Report: Add NAT44 tests
[csit.git]
/
docs
/
report
/
introduction
/
methodology_nfv_service_density.rst
diff --git
a/docs/report/introduction/methodology_nfv_service_density.rst
b/docs/report/introduction/methodology_nfv_service_density.rst
index
23bdac9
..
c5407b5
100644
(file)
--- a/
docs/report/introduction/methodology_nfv_service_density.rst
+++ b/
docs/report/introduction/methodology_nfv_service_density.rst
@@
-16,18
+16,16
@@
service chain forwarding context(s). In order to provide a most complete
picture, each network topology and service configuration is tested in
different service density setups by varying two parameters:
picture, each network topology and service configuration is tested in
different service density setups by varying two parameters:
-- Number of service instances (e.g. 1,
2,4..
10).
-- Number of NFs per service instance (e.g. 1,
2,4..
10).
+- Number of service instances (e.g. 1,
2, 4, 6, 8,
10).
+- Number of NFs per service instance (e.g. 1,
2, 4, 6, 8,
10).
-The initial implementation of NFV service density tests in
-
|csit-release| is using two NF
applications:
+Implementation of NFV service density tests in |csit-release| is using two NF
+applications:
- VNF: VPP of the same version as vswitch running in KVM VM, configured with /8
IPv4 prefix routing.
- CNF: VPP of the same version as vswitch running in Docker Container,
- VNF: VPP of the same version as vswitch running in KVM VM, configured with /8
IPv4 prefix routing.
- CNF: VPP of the same version as vswitch running in Docker Container,
- configured with /8 IPv4 prefix routing. VPP got chosen as a fast IPv4 NF
- application that supports required memif interface (L3fwd does not). This is
- similar to all other Container tests in CSIT that use VPP.
+ configured with /8 IPv4 prefix routing.
Tests are designed such that in all tested cases VPP vswitch is the most
stressed application, as for each flow vswitch is processing each packet
Tests are designed such that in all tested cases VPP vswitch is the most
stressed application, as for each flow vswitch is processing each packet
@@
-103,9
+101,8
@@
physical core mapping ratios:
- (main:core) = (2:1) => 2mt1c - 2 Main Threads on 1 Core, 1 Thread
per NF, core shared between two NFs.
- (main:core) = (2:1) => 2mt1c - 2 Main Threads on 1 Core, 1 Thread
per NF, core shared between two NFs.
- - (data:core) = (2:1) => 1dt1c - 1 Data-plane Threads on 1 Core per
- NF.
-
+ - (data:core) = (2:1) => 2dt1c - 2 Data-plane Threads on 1 Core, 1
+ Thread per NF, core shared between two NFs.
Maximum tested service densities are limited by a number of physical
cores per NUMA. |csit-release| allocates cores within NUMA0. Support for
Maximum tested service densities are limited by a number of physical
cores per NUMA. |csit-release| allocates cores within NUMA0. Support for