- - **AF_XDP**: Added af_xdp driver support for all test cases. Test
- results will be added in sub-sequent CSIT-2106 report.
-
- - **GTPU tunnel**: Added GTPU HW Offload IPv4 routing tests.
-
- - **Intel Xeon Ice Lake**: Added initial test data for these
- platforms. Current CSIT-2106 report data for Intel Xeon Ice Lake
- comes from an external source (Intel labs running CSIT code on
- "8360Y D Stepping" and "6338N" processors). For details about the
- physical setup see :ref:`tested_physical_topologies`. Tested
- VPP and CSIT versions are pre-release, VPP
- 21.06-rc0~779-gd640ae52f.
-
- - **MLRsearch improvements**: Added support for multiple packet
- throughput rates in a single search, each rate is associated
- with a distinct Packet Loss Ratio (PLR) criterion. Previously
- only Non Drop Rate (NDR) (PLR=0) and single Partial Drop Rate
- (PDR) (PLR<0.5%) were supported. Implemented number of
- optimizations improving rate discovery efficiency.
-
- - **Reduction of tests**: Removed obsolete VPP use cases and
- superfluous test combinations from continuous and report test
- executions, including:
-
- - All vts tests, obsolete use cases.
- - dot1q tests apart from dot1q-l2bd, superfluous combinations.
- - -100flows, -100kflows in all acl tests.
- - nat44 tests
-
- - -pps tests, replaced by -tput tests.
- - h1-p1-s1 single session tests, unessential combination.
- - h4096-p63-s258048 tests, unessential scale combination.
-
- - ipsec tests
-
- - ethip4ipsectptlispgpe.
- - policy-aes128gcm.
- - policy-aes128cbc-hmac256sha.
- - policy-aes128cbc-hmac512sha.
- - int-aes128cbc-hmac256sha.
- - scale of
-
- - 400tnlsw.
- - 5000tnlsw.
- - 20000tnlsw.
- - 60000tnlsw.
+ - **Regressions with DPDK drivers**: Change from DPDK v21.08 to DPDK
+ v21.11 introduced regression across all tests using dpdk
+ drivers (with dpdk_plugin loaded). Compared to previous VPP
+ release performance drop varies in the range of -15% to -6%,
+ depending on test. It is related to updated MTU checks within
+ DPDK code and associated VPP code changes. See
+ `VPP v2202 release notes <https://s3-docs.fd.io/vpp/22.02/aboutvpp/releasenotes/v22.02.html>`_
+ and :ref:`vpp_known_issues`.
+
+ - **Number of CSIT 9000B frame tests failing**: tests with higher
+ encapsulation overhead are failing due to exceeding default
+ Ethernet Maximum Frame Size value that has been reduced by MTU
+ related VPP code changes. See
+ `VPP v2202 release notes <https://s3-docs.fd.io/vpp/22.02/aboutvpp/releasenotes/v22.02.html>`_
+ and :ref:`vpp_known_issues`.
+
+ - **Intel Xeon Ice Lake**: Performance test data for these platforms
+ is now provided by testbeds newly installed in FD.io CSIT labs.
+ For details about the physical setup see
+ :ref:`physical_testbeds_2n_icx` and
+ :ref:`physical_testbeds_3n_icx`.
+
+ - **Reduction of tests**: Removed certain test variations executed
+ iteratively for the report (as well as in daily and weekly
+ trending) due to physical testbeds overload.