1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
15 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
36 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
37 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-wip)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
49 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
50 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-wip)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
72 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
74 3. 1-Node-Thunderx2 idle tx2 na 1 1 0 0 0 0 0 0 1 0 0 0
75 4. 1-Node-Thunderx2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
76 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
77 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
78 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
79 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
80 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
81 10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0
82 11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
83 12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
84 13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
85 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
86 15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
87 Totals: 27 36 16.5 12 18.5 1 2 3 3 2 7 2
90 ### 1-Node-Skylake Xeon Intel (1n-skx)
92 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
93 ports connected back-to-back ([Server Types](#server-types)).
94 Used for FD.io VPP_Device functional driver tests.
96 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
98 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
99 ports connected back-to-back ([Server Types](#server-types)).
100 Used for FD.io VPP_Device functional driver tests.
102 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
104 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
105 NIC ports connected back-to-back ([Server Types](#server-types)).
107 Used for FD.io VPP_Device functional driver tests.
109 ### 2-Node-Skylake Xeon Intel (2n-skx)
111 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
112 (Server-Type-B2) connected in a 2-node circular topology
113 ([Server Types](#server-types)).
114 Used for FD.io performance tests.
116 ### 2-Node-Denverton Atom Intel (2n-dnv)
118 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
119 TG (Server-Type-B2) connected in a 2-node circular topology
120 ([Server Types](#server-types)).
121 Used for FD.io performance tests.
123 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
125 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
126 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
127 circular topology ([Server Types](#server-types)).
128 Used for FD.io TCP/IP and HTTP performance tests.
130 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
132 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
133 one TG (Server-Type-C3) connected in a 2-node circular topology
134 ([Server Types](#server-types)).
135 Used for FD.io performance tests.
137 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
139 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
140 one TG (Server-Type-D2) connected in a 2-node circular topology
141 ([Server Types](#server-types)).
142 Used for FD.io performance tests.
144 ### 3-Node-Haswell Xeon Intel (3n-hsw)
146 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
147 TG (Server-Type-A2) connected in a 3-node circular topology
148 ([Server Types](#server-types)).
149 Used for FD.io performance tests.
151 ### 3-Node-Skylake Xeon Intel (3n-skx)
153 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
154 TG (Server-Type-B2) connected in a 3-node circular topology.
155 Used for FD.io performance tests.
157 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
159 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
160 TG (Server-Type-B2) connected in a 3-node circular topology
161 ([Server Types](#server-types)).
162 Used for FD.io performance tests.
164 ### 3-Node-Rangeley Atom Testbeds
166 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
167 TG (Server-Type-2) connected in a 3-node circular topology
168 ([Server Types](#server-types)).
169 Used for FD.io performance tests.
175 For management purposes, each server must have following two ports
176 connected to the management network:
180 - IPMI - Intelligent Platform Management Interface.
181 - Required for access to embedded server management with WebUI, CLI,
182 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
183 - 1GE/10GE/40GE management port
184 - hostOS management port for general system management.
189 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
190 Management port, which are connected to two different VLANs.
194 - Subnet: 10.30.50.0/24
195 - Gateway: 10.30.50.1
196 - Broadcast: 10.30.50.255
197 - DNS1: 199.204.44.24
198 - DNS2: 199.204.47.54
200 - Subnet: 10.30.51.0/24
201 - Gateway: 10.30.51.1
202 - Broadcast: 10.30.51.255
203 - DNS1: 199.204.44.24
204 - DNS2: 199.204.47.54
207 To access these hosts, VPN connection is required.
209 ### LOM (IPMI) VLAN IP Addresses
212 ------------ | -------
215 10.30.50.2 | LF Reserved
216 10.30.50.3 | LF Reserved
217 10.30.50.4 | LF Reserved
218 10.30.50.5 | LF Reserved
219 10.30.50.6 | LF Reserved
220 10.30.50.7 | LF Reserved
221 10.30.50.8 | LF Reserved
222 10.30.50.9 | LF Reserved
223 10.30.50.10 | LF Reserved
224 10.30.50.11 | LF Reserved
225 10.30.50.12 | LF Reserved
226 10.30.50.13 | LF Reserved
227 10.30.50.14 | LF Reserved
228 10.30.50.15 | LF Reserved
230 10.30.50.17 | t1-sut1
231 10.30.50.18 | t1-sut2
233 10.30.50.21 | t2-sut1
234 10.30.50.22 | t2-sut2
236 10.30.50.25 | t3-sut1
237 10.30.50.26 | t3-sut-2
238 10.30.50.28 | s41-nomad
239 10.30.50.29 | s39-nomad
240 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
241 10.30.50.30 | s40-nomad
242 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
243 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
244 10.30.50.32 | s42-nomad (formerly nomad1)
245 10.30.50.33 | s43-nomad (formerly nomad2)
246 10.30.50.34 | s44-nomad (formerly nomad3)
247 10.30.50.35 | s45-nomad (formerly nomad4)
248 10.30.50.36 | s17-t33-sut1
249 10.30.50.37 | s18-t33-sut2
250 10.30.50.38 | fdio-marvell-dev
251 10.30.50.39 | s53-nomad
252 10.30.50.40 | s54-nomad
253 10.30.50.41 | s3-t21-sut1
254 10.30.50.42 | s4-t21-tg1
255 10.30.50.43 | s11-t31-sut1
256 10.30.50.44 | s12-t31-sut2
257 10.30.50.45 | s13-t31-tg1
258 10.30.50.46 | s19-t33t34-tg1
259 10.30.50.47 | s1-t11-sut1
260 10.30.50.48 | s2-t12-sut1
261 10.30.50.49 | s5-t22-sut1
262 10.30.50.50 | s6-t22-tg1
263 10.30.50.51 | s7-t23-sut1
264 10.30.50.52 | s8-t23-tg1
265 10.30.50.53 | s9-t24-sut1
266 10.30.50.54 | s10-t24-tg1
267 10.30.50.55 | s14-t32-sut1
268 10.30.50.56 | s15-t32-sut2
269 10.30.50.57 | s16-t32-tg1
270 10.30.50.58 | s25-t25-sut1
271 10.30.50.59 | s26-t25-tg1
272 10.30.50.65 | s52-nomad
273 10.30.50.66 | s51-nomad
274 10.30.50.67 | s49-nomad
275 10.30.50.68 | s50-nomad
276 10.30.50.69 | s27-t13-sut
277 10.30.50.70 | s55-t36-sut1
278 10.30.50.71 | s56-t37-sut1
279 10.30.50.255 | Broadcast
284 10.30.55.10 | s28-t26t35-tg1
285 10.30.55.11 | s29-t26-sut1
286 10.30.55.12 | s30-t35-sut1
287 10.30.55.13 | s31-t35-sut2
288 10.30.55.14 | s46-nomad (formerly server-type-c4-1)
289 10.30.55.15 | s47-nomad (formerly server-type-c4-2)
290 10.30.55.16 | s48-nomad (formerly server-type-c4-3)
291 10.30.55.17 | s32-t14-sut1
292 10.30.55.18 | s33-t27-sut1
293 10.30.55.19 | s34-t27-tg1
294 10.30.55.20 | s35-t28-sut1
295 10.30.55.21 | s36-t28-tg1
296 10.30.55.22 | s37-t29-sut1
297 10.30.55.23 | s38-t29-tg1
298 10.30.55.24 | s60-t210-sut1
299 10.30.55.25 | s61-t210-tg1
300 10.30.55.255 | Broadcast
302 ### Management VLAN IP Addresses
305 ------------------------- | -------
308 10.30.51.2 | LF Reserved
309 10.30.51.3 | LF Reserved
310 10.30.51.4 | LF Reserved
311 10.30.51.5 | LF Reserved
312 10.30.51.6 | LF Reserved
313 10.30.51.7 | LF Reserved
314 10.30.51.8 | LF Reserved
315 10.30.51.9 | s22-t35-sut1 (netgate-1)
316 10.30.51.10 | s23-t35-sut2 (netgate-2)
317 10.30.51.11 | s24-t35-sut3 (netgate-3)
318 10.30.51.12 | softiron-1 (decommissioned)
319 10.30.51.13 | softiron-2 (decommissioned)
320 10.30.51.14 | softiron-3 (decommissioned)
321 10.30.51.15 | LF Reserved
323 10.30.51.17 | t1-sut1
324 10.30.51.18 | t1-sut2
326 10.30.51.21 | t2-sut1
327 10.30.51.22 | t2-sut2
329 10.30.51.25 | t3-sut1
330 10.30.51.26 | t3-sut-2
331 10.30.51.28 | s41-nomad
332 10.30.51.29 | s39-nomad
333 10.30.51.30 | s40-nomad
334 10.30.51.32 | s42-nomad (formerly nomad1)
335 10.30.51.33 | s43-nomad (formerly nomad2)
336 10.30.51.34 | s44-nomad (formerly nomad3)
337 10.30.51.35 | s45-nomad (formerly nomad4)
338 10.30.51.36 | s17-t33-sut1
339 10.30.51.37 | s18-t33-sut2
340 10.30.51.38 | fdio-marvell-dev
341 10.30.51.39 | s53-nomad
342 10.30.51.40 | s54-nomad
343 10.30.51.41 | s20-t34-sut1 (decommissioned)
344 10.30.51.42 | s21-t34-sut2 (decommissioned)
345 10.30.51.43 | fdio-mcbin3 (decommissioned)
346 10.30.51.44 | s3-t21-sut1
347 10.30.51.45 | s4-t21-tg1
348 10.30.51.46 | s11-t31-sut1
349 10.30.51.47 | s12-t31-sut2
350 10.30.51.48 | s13-t31-tg1
351 10.30.51.49 | s19-t33t34-tg1
352 10.30.51.50 | s1-t11-sut1
353 10.30.51.51 | s2-t12-sut1
354 10.30.51.52 | s5-t22-sut1
355 10.30.51.53 | s6-t22-tg1
356 10.30.51.54 | s7-t23-sut1
357 10.30.51.55 | s8-t23-tg1
358 10.30.51.56 | s9-t24-sut1
359 10.30.51.57 | s10-t24-tg1
360 10.30.51.58 | s14-t32-sut1
361 10.30.51.59 | s15-t32-sut2
362 10.30.51.60 | s16-t32-tg1
363 10.30.51.61 | s25-t25-sut1
364 10.30.51.62 | s26-t25-tg1
365 10.30.51.65 | s52-nomad
366 10.30.51.66 | s51-nomad
367 10.30.51.67 | s49-nomad
368 10.30.51.68 | s50-nomad
369 10.30.51.69 | s27-t13-sut1
370 10.30.51.70 | s55-t36-sut1
371 10.30.51.71 | s56-t37-sut1
372 10.30.51.72-10.30.51.105 | FREE
373 10.30.51.106-10.30.51.180 | FREE
374 10.30.51.181-10.30.51.254 | FREE
375 10.30.51.255 | Broadcast
378 10.32.8.10 | s28-t26t35-tg1
379 10.32.8.11 | s29-t26-sut1
380 10.32.8.12 | s30-t35-sut1
381 10.32.8.13 | s31-t35-sut2
382 10.32.8.14 | s46-nomad (formerly server-type-c4-1)
383 10.32.8.15 | s47-nomad (formerly server-type-c4-2)
384 10.32.8.16 | s48-nomad (formerly server-type-c4-3)
385 10.32.8.17 | s32-t14-sut1
386 10.32.8.18 | s33-t27-sut1
387 10.32.8.19 | s34-t27-tg1
388 10.32.8.20 | s35-t28-sut1
389 10.32.8.21 | s36-t28-tg1
390 10.32.8.22 | s37-t29-sut1
391 10.32.8.23 | s38-t29-tg1
392 10.32.8.24 | s60-t210-sut1
393 10.32.8.25 | s61-t210-tg1
394 10.32.8.255 | Broadcast
396 ## Server Specifications
400 FD.io CSIT lab contains following server types:
402 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
403 - Quantity: 6 servers.
404 - Physical connectivity:
405 - CIMC and host management ports.
406 - NIC ports connected in 3-node topologies.
407 - Main HW configuration:
408 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
409 - Processors: 2* E5-2699v3 2.3 GHz.
410 - RAM Memory: 16* 32GB DDR4-2133MHz.
411 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
412 - NICs configuration:
413 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
414 - PCIe Slot1: Cisco VIC 1385 2p40GE.
415 - PCIe Slot2: Intel NIC x520 2p10GE.
417 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
418 - PCIe Slot4: Intel NIC xl710 2p40GE.
419 - PCIe Slot5: Intel NIC x710 2p10GE.
420 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
421 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
422 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
423 - Quantity: 3 servers.
424 - Physical connectivity:
425 - CIMC and host management ports.
426 - NIC ports connected in 3-node topologies.
427 - Main HW configuration:
428 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
429 - Processors: 2* E5-2699v3 2.3 GHz.
430 - RAM Memory: 16* 32GB DDR4-2133MHz.
431 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
432 - NICs configuration:
433 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
434 - PCIe Slot1: Intel NIC xl710 2p40GE.
435 - PCIe Slot2: Intel NIC x710 2p10GE.
436 - PCIe Slot3: Intel NIC x710 2p10GE.
437 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
438 - PCIe Slot4: Intel NIC xl710 2p40GE.
439 - PCIe Slot5: Intel NIC x710 2p10GE.
440 - PCIe Slot6: Intel NIC x710 2p10GE.
442 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
443 - Quantity: 3 servers.
444 - Physical connectivity:
445 - CIMC and host management ports.
446 - no NIC ports, standalone setup.
447 - Main HW configuration:
448 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
449 - Processors: 2* E5-2699v3 2.3 GHz.
450 - RAM Memory: 16* 32GB DDR4-2133MHz.
451 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
452 - NICs configuration:
453 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
455 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
458 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
460 - Physical connectivity:
461 - IPMI and host management ports.
462 - NIC ports connected into 2-node and 3-node topologies.
463 - Main HW configuration:
464 - Chassis: SuperMicro SYS-7049GP-TRT.
465 - Motherboard: SuperMicro X11DPG-QT.
466 - Processors: 2* Intel Platinum 8180 2.5 GHz.
467 - RAM Memory: 16* 16GB DDR4-2666MHz.
468 - Disks: 2* 1.6TB 6G SATA SSD.
469 - NICs configuration:
470 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
471 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
472 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
473 - PCIe Slot9 5e:00.xx: empty.
474 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
475 - PCIe Slot6 86:00.xx: empty.
476 - PCIe Slot8 af:00.xx: empty.
477 - PCIe Slot10 d8:00.xx: empty.
478 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
480 - Physical connectivity:
481 - IPMI and host management ports.
482 - NIC ports connected into 2-node and 3-node topologies.
483 - Main HW configuration:
484 - Chassis: SuperMicro SYS-7049GP-TRT.
485 - Motherboard: SuperMicro X11DPG-QT.
486 - Processors: 2* Intel Platinum 8180 2.5 GHz.
487 - RAM Memory: 16* 16GB DDR4-2666MHz.
488 - Disks: 2* 1.6TB 6G SATA SSD.
489 - NICs configuration:
490 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
491 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
492 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
493 - PCIe Slot9 5e:00.xx: empty.
494 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
495 - PCIe Slot6 86:00.xx: empty.
496 - PCIe Slot8 af:00.xx: empty.
497 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
498 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
500 - Physical connectivity:
501 - IPMI(?) and host management ports.
502 - NIC ports connected into 3-node topology.
503 - Main HW configuration:
504 - Chassis: Huawei TaiShan 2280.
505 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
506 - RAM Memory: 8* 16GB DDR4-2400MT/s
507 - Disks: 1* 4TB SATA HDD
508 - NICs configuration:
509 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
510 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
511 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
512 - Quantity: TBD based on testbed allocation.
513 - Physical connectivity:
514 - Management: serial Port (usb) for console
515 - NIC ports connected into 2-node.
516 - Main HW configuration:
517 - Chassis: Netgate XG-2758-1u
518 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
519 - RAM Memory: 16GB ECC
521 - NICs configuration:
522 - 2x 10Gb Intel 82599ES
524 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
526 - Physical connectivity:
527 - IPMI and host management ports.
528 - NIC ports connected into 1-node topologies.
529 - Main HW configuration:
530 - Chassis: SuperMicro SYS-7049GP-TRT.
531 - Motherboard: SuperMicro X11DPG-QT.
532 - Processors: 2* Intel Platinum 8180 2.5 GHz.
533 - RAM Memory: 16* 16GB DDR4-2666MHz.
534 - Disks: 2* 1.6TB 6G SATA SSD.
535 - NICs configuration:
536 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
537 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
538 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
539 - PCIe Slot9 5e:00.xx: empty.
540 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
541 - PCIe Slot6 86:00.xx: empty.
542 - PCIe Slot8 af:00.xx: empty.
543 - PCIe Slot10 d8:00.xx: empty.
544 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
546 - Physical connectivity:
547 - Host management interface: 10/100/1000-BaseT.
548 - 8-port 10GE SFP+ integrated NIC.
549 - Main HW configuration:
550 - Chassis: PS10GE4NG.
551 - Motherboard: SuperMicro X11DPG-QT.
552 - Processors: Quad-Core, Intel Processor.
553 - HW accelerators: FPGA offload.
555 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
556 - Physical Interfaces: 4 * 10GE SFP+.
557 - Operating System: Native IxOS.
558 - Interface configuration:
563 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
565 - Physical connectivity:
566 - IPMI and host management ports.
568 - Main HW configuration:
569 - Chassis: SuperMicro SYS-7049GP-TRT.
570 - Motherboard: SuperMicro X11DPG-QT.
571 - Processors: 2* Intel Platinum 8180 2.5 GHz.
572 - RAM Memory: 16* 16GB DDR4-2666MHz.
573 - Disks: 2* 1.6TB 6G SATA SSD.
574 - NICs configuration:
575 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
576 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
577 - PCIe Slot4 3b:00.xx: empty.
578 - PCIe Slot9 5e:00.xx: empty.
579 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
580 - PCIe Slot6 86:00.xx: empty.
581 - PCIe Slot8 af:00.xx: empty.
582 - PCIe Slot10 d8:00.xx: empty.
583 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle).
585 - Physical connectivity:
586 - IPMI and host management ports.
587 - NIC ports connected into 1-node topologies.
588 - Main HW configuration:
589 - Chassis: Gigabyte R181-T90 1U
590 - Motherboard: MT91-FS1
591 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
592 - RAM Memory: 4* 32GB RDIMM
593 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
594 - NICs configuration:
596 - PCIe Slot1 05:00.xx: XL710-QDA2.
597 - PCIe Slot3 08:00.xx: XL710-QDA2.
599 - PCIe Slot6 85:00.xx: XL710-QDA2.
600 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
602 - Physical connectivity:
603 - IPMI and host management ports.
605 - Main HW configuration:
606 - Chassis: SuperMicro SYS-E300-9A
607 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
608 - RAM Memory: 32GB ECC
610 - NICs configuration:
611 - 2x 10Gb Intel x553 fiber ports
612 - 2x 10Gb Intel x553 copper ports
613 - 4x 1GB Intel I350 ports
614 13. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests.
616 - Physical connectivity:
617 - IPMI and host management ports.
618 - NIC ports connected into 1-node topologies.
619 - Main HW configuration:
620 - Chassis: GIGABYTE Rack Mount
621 - Motherboard: MT91-FS4-00
622 - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz
623 - RAM Memory: 16 * 16GB DIMM
624 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
625 - NICs configuration:
627 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
628 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
630 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
631 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
633 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
635 - Physical connectivity:
636 - IPMI and host management ports.
637 - NIC ports connected into 1-node testbed topologies.
638 - Main HW configuration:
639 - Chassis: SuperMicro SYS-7049GP-TRT.
640 - Motherboard: SuperMicro X11DPG-QT.
641 - Processors: 2* Intel Platinum 8280 2.7 GHz.
642 - RAM Memory: 12* 16GB DDR4-2933.
643 - Disks: 2* 1.92TB SATA SSD.
644 - NICs configuration:
645 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
646 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
647 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
648 - PCIe Slot9 5e:00.xx: empty.
649 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
650 - PCIe Slot6 86:00.xx: empty.
651 - PCIe Slot8 af:00.xx: empty.
652 - PCIe Slot10 d8:00.xx: empty.
653 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
655 - Physical connectivity:
656 - IPMI and host management ports.
657 - NIC ports connected into 2-node testbed topologies.
658 - Main HW configuration:
659 - Chassis: SuperMicro SYS-7049GP-TRT.
660 - Motherboard: SuperMicro X11DPG-QT.
661 - Processors: 2* Intel Gold 6252N 2.3 GHz.
662 - RAM Memory: 12* 16GB DDR4-2933.
663 - Disks: 2* 1.92TB SATA SSD.
664 - NICs configuration:
665 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
666 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
667 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
668 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
669 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
670 - PCIe Slot6 86:00.xx: empty.
671 - PCIe Slot8 af:00.xx: empty.
672 - PCIe Slot10 d8:00.xx: empty.
673 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
675 - Physical connectivity:
676 - IPMI and host management ports.
677 - NIC ports connected into 2-node testbed topologies.
678 - Main HW configuration:
679 - Chassis: SuperMicro SYS-7049GP-TRT.
680 - Motherboard: SuperMicro X11DPG-QT.
681 - Processors: 2* Intel Platinum 8280 2.7 GHz.
682 - RAM Memory: 12* 16GB DDR4-2933.
683 - Disks: 2* 1.92TB SATA SSD.
684 - NICs configuration:
685 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
686 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
687 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
688 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
689 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
690 - PCIe Slot6 86:00.xx: empty.
691 - PCIe Slot8 af:00.xx: empty.
692 - PCIe Slot10 d8:00.xx: empty.
693 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
695 - Physical connectivity:
696 - CIMC and host management ports.
697 - no NIC ports, standalone setup.
698 - Main HW configuration:
699 - Chassis: SuperMicro 1029P-WTRT.
700 - Motherboard: SuperMicro X11DDW-NT.
701 - Processors: 2* Intel Platinum 8280 2.7 GHz.
702 - RAM Memory: 12* 16GB DDR4-2933.
703 - Disks: 4* 1.92TB SATA SSD.
704 - NICs configuration:
710 18. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
712 - Physical connectivity:
713 - IPMI and host management ports.
714 - NIC ports connected into 2-node testbed topologies.
715 - Main HW configuration:
716 - Chassis: SuperMicro AS-1114S-WTRT
717 - Processors: 1* AMD EPYC 7532 2.4 GHz.
718 - RAM Memory: 8* 32GB DDR4-2933.
719 - Disks: 1* 1TB SATA SSD.
720 - NICs configuration:
721 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
722 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
723 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
724 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
725 19. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
727 - Physical connectivity:
728 - IPMI and host management ports.
729 - NIC ports connected into 2-node testbed topologies.
730 - Main HW configuration:
731 - Chassis: SuperMicro AS-1114S-WTRT
732 - Processors: 1* AMD EPYC 7532 2.4 GHz.
733 - RAM Memory: 8* 32GB DDR4-2933.
734 - Disks: 1* 1TB SATA SSD.
735 - NICs configuration:
736 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
737 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
738 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
739 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
742 ### Naming Convention
744 Following naming convention is used within this page to specify physical
745 connectivity and wiring across defined CSIT testbeds:
748 - testbedname: testbedN.
750 - traffic-generator: tN-tgW.
751 - system-under-testX: tN-sutX.
756 - N - testbed number.
757 - tgW - server acts as traffic-generator with W index.
758 - sutX - server acts as system-under-test with X index.
759 - Y - PCIe slot number denoting a NIC card number within the host.
760 - Z - port number on the NIC card.
763 ## Testbeds Configuration
765 ### Per Testbed Server Allocation and Naming
767 #### 1-Node-Skylake Servers (1n-skx) PROD
770 - SUT [Server-Type-B6]:
771 - testbedname: testbed11.
772 - hostname: s1-t11-sut1.
773 - IPMI IP: 10.30.50.47
774 - Host IP: 10.30.51.50
776 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
777 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
778 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
779 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
780 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
781 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
782 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
783 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
784 - SUT [Server-Type-B6]:
785 - testbedname: testbed12.
786 - hostname: s2-t12-sut1.
787 - IPMI IP: 10.30.50.48
788 - Host IP: 10.30.51.51
790 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
791 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
792 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
793 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
794 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
795 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
796 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
797 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
800 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
803 - SUT [Server-Type-B11]:
804 - testbedname: testbed36
805 - hostname: s55-t36-sut1
806 - IPMI IP: 10.30.50.70
807 - Host IP: 10.30.51.70
809 - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
810 - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
811 - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
812 - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
813 - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
814 - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
815 - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
816 - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
818 - SUT [Server-Type-B11]:
819 - testbedname: testbed37
820 - hostname: s56-t37-sut1
821 - IPMI IP: 10.30.50.71
822 - Host IP: 10.30.51.71
824 - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
825 - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
826 - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
827 - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
828 - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
829 - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
830 - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
831 - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
834 #### 1-Node-Cascadelake Servers (1n-clx) PROD
837 - SUT [Server-Type-C1]:
838 - testbedname: testbed11.
839 - hostname: s32-t14-sut1.
840 - IPMI IP: 10.30.55.17
841 - Host IP: 10.32.8.17
843 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
844 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
845 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
846 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
847 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
848 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
849 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
850 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
853 #### 2-Node-Skylake Servers (2n-skx) PROD
856 - SUT [Server-Type-B1]:
857 - testbedname: testbed21.
858 - hostname: s3-t21-sut1.
859 - IPMI IP: 10.30.50.41
860 - Host IP: 10.30.51.44
862 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
863 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
864 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
865 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
866 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
867 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
868 - TG [Server-Type-B2]:
869 - testbedname: testbed21.
870 - hostname: s4-t21-tg1.
871 - IPMI IP: 10.30.50.42
872 - Host IP: 10.30.51.45
874 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
875 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
876 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
877 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
878 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
879 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
880 - SUT [Server-Type-B1]:
881 - testbedname: testbed22.
882 - hostname: s5-t22-sut1.
883 - IPMI IP: 10.30.50.49
884 - Host IP: 10.30.51.52
886 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
887 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
888 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
889 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
890 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
891 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
892 - TG [Server-Type-B2]:
893 - testbedname: testbed22.
894 - hostname: s6-t22-tg1.
895 - IPMI IP: 10.30.50.50
896 - Host IP: 10.30.51.53
898 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
899 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
900 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
901 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
902 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
903 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
904 - SUT [Server-Type-B1]:
905 - testbedname: testbed23.
906 - hostname: s7-t23-sut1.
907 - IPMI IP: 10.30.50.51
908 - Host IP: 10.30.51.54
910 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
911 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
912 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
913 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
914 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
915 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
916 - TG [Server-Type-B2]:
917 - testbedname: testbed23.
918 - hostname: s8-t23-tg1.
919 - IPMI IP: 10.30.50.52
920 - Host IP: 10.30.51.55
922 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
923 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
924 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
925 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
926 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
927 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
928 - SUT [Server-Type-B1]:
929 - testbedname: testbed24.
930 - hostname: s9-t24-sut1.
931 - IPMI IP: 10.30.50.53
932 - Host IP: 10.30.51.56
934 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
935 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
936 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
937 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
938 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
939 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
940 - TG [Server-Type-B2]:
941 - testbedname: testbed24.
942 - hostname: s10-t24-tg1.
943 - IPMI IP: 10.30.50.54
944 - Host IP: 10.30.51.57
946 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
947 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
948 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
949 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
950 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
951 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
954 #### 2-Node-Denverton Servers (2n-dnv) WIP
956 Note: ServerB28 (TG) is shared between testbed26 & testbed35
959 - TG [Server-Type-B2]:
960 - testbednames: testbed26 and testbed35.
961 - hostname: s28-t26t35-tg1.
962 - IPMI IP: 10.30.55.10
963 - Host IP: 10.32.8.10
965 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
966 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
967 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
968 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
969 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
970 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
971 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
972 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
973 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
974 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
975 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
976 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
977 - SUT [Server-Type-B10]:
978 - testbednames: testbed26.
979 - hostname: s29-t26-sut1.
980 - IPMI IP: 10.30.55.11
981 - Host IP: 10.32.8.11
983 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
984 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
985 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
986 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
989 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
992 - SUT [Server-Type-B8]:
993 - testbedname: testbed25.
994 - hostname: s25-t25-sut1.
995 - IPMI IP: 10.30.50.58
996 - Host IP: 10.30.51.61
998 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
999 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1000 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1001 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1002 - TG [Server-Type-B7]:
1003 - testbedname: testbed25.
1004 - hostname: s26-t25-tg1.
1005 - IPMI IP: 10.30.50.59
1006 - Host IP: 10.30.51.62
1008 - s26-t25-tg1-p1 - 10GE-port1.
1009 - s26-t25-tg1-p2 - 10GE-port2.
1010 - s26-t25-tg1-p3 - 10GE-port3.
1011 - s26-t25-tg1-p4 - 10GE-port4.
1014 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
1017 - SUT [Server-Type-C2]:
1018 - testbedname: testbed27.
1019 - hostname: s33-t27-sut1.
1020 - IPMI IP: 10.30.55.18
1021 - Host IP: 10.32.8.18
1023 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1024 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1025 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1026 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1027 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1028 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1029 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1030 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1031 - TG [Server-Type-C3]:
1032 - testbedname: testbed27.
1033 - hostname: s34-t27-tg1.
1034 - IPMI IP: 10.30.55.19
1035 - Host IP: 10.32.8.19
1037 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1038 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1039 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1040 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1041 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1042 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1043 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1044 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1045 - SUT [Server-Type-C2]:
1046 - testbedname: testbed28.
1047 - hostname: s35-t28-sut1.
1048 - IPMI IP: 10.30.55.20
1049 - Host IP: 10.32.8.20
1051 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1052 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1053 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1054 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1055 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1056 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1057 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1058 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1059 - TG [Server-Type-C3]:
1060 - testbedname: testbed28.
1061 - hostname: s36-t28-tg1.
1062 - IPMI IP: 10.30.55.21
1063 - Host IP: 10.32.8.21
1065 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1066 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1067 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1068 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1069 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1070 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1071 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1072 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1073 - SUT [Server-Type-C2]:
1074 - testbedname: testbed29.
1075 - hostname: s37-t29-sut1.
1076 - IPMI IP: 10.30.55.22
1077 - Host IP: 10.32.8.22
1079 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1080 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1081 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1082 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1083 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1084 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1085 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1086 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1087 - TG [Server-Type-C3]:
1088 - testbedname: testbed29.
1089 - hostname: s38-t29-tg1.
1090 - IPMI IP: 10.30.55.23
1091 - Host IP: 10.32.8.23
1093 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1094 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1095 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1096 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1097 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1098 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1099 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1100 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1103 #### 2-Node-Zen2 Servers (2n-zn2) SETUP
1106 - SUT [Server-Type-D1]:
1107 - testbedname: testbed210.
1108 - hostname: s60-t210-sut1.
1109 - IPMI IP: 10.30.55.24
1110 - Host IP: 10.32.8.24
1112 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1113 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1114 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1115 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1116 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1117 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1118 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1119 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1120 - TG [Server-Type-D2]:
1121 - testbedname: testbed210.
1122 - hostname: s61-t210-tg1.
1123 - IPMI IP: 10.30.55.25
1124 - Host IP: 10.32.8.25
1126 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1127 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1128 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1129 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1130 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1131 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1132 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1133 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1136 #### 3-Node-Haswell Servers (3n-hsw) PROD
1139 1. SUT [Server-Type-A1]:
1140 - testbedname: testbed1.
1141 - hostname: t1-sut1.
1142 - CIMC IP: 10.30.50.17
1143 - Host IP: 10.30.51.17
1145 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1146 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1147 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1148 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1149 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1150 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1151 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1152 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1153 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1154 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1155 2. SUT [Server-Type-A1]:
1156 - testbedname: testbed1.
1157 - hostname: t1-sut2.
1158 - CIMC IP: 10.30.50.18
1159 - Host IP: 10.30.51.18
1161 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1162 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1163 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1164 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1165 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1166 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1167 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1168 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1169 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1170 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1171 3. TG [Server-Type-A2]:
1172 - testbedname: testbed1.
1174 - CIMC IP: 10.30.50.16
1175 - Host IP: 10.30.51.16
1177 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1178 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1179 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1180 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1181 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1182 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1183 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1184 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1185 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1186 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1187 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1188 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1189 4. SUT [Server-Type-A1]:
1190 - testbedname: testbed2.
1191 - hostname: t2-sut1.
1192 - CIMC IP: 10.30.50.21
1193 - Host IP: 10.30.51.21
1195 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1196 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1197 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1198 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1199 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1200 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1201 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1202 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1203 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1204 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1205 5. SUT [Server-Type-A1]:
1206 - testbedname: testbed2.
1207 - hostname: t2-sut2.
1208 - CIMC IP: 10.30.50.22
1209 - Host IP: 10.30.51.22
1211 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1212 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1213 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1214 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1215 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1216 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1217 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1218 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1219 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1220 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1221 6. TG [Server-Type-A2]:
1222 - testbedname: testbed2.
1224 - CIMC IP: 10.30.50.20
1225 - Host IP: 10.30.51.20
1227 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1228 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1229 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1230 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1231 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1232 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1233 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1234 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1235 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1236 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1237 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1238 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1239 7. SUT [Server-Type-A1]:
1240 - testbedname: testbed3.
1241 - hostname: t3-sut1.
1242 - CIMC IP: 10.30.50.25
1243 - Host IP: 10.30.51.25
1245 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1246 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1247 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1248 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1249 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1250 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1251 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1252 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1253 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1254 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1255 8. SUT [Server-Type-A1]:
1256 - testbedname: testbed3.
1257 - hostname: t3-sut2.
1258 - CIMC IP: 10.30.50.26
1259 - Host IP: 10.30.51.26
1261 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1262 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1263 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1264 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1265 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1266 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1267 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1268 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1269 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1270 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1271 9. TG [Server-Type-A2]:
1272 - testbedname: testbed3.
1274 - CIMC IP: 10.30.50.24
1275 - Host IP: 10.30.51.24
1277 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1278 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1279 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1280 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1281 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1282 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1283 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1284 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1285 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1286 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1287 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1288 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1291 #### 3-Node-Skylake Servers (3n-skx) PROD
1294 - ServerB11 [Server-Type-B1]:
1295 - testbedname: testbed31.
1296 - hostname: s11-t31-sut1.
1297 - IPMI IP: 10.30.50.43
1298 - Host IP: 10.30.51.46
1300 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1301 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1302 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1303 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1304 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1305 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1306 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1307 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1308 - ServerB12 [Server-Type-B1]:
1309 - testbedname: testbed31.
1310 - hostname: s12-t31-sut2.
1311 - IPMI IP: 10.30.50.44
1312 - Host IP: 10.30.51.47
1314 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1315 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1316 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1317 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1318 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1319 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1320 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1321 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1322 - ServerB13 [Server-Type-B2]:
1323 - testbedname: testbed31.
1324 - hostname: s13-t31-tg1.
1325 - IPMI IP: 10.30.50.45
1326 - Host IP: 10.30.51.48
1328 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1329 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1330 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1331 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1332 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1333 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1334 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1335 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1336 - ServerB14 [Server-Type-B1]:
1337 - testbedname: testbed32.
1338 - hostname: s14-t32-sut1.
1339 - IPMI IP: 10.30.50.55
1340 - Host IP: 10.30.51.58
1342 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1343 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1344 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1345 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1346 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1347 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1348 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1349 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1350 - ServerB15 [Server-Type-B1]:
1351 - testbedname: testbed32.
1352 - hostname: s15-t32-sut2.
1353 - IPMI IP: 10.30.50.56
1354 - Host IP: 10.30.51.59
1356 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1357 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1358 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1359 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1360 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1361 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1362 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1363 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1364 - ServerB16 [Server-Type-B2]:
1365 - testbedname: testbed32.
1366 - hostname: s16-t32-tg1.
1367 - IPMI IP: 10.30.50.57
1368 - Host IP: 10.30.51.60
1370 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1371 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1372 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1373 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1374 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1375 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1376 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1377 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1380 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1382 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1385 - ServerB22 [Server-Type-B5]:
1386 - testbedname: testbed35.
1387 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1388 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1389 - Host IP: 10.30.51.9
1391 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1392 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1394 - ServerB23 [Server-Type-B5]:
1395 - testbedname: testbed35.
1396 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1397 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1398 - Host IP: 10.30.51.10
1400 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1401 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1403 - ServerB24 [Server-Type-B5]:
1404 - testbedname: testbed35.
1405 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1406 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1407 - Host IP: 10.30.51.11
1409 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1410 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1414 #### 3-Node-Taishan Servers (3n-tsh) PROD
1417 - ServerB17 [Server-Type-B3]:
1418 - testbedname: testbed33.
1419 - hostname: s17-t33-sut1.
1420 - IPMI IP: 10.30.50.36
1421 - Host IP: 10.30.51.36
1423 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1424 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1425 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1426 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1427 - ServerB18 [Server-Type-B3]:
1428 - testbedname: testbed33.
1429 - hostname: s18-t33-sut2.
1430 - IPMI IP: 10.30.50.37
1431 - Host IP: 10.30.51.37
1433 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1434 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1435 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1436 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1437 - ServerB19 [Server-Type-B2]:
1438 - testbedname: testbed33 and testbed34.
1439 - hostname: s19-t33t34-tg1.
1440 - IPMI IP: 10.30.50.46
1441 - Host IP: 10.30.51.49
1443 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1444 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1445 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1446 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1447 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1448 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1449 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1450 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1451 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1452 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1455 #### 3-Node-Denverton Servers (3n-dnv) WIP
1458 - ServerB30 [Server-Type-B10]:
1459 - testbednames: testbed35.
1460 - hostname: s30-t35-sut1.
1461 - IPMI IP: 10.30.55.12
1462 - Host IP: 10.32.8.12
1464 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1465 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1466 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1467 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1468 - ServerB31 [Server-Type-B10]:
1469 - testbednames: testbed35.
1470 - hostname: s31-t35-sut2.
1471 - IPMI IP: 10.30.55.13
1472 - Host IP: 10.32.8.13
1474 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1475 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1476 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1477 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1480 ### Per Testbed Wiring
1482 #### 1-Node-Skylake Wiring (1n-skx) PROD
1486 - ring1 10GE-ports x710-4p10GE:
1487 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1488 - ring2 10GE-ports x710-4p10GE:
1489 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1490 - ring3 10GE-ports x710-4p10GE:
1491 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1492 - ring4 10GE-ports x710-4p10GE:
1493 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1495 - ring1 10GE-ports x710-4p10GE:
1496 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1497 - ring2 10GE-ports x710-4p10GE:
1498 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1499 - ring3 10GE-ports x710-4p10GE:
1500 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1501 - ring4 10GE-ports x710-4p10GE:
1502 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1505 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1509 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1510 - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1511 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1512 - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1513 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1514 - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1515 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1516 - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1519 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1520 - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1521 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1522 - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1523 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1524 - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1525 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1526 - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1529 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1533 - ring1 10GE-ports x710-4p10GE:
1534 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1535 - ring2 10GE-ports x710-4p10GE:
1536 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1537 - ring3 10GE-ports x710-4p10GE:
1538 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1539 - ring4 10GE-ports x710-4p10GE:
1540 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1543 #### 2-Node-Skylake Wiring (2n-skx) PROD
1547 - ring1 10GE-ports x710-4p10GE on SUT:
1548 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1549 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1550 - ring2 10GE-ports x710-4p10GE on SUT:
1551 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1552 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1553 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1554 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1555 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1557 - ring1 10GE-ports x710-4p10GE on SUT:
1558 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1559 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1560 - ring2 10GE-ports x710-4p10GE on SUT:
1561 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1562 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1563 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1564 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1565 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1567 - ring1 10GE-ports x710-4p10GE on SUT:
1568 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1569 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1570 - ring2 10GE-ports x710-4p10GE on SUT:
1571 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1572 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1573 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1574 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1575 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1577 - ring1 10GE-ports x710-4p10GE on SUT:
1578 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1579 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1580 - ring2 10GE-ports x710-4p10GE on SUT:
1581 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1582 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1583 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1584 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1585 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1588 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1592 - ring1 10GE-ports x553 copper port on SUT:
1593 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1594 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1595 - ring2 10GE-ports x553 fiber port on SUT:
1596 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1597 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1600 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1604 - link1 10GE-port x710-4p10GE on SUT:
1605 - t25-tg1-p1 to t25-sut1-c2/p1.
1606 - link2 10GE-port x710-4p10GE on SUT:
1607 - t25-tg1-p2 to t25-sut1-c2/p2.
1608 - link3 10GE-port x710-4p10GE on SUT:
1609 - t25-tg1-p3 to t25-sut1-c2/p3.
1610 - link4 10GE-port x710-4p10GE on SUT:
1611 - t25-tg1-p4 to t25-sut1-c2/p4.
1614 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1618 - ring1 10GE-ports x710-4p10GE on SUT:
1619 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1620 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1621 - ring2 10GE-ports x710-4p10GE on SUT:
1622 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1623 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1624 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1625 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1626 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1627 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1628 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1629 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1631 - ring1 10GE-ports x710-4p10GE on SUT:
1632 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1633 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1634 - ring2 10GE-ports x710-4p10GE on SUT:
1635 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1636 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1637 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1638 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1639 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1640 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1641 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1642 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1644 - ring1 10GE-ports x710-4p10GE on SUT:
1645 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1646 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1647 - ring2 10GE-ports x710-4p10GE on SUT:
1648 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1649 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1650 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1651 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1652 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1653 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1654 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1655 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1658 #### 2-Node-Zen2 Wiring (2n-zen2) SETUP
1662 - ring1 10GE-ports x710-4p10GE on SUT:
1663 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1664 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1665 - ring2 10GE-ports x710-4p10GE on SUT:
1666 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1667 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1668 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1669 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1670 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1671 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1672 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1673 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1676 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1680 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1681 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1682 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1683 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1684 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1685 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1686 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1687 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1688 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1689 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1690 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1691 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1692 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1693 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1694 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1695 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1696 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1697 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1698 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1699 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1700 - TG loopback ports Intel NIC x710 2p10GE
1701 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1704 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1705 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1706 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1707 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1708 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1709 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1710 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1711 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1712 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1713 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1714 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1715 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1716 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1717 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1718 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1719 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1720 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1721 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1722 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1723 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1724 - TG loopback ports Intel NIC x710 2p10GE
1725 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1728 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1729 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1730 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1731 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1732 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1733 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1734 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1735 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1736 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1737 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1738 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1739 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1740 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1741 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1742 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1743 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1744 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1745 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1746 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1747 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1748 - TG loopback ports Intel NIC x710 2p10GE
1749 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1752 #### 3-Node-Skylake Wiring (3n-skx) PROD
1756 - ring1 10GE-ports x710-4p10GE on SUTs:
1757 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1758 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1759 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1760 - ring2 10GE-ports x710-4p10GE on SUT:
1761 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1762 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1763 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1764 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1765 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1766 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1767 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1768 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1769 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1770 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1771 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1772 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1773 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1774 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1776 - ring1 10GE-ports x710-4p10GE on SUTs:
1777 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1778 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1779 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1780 - ring2 10GE-ports x710-4p10GE on SUT:
1781 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1782 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1783 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1784 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1785 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1786 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1787 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1788 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1789 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1790 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1791 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1792 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1793 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1794 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1797 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1803 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1807 - ring1 10GE-ports x520-2p10GE on SUTs:
1808 - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1809 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1810 - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1811 - ring2 25GE-ports cx4-2p25GE on SUTs:
1812 - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1813 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1814 - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1817 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1821 - ring1 10GE-ports x553 copper port on SUTs:
1822 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1823 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1824 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1825 - ring2 10GE-ports x553 fiber port on SUTs:
1826 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1827 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1828 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1836 1. Ixia PerfectStorm One Appliance
1838 - Chassis: PS10GE4NG.
1839 - Motherboard: SuperMicro X11DPG-QT.
1840 - Processors: Quad-Core, Intel Processor.
1841 - HW accelerators: FPGA offload.
1843 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1844 - Physical Interfaces: 4 * 10GE SFP+.
1845 - Operating System: Native IxOS.
1851 1. Arm Cortex A-72 servers
1852 - 2 * ThunderX2 (VPP Device)
1853 - Chassis: GIGABYTE Rack Mount
1854 - Processors: 2* ThunderX2 CN9980 ~ 128* ThunderX2
1855 - RAM Memory: 16* 16GB DIMM
1856 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1857 - 1 * ThunderX2 (Idle)
1858 - Chassis: Marvell ThunderX2
1859 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1860 - RAM Memory: 4* 32GB RDIMM
1861 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1862 - 2 * Huawei TaiShan 2280.
1863 - Chassis: Huawei TaiShan 2280.
1864 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1865 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1866 - Disks: 1* 4TB SATA HDD.
1869 ### Xeon and Atom Servers
1872 1. Intel Xeon servers:
1873 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1874 - Chassis: SuperMicro SYS-7049GP-TRT.
1875 - Motherboard: SuperMicro X11DPG-QT.
1876 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1877 - RAM Memory: 16* 16GB DDR4-2666MHz.
1878 - Disks: 2* 1.6TB 6G SATA SSD.
1879 2. Intel Atom servers with Rangely processors.
1880 - 3 * Netgate XG-2758-1u
1881 - Chassis: Netgate XG-2758-1u
1882 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1883 - RAM Memory: 16GB ECC
1887 ### Network Interface Cards
1891 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1892 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1893 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1895 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1897 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1899 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1902 ### Pluggables and Cables
1908 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1909 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1915 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1926 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable