Trending: Reorganization
[csit.git] / docs / lab / testbed_specifications.md
index 73138ec..bff6383 100644 (file)
@@ -1,13 +1,15 @@
 # FD.io CSIT Testbed Specifications
 
 # FD.io CSIT Testbed Specifications
 
-1. [FD.io CSIT Testbed Specifications](#fdio-csit-testbed-specifications)
+1. [Purpose](#purpose)
 1. [Testbeds Overview](#testbeds-overview)
    1. [Summary List](#summary-list)
    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
 1. [Testbeds Overview](#testbeds-overview)
    1. [Summary List](#summary-list)
    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
+   1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
+   1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
    1. [Addressing](#addressing)
    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
    1. [Addressing](#addressing)
    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
-1. [Server Type Specification](#server-type-specification)
-   1. [Server and Port Naming](#server-and-port-naming)
+1. [Server Specifications](#server-specifications)
+   1. [Server Types](#server-types)
+   1. [Naming Convention](#naming-convention)
 1. [Testbeds Configuration](#testbeds-configuration)
    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
 1. [Testbeds Configuration](#testbeds-configuration)
    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
-      1 [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
-      1 [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
-      1 [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
-      1 [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
-      1 [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
-      1 [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
-      1 [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
-      1 [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
-      1 [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
-      1 [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
+      1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
+      1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
+      1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
+      1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
+      1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
+      1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
+      1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
+      1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
+      1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
+      1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
+      1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
+      1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
    1. [Per Testbed Wiring](#per-testbed-wiring)
    1. [Per Testbed Wiring](#per-testbed-wiring)
-      1 [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
-      1 [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
-      1 [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
-      1 [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
-      1 [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
-      1 [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
-      1 [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
-      1 [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
-      1 [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
-      1 [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
+      1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
+      1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
+      1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
+      1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
+      1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
+      1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
+      1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
+      1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
+      1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
+      1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
+      1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
+      1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
 1. [Inventory](#inventory)
    1. [Appliances](#appliances)
    1. [Arm Servers](#arm-servers)
 1. [Inventory](#inventory)
    1. [Appliances](#appliances)
    1. [Arm Servers](#arm-servers)
@@ -51,7 +58,7 @@
    1. [Pluggables and Cables](#pluggables-and-cables)
    1. [Other Parts](#other-parts)
 
    1. [Pluggables and Cables](#pluggables-and-cables)
    1. [Other Parts](#other-parts)
 
-## FD.io CSIT Testbed Specifications
+## Purpose
 
 This note includes specification of the physical testbed infrastructure
 hosted by LFN FD.io CSIT project.
 
 This note includes specification of the physical testbed infrastructure
 hosted by LFN FD.io CSIT project.
@@ -62,74 +69,102 @@ hosted by LFN FD.io CSIT project.
 
 ```
  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
 
 ```
  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
- 1. 1-Node-Skylake     func   skx   na    2    2    0    0    2    0    0    0    0    0    0
- 2. 1-Node-Thunderx2   func   tx2   na    1    1    0    0    0    0    0    0    1    0    0
- 3. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
- 4. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
- 5. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
- 6. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
- 7. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
- 8. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
- 9. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
-10. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
-11. 1-Node-VIRL        func   hsw   ---   3    3    0    3    0    0    0    0    0    0    0
-                                 Totals: 17   26   14   12   19    1    2    1    1    2    2
+ 1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0
+ 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0
+ 3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0
+ 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0
+ 5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
+ 6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
+ 7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
+ 8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0
+ 9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
+10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
+11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
+12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
+13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
+14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0
+                                 Totals: 22   35   18   12   19    1    2    3    1    2    2
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
 
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
 
-Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
-ports connected back-to-back.
+Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
 Used for FD.io VPP_Device functional driver tests.
 
 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
 
 Used for FD.io VPP_Device functional driver tests.
 
 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
 
-Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
-ports connected back-to-back.
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
+### 1-Node-Cascadelake Xeon Intel (1n-clx)
+
+Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
+NIC ports connected back-to-back ([Server Types](#server-types)).
+
 Used for FD.io VPP_Device functional driver tests.
 
 ### 2-Node-Skylake Xeon Intel (2n-skx)
 
 Used for FD.io VPP_Device functional driver tests.
 
 ### 2-Node-Skylake Xeon Intel (2n-skx)
 
-Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
-(Type-B2 server) connected back-to-back.
+Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
+(Server-Type-B2) connected in a 2-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 2-Node-Denverton Atom Intel (2n-dnv)
 
 Used for FD.io performance tests.
 
 ### 2-Node-Denverton Atom Intel (2n-dnv)
 
-Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
-(Type-B2 server) connected back-to-back.
+Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
+TG (Server-Type-B2) connected in a 2-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
 
 Used for FD.io performance tests.
 
 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
 
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
+Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
+TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
+circular topology ([Server Types](#server-types)).
 Used for FD.io TCP/IP and HTTP performance tests.
 
 Used for FD.io TCP/IP and HTTP performance tests.
 
-### 3-Node-Haswell Xeon Intel (3n-skx)
+### 2-Node-Cascadelake Xeon Intel (2n-clx)
+
+Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
+one TG (Server-Type-C3) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-Haswell Xeon Intel (3n-hsw)
+
+Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
+TG (Server-Type-A2) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
 
 ### 3-Node-Skylake Xeon Intel (3n-skx)
 
 
 ### 3-Node-Skylake Xeon Intel (3n-skx)
 
-Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
-TG (Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
+TG (Server-Type-B2) connected in a 3-node circular topology.
 Used for FD.io performance tests.
 
 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
 
 Used for FD.io performance tests.
 
 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
 
-Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
-(Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
+TG (Server-Type-B2) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 3-Node-MACCHIATObin Arm Marvell
 
 Used for FD.io performance tests.
 
 ### 3-Node-MACCHIATObin Arm Marvell
 
-Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
-one TG (Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
+one TG (Server-Type-B2) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 3-Node-Rangeley Atom Testbeds
 
 Used for FD.io performance tests.
 
 ### 3-Node-Rangeley Atom Testbeds
 
-Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
-and one TG (Type-2 server) connected in full-mesh triangle.
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ## Server Management
 Used for FD.io performance tests.
 
 ## Server Management
@@ -142,16 +177,16 @@ connected to the management network:
 ```
 - 1GE IPMI port
   - IPMI - Intelligent Platform Management Interface.
 ```
 - 1GE IPMI port
   - IPMI - Intelligent Platform Management Interface.
-  - Required for access to embedded server management with WebUI, CLI, SNMPv3,
-    IPMIv2.0, for firmware (BIOS) and OS updates.
+  - Required for access to embedded server management with WebUI, CLI,
+    SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
 - 1GE/10GE/40GE management port
   - hostOS management port for general system management.
 ```
 
 ### Addressing
 
 - 1GE/10GE/40GE management port
   - hostOS management port for general system management.
 ```
 
 ### Addressing
 
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
-port, which are connected to two different VLANs.
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
+Management port, which are connected to two different VLANs.
 
 ```
 1. LOM (IPMI) VLAN:
 
 ```
 1. LOM (IPMI) VLAN:
@@ -224,7 +259,23 @@ Name         | Comment
 10.30.50.58  | s25-t25-sut1
 10.30.50.59  | s26-t25-tg1
 10.30.50.69  | s27-t13-sut
 10.30.50.58  | s25-t25-sut1
 10.30.50.59  | s26-t25-tg1
 10.30.50.69  | s27-t13-sut
+n/a          | s20-t34-sut1
+n/a          | s21-t34-sut2
+10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyUSB0
+10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyUSB1
+10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyUSB2
+10.30.55.10  | s28-t26t35-tg1
+10.30.55.11  | s29-t26-sut1
+10.30.55.12  | s30-t35-sut1
+10.30.55.13  | s31-t35-sut2
 10.30.50.255 | Broadcast
 10.30.50.255 | Broadcast
+10.30.55.17  | s32-t14-sut1
+10.30.55.18  | s33-t27-sut1
+10.30.55.19  | s34-t27-tg1
+10.30.55.20  | s35-t28-sut1
+10.30.55.21  | s36-t28-tg1
+10.30.55.22  | s37-t29-sut1
+10.30.55.23  | s38-t29-tg1
 
 ### Management VLAN IP Addresses
 
 
 ### Management VLAN IP Addresses
 
@@ -289,12 +340,25 @@ Name                      | Comment
 10.30.51.106-10.30.51.180 | VIRL2
 10.30.51.181-10.30.51.254 | VIRL3
 10.30.51.255              | Broadcast
 10.30.51.106-10.30.51.180 | VIRL2
 10.30.51.181-10.30.51.254 | VIRL3
 10.30.51.255              | Broadcast
-
-## Server Type Specification
+10.32.8.10                | s28-t26t35-tg1
+10.32.8.11                | s29-t26-sut1
+10.32.8.12                | s30-t35-sut1
+10.32.8.13                | s31-t35-sut2
+10.32.8.17                | s32-t14-sut1
+10.32.8.18                | s33-t27-sut1
+10.32.8.19                | s34-t27-tg1
+10.32.8.20                | s35-t28-sut1
+10.32.8.21                | s36-t28-tg1
+10.32.8.22                | s37-t29-sut1
+10.32.8.23                | s38-t29-tg1
+
+## Server Specifications
+
+### Server Types
 
 FD.io CSIT lab contains following server types:
 ```
 
 FD.io CSIT lab contains following server types:
 ```
-1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
+1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
     - Quantity: 6 servers.
     - Physical connectivity:
         - CIMC and host management ports.
     - Quantity: 6 servers.
     - Physical connectivity:
         - CIMC and host management ports.
@@ -314,7 +378,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot5: Intel NIC x710 2p10GE.
             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
             - PCIe Slot5: Intel NIC x710 2p10GE.
             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
-2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
+2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
     - Quantity: 3 servers.
     - Physical connectivity:
         - CIMC and host management ports.
     - Quantity: 3 servers.
     - Physical connectivity:
         - CIMC and host management ports.
@@ -334,7 +398,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot5: Intel NIC x710 2p10GE.
             - PCIe Slot6: Intel NIC x710 2p10GE.
         - MLOM slot: empty.
             - PCIe Slot5: Intel NIC x710 2p10GE.
             - PCIe Slot6: Intel NIC x710 2p10GE.
         - MLOM slot: empty.
-3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
+3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
     - Quantity: 3 servers.
     - Physical connectivity:
         - CIMC and host management ports.
     - Quantity: 3 servers.
     - Physical connectivity:
         - CIMC and host management ports.
@@ -350,7 +414,7 @@ FD.io CSIT lab contains following server types:
         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
             - no cards.
         - MLOM slot: empty.
         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
             - no cards.
         - MLOM slot: empty.
-4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
+4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
@@ -358,19 +422,19 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+            - PCIe Slot9 5e:00.xx: empty.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
+5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
@@ -378,19 +442,19 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+            - PCIe Slot9 5e:00.xx: empty.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
     - Quantity: 2
     - Physical connectivity:
         - IPMI(?) and host management ports.
     - Quantity: 2
     - Physical connectivity:
         - IPMI(?) and host management ports.
@@ -402,8 +466,8 @@ FD.io CSIT lab contains following server types:
         - Disks: 1* 4TB SATA HDD
     - NICs configuration:
         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
         - Disks: 1* 4TB SATA HDD
     - NICs configuration:
         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
-        - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
-4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
+        - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
+7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
     - Quantity: 3
     - Physical connectivity:
         - Host management ports.
     - Quantity: 3
     - Physical connectivity:
         - Host management ports.
@@ -415,7 +479,7 @@ FD.io CSIT lab contains following server types:
         - Disks: 1* 128GB(?) SATA SDD
     - NICs configuration:
         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
         - Disks: 1* 128GB(?) SATA SDD
     - NICs configuration:
         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
+8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
     - Quantity: TBD based on testbed allocation.
     - Physical connectivity:
         - Management: serial Port (usb) for console
     - Quantity: TBD based on testbed allocation.
     - Physical connectivity:
         - Management: serial Port (usb) for console
@@ -428,7 +492,7 @@ FD.io CSIT lab contains following server types:
     - NICs configuration:
         - 2x 10Gb Intel 82599ES
         - 4x 1GB Intel I354
     - NICs configuration:
         - 2x 10Gb Intel 82599ES
         - 4x 1GB Intel I354
-6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
     - Quantity: 2.
     - Physical connectivity:
         - IPMI and host management ports.
     - Quantity: 2.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -436,7 +500,7 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
@@ -448,7 +512,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
     - Quantity: 1.
     - Physical connectivity:
         - Host management interface: 10/100/1000-BaseT.
     - Quantity: 1.
     - Physical connectivity:
         - Host management interface: 10/100/1000-BaseT.
@@ -467,7 +531,7 @@ FD.io CSIT lab contains following server types:
         - Port-2: 10GE SFP+.
         - Port-3: 10GE SFP+.
         - Port-4: 10GE SFP+.
         - Port-2: 10GE SFP+.
         - Port-3: 10GE SFP+.
         - Port-4: 10GE SFP+.
-8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -475,7 +539,7 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
@@ -487,7 +551,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
@@ -504,7 +568,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot3 08:00.xx: XL710-QDA2.
         - Numa1:
             - PCIe Slot6 85:00.xx: XL710-QDA2.
             - PCIe Slot3 08:00.xx: XL710-QDA2.
         - Numa1:
             - PCIe Slot6 85:00.xx: XL710-QDA2.
-10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
+13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
     - Quantity: 4
     - Physical connectivity:
         - IPMI and host management ports.
     - Quantity: 4
     - Physical connectivity:
         - IPMI and host management ports.
@@ -518,9 +582,90 @@ FD.io CSIT lab contains following server types:
         - 2x 10Gb Intel x553 fiber ports
         - 2x 10Gb Intel x553 copper ports
         - 4x 1GB Intel I350 ports
         - 2x 10Gb Intel x553 fiber ports
         - 2x 10Gb Intel x553 copper ports
         - 4x 1GB Intel I350 ports
+
+14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 1-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Platinum 8280 2.7 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 2* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+            - PCIe Slot9 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+
+15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+    - Quantity: 3
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Gold 6252N 2.3 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 2* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+              - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Platinum 8280 2.7 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 2* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+            - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+              - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+
+17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - CIMC and host management ports.
+        - no NIC ports, standalone setup.
+    - Main HW configuration:
+        - Chassis: SuperMicro 1029P-WTRT.
+        - Motherboard: SuperMicro X11DDW-NT.
+        - Processors: 2* Intel Platinum 8280 2.7 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 4* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0:
+            - no cards.
+        - Numa1:
+            - no cards.
 ```
 
 ```
 
-### Server and Port Naming
+### Naming Convention
 
 Following naming convention is used within this page to specify physical
 connectivity and wiring across defined CSIT testbeds:
 
 Following naming convention is used within this page to specify physical
 connectivity and wiring across defined CSIT testbeds:
@@ -545,10 +690,10 @@ connectivity and wiring across defined CSIT testbeds:
 
 ### Per Testbed Server Allocation and Naming
 
 
 ### Per Testbed Server Allocation and Naming
 
-#### 1-Node-Skylake (1n-skx) PROD
+#### 1-Node-Skylake Servers (1n-skx) PROD
 
 ```
 
 ```
-- ServerB1 [Type-B6]:
+- SUT [Server-Type-B6]:
     - testbedname: testbed11.
     - hostname: s1-t11-sut1.
     - IPMI IP: 10.30.50.47
     - testbedname: testbed11.
     - hostname: s1-t11-sut1.
     - IPMI IP: 10.30.50.47
@@ -562,7 +707,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- ServerB2 [Type-B6]:
+- SUT [Server-Type-B6]:
     - testbedname: testbed12.
     - hostname: s2-t12-sut1.
     - IPMI IP: 10.30.50.48
     - testbedname: testbed12.
     - hostname: s2-t12-sut1.
     - IPMI IP: 10.30.50.48
@@ -578,10 +723,10 @@ connectivity and wiring across defined CSIT testbeds:
         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
 ```
 
         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 1-Node-Thunderx2 (1n-tx2) WIP
+#### 1-Node-Thunderx2 Servers (1n-tx2) WIP
 
 ```
 
 ```
-- ServerB17 [Type-B9]:
+- SUT [Server-Type-B9]:
     - testbedname: testbed13.
     - hostname: s27-t13-sut1.
     - IPMI IP: 10.30.50.69
     - testbedname: testbed13.
     - hostname: s27-t13-sut1.
     - IPMI IP: 10.30.50.69
@@ -595,10 +740,29 @@ connectivity and wiring across defined CSIT testbeds:
         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
 ```
 
         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
 ```
 
-#### 2-Node-Skylake (2n-skx) PROD
+#### 1-Node-Cascadelake Servers (1n-clx) SETUP
 
 ```
 
 ```
-- ServerB3 [Type-B1]:
+- SUT [Server-Type-C1]:
+    - testbedname: testbed11.
+    - hostname: s32-t14-sut1.
+    - IPMI IP: 10.30.55.17
+    - Host IP: 10.32.8.17
+    - portnames:
+        - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+        - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+        - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+        - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 2-Node-Skylake Servers (2n-skx) PROD
+
+```
+- SUT [Server-Type-B1]:
     - testbedname: testbed21.
     - hostname: s3-t21-sut1.
     - IPMI IP: 10.30.50.41
     - testbedname: testbed21.
     - hostname: s3-t21-sut1.
     - IPMI IP: 10.30.50.41
@@ -610,9 +774,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB4 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed21.
     - hostname: s4-t21-tg1.
     - IPMI IP: 10.30.50.42
     - testbedname: testbed21.
     - hostname: s4-t21-tg1.
     - IPMI IP: 10.30.50.42
@@ -624,9 +786,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB5 [Type-B1]:
+- SUT [Server-Type-B1]:
     - testbedname: testbed22.
     - hostname: s5-t22-sut1.
     - IPMI IP: 10.30.50.49
     - testbedname: testbed22.
     - hostname: s5-t22-sut1.
     - IPMI IP: 10.30.50.49
@@ -638,9 +798,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB6 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed22.
     - hostname: s6-t22-tg1.
     - IPMI IP: 10.30.50.50
     - testbedname: testbed22.
     - hostname: s6-t22-tg1.
     - IPMI IP: 10.30.50.50
@@ -652,9 +810,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB7 [Type-B1]:
+- SUT [Server-Type-B1]:
     - testbedname: testbed23.
     - hostname: s7-t23-sut1.
     - IPMI IP: 10.30.50.51
     - testbedname: testbed23.
     - hostname: s7-t23-sut1.
     - IPMI IP: 10.30.50.51
@@ -666,9 +822,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB8 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed23.
     - hostname: s8-t23-tg1.
     - IPMI IP: 10.30.50.52
     - testbedname: testbed23.
     - hostname: s8-t23-tg1.
     - IPMI IP: 10.30.50.52
@@ -680,9 +834,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB9 [Type-B1]:
+- SUT [Server-Type-B1]:
     - testbedname: testbed24.
     - hostname: s9-t24-sut1.
     - IPMI IP: 10.30.50.53
     - testbedname: testbed24.
     - hostname: s9-t24-sut1.
     - IPMI IP: 10.30.50.53
@@ -694,9 +846,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB10 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed24.
     - hostname: s10-t24-tg1.
     - IPMI IP: 10.30.50.54
     - testbedname: testbed24.
     - hostname: s10-t24-tg1.
     - IPMI IP: 10.30.50.54
@@ -708,20 +858,47 @@ connectivity and wiring across defined CSIT testbeds:
         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 ```
 
 ```
 
-#### 2-Node-Denverton (2n-dnv) TODO
+#### 2-Node-Denverton Servers (2n-dnv) WIP
+
+Note: ServerB28 (TG) is shared between testbed26 & testbed35
 
 ```
 
 ```
-To be completed.
+- TG [Server-Type-B2]:
+    - testbednames: testbed26 and testbed35.
+    - hostname: s28-t26t35-tg1.
+    - IPMI IP: 10.30.55.10
+    - Host IP: 10.32.8.10
+    - portnames:
+        - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
+        - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
+        - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
+        - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
+        - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
+        - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
+        - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
+        - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
+- SUT [Server-Type-B10]:
+    - testbednames: testbed26.
+    - hostname: s29-t26-sut1.
+    - IPMI IP: 10.30.55.11
+    - Host IP: 10.32.8.11
+    - portnames:
+        - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
+        - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
+        - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
+        - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
 ```
 
 ```
 
-#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
 
 ```
 
 ```
-- ServerB25 [Type-B8]:
+- SUT [Server-Type-B8]:
     - testbedname: testbed25.
     - hostname: s25-t25-sut1.
     - IPMI IP: 10.30.50.58
     - testbedname: testbed25.
     - hostname: s25-t25-sut1.
     - IPMI IP: 10.30.50.58
@@ -731,7 +908,7 @@ To be completed.
         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- ServerB26 [Type-B7]:
+- TG [Server-Type-B7]:
     - testbedname: testbed25.
     - hostname: s26-t25-tg1.
     - IPMI IP: 10.30.50.59
     - testbedname: testbed25.
     - hostname: s26-t25-tg1.
     - IPMI IP: 10.30.50.59
@@ -743,10 +920,99 @@ To be completed.
         - s26-t25-tg1-p4 - 10GE-port4.
 ```
 
         - s26-t25-tg1-p4 - 10GE-port4.
 ```
 
-#### 3-Node-Haswell (3n-hsw) PROD
+#### 2-Node-Cascadelake Servers (2n-clx) SETUP
 
 ```
 
 ```
- 1. Server1 of Type-1:
+- SUT [Server-Type-C2]:
+    - testbedname: testbed27.
+    - hostname: s33-t27-sut1.
+    - IPMI IP: 10.30.55.18
+    - Host IP: 10.32.8.18
+    - portnames:
+        - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+    - testbedname: testbed27.
+    - hostname: s34-t27-tg1.
+    - IPMI IP: 10.30.55.19
+    - Host IP: 10.32.8.19
+    - portnames:
+        - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+    - testbedname: testbed28.
+    - hostname: s35-t28-sut1.
+    - IPMI IP: 10.30.55.20
+    - Host IP: 10.32.8.20
+    - portnames:
+        - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+    - testbedname: testbed28.
+    - hostname: s36-t28-tg1.
+    - IPMI IP: 10.30.55.21
+    - Host IP: 10.32.8.21
+    - portnames:
+        - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+    - testbedname: testbed29.
+    - hostname: s37-t29-sut1.
+    - IPMI IP: 10.30.55.22
+    - Host IP: 10.32.8.22
+    - portnames:
+        - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+        - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+    - testbedname: testbed29.
+    - hostname: s38-t29-tg1.
+    - IPMI IP: 10.30.55.23
+    - Host IP: 10.32.8.23
+    - portnames:
+        - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+        - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+```
+
+#### 3-Node-Haswell Servers (3n-hsw) PROD
+
+```
+ 1. SUT [Server-Type-A1]:
     - testbedname: testbed1.
     - hostname: t1-sut1.
     - CIMC IP: 10.30.50.17
     - testbedname: testbed1.
     - hostname: t1-sut1.
     - CIMC IP: 10.30.50.17
@@ -762,7 +1028,7 @@ To be completed.
         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. Server2 of Type-1:
+ 2. SUT [Server-Type-A1]:
     - testbedname: testbed1.
     - hostname: t1-sut2.
     - CIMC IP: 10.30.50.18
     - testbedname: testbed1.
     - hostname: t1-sut2.
     - CIMC IP: 10.30.50.18
@@ -778,7 +1044,7 @@ To be completed.
         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. Server3 of Type-2:
+ 3. TG [Server-Type-A2]:
     - testbedname: testbed1.
     - hostname: t1-tg1.
     - CIMC IP: 10.30.50.16
     - testbedname: testbed1.
     - hostname: t1-tg1.
     - CIMC IP: 10.30.50.16
@@ -796,7 +1062,7 @@ To be completed.
         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. Server4 of Type-1:
+ 4. SUT [Server-Type-A1]:
     - testbedname: testbed2.
     - hostname: t2-sut1.
     - CIMC IP: 10.30.50.21
     - testbedname: testbed2.
     - hostname: t2-sut1.
     - CIMC IP: 10.30.50.21
@@ -812,7 +1078,7 @@ To be completed.
         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. Server5 of Type-1:
+ 5. SUT [Server-Type-A1]:
     - testbedname: testbed2.
     - hostname: t2-sut2.
     - CIMC IP: 10.30.50.22
     - testbedname: testbed2.
     - hostname: t2-sut2.
     - CIMC IP: 10.30.50.22
@@ -828,7 +1094,7 @@ To be completed.
         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. Server6 of Type-2:
+ 6. TG [Server-Type-A2]:
     - testbedname: testbed2.
     - hostname: t2-tg1.
     - CIMC IP: 10.30.50.20
     - testbedname: testbed2.
     - hostname: t2-tg1.
     - CIMC IP: 10.30.50.20
@@ -846,7 +1112,7 @@ To be completed.
         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. Server7 of Type-1:
+ 7. SUT [Server-Type-A1]:
     - testbedname: testbed3.
     - hostname: t3-sut1.
     - CIMC IP: 10.30.50.25
     - testbedname: testbed3.
     - hostname: t3-sut1.
     - CIMC IP: 10.30.50.25
@@ -862,7 +1128,7 @@ To be completed.
         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. Server8 of Type-1:
+ 8. SUT [Server-Type-A1]:
     - testbedname: testbed3.
     - hostname: t3-sut2.
     - CIMC IP: 10.30.50.26
     - testbedname: testbed3.
     - hostname: t3-sut2.
     - CIMC IP: 10.30.50.26
@@ -878,7 +1144,7 @@ To be completed.
         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. Server9 of Type-2:
+ 9. TG [Server-Type-A2]:
     - testbedname: testbed3.
     - hostname: t3-tg1.
     - CIMC IP: 10.30.50.24
     - testbedname: testbed3.
     - hostname: t3-tg1.
     - CIMC IP: 10.30.50.24
@@ -898,10 +1164,10 @@ To be completed.
         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
 ```
 
         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
 ```
 
-#### 3-Node-Skylake (3n-skx) PROD
+#### 3-Node-Skylake Servers (3n-skx) PROD
 
 ```
 
 ```
-- ServerB11 [Type-B1]:
+- ServerB11 [Server-Type-B1]:
     - testbedname: testbed31.
     - hostname: s11-t31-sut1.
     - IPMI IP: 10.30.50.43
     - testbedname: testbed31.
     - hostname: s11-t31-sut1.
     - IPMI IP: 10.30.50.43
@@ -915,7 +1181,7 @@ To be completed.
         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB12 [Type-B1]:
+- ServerB12 [Server-Type-B1]:
     - testbedname: testbed31.
     - hostname: s12-t31-sut2.
     - IPMI IP: 10.30.50.44
     - testbedname: testbed31.
     - hostname: s12-t31-sut2.
     - IPMI IP: 10.30.50.44
@@ -929,7 +1195,7 @@ To be completed.
         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB13 [Type-B2]:
+- ServerB13 [Server-Type-B2]:
     - testbedname: testbed31.
     - hostname: s13-t31-tg1.
     - IPMI IP: 10.30.50.45
     - testbedname: testbed31.
     - hostname: s13-t31-tg1.
     - IPMI IP: 10.30.50.45
@@ -943,7 +1209,7 @@ To be completed.
         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB14 [Type-B1]:
+- ServerB14 [Server-Type-B1]:
     - testbedname: testbed32.
     - hostname: s14-t32-sut1.
     - IPMI IP: 10.30.50.55
     - testbedname: testbed32.
     - hostname: s14-t32-sut1.
     - IPMI IP: 10.30.50.55
@@ -957,7 +1223,7 @@ To be completed.
         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB15 [Type-B1]:
+- ServerB15 [Server-Type-B1]:
     - testbedname: testbed32.
     - hostname: s15-t32-sut2.
     - IPMI IP: 10.30.50.56
     - testbedname: testbed32.
     - hostname: s15-t32-sut2.
     - IPMI IP: 10.30.50.56
@@ -971,7 +1237,7 @@ To be completed.
         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB16 [Type-B2]:
+- ServerB16 [Server-Type-B2]:
     - testbedname: testbed32.
     - hostname: s16-t32-tg1.
     - IPMI IP: 10.30.50.57
     - testbedname: testbed32.
     - hostname: s16-t32-tg1.
     - IPMI IP: 10.30.50.57
@@ -987,14 +1253,12 @@ To be completed.
         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 ```
 
         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 ```
 
-Note: ServerB19 (TG) is shared between testbed33 & testbed34
-
-#### 3-Node-Rangeley (3n-rng) VERIFY
+#### 3-Node-Rangeley Servers (3n-rng) VERIFY
 
 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
 
 ```
 
 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
 
 ```
-- ServerB22 [Type-B5]:
+- ServerB22 [Server-Type-B5]:
     - testbedname: testbed35.
     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
     - testbedname: testbed35.
     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
@@ -1003,7 +1267,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
     - 1GB ports (tbd)
         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
     - 1GB ports (tbd)
-- ServerB23 [Type-B5]:
+- ServerB23 [Server-Type-B5]:
     - testbedname: testbed35.
     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
     - testbedname: testbed35.
     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
@@ -1012,7 +1276,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
     - 1GB ports (tbd)
         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
     - 1GB ports (tbd)
-- ServerB24 [Type-B5]:
+- ServerB24 [Server-Type-B5]:
     - testbedname: testbed35.
     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
     - testbedname: testbed35.
     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
@@ -1023,30 +1287,32 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
     - 1GB ports (tbd)
 ```
 
     - 1GB ports (tbd)
 ```
 
-#### 3-Node-Taishan (3n-tsh) WIP
+#### 3-Node-Taishan Servers (3n-tsh) WIP
+
+Note: ServerB19 (TG) is shared between testbed33 & testbed34
 
 ```
 
 ```
-- ServerB17 [Type-B3]:
+- ServerB17 [Server-Type-B3]:
     - testbedname: testbed33.
     - hostname: s17-t33-sut1.
     - IPMI IP: 10.30.50.36
     - Host IP: 10.30.51.36
     - portnames:
     - testbedname: testbed33.
     - hostname: s17-t33-sut1.
     - IPMI IP: 10.30.50.36
     - Host IP: 10.30.51.36
     - portnames:
-        - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
-        - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
+        - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
+        - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB18 [Type-B3]:
+- ServerB18 [Server-Type-B3]:
     - testbedname: testbed33.
     - hostname: s18-t33-sut2.
     - IPMI IP: 10.30.50.37
     - Host IP: 10.30.51.37
     - portnames:
     - testbedname: testbed33.
     - hostname: s18-t33-sut2.
     - IPMI IP: 10.30.50.37
     - Host IP: 10.30.51.37
     - portnames:
-        - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
-        - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
+        - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
+        - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB19 [Type-B2]:
+- ServerB19 [Server-Type-B2]:
     - testbednames: testbed33 and testbed34.
     - hostname: s19-t33t34-tg1.
     - IPMI IP: 10.30.50.46
     - testbednames: testbed33 and testbed34.
     - hostname: s19-t33t34-tg1.
     - IPMI IP: 10.30.50.46
@@ -1062,7 +1328,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB20 [Type-B4]:
+- ServerB20 [Server-Type-B4]:
     - testbedname: testbed34.
     - hostname: s20-t34-sut1.
     - IPMI IP: N/A
     - testbedname: testbed34.
     - hostname: s20-t34-sut1.
     - IPMI IP: N/A
@@ -1070,7 +1336,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
     - portnames:
         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
     - portnames:
         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
-- ServerB21 [Type-B4]:
+- ServerB21 [Server-Type-B4]:
     - testbedname: testbed34.
     - hostname: s21-t34-sut2.
     - IPMI IP: N/A
     - testbedname: testbed34.
     - hostname: s21-t34-sut2.
     - IPMI IP: N/A
@@ -1080,7 +1346,32 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
 ```
 
         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
 ```
 
-#### 3-Node-Mcbin (3n-mcb) TODO
+#### 3-Node-Denverton Servers (3n-dnv) WIP
+
+```
+- ServerB30 [Server-Type-B10]:
+    - testbednames: testbed35.
+    - hostname: s30-t35-sut1.
+    - IPMI IP: 10.30.55.12
+    - Host IP: 10.32.8.12
+    - portnames:
+        - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
+        - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
+        - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
+        - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
+- ServerB31 [Server-Type-B10]:
+    - testbednames: testbed35.
+    - hostname: s31-t35-sut2.
+    - IPMI IP: 10.30.55.13
+    - Host IP: 10.32.8.13
+    - portnames:
+        - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
+        - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
+        - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
+        - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
+```
+
+#### 3-Node-Mcbin Servers (3n-mcb) TODO
 
 ```
 To be completed.
 
 ```
 To be completed.
@@ -1088,7 +1379,7 @@ To be completed.
 
 ### Per Testbed Wiring
 
 
 ### Per Testbed Wiring
 
-#### 1-Node-Skylake (1n-skx) PROD
+#### 1-Node-Skylake Wiring (1n-skx) PROD
 
 ```
 - testbed11:
 
 ```
 - testbed11:
@@ -1111,7 +1402,7 @@ To be completed.
         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
 ```
 
         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
 ```
 
-#### 1-Node-Thunderx2 (1n-tx2) WIP
+#### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
 
 ```
 - testbed13:
 
 ```
 - testbed13:
@@ -1123,7 +1414,21 @@ To be completed.
         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
 ```
 
         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
 ```
 
-#### 2-Node-Skylake (2n-skx) PROD
+#### 1-Node-Cascadelake Wiring (1n-clx) SETUP
+
+```
+- testbed14:
+    - ring1 10GE-ports x710-4p10GE:
+        - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
+    - ring2 10GE-ports x710-4p10GE:
+        - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
+    - ring3 10GE-ports x710-4p10GE:
+        - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
+    - ring4 10GE-ports x710-4p10GE:
+        - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
+```
+
+#### 2-Node-Skylake Wiring (2n-skx) PROD
 
 ```
 - testbed21:
 
 ```
 - testbed21:
@@ -1136,12 +1441,6 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
-        - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
-        - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
 - testbed22:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
 - testbed22:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
@@ -1152,12 +1451,6 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
-        - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
-        - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
 - testbed23:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
 - testbed23:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
@@ -1168,12 +1461,6 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
-        - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
-        - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
 - testbed24:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
 - testbed24:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
@@ -1184,21 +1471,21 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
-        - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
-        - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
 ```
 
 ```
 
-#### 2-Node-Denverton (2n-dnv) TODO
+#### 2-Node-Denverton Wiring (2n-dnv) WIP
 
 ```
 
 ```
-To be completed.
+- testbed26:
+    - ring1 10GE-ports x553 copper port on SUT:
+        - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
+        - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
+    - ring2 10GE-ports x553 fiber port on SUT:
+        - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
+        - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
 ```
 
 ```
 
-#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
 
 ```
 - testbed25:
 
 ```
 - testbed25:
@@ -1212,7 +1499,51 @@ To be completed.
         - t25-tg1-p4 to t25-sut1-c2/p4.
 ```
 
         - t25-tg1-p4 to t25-sut1-c2/p4.
 ```
 
-#### 3-Node-Haswell (3n-hsw) PROD
+#### 2-Node-Cascadelake Wiring (2n-clx) SETUP
+
+```
+- testbed27:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
+        - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
+        - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
+        - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
+    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
+        - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
+- testbed28:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
+        - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
+        - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
+        - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
+    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
+        - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
+- testbed29:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
+        - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
+        - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
+        - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
+    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
+        - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
+```
+
+#### 3-Node-Haswell Wiring (3n-hsw) PROD
 
 ```
  1. testbed1:
 
 ```
  1. testbed1:
@@ -1288,7 +1619,7 @@ To be completed.
         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
 ```
 
         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
 ```
 
-#### 3-Node-Skylake (3n-skx) PROD
+#### 3-Node-Skylake Wiring (3n-skx) PROD
 
 ```
 - testbed31:
 
 ```
 - testbed31:
@@ -1333,17 +1664,17 @@ To be completed.
         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
 ```
 
         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
 ```
 
-#### 3-Node-Rangeley (3n-rng) TODO
+#### 3-Node-Rangeley Wiring (3n-rng) TODO
 
 ```
 To be completed.
 ```
 
 
 ```
 To be completed.
 ```
 
-#### 3-Node-Taishan (3n-tsh) WIP
+#### 3-Node-Taishan Wiring (3n-tsh) WIP
 
 ```
 - testbed33:
 
 ```
 - testbed33:
-    - ring1 10GE-ports 82599-2p10GE on SUTs:
+    - ring1 10GE-ports x520-2p10GE on SUTs:
         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
@@ -1353,7 +1684,7 @@ To be completed.
         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
 ```
 
         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
 ```
 
-#### 3-Node-Mcbin (3n-mcb) WIP
+#### 3-Node-Mcbin Wiring (3n-mcb) WIP
 
 ```
 - testbed34:
 
 ```
 - testbed34:
@@ -1363,6 +1694,20 @@ To be completed.
         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
 ```
 
         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
 ```
 
+#### 3-Node-Denverton Wiring (3n-dnv) WIP
+
+```
+- testbed35:
+    - ring1 10GE-ports x553 copper port on SUTs:
+        - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
+        - s30-t35-sut1-p1 to s31-t35-sut2-p1.
+        - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
+    - ring2 10GE-ports x553 fiber port on SUTs:
+        - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
+        - s30-t35-sut1-p3 to s31-t35-sut2-p3.
+        - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
+```
+
 ## Inventory
 
 ### Appliances
 ## Inventory
 
 ### Appliances
@@ -1408,7 +1753,7 @@ To be completed.
     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
 2. Intel Atom servers with Rangely processors.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
 2. Intel Atom servers with Rangely processors.