docs/lab: merged testbed specifications, separated out detailed HW and BIOS configs.
[csit.git] / docs / lab / Testbeds_Xeon_Skx_Arm_Atom.md
diff --git a/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md b/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md
deleted file mode 100644 (file)
index 3227ee0..0000000
+++ /dev/null
@@ -1,1560 +0,0 @@
-## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom
-
-This is a low-level design implemented as an extensions of FD.io CSIT lab to
-accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices.
-
-## Testbeds Overview
-
-### Testbeds Type Breakdown
-
-```
- #.  CSIT_tb.           Purpose.    SUT.  TG.   #tb.  #SUTs.  #TGs. #skx_node.
- 1.  1-node Xeon.       func.       skx.  n/a.  2.    2.      0.    2.
- 2.  2-node Xeon.       perf.       skx.  skx.  4.    4.      4.    8.
- 3.  3-node Xeon.       perf.       skx.  skx.  2.    4.      2.    6.
- 4.  tcp-l47.           tcp-stack.  skx.  ps1.  1.    1.      1.    1.
- 5.  atom-netgate.      perf+func.  net.  skx.  1.    3.      1.    1.
- 6.  aarch64-d05        perf        arm.  skx.  1.    2.      1.    1/2.
- 7.  aarch64-mcbin      perf        arm.  skx.  1.    2.      1.    1/2.
- 8.  1-node aarch64     func        arm.  n/a.  1.    1.      0.    0.
-                                                 Total skx_node:   19.
-```
-
-### 1-Node Xeon Testbeds
-
-One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6
-server), with NIC ports connected back-to-back.
-
-### 2-Node Xeon Testbeds
-
-Four 2-node Xeon testbeds (are expected to be built|are built), with each
-testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected
-back-to-back. NIC cards placement into slots and NIC ports connectivity is
-following the testbed specification included in next sections.
-
-### 3-Node Xeon Testbeds
-
-Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed
-using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh
-triangle. NIC cards placement into slots and NIC ports connectivity is following
-the testbed specification included in next sections.
-
-### 1-Node Arm Marvell ThunderX2 Testbed
-
-One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using
-one SUT (Type-9 server), with NIC ports connected back-to-back.
-
-### 3-Node Arm Huawei TaiShan Testbed
-
-One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3
-server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards
-placement into slots and NIC ports connectivity is following the testbed
-specification included in next sections.
-
-### 3-Node Arm Marvell MACCHIATObin Testbed
-
-One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs
-(Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
-Built-in NIC ports connectivity is following the testbed specification included
-in next sections.
-
-### TCP/IP and L47 Testbeds
-
-One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
-
-### Atom Testbeds
-One 3-node Atom (Netgate based) testbed is built consisting of three SUTs
-(Type-5 Netgate device.) NIC cards placement into slots and NIC ports
-connectivity is following the testbed specification included in the next
-section.
-
-## Inventory
-
-### Appliances
-
-```
-1. Ixia PerfectStorm One Appliance
-    - 1 * PS10GE4NG
-        - Chassis: PS10GE4NG.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: Quad-Core, Intel Processor.
-        - HW accelerators: FPGA offload.
-        - RAM Memory: 64GB.
-        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
-        - Physical Interfaces: 4 * 10GE SFP+.
-        - Operating System: Native IxOS.
-```
-
-### Arm Servers
-
-```
-1. Arm Cortex A-72 servers
-    - 1 * ThunderX2
-        - Chassis: Marvell ThunderX2
-        - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
-        - RAM Memory: 4* 32GB RDIMM
-        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
-    - 2 * Huawei TaiShan 2280.
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
-        - RAM Memory: 8* 16GB DDR4-2400MT/s.
-        - Disks: 1* 4TB SATA HDD.
-    - 3 * MACCHIATObin
-        - Chassis: MACCHIATObin.
-        - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
-        - RAM Memory: 1* 16GB DDR4.
-        - Disks: 1* 128GB(?) SATA SDD.
-```
-
-Platform Name and Specification | Role | Status | Hostname | IP | IPMI | Cores | RAM | Ethernet | Distro
-------------------------------- | ---- | ------ | -------- | -- | ---- | ----- | --- | -------- | ------
-[SoftIron OverDrive 1000](https://softiron.com/development-tools/overdrive-1000/) | CI build server | Up, Not Running Jobs | softiron-1 | 10.30.51.12 | N/A | 4 | 8GB |  | openSUSE
-  | | CI build server | Up, Not Running Jobs | softiron-2 | 10.30.51.13 | N/A | 4 | 8GB |   | openSUSE
-  | | CI build server | Up, Not Running Jobs | softiron-3 | 10.30.51.14 | N/A | 4 | 8GB |   | openSUSE
-[Marvell ThunderX](https://www.marvell.com/server-processors/thunderx-arm-processors/) | CI build server | Up, Running VPP CI | nomad3arm | 10.30.51.38 | 10.30.50.38 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
-  | | CI build server | Up, Running VPP CI | nomad4arm | 10.30.51.39 | 10.30.50.39 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
-  | | CI build server | Up, Running VPP CI | nomad5arm | 10.30.51.40 | 10.30.50.40 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04
-  | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad6arm | 10.30.51.65 | 10.30.50.65 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
-  | | VPP dev debug | Up | nomad7arm | 10.30.51.66 | 10.30.50.66 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1
-  | | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | nomad8arm | 10.30.51.67 | 10.30.50.67 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
-  | | VPP dev debug | Up | nomad9arm | 10.30.51.68 | 10.30.50.68 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1
-[Marvell ThunderX2](https://www.marvell.com/server-processors/thunderx2-arm-processors/) | VPP device server | Being Provisioned | s27-t13-sut1 | 10.30.51.69 | 10.30.50.69 | 112 | 128GB | 3x40GbE QSFP+ XL710-QDA2 | Ubuntu 18.04.1
-Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-sut1 | 10.30.51.36 | 10.30.50.36 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
-  | | CSIT Performance | Up, Manual perf experiments | s18-t33-sut2 | 10.30.51.37 | 10.30.50.37 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10
-[Marvell MACCHIATObin](http://macchiatobin.net/) | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s20-t34-sut1 | 10.30.51.41 | 10.30.51.49, then connect to /dev/ttyUSB0 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.4
-  | | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s21-t34-sut2 | 10.30.51.42 | 10.30.51.49, then connect to /dev/ttyUSB1 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
-  | | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
-
-### Xeon and Atom Servers
-
-```
-1. Intel Xeon servers:
-    - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-2. Intel Atom servers with Rangely processors.
-    - 3 * Netgate XG-2758-1u
-        - Chassis: Netgate XG-2758-1u
-        - Processors: 1* Rangely (Atom) C2758 2.4 GHz
-        - RAM Memory: 16GB ECC
-        - Disks: 150 GB
-```
-
-### Network Interface Cards
-
-```
-1. 10GE NICs
-    - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
-    - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
-    - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
-2. 25GE NICs
-    - 12 * Intel® Ethernet Network Adapter XXV710-DA2
-3. 40GE NICs
-    - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
-4. 100GE NICs
-    - 4 * mcx556a-edat NICs (not on site yet, in transit)
-```
-
-### Pluggables and Cables
-
-Pluggables:
-
-```
-1. 10GE SFP+
-    - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
-    - 80 * 10G SR optic (generic, "Intel" compatible branded)
-2. 25GE SFP28
-    - None
-3. 40GE QSFP+
-    - None
-4. 100GE
-    - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
-```
-
-Standalone cables:
-
-```
-1. 10GE
-    - None
-2. 25GE
-    - None
-3. 40GE QSFP+
-    - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
-4. 100GE
-    - None
-```
-
-### Other Network Cards
-
-Any QATs?
-
-## Installation Status
-
-Lab installation status is tracked by LF IT team in
-[FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
-
-## Server/Device Management and Naming
-
-### Server Management Requirements
-
-Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
-For management purposes, each server must have following two ports connected to
-the management network:
-
-```
-- 1GE IPMI port
-  - IPMI - Intelligent Platform Management Interface.
-  - Required for access to embedded server management with WebUI, CLI, SNMPv3,
-    IPMIv2.0, for firmware (BIOS) and OS updates.
-- 1GE/10GE management port
-  - hostOS management port for general system management.
-```
-
-### Server and Port Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
-- testbedname: testbedN.
-- hostname:
-    - traffic-generator: tN-tgW.
-    - system-under-testX: tN-sutX.
-- portnames:
-    - tN-tgW-cY/pZ.
-    - tN-sutX-cY/pZ.
-- where:
-    - N - testbed number.
-    - tgW - server acts as traffic-generator with W index.
-    - sutX - server acts as system-under-test with X index.
-    - Y - PCIe slot number denoting a NIC card number within the host.
-        - Y=2,4,9 - slots connected to NUMA node 0.
-        - Y=6,8,10 - slots connected to NUMA node 1.
-    - Z - port number on the NIC card.
-```
-
-### Server Management - Addressing
-
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
-port, which are connected to two different VLANs.
-
-```
-1. LOM (IPMI) VLAN:
-    - Subnet: 10.30.50.0/24
-    - Gateway: 10.30.50.1
-    - Broadcast: 10.30.50.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
-2. Management Vlan:
-    - Subnet: 10.30.51.0/24
-    - Gateway: 10.30.51.1
-    - Broadcast: 10.30.51.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
-```
-
-To access these hosts, an VPN connection is required.
-
-### LOM (IPMI) VLAN IP Addresses
-..
-
-### Management VLAN IP Addresses
-..
-
-## Testbeds Specification - Target Build
-
-### Server/Ports Naming, NIC Placement
-
-#### 1-Node Xeon
-
-Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and
-ports indexed per following specification:
-
-```
-- Server1 [Type-6]:
-    - testbedname: testbed11.
-    - hostname: s1-t11-sut1.
-    - IPMI IP: 10.30.50.47
-    - Host IP: 10.30.51.50
-    - portnames:
-        - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
-        - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
-        - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
-        - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- Server2 [Type-6]:
-    - testbedname: testbed12.
-    - hostname: s2-t12-sut1.
-    - IPMI IP: 10.30.50.48
-    - Host IP: 10.30.51.51
-    - portnames:
-        - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
-        - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
-        - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
-        - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node Xeon
-
-Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and
-ports indexed per following specification:
-
-```
-- Server3 [Type-1]:
-    - testbedname: testbed21.
-    - hostname: s3-t21-sut1.
-    - IPMI IP: 10.30.50.41
-    - Host IP: 10.30.51.44
-    - portnames:
-        - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server4 [Type-2]:
-    - testbedname: testbed21.
-    - hostname: s4-t21-tg1.
-    - IPMI IP: 10.30.50.42
-    - Host IP: 10.30.51.45
-    - portnames:
-        - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server5 [Type-1]:
-    - testbedname: testbed22.
-    - hostname: s5-t22-sut1.
-    - IPMI IP: 10.30.50.49
-    - Host IP: 10.30.51.52
-    - portnames:
-        - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server6 [Type-2]:
-    - testbedname: testbed22.
-    - hostname: s6-t22-tg1.
-    - IPMI IP: 10.30.50.50
-    - Host IP: 10.30.51.53
-    - portnames:
-        - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server7 [Type-1]:
-    - testbedname: testbed23.
-    - hostname: s7-t23-sut1.
-    - IPMI IP: 10.30.50.51
-    - Host IP: 10.30.51.54
-    - portnames:
-        - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server8 [Type-2]:
-    - testbedname: testbed23.
-    - hostname: s8-t23-tg1.
-    - IPMI IP: 10.30.50.52
-    - Host IP: 10.30.51.55
-    - portnames:
-        - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server9 [Type-1]:
-    - testbedname: testbed24.
-    - hostname: s9-t24-sut1.
-    - IPMI IP: 10.30.50.53
-    - Host IP: 10.30.51.56
-    - portnames:
-        - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server10 [Type-2]:
-    - testbedname: testbed24.
-    - hostname: s10-t24-tg1.
-    - IPMI IP: 10.30.50.54
-    - Host IP: 10.30.51.57
-    - portnames:
-        - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 3-Node Xeon
-
-Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and
-ports indexed per following specification:
-
-```
-- Server11 [Type-1]:
-    - testbedname: testbed31.
-    - hostname: s11-t31-sut1.
-    - IPMI IP: 10.30.50.43
-    - Host IP: 10.30.51.46
-    - portnames:
-        - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server12 [Type-1]:
-    - testbedname: testbed31.
-    - hostname: s12-t31-sut2.
-    - IPMI IP: 10.30.50.44
-    - Host IP: 10.30.51.47
-    - portnames:
-        - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server13 [Type-2]:
-    - testbedname: testbed31.
-    - hostname: s13-t31-tg1.
-    - IPMI IP: 10.30.50.45
-    - Host IP: 10.30.51.48
-    - portnames:
-        - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server14 [Type-1]:
-    - testbedname: testbed32.
-    - hostname: s14-t32-sut1.
-    - IPMI IP: 10.30.50.55
-    - Host IP: 10.30.51.58
-    - portnames:
-        - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server15 [Type-1]:
-    - testbedname: testbed32.
-    - hostname: s15-t32-sut2.
-    - IPMI IP: 10.30.50.56
-    - Host IP: 10.30.51.59
-    - portnames:
-        - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- Server16 [Type-2]:
-    - testbedname: testbed32.
-    - hostname: s16-t32-tg1.
-    - IPMI IP: 10.30.50.57
-    - Host IP: 10.30.51.60
-    - portnames:
-        - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 1-Node Arm
-
-```
-- Server17 [Type-3]:
-    - testbedname: testbed13.
-    - hostname: s27-t13-sut1.
-    - IPMI IP: 10.30.50.69
-    - Host IP: 10.30.51.69
-    - portnames:
-        - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-```
-
-#### 3-Node Arm
-
-Note: Server19 (TG) is shared between testbed33 & testbed34
-
-```
-- Server17 [Type-3]:
-    - testbedname: testbed33.
-    - hostname: s17-t33-sut1.
-    - IPMI IP: 10.30.50.36
-    - Host IP: 10.30.51.36
-    - portnames:
-        - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
-        - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
-        - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
-        - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- Server18 [Type-3]:
-    - testbedname: testbed33.
-    - hostname: s18-t33-sut2.
-    - IPMI IP: 10.30.50.37
-    - Host IP: 10.30.51.37
-    - portnames:
-        - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
-        - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
-        - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
-        - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- Server19 [Type-2]:
-    - testbednames: testbed33 and testbed34.
-    - hostname: s19-t33t34-tg1.
-    - IPMI IP: 10.30.50.46
-    - Host IP: 10.30.51.49
-    - portnames:
-        - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- Server20 [Type-4]:
-    - testbedname: testbed34.
-    - hostname: s20-t34-sut1.
-    - IPMI IP: N/A
-    - Host IP: 10.30.51.41
-    - portnames:
-        - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
-        - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
-- Server21 [Type-4]:
-    - testbedname: testbed34.
-    - hostname: s21-t34-sut2.
-    - IPMI IP: N/A
-    - Host IP: 10.30.51.42
-    - portnames:
-        - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
-        - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
-```
-
-#### TCP/IP and L47
-
-Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and
-NIC cards and ports indexed per following specification:
-
-```
-- Server25 [Type-8]:
-    - testbedname: testbed25.
-    - hostname: s25-t25-sut1.
-    - IPMI IP: 10.30.50.58
-    - Host IP: 10.30.51.61
-    - portnames:
-        - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- Server26 [Type-7]:
-    - testbedname: testbed25.
-    - hostname: s26-t25-tg1.
-    - IPMI IP: 10.30.50.59
-    - Host IP: 10.30.51.62
-    - portnames:
-        - s26-t25-tg1-p1 - 10GE-port1.
-        - s26-t25-tg1-p2 - 10GE-port2.
-        - s26-t25-tg1-p3 - 10GE-port3.
-        - s26-t25-tg1-p4 - 10GE-port4.
-```
-
-#### 3-Node Atom
-
-Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
-
-```
-- Server22 [Type-5]:
-    - testbedname: testbed35.
-    - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
-    - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
-    - Host IP: 10.30.51.9
-    - portnames:
-        - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
-        - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
-    - 1GB ports (tbd)
-- Server23 [Type-5]:
-    - testbedname: testbed35.
-    - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
-    - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
-    - Host IP: 10.30.51.10
-    - portnames:
-        - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
-        - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
-    - 1GB ports (tbd)
-- Server24 [Type-5]:
-    - testbedname: testbed35.
-    - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
-    - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
-    - Host IP: 10.30.51.11
-    - portnames:
-        - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
-        - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
-    - 1GB ports (tbd)
-```
-
-### Physical Connectivity within Testbeds
-
-#### 1-Node Xeon
-
-Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below
-specification:
-
-```
-- testbed11:
-    - ring1 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
-    - ring2 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
-    - ring3 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
-    - ring4 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
-- testbed12:
-    - ring1 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
-    - ring2 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
-    - ring3 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
-    - ring4 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
-```
-
-#### 2-Node Xeon
-
-Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below
-specification:
-
-```
-- testbed21:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
-        - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
-        - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
-        - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
-        - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
-        - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
-- testbed22:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
-        - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
-        - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
-        - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
-        - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
-        - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
-- testbed23:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
-        - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
-        - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
-        - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
-        - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
-        - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
-- testbed24:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
-        - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
-        - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
-        - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
-        - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
-        - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
-```
-
-#### 3-Node Xeon
-
-Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below
-specification:
-
-```
-- testbed31:
-    - ring1 10GE-ports x710-4p10GE on SUTs:
-        - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
-        - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
-        - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
-        - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
-        - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
-        - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
-        - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
-        - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
-        - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
-        - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
-    - ring1 10GE-ports x710-4p10GE on SUTs:
-        - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
-        - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
-        - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
-        - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
-        - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
-        - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
-        - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
-        - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
-        - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
-        - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
-
-#### 1-Node Arm
-
-One 1-Node testbed is constructed by connecting 1 Arm server using below
-specification:
-
-```
-- testbed13:
-    - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
-    - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
-    - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
-```
-
-#### 3-Node Arm
-
-One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon
-server using below specification:
-
-```
-- testbed33:
-    - ring1 10GE-ports 82599-2p10GE on SUTs:
-        - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
-        - t33-sut1-c6/p1 - t33-sut2-c6/p2.
-        - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
-    - ring2 25GE-ports cx4-2p25GE on SUTs:
-        - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
-        - t33-sut1-c4/p1 - t33-sut2-c4/p2.
-        - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
-```
-
-One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one
-Xeon server using below specification:
-
-```
-- testbed34:
-    - ring1 10GE-ports Marvell on SUTs:
-        - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
-        - t34-sut1-ca/p2 - t34-sut2-ca/p1.
-        - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
-```
-
-#### TCP/IP and L47
-
-One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon
-server using below specification:
-
-```
-- testbed25:
-    - link1 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p1 to t25-sut1-c2/p1.
-    - link2 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p2 to t25-sut1-c2/p2.
-    - link3 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p3 to t25-sut1-c2/p3.
-    - link4 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p4 to t25-sut1-c2/p4.
-```
-
-#### 3-Node Atom
-
-..
-
-## Server Specification
-
-### Hardware Configuration
-
-The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
-server configurations:
-
-```
-1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e.
-   VPP, testpmd.
-    - Quantity: TBD based on testbed allocation.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex.
-    - Quantity: TBD based on testbed allocation.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload
-   i.e. VPP, testpmd.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI(?) and host management ports.
-        - NIC ports connected into 3-node topology.
-    - Main HW configuration:
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
-        - RAM Memory: 8* 16GB DDR4-2400MT/s
-        - Disks: 1* 4TB SATA HDD
-    - NICs configuration:
-        - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
-        - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
-4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload
-   i.e. VPP, testpmd.
-    - Quantity: 3
-    - Physical connectivity:
-        - Host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: MACCHIATObin.
-        - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
-        - RAM Memory: 1* 16GB DDR4
-        - Disks: 1* 128GB(?) SATA SDD
-    - NICs configuration:
-        - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e.
-   VPP, testpmd.
-    - Quantity: TBD based on testbed allocation.
-    - Physical connectivity:
-        - Management: serial Port (usb) for console
-        - NIC ports connected into 2-node.
-    - Main HW configuration:
-        - Chassis: Netgate XG-2758-1u
-        - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
-        - RAM Memory: 16GB ECC
-        - Disks: 150 GB
-    - NICs configuration:
-        - 2x 10Gb Intel 82599ES
-        - 4x 1GB Intel I354
-6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance
-   tests.
-    - Quantity: 1.
-    - Physical connectivity:
-        - Host management interface: 10/100/1000-BaseT.
-        - 8-port 10GE SFP+ integrated NIC.
-    - Main HW configuration:
-        - Chassis: PS10GE4NG.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: Quad-Core, Intel Processor.
-        - HW accelerators: FPGA offload.
-        - RAM Memory: 64GB.
-        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
-        - Physical Interfaces: 4 * 10GE SFP+.
-        - Operating System: Native IxOS.
-    - Interface configuration:
-        - Port-1: 10GE SFP+.
-        - Port-2: 10GE SFP+.
-        - Port-3: 10GE SFP+.
-        - Port-4: 10GE SFP+.
-8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: empty.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional
-   tests.
-    - Quantity: 1
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 1-node topologies.
-    - Main HW configuration:
-        - Chassis: Gigabyte R181-T90 1U
-        - Motheboard: MT91-FS1
-        - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
-        - RAM Memory: 4* 32GB RDIMM
-        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
-    - NICs configuration:
-        - Numa0:
-            - PCIe Slot1 05:00.xx: XL710-QDA2.
-            - PCIe Slot3 08:00.xx: XL710-QDA2.
-        - Numa1:
-            - PCIe Slot6 85:00.xx: XL710-QDA2.
-10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane
-    Workload i.e. VPP, testpmd.
-    - Quantity: 4
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-E300-9A
-        - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
-        - RAM Memory: 32GB ECC
-        - Disks: 480 GB
-    - NICs configuration:
-        - 2x 10Gb Intel x553 fiber ports
-        - 2x 10Gb Intel x553 copper ports
-        - 4x 1GB Intel I350 ports
-```
-
-### Xeon Skx Server BIOS Configuration
-
-#### Boot Feature
-
-```
-  |  Quiet Boot                                [Enabled]               |Boot option                  |
-  |                                                                    |                             |
-  |  Option ROM Messages                       [Force BIOS]            |                             |
-  |  Bootup NumLock State                      [On]                    |                             |
-  |  Wait For "F1" If Error                    [Enabled]               |                             |
-  |  INT19 Trap Response                       [Immediate]             |                             |
-  |  Re-try Boot                               [Disabled]              |                             |
-  |  Install Windows 7 USB support             [Disabled]              |                             |
-  |  Port 61h Bit-4 Emulation                  [Disabled]              |                             |
-  |                                                                    |                             |
-  |  Power Configuration                                               |                             |
-  |  Watch Dog Function                        [Disabled]              |                             |
-  |  Restore on AC Power Loss                  [Last State]            |                             |
-  |  Power Button Function                     [Instant Off]           |                             |
-  |  Throttle on Power Fail                    [Disabled]              |                             |
-```
-
-#### CPU Configuration
-
-```
-  |  Processor Configuration                                           |Enables Hyper Threading      |
-  |  --------------------------------------------------                |(Software Method to          |
-  |  Processor BSP Revision                    50654 - SKX H0          |Enable/Disable Logical       |
-  |  Processor Socket                          CPU1      |  CPU2       |Processor threads.           |
-  |  Processor ID                              00050654* |  000506...  |                             |
-  |  Processor Frequency                       2.500GHz  |  2.500GHz   |                             |
-  |  Processor Max Ratio                            19H  |  19H        |                             |
-  |  Processor Min Ratio                            0AH  |  0AH        |                             |
-  |  Microcode Revision                        02000030                |                             |
-  |  L1 Cache RAM                                  64KB  |      64KB   |                             |
-  |  L2 Cache RAM                                1024KB  |    1024KB   |                             |
-  |  L3 Cache RAM                               39424KB  |   39424KB   |                             |
-  |  Processor 0 Version                                               |                             |
-  |  Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz                      |                             |
-  |  Processor 1 Version                                               |                             |
-  |  Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz                      |                             |
-  |                                                                    |                             |
-  |  Hyper-Threading [ALL]                     [Enable]                |                             |
-  |  Core Disable Bitmap(Hex)                  0                       |                             |
-  |  Execute Disable Bit                       [Enable]                |                             |
-  |  Intel Virtualization Technology           [Enable]                |                             |
-  |  PPIN Control                              [Unlock/Enable]         |                             |
-  |  Hardware Prefetcher                       [Enable]                |                             |
-  |  Adjacent Cache Prefetch                   [Enable]                |                             |
-  |  DCU Streamer Prefetcher                   [Enable]                |                             |
-  |  DCU IP Prefetcher                         [Enable]                |                             |
-  |  LLC Prefetch                              [Disable]               |                             |
-  |  Extended APIC                             [Disable]               |                             |
-  |  AES-NI                                    [Enable]                |                             |
-  |> Advanced Power Management Configuration                           |                             |
-```
-
-##### Advanced Power Management Configuration
-
-```
-  |  Advanced Power Management Configuration                           |Switch CPU Power Management  |
-  |  --------------------------------------------------                |profile                      |
-  |  Power Technology                          [Custom]                |                             |
-  |  Power Performance Tuning                  [BIOS Controls EPB]     |                             |
-  |  ENERGY_PERF_BIAS_CFG mode                 [Maximum Performance]   |                             |
-  |> CPU P State Control                                               |                             |
-  |> Hardware PM State Control                                         |                             |
-  |> CPU C State Control                                               |                             |
-  |> Package C State Control                                           |                             |
-  |> CPU T State Control                                               |                             |
-```
-
-###### CPU P State Control
-
-```
-  |  CPU P State Control                                               |Enable/Disable EIST          |
-  |                                                                    |(P-States)                   |
-  |  SpeedStep (Pstates)                       [Disable]               |                             |
-  |  EIST PSD Function                         [HW_ALL]                |                             |
-```
-
-###### Hardware PM State Control
-
-```
-  |  Hardware PM State Control                                         |Disable: Hardware chooses a  |
-  |                                                                    |P-state based on OS Request  |
-  |  Hardware P-States                         [Disable]               |(Legacy P-States)            |
-  |                                                                    |Native Mode:Hardware         |
-  |                                                                    |chooses a P-state based on   |
-  |                                                                    |OS guidance                  |
-  |                                                                    |Out of Band Mode:Hardware    |
-  |                                                                    |autonomously chooses a       |
-  |                                                                    |P-state (no OS guidance)     |
-```
-
-###### CPU C State Control
-
-```
-  |  CPU C State Control                                               |Autonomous Core C-State      |
-  |                                                                    |Control                      |
-  |  Autonomous Core C-State                   [Disable]               |                             |
-  |  CPU C6 report                             [Disable]               |                             |
-  |  Enhanced Halt State (C1E)                 [Disable]               |                             |
-```
-
-###### Package C State Control
-
-```
-  |  Package C State Control                                           |Package C State limit        |
-  |                                                                    |                             |
-  |  Package C State                           [C0/C1 state]           |                             |
-```
-
-###### CPU T State Control
-
-```
-  |  CPU T State Control                                               |Enable/Disable Software      |
-  |                                                                    |Controlled T-States          |
-  |  Software Controlled T-States              [Disable]               |                             |
-```
-
-##### Chipset Configuration
-
-```
-  |  WARNING: Setting wrong values in below sections may cause         |North Bridge Parameters      |
-  |           system to malfunction.                                   |                             |
-  |> North Bridge                                                      |                             |
-  |> South Bridge                                                      |                             |
-```
-
-###### North Bridge
-
-```
-  |> UPI Configuration                                                 |Displays and provides        |
-  |> Memory Configuration                                              |option to change the UPI     |
-  |> IIO Configuration                                                 |Settings                     |
-```
-
-###### UPI Configuration
-
-```
-  |  UPI Configuration                                                 |Choose Topology Precedence   |
-  |  --------------------------------------------------                |to degrade features if       |
-  |  Number of CPU                             2                       |system options are in        |
-  |  Number of Active UPI Link                 3                       |conflict or choose Feature   |
-  |  Current UPI Link Speed                    Fast                    |Precedence to degrade        |
-  |  Current UPI Link Frequency                10.4 GT/s               |topology if system options   |
-  |  UPI Global MMIO Low Base / Limit          90000000 / FBFFFFFF     |are in conflict.             |
-  |  UPI Global MMIO High Base / Limit         0000000000000000 / ...  |                             |
-  |  UPI Pci-e Configuration Base / Size       80000000 / 10000000     |                             |
-  |  Degrade Precedence                        [Topology Precedence]   |                             |
-  |  Link L0p Enable                           [Disable]               |                             |
-  |  Link L1 Enable                            [Disable]               |                             |
-  |  IO Directory Cache (IODC)                 [Auto]                  |                             |
-  |  SNC                                       [Disable]               |                             |
-  |  XPT Prefetch                              [Disable]               |                             |
-  |  KTI Prefetch                              [Enable]                |                             |
-  |  Local/Remote Threshold                    [Auto]                  |                             |
-  |  Stale AtoS                                [Disable]               |                             |
-  |  LLC dead line alloc                       [Enable]                |                             |
-  |  Isoc Mode                                 [Auto]                  |                             |
-```
-
-###### Memory Configuration
-
-```
-  |                                                                    |POR - Enforces Plan Of       |
-  |  --------------------------------------------------                |Record restrictions for      |
-  |  Integrated Memory Controller (iMC)                                |DDR4 frequency and voltage   |
-  |  --------------------------------------------------                |programming. Disable -       |
-  |                                                                    |Disables this feature.       |
-  |  Enforce POR                               [Disable]               |                             |
-  |  Memory Frequency                          [2666]                  |                             |
-  |  Data Scrambling for NVMDIMM               [Auto]                  |                             |
-  |  Data Scrambling for DDR4                  [Auto]                  |                             |
-  |  tCCD_L Relaxation                         [Auto]                  |                             |
-  |  Memory tRWSR Relaxation                   [Enable]                |                             |
-  |  2X REFRESH                                [Auto]                  |                             |
-  |  Page Policy                               [Auto]                  |                             |
-  |  IMC Interleaving                          [2-way Interleave]      |                             |
-  |> Memory Topology                                                   |                             |
-  |> Memory RAS Configuration                                          |                             |
-```
-
-###### IIO Configuration
-
-```
-  |  IIO Configuration                                                 |Expose IIO DFX devices and   |
-  |  --------------------------------------------------                |other CPU devices like PMON  |
-  |                                                                    |                             |
-  |  EV DFX Features                           [Disable]               |                             |
-  |> CPU1 Configuration                                                |                             |
-  |> CPU2 Configuration                                                |                             |
-  |> IOAT Configuration                                                |                             |
-  |> Intel. VT for Directed I/O (VT-d)                                 |                             |
-  |> Intel. VMD technology                                             |                             |
-  |                                                                    |                             |
-  |   IIO-PCIE Express Global Options                                  |                             |
-  |  ========================================                          |                             |
-  |  PCI-E Completion Timeout Disable          [No]                    |                             |
-```
-
-###### CPU1 Configuration
-
-```
-  |  IOU0 (IIO PCIe Br1)                       [Auto]                  |Selects PCIe port            |
-  |  IOU1 (IIO PCIe Br2)                       [Auto]                  |Bifurcation for selected     |
-  |  IOU2 (IIO PCIe Br3)                       [Auto]                  |slot(s)                      |
-  |> CPU1 SLOT2 PCI-E 3.0 X16                                          |                             |
-  |> CPU1 SLOT4 PCI-E 3.0 X16                                          |                             |
-  |> CPU1 SLOT9 PCI-E 3.0 X16                                          |                             |
-```
-
-###### CPU2 Configuration
-
-```
-  |  IOU0 (IIO PCIe Br1)                       [Auto]                  |Selects PCIe port            |
-  |  IOU1 (IIO PCIe Br2)                       [Auto]                  |Bifurcation for selected     |
-  |  IOU2 (IIO PCIe Br3)                       [Auto]                  |slot(s)                      |
-  |> CPU2 SLOT6 PCI-E 3.0 X16                                          |                             |
-  |> CPU2 SLOT8 PCI-E 3.0 X16                                          |                             |
-  |> CPU2 SLOT10 PCI-E 3.0 X16                                         |                             |
-```
-
-##### South Bridge
-
-```
-  |                                                                    |Enables Legacy USB support.  |
-  |  USB Module Version                        17                      |AUTO option disables legacy  |
-  |                                                                    |support if no USB devices    |
-  |  USB Devices:                                                      |are connected. DISABLE       |
-  |        1 Keyboard, 1 Mouse, 1 Hub                                  |option will keep USB         |
-  |                                                                    |devices available only for   |
-  |  Legacy USB Support                        [Enabled]               |EFI applications.            |
-  |  XHCI Hand-off                             [Disabled]              |                             |
-  |  Port 60/64 Emulation                      [Enabled]               |                             |
-  |  PCIe PLL SSC                              [Disable]               |                             |
-  |  Real USB Wake Up                          [Enabled]               |                             |
-  |  Front USB Wake Up                         [Enabled]               |                             |
-  |                                                                    |                             |
-  |  Azalia                                    [Auto]                  |                             |
-  |    Azalia PME Enable                       [Disabled]              |                             |
-```
-
-#### PCIe/PCI/PnP Configuration
-
-```
-  |  PCI Bus Driver Version                    A5.01.12                |Enables or Disables 64bit    |
-  |                                                                    |capable Devices to be        |
-  |  PCI Devices Common Settings:                                      |Decoded in Above 4G Address  |
-  |  Above 4G Decoding                         [Enabled]               |Space (Only if System        |
-  |  SR-IOV Support                            [Enabled]               |Supports 64 bit PCI          |
-  |  MMIO High Base                            [56T]                   |Decoding).                   |
-  |  MMIO High Granularity Size                [256G]                  |                             |
-  |  Maximum Read Request                      [Auto]                  |                             |
-  |  MMCFG Base                                [2G]                    |                             |
-  |  NVMe Firmware Source                      [Vendor Defined Fi...]  |                             |
-  |  VGA Priority                              [Onboard]               |                             |
-  |  CPU1 SLOT2 PCI-E 3.0 X16 OPROM            [Legacy]                |                             |
-  |  CPU1 SLOT4 PCI-E 3.0 X16 OPROM            [Legacy]                |                             |
-  |  CPU2 SLOT6 PCI-E 3.0 X16 OPROM            [Legacy]                |                             |
-  |  CPU2 SLOT8 PCI-E 3.0 X16 OPROM            [Legacy]                |                             |
-  |  CPU1 SLOT9 PCI-E 3.0 X16 OPROM            [Legacy]                |                             |
-  |  CPU2 SLOT10 PCI-E 3.0 X16 OPROM           [Legacy]                |                             |
-  |  CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM     [Legacy]                |                             |
-  |  M.2 CONNECTOR OPROM                       [Legacy]                |                             |
-  |  Onboard LAN1 Option ROM                   [Legacy]                |                             |
-  |  Onboard LAN2 Option ROM                   [Disabled]              |                             |
-  |  Onboard Video Option ROM                  [Legacy]                |                             |
-  |> Network Stack Configuration                                       |                             |
-```
-
-#### ACPI Settings
-
-```
-  |  ACPI Settings                                                     |Enable or Disable Non        |
-  |                                                                    |uniform Memory Access        |
-  |  NUMA                                      [Enabled]               |(NUMA).                      |
-  |  WHEA Support                              [Enabled]               |                             |
-  |  High Precision Event Timer                [Enabled]               |                             |
-  |  ACPI Sleep State                          [S3 (Suspend to RAM)]   |                             |
-```
-
-#### DMIDECODE
-
-```
-  # dmidecode 3.1
-  Getting SMBIOS data from sysfs.
-  SMBIOS 3.1.1 present.
-  Table at 0x000E89C0.
-
-  Handle 0x0000, DMI type 0, 26 bytes
-  BIOS Information
-        Vendor: American Megatrends Inc.
-        Version: 2.0
-        Release Date: 11/29/2017
-        Address: 0xF0000
-        Runtime Size: 64 kB
-        ROM Size: 64 MB
-        Characteristics:
-                PCI is supported
-                BIOS is upgradeable
-                BIOS shadowing is allowed
-                Boot from CD is supported
-                Selectable boot is supported
-                BIOS ROM is socketed
-                EDD is supported
-                5.25"/1.2 MB floppy services are supported (int 13h)
-                3.5"/720 kB floppy services are supported (int 13h)
-                3.5"/2.88 MB floppy services are supported (int 13h)
-                Print screen service is supported (int 5h)
-                Serial services are supported (int 14h)
-                Printer services are supported (int 17h)
-                ACPI is supported
-                USB legacy is supported
-                BIOS boot specification is supported
-                Targeted content distribution is supported
-                UEFI is supported
-        BIOS Revision: 5.12
-
-  Handle 0x0001, DMI type 1, 27 bytes
-  System Information
-        Manufacturer: Supermicro
-        Product Name: SYS-7049GP-TRT
-        Version: 0123456789
-        Serial Number: S291427X8332242
-        UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
-        Wake-up Type: Power Switch
-        SKU Number: To be filled by O.E.M.
-        Family: To be filled by O.E.M.
-
-  Handle 0x0002, DMI type 2, 15 bytes
-  Base Board Information
-        Manufacturer: Supermicro
-        Product Name: X11DPG-QT
-        Version: 1.02
-        Serial Number: VM183S014930
-        Asset Tag: To be filled by O.E.M.
-        Features:
-                Board is a hosting board
-                Board is replaceable
-        Location In Chassis: To be filled by O.E.M.
-        Chassis Handle: 0x0003
-        Type: Motherboard
-        Contained Object Handles: 0
-
-  Handle 0x0003, DMI type 3, 22 bytes
-  Chassis Information
-        Manufacturer: Supermicro
-        Type: Other
-        Lock: Not Present
-        Version: 0123456789
-        Serial Number: C7470KH06A20167
-        Asset Tag: To be filled by O.E.M.
-        Boot-up State: Safe
-        Power Supply State: Safe
-        Thermal State: Safe
-        Security Status: None
-        OEM Information: 0x00000000
-
-  Handle 0x0050, DMI type 4, 48 bytes
-  Processor Information
-        Socket Designation: CPU1
-        Type: Central Processor
-        Family: Xeon
-        Manufacturer: Intel(R) Corporation
-        ID: 54 06 05 00 FF FB EB BF
-        Signature: Type 0, Family 6, Model 85, Stepping 4
-        Flags:
-                FPU (Floating-point unit on-chip)
-                VME (Virtual mode extension)
-                DE (Debugging extension)
-                PSE (Page size extension)
-                TSC (Time stamp counter)
-                MSR (Model specific registers)
-                PAE (Physical address extension)
-                MCE (Machine check exception)
-                CX8 (CMPXCHG8 instruction supported)
-                APIC (On-chip APIC hardware supported)
-                SEP (Fast system call)
-                MTRR (Memory type range registers)
-                PGE (Page global enable)
-                MCA (Machine check architecture)
-                CMOV (Conditional move instruction supported)
-                PAT (Page attribute table)
-                PSE-36 (36-bit page size extension)
-                CLFSH (CLFLUSH instruction supported)
-                DS (Debug store)
-                ACPI (ACPI supported)
-                MMX (MMX technology supported)
-                FXSR (FXSAVE and FXSTOR instructions supported)
-                SSE (Streaming SIMD extensions)
-                SSE2 (Streaming SIMD extensions 2)
-                SS (Self-snoop)
-                HTT (Multi-threading)
-                TM (Thermal monitor supported)
-                PBE (Pending break enabled)
-        Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
-        Voltage: 1.6 V
-        External Clock: 100 MHz
-        Max Speed: 4000 MHz
-        Current Speed: 2500 MHz
-        Status: Populated, Enabled
-        Upgrade: Other
-        L1 Cache Handle: 0x004D
-        L2 Cache Handle: 0x004E
-        L3 Cache Handle: 0x004F
-        Serial Number: Not Specified
-        Asset Tag: UNKNOWN
-        Part Number: Not Specified
-        Core Count: 28
-        Core Enabled: 28
-        Thread Count: 56
-        Characteristics:
-                64-bit capable
-                Multi-Core
-                Hardware Thread
-                Execute Protection
-                Enhanced Virtualization
-                Power/Performance Control
-
-
-  Handle 0x0054, DMI type 4, 48 bytes
-  Processor Information
-        Socket Designation: CPU2
-        Type: Central Processor
-        Family: Xeon
-        Manufacturer: Intel(R) Corporation
-        ID: 54 06 05 00 FF FB EB BF
-        Signature: Type 0, Family 6, Model 85, Stepping 4
-        Flags:
-                FPU (Floating-point unit on-chip)
-                VME (Virtual mode extension)
-                DE (Debugging extension)
-                PSE (Page size extension)
-                TSC (Time stamp counter)
-                MSR (Model specific registers)
-                PAE (Physical address extension)
-                MCE (Machine check exception)
-                CX8 (CMPXCHG8 instruction supported)
-                APIC (On-chip APIC hardware supported)
-                SEP (Fast system call)
-                MTRR (Memory type range registers)
-                PGE (Page global enable)
-                MCA (Machine check architecture)
-                CMOV (Conditional move instruction supported)
-                PAT (Page attribute table)
-                PSE-36 (36-bit page size extension)
-                CLFSH (CLFLUSH instruction supported)
-                DS (Debug store)
-                ACPI (ACPI supported)
-                MMX (MMX technology supported)
-                FXSR (FXSAVE and FXSTOR instructions supported)
-                SSE (Streaming SIMD extensions)
-                SSE2 (Streaming SIMD extensions 2)
-                SS (Self-snoop)
-                HTT (Multi-threading)
-                TM (Thermal monitor supported)
-                PBE (Pending break enabled)
-        Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
-        Voltage: 1.6 V
-        External Clock: 100 MHz
-        Max Speed: 4000 MHz
-        Current Speed: 2500 MHz
-        Status: Populated, Enabled
-        Upgrade: Other
-        L1 Cache Handle: 0x0051
-        L2 Cache Handle: 0x0052
-        L3 Cache Handle: 0x0053
-        Serial Number: Not Specified
-        Asset Tag: UNKNOWN
-        Part Number: Not Specified
-        Core Count: 28
-        Core Enabled: 28
-        Thread Count: 56
-        Characteristics:
-                64-bit capable
-                Multi-Core
-                Hardware Thread
-                Execute Protection
-                Enhanced Virtualization
-                Power/Performance Control
-```
-
-### Xeon Skx Server Firmware Inventory
-
-```
-Host.           IPMI IP.      BIOS. CPLD.     Aptio SU.   CPU Microcode.  PCI Bus.   ME Operation FW.    X710 Firmware.            XXV710 Firmware.          i40e.
-s1-t11-sut1.    10.30.50.47.  2.1.  03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s2-t12-sut1.    10.30.50.48.  2.1.  03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s3-t21-sut1.    10.30.50.41.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s4-t21-tg1.     10.30.50.42.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s5-t22-sut1.    10.30.50.49.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s6-t22-tg1.     10.30.50.50.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s7-t23-sut1.    10.30.50.51.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s8-t23-tg1.     10.30.50.52.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s9-t24-sut1.    10.30.50.53.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s10-t24-tg1.    10.30.50.54.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s11-t31-sut1.   10.30.50.43.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s12-t31-sut2.   10.30.50.44.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s13-t31-tg1.    10.30.50.45.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s14-t32-sut1.   10.30.50.55.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s15-t32-sut2.   10.30.50.56.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s16-t32-tg1.    10.30.50.57.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-s19-t33t34-tg1. 10.30.50.46.  2.0b. 03.B1.03. 2.19.1268.  02000043.       A5.01.12.  4.0.4.294.          6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k.
-```