New upstream version 18.11-rc1
[deb_dpdk.git] / doc / guides / nics / enic.rst
index 438a83d..746d891 100644 (file)
@@ -260,6 +260,12 @@ Generic Flow API is supported. The baseline support is:
   - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
   - In total, up to 64 bytes of mask is allowed across all headers
 
   - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
   - In total, up to 64 bytes of mask is allowed across all headers
 
+- **1400 and later series VICS with advanced filters enabled**
+
+  All the above plus:
+
+  - Action: count
+
 More features may be added in future firmware and new versions of the VIC.
 Please refer to the release notes.
 
 More features may be added in future firmware and new versions of the VIC.
 Please refer to the release notes.
 
@@ -345,6 +351,41 @@ suitable for others. Such applications may change the mode by setting
   applications such as OVS-DPDK performance benchmarks that utilize
   only the default VLAN and want to see only untagged packets.
 
   applications such as OVS-DPDK performance benchmarks that utilize
   only the default VLAN and want to see only untagged packets.
 
+
+Vectorized Rx Handler
+---------------------
+
+ENIC PMD includes a version of the receive handler that is vectorized using
+AVX2 SIMD instructions. It is meant for bulk, throughput oriented workloads
+where reducing cycles/packet in PMD is a priority. In order to use the
+vectorized handler, take the following steps.
+
+- Use a recent version of gcc, icc, or clang and build 64-bit DPDK. If
+  the compiler is known to support AVX2, DPDK build system
+  automatically compiles the vectorized handler. Otherwise, the
+  handler is not available.
+
+- Set ``devargs`` parameter ``enable-avx2-rx=1`` to explicitly request that
+  PMD consider the vectorized handler when selecting the receive handler.
+  For example::
+
+    -w 12:00.0,enable-avx2-rx=1
+
+  As the current implementation is intended for field trials, by default, the
+  vectorized handler is not considered (``enable-avx2-rx=0``).
+
+- Run on a UCS M4 or later server with CPUs that support AVX2.
+
+PMD selects the vectorized handler when the handler is compiled into
+the driver, the user requests its use via ``enable-avx2-rx=1``, CPU
+supports AVX2, and scatter Rx is not used. To verify that the
+vectorized handler is selected, enable debug logging
+(``--log-level=pmd,debug``) and check the following message.
+
+.. code-block:: console
+
+    enic_use_vector_rx_handler use the non-scatter avx2 Rx handler
+
 .. _enic_limitations:
 