| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC
| ... | NIC_Cisco-VIC-1227 | ETH | L2BDMACLRN | BASE
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC
| ... | NIC_Cisco-VIC-1227 | ETH | L2BDMACLRN | BASE
| ...
-| Test Setup | Performance test setup
-| Test Teardown | Performance test teardown | ${min_rate}pps | ${framesize}
+| Test Setup | Set up performance test
+| Test Teardown | Tear down performance discovery test | ${min_rate}pps | ${framesize}
| | Set Test Documentation | [Ver] Find NDR for ${framesize} Byte\ | append=True
| | Set Test Documentation | frames using binary search start at\ | append=True
| | Set Test Documentation | 10GE linerate, step ${threshold}pps. | append=True
| | Set Test Documentation | [Ver] Find NDR for ${framesize} Byte\ | append=True
| | Set Test Documentation | frames using binary search start at\ | append=True
| | Set Test Documentation | 10GE linerate, step ${threshold}pps. | append=True
-| | Add '${wt}' worker threads and rxqueues '${rxq}' in 3-node single-link topo
-| | Add PCI devices to DUTs from 3-node single link topology
-| | Run Keyword If | ${framesize} < ${1522} | Add No Multi Seg to all DUTs
+| | Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology
+| | Add PCI devices to DUTs in 3-node single link topology
+| | Run Keyword If | ${framesize} < ${1522} | Add no multi seg to all DUTs
| | Find NDR using binary search and pps
| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile}
| | ... | ${min_rate} | ${max_rate} | ${threshold}
| | Find NDR using binary search and pps
| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile}
| | ... | ${min_rate} | ${max_rate} | ${threshold}
| | Set Test Documentation | 10GE linerate, step ${threshold}pps, | append=True
| | Set Test Documentation | LT=${perf_pdr_loss_acceptance} | append=True
| | Set Test Documentation | ${perf_pdr_loss_acceptance_type}. | append=True
| | Set Test Documentation | 10GE linerate, step ${threshold}pps, | append=True
| | Set Test Documentation | LT=${perf_pdr_loss_acceptance} | append=True
| | Set Test Documentation | ${perf_pdr_loss_acceptance_type}. | append=True
-| | Add '${wt}' worker threads and rxqueues '${rxq}' in 3-node single-link topo
-| | Add PCI devices to DUTs from 3-node single link topology
-| | Run Keyword If | ${framesize} < ${1522} | Add No Multi Seg to all DUTs
+| | Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology
+| | Add PCI devices to DUTs in 3-node single link topology
+| | Run Keyword If | ${framesize} < ${1522} | Add no multi seg to all DUTs
| | Find PDR using binary search and pps
| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile}
| | ... | ${min_rate} | ${max_rate} | ${threshold}
| | Find PDR using binary search and pps
| | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile}
| | ... | ${min_rate} | ${max_rate} | ${threshold}