1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
- 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
- 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
- 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
- 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
+ 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
+ 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
+ 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
+ 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
+ 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
+ 1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr)
+ 1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr)
1. [Server Management](#server-management)
- 1. [Requirements](#requirements)
1. [Addressing](#addressing)
- 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
- 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
1. [Server Specifications](#server-specifications)
1. [Server Types](#server-types)
1. [Naming Convention](#naming-convention)
1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
- 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
- 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
- 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
+ 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
+ 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
+ 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
+ 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
+ 1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod)
1. [Per Testbed Wiring](#per-testbed-wiring)
1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
- 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
- 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
- 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
- 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
+ 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
+ 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
-1. [Inventory](#inventory)
- 1. [Appliances](#appliances)
- 1. [Arm Servers](#arm-servers)
- 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
- 1. [Network Interface Cards](#network-interface-cards)
- 1. [Pluggables and Cables](#pluggables-and-cables)
- 1. [Other Parts](#other-parts)
+ 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
+ 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
+ 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
+ 1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod)
## Purpose
### Summary List
```
- #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
- 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0
- 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
- 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
- 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
- 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
- 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
- 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
- 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
- 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
-10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
-11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
-12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
-13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
-14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
- Totals: 25 31 15 4 19 1 2 3 3 2 7 2
+ #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
+ 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0
+ 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0
+ 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
+ 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0
+ 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0
+ 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0
+ 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0
+ 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0
+ 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0
+10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0
+11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
+12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
+13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
+13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
+ Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
```
### 1-Node-Skylake Xeon Intel (1n-skx)
### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
-Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
Used for FD.io VPP_Device functional driver tests.
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Denverton Atom Intel (2n-dnv)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
-TG (Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
-Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
-one TG (Server-Type-B12) connected in a 2-node circular topology
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
+one TG (Server-Type-E31) connected in a 2-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Haswell Xeon Intel (3n-hsw)
+### 2-Node-Icelake Xeon Intel (2n-icx)
-Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
-TG (Server-Type-A2) connected in a 3-node circular topology
+Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
+one TG (Server-Type-F2) connected in a 2-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Skylake Xeon Intel (3n-skx)
+### 3-Node-Rangeley Atom Testbeds
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 3-Node-TaiShan Arm Huawei (3n-tsh)
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
-TG (Server-Type-B12) connected in a 3-node circular topology
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
+TG (Server-Type-E31) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Rangeley Atom Testbeds
+### 3-Node-Altra Arm Ampere (3n-alt)
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
+Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-## Server Management
+### 3-Node-Icelake Xeon Intel (3n-icx)
-### Requirements
+Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
+TG (Server-Type-F3) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
-For management purposes, each server must have following two ports
-connected to the management network:
+### 3-Node-SnowRidge Atom Intel (3n-snr)
-```
-- 1GE IPMI port
- - IPMI - Intelligent Platform Management Interface.
- - Required for access to embedded server management with WebUI, CLI,
- SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
-- 1GE/10GE/40GE management port
- - hostOS management port for general system management.
-```
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
+
+One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and
+one TG (Server-Type-H2) connected in a 2-node physical topology
+with NUMA (socket) daisy chaining. For more detail see
+[Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
+Used for FD.io performance tests in a full system SUT setup with all PCIe
+Gen5 x16 lane slots populated with 2p200GbE NICs.
+
+### 2-Node-SapphireRapids Xeon Intel (2n-spr)
+
+Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
+one TG (Server-Type-H6) connected in a 2-node circular topology. For more
+detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
+Used for FD.io performance tests.
+
+## Server Management
### Addressing
To access these hosts, VPN connection is required.
-### LOM (IPMI) VLAN IP Addresses
-
-Name | Comment
------------- | -------
-10.30.50.0 | network
-10.30.51.1 | Router
-10.30.50.2 | LF Reserved
-10.30.50.3 | LF Reserved
-10.30.50.4 | LF Reserved
-10.30.50.5 | LF Reserved
-10.30.50.6 | LF Reserved
-10.30.50.7 | LF Reserved
-10.30.50.8 | LF Reserved
-10.30.50.9 | LF Reserved
-10.30.50.10 | LF Reserved
-10.30.50.11 | LF Reserved
-10.30.50.12 | LF Reserved
-10.30.50.13 | LF Reserved
-10.30.50.14 | LF Reserved
-10.30.50.15 | LF Reserved
-10.30.50.22 | s42-nomad
-10.30.50.24 | s43-nomad
-10.30.50.25 | s44-nomad
-10.30.50.26 | s45-nomad
-10.30.50.28 | s41-nomad
-10.30.50.29 | s39-nomad
-10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
-10.30.50.30 | s40-nomad
-10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
-10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
-10.30.50.36 | s17-t33-sut1
-10.30.50.37 | s18-t33-sut2
-10.30.50.38 | fdio-marvell-dev
-10.30.50.39 | s53-nomad
-10.30.50.40 | s54-nomad
-10.30.50.41 | s3-t21-sut1
-10.30.50.42 | s4-t21-tg1
-10.30.50.43 | s11-t31-sut1
-10.30.50.44 | s12-t31-sut2
-10.30.50.45 | s13-t31-tg1
-10.30.50.46 | s19-t33t34-tg1
-10.30.50.47 | s1-t11-sut1
-10.30.50.48 | s2-t12-sut1
-10.30.50.49 | s5-t22-sut1
-10.30.50.50 | s6-t22-tg1
-10.30.50.51 | s7-t23-sut1
-10.30.50.52 | s8-t23-tg1
-10.30.50.53 | s9-t24-sut1
-10.30.50.54 | s10-t24-tg1
-10.30.50.55 | s14-t32-sut1
-10.30.50.56 | s15-t32-sut2
-10.30.50.57 | s16-t32-tg1
-10.30.50.58 | s25-t25-sut1
-10.30.50.59 | s26-t25-tg1
-10.30.50.65 | s52-nomad
-10.30.50.66 | s51-nomad
-10.30.50.67 | s49-nomad
-10.30.50.68 | s50-nomad
-10.30.50.69 | s27-t34-sut1
-10.30.50.70 | s55-t36-sut1
-10.30.50.71 | s56-t37-sut1
-10.30.50.255 | Broadcast
-n/a | s20-t34-sut1
-n/a | s21-t34-sut2
-10.30.55.0 | network
-10.30.55.1 | Router
-10.30.55.10 | s28-t26t35-tg1
-10.30.55.11 | s29-t26-sut1
-10.30.55.12 | s30-t35-sut1
-10.30.55.13 | s31-t35-sut2
-10.30.55.14 | s46-nomad
-10.30.55.15 | s47-nomad
-10.30.55.16 | s48-nomad
-10.30.55.17 | s57-nomad
-10.30.55.18 | s33-t27-sut1
-10.30.55.19 | s34-t27-tg1
-10.30.55.20 | s35-t28-sut1
-10.30.55.21 | s36-t28-tg1
-10.30.55.22 | s37-t29-sut1
-10.30.55.23 | s38-t29-tg1
-10.30.55.24 | s60-t210-sut1
-10.30.55.25 | s61-t210-tg1
-10.30.55.255 | Broadcast
-
-### Management VLAN IP Addresses
-
-Name | Comment
-------------------------- | -------
-10.30.51.0 | network
-10.30.51.1 | Router
-10.30.51.2 | LF Reserved
-10.30.51.3 | LF Reserved
-10.30.51.4 | LF Reserved
-10.30.51.5 | LF Reserved
-10.30.51.6 | LF Reserved
-10.30.51.7 | LF Reserved
-10.30.51.8 | LF Reserved
-10.30.51.15 | LF Reserved
-10.30.51.22 | s42-nomad
-10.30.51.24 | s43-nomad
-10.30.51.25 | s44-nomad
-10.30.51.26 | s45-nomad
-10.30.51.28 | s41-nomad
-10.30.51.29 | s39-nomad
-10.30.51.30 | s40-nomad
-10.30.51.36 | s17-t33-sut1
-10.30.51.37 | s18-t33-sut2
-10.30.51.38 | fdio-marvell-dev
-10.30.51.39 | s53-nomad
-10.30.51.40 | s54-nomad
-10.30.51.44 | s3-t21-sut1
-10.30.51.45 | s4-t21-tg1
-10.30.51.46 | s11-t31-sut1
-10.30.51.47 | s12-t31-sut2
-10.30.51.48 | s13-t31-tg1
-10.30.51.49 | s19-t33t34-tg1
-10.30.51.50 | s1-t11-sut1
-10.30.51.51 | s2-t12-sut1
-10.30.51.52 | s5-t22-sut1
-10.30.51.53 | s6-t22-tg1
-10.30.51.54 | s7-t23-sut1
-10.30.51.55 | s8-t23-tg1
-10.30.51.56 | s9-t24-sut1
-10.30.51.57 | s10-t24-tg1
-10.30.51.58 | s14-t32-sut1
-10.30.51.59 | s15-t32-sut2
-10.30.51.60 | s16-t32-tg1
-10.30.51.61 | s25-t25-sut1
-10.30.51.62 | s26-t25-tg1
-10.30.51.65 | s52-nomad
-10.30.51.66 | s51-nomad
-10.30.51.67 | s49-nomad
-10.30.51.68 | s50-nomad
-10.30.51.69 | s27-t34-sut1
-10.30.51.70 | s55-t36-sut1
-10.30.51.71 | s56-t37-sut1
-10.30.51.72-10.30.51.254 | FREE
-10.30.51.255 | Broadcast
-10.32.8.0 | network
-10.32.8.1 | Router
-10.32.8.10 | s28-t26t35-tg1
-10.32.8.11 | s29-t26-sut1
-10.32.8.12 | s30-t35-sut1
-10.32.8.13 | s31-t35-sut2
-10.32.8.14 | s46-nomad
-10.32.8.15 | s47-nomad
-10.32.8.16 | s48-nomad
-10.32.8.17 | s57-nomad
-10.32.8.18 | s33-t27-sut1
-10.32.8.19 | s34-t27-tg1
-10.32.8.20 | s35-t28-sut1
-10.32.8.21 | s36-t28-tg1
-10.32.8.22 | s37-t29-sut1
-10.32.8.23 | s38-t29-tg1
-10.32.8.24 | s60-t210-sut1
-10.32.8.25 | s61-t210-tg1
-10.32.8.255 | Broadcast
-
## Server Specifications
### Server Types
FD.io CSIT lab contains following server types:
```
-1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
- - Quantity: 6 servers.
- - Physical connectivity:
- - CIMC and host management ports.
- - NIC ports connected in 3-node topologies.
- - Main HW configuration:
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699v3 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- - NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- - PCIe Slot1: empty.
- - PCIe Slot2: empty.
- - PCIe Slot3: empty.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- - PCIe Slot4: empty.
- - PCIe Slot5: empty.
- - PCIe Slot6: empty
- - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
-2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
- - Quantity: 3 servers.
- - Physical connectivity:
- - CIMC and host management ports.
- - NIC ports connected in 3-node topologies.
- - Main HW configuration:
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699v3 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- - NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- - PCIe Slot1: empty.
- - PCIe Slot2: empty.
- - PCIe Slot3: empty.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- - PCIe Slot4: empty.
- - PCIe Slot5: empty.
- - PCIe Slot6: empty
- - MLOM slot: empty.
-3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
- - Quantity: 3 servers.
- - Physical connectivity:
- - CIMC and host management ports.
- - no NIC ports, standalone setup.
- - Main HW configuration:
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699v3 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
- - NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- - no cards.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- - no cards.
- - MLOM slot: empty.
-4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
+1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
- Quantity: ---
- Physical connectivity:
- IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot2 18:00.xx: empty.
+ - PCIe Slot4 3b:00.xx: empty.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
- - Quantity: ---
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI(?) and host management ports.
- - NIC ports connected into 3-node topology.
- - Main HW configuration:
- - Chassis: Huawei TaiShan 2280.
- - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
- - RAM Memory: 8* 16GB DDR4-2400MT/s
- - Disks: 1* 4TB SATA HDD
- - NICs configuration:
- - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
- - Quantity: TBD based on testbed allocation.
- - Physical connectivity:
- - Management: serial Port (usb) for console
- - NIC ports connected into 2-node.
- - Main HW configuration:
- - Chassis: Netgate XG-2758-1u
- - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
- - RAM Memory: 16GB ECC
- - Disks: 150 GB
- - NICs configuration:
- - 2x 10Gb Intel 82599ES
- - 4x 1GB Intel I354
-8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- Quantity: 1.
- Physical connectivity:
- Host management interface: 10/100/1000-BaseT.
- Port-2: 10GE SFP+.
- Port-3: 10GE SFP+.
- Port-4: 10GE SFP+.
-10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- - Quantity: 1
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: Gigabyte R181-T90 1U
- - Motherboard: MT91-FS1
- - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - NICs configuration:
- - Numa0:
- - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
- - Numa1:
- - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
- - Quantity: 4
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-E300-9A
- - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
- - RAM Memory: 32GB ECC
- - Disks: 480 GB
- - NICs configuration:
- - 2x 10Gb Intel x553 fiber ports
- - 2x 10Gb Intel x553 copper ports
- - 4x 1GB Intel I350 ports
-13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- - Quantity: 2
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: GIGABYTE Rack Mount
- - Motherboard: MT91-FS4-00
- - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
- - RAM Memory: 16 * 16GB DIMM
- - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - NICs configuration:
- - Numa0:
- - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
- - Numa1:
- - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
- - Quantity: ---
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-
-15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
+ - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- - CIMC and host management ports.
+ - IPMI and host management ports.
- no NIC ports, standalone setup.
- Main HW configuration:
- Chassis: SuperMicro 1029P-WTRT.
- no cards.
- Numa1:
- no cards.
-19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
+11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: GIGABYTE Rack Mount
+ - Motherboard: MT91-FS4-00
+ - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
+ - RAM Memory: 16 * 16GB DIMM
+ - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
+ - Numa1:
+ - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI(?) and host management ports.
+ - NIC ports connected into 3-node topology.
+ - Main HW configuration:
+ - Chassis: Huawei TaiShan 2280.
+ - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
+ - RAM Memory: 8* 16GB DDR4-2400MT/s
+ - Disks: 1* 4TB SATA HDD
+ - NICs configuration:
+ - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
+ - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
+13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node topologies.
+ - Main HW configuration:
+ - Chassis: Gigabyte R181-T90 1U
+ - Motherboard: MT91-FS1
+ - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
+ - RAM Memory: 4* 32GB RDIMM
+ - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
+ - NICs configuration:
+ - Numa0:
+ - no cards
+ - Numa1:
+ - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
+14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node topologies.
+ - Main HW configuration:
+ - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+ - Motherboard: Mt.Jade Motherboard
+ - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+ - RAM Memory: 16* 8GB DDR4-3200MT/s
+ - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
+ - Numa1:
+ - no cards.
+15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - Main HW configuration:
+ - Chassis: Gigabyte R152-P30-00 1U
+ - Motherboard: MP32-AR1-00
+ - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+ - RAM Memory: 12* 16GB DDR4-3200MT/s
+ - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+ - Quantity: 8.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and/or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 d8:00.xx: empty.
+21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topology.
+ - Main HW configuration:
+ - Chassis: Intel JACOBSVILLE SDP.
+ - Motherboard: Intel JACOBSVILLE E63448-400.
+ - Processors: 1* Intel Atom P5362B 2.2 GHz.
+ - RAM Memory: 2* 16GB DDR4-2933.
+ - Disks: ?* ? SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, PCIe3.0 lane)
+ - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
+22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot11 d8:00.xx: empty.
+24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot11 d8:00.xx: empty.
+25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-numa-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
+26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
+27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+ - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot11 d8:00.xx: empty.
```
### Naming Convention
#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
```
-- SUT [Server-Type-B11]:
- - testbedname: testbed36
- - hostname: s55-t36-sut1
+- SUT [Server-Type-E11]:
+ - testbedname: testbed13
+ - hostname: s55-t13-sut1
- IPMI IP: 10.30.50.70
- Host IP: 10.30.51.70
- portnames:
- - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-- SUT [Server-Type-B11]:
- - testbedname: testbed37
- - hostname: s56-t37-sut1
+ - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+- SUT [Server-Type-E11]:
+ - testbedname: testbed14
+ - hostname: s56-t14-sut1
- IPMI IP: 10.30.50.71
- Host IP: 10.30.51.71
- portnames:
- - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
```
#### 1-Node-Cascadelake Servers (1n-clx) PROD
- s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-Skylake Servers (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
- - testbedname: testbed21.
- - hostname: s3-t21-sut1.
- - IPMI IP: 10.30.50.41
- - Host IP: 10.30.51.44
- - portnames:
- - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed21.
- - hostname: s4-t21-tg1.
- - IPMI IP: 10.30.50.42
- - Host IP: 10.30.51.45
- - portnames:
- - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed22.
- - hostname: s5-t22-sut1.
- - IPMI IP: 10.30.50.49
- - Host IP: 10.30.51.52
- - portnames:
- - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed22.
- - hostname: s6-t22-tg1.
- - IPMI IP: 10.30.50.50
- - Host IP: 10.30.51.53
- - portnames:
- - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed23.
- - hostname: s7-t23-sut1.
- - IPMI IP: 10.30.50.51
- - Host IP: 10.30.51.54
- - portnames:
- - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed23.
- - hostname: s8-t23-tg1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.55
- - portnames:
- - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed24.
- - hostname: s9-t24-sut1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.56
- - portnames:
- - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed24.
- - hostname: s10-t24-tg1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.57
- - portnames:
- - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 2-Node-Denverton Servers (2n-dnv) PROD
-
-Note: ServerB28 (TG) is shared between testbed26 & testbed35
-
-```
-- TG [Server-Type-B2]:
- - testbednames: testbed26 and testbed35.
- - hostname: s28-t26t35-tg1.
- - IPMI IP: 10.30.55.10
- - Host IP: 10.32.8.10
- - portnames:
- - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
- - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
- - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
- - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
- - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
- - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
- - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
- - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
-- SUT [Server-Type-B10]:
- - testbednames: testbed26.
- - hostname: s29-t26-sut1.
- - IPMI IP: 10.30.55.11
- - Host IP: 10.32.8.11
- - portnames:
- - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
- - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
- - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
- - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
-```
-
#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
```
- s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
```
#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
-Note: Server19 (TG) is shared between testbed33 & testbed34
+Note: Server19 (TG) is shared between testbed33 & testbed211
```
-- SUT [Server-Type-B9]:
- - testbedname: testbed34.
- - hostname: s27-t34-sut1.
+- SUT [Server-Type-E22]:
+ - testbedname: testbed211.
+ - hostname: s27-t211-sut1.
- IPMI IP: 10.30.50.69
- Host IP: 10.30.51.69
- portnames:
- - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
-- TG [Server-Type-B12]:
- - testbedname: testbed33 and testbed34.
- - hostname: s19-t33t34-tg1.
+ - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+- TG [Server-Type-E31]:
+ - testbedname: testbed33 and testbed211.
+ - hostname: s19-t33t211-tg1.
- IPMI IP: 10.30.50.46
- Host IP: 10.30.51.49
- portnames:
- - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 3-Node-Skylake Servers (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s11-t31-sut1.
- - IPMI IP: 10.30.50.43
- - Host IP: 10.30.51.46
+ - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 2-Node-Icelake Servers (2n-icx) PROD
+
+```
+- SUT [Server-Type-F1]:
+ - testbedname: testbed212.
+ - hostname: s71-t212-sut1.
+ - IPMI IP: 10.30.50.81
+ - Host IP: 10.30.51.81
- portnames:
- - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB12 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s12-t31-sut2.
- - IPMI IP: 10.30.50.44
- - Host IP: 10.30.51.47
+ - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed212.
+ - hostname: s72-t212-tg1.
+ - IPMI IP: 10.30.50.82
+ - Host IP: 10.30.51.82
- portnames:
- - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB13 [Server-Type-B2]:
- - testbedname: testbed31.
- - hostname: s13-t31-tg1.
- - IPMI IP: 10.30.50.45
- - Host IP: 10.30.51.48
+ - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed213.
+ - hostname: s83-t213-sut1.
+ - IPMI IP: 10.30.50.83
+ - Host IP: 10.30.51.83
- portnames:
- - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB14 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s14-t32-sut1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.58
+ - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed213.
+ - hostname: s84-t213-tg1.
+ - IPMI IP: 10.30.50.84
+ - Host IP: 10.30.51.84
- portnames:
- - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB15 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s15-t32-sut2.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.59
+ - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed214.
+ - hostname: s85-t214-sut1.
+ - IPMI IP: 10.30.50.85
+ - Host IP: 10.30.51.85
- portnames:
- - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB16 [Server-Type-B2]:
- - testbedname: testbed32.
- - hostname: s16-t32-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.60
+ - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed214.
+ - hostname: s86-t214-tg1.
+ - IPMI IP: 10.30.50.86
+ - Host IP: 10.30.51.86
- portnames:
- - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+ - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed215.
+ - hostname: s87-t215-sut1.
+ - IPMI IP: 10.30.50.87
+ - Host IP: 10.30.51.87
+ - portnames:
+ - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed215.
+ - hostname: s88-t215-tg1.
+ - IPMI IP: 10.30.50.88
+ - Host IP: 10.30.51.88
+ - portnames:
+ - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
#### 3-Node-Rangeley Servers (3n-rng) VERIFY
#### 3-Node-Taishan Servers (3n-tsh) PROD
-Note: Server19 (TG) is shared between testbed33 & testbed34
+Note: Server19 (TG) is shared between testbed33 & testbed211
```
-- SUT [Server-Type-B3]:
+- SUT [Server-Type-E21]:
- testbedname: testbed33.
- hostname: s17-t33-sut1.
- IPMI IP: 10.30.50.36
- s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- SUT [Server-Type-B3]:
+- SUT [Server-Type-E21]:
- testbedname: testbed33.
- hostname: s18-t33-sut2.
- IPMI IP: 10.30.50.37
- s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- TG [Server-Type-B12]:
- - testbedname: testbed33 and testbed34.
- - hostname: s19-t33t34-tg1.
+- TG [Server-Type-E31]:
+ - testbedname: testbed33 and testbed211.
+ - hostname: s19-t33t211-tg1.
- IPMI IP: 10.30.50.46
- Host IP: 10.30.51.49
- portnames:
- - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Denverton Servers (3n-dnv) PROD
+#### 3-Node-Altra Servers (3n-alt) PROD
```
-- ServerB30 [Server-Type-B10]:
- - testbednames: testbed35.
- - hostname: s30-t35-sut1.
- - IPMI IP: 10.30.55.12
- - Host IP: 10.32.8.12
+- SUT [Server-Type-E23]:
+ - testbedname: testbed34.
+ - hostname: s62-t34-sut1.
+ - IPMI IP: 10.30.50.72
+ - Host IP: 10.30.51.72
- portnames:
- - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
- - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
- - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
- - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
-- ServerB31 [Server-Type-B10]:
- - testbednames: testbed35.
- - hostname: s31-t35-sut2.
- - IPMI IP: 10.30.55.13
- - Host IP: 10.32.8.13
+ - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- SUT [Server-Type-E23]:
+ - testbedname: testbed34.
+ - hostname: s63-t34-sut2.
+ - IPMI IP: 10.30.50.73
+ - Host IP: 10.30.51.73
+ - portnames:
+ - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- TG [Server-Type-F4]:
+ - testbedname: testbed34.
+ - hostname: s64-t34-tg1.
+ - IPMI IP: 10.30.50.74
+ - Host IP: 10.30.51.74
+ - portnames:
+ - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-Icelake Servers (3n-icx) PROD
+
+```
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed37.
+ - hostname: s65-t37-sut1.
+ - IPMI IP: 10.30.50.75
+ - Host IP: 10.30.51.75
+ - portnames:
+ - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed37.
+ - hostname: s66-t37-sut2.
+ - IPMI IP: 10.30.50.76
+ - Host IP: 10.30.51.76
+ - portnames:
+ - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+ - testbedname: testbed37.
+ - hostname: s67-t37-tg1.
+ - IPMI IP: 10.30.50.77
+ - Host IP: 10.30.51.77
+ - portnames:
+ - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed38.
+ - hostname: s78-t38-sut1.
+ - IPMI IP: 10.30.50.78
+ - Host IP: 10.30.51.78
- portnames:
- - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
- - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
- - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
- - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
+ - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed38.
+ - hostname: s79-t38-sut2.
+ - IPMI IP: 10.30.50.79
+ - Host IP: 10.30.51.79
+ - portnames:
+ - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+ - testbedname: testbed38.
+ - hostname: s80-t38-tg1.
+ - IPMI IP: 10.30.50.80
+ - Host IP: 10.30.51.80
+ - portnames:
+ - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-SnowRidge Servers (3n-snr) PROD
+
+```
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s93-t39-sut1.
+ - IPMI IP: 10.30.50.93
+ - Host IP: 10.30.51.93
+ - portnames:
+ - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s94-t39-sut2.
+ - IPMI IP: 10.30.50.94
+ - Host IP: 10.30.51.94
+ - portnames:
+ - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+ - testbedname: testbed39.
+ - hostname: s89-t39t310-tg1.
+ - IPMI IP: 10.30.50.89
+ - Host IP: 10.30.51.89
+ - portnames:
+ - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+```
+
+#### 2-Node-SapphireRapids Servers (2n-spr) PROD
+
+```
+- SUT [Server-Type-H1]:
+ - testbedname: testbed21.
+ - hostname: s52-t21-sut1.
+ - IPMI IP: 10.30.50.52
+ - Host IP: 10.30.51.52
+ - portnames:
+ - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE.
+- TG [Server-Type-H2]:
+ - testbedname: testbed21.
+ - hostname: s53-t21-tg1.
+ - IPMI IP: 10.30.51.53
+ - Host IP: 10.30.50.53
+ - portnames:
+ - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
+- SUT [Server-Type-H3]:
+ - testbedname: testbed22.
+ - hostname: s54-t22-sut1.
+ - IPMI IP: 10.30.50.54
+ - Host IP: 10.30.51.54
+ - portnames:
+ - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H4]:
+ - testbedname: testbed22.
+ - hostname: s55-t22-tg1.
+ - IPMI IP: 10.30.51.55
+ - Host IP: 10.30.50.55
+ - portnames:
+ - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- SUT [Server-Type-H5]:
+ - testbedname: testbed23.
+ - hostname: s56-t23-sut1.
+ - IPMI IP: 10.30.50.56
+ - Host IP: 10.30.51.56
+ - portnames:
+ - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H6]:
+ - testbedname: testbed23.
+ - hostname: s57-t23-tg1.
+ - IPMI IP: 10.30.51.57
+ - Host IP: 10.30.50.57
+ - portnames:
+ - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+ - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+ - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
### Per Testbed Wiring
#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
```
-- testbed36:
+- testbed13:
- ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
+ - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
- ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
+ - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
- ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
+ - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
- ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
+ - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
-- testbed37:
+- testbed14:
- ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
+ - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
- ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
+ - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
- ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
+ - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
- ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
-```
-
-#### 1-Node-Cascadelake Wiring (1n-clx) PROD
-
-```
-- testbed14:
- - ring1 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
-```
-
-#### 2-Node-Skylake Wiring (2n-skx) PROD
-
-```
-- testbed21:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
- - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
- - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-- testbed22:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
- - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
- - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-- testbed23:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
- - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
- - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-- testbed24:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
- - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
- - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-```
-
-#### 2-Node-Denverton Wiring (2n-dnv) PROD
-
-```
-- testbed26:
- - ring1 10GE-ports x553 copper port on SUT:
- - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
- - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
- - ring2 10GE-ports x553 fiber port on SUT:
- - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
- - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
+ - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT:
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+ - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
- testbed28:
- ring1 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT:
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+ - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
- testbed29:
- ring1 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- - ring6 100GE-ports e810-2p100GE on SUT:
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
- s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
```
#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
```
-- testbed34:
+- testbed211:
- ring1 10GE-ports x520-2p10GE on SUTs:
- - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
- - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
-```
-
-#### 3-Node-Skylake Wiring (3n-skx) PROD
-
-```
-- testbed31:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
- - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
- - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
- - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
- - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
- - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
- - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
- - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
- - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
- - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
- - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
- - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
- - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
- - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
- - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
- - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
- - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
- - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
- - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
-#### 3-Node-Rangeley Wiring (3n-rng) TODO
+ - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
+ - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
+```
+
+#### 2-Node-Icelake Wiring (2n-icx) PROD
+
+```
+- testbed212:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
+ - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
+ - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
+ - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
+ - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
+ - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
+ - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
+- testbed213:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+ - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+ - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+ - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+ - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+ - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+ - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
+- testbed214:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+ - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+ - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+ - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+ - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+ - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+ - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
+- testbed215:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+ - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+ - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+ - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+ - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+ - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+ - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
+```
+
+#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
```
To be completed.
```
- testbed33:
- ring1 10GE-ports x520-2p10GE on SUTs:
- - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
+ - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
- s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
- - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
+ - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
- ring2 25GE-ports cx4-2p25GE on SUTs:
- - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
+ - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
- s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
- - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
-```
-
-#### 3-Node-Denverton Wiring (3n-dnv) PROD
-
-```
-- testbed35:
- - ring1 10GE-ports x553 copper port on SUTs:
- - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
- - s30-t35-sut1-p1 to s31-t35-sut2-p1.
- - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
- - ring2 10GE-ports x553 fiber port on SUTs:
- - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
- - s30-t35-sut1-p3 to s31-t35-sut2-p3.
- - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
+ - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
```
-## Inventory
+#### 3-Node-Altra Wiring (3n-alt) PROD
-### Appliances
-
-```
-1. Ixia PerfectStorm One Appliance
- - 1 * PS10GE4NG
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
```
-
-### Arm Servers
-
-```
-1. Arm Cortex A-72 servers
- - 2 * ThunderX2 (VPP Device)
- - Chassis: GIGABYTE Rack Mount
- - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
- - RAM Memory: 16* 16GB DIMM
- - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - 1 * ThunderX2 (Performance)
- - Chassis: GIGABYTE Rack Mount
- - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - 2 * Huawei TaiShan 2280.
- - Chassis: Huawei TaiShan 2280.
- - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
- - RAM Memory: 8* 16GB DDR4-2400MT/s.
- - Disks: 1* 4TB SATA HDD.
-```
-
-### Xeon and Atom Servers
-
-```
-1. Intel Xeon servers:
- - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
-2. Intel Atom servers with Rangely processors.
- - 3 * Netgate XG-2758-1u
- - Chassis: Netgate XG-2758-1u
- - Processors: 1* Rangely (Atom) C2758 2.4 GHz
- - RAM Memory: 16GB ECC
- - Disks: 150 GB
-```
-
-### Network Interface Cards
-
-```
-1. 10GE NICs
- - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
- - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
- - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
-2. 25GE NICs
- - 12 * Intel® Ethernet Network Adapter XXV710-DA2
-3. 40GE NICs
- - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
-4. 100GE NICs
- - 4 * mcx556a-edat NICs (not on site yet, in transit)
-```
-
-### Pluggables and Cables
-
-Pluggables:
-
-```
-1. 10GE SFP+
- - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
- - 80 * 10G SR optic (generic, "Intel" compatible branded)
-2. 25GE SFP28
- - None
-3. 40GE QSFP+
- - None
-4. 100GE
- - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+- testbed34:
+ - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
+ - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+ - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+ - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
```
-Standalone cables:
+#### 3-Node-Icelake Wiring (3n-icx) PROD
```
-1. 10GE
- - None
-2. 25GE
- - None
-3. 40GE QSFP+
- - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
-4. 100GE
- - None
-```
-
-### Other Parts
-
-None.
+- testbed37:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+ - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
+ - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
+ - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+ - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
+ - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
+ - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
+ - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
+ - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
+ - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+ - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
+ - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
+ - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
+- testbed38:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+ - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+ - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+ - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+ - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+ - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+ - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+ - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+ - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+ - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+ - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+ - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+ - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+
+```
+- testbed39:
+ - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+ - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+ - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+ - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+ - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+ - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+ - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
+```
+
+#### 2-Node-SapphireRapids Wiring (2n-spr) PROD
+
+```
+TBD
+```
\ No newline at end of file