Host IP: 10.30.51.11
1326 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1327 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1331 #### 3-Node-Taishan Servers (3n-tsh) PROD
1333 Note: Server19 (TG) is shared between testbed33 & testbed211
1336 - SUT [Server-Type-E21]:
1337 - testbedname: testbed33.
1338 - hostname: s17-t33-sut1.
1339 - IPMI IP: 10.30.50.36
1340 - Host IP: 10.30.51.36
1342 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1343 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1344 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1345 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1346 - SUT [Server-Type-E21]:
1347 - testbedname: testbed33.
1348 - hostname: s18-t33-sut2.
1349 - IPMI IP: 10.30.50.37
1350 - Host IP: 10.30.51.37
1352 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1353 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1354 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1355 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1356 - TG [Server-Type-E31]:
1357 - testbedname: testbed33 and testbed211.
1358 - hostname: s19-t33t211-tg1.
1359 - IPMI IP: 10.30.50.46
1360 - Host IP: 10.30.51.49
1362 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1363 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1364 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1365 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1366 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1367 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1368 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1369 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1370 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1371 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1372 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1373 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1376 #### 3-Node-Altra Servers (3n-alt) PROD
1379 - SUT [Server-Type-E23]:
1380 - testbedname: testbed34.
1381 - hostname: s62-t34-sut1.
1382 - IPMI IP: 10.30.50.72
1383 - Host IP: 10.30.51.72
1385 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1386 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1387 - SUT [Server-Type-E23]:
1388 - testbedname: testbed34.
1389 - hostname: s63-t34-sut2.
1390 - IPMI IP: 10.30.50.73
1391 - Host IP: 10.30.51.73
1393 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1394 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1395 - TG [Server-Type-F4]:
1396 - testbedname: testbed34.
1397 - hostname: s64-t34-tg1.
1398 - IPMI IP: 10.30.50.74
1399 - Host IP: 10.30.51.74
1401 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1402 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1403 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1404 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1405 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1406 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1407 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1408 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1409 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1410 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1413 #### 3-Node-Icelake Servers (3n-icx) PROD
1416 - ServerF1 [Server-Type-F1]:
1417 - testbedname: testbed37.
1418 - hostname: s65-t37-sut1.
1419 - IPMI IP: 10.30.50.75
1420 - Host IP: 10.30.51.75
1422 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1423 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1424 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1425 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1426 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1427 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1428 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1429 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1430 - ServerF1 [Server-Type-F1]:
1431 - testbedname: testbed37.
1432 - hostname: s66-t37-sut2.
1433 - IPMI IP: 10.30.50.76
1434 - Host IP: 10.30.51.76
1436 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1437 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1438 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1439 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1440 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1441 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1442 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1443 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1444 - ServerF3 [Server-Type-F3]:
1445 - testbedname: testbed37.
1446 - hostname: s67-t37-tg1.
1447 - IPMI IP: 10.30.50.77
1448 - Host IP: 10.30.51.77
1450 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1451 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1452 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1453 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1454 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1455 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1456 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1457 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1458 - ServerF1 [Server-Type-F1]:
1459 - testbedname: testbed38.
1460 - hostname: s78-t38-sut1.
1461 - IPMI IP: 10.30.50.78
1462 - Host IP: 10.30.51.78
1464 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1465 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1466 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1467 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1468 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1469 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1470 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1471 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1472 - ServerF1 [Server-Type-F1]:
1473 - testbedname: testbed38.
1474 - hostname: s79-t38-sut2.
1475 - IPMI IP: 10.30.50.79
1476 - Host IP: 10.30.51.79
1478 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1479 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1480 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1481 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1482 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1483 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1484 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1485 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1486 - ServerF3 [Server-Type-F3]:
1487 - testbedname: testbed38.
1488 - hostname: s80-t38-tg1.
1489 - IPMI IP: 10.30.50.80
1490 - Host IP: 10.30.51.80
1492 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1493 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1494 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1495 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1496 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1497 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1498 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1499 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1502 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1505 - ServerG1 [Server-Type-G1]:
1506 - testbedname: testbed39.
1507 - hostname: s93-t39-sut1.
1508 - IPMI IP: 10.30.50.93
1509 - Host IP: 10.30.51.93
1511 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1512 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1513 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1514 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1515 - ServerG1 [Server-Type-G1]:
1516 - testbedname: testbed39.
1517 - hostname: s94-t39-sut2.
1518 - IPMI IP: 10.30.50.94
1519 - Host IP: 10.30.51.94
1521 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1522 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1523 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1524 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1525 - ServerF4 [Server-Type-F4]:
1526 - testbedname: testbed39.
1527 - hostname: s89-t39t310-tg1.
1528 - IPMI IP: 10.30.50.89
1529 - Host IP: 10.30.51.89
1531 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1532 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1533 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1534 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1537 ### Per Testbed Wiring
1539 #### 1-Node-Skylake Wiring (1n-skx) PROD
1543 - ring1 10GE-ports x710-4p10GE:
1544 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1545 - ring2 10GE-ports x710-4p10GE:
1546 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1547 - ring3 10GE-ports x710-4p10GE:
1548 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1549 - ring4 10GE-ports x710-4p10GE:
1550 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1551 - ring5 100GE-ports e810-2p100GE:
1552 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1553 - ring6 100GE-ports e810-2p100GE:
1554 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1556 - ring1 10GE-ports x710-4p10GE:
1557 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1558 - ring2 10GE-ports x710-4p10GE:
1559 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1560 - ring3 10GE-ports x710-4p10GE:
1561 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1562 - ring4 10GE-ports x710-4p10GE:
1563 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1564 - ring5 100GE-ports e810-2p100GE:
1565 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1566 - ring6 100GE-ports e810-2p100GE:
1567 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1570 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1574 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1575 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1576 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1577 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1578 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1579 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1580 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1581 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1584 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1585 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1586 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1587 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1588 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1589 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1590 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1591 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1594 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1598 - link1 10GE-port x710-4p10GE on SUT:
1599 - t25-tg1-p1 to t25-sut1-c2/p1.
1600 - link2 10GE-port x710-4p10GE on SUT:
1601 - t25-tg1-p2 to t25-sut1-c2/p2.
1602 - link3 10GE-port x710-4p10GE on SUT:
1603 - t25-tg1-p3 to t25-sut1-c2/p3.
1604 - link4 10GE-port x710-4p10GE on SUT:
1605 - t25-tg1-p4 to t25-sut1-c2/p4.
1608 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1612 - ring1 10GE-ports x710-4p10GE on SUT:
1613 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1614 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1615 - ring2 10GE-ports x710-4p10GE on SUT:
1616 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1617 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1618 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1619 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1620 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1621 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1622 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1623 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1624 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1625 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1626 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1627 - ring6 100GE-ports e810-2p100GE on TG:
1628 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1629 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1631 - ring1 10GE-ports x710-4p10GE on SUT:
1632 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1633 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1634 - ring2 10GE-ports x710-4p10GE on SUT:
1635 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1636 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1637 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1638 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1639 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1640 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1641 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1642 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1643 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1644 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1645 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1646 - ring6 100GE-ports e810-2p100GE on TG:
1647 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1648 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1650 - ring1 10GE-ports x710-4p10GE on SUT:
1651 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1652 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1653 - ring2 10GE-ports x710-4p10GE on SUT:
1654 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1655 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1656 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1657 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1658 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1659 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1660 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1661 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1662 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1663 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1664 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1667 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1671 - ring1 10GE-ports x710-4p10GE on SUT:
1672 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1673 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1674 - ring2 10GE-ports x710-4p10GE on SUT:
1675 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1676 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1677 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1678 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1679 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1680 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1681 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1682 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1685 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1689 - ring1 10GE-ports x520-2p10GE on SUTs:
1690 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1691 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1694 #### 2-Node-Icelake Wiring (2n-icx) PROD
1698 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1699 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1700 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1701 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1702 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1703 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1704 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1705 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1706 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1707 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1708 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1709 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1710 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1711 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1713 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1714 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1715 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1716 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1717 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1718 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1719 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1720 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1721 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1722 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1723 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1724 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1725 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1726 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1728 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1729 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1730 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1731 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1732 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1733 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1734 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1735 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1736 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1737 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1738 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1739 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1740 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1741 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1743 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1744 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1745 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1746 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1747 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1748 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1749 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1750 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1751 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1752 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1753 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1754 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1755 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1756 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1759 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
1765 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1769 - ring1 10GE-ports x520-2p10GE on SUTs:
1770 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1771 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1772 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1773 - ring2 25GE-ports cx4-2p25GE on SUTs:
1774 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1775 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1776 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1779 #### 3-Node-Altra Wiring (3n-alt) PROD
1783 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1784 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1785 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1786 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1789 #### 3-Node-Icelake Wiring (3n-icx) PROD
1793 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1794 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1795 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1796 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1797 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1798 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1799 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1800 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1801 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1802 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1803 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1804 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1805 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1806 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1807 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1809 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1810 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1811 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1812 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1813 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1814 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1815 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1816 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1817 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1818 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1819 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1820 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1821 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1822 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1823 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1826 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
1830 - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
1831 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1832 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1833 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1834 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1835 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1836 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1844 1. Ixia PerfectStorm One Appliance
1846 - Chassis: PS10GE4NG.
1847 - Motherboard: SuperMicro X11DPG-QT.
1848 - Processors: Quad-Core, Intel Processor.
1849 - HW accelerators: FPGA offload.
1851 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1852 - Physical Interfaces: 4 * 10GE SFP+.
1853 - Operating System: Native IxOS.
1859 1. Arm Cortex A-72 servers
1860 - 2 * ThunderX2 (VPP Device)
1861 - Chassis: GIGABYTE Rack Mount
1862 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1863 - RAM Memory: 16* 16GB DIMM
1864 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1865 - 1 * ThunderX2 (Performance)
1866 - Chassis: GIGABYTE Rack Mount
1867 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1868 - RAM Memory: 4* 32GB RDIMM
1869 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1870 - 2 * Huawei TaiShan 2280.
1871 - Chassis: Huawei TaiShan 2280.
1872 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1873 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1874 - Disks: 1* 4TB SATA HDD.
1875 2. Arm Neoverse N1 servers
1876 - 2 * Ampere Altra (Performance)
1877 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
1878 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
1879 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
1880 - RAM Memory: 16* 8GB DDR4-3200MT/s
1881 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
1882 - 2 * Ampere Altra (Build)
1883 - Chassis: Gigabyte R152-P30-00 1U
1884 - Motherboard: MP32-AR1-00
1885 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
1886 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
1887 - RAM Memory: 12* 16GB DDR4-3200MT/s
1888 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
1891 ### Xeon and Atom Servers
1894 1. Intel Xeon servers:
1895 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1896 - Chassis: SuperMicro SYS-7049GP-TRT.
1897 - Motherboard: SuperMicro X11DPG-QT.
1898 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1899 - RAM Memory: 16* 16GB DDR4-2666MHz.
1900 - Disks: 2* 1.6TB 6G SATA SSD.
1901 2. Intel Atom servers with Rangely processors.
1902 - 3 * Netgate XG-2758-1u
1903 - Chassis: Netgate XG-2758-1u
1904 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1905 - RAM Memory: 16GB ECC
1909 ### Network Interface Cards
1922 ### Pluggables and Cables