1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
16 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
19 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
20 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
21 1. [Server Management](#server-management)
22 1. [Requirements](#requirements)
23 1. [Addressing](#addressing)
24 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
25 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
26 1. [Server Specifications](#server-specifications)
27 1. [Server Types](#server-types)
28 1. [Naming Convention](#naming-convention)
29 1. [Testbeds Configuration](#testbeds-configuration)
30 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
31 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
32 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
33 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
34 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
35 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
36 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
37 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
38 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
39 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
40 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
41 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
42 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
43 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
44 1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd)
45 1. [3-Node-Icelake Servers (3n-icx) TBD](#3-node-icelake-servers-3n-icx-tbd)
46 1. [Per Testbed Wiring](#per-testbed-wiring)
47 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
48 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
49 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
50 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
51 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
52 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
53 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
54 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
55 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
56 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
57 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
58 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
59 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
60 1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd)
61 1. [3-Node-Icelake Wiring (3n-icx) TBD](#3-node-icelake-wiring-3n-icx-tbd)
62 1. [Inventory](#inventory)
63 1. [Appliances](#appliances)
64 1. [Arm Servers](#arm-servers)
65 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
66 1. [Network Interface Cards](#network-interface-cards)
67 1. [Pluggables and Cables](#pluggables-and-cables)
68 1. [Other Parts](#other-parts)
72 This note includes specification of the physical testbed infrastructure
73 hosted by LFN FD.io CSIT project.
80 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx
81 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0
82 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0
83 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
84 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0
85 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 0
86 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0
87 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0
88 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0
89 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0
90 10. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8
91 11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0
92 12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0
93 13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0
94 14. 3-Node-Altra perf alt icx 1 2 .5 0 0 0 0 0 0 0 2 0 0 .5
95 15. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0
96 16. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0
97 17. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 6
98 18. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0
99 Totals: 34 43 21.5 4 19 1 2 3 3 2 4 7 2 14.5
102 ### 1-Node-Skylake Xeon Intel (1n-skx)
104 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
105 ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
110 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
111 ports connected back-to-back ([Server Types](#server-types)).
112 Used for FD.io VPP_Device functional driver tests.
114 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
116 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
117 NIC ports connected back-to-back ([Server Types](#server-types)).
119 Used for FD.io VPP_Device functional driver tests.
121 ### 2-Node-Skylake Xeon Intel (2n-skx)
123 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
124 (Server-Type-B2) connected in a 2-node circular topology
125 ([Server Types](#server-types)).
126 Used for FD.io performance tests.
128 ### 2-Node-Denverton Atom Intel (2n-dnv)
130 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
131 TG (Server-Type-B2) connected in a 2-node circular topology
132 ([Server Types](#server-types)).
133 Used for FD.io performance tests.
135 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
137 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
138 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
139 circular topology ([Server Types](#server-types)).
140 Used for FD.io TCP/IP and HTTP performance tests.
142 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
144 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
145 one TG (Server-Type-C3) connected in a 2-node circular topology
146 ([Server Types](#server-types)).
147 Used for FD.io performance tests.
149 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
151 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
152 one TG (Server-Type-D2) connected in a 2-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
156 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
158 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
159 one TG (Server-Type-E31) connected in a 2-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
163 ### 2-Node-Icelake Xeon Intel (2n-icx)
165 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
166 one TG (Server-Type-F2) connected in a 2-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
170 ### 3-Node-Haswell Xeon Intel (3n-hsw)
172 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
173 TG (Server-Type-A2) connected in a 3-node circular topology
174 ([Server Types](#server-types)).
175 Used for FD.io performance tests.
177 ### 3-Node-Skylake Xeon Intel (3n-skx)
179 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
180 TG (Server-Type-B2) connected in a 3-node circular topology.
181 Used for FD.io performance tests.
183 ### 3-Node-Rangeley Atom Testbeds
185 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
186 TG (Server-Type-2) connected in a 3-node circular topology
187 ([Server Types](#server-types)).
188 Used for FD.io performance tests.
190 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
192 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
193 TG (Server-Type-E31) connected in a 3-node circular topology
194 ([Server Types](#server-types)).
195 Used for FD.io performance tests.
197 ### 3-Node-Altra Arm Ampere (3n-alt)
199 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
200 TG (Server-Type-F4) connected in a 3-node circular topology
201 ([Server Types](#server-types)).
202 Used for FD.io performance tests.
204 ### 3-Node-Icelake Xeon Intel (3n-icx)
206 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
207 TG (Server-Type-F3) connected in a 3-node circular topology
208 ([Server Types](#server-types)).
209 Used for FD.io performance tests.
215 For management purposes, each server must have following two ports
216 connected to the management network:
220 - IPMI - Intelligent Platform Management Interface.
221 - Required for access to embedded server management with WebUI, CLI,
222 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
223 - 1GE/10GE/40GE management port
224 - hostOS management port for general system management.
229 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
230 Management port, which are connected to two different VLANs.
234 - Subnet: 10.30.50.0/24
235 - Gateway: 10.30.50.1
236 - Broadcast: 10.30.50.255
237 - DNS1: 199.204.44.24
238 - DNS2: 199.204.47.54
240 - Subnet: 10.30.51.0/24
241 - Gateway: 10.30.51.1
242 - Broadcast: 10.30.51.255
243 - DNS1: 199.204.44.24
244 - DNS2: 199.204.47.54
247 To access these hosts, VPN connection is required.
249 ### LOM (IPMI) VLAN IP Addresses
252 ------------ | -------
255 10.30.50.2 | LF Reserved
256 10.30.50.3 | LF Reserved
257 10.30.50.4 | LF Reserved
258 10.30.50.5 | LF Reserved
259 10.30.50.6 | LF Reserved
260 10.30.50.7 | LF Reserved
261 10.30.50.8 | LF Reserved
262 10.30.50.9 | LF Reserved
263 10.30.50.10 | LF Reserved
264 10.30.50.11 | LF Reserved
265 10.30.50.12 | LF Reserved
266 10.30.50.13 | LF Reserved
267 10.30.50.14 | LF Reserved
268 10.30.50.15 | LF Reserved
269 10.30.50.22 | s42-nomad
270 10.30.50.24 | s43-nomad
271 10.30.50.25 | s44-nomad
272 10.30.50.26 | s45-nomad
273 10.30.50.28 | s41-nomad
274 10.30.50.29 | s39-nomad
275 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
276 10.30.50.30 | s40-nomad
277 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
278 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
279 10.30.50.36 | s17-t33-sut1
280 10.30.50.37 | s18-t33-sut2
281 10.30.50.38 | fdio-marvell-dev
282 10.30.50.39 | s53-nomad
283 10.30.50.40 | s54-nomad
284 10.30.50.41 | s3-t21-sut1
285 10.30.50.42 | s4-t21-tg1
286 10.30.50.43 | s11-t31-sut1
287 10.30.50.44 | s12-t31-sut2
288 10.30.50.45 | s13-t31-tg1
289 10.30.50.46 | s19-t33t211-tg1
290 10.30.50.47 | s1-t11-sut1
291 10.30.50.48 | s2-t12-sut1
292 10.30.50.49 | s5-t22-sut1
293 10.30.50.50 | s6-t22-tg1
294 10.30.50.51 | s7-t23-sut1
295 10.30.50.52 | s8-t23-tg1
296 10.30.50.53 | s9-t24-sut1
297 10.30.50.54 | s10-t24-tg1
298 10.30.50.55 | s14-t32-sut1
299 10.30.50.56 | s15-t32-sut2
300 10.30.50.57 | s16-t32-tg1
301 10.30.50.58 | s25-t25-sut1
302 10.30.50.59 | s26-t25-tg1
303 10.30.50.65 | s52-nomad
304 10.30.50.66 | s51-nomad
305 10.30.50.67 | s49-nomad
306 10.30.50.68 | s50-nomad
307 10.30.50.69 | s27-t211-sut1
308 10.30.50.70 | s55-t13-sut1
309 10.30.50.71 | s56-t14-sut1
310 10.30.50.72 | s62-t34-sut1
311 10.30.50.73 | s63-t34-sut2
312 10.30.50.74 | s64-t34t36-tg1
313 10.30.50.75 | s65-t37-sut1
314 10.30.50.76 | s66-t37-sut2
315 10.30.50.77 | s67-t37-tg1
316 10.30.50.78 | s68-t38-sut1
317 10.30.50.79 | s69-t38-sut2
318 10.30.50.80 | s70-t38-tg1
319 10.30.50.81 | s71-t212-sut1
320 10.30.50.82 | s72-t212-tg1
321 10.30.50.83 | s73-t213-sut1
322 10.30.50.84 | s74-t213-tg1
323 10.30.50.85 | s75-t214-sut1
324 10.30.50.86 | s76-t214-tg1
325 10.30.50.87 | s77-t215-sut1
326 10.30.50.88 | s78-t215-tg1
327 10.30.50.89 | s79-t39t310-tg1
328 10.30.50.90 | s80-t311t312-tg1
329 10.30.50.91 | s58-nomad
330 10.30.50.92 | s59-nomad
331 10.30.50.255 | Broadcast
334 10.30.55.10 | s28-t26t35-tg1
335 10.30.55.11 | s29-t26-sut1
336 10.30.55.12 | s30-t35-sut1
337 10.30.55.13 | s31-t35-sut2
338 10.30.55.14 | s46-nomad
339 10.30.55.15 | s47-nomad
340 10.30.55.16 | s48-nomad
341 10.30.55.17 | s57-nomad
342 10.30.55.18 | s33-t27-sut1
343 10.30.55.19 | s34-t27-tg1
344 10.30.55.20 | s35-t28-sut1
345 10.30.55.21 | s36-t28-tg1
346 10.30.55.22 | s37-t29-sut1
347 10.30.55.23 | s38-t29-tg1
348 10.30.55.24 | s60-t210-sut1
349 10.30.55.25 | s61-t210-tg1
350 10.30.55.255 | Broadcast
352 ### Management VLAN IP Addresses
355 -------------| -------
358 10.30.51.2 | LF Reserved
359 10.30.51.3 | LF Reserved
360 10.30.51.4 | LF Reserved
361 10.30.51.5 | LF Reserved
362 10.30.51.6 | LF Reserved
363 10.30.51.7 | LF Reserved
364 10.30.51.8 | LF Reserved
365 10.30.51.15 | LF Reserved
366 10.30.51.22 | s42-nomad
367 10.30.51.24 | s43-nomad
368 10.30.51.25 | s44-nomad
369 10.30.51.26 | s45-nomad
370 10.30.51.28 | s41-nomad
371 10.30.51.29 | s39-nomad
372 10.30.51.30 | s40-nomad
373 10.30.51.36 | s17-t33-sut1
374 10.30.51.37 | s18-t33-sut2
375 10.30.51.38 | fdio-marvell-dev
376 10.30.51.39 | s53-nomad
377 10.30.51.40 | s54-nomad
378 10.30.51.44 | s3-t21-sut1
379 10.30.51.45 | s4-t21-tg1
380 10.30.51.46 | s11-t31-sut1
381 10.30.51.47 | s12-t31-sut2
382 10.30.51.48 | s13-t31-tg1
383 10.30.51.49 | s19-t33t211-tg1
384 10.30.51.50 | s1-t11-sut1
385 10.30.51.51 | s2-t12-sut1
386 10.30.51.52 | s5-t22-sut1
387 10.30.51.53 | s6-t22-tg1
388 10.30.51.54 | s7-t23-sut1
389 10.30.51.55 | s8-t23-tg1
390 10.30.51.56 | s9-t24-sut1
391 10.30.51.57 | s10-t24-tg1
392 10.30.51.58 | s14-t32-sut1
393 10.30.51.59 | s15-t32-sut2
394 10.30.51.60 | s16-t32-tg1
395 10.30.51.61 | s25-t25-sut1
396 10.30.51.62 | s26-t25-tg1
397 10.30.51.65 | s52-nomad
398 10.30.51.66 | s51-nomad
399 10.30.51.67 | s49-nomad
400 10.30.51.68 | s50-nomad
401 10.30.51.69 | s27-t211-sut1
402 10.30.51.70 | s55-t13-sut1
403 10.30.51.71 | s56-t14-sut1
404 10.30.51.72 | s62-t34-sut1
405 10.30.51.73 | s63-t34-sut2
406 10.30.51.74 | s64-t34t36-tg1
407 10.30.51.75 | s65-t37-sut1
408 10.30.51.76 | s66-t37-sut2
409 10.30.51.77 | s67-t37-tg1
410 10.30.51.78 | s68-t38-sut1
411 10.30.51.79 | s69-t38-sut2
412 10.30.51.80 | s70-t38-tg1
413 10.30.51.81 | s71-t212-sut1
414 10.30.51.82 | s72-t212-tg1
415 10.30.51.83 | s73-t213-sut1
416 10.30.51.84 | s74-t213-tg1
417 10.30.51.85 | s75-t214-sut1
418 10.30.51.86 | s76-t214-tg1
419 10.30.51.87 | s77-t215-sut1
420 10.30.51.88 | s78-t215-tg1
421 10.30.51.89 | s79-t39t310-tg1
422 10.30.51.90 | s80-t311t312-tg1
423 10.30.51.91 | s58-nomad
424 10.30.51.92 | s59-nomad
425 10.30.51.255 | Broadcast
428 10.32.8.10 | s28-t26t35-tg1
429 10.32.8.11 | s29-t26-sut1
430 10.32.8.12 | s30-t35-sut1
431 10.32.8.13 | s31-t35-sut2
432 10.32.8.14 | s46-nomad
433 10.32.8.15 | s47-nomad
434 10.32.8.16 | s48-nomad
435 10.32.8.17 | s57-nomad
436 10.32.8.18 | s33-t27-sut1
437 10.32.8.19 | s34-t27-tg1
438 10.32.8.20 | s35-t28-sut1
439 10.32.8.21 | s36-t28-tg1
440 10.32.8.22 | s37-t29-sut1
441 10.32.8.23 | s38-t29-tg1
442 10.32.8.24 | s60-t210-sut1
443 10.32.8.25 | s61-t210-tg1
444 10.32.8.255 | Broadcast
446 ## Server Specifications
450 FD.io CSIT lab contains following server types:
452 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
453 - Quantity: 6 servers.
454 - Physical connectivity:
455 - CIMC and host management ports.
456 - NIC ports connected in 3-node topologies.
457 - Main HW configuration:
458 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
459 - Processors: 2* E5-2699v3 2.3 GHz.
460 - RAM Memory: 16* 32GB DDR4-2133MHz.
461 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
462 - NICs configuration:
463 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
467 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
471 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
472 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
473 - Quantity: 3 servers.
474 - Physical connectivity:
475 - CIMC and host management ports.
476 - NIC ports connected in 3-node topologies.
477 - Main HW configuration:
478 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
479 - Processors: 2* E5-2699v3 2.3 GHz.
480 - RAM Memory: 16* 32GB DDR4-2133MHz.
481 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
482 - NICs configuration:
483 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
487 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
492 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
493 - Quantity: 3 servers.
494 - Physical connectivity:
495 - CIMC and host management ports.
496 - no NIC ports, standalone setup.
497 - Main HW configuration:
498 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
499 - Processors: 2* E5-2699v3 2.3 GHz.
500 - RAM Memory: 16* 32GB DDR4-2133MHz.
501 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
502 - NICs configuration:
503 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
505 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
508 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
510 - Physical connectivity:
511 - IPMI and host management ports.
512 - NIC ports connected into 2-node and 3-node topologies.
513 - Main HW configuration:
514 - Chassis: SuperMicro SYS-7049GP-TRT.
515 - Motherboard: SuperMicro X11DPG-QT.
516 - Processors: 2* Intel Platinum 8180 2.5 GHz.
517 - RAM Memory: 16* 16GB DDR4-2666MHz.
518 - Disks: 2* 1.6TB 6G SATA SSD.
519 - NICs configuration:
520 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
521 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
522 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
523 - PCIe Slot9 5e:00.xx: empty.
524 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
525 - PCIe Slot6 86:00.xx: empty.
526 - PCIe Slot8 af:00.xx: empty.
527 - PCIe Slot10 d8:00.xx: empty.
528 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
530 - Physical connectivity:
531 - IPMI and host management ports.
532 - NIC ports connected into 2-node and 3-node topologies.
533 - Main HW configuration:
534 - Chassis: SuperMicro SYS-7049GP-TRT.
535 - Motherboard: SuperMicro X11DPG-QT.
536 - Processors: 2* Intel Platinum 8180 2.5 GHz.
537 - RAM Memory: 16* 16GB DDR4-2666MHz.
538 - Disks: 2* 1.6TB 6G SATA SSD.
539 - NICs configuration:
540 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
541 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
542 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
543 - PCIe Slot9 5e:00.xx: empty.
544 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
545 - PCIe Slot6 86:00.xx: empty.
546 - PCIe Slot8 af:00.xx: empty.
547 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
548 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
549 - Quantity: TBD based on testbed allocation.
550 - Physical connectivity:
551 - Management: serial Port (usb) for console
552 - NIC ports connected into 2-node.
553 - Main HW configuration:
554 - Chassis: Netgate XG-2758-1u
555 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
556 - RAM Memory: 16GB ECC
558 - NICs configuration:
559 - 2x 10Gb Intel 82599ES
561 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
563 - Physical connectivity:
564 - IPMI and host management ports.
565 - NIC ports connected into 1-node topologies.
566 - Main HW configuration:
567 - Chassis: SuperMicro SYS-7049GP-TRT.
568 - Motherboard: SuperMicro X11DPG-QT.
569 - Processors: 2* Intel Platinum 8180 2.5 GHz.
570 - RAM Memory: 16* 16GB DDR4-2666MHz.
571 - Disks: 2* 1.6TB 6G SATA SSD.
572 - NICs configuration:
573 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
574 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
575 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
576 - PCIe Slot9 5e:00.xx: empty.
577 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
578 - PCIe Slot6 86:00.xx: empty.
579 - PCIe Slot8 af:00.xx: empty.
580 - PCIe Slot10 d8:00.xx: empty.
581 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
583 - Physical connectivity:
584 - Host management interface: 10/100/1000-BaseT.
585 - 8-port 10GE SFP+ integrated NIC.
586 - Main HW configuration:
587 - Chassis: PS10GE4NG.
588 - Motherboard: SuperMicro X11DPG-QT.
589 - Processors: Quad-Core, Intel Processor.
590 - HW accelerators: FPGA offload.
592 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
593 - Physical Interfaces: 4 * 10GE SFP+.
594 - Operating System: Native IxOS.
595 - Interface configuration:
600 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
602 - Physical connectivity:
603 - IPMI and host management ports.
605 - Main HW configuration:
606 - Chassis: SuperMicro SYS-7049GP-TRT.
607 - Motherboard: SuperMicro X11DPG-QT.
608 - Processors: 2* Intel Platinum 8180 2.5 GHz.
609 - RAM Memory: 16* 16GB DDR4-2666MHz.
610 - Disks: 2* 1.6TB 6G SATA SSD.
611 - NICs configuration:
612 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
613 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
614 - PCIe Slot4 3b:00.xx: empty.
615 - PCIe Slot9 5e:00.xx: empty.
616 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
617 - PCIe Slot6 86:00.xx: empty.
618 - PCIe Slot8 af:00.xx: empty.
619 - PCIe Slot10 d8:00.xx: empty.
620 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
622 - Physical connectivity:
623 - IPMI and host management ports.
625 - Main HW configuration:
626 - Chassis: SuperMicro SYS-E300-9A
627 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
628 - RAM Memory: 32GB ECC
630 - NICs configuration:
631 - 2x 10Gb Intel x553 fiber ports
632 - 2x 10Gb Intel x553 copper ports
633 - 4x 1GB Intel I350 ports
634 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
636 - Physical connectivity:
637 - IPMI and host management ports.
638 - NIC ports connected into 1-node testbed topologies.
639 - Main HW configuration:
640 - Chassis: SuperMicro SYS-7049GP-TRT.
641 - Motherboard: SuperMicro X11DPG-QT.
642 - Processors: 2* Intel Platinum 8280 2.7 GHz.
643 - RAM Memory: 12* 16GB DDR4-2933.
644 - Disks: 2* 1.92TB SATA SSD.
645 - NICs configuration:
646 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
647 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
648 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
649 - PCIe Slot9 5e:00.xx: empty.
650 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
651 - PCIe Slot6 86:00.xx: empty.
652 - PCIe Slot8 af:00.xx: empty.
653 - PCIe Slot10 d8:00.xx: empty.
654 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
656 - Physical connectivity:
657 - IPMI and host management ports.
658 - NIC ports connected into 2-node testbed topologies.
659 - Main HW configuration:
660 - Chassis: SuperMicro SYS-7049GP-TRT.
661 - Motherboard: SuperMicro X11DPG-QT.
662 - Processors: 2* Intel Gold 6252N 2.3 GHz.
663 - RAM Memory: 12* 16GB DDR4-2933.
664 - Disks: 2* 1.92TB SATA SSD.
665 - NICs configuration:
666 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
667 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
668 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
669 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
670 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
671 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
672 - PCIe Slot8 af:00.xx: empty.
673 - PCIe Slot10 d8:00.xx: empty.
674 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
676 - Physical connectivity:
677 - IPMI and host management ports.
678 - NIC ports connected into 2-node testbed topologies.
679 - Main HW configuration:
680 - Chassis: SuperMicro SYS-7049GP-TRT.
681 - Motherboard: SuperMicro X11DPG-QT.
682 - Processors: 2* Intel Platinum 8280 2.7 GHz.
683 - RAM Memory: 12* 16GB DDR4-2933.
684 - Disks: 2* 1.92TB SATA SSD.
685 - NICs configuration:
686 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
687 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
688 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
689 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
690 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
691 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
692 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
693 - PCIe Slot10 d8:00.xx: empty.
694 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
696 - Physical connectivity:
697 - IPMI and host management ports.
698 - no NIC ports, standalone setup.
699 - Main HW configuration:
700 - Chassis: SuperMicro 1029P-WTRT.
701 - Motherboard: SuperMicro X11DDW-NT.
702 - Processors: 2* Intel Platinum 8280 2.7 GHz.
703 - RAM Memory: 12* 16GB DDR4-2933.
704 - Disks: 4* 1.92TB SATA SSD.
705 - NICs configuration:
710 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
712 - Physical connectivity:
713 - IPMI and host management ports.
714 - NIC ports connected into 2-node testbed topologies.
715 - Main HW configuration:
716 - Chassis: SuperMicro AS-1114S-WTRT
717 - Processors: 1* AMD EPYC 7532 2.4 GHz.
718 - RAM Memory: 8* 32GB DDR4-2933.
719 - Disks: 1* 1TB SATA SSD.
720 - NICs configuration:
721 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
722 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
723 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
724 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
725 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
727 - Physical connectivity:
728 - IPMI and host management ports.
729 - NIC ports connected into 2-node testbed topologies.
730 - Main HW configuration:
731 - Chassis: SuperMicro AS-1114S-WTRT
732 - Processors: 1* AMD EPYC 7532 2.4 GHz.
733 - RAM Memory: 8* 32GB DDR4-2933.
734 - Disks: 1* 1TB SATA SSD.
735 - NICs configuration:
736 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
737 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
738 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
739 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
740 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
742 - Physical connectivity:
743 - IPMI and host management ports.
744 - NIC ports connected into 1-node topologies.
745 - Main HW configuration:
746 - Chassis: GIGABYTE Rack Mount
747 - Motherboard: MT91-FS4-00
748 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
749 - RAM Memory: 16 * 16GB DIMM
750 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
751 - NICs configuration:
753 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
754 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
756 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
757 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
758 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
760 - Physical connectivity:
761 - IPMI(?) and host management ports.
762 - NIC ports connected into 3-node topology.
763 - Main HW configuration:
764 - Chassis: Huawei TaiShan 2280.
765 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
766 - RAM Memory: 8* 16GB DDR4-2400MT/s
767 - Disks: 1* 4TB SATA HDD
768 - NICs configuration:
769 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
770 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
771 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
773 - Physical connectivity:
774 - IPMI and host management ports.
775 - NIC ports connected into 2-node topologies.
776 - Main HW configuration:
777 - Chassis: Gigabyte R181-T90 1U
778 - Motherboard: MT91-FS1
779 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
780 - RAM Memory: 4* 32GB RDIMM
781 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
782 - NICs configuration:
784 - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
786 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
787 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
789 - Physical connectivity:
790 - IPMI and host management ports.
791 - NIC ports connected into 3-node topologies.
792 - Main HW configuration:
798 - NICs configuration:
800 - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
801 - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
803 - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
804 - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
805 21. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
807 - Physical connectivity:
808 - IPMI and host management ports.
809 - NIC ports connected into 2-node and 3-node topologies.
810 - Main HW configuration:
811 - Chassis: SuperMicro SYS-7049GP-TRT.
812 - Motherboard: SuperMicro X11DPG-QT.
813 - Processors: 2* Intel Platinum 8180 2.5 GHz.
814 - RAM Memory: 16* 16GB DDR4-2666MHz.
815 - Disks: 2* 1.6TB 6G SATA SSD.
816 - NICs configuration:
817 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
818 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
819 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
820 - PCIe Slot9 5e:00.xx: empty.
821 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
822 - PCIe Slot6 86:00.xx: empty.
823 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
824 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
825 22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
827 - Physical connectivity:
828 - IPMI and host management ports.
829 - NIC ports connected into 2-node or 3-node testbed topologies.
830 - Main HW configuration:
831 - Chassis: SuperMicro SYS-740GP-TNRT.
832 - Motherboard: Super X12DPG-QT6.
833 - Processors: 2* Intel Platinum 8358 2.6 GHz.
834 - RAM Memory: 16* 16GB DDR4-3200.
835 - Disks: 2* 960GB SATA SSD.
836 - NICs configuration:
837 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
838 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
839 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
840 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
841 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
842 - PCIe Slot6 86:00.xx: empty.
843 - PCIe Slot8 af:00.xx: empty.
844 - PCIe Slot10 d8:00.xx: empty.
845 23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
847 - Physical connectivity:
848 - IPMI and host management ports.
849 - NIC ports connected into 2-node testbed topologies.
850 - Main HW configuration:
851 - Chassis: SuperMicro SYS-740GP-TNRT.
852 - Motherboard: Super X12DPG-QT6.
853 - Processors: 2* Intel Platinum 8358 2.6 GHz.
854 - RAM Memory: 16* 16GB DDR4-3200.
855 - Disks: 2* 960GB SATA SSD.
856 - NICs configuration:
857 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
858 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
859 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
860 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
861 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
862 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
863 - PCIe Slot8 af:00.xx: empty.
864 - PCIe Slot10 d8:00.xx: empty.
865 24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
867 - Physical connectivity:
868 - IPMI and host management ports.
869 - NIC ports connected into 3-node testbed topologies.
870 - Main HW configuration:
871 - Chassis: SuperMicro SYS-740GP-TNRT.
872 - Motherboard: Super X12DPG-QT6.
873 - Processors: 2* Intel Platinum 8358 2.6 GHz.
874 - RAM Memory: 16* 16GB DDR4-3200.
875 - Disks: 2* 960GB SATA SSD.
876 - NICs configuration:
877 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
878 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
879 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
880 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
881 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
882 - PCIe Slot6 86:00.xx: empty.
883 - PCIe Slot8 af:00.xx: empty.
884 - PCIe Slot10 d8:00.xx: empty.
885 25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
887 - Physical connectivity:
888 - IPMI and host management ports.
889 - NIC ports connected into 2-node and/or 3-node testbed topologies.
890 - Main HW configuration:
891 - Chassis: SuperMicro SYS-740GP-TNRT.
892 - Motherboard: Super X12DPG-QT6.
893 - Processors: 2* Intel Platinum 8358 2.6 GHz.
894 - RAM Memory: 16* 16GB DDR4-3200.
895 - Disks: 2* 960GB SATA SSD.
896 - NICs configuration:
897 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
898 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
899 - PCIe Slot4 3b:00.xx: empty.
900 - PCIe Slot9 5e:00.xx: empty.
901 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
902 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
903 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
904 - PCIe Slot10 d8:00.xx: empty.
905 26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
907 - Physical connectivity:
908 - IPMI and host management ports.
909 - Main HW configuration:
910 - Chassis: Gigabyte R152-P30-00 1U
911 - Motherboard: MP32-AR1-00
912 - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1)
913 - RAM Memory: 4* 16GB RDIMM-3200MHz
914 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
917 ### Naming Convention
919 Following naming convention is used within this page to specify physical
920 connectivity and wiring across defined CSIT testbeds:
923 - testbedname: testbedN.
925 - traffic-generator: tN-tgW.
926 - system-under-testX: tN-sutX.
931 - N - testbed number.
932 - tgW - server acts as traffic-generator with W index.
933 - sutX - server acts as system-under-test with X index.
934 - Y - PCIe slot number denoting a NIC card number within the host.
935 - Z - port number on the NIC card.
938 ## Testbeds Configuration
940 ### Per Testbed Server Allocation and Naming
942 #### 1-Node-Skylake Servers (1n-skx) PROD
945 - SUT [Server-Type-B6]:
946 - testbedname: testbed11.
947 - hostname: s1-t11-sut1.
948 - IPMI IP: 10.30.50.47
949 - Host IP: 10.30.51.50
951 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
952 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
953 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
954 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
955 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
956 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
957 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
958 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
959 - SUT [Server-Type-B6]:
960 - testbedname: testbed12.
961 - hostname: s2-t12-sut1.
962 - IPMI IP: 10.30.50.48
963 - Host IP: 10.30.51.51
965 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
966 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
967 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
968 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
969 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
970 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
971 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
972 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
975 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
978 - SUT [Server-Type-E11]:
979 - testbedname: testbed13
980 - hostname: s55-t13-sut1
981 - IPMI IP: 10.30.50.70
982 - Host IP: 10.30.51.70
984 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
985 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
986 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
987 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
988 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
989 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
990 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
991 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
992 - SUT [Server-Type-E11]:
993 - testbedname: testbed14
994 - hostname: s56-t14-sut1
995 - IPMI IP: 10.30.50.71
996 - Host IP: 10.30.51.71
998 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
999 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1000 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1001 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1002 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1003 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1004 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1005 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1008 #### 1-Node-Cascadelake Servers (1n-clx) PROD
1011 - SUT [Server-Type-C1]:
1012 - testbedname: testbed11.
1013 - hostname: s32-t14-sut1.
1014 - IPMI IP: 10.30.55.17
1015 - Host IP: 10.32.8.17
1017 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1018 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1019 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1020 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1021 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1022 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1023 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1024 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1027 #### 2-Node-Skylake Servers (2n-skx) PROD
1030 - SUT [Server-Type-B1]:
1031 - testbedname: testbed21.
1032 - hostname: s3-t21-sut1.
1033 - IPMI IP: 10.30.50.41
1034 - Host IP: 10.30.51.44
1036 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1037 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1038 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1039 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1040 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1041 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1042 - TG [Server-Type-B2]:
1043 - testbedname: testbed21.
1044 - hostname: s4-t21-tg1.
1045 - IPMI IP: 10.30.50.42
1046 - Host IP: 10.30.51.45
1048 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1049 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1050 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1051 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1052 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1053 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1054 - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1055 - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1056 - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1057 - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1058 - SUT [Server-Type-B1]:
1059 - testbedname: testbed22.
1060 - hostname: s5-t22-sut1.
1061 - IPMI IP: 10.30.50.49
1062 - Host IP: 10.30.51.52
1064 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1065 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1066 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1067 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1068 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1069 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1070 - TG [Server-Type-B2]:
1071 - testbedname: testbed22.
1072 - hostname: s6-t22-tg1.
1073 - IPMI IP: 10.30.50.50
1074 - Host IP: 10.30.51.53
1076 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1077 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1078 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1079 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1080 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1081 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1082 - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1083 - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1084 - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1085 - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1086 - SUT [Server-Type-B1]:
1087 - testbedname: testbed23.
1088 - hostname: s7-t23-sut1.
1089 - IPMI IP: 10.30.50.51
1090 - Host IP: 10.30.51.54
1092 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1093 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1094 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1095 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1096 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1097 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1098 - TG [Server-Type-B2]:
1099 - testbedname: testbed23.
1100 - hostname: s8-t23-tg1.
1101 - IPMI IP: 10.30.50.52
1102 - Host IP: 10.30.51.55
1104 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1105 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1106 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1107 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1108 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1109 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1110 - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1111 - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1112 - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1113 - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1114 - SUT [Server-Type-B1]:
1115 - testbedname: testbed24.
1116 - hostname: s9-t24-sut1.
1117 - IPMI IP: 10.30.50.53
1118 - Host IP: 10.30.51.56
1120 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1121 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1122 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1123 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1124 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1125 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1126 - TG [Server-Type-B2]:
1127 - testbedname: testbed24.
1128 - hostname: s10-t24-tg1.
1129 - IPMI IP: 10.30.50.54
1130 - Host IP: 10.30.51.57
1132 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1133 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1134 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1135 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1136 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1137 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1138 - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1139 - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1140 - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1141 - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1144 #### 2-Node-Denverton Servers (2n-dnv) PROD
1146 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1149 - TG [Server-Type-B2]:
1150 - testbednames: testbed26 and testbed35.
1151 - hostname: s28-t26t35-tg1.
1152 - IPMI IP: 10.30.55.10
1153 - Host IP: 10.32.8.10
1155 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1156 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1157 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1158 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1159 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1160 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1161 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1162 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1163 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1164 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1165 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1166 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1167 - SUT [Server-Type-B10]:
1168 - testbednames: testbed26.
1169 - hostname: s29-t26-sut1.
1170 - IPMI IP: 10.30.55.11
1171 - Host IP: 10.32.8.11
1173 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1174 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1175 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1176 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1179 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1182 - SUT [Server-Type-B8]:
1183 - testbedname: testbed25.
1184 - hostname: s25-t25-sut1.
1185 - IPMI IP: 10.30.50.58
1186 - Host IP: 10.30.51.61
1188 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1189 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1190 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1191 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1192 - TG [Server-Type-B7]:
1193 - testbedname: testbed25.
1194 - hostname: s26-t25-tg1.
1195 - IPMI IP: 10.30.50.59
1196 - Host IP: 10.30.51.62
1198 - s26-t25-tg1-p1 - 10GE-port1.
1199 - s26-t25-tg1-p2 - 10GE-port2.
1200 - s26-t25-tg1-p3 - 10GE-port3.
1201 - s26-t25-tg1-p4 - 10GE-port4.
1204 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1207 - SUT [Server-Type-C2]:
1208 - testbedname: testbed27.
1209 - hostname: s33-t27-sut1.
1210 - IPMI IP: 10.30.55.18
1211 - Host IP: 10.32.8.18
1213 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1214 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1215 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1216 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1217 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1220 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1221 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1222 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1223 - TG [Server-Type-C3]:
1224 - testbedname: testbed27.
1225 - hostname: s34-t27-tg1.
1226 - IPMI IP: 10.30.55.19
1227 - Host IP: 10.32.8.19
1229 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1230 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1231 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1232 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1233 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1234 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1235 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1236 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1237 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1238 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1239 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1240 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1241 - SUT [Server-Type-C2]:
1242 - testbedname: testbed28.
1243 - hostname: s35-t28-sut1.
1244 - IPMI IP: 10.30.55.20
1245 - Host IP: 10.32.8.20
1247 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1248 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1249 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1250 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1251 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1252 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1253 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1254 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1255 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1256 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1257 - TG [Server-Type-C3]:
1258 - testbedname: testbed28.
1259 - hostname: s36-t28-tg1.
1260 - IPMI IP: 10.30.55.21
1261 - Host IP: 10.32.8.21
1263 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1264 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1265 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1266 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1267 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1268 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1269 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1270 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1271 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1272 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1273 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1274 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1275 - SUT [Server-Type-C2]:
1276 - testbedname: testbed29.
1277 - hostname: s37-t29-sut1.
1278 - IPMI IP: 10.30.55.22
1279 - Host IP: 10.32.8.22
1281 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1282 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1283 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1284 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1285 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1286 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1287 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1288 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1289 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1290 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1291 - TG [Server-Type-C3]:
1292 - testbedname: testbed29.
1293 - hostname: s38-t29-tg1.
1294 - IPMI IP: 10.30.55.23
1295 - Host IP: 10.32.8.23
1297 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1298 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1299 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1300 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1301 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1302 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1303 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1304 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1305 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1306 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1309 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1312 - SUT [Server-Type-D1]:
1313 - testbedname: testbed210.
1314 - hostname: s60-t210-sut1.
1315 - IPMI IP: 10.30.55.24
1316 - Host IP: 10.32.8.24
1318 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1319 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1320 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1321 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1322 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1323 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1324 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1325 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1326 - TG [Server-Type-D2]:
1327 - testbedname: testbed210.
1328 - hostname: s61-t210-tg1.
1329 - IPMI IP: 10.30.55.25
1330 - Host IP: 10.32.8.25
1332 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1333 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1334 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1335 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1336 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1337 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1338 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1339 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1342 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1344 Note: Server19 (TG) is shared between testbed33 & testbed211
1347 - SUT [Server-Type-E22]:
1348 - testbedname: testbed211.
1349 - hostname: s27-t211-sut1.
1350 - IPMI IP: 10.30.50.69
1351 - Host IP: 10.30.51.69
1353 - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1354 - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1355 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1356 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1357 - TG [Server-Type-E31]:
1358 - testbedname: testbed33 and testbed211.
1359 - hostname: s19-t33t211-tg1.
1360 - IPMI IP: 10.30.50.46
1361 - Host IP: 10.30.51.49
1363 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1364 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1365 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1366 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1367 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1368 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1369 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1370 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1371 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1372 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1373 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1374 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1377 #### 2-Node-Icelake Servers (2n-icx) TBD
1380 - SUT [Server-Type-F1]:
1381 - testbedname: testbed212.
1382 - hostname: s71-t212-sut1.
1383 - IPMI IP: 10.30.51.81
1384 - Host IP: 10.30.50.81
1386 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1387 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1388 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1389 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1390 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1391 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1392 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1393 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1394 - TG [Server-Type-F2]:
1395 - testbedname: testbed212.
1396 - hostname: s72-t212-tg1.
1397 - IPMI IP: 10.30.51.82
1398 - Host IP: 10.30.50.82
1400 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1401 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1402 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1403 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1404 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1405 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1406 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1407 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1408 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1409 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1410 - SUT [Server-Type-F1]:
1411 - testbedname: testbed213.
1412 - hostname: s73-t213-sut1.
1413 - IPMI IP: 10.30.51.83
1414 - Host IP: 10.30.50.83
1416 - s73-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1417 - s73-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1418 - s73-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1419 - s73-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1420 - s73-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1421 - s73-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1422 - s73-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1423 - s73-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1424 - TG [Server-Type-F2]:
1425 - testbedname: testbed213.
1426 - hostname: s74-t213-tg1.
1427 - IPMI IP: 10.30.51.84
1428 - Host IP: 10.30.50.84
1430 - s74-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1431 - s74-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1432 - s74-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1433 - s74-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1434 - s74-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1435 - s74-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1436 - s74-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1437 - s74-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1438 - s74-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1439 - s74-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1440 - SUT [Server-Type-F1]:
1441 - testbedname: testbed214.
1442 - hostname: s75-t214-sut1.
1443 - IPMI IP: 10.30.51.85
1444 - Host IP: 10.30.50.85
1446 - s75-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1447 - s75-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1448 - s75-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1449 - s75-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1450 - s75-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1451 - s75-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1452 - s75-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1453 - s75-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1454 - TG [Server-Type-F2]:
1455 - testbedname: testbed214.
1456 - hostname: s76-t214-tg1.
1457 - IPMI IP: 10.30.51.86
1458 - Host IP: 10.30.50.86
1460 - s76-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1461 - s76-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1462 - s76-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1463 - s76-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1464 - s76-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1465 - s76-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1466 - s76-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1467 - s76-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1468 - s76-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1469 - s76-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1470 - SUT [Server-Type-F1]:
1471 - testbedname: testbed215.
1472 - hostname: s77-t215-sut1.
1473 - IPMI IP: 10.30.51.87
1474 - Host IP: 10.30.50.87
1476 - s77-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1477 - s77-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1478 - s77-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1479 - s77-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1480 - s77-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1481 - s77-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1482 - s77-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1483 - s77-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1484 - TG [Server-Type-F2]:
1485 - testbedname: testbed215.
1486 - hostname: s78-t215-tg1.
1487 - IPMI IP: 10.30.51.88
1488 - Host IP: 10.30.50.88
1490 - s78-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1491 - s78-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1492 - s78-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1493 - s78-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1494 - s78-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1495 - s78-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1496 - s78-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1497 - s78-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1498 - s78-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1499 - s78-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1502 #### 3-Node-Skylake Servers (3n-skx) PROD
1505 - ServerB11 [Server-Type-B1]:
1506 - testbedname: testbed31.
1507 - hostname: s11-t31-sut1.
1508 - IPMI IP: 10.30.50.43
1509 - Host IP: 10.30.51.46
1511 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1512 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1513 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1514 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1515 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1516 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1517 - ServerB12 [Server-Type-B1]:
1518 - testbedname: testbed31.
1519 - hostname: s12-t31-sut2.
1520 - IPMI IP: 10.30.50.44
1521 - Host IP: 10.30.51.47
1523 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1524 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1525 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1526 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1527 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1528 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1529 - ServerB13 [Server-Type-B2]:
1530 - testbedname: testbed31.
1531 - hostname: s13-t31-tg1.
1532 - IPMI IP: 10.30.50.45
1533 - Host IP: 10.30.51.48
1535 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1536 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1537 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1538 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1539 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1540 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1541 - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1542 - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1543 - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1544 - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1545 - ServerB14 [Server-Type-B1]:
1546 - testbedname: testbed32.
1547 - hostname: s14-t32-sut1.
1548 - IPMI IP: 10.30.50.55
1549 - Host IP: 10.30.51.58
1551 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1552 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1553 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1554 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1555 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1556 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1557 - ServerB15 [Server-Type-B1]:
1558 - testbedname: testbed32.
1559 - hostname: s15-t32-sut2.
1560 - IPMI IP: 10.30.50.56
1561 - Host IP: 10.30.51.59
1563 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1564 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1565 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1566 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1567 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1568 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1569 - ServerB16 [Server-Type-B2]:
1570 - testbedname: testbed32.
1571 - hostname: s16-t32-tg1.
1572 - IPMI IP: 10.30.50.57
1573 - Host IP: 10.30.51.60
1575 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1576 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1577 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1578 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1579 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1580 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1581 - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1582 - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1583 - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1584 - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1587 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1589 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1592 - ServerB22 [Server-Type-B5]:
1593 - testbedname: testbed35.
1594 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1595 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1596 - Host IP: 10.30.51.9
1598 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1599 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1601 - ServerB23 [Server-Type-B5]:
1602 - testbedname: testbed35.
1603 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1604 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1605 - Host IP: 10.30.51.10
1607 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1608 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1610 - ServerB24 [Server-Type-B5]:
1611 - testbedname: testbed35.
1612 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1613 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1614 - Host IP: 10.30.51.11
1616 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1617 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1621 #### 3-Node-Taishan Servers (3n-tsh) PROD
1623 Note: Server19 (TG) is shared between testbed33 & testbed211
1626 - SUT [Server-Type-E21]:
1627 - testbedname: testbed33.
1628 - hostname: s17-t33-sut1.
1629 - IPMI IP: 10.30.50.36
1630 - Host IP: 10.30.51.36
1632 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1633 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1634 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1635 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1636 - SUT [Server-Type-E21]:
1637 - testbedname: testbed33.
1638 - hostname: s18-t33-sut2.
1639 - IPMI IP: 10.30.50.37
1640 - Host IP: 10.30.51.37
1642 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1643 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1644 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1645 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1646 - TG [Server-Type-E31]:
1647 - testbedname: testbed33 and testbed211.
1648 - hostname: s19-t33t211-tg1.
1649 - IPMI IP: 10.30.50.46
1650 - Host IP: 10.30.51.49
1652 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1653 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1654 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1655 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1656 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1657 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1658 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1659 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1660 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1661 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1662 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1663 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1666 #### 3-Node-Altra Servers (3n-alt) TBD
1668 Note: Server64 (TG) is shared between testbed34 & testbed36
1671 - SUT [Server-Type-E23]:
1672 - testbedname: testbed34.
1673 - hostname: s62-t34-sut1.
1674 - IPMI IP: 10.30.50.72
1675 - Host IP: 10.30.51.72
1677 - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1678 - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1679 - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1680 - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1681 - SUT [Server-Type-E23]:
1682 - testbedname: testbed34.
1683 - hostname: s63-t34-sut2.
1684 - IPMI IP: 10.30.50.73
1685 - Host IP: 10.30.51.73
1687 - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1688 - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1689 - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1690 - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1691 - TG [Server-Type-F4]:
1692 - testbedname: testbed34.
1693 - hostname: s64-t34t36-tg1.
1694 - IPMI IP: 10.30.50.74
1695 - Host IP: 10.30.51.74
1697 - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1698 - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1701 #### 3-Node-Denverton Servers (3n-dnv) PROD
1704 - ServerB30 [Server-Type-B10]:
1705 - testbednames: testbed35.
1706 - hostname: s30-t35-sut1.
1707 - IPMI IP: 10.30.55.12
1708 - Host IP: 10.32.8.12
1710 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1711 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1712 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1713 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1714 - ServerB31 [Server-Type-B10]:
1715 - testbednames: testbed35.
1716 - hostname: s31-t35-sut2.
1717 - IPMI IP: 10.30.55.13
1718 - Host IP: 10.32.8.13
1720 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1721 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1722 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1723 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1726 #### 3-Node-Icelake Servers (3n-icx) TBD
1729 - ServerF1 [Server-Type-F1]:
1730 - testbedname: testbed37.
1731 - hostname: s65-t37-sut1.
1732 - IPMI IP: 10.30.50.75
1733 - Host IP: 10.30.51.75
1735 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1736 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1737 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1738 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1739 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1740 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1741 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1742 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1743 - ServerF1 [Server-Type-F1]:
1744 - testbedname: testbed37.
1745 - hostname: s66-t37-sut2.
1746 - IPMI IP: 10.30.50.76
1747 - Host IP: 10.30.51.76
1749 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1750 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1751 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1752 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1753 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1754 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1755 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1756 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1757 - ServerF3 [Server-Type-F3]:
1758 - testbedname: testbed37.
1759 - hostname: s67-t37-tg1.
1760 - IPMI IP: 10.30.50.77
1761 - Host IP: 10.30.51.77
1763 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1764 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1765 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1766 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1767 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1768 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1769 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1770 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1771 - ServerF1 [Server-Type-F1]:
1772 - testbedname: testbed38.
1773 - hostname: s68-t38-sut1.
1774 - IPMI IP: 10.30.50.78
1775 - Host IP: 10.30.51.78
1777 - s68-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1778 - s68-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1779 - s68-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1780 - s68-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1781 - s68-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1782 - s68-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1783 - s68-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1784 - s68-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1785 - ServerF1 [Server-Type-F1]:
1786 - testbedname: testbed38.
1787 - hostname: s69-t38-sut2.
1788 - IPMI IP: 10.30.50.79
1789 - Host IP: 10.30.51.79
1791 - s69-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1792 - s69-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1793 - s69-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1794 - s69-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1795 - s69-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1796 - s69-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1797 - s69-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1798 - s69-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1799 - ServerF3 [Server-Type-F3]:
1800 - testbedname: testbed38.
1801 - hostname: s70-t38-tg1.
1802 - IPMI IP: 10.30.50.80
1803 - Host IP: 10.30.51.80
1805 - s70-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1806 - s70-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1807 - s70-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1808 - s70-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1809 - s70-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1810 - s70-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1811 - s70-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1812 - s70-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1815 ### Per Testbed Wiring
1817 #### 1-Node-Skylake Wiring (1n-skx) PROD
1821 - ring1 10GE-ports x710-4p10GE:
1822 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1823 - ring2 10GE-ports x710-4p10GE:
1824 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1825 - ring3 10GE-ports x710-4p10GE:
1826 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1827 - ring4 10GE-ports x710-4p10GE:
1828 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1829 - ring5 100GE-ports e810-2p100GE:
1830 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1831 - ring6 100GE-ports e810-2p100GE:
1832 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1834 - ring1 10GE-ports x710-4p10GE:
1835 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1836 - ring2 10GE-ports x710-4p10GE:
1837 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1838 - ring3 10GE-ports x710-4p10GE:
1839 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1840 - ring4 10GE-ports x710-4p10GE:
1841 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1842 - ring5 100GE-ports e810-2p100GE:
1843 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1844 - ring6 100GE-ports e810-2p100GE:
1845 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1848 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1852 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1853 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1854 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1855 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1856 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1857 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1858 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1859 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1862 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1863 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1864 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1865 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1866 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1867 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1868 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1869 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1872 #### 2-Node-Skylake Wiring (2n-skx) PROD
1876 - ring1 10GE-ports x710-4p10GE on SUT:
1877 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1878 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1879 - ring2 10GE-ports x710-4p10GE on SUT:
1880 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1881 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1882 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1883 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1884 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1885 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1886 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1887 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1889 - ring1 10GE-ports x710-4p10GE on SUT:
1890 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1891 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1892 - ring2 10GE-ports x710-4p10GE on SUT:
1893 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1894 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1895 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1896 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1897 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1898 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1899 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1900 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1902 - ring1 10GE-ports x710-4p10GE on SUT:
1903 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1904 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1905 - ring2 10GE-ports x710-4p10GE on SUT:
1906 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1907 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1908 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1909 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1910 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1911 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1912 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1913 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1915 - ring1 10GE-ports x710-4p10GE on SUT:
1916 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1917 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1918 - ring2 10GE-ports x710-4p10GE on SUT:
1919 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1920 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1921 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1922 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1923 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1924 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1925 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1926 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1929 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1933 - ring1 10GE-ports x553 copper port on SUT:
1934 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1935 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1936 - ring2 10GE-ports x553 fiber port on SUT:
1937 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1938 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1941 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1945 - link1 10GE-port x710-4p10GE on SUT:
1946 - t25-tg1-p1 to t25-sut1-c2/p1.
1947 - link2 10GE-port x710-4p10GE on SUT:
1948 - t25-tg1-p2 to t25-sut1-c2/p2.
1949 - link3 10GE-port x710-4p10GE on SUT:
1950 - t25-tg1-p3 to t25-sut1-c2/p3.
1951 - link4 10GE-port x710-4p10GE on SUT:
1952 - t25-tg1-p4 to t25-sut1-c2/p4.
1955 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1959 - ring1 10GE-ports x710-4p10GE on SUT:
1960 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1961 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1962 - ring2 10GE-ports x710-4p10GE on SUT:
1963 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1964 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1965 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1966 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1967 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1968 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1969 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1970 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1971 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1972 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1973 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1974 - ring6 100GE-ports e810-2p100GE on TG:
1975 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1976 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1978 - ring1 10GE-ports x710-4p10GE on SUT:
1979 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1980 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1981 - ring2 10GE-ports x710-4p10GE on SUT:
1982 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1983 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1984 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1985 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1986 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1987 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1988 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1989 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1990 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1991 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1992 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1993 - ring6 100GE-ports e810-2p100GE on TG:
1994 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1995 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1997 - ring1 10GE-ports x710-4p10GE on SUT:
1998 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1999 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
2000 - ring2 10GE-ports x710-4p10GE on SUT:
2001 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
2002 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
2003 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2004 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
2005 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
2006 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2007 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
2008 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
2009 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2010 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
2011 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
2014 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
2018 - ring1 10GE-ports x710-4p10GE on SUT:
2019 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
2020 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
2021 - ring2 10GE-ports x710-4p10GE on SUT:
2022 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
2023 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
2024 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2025 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
2026 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
2027 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2028 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
2029 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
2032 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
2036 - ring1 10GE-ports x520-2p10GE on SUTs:
2037 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
2038 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
2041 #### 2-Node-Icelake Wiring (2n-icx) TBD
2045 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2046 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
2047 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
2048 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2049 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
2050 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
2051 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
2052 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
2053 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2054 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
2055 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
2056 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2057 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
2058 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
2060 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2061 - s74-t213-tg1-c2/p1 to s73-t213-sut1-c2/p1.
2062 - s73-t213-sut1-c2/p2 to s74-t213-tg1-c2/p2.
2063 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2064 - s74-t213-tg1-c4/p1 to s73-t213-sut1-c4/p1.
2065 - s73-t213-sut1-c4/p2 to s74-t213-tg1-c4/p2.
2066 - s74-t213-tg1-c4/p3 to s73-t213-sut1-c4/p3.
2067 - s73-t213-sut1-c4/p4 to s74-t213-tg1-c4/p4.
2068 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2069 - s74-t213-tg1-c9/p1 to s73-t213-sut1-c9/p1.
2070 - s73-t213-sut1-c9/p2 to s74-t213-tg1-c9/p2.
2071 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2072 - s74-t213-tg1-c6/p1 to s74-t213-tg1-c6/p2.
2073 - s74-t213-tg1-c6/p2 to s74-t213-tg1-c6/p1.
2075 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2076 - s76-t214-tg1-c2/p1 to s75-t214-sut1-c2/p1.
2077 - s75-t214-sut1-c2/p2 to s76-t214-tg1-c2/p2.
2078 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2079 - s76-t214-tg1-c4/p1 to s75-t214-sut1-c4/p1.
2080 - s75-t214-sut1-c4/p2 to s76-t214-tg1-c4/p2.
2081 - s76-t214-tg1-c4/p3 to s75-t214-sut1-c4/p3.
2082 - s75-t214-sut1-c4/p4 to s76-t214-tg1-c4/p4.
2083 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2084 - s76-t214-tg1-c9/p1 to s75-t214-sut1-c9/p1.
2085 - s75-t214-sut1-c9/p2 to s76-t214-tg1-c9/p2.
2086 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2087 - s76-t214-tg1-c6/p1 to s76-t214-tg1-c6/p2.
2088 - s76-t214-tg1-c6/p2 to s76-t214-tg1-c6/p1.
2090 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2091 - s78-t215-tg1-c2/p1 to s77-t215-sut1-c2/p1.
2092 - s77-t215-sut1-c2/p2 to s78-t215-tg1-c2/p2.
2093 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2094 - s78-t215-tg1-c4/p1 to s77-t215-sut1-c4/p1.
2095 - s77-t215-sut1-c4/p2 to s78-t215-tg1-c4/p2.
2096 - s78-t215-tg1-c4/p3 to s77-t215-sut1-c4/p3.
2097 - s77-t215-sut1-c4/p4 to s78-t215-tg1-c4/p4.
2098 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2099 - s78-t215-tg1-c9/p1 to s77-t215-sut1-c9/p1.
2100 - s77-t215-sut1-c9/p2 to s78-t215-tg1-c9/p2.
2101 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2102 - s78-t215-tg1-c6/p1 to s78-t215-tg1-c6/p2.
2103 - s78-t215-tg1-c6/p2 to s78-t215-tg1-c6/p1.
2106 #### 3-Node-Skylake Wiring (3n-skx) PROD
2110 - ring1 10GE-ports x710-4p10GE on SUTs:
2111 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
2112 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
2113 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
2114 - ring2 10GE-ports x710-4p10GE on SUT:
2115 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
2116 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
2117 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
2118 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2119 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
2120 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
2121 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
2122 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2123 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
2124 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
2125 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
2126 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2127 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
2128 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
2130 - ring1 10GE-ports x710-4p10GE on SUTs:
2131 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
2132 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
2133 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
2134 - ring2 10GE-ports x710-4p10GE on SUT:
2135 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
2136 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
2137 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
2138 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2139 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
2140 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
2141 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
2142 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2143 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
2144 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
2145 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
2146 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2147 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
2148 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
2151 #### 3-Node-Rangeley Wiring (3n-rng) TODO
2157 #### 3-Node-Taishan Wiring (3n-tsh) PROD
2161 - ring1 10GE-ports x520-2p10GE on SUTs:
2162 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
2163 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
2164 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
2165 - ring2 25GE-ports cx4-2p25GE on SUTs:
2166 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
2167 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
2168 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
2171 #### 3-Node-Altra Wiring (3n-alt) TBD
2175 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
2176 - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
2177 - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
2178 - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
2179 - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
2180 - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
2181 - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
2182 - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
2185 #### 3-Node-Denverton Wiring (3n-dnv) PROD
2189 - ring1 10GE-ports x553 copper port on SUTs:
2190 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
2191 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
2192 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
2193 - ring2 10GE-ports x553 fiber port on SUTs:
2194 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
2195 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
2196 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
2199 #### 3-Node-Icelake Wiring (3n-icx) PROD
2203 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2204 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
2205 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
2206 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
2207 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2208 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
2209 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
2210 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
2211 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
2212 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
2213 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
2214 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2215 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
2216 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
2217 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
2219 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2220 - s70-t38-tg1-c2/p1 to s68-t38-sut1-c2/p1.
2221 - s68-t38-sut1-c2/p2 to s69-t38-sut2-c2/p2.
2222 - s69-t38-sut2-c2/p1 to s70-t38-tg1-c2/p2.
2223 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2224 - s70-t38-tg1-c4/p1 to s68-t38-sut1-c4/p1.
2225 - s68-t38-sut1-c4/p2 to s69-t38-sut2-c4/p2.
2226 - s69-t38-sut2-c4/p1 to s70-t38-tg1-c4/p2.
2227 - s70-t38-tg1-c4/p3 to s68-t38-sut1-c4/p3.
2228 - s68-t38-sut1-c4/p4 to s69-t38-sut2-c4/p4.
2229 - s69-t38-sut2-c4/p3 to s70-t38-tg1-c4/p4.
2230 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2231 - s70-t38-tg1-c9/p1 to s68-t38-sut1-c9/p1.
2232 - s68-t38-sut1-c9/p2 to s69-t38-sut2-c9/p2.
2233 - s69-t38-sut2-c9/p1 to s70-t38-tg1-c9/p2.
2241 1. Ixia PerfectStorm One Appliance
2243 - Chassis: PS10GE4NG.
2244 - Motherboard: SuperMicro X11DPG-QT.
2245 - Processors: Quad-Core, Intel Processor.
2246 - HW accelerators: FPGA offload.
2248 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
2249 - Physical Interfaces: 4 * 10GE SFP+.
2250 - Operating System: Native IxOS.
2256 1. Arm Cortex A-72 servers
2257 - 2 * ThunderX2 (VPP Device)
2258 - Chassis: GIGABYTE Rack Mount
2259 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
2260 - RAM Memory: 16* 16GB DIMM
2261 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
2262 - 1 * ThunderX2 (Performance)
2263 - Chassis: GIGABYTE Rack Mount
2264 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
2265 - RAM Memory: 4* 32GB RDIMM
2266 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
2267 - 2 * Huawei TaiShan 2280.
2268 - Chassis: Huawei TaiShan 2280.
2269 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
2270 - RAM Memory: 8* 16GB DDR4-2400MT/s.
2271 - Disks: 1* 4TB SATA HDD.
2279 ### Xeon and Atom Servers
2282 1. Intel Xeon servers:
2283 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
2284 - Chassis: SuperMicro SYS-7049GP-TRT.
2285 - Motherboard: SuperMicro X11DPG-QT.
2286 - Processors: 2* Intel Platinum 8180 2.5 GHz.
2287 - RAM Memory: 16* 16GB DDR4-2666MHz.
2288 - Disks: 2* 1.6TB 6G SATA SSD.
2289 2. Intel Atom servers with Rangely processors.
2290 - 3 * Netgate XG-2758-1u
2291 - Chassis: Netgate XG-2758-1u
2292 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
2293 - RAM Memory: 16GB ECC
2297 ### Network Interface Cards
2301 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
2302 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
2303 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
2305 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
2307 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
2309 - 4 * mcx556a-edat NICs (not on site yet, in transit)
2312 ### Pluggables and Cables
2318 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
2319 - 80 * 10G SR optic (generic, "Intel" compatible branded)
2325 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
2336 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable