1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
10 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
11 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
12 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
13 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
14 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
17 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
18 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
19 1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr)
20 1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr)
21 1. [Server Management](#server-management)
22 1. [Addressing](#addressing)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
30 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
32 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
33 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
34 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
35 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
36 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
37 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
38 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
39 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
40 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
41 1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
54 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
55 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
56 1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod)
60 This note includes specification of the physical testbed infrastructure
61 hosted by LFN FD.io CSIT project.
68 #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
69 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0
70 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0
71 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
72 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0
73 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0
74 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0
75 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0
76 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0
77 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0
78 10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0
79 11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
80 12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
81 13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
82 13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
83 Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
86 ### 1-Node-Skylake Xeon Intel (1n-skx)
88 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
89 ports connected back-to-back ([Server Types](#server-types)).
90 Used for FD.io VPP_Device functional driver tests.
92 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
94 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
95 ports connected back-to-back ([Server Types](#server-types)).
96 Used for FD.io VPP_Device functional driver tests.
98 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
100 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
101 NIC ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
105 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
107 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
108 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
109 circular topology ([Server Types](#server-types)).
110 Used for FD.io TCP/IP and HTTP performance tests.
112 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
114 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
115 one TG (Server-Type-C3) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
119 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
121 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
122 one TG (Server-Type-D2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
126 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
128 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
129 one TG (Server-Type-E31) connected in a 2-node circular topology
130 ([Server Types](#server-types)).
131 Used for FD.io performance tests.
133 ### 2-Node-Icelake Xeon Intel (2n-icx)
135 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
136 one TG (Server-Type-F2) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
140 ### 3-Node-Rangeley Atom Testbeds
142 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
143 TG (Server-Type-2) connected in a 3-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
147 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
149 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
150 TG (Server-Type-E31) connected in a 3-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
154 ### 3-Node-Altra Arm Ampere (3n-alt)
156 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
157 TG (Server-Type-F4) connected in a 3-node circular topology
158 ([Server Types](#server-types)).
159 Used for FD.io performance tests.
161 ### 3-Node-Icelake Xeon Intel (3n-icx)
163 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
164 TG (Server-Type-F3) connected in a 3-node circular topology
165 ([Server Types](#server-types)).
166 Used for FD.io performance tests.
168 ### 3-Node-SnowRidge Atom Intel (3n-snr)
170 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
171 TG (Server-Type-F4) connected in a 3-node circular topology
172 ([Server Types](#server-types)).
173 Used for FD.io performance tests.
175 ### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
177 One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and
178 one TG (Server-Type-H2) connected in a 2-node physical topology
179 with NUMA (socket) daisy chaining. For more detail see
180 [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
181 Used for FD.io performance tests in a full system SUT setup with all PCIe
182 Gen5 x16 lane slots populated with 2p200GbE NICs.
184 ### 2-Node-SapphireRapids Xeon Intel (2n-spr)
186 Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
187 one TG (Server-Type-H6) connected in a 2-node circular topology. For more
188 detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
189 Used for FD.io performance tests.
195 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
196 Management port, which are connected to two different VLANs.
200 - Subnet: 10.30.50.0/24
201 - Gateway: 10.30.50.1
202 - Broadcast: 10.30.50.255
203 - DNS1: 199.204.44.24
204 - DNS2: 199.204.47.54
206 - Subnet: 10.30.51.0/24
207 - Gateway: 10.30.51.1
208 - Broadcast: 10.30.51.255
209 - DNS1: 199.204.44.24
210 - DNS2: 199.204.47.54
213 To access these hosts, VPN connection is required.
215 ## Server Specifications
219 FD.io CSIT lab contains following server types:
221 1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
223 - Physical connectivity:
224 - IPMI and host management ports.
225 - Main HW configuration:
226 - Chassis: SuperMicro SYS-7049GP-TRT.
227 - Motherboard: SuperMicro X11DPG-QT.
228 - Processors: 2* Intel Platinum 8180 2.5 GHz.
229 - RAM Memory: 16* 16GB DDR4-2666MHz.
230 - Disks: 2* 1.6TB 6G SATA SSD.
231 - NICs configuration:
232 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
233 - PCIe Slot2 18:00.xx: empty.
234 - PCIe Slot4 3b:00.xx: empty.
235 - PCIe Slot9 5e:00.xx: empty.
236 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
237 - PCIe Slot6 86:00.xx: empty.
238 - PCIe Slot8 af:00.xx: empty.
239 - PCIe Slot10 d8:00.xx: empty.
240 2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
242 - Physical connectivity:
243 - IPMI and host management ports.
244 - NIC ports connected into 1-node topologies.
245 - Main HW configuration:
246 - Chassis: SuperMicro SYS-7049GP-TRT.
247 - Motherboard: SuperMicro X11DPG-QT.
248 - Processors: 2* Intel Platinum 8180 2.5 GHz.
249 - RAM Memory: 16* 16GB DDR4-2666MHz.
250 - Disks: 2* 1.6TB 6G SATA SSD.
251 - NICs configuration:
252 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
253 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
254 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
255 - PCIe Slot9 5e:00.xx: empty.
256 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
257 - PCIe Slot6 86:00.xx: empty.
258 - PCIe Slot8 af:00.xx: empty.
259 - PCIe Slot10 d8:00.xx: empty.
260 3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
262 - Physical connectivity:
263 - Host management interface: 10/100/1000-BaseT.
264 - 8-port 10GE SFP+ integrated NIC.
265 - Main HW configuration:
266 - Chassis: PS10GE4NG.
267 - Motherboard: SuperMicro X11DPG-QT.
268 - Processors: Quad-Core, Intel Processor.
269 - HW accelerators: FPGA offload.
271 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
272 - Physical Interfaces: 4 * 10GE SFP+.
273 - Operating System: Native IxOS.
274 - Interface configuration:
279 4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
281 - Physical connectivity:
282 - IPMI and host management ports.
284 - Main HW configuration:
285 - Chassis: SuperMicro SYS-7049GP-TRT.
286 - Motherboard: SuperMicro X11DPG-QT.
287 - Processors: 2* Intel Platinum 8180 2.5 GHz.
288 - RAM Memory: 16* 16GB DDR4-2666MHz.
289 - Disks: 2* 1.6TB 6G SATA SSD.
290 - NICs configuration:
291 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
292 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
293 - PCIe Slot4 3b:00.xx: empty.
294 - PCIe Slot9 5e:00.xx: empty.
295 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
296 - PCIe Slot6 86:00.xx: empty.
297 - PCIe Slot8 af:00.xx: empty.
298 - PCIe Slot10 d8:00.xx: empty.
299 5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
301 - Physical connectivity:
302 - IPMI and host management ports.
303 - NIC ports connected into 1-node testbed topologies.
304 - Main HW configuration:
305 - Chassis: SuperMicro SYS-7049GP-TRT.
306 - Motherboard: SuperMicro X11DPG-QT.
307 - Processors: 2* Intel Platinum 8280 2.7 GHz.
308 - RAM Memory: 12* 16GB DDR4-2933.
309 - Disks: 2* 1.92TB SATA SSD.
310 - NICs configuration:
311 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
312 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
313 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
314 - PCIe Slot9 5e:00.xx: empty.
315 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
316 - PCIe Slot6 86:00.xx: empty.
317 - PCIe Slot8 af:00.xx: empty.
318 - PCIe Slot10 d8:00.xx: empty.
319 6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
321 - Physical connectivity:
322 - IPMI and host management ports.
323 - NIC ports connected into 2-node testbed topologies.
324 - Main HW configuration:
325 - Chassis: SuperMicro SYS-7049GP-TRT.
326 - Motherboard: SuperMicro X11DPG-QT.
327 - Processors: 2* Intel Gold 6252N 2.3 GHz.
328 - RAM Memory: 12* 16GB DDR4-2933.
329 - Disks: 2* 1.92TB SATA SSD.
330 - NICs configuration:
331 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
332 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
333 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
334 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
335 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
336 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
337 - PCIe Slot8 af:00.xx: empty.
338 - PCIe Slot10 d8:00.xx: empty.
339 7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
341 - Physical connectivity:
342 - IPMI and host management ports.
343 - NIC ports connected into 2-node testbed topologies.
344 - Main HW configuration:
345 - Chassis: SuperMicro SYS-7049GP-TRT.
346 - Motherboard: SuperMicro X11DPG-QT.
347 - Processors: 2* Intel Platinum 8280 2.7 GHz.
348 - RAM Memory: 12* 16GB DDR4-2933.
349 - Disks: 2* 1.92TB SATA SSD.
350 - NICs configuration:
351 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
352 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
353 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
354 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
355 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
356 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
357 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
358 - PCIe Slot10 d8:00.xx: empty.
359 8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
361 - Physical connectivity:
362 - IPMI and host management ports.
363 - no NIC ports, standalone setup.
364 - Main HW configuration:
365 - Chassis: SuperMicro 1029P-WTRT.
366 - Motherboard: SuperMicro X11DDW-NT.
367 - Processors: 2* Intel Platinum 8280 2.7 GHz.
368 - RAM Memory: 12* 16GB DDR4-2933.
369 - Disks: 4* 1.92TB SATA SSD.
370 - NICs configuration:
375 9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
377 - Physical connectivity:
378 - IPMI and host management ports.
379 - NIC ports connected into 2-node testbed topologies.
380 - Main HW configuration:
381 - Chassis: SuperMicro AS-1114S-WTRT
382 - Processors: 1* AMD EPYC 7532 2.4 GHz.
383 - RAM Memory: 8* 32GB DDR4-2933.
384 - Disks: 1* 1TB SATA SSD.
385 - NICs configuration:
386 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
387 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
388 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
389 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
390 10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
392 - Physical connectivity:
393 - IPMI and host management ports.
394 - NIC ports connected into 2-node testbed topologies.
395 - Main HW configuration:
396 - Chassis: SuperMicro AS-1114S-WTRT
397 - Processors: 1* AMD EPYC 7532 2.4 GHz.
398 - RAM Memory: 8* 32GB DDR4-2933.
399 - Disks: 1* 1TB SATA SSD.
400 - NICs configuration:
401 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
402 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
403 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
404 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
405 11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
407 - Physical connectivity:
408 - IPMI and host management ports.
409 - NIC ports connected into 1-node topologies.
410 - Main HW configuration:
411 - Chassis: GIGABYTE Rack Mount
412 - Motherboard: MT91-FS4-00
413 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
414 - RAM Memory: 16 * 16GB DIMM
415 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
416 - NICs configuration:
418 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
419 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
421 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
422 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
423 12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
425 - Physical connectivity:
426 - IPMI(?) and host management ports.
427 - NIC ports connected into 3-node topology.
428 - Main HW configuration:
429 - Chassis: Huawei TaiShan 2280.
430 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
431 - RAM Memory: 8* 16GB DDR4-2400MT/s
432 - Disks: 1* 4TB SATA HDD
433 - NICs configuration:
434 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
435 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
436 13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
438 - Physical connectivity:
439 - IPMI and host management ports.
440 - NIC ports connected into 2-node topologies.
441 - Main HW configuration:
442 - Chassis: Gigabyte R181-T90 1U
443 - Motherboard: MT91-FS1
444 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
445 - RAM Memory: 4* 32GB RDIMM
446 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
447 - NICs configuration:
451 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
452 14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
454 - Physical connectivity:
455 - IPMI and host management ports.
456 - NIC ports connected into 3-node topologies.
457 - Main HW configuration:
458 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
459 - Motherboard: Mt.Jade Motherboard
460 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
461 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
462 - RAM Memory: 16* 8GB DDR4-3200MT/s
463 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
464 - NICs configuration:
466 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
469 15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
471 - Physical connectivity:
472 - IPMI and host management ports.
473 - Main HW configuration:
474 - Chassis: Gigabyte R152-P30-00 1U
475 - Motherboard: MP32-AR1-00
476 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
477 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
478 - RAM Memory: 12* 16GB DDR4-3200MT/s
479 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
480 16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
482 - Physical connectivity:
483 - IPMI and host management ports.
484 - NIC ports connected into 2-node and 3-node topologies.
485 - Main HW configuration:
486 - Chassis: SuperMicro SYS-7049GP-TRT.
487 - Motherboard: SuperMicro X11DPG-QT.
488 - Processors: 2* Intel Platinum 8180 2.5 GHz.
489 - RAM Memory: 16* 16GB DDR4-2666MHz.
490 - Disks: 2* 1.6TB 6G SATA SSD.
491 - NICs configuration:
492 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
493 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
494 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
495 - PCIe Slot9 5e:00.xx: empty.
496 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
497 - PCIe Slot6 86:00.xx: empty.
498 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
499 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
500 17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
502 - Physical connectivity:
503 - IPMI and host management ports.
504 - NIC ports connected into 2-node or 3-node testbed topologies.
505 - Main HW configuration:
506 - Chassis: SuperMicro SYS-740GP-TNRT.
507 - Motherboard: Super X12DPG-QT6.
508 - Processors: 2* Intel Platinum 8358 2.6 GHz.
509 - RAM Memory: 16* 16GB DDR4-3200.
510 - Disks: 2* 960GB SATA SSD.
511 - NICs configuration:
512 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
513 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
514 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
515 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
516 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
517 - PCIe Slot6 86:00.xx: empty.
518 - PCIe Slot8 af:00.xx: empty.
519 - PCIe Slot10 d8:00.xx: empty.
520 18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
522 - Physical connectivity:
523 - IPMI and host management ports.
524 - NIC ports connected into 2-node testbed topologies.
525 - Main HW configuration:
526 - Chassis: SuperMicro SYS-740GP-TNRT.
527 - Motherboard: Super X12DPG-QT6.
528 - Processors: 2* Intel Platinum 8358 2.6 GHz.
529 - RAM Memory: 16* 16GB DDR4-3200.
530 - Disks: 2* 960GB SATA SSD.
531 - NICs configuration:
532 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
533 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
534 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
535 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
536 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
537 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
538 - PCIe Slot8 af:00.xx: empty.
539 - PCIe Slot10 d8:00.xx: empty.
540 19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
542 - Physical connectivity:
543 - IPMI and host management ports.
544 - NIC ports connected into 3-node testbed topologies.
545 - Main HW configuration:
546 - Chassis: SuperMicro SYS-740GP-TNRT.
547 - Motherboard: Super X12DPG-QT6.
548 - Processors: 2* Intel Platinum 8358 2.6 GHz.
549 - RAM Memory: 16* 16GB DDR4-3200.
550 - Disks: 2* 960GB SATA SSD.
551 - NICs configuration:
552 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
553 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
554 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
555 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
556 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
557 - PCIe Slot6 86:00.xx: empty.
558 - PCIe Slot8 af:00.xx: empty.
559 - PCIe Slot10 d8:00.xx: empty.
560 20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
562 - Physical connectivity:
563 - IPMI and host management ports.
564 - NIC ports connected into 2-node and/or 3-node testbed topologies.
565 - Main HW configuration:
566 - Chassis: SuperMicro SYS-740GP-TNRT.
567 - Motherboard: Super X12DPG-QT6.
568 - Processors: 2* Intel Platinum 8358 2.6 GHz.
569 - RAM Memory: 16* 16GB DDR4-3200.
570 - Disks: 2* 960GB SATA SSD.
571 - NICs configuration:
572 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
573 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
574 - PCIe Slot4 3b:00.xx: empty.
575 - PCIe Slot9 5e:00.xx: empty.
576 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
577 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
578 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
579 - PCIe Slot10 d8:00.xx: empty.
580 21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
582 - Physical connectivity:
583 - IPMI and host management ports.
584 - NIC ports connected into 3-node testbed topology.
585 - Main HW configuration:
586 - Chassis: Intel JACOBSVILLE SDP.
587 - Motherboard: Intel JACOBSVILLE E63448-400.
588 - Processors: 1* Intel Atom P5362B 2.2 GHz.
589 - RAM Memory: 2* 16GB DDR4-2933.
590 - Disks: ?* ? SATA SSD.
591 - NICs configuration:
592 - Numa0: (x16, PCIe3.0 lane)
593 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
594 22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
596 - Physical connectivity:
597 - IPMI and host management ports.
598 - NIC ports connected into 3-numa-node testbed topologies.
599 - Main HW configuration:
600 - Chassis: SuperMicro SYS-741GE-TNRT.
601 - Motherboard: Super X13DEG-QT-P.
602 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
603 - RAM Memory: 16* 32GB DDR5-4800.
604 - Disks: 2* 960GB SATA SSD.
605 - NICs configuration:
606 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
607 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
608 - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
609 - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
610 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
611 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
612 - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
613 - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
614 23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
616 - Physical connectivity:
617 - IPMI and host management ports.
618 - NIC ports connected into 3-numa-node testbed topologies.
619 - Main HW configuration:
620 - Chassis: SuperMicro SYS-741GE-TNRT.
621 - Motherboard: Super X13DEG-QT-P.
622 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
623 - RAM Memory: 16* 32GB DDR5-4800.
624 - Disks: 2* 960GB SATA SSD.
625 - NICs configuration:
626 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
627 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
628 - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
629 - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
630 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
631 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
632 - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
633 - PCIe Slot11 d8:00.xx: empty.
634 24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
636 - Physical connectivity:
637 - IPMI and host management ports.
638 - NIC ports connected into 3-numa-node testbed topologies.
639 - Main HW configuration:
640 - Chassis: SuperMicro SYS-741GE-TNRT.
641 - Motherboard: Super X13DEG-QT-P.
642 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
643 - RAM Memory: 16* 32GB DDR5-4800.
644 - Disks: 2* 960GB SATA SSD.
645 - NICs configuration:
646 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
647 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
648 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
649 - PCIe Slot10 5e:00.xx: empty.
650 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
651 - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
652 - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
653 - PCIe Slot11 d8:00.xx: empty.
654 25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
656 - Physical connectivity:
657 - IPMI and host management ports.
658 - NIC ports connected into 3-numa-node testbed topologies.
659 - Main HW configuration:
660 - Chassis: SuperMicro SYS-741GE-TNRT.
661 - Motherboard: Super X13DEG-QT-P.
662 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
663 - RAM Memory: 16* 32GB DDR5-4800.
664 - Disks: 2* 960GB SATA SSD.
665 - NICs configuration:
666 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
667 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
668 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
669 - PCIe Slot10 5e:00.xx: empty.
670 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
671 - PCIe Slot7 86:00.xx: empty.
672 - PCIe Slot9 af:00.xx: empty.
673 - PCIe Slot11 d8:00.xx: empty.
674 26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
676 - Physical connectivity:
677 - IPMI and host management ports.
678 - NIC ports connected into 2-node testbed topologies.
679 - Main HW configuration:
680 - Chassis: SuperMicro SYS-741GE-TNRT.
681 - Motherboard: Super X13DEG-QT-P.
682 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
683 - RAM Memory: 16* 32GB DDR5-4800.
684 - Disks: 2* 960GB SATA SSD.
685 - NICs configuration:
686 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
687 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
688 - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
689 - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
690 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
691 - PCIe Slot7 86:00.xx: empty.
692 - PCIe Slot9 af:00.xx: empty.
693 - PCIe Slot11 d8:00.xx: empty.
694 27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
696 - Physical connectivity:
697 - IPMI and host management ports.
698 - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
699 - Main HW configuration:
700 - Chassis: SuperMicro SYS-741GE-TNRT.
701 - Motherboard: Super X13DEG-QT-P.
702 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
703 - RAM Memory: 16* 32GB DDR5-4800.
704 - Disks: 2* 960GB SATA SSD.
705 - NICs configuration:
706 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
707 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
708 - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
709 - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
710 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
711 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
712 - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
713 - PCIe Slot11 d8:00.xx: empty.
716 ### Naming Convention
718 Following naming convention is used within this page to specify physical
719 connectivity and wiring across defined CSIT testbeds:
722 - testbedname: testbedN.
724 - traffic-generator: tN-tgW.
725 - system-under-testX: tN-sutX.
730 - N - testbed number.
731 - tgW - server acts as traffic-generator with W index.
732 - sutX - server acts as system-under-test with X index.
733 - Y - PCIe slot number denoting a NIC card number within the host.
734 - Z - port number on the NIC card.
737 ## Testbeds Configuration
739 ### Per Testbed Server Allocation and Naming
741 #### 1-Node-Skylake Servers (1n-skx) PROD
744 - SUT [Server-Type-B6]:
745 - testbedname: testbed11.
746 - hostname: s1-t11-sut1.
747 - IPMI IP: 10.30.50.47
748 - Host IP: 10.30.51.50
750 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
751 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
752 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
753 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
754 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
755 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
756 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
757 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
758 - SUT [Server-Type-B6]:
759 - testbedname: testbed12.
760 - hostname: s2-t12-sut1.
761 - IPMI IP: 10.30.50.48
762 - Host IP: 10.30.51.51
764 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
765 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
766 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
767 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
768 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
769 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
770 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
771 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
774 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
777 - SUT [Server-Type-E11]:
778 - testbedname: testbed13
779 - hostname: s55-t13-sut1
780 - IPMI IP: 10.30.50.70
781 - Host IP: 10.30.51.70
783 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
784 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
785 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
786 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
787 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
788 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
789 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
790 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
791 - SUT [Server-Type-E11]:
792 - testbedname: testbed14
793 - hostname: s56-t14-sut1
794 - IPMI IP: 10.30.50.71
795 - Host IP: 10.30.51.71
797 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
798 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
799 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
800 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
801 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
802 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
803 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
804 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
807 #### 1-Node-Cascadelake Servers (1n-clx) PROD
810 - SUT [Server-Type-C1]:
811 - testbedname: testbed11.
812 - hostname: s32-t14-sut1.
813 - IPMI IP: 10.30.55.17
814 - Host IP: 10.32.8.17
816 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
817 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
818 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
819 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
820 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
821 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
822 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
823 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
826 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
829 - SUT [Server-Type-B8]:
830 - testbedname: testbed25.
831 - hostname: s25-t25-sut1.
832 - IPMI IP: 10.30.50.58
833 - Host IP: 10.30.51.61
835 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
836 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
837 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
838 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
839 - TG [Server-Type-B7]:
840 - testbedname: testbed25.
841 - hostname: s26-t25-tg1.
842 - IPMI IP: 10.30.50.59
843 - Host IP: 10.30.51.62
845 - s26-t25-tg1-p1 - 10GE-port1.
846 - s26-t25-tg1-p2 - 10GE-port2.
847 - s26-t25-tg1-p3 - 10GE-port3.
848 - s26-t25-tg1-p4 - 10GE-port4.
851 #### 2-Node-Cascadelake Servers (2n-clx) PROD
854 - SUT [Server-Type-C2]:
855 - testbedname: testbed27.
856 - hostname: s33-t27-sut1.
857 - IPMI IP: 10.30.55.18
858 - Host IP: 10.32.8.18
860 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
861 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
862 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
863 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
864 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
865 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
866 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
867 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
868 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
869 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
870 - TG [Server-Type-C3]:
871 - testbedname: testbed27.
872 - hostname: s34-t27-tg1.
873 - IPMI IP: 10.30.55.19
874 - Host IP: 10.32.8.19
876 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
877 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
878 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
879 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
880 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
881 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
882 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
883 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
884 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
885 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
886 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
887 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
888 - SUT [Server-Type-C2]:
889 - testbedname: testbed28.
890 - hostname: s35-t28-sut1.
891 - IPMI IP: 10.30.55.20
892 - Host IP: 10.32.8.20
894 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
895 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
896 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
897 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
898 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
899 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
900 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
901 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
902 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
903 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
904 - TG [Server-Type-C3]:
905 - testbedname: testbed28.
906 - hostname: s36-t28-tg1.
907 - IPMI IP: 10.30.55.21
908 - Host IP: 10.32.8.21
910 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
911 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
912 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
913 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
914 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
915 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
916 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
917 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
918 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
919 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
920 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
921 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
922 - SUT [Server-Type-C2]:
923 - testbedname: testbed29.
924 - hostname: s37-t29-sut1.
925 - IPMI IP: 10.30.55.22
926 - Host IP: 10.32.8.22
928 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
929 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
930 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
931 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
932 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
933 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
935 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
936 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
937 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
938 - TG [Server-Type-C3]:
939 - testbedname: testbed29.
940 - hostname: s38-t29-tg1.
941 - IPMI IP: 10.30.55.23
942 - Host IP: 10.32.8.23
944 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
945 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
946 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
947 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
948 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
949 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
950 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
951 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
952 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
953 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
956 #### 2-Node-Zen2 Servers (2n-zn2) PROD
959 - SUT [Server-Type-D1]:
960 - testbedname: testbed210.
961 - hostname: s60-t210-sut1.
962 - IPMI IP: 10.30.55.24
963 - Host IP: 10.32.8.24
965 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
966 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
967 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
968 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
969 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
970 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
971 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
972 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
973 - TG [Server-Type-D2]:
974 - testbedname: testbed210.
975 - hostname: s61-t210-tg1.
976 - IPMI IP: 10.30.55.25
977 - Host IP: 10.32.8.25
979 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
980 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
981 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
982 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
983 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
984 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
985 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
986 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
989 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
991 Note: Server19 (TG) is shared between testbed33 & testbed211
994 - SUT [Server-Type-E22]:
995 - testbedname: testbed211.
996 - hostname: s27-t211-sut1.
997 - IPMI IP: 10.30.50.69
998 - Host IP: 10.30.51.69
1000 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1001 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1002 - TG [Server-Type-E31]:
1003 - testbedname: testbed33 and testbed211.
1004 - hostname: s19-t33t211-tg1.
1005 - IPMI IP: 10.30.50.46
1006 - Host IP: 10.30.51.49
1008 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1009 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1010 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1011 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1012 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1013 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1014 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1015 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1016 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1017 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1018 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1019 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1022 #### 2-Node-Icelake Servers (2n-icx) PROD
1025 - SUT [Server-Type-F1]:
1026 - testbedname: testbed212.
1027 - hostname: s71-t212-sut1.
1028 - IPMI IP: 10.30.50.81
1029 - Host IP: 10.30.51.81
1031 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1032 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1033 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1034 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1035 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1036 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1037 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1038 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1039 - TG [Server-Type-F2]:
1040 - testbedname: testbed212.
1041 - hostname: s72-t212-tg1.
1042 - IPMI IP: 10.30.50.82
1043 - Host IP: 10.30.51.82
1045 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1046 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1047 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1048 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1049 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1050 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1051 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1052 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1053 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1054 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1055 - SUT [Server-Type-F1]:
1056 - testbedname: testbed213.
1057 - hostname: s83-t213-sut1.
1058 - IPMI IP: 10.30.50.83
1059 - Host IP: 10.30.51.83
1061 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1062 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1063 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1064 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1065 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1066 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1067 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1068 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1069 - TG [Server-Type-F2]:
1070 - testbedname: testbed213.
1071 - hostname: s84-t213-tg1.
1072 - IPMI IP: 10.30.50.84
1073 - Host IP: 10.30.51.84
1075 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1076 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1077 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1078 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1079 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1080 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1081 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1082 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1083 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1084 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1085 - SUT [Server-Type-F1]:
1086 - testbedname: testbed214.
1087 - hostname: s85-t214-sut1.
1088 - IPMI IP: 10.30.50.85
1089 - Host IP: 10.30.51.85
1091 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1092 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1093 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1094 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1095 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1096 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1097 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1098 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1099 - TG [Server-Type-F2]:
1100 - testbedname: testbed214.
1101 - hostname: s86-t214-tg1.
1102 - IPMI IP: 10.30.50.86
1103 - Host IP: 10.30.51.86
1105 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1106 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1107 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1108 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1109 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1110 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1111 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1112 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1113 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1114 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1115 - SUT [Server-Type-F1]:
1116 - testbedname: testbed215.
1117 - hostname: s87-t215-sut1.
1118 - IPMI IP: 10.30.50.87
1119 - Host IP: 10.30.51.87
1121 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1122 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1123 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1124 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1125 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1126 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1127 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1128 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1129 - TG [Server-Type-F2]:
1130 - testbedname: testbed215.
1131 - hostname: s88-t215-tg1.
1132 - IPMI IP: 10.30.50.88
1133 - Host IP: 10.30.51.88
1135 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1138 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1139 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1140 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1141 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1142 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1143 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1144 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1147 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1149 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1152 - ServerB22 [Server-Type-B5]:
1153 - testbedname: testbed35.
1154 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1155 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1156 - Host IP: 10.30.51.9
1158 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1159 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1161 - ServerB23 [Server-Type-B5]:
1162 - testbedname: testbed35.
1163 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1164 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1165 - Host IP: 10.30.51.10
1167 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1168 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1170 - ServerB24 [Server-Type-B5]:
1171 - testbedname: testbed35.
1172 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1173 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1174 - Host IP: 10.30.51.11
1176 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1177 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1181 #### 3-Node-Taishan Servers (3n-tsh) PROD
1183 Note: Server19 (TG) is shared between testbed33 & testbed211
1186 - SUT [Server-Type-E21]:
1187 - testbedname: testbed33.
1188 - hostname: s17-t33-sut1.
1189 - IPMI IP: 10.30.50.36
1190 - Host IP: 10.30.51.36
1192 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1193 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1194 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1195 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1196 - SUT [Server-Type-E21]:
1197 - testbedname: testbed33.
1198 - hostname: s18-t33-sut2.
1199 - IPMI IP: 10.30.50.37
1200 - Host IP: 10.30.51.37
1202 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1203 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1204 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1205 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1206 - TG [Server-Type-E31]:
1207 - testbedname: testbed33 and testbed211.
1208 - hostname: s19-t33t211-tg1.
1209 - IPMI IP: 10.30.50.46
1210 - Host IP: 10.30.51.49
1212 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1213 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1214 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1215 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1216 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1217 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1218 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1219 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1220 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1221 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1222 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1223 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1226 #### 3-Node-Altra Servers (3n-alt) PROD
1229 - SUT [Server-Type-E23]:
1230 - testbedname: testbed34.
1231 - hostname: s62-t34-sut1.
1232 - IPMI IP: 10.30.50.72
1233 - Host IP: 10.30.51.72
1235 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1236 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1237 - SUT [Server-Type-E23]:
1238 - testbedname: testbed34.
1239 - hostname: s63-t34-sut2.
1240 - IPMI IP: 10.30.50.73
1241 - Host IP: 10.30.51.73
1243 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1244 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1245 - TG [Server-Type-F4]:
1246 - testbedname: testbed34.
1247 - hostname: s64-t34-tg1.
1248 - IPMI IP: 10.30.50.74
1249 - Host IP: 10.30.51.74
1251 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1252 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1253 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1254 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1255 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1256 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1257 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1258 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1259 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1260 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1263 #### 3-Node-Icelake Servers (3n-icx) PROD
1266 - ServerF1 [Server-Type-F1]:
1267 - testbedname: testbed37.
1268 - hostname: s65-t37-sut1.
1269 - IPMI IP: 10.30.50.75
1270 - Host IP: 10.30.51.75
1272 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1273 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1274 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1275 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1276 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1277 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1278 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1279 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1280 - ServerF1 [Server-Type-F1]:
1281 - testbedname: testbed37.
1282 - hostname: s66-t37-sut2.
1283 - IPMI IP: 10.30.50.76
1284 - Host IP: 10.30.51.76
1286 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1287 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1288 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1289 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1290 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1291 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1292 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1293 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1294 - ServerF3 [Server-Type-F3]:
1295 - testbedname: testbed37.
1296 - hostname: s67-t37-tg1.
1297 - IPMI IP: 10.30.50.77
1298 - Host IP: 10.30.51.77
1300 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1301 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1302 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1303 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1304 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1305 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1306 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1307 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1308 - ServerF1 [Server-Type-F1]:
1309 - testbedname: testbed38.
1310 - hostname: s78-t38-sut1.
1311 - IPMI IP: 10.30.50.78
1312 - Host IP: 10.30.51.78
1314 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1315 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1316 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1317 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1318 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1319 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1320 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1321 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1322 - ServerF1 [Server-Type-F1]:
1323 - testbedname: testbed38.
1324 - hostname: s79-t38-sut2.
1325 - IPMI IP: 10.30.50.79
1326 - Host IP: 10.30.51.79
1328 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1329 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1330 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1331 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1332 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1333 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1334 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1335 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1336 - ServerF3 [Server-Type-F3]:
1337 - testbedname: testbed38.
1338 - hostname: s80-t38-tg1.
1339 - IPMI IP: 10.30.50.80
1340 - Host IP: 10.30.51.80
1342 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1343 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1344 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1345 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1346 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1347 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1348 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1349 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1352 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1355 - ServerG1 [Server-Type-G1]:
1356 - testbedname: testbed39.
1357 - hostname: s93-t39-sut1.
1358 - IPMI IP: 10.30.50.93
1359 - Host IP: 10.30.51.93
1361 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1362 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1363 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1364 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1365 - ServerG1 [Server-Type-G1]:
1366 - testbedname: testbed39.
1367 - hostname: s94-t39-sut2.
1368 - IPMI IP: 10.30.50.94
1369 - Host IP: 10.30.51.94
1371 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1372 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1373 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1374 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1375 - ServerF4 [Server-Type-F4]:
1376 - testbedname: testbed39.
1377 - hostname: s89-t39t310-tg1.
1378 - IPMI IP: 10.30.50.89
1379 - Host IP: 10.30.51.89
1381 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1382 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1383 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1384 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1387 #### 2-Node-SapphireRapids Servers (2n-spr) PROD
1390 - SUT [Server-Type-H1]:
1391 - testbedname: testbed21.
1392 - hostname: s52-t21-sut1.
1393 - IPMI IP: 10.30.50.52
1394 - Host IP: 10.30.51.52
1396 - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1397 - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1398 - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1399 - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1400 - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1401 - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1402 - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1403 - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1404 - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1405 - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1406 - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE.
1407 - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE.
1408 - TG [Server-Type-H2]:
1409 - testbedname: testbed21.
1410 - hostname: s53-t21-tg1.
1411 - IPMI IP: 10.30.50.53
1412 - Host IP: 10.30.51.53
1414 - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1415 - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1416 - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1417 - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1418 - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1419 - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1420 - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1421 - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1422 - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1423 - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1424 - SUT [Server-Type-H3]:
1425 - testbedname: testbed22.
1426 - hostname: s54-t22-sut1.
1427 - IPMI IP: 10.30.50.54
1428 - Host IP: 10.30.51.54
1430 - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1431 - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1432 - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1433 - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1434 - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1435 - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1436 - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1437 - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1438 - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1439 - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1440 - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1441 - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1442 - TG [Server-Type-H4]:
1443 - testbedname: testbed22.
1444 - hostname: s55-t22-tg1.
1445 - IPMI IP: 10.30.50.55
1446 - Host IP: 10.30.51.55
1448 - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1449 - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1450 - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1451 - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1452 - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1453 - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1454 - SUT [Server-Type-H5]:
1455 - testbedname: testbed23.
1456 - hostname: s56-t23-sut1.
1457 - IPMI IP: 10.30.50.56
1458 - Host IP: 10.30.51.56
1460 - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1461 - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1462 - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1463 - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1464 - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1465 - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1466 - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1467 - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1468 - TG [Server-Type-H6]:
1469 - testbedname: testbed23.
1470 - hostname: s57-t23-tg1.
1471 - IPMI IP: 10.30.50.57
1472 - Host IP: 10.30.51.57
1474 - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1475 - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1476 - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1477 - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1478 - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1479 - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1480 - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1481 - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1482 - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1483 - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1484 - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1485 - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1486 - SUT [Server-Type-H5]:
1487 - testbedname: testbed24.
1488 - hostname: s58-t24-sut1.
1489 - IPMI IP: 10.30.50.58
1490 - Host IP: 10.30.51.58
1492 - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1493 - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1494 - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1495 - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1496 - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1497 - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1498 - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1499 - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1500 - TG [Server-Type-H6]:
1501 - testbedname: testbed24.
1502 - hostname: s59-t24-tg1.
1503 - IPMI IP: 10.30.50.59
1504 - Host IP: 10.30.51.59
1506 - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1507 - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1508 - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1509 - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1510 - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1511 - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1512 - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1513 - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1514 - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1515 - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1516 - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1517 - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1520 ### Per Testbed Wiring
1522 #### 1-Node-Skylake Wiring (1n-skx) PROD
1526 - ring1 10GE-ports x710-4p10GE:
1527 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1528 - ring2 10GE-ports x710-4p10GE:
1529 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1530 - ring3 10GE-ports x710-4p10GE:
1531 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1532 - ring4 10GE-ports x710-4p10GE:
1533 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1534 - ring5 100GE-ports e810-2p100GE:
1535 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1536 - ring6 100GE-ports e810-2p100GE:
1537 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1539 - ring1 10GE-ports x710-4p10GE:
1540 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1541 - ring2 10GE-ports x710-4p10GE:
1542 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1543 - ring3 10GE-ports x710-4p10GE:
1544 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1545 - ring4 10GE-ports x710-4p10GE:
1546 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1547 - ring5 100GE-ports e810-2p100GE:
1548 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1549 - ring6 100GE-ports e810-2p100GE:
1550 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1553 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1557 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1558 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1559 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1560 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1561 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1562 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1563 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1564 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1567 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1568 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1569 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1570 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1571 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1572 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1573 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1574 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1577 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1581 - link1 10GE-port x710-4p10GE on SUT:
1582 - t25-tg1-p1 to t25-sut1-c2/p1.
1583 - link2 10GE-port x710-4p10GE on SUT:
1584 - t25-tg1-p2 to t25-sut1-c2/p2.
1585 - link3 10GE-port x710-4p10GE on SUT:
1586 - t25-tg1-p3 to t25-sut1-c2/p3.
1587 - link4 10GE-port x710-4p10GE on SUT:
1588 - t25-tg1-p4 to t25-sut1-c2/p4.
1591 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1595 - ring1 10GE-ports x710-4p10GE on SUT:
1596 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1597 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1598 - ring2 10GE-ports x710-4p10GE on SUT:
1599 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1600 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1601 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1602 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1603 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1604 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1605 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1606 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1607 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1608 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1609 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1610 - ring6 100GE-ports e810-2p100GE on TG:
1611 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1612 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1614 - ring1 10GE-ports x710-4p10GE on SUT:
1615 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1616 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1617 - ring2 10GE-ports x710-4p10GE on SUT:
1618 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1619 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1620 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1621 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1622 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1623 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1624 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1625 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1626 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1627 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1628 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1629 - ring6 100GE-ports e810-2p100GE on TG:
1630 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1631 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1633 - ring1 10GE-ports x710-4p10GE on SUT:
1634 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1635 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1636 - ring2 10GE-ports x710-4p10GE on SUT:
1637 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1638 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1639 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1640 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1641 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1642 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1643 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1644 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1645 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1646 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1647 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1650 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1654 - ring1 10GE-ports x710-4p10GE on SUT:
1655 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1656 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1657 - ring2 10GE-ports x710-4p10GE on SUT:
1658 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1659 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1660 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1661 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1662 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1663 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1664 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1665 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1668 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1672 - ring1 10GE-ports x520-2p10GE on SUTs:
1673 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1674 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1677 #### 2-Node-Icelake Wiring (2n-icx) PROD
1681 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1682 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1683 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1684 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1685 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1686 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1687 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1688 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1689 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1690 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1691 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1692 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1693 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1694 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1696 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1697 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1698 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1699 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1700 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1701 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1702 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1703 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1704 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1705 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1706 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1707 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1708 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1709 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1711 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1712 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1713 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1714 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1715 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1716 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1717 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1718 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1719 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1720 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1721 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1722 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1723 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1724 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1726 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1727 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1728 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1729 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1730 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1731 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1732 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1733 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1734 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1735 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1736 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1737 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1738 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1739 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1742 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
1748 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1752 - ring1 10GE-ports x520-2p10GE on SUTs:
1753 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1754 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1755 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1756 - ring2 25GE-ports cx4-2p25GE on SUTs:
1757 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1758 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1759 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1762 #### 3-Node-Altra Wiring (3n-alt) PROD
1766 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1767 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1768 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1769 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1772 #### 3-Node-Icelake Wiring (3n-icx) PROD
1776 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1777 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1778 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1779 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1780 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1781 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1782 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1783 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1784 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1785 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1786 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1787 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1788 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1789 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1790 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1792 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1793 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1794 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1795 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1796 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1797 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1798 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1799 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1800 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1801 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1802 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1803 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1804 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1805 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1806 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1809 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
1813 - ring1 25GE-ports e810-XXVDA4-4p25GE:
1814 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1815 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1816 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1817 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1818 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1819 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1822 #### 2-Node-SapphireRapids Wiring (2n-spr) PROD
1826 - ring1 200GE-ports ConnectX7-2p200GE:
1827 - s52-t21-tg1-c2/p1 to s53-t21-sut1-c2/p1
1828 - s52-t21-tg1-c7/p1 to s53-t21-sut1-c7/p1
1829 - s53-t21-sut1-c4/p2 to s53-t21-sut1-c9/p2
1830 - ring2 200GE-ports ConnectX7-2p200GE:
1831 - s52-t21-tg1-c2/p2 to s53-t21-sut1-c2/p2
1832 - s52-t21-tg1-c7/p2 to s53-t21-sut1-c7/p2
1833 - s53-t21-sut1-c10/p1 to s53-t21-sut1-c11/p1
1834 - ring3 200GE-ports ConnectX7-2p200GE:
1835 - s52-t21-tg1-c4/p1 to s53-t21-sut1-c4/p1
1836 - s52-t21-tg1-c9/p1 to s53-t21-sut1-c9/p1
1837 - s53-t21-sut1-c10/p2 to s53-t21-sut1-c11/p2
1839 - ring1 100GE-ports e810-2CQDA2-2p100GE:
1840 - s54-t22-tg1-c2/p1 to s55-t22-sut1-c2/p1
1841 - s54-t22-tg1-c2/p2 to s55-t22-sut1-c7/p1
1842 - s54-t22-sut1-c2/p2 to s55-t22-sut1-c7/p2
1843 - ring2 25GE-ports e810-XXVDA4-4p25GE:
1844 - s54-t22-tg1-c4/p1 to s55-t22-sut1-c4/p1
1845 - s54-t22-tg1-c4/p2 to s55-t22-sut1-c9/p1
1846 - s54-t22-sut1-c4/p2 to s55-t22-sut1-c9/p2
1848 - ring1 200GE-ports ConnectX7-2p200GE:
1849 - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
1850 - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
1851 - ring2 100GE-ports e810-2CQDA2-2p100GE:
1852 - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
1853 - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
1854 - ring3 25GE-ports e810-XXVDA4-2p25GE:
1855 - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
1856 - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
1857 - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
1858 - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
1859 - ring4 200GE-ports ConnectX7-2p200GE:
1860 - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
1861 - ring5 100GE-ports e810-2CQDA2-2p100GE:
1862 - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
1864 - ring1 200GE-ports ConnectX7-2p200GE:
1865 - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
1866 - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
1867 - ring2 100GE-ports e810-2CQDA2-2p100GE:
1868 - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
1869 - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
1870 - ring3 25GE-ports e810-XXVDA4-2p25GE:
1871 - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
1872 - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
1873 - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
1874 - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
1875 - ring4 200GE-ports ConnectX7-2p200GE:
1876 - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
1877 - ring5 100GE-ports e810-2CQDA2-2p100GE: