C-Docs: Optimize url links
[csit.git] / docs / content / release_notes / current / _index.md
diff --git a/docs/content/release_notes/current/_index.md b/docs/content/release_notes/current/_index.md
new file mode 100644 (file)
index 0000000..a231195
--- /dev/null
@@ -0,0 +1,111 @@
+---
+bookCollapseSection: true
+bookFlatSection: false
+title: "CSIT rls2306"
+weight: 1
+---
+
+# CSIT-2306 Release Report
+
+The format of FD.io CSIT reports has now changed. It is no longer available
+in the static html format.
+
+Instead current CSIT release information can be found in csit.fd.io.
+Previous CSIT releases are also linked from there.
+
+## CSIT-2306 Release Notes
+
+- [VPP Performance]({{< relref "vpp_performance" >}})
+- [DPDK Performance]({{< relref "dpdk_performance" >}})
+- [TRex Performance]({{< relref "trex_performance" >}})
+- [VPP Device]({{< relref "vpp_device" >}})
+
+## CSIT-2306 Release Data
+
+To access CSIT-2306 Release data please use following web resources:
+
+- [CSIT Per Release Performance](https://csit.fd.io/report/)
+  - `CSIT Release` > `rls2306`
+  - `DUT` > `vpp`
+  - `DUT Version` > `23.06-release`
+  - `Infra` > `testbed-nic-driver of choice`
+  - `Area` > `IPv4 Routing` `IPv4 Tunnels` `IPv6 Routing` `Hoststack` ...
+  - `Test` > `test of chioce`
+  - `Frame Size` > `64B` `78B`
+  - `Number of Cores` > `1C` `2C` `4C`
+  - `Test Type` > `MRR` `NDR` `PDR`
+- [CSIT Per Release Comparisons](https://csit.fd.io/comparisons/) for VPP
+  v23.06 vs v23.02
+  - `REFERENCE VALUE`
+    - `DUT` > `vpp`
+    - `CSIT and DUT version` > `rls2306-23.02-release`
+    - `Infra` > `testbed-nic-driver of choice`
+    - `Frame Size` > `64B` `78B`
+    - `Number of Cores` > `1C` `2C` `4C`
+    - `Measurement` > `Latency` `MRR` `NDR` `PDR`
+  - `COMPARED VALUE`
+    - `Parameter` > `Release and Version`
+    - `Value` > `rls2306-23.06-release`
+- [CSIT Per Release Coverage Data](https://csit.fd.io/coverage/)
+  - `CSIT Release` > `rls2306`
+
+## CSIT-2306 Selected Performance Tests
+
+CSIT-2306 VPP v23.06 Performance Tests:
+
+- ip4
+  - [2n-icx 100ge e810cq avf ip4scale20k](http://cuts2.com/zMwtS)
+  - [2n-spr 100ge e810cq avf ip4scale20k](http://cuts2.com/ahfvO)
+  - [2n-spr 100ge e810cq dpdk ip4scale20k](http://cuts2.com/yQCqU)
+  - [2n-spr 200ge cx7 dpdk ip4scale20k](http://cuts2.com/ZRERf)
+  - [2n-aws 50ge c5n.4xl ena dpdk ip4scale20k](http://cuts2.com/cwXOI)
+- ip6
+  - [2n-icx 100ge e810cq avf ip6scale20k](http://cuts2.com/QjBlW)
+  - [2n-spr 100ge e810cq avf ip6scale20k](http://cuts2.com/OmkQy)
+  - [2n-spr 100ge e810cq dpdk ip6scale20k](http://cuts2.com/qbpWI)
+  - [2n-spr 200ge cx7 dpdk ip6scale20k](http://cuts2.com/OtOzQ)
+  - [2n-aws 50ge c5n.4xl ena dpdk ip6scale20k](http://cuts2.com/Uopiv)
+- ipsec
+  - [3n-icx 100ge e810cq avf 40tnlsw](http://cuts2.com/XFLrM)
+  - [3n-icx 100ge cx6 dpdk 40tnlsw](http://cuts2.com/gzpDB)
+  - [3n-spr 100ge e810cq avf 40tnlsw](http://cuts2.com/NJeBW)
+  - [3n-spr 200ge cx7 dpdk 40tnlsw](http://cuts2.com/fUiMC)
+- hoststack quic
+  - [3n-icx 100ge e810cq dpdk ip4udpquic](http://cuts2.com/WTRoA)
+  - [3n-icx 100ge cx6 dpdk ip4udpquic](http://cuts2.com/ZGHEO)
+  - [3n-spr 100ge e810cq dpdk ip4udpquic](http://cuts2.com/LoBjd)
+  - [3n-spr 200ge cx7 dpdk ip4udpquic](http://cuts2.com/CODih)
+- hoststack tcp udp
+  - [3n-icx 100ge e810cq dpdk ip4tcp ipudp](http://cuts2.com/jlSrJ)
+  - [3n-icx 100ge cx6 dpdk ip4tcp ipudp](http://cuts2.com/Pkqng)
+  - [3n-spr 100ge e810cq dpdk ip4tcp ipudp](http://cuts2.com/RMWmj)
+  - [3n-spr 200ge cx7 dpdk ip4tcp ipudp](http://cuts2.com/cRVdc)
+- nat44
+  - [2n-icx 100ge e810cq avf ethip4tcp tput](http://cuts2.com/aLIBU)
+  - [2n-spr 100ge e810cq avf ethip4tcp-nat44ed tput](http://cuts2.com/loEKr)
+  - [2n-spr 100ge e810cq avf ethip4tcp-nat44ed cps](http://cuts2.com/boqsw)
+  - [2n-spr 200ge cx7 dpdk ethip4tcp-nat44ed tput](http://cuts2.com/QwXZd)
+- tunnels (gnv, vxlan, gtpu)
+  - [2n-icx 100ge e810cq avf ethip4udpgeneve](http://cuts2.com/VOrQr)
+  - [3n-icx 100ge cx6 dpdk gtpu sw](http://cuts2.com/uYTVT)
+  - [3n-spr 200ge cx7 dpdk vxlan](http://cuts2.com/iOYme)
+  - [3n-spr 200ge cx7 dpdk gtpu sw](http://cuts2.com/tZrfd)
+  - [3n-spr 200ge cx7 dpdk wireguard](http://cuts2.com/xKCia)
+- reassembly
+  - [3n-icx 100ge e810cq dpdk reassembly](http://cuts2.com/vBqTg)
+
+## CSIT-2306 Selected Performance Comparisons
+
+Comparisons 23.06 vs 23.02
+- [2n-icx 100ge e810cq avf 1c 64B PDR](http://cuts2.com/UBwMY)
+
+## CSIT-2306 Selected Performance Coverage Data
+
+CSIT-2306 VPP v23.06 coverage data
+- [2n-icx 200ge cx7 dpdk ip4](http://cuts2.com/EfqNe)
+
+## Further Information
+
+For further information including instructions how to access the needed
+information with user selectable options, please refer to
+[csit.fd.io documentation]({{< relref "/" >}}).