1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
- 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
- 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
- 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
- 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
- 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
+ 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
+ 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
+ 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
+ 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
+ 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
+ 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
+ 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
1. [Server Management](#server-management)
1. [Requirements](#requirements)
1. [Addressing](#addressing)
1. [Naming Convention](#naming-convention)
1. [Testbeds Configuration](#testbeds-configuration)
1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
- 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
- 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
- 1. [1-Node-Cascadelake (1n-clx) SETUP](#1-node-cascadelake-1n-clx-setup)
- 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
- 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
- 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
- 1. [2-Node-Cascadelake (2n-clx) SETUP](#2-node-cascadelake-2n-clx-setup)
- 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
- 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
- 1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
- 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
- 1. [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
+ 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
+ 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
+ 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
+ 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
+ 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
+ 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
+ 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
+ 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
+ 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
+ 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
+ 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
+ 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
+ 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
+ 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
1. [Per Testbed Wiring](#per-testbed-wiring)
- 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
- 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
- 1. [1-Node-Cascadelake (1n-clx) SETUP](#1-node-cascadelake-1n-clx-setup)
- 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
- 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
- 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
- 1. [2-Node-Cascadelake (2n-clx) SETUP](#2-node-cascadelake-2n-clx-setup)
- 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
- 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
- 1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
- 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
- 1. [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
+ 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
+ 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
+ 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
+ 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
+ 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
+ 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
+ 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
+ 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
+ 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
+ 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
+ 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
+ 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
+ 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
+ 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
1. [Inventory](#inventory)
1. [Appliances](#appliances)
1. [Arm Servers](#arm-servers)
### Summary List
```
- #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
- 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
- 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
- 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
- 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
- 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
- 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
- 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
- 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
- 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
-10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
-11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
-12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
-13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
-14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
- Totals: 22 35 18 12 19 1 2 3 1 2 2
+ #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
+ 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 0
+ 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 0
+ 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0
+ 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0
+ 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0 0
+ 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0 0
+ 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 0
+ 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0
+ 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0
+10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 0
+11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
+12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0
+13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0
+14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0
+15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0
+16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0
+17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0
+18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0
+19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2
+ Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
-Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
Used for FD.io VPP_Device functional driver tests.
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 2-Node-Denverton Atom Intel (2n-dnv)
Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
([Server Types](#server-types)).
Used for FD.io performance tests.
+### 2-Node-Zen2 EPYC AMD (2n-zn2)
+
+Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
+one TG (Server-Type-D2) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
+
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
+one TG (Server-Type-E31) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Icelake Xeon Intel (2n-icx)
+
+Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
+one TG (Server-Type-F2) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
### 3-Node-Haswell Xeon Intel (3n-hsw)
Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Skylake Xeon Intel (3n-skx)
+### 3-Node-Rangeley Atom Testbeds
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 3-Node-TaiShan Arm Huawei (3n-tsh)
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
-TG (Server-Type-B2) connected in a 3-node circular topology
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
+TG (Server-Type-E31) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-MACCHIATObin Arm Marvell
+### 3-Node-Altra Arm Ampere (3n-alt)
-Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
-one TG (Server-Type-B2) connected in a 3-node circular topology
+Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Rangeley Atom Testbeds
+### 3-Node-Icelake Xeon Intel (3n-icx)
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
+Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
+TG (Server-Type-F3) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-SnowRidge Atom Intel (3n-snr)
+
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
+
## Server Management
### Requirements
10.30.50.13 | LF Reserved
10.30.50.14 | LF Reserved
10.30.50.15 | LF Reserved
-10.30.50.16 | t1-tg1
-10.30.50.17 | t1-sut1
-10.30.50.18 | t1-sut2
-10.30.50.20 | t2-tg1
-10.30.50.21 | t2-sut1
-10.30.50.22 | t2-sut2
-10.30.50.24 | t3-tg1
-10.30.50.25 | t3-sut1
-10.30.50.26 | t3-sut-2
-10.30.50.28 | t4-sut1
-10.30.50.29 | t4-sut2
-10.30.50.30 | t4-sut3
+10.30.50.16 | s16-nomad
+10.30.50.17 | s17-nomad
+10.30.50.18 | s18-nomad
+10.30.50.19 | s19-nomad
+10.30.50.20 | s20-nomad
+10.30.50.21 | s21-nomad
+10.30.50.22 | s22-nomad
+10.30.50.23 | s23-nomad
+10.30.50.24 | s24-nomad
+10.30.50.25 | s25-nomad
+10.30.50.26 | s26-nomad
10.30.50.36 | s17-t33-sut1
10.30.50.37 | s18-t33-sut2
+10.30.50.38 | fdio-marvell-dev
10.30.50.41 | s3-t21-sut1
10.30.50.42 | s4-t21-tg1
10.30.50.43 | s11-t31-sut1
10.30.50.44 | s12-t31-sut2
10.30.50.45 | s13-t31-tg1
-10.30.50.46 | s19-t33t34-tg1
+10.30.50.46 | s19-t33t211-tg1
10.30.50.47 | s1-t11-sut1
10.30.50.48 | s2-t12-sut1
10.30.50.49 | s5-t22-sut1
10.30.50.57 | s16-t32-tg1
10.30.50.58 | s25-t25-sut1
10.30.50.59 | s26-t25-tg1
-10.30.50.69 | s27-t13-sut
-n/a | s20-t34-sut1
-n/a | s21-t34-sut2
-10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0
-10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1
-10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2
+10.30.50.69 | s27-t211-sut1
+10.30.50.70 | s55-t13-sut1
+10.30.50.71 | s56-t14-sut1
+10.30.50.72 | s62-t34-sut1
+10.30.50.73 | s63-t34-sut2
+10.30.50.74 | s64-t34-tg1
+10.30.50.75 | s65-t37-sut1
+10.30.50.76 | s66-t37-sut2
+10.30.50.77 | s67-t37-tg1
+10.30.50.78 | s78-t38-sut1
+10.30.50.79 | s79-t38-sut2
+10.30.50.80 | s80-t38-tg1
+10.30.50.81 | s71-t212-sut1
+10.30.50.82 | s72-t212-tg1
+10.30.50.83 | s83-t213-sut1
+10.30.50.84 | s84-t213-tg1
+10.30.50.85 | s85-t214-sut1
+10.30.50.86 | s86-t214-tg1
+10.30.50.87 | s87-t215-sut1
+10.30.50.88 | s88-t215-tg1
+10.30.50.89 | s89-t39t310-tg1
+10.30.50.90 | s90-t311t312-tg1
+10.30.50.91 | s91-nomad
+10.30.50.92 | s92-nomad
+10.30.50.93 | s93-t39-sut1
+10.30.50.94 | s94-t39-sut2
+10.30.50.255 | Broadcast
+10.30.55.0 | network
+10.30.55.1 | Router
10.30.55.10 | s28-t26t35-tg1
10.30.55.11 | s29-t26-sut1
10.30.55.12 | s30-t35-sut1
10.30.55.13 | s31-t35-sut2
-10.30.50.255 | Broadcast
-x.x.x.x | s32-t14-sut1
-x.x.x.x | s33-t27-sut1
-x.x.x.x | s34-t27-tg1
-x.x.x.x | s35-t28-sut1
-x.x.x.x | s36-t28-tg1
-x.x.x.x | s37-t29-sut1
-x.x.x.x | s38-t29-tg1
+10.30.55.18 | s33-t27-sut1
+10.30.55.19 | s34-t27-tg1
+10.30.55.20 | s35-t28-sut1
+10.30.55.21 | s36-t28-tg1
+10.30.55.22 | s37-t29-sut1
+10.30.55.23 | s38-t29-tg1
+10.30.55.24 | s60-t210-sut1
+10.30.55.25 | s61-t210-tg1
+10.30.55.255 | Broadcast
### Management VLAN IP Addresses
-Name | Comment
-------------------------- | -------
-10.30.51.0 | network
-10.30.51.1 | Router
-10.30.51.2 | LF Reserved
-10.30.51.3 | LF Reserved
-10.30.51.4 | LF Reserved
-10.30.51.5 | LF Reserved
-10.30.51.6 | LF Reserved
-10.30.51.7 | LF Reserved
-10.30.51.8 | LF Reserved
-10.30.51.9 | s22-t35-sut1 (netgate-1)
-10.30.51.10 | s23-t35-sut2 (netgate-2)
-10.30.51.11 | s24-t35-sut3 (netgate-3)
-10.30.51.12 | softiron-1
-10.30.51.13 | softiron-2
-10.30.51.14 | softiron-3
-10.30.51.15 | LF Reserved
-10.30.51.16 | t1-tg1
-10.30.51.17 | t1-sut1
-10.30.51.18 | t1-sut2
-10.30.51.20 | t2-tg1
-10.30.51.21 | t2-sut1
-10.30.51.22 | t2-sut2
-10.30.51.24 | t3-tg1
-10.30.51.25 | t3-sut1
-10.30.51.26 | t3-sut-2
-10.30.51.28 | t4-sut1
-10.30.51.29 | t4-sut2
-10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
-10.30.51.30 | t4-sut3
-10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
-10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
-10.30.51.36 | s17-t33-sut1
-10.30.51.37 | s18-t33-sut2
-10.30.51.41 | s20-t34-sut1
-10.30.51.42 | s21-t34-sut2
-10.30.51.44 | s3-t21-sut1
-10.30.51.45 | s4-t21-tg1
-10.30.51.46 | s11-t31-sut1
-10.30.51.47 | s12-t31-sut2
-10.30.51.48 | s13-t31-tg1
-10.30.51.49 | s19-t33t34-tg1
-10.30.51.50 | s1-t11-sut1
-10.30.51.51 | s2-t12-sut1
-10.30.51.52 | s5-t22-sut1
-10.30.51.53 | s6-t22-tg1
-10.30.51.54 | s7-t23-sut1
-10.30.51.55 | s8-t23-tg1
-10.30.51.56 | s9-t24-sut1
-10.30.51.57 | s10-t24-tg1
-10.30.51.58 | s14-t32-sut1
-10.30.51.59 | s15-t32-sut2
-10.30.51.60 | s16-t32-tg1
-10.30.51.61 | s25-t25-sut1
-10.30.51.62 | s26-t25-tg1
-10.30.51.69 | s27-t13-sut1
-10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED
-10.30.51.106-10.30.51.180 | VIRL2
-10.30.51.181-10.30.51.254 | VIRL3
-10.30.51.255 | Broadcast
-10.32.8.10 | s28-t26t35-tg1
-10.32.8.11 | s29-t26-sut1
-10.32.8.12 | s30-t35-sut1
-10.32.8.13 | s31-t35-sut2
-x.x.x.x | s32-t14-sut1
-x.x.x.x | s33-t27-sut1
-x.x.x.x | s34-t27-tg1
-x.x.x.x | s35-t28-sut1
-x.x.x.x | s36-t28-tg1
-x.x.x.x | s37-t29-sut1
-x.x.x.x | s38-t29-tg1
+Name | Comment
+-------------| -------
+10.30.51.0 | network
+10.30.51.1 | Router
+10.30.51.2 | LF Reserved
+10.30.51.3 | LF Reserved
+10.30.51.4 | LF Reserved
+10.30.51.5 | LF Reserved
+10.30.51.6 | LF Reserved
+10.30.51.7 | LF Reserved
+10.30.51.8 | LF Reserved
+10.30.51.15 | LF Reserved
+10.30.51.16 | s16-nomad
+10.30.51.17 | s17-nomad
+10.30.51.18 | s18-nomad
+10.30.51.19 | s19-nomad
+10.30.51.20 | s20-nomad
+10.30.51.21 | s21-nomad
+10.30.51.22 | s22-nomad
+10.30.51.23 | s23-nomad
+10.30.51.24 | s24-nomad
+10.30.51.25 | s25-nomad
+10.30.51.26 | s26-nomad
+10.30.51.36 | s17-t33-sut1
+10.30.51.37 | s18-t33-sut2
+10.30.51.38 | fdio-marvell-dev
+10.30.51.44 | s3-t21-sut1
+10.30.51.45 | s4-t21-tg1
+10.30.51.46 | s11-t31-sut1
+10.30.51.47 | s12-t31-sut2
+10.30.51.48 | s13-t31-tg1
+10.30.51.49 | s19-t33t211-tg1
+10.30.51.50 | s1-t11-sut1
+10.30.51.51 | s2-t12-sut1
+10.30.51.52 | s5-t22-sut1
+10.30.51.53 | s6-t22-tg1
+10.30.51.54 | s7-t23-sut1
+10.30.51.55 | s8-t23-tg1
+10.30.51.56 | s9-t24-sut1
+10.30.51.57 | s10-t24-tg1
+10.30.51.58 | s14-t32-sut1
+10.30.51.59 | s15-t32-sut2
+10.30.51.60 | s16-t32-tg1
+10.30.51.61 | s25-t25-sut1
+10.30.51.62 | s26-t25-tg1
+10.30.51.69 | s27-t211-sut1
+10.30.51.70 | s55-t13-sut1
+10.30.51.71 | s56-t14-sut1
+10.30.51.72 | s62-t34-sut1
+10.30.51.73 | s63-t34-sut2
+10.30.51.74 | s64-t34-tg1
+10.30.51.75 | s65-t37-sut1
+10.30.51.76 | s66-t37-sut2
+10.30.51.77 | s67-t37-tg1
+10.30.51.78 | s78-t38-sut1
+10.30.51.79 | s79-t38-sut2
+10.30.51.80 | s80-t38-tg1
+10.30.51.81 | s71-t212-sut1
+10.30.51.82 | s72-t212-tg1
+10.30.51.83 | s83-t213-sut1
+10.30.51.84 | s84-t213-tg1
+10.30.51.85 | s85-t214-sut1
+10.30.51.86 | s86-t214-tg1
+10.30.51.87 | s87-t215-sut1
+10.30.51.88 | s88-t215-tg1
+10.30.51.89 | s89-t39t310-tg1
+10.30.51.90 | s90-t311t312-tg1
+10.30.51.91 | s91-nomad
+10.30.51.92 | s92-nomad
+10.30.51.93 | s93-t39-sut1
+10.30.51.94 | s94-t39-sut2
+10.30.51.255 | Broadcast
+10.32.8.0 | network
+10.32.8.1 | Router
+10.32.8.10 | s28-t26t35-tg1
+10.32.8.11 | s29-t26-sut1
+10.32.8.12 | s30-t35-sut1
+10.32.8.13 | s31-t35-sut2
+10.32.8.18 | s33-t27-sut1
+10.32.8.19 | s34-t27-tg1
+10.32.8.20 | s35-t28-sut1
+10.32.8.21 | s36-t28-tg1
+10.32.8.22 | s37-t29-sut1
+10.32.8.23 | s38-t29-tg1
+10.32.8.24 | s60-t210-sut1
+10.32.8.25 | s61-t210-tg1
+10.32.8.255 | Broadcast
## Server Specifications
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- - PCIe Slot1: Cisco VIC 1385 2p40GE.
- - PCIe Slot2: Intel NIC x520 2p10GE.
+ - PCIe Slot1: empty.
+ - PCIe Slot2: empty.
- PCIe Slot3: empty.
- Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
+ - PCIe Slot4: empty.
+ - PCIe Slot5: empty.
+ - PCIe Slot6: empty
- MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
- Quantity: 3 servers.
- RAM Memory: 16* 32GB DDR4-2133MHz.
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- - PCIe Slot1: Intel NIC xl710 2p40GE.
- - PCIe Slot2: Intel NIC x710 2p10GE.
- - PCIe Slot3: Intel NIC x710 2p10GE.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel NIC x710 2p10GE.
+ - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
+ - PCIe Slot1: empty.
+ - PCIe Slot2: empty.
+ - PCIe Slot3: empty.
+ - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
+ - PCIe Slot4: empty.
+ - PCIe Slot5: empty.
+ - PCIe Slot6: empty
- MLOM slot: empty.
3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
- Quantity: 3 servers.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
+5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
- Quantity: ---
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI(?) and host management ports.
- - NIC ports connected into 3-node topology.
- - Main HW configuration:
- - Chassis: Huawei TaiShan 2280.
- - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
- - RAM Memory: 8* 16GB DDR4-2400MT/s
- - Disks: 1* 4TB SATA HDD
- - NICs configuration:
- - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-4. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
- - Quantity: 3
- - Physical connectivity:
- - Host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: MACCHIATObin.
- - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
- - RAM Memory: 1* 16GB DDR4
- - Disks: 1* 128GB(?) SATA SDD
- - NICs configuration:
- - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
+6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
- Quantity: TBD based on testbed allocation.
- Physical connectivity:
- Management: serial Port (usb) for console
- NICs configuration:
- 2x 10Gb Intel 82599ES
- 4x 1GB Intel I354
-6. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
+ - NIC ports connected into 1-node topologies.
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-7. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- Quantity: 1.
- Physical connectivity:
- Host management interface: 10/100/1000-BaseT.
- Port-2: 10GE SFP+.
- Port-3: 10GE SFP+.
- Port-4: 10GE SFP+.
-8. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-9. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- - Quantity: 1
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: Gigabyte R181-T90 1U
- - Motheboard: MT91-FS1
- - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - NICs configuration:
- - Numa0:
- - PCIe Slot1 05:00.xx: XL710-QDA2.
- - PCIe Slot3 08:00.xx: XL710-QDA2.
- - Numa1:
- - PCIe Slot6 85:00.xx: XL710-QDA2.
10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
- Quantity: 4
- Physical connectivity:
- 2x 10Gb Intel x553 fiber ports
- 2x 10Gb Intel x553 copper ports
- 4x 1GB Intel I350 ports
-
-6. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-
-4. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
+ - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
- PCIe Slot10 d8:00.xx: empty.
-
-3. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- - CIMC and host management ports.
+ - IPMI and host management ports.
- no NIC ports, standalone setup.
- Main HW configuration:
- Chassis: SuperMicro 1029P-WTRT.
- no cards.
- Numa1:
- no cards.
+15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro AS-1114S-WTRT
+ - Processors: 1* AMD EPYC 7532 2.4 GHz.
+ - RAM Memory: 8* 32GB DDR4-2933.
+ - Disks: 1* 1TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
+ - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro AS-1114S-WTRT
+ - Processors: 1* AMD EPYC 7532 2.4 GHz.
+ - RAM Memory: 8* 32GB DDR4-2933.
+ - Disks: 1* 1TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+ - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
+ - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
+17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: GIGABYTE Rack Mount
+ - Motherboard: MT91-FS4-00
+ - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
+ - RAM Memory: 16 * 16GB DIMM
+ - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
+ - Numa1:
+ - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI(?) and host management ports.
+ - NIC ports connected into 3-node topology.
+ - Main HW configuration:
+ - Chassis: Huawei TaiShan 2280.
+ - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
+ - RAM Memory: 8* 16GB DDR4-2400MT/s
+ - Disks: 1* 4TB SATA HDD
+ - NICs configuration:
+ - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
+ - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
+19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node topologies.
+ - Main HW configuration:
+ - Chassis: Gigabyte R181-T90 1U
+ - Motherboard: MT91-FS1
+ - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
+ - RAM Memory: 4* 32GB RDIMM
+ - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
+ - NICs configuration:
+ - Numa0:
+ - no cards
+ - Numa1:
+ - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
+20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node topologies.
+ - Main HW configuration:
+ - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+ - Motherboard: Mt.Jade Motherboard
+ - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+ - RAM Memory: 16* 8GB DDR4-3200MT/s
+ - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
+ - Numa1:
+ - no cards.
+21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - Main HW configuration:
+ - Chassis: Gigabyte R152-P30-00 1U
+ - Motherboard: MP32-AR1-00
+ - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+ - RAM Memory: 12* 16GB DDR4-3200MT/s
+ - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+ - Quantity: 8.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and/or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 d8:00.xx: empty.
+27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topology.
+ - Main HW configuration:
+ - Chassis: Intel JACOBSVILLE SDP.
+ - Motherboard: Intel JACOBSVILLE E63448-400.
+ - Processors: 1* Intel Atom P5362B 2.2 GHz.
+ - RAM Memory: 2* 16GB DDR4-2933.
+ - Disks: ?* ? SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, PCIe3.0 lane)
+ - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
```
### Naming Convention
### Per Testbed Server Allocation and Naming
-#### 1-Node-Skylake (1n-skx) PROD
+#### 1-Node-Skylake Servers (1n-skx) PROD
```
- SUT [Server-Type-B6]:
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 1-Node-Thunderx2 (1n-tx2) WIP
+#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
```
-- SUT [Server-Type-B9]:
- - testbedname: testbed13.
- - hostname: s27-t13-sut1.
- - IPMI IP: 10.30.50.69
- - Host IP: 10.30.51.69
+- SUT [Server-Type-E11]:
+ - testbedname: testbed13
+ - hostname: s55-t13-sut1
+ - IPMI IP: 10.30.50.70
+ - Host IP: 10.30.51.70
+ - portnames:
+ - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+- SUT [Server-Type-E11]:
+ - testbedname: testbed14
+ - hostname: s56-t14-sut1
+ - IPMI IP: 10.30.50.71
+ - Host IP: 10.30.51.71
- portnames:
- - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+ - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
```
-#### 1-Node-Cascadelake (1n-clx) SETUP
+#### 1-Node-Cascadelake Servers (1n-clx) PROD
```
- SUT [Server-Type-C1]:
- testbedname: testbed11.
- hostname: s32-t14-sut1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.17
+ - Host IP: 10.32.8.17
- portnames:
- s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-Skylake (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
- - testbedname: testbed21.
- - hostname: s3-t21-sut1.
- - IPMI IP: 10.30.50.41
- - Host IP: 10.30.51.44
- - portnames:
- - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed21.
- - hostname: s4-t21-tg1.
- - IPMI IP: 10.30.50.42
- - Host IP: 10.30.51.45
- - portnames:
- - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed22.
- - hostname: s5-t22-sut1.
- - IPMI IP: 10.30.50.49
- - Host IP: 10.30.51.52
- - portnames:
- - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed22.
- - hostname: s6-t22-tg1.
- - IPMI IP: 10.30.50.50
- - Host IP: 10.30.51.53
- - portnames:
- - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed23.
- - hostname: s7-t23-sut1.
- - IPMI IP: 10.30.50.51
- - Host IP: 10.30.51.54
- - portnames:
- - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed23.
- - hostname: s8-t23-tg1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.55
- - portnames:
- - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed24.
- - hostname: s9-t24-sut1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.56
- - portnames:
- - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed24.
- - hostname: s10-t24-tg1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.57
- - portnames:
- - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 2-Node-Denverton (2n-dnv) WIP
+#### 2-Node-Denverton Servers (2n-dnv) PROD
Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
```
-#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
```
- SUT [Server-Type-B8]:
- s26-t25-tg1-p4 - 10GE-port4.
```
-#### 2-Node-Cascadelake (2n-clx) SETUP
+#### 2-Node-Cascadelake Servers (2n-clx) PROD
```
- SUT [Server-Type-C2]:
- testbedname: testbed27.
- hostname: s33-t27-sut1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.18
+ - Host IP: 10.32.8.18
- portnames:
- s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed27.
- hostname: s34-t27-tg1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.19
+ - Host IP: 10.32.8.19
- portnames:
- s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- testbedname: testbed28.
- hostname: s35-t28-sut1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.20
+ - Host IP: 10.32.8.20
- portnames:
- s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed28.
- hostname: s36-t28-tg1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.21
+ - Host IP: 10.32.8.21
- portnames:
- s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- testbedname: testbed29.
- hostname: s37-t29-sut1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.22
+ - Host IP: 10.32.8.22
- portnames:
- s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+ - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed29.
- hostname: s38-t29-tg1.
- - IPMI IP: x.x.x.x
- - Host IP: x.x.x.x
+ - IPMI IP: 10.30.55.23
+ - Host IP: 10.32.8.23
- portnames:
- s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+ - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
```
-#### 3-Node-Haswell (3n-hsw) PROD
+#### 2-Node-Zen2 Servers (2n-zn2) PROD
```
- 1. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut1.
- - CIMC IP: 10.30.50.17
- - Host IP: 10.30.51.17
- - portnames:
- - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut2.
- - CIMC IP: 10.30.50.18
- - Host IP: 10.30.51.18
+- SUT [Server-Type-D1]:
+ - testbedname: testbed210.
+ - hostname: s60-t210-sut1.
+ - IPMI IP: 10.30.55.24
+ - Host IP: 10.32.8.24
- portnames:
- - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. TG [Server-Type-A2]:
- - testbedname: testbed1.
- - hostname: t1-tg1.
- - CIMC IP: 10.30.50.16
- - Host IP: 10.30.51.16
+ - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
+ - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
+ - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
+ - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
+ - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-D2]:
+ - testbedname: testbed210.
+ - hostname: s61-t210-tg1.
+ - IPMI IP: 10.30.55.25
+ - Host IP: 10.32.8.25
- portnames:
- - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut1.
- - CIMC IP: 10.30.50.21
- - Host IP: 10.30.51.21
- - portnames:
- - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut2.
- - CIMC IP: 10.30.50.22
- - Host IP: 10.30.51.22
- - portnames:
- - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. TG [Server-Type-A2]:
- - testbedname: testbed2.
- - hostname: t2-tg1.
- - CIMC IP: 10.30.50.20
- - Host IP: 10.30.51.20
+ - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+```
+
+#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
+
+Note: Server19 (TG) is shared between testbed33 & testbed211
+
+```
+- SUT [Server-Type-E22]:
+ - testbedname: testbed211.
+ - hostname: s27-t211-sut1.
+ - IPMI IP: 10.30.50.69
+ - Host IP: 10.30.51.69
- portnames:
- - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut1.
- - CIMC IP: 10.30.50.25
- - Host IP: 10.30.51.25
+ - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+- TG [Server-Type-E31]:
+ - testbedname: testbed33 and testbed211.
+ - hostname: s19-t33t211-tg1.
+ - IPMI IP: 10.30.50.46
+ - Host IP: 10.30.51.49
- portnames:
- - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut2.
- - CIMC IP: 10.30.50.26
- - Host IP: 10.30.51.26
+ - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 2-Node-Icelake Servers (2n-icx) PROD
+
+```
+- SUT [Server-Type-F1]:
+ - testbedname: testbed212.
+ - hostname: s71-t212-sut1.
+ - IPMI IP: 10.30.51.81
+ - Host IP: 10.30.50.81
- portnames:
- - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. TG [Server-Type-A2]:
- - testbedname: testbed3.
- - hostname: t3-tg1.
- - CIMC IP: 10.30.50.24
- - Host IP: 10.30.51.24
+ - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed212.
+ - hostname: s72-t212-tg1.
+ - IPMI IP: 10.30.51.82
+ - Host IP: 10.30.50.82
- portnames:
- - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-```
-
-#### 3-Node-Skylake (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s11-t31-sut1.
- - IPMI IP: 10.30.50.43
- - Host IP: 10.30.51.46
+ - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed213.
+ - hostname: s83-t213-sut1.
+ - IPMI IP: 10.30.51.83
+ - Host IP: 10.30.50.83
- portnames:
- - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB12 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s12-t31-sut2.
- - IPMI IP: 10.30.50.44
- - Host IP: 10.30.51.47
+ - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed213.
+ - hostname: s84-t213-tg1.
+ - IPMI IP: 10.30.51.84
+ - Host IP: 10.30.50.84
- portnames:
- - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB13 [Server-Type-B2]:
- - testbedname: testbed31.
- - hostname: s13-t31-tg1.
- - IPMI IP: 10.30.50.45
- - Host IP: 10.30.51.48
+ - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed214.
+ - hostname: s85-t214-sut1.
+ - IPMI IP: 10.30.51.85
+ - Host IP: 10.30.50.85
- portnames:
- - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB14 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s14-t32-sut1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.58
+ - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed214.
+ - hostname: s86-t214-tg1.
+ - IPMI IP: 10.30.51.86
+ - Host IP: 10.30.50.86
- portnames:
- - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB15 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s15-t32-sut2.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.59
+ - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+ - testbedname: testbed215.
+ - hostname: s87-t215-sut1.
+ - IPMI IP: 10.30.51.87
+ - Host IP: 10.30.50.87
- portnames:
- - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB16 [Server-Type-B2]:
- - testbedname: testbed32.
- - hostname: s16-t32-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.60
+ - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+ - testbedname: testbed215.
+ - hostname: s88-t215-tg1.
+ - IPMI IP: 10.30.51.88
+ - Host IP: 10.30.50.88
- portnames:
- - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+ - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-Rangeley (3n-rng) VERIFY
+#### 3-Node-Rangeley Servers (3n-rng) VERIFY
Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- 1GB ports (tbd)
```
-#### 3-Node-Taishan (3n-tsh) WIP
+#### 3-Node-Taishan Servers (3n-tsh) PROD
-Note: ServerB19 (TG) is shared between testbed33 & testbed34
+Note: Server19 (TG) is shared between testbed33 & testbed211
```
-- ServerB17 [Server-Type-B3]:
+- SUT [Server-Type-E21]:
- testbedname: testbed33.
- hostname: s17-t33-sut1.
- IPMI IP: 10.30.50.36
- s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB18 [Server-Type-B3]:
+- SUT [Server-Type-E21]:
- testbedname: testbed33.
- hostname: s18-t33-sut2.
- IPMI IP: 10.30.50.37
- s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB19 [Server-Type-B2]:
- - testbednames: testbed33 and testbed34.
- - hostname: s19-t33t34-tg1.
+- TG [Server-Type-E31]:
+ - testbedname: testbed33 and testbed211.
+ - hostname: s19-t33t211-tg1.
- IPMI IP: 10.30.50.46
- Host IP: 10.30.51.49
- portnames:
- - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB20 [Server-Type-B4]:
+ - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 3-Node-Altra Servers (3n-alt) PROD
+
+```
+- SUT [Server-Type-E23]:
+ - testbedname: testbed34.
+ - hostname: s62-t34-sut1.
+ - IPMI IP: 10.30.50.72
+ - Host IP: 10.30.51.72
+ - portnames:
+ - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- SUT [Server-Type-E23]:
- testbedname: testbed34.
- - hostname: s20-t34-sut1.
- - IPMI IP: N/A
- - Host IP: 10.30.51.41
+ - hostname: s63-t34-sut2.
+ - IPMI IP: 10.30.50.73
+ - Host IP: 10.30.51.73
- portnames:
- - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
- - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
-- ServerB21 [Server-Type-B4]:
+ - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- TG [Server-Type-F4]:
- testbedname: testbed34.
- - hostname: s21-t34-sut2.
- - IPMI IP: N/A
- - Host IP: 10.30.51.42
+ - hostname: s64-t34-tg1.
+ - IPMI IP: 10.30.50.74
+ - Host IP: 10.30.51.74
- portnames:
- - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
- - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
+ - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-Denverton (3n-dnv) WIP
+#### 3-Node-Denverton Servers (3n-dnv) PROD
```
- ServerB30 [Server-Type-B10]:
- s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
```
-#### 3-Node-Mcbin (3n-mcb) TODO
+#### 3-Node-Icelake Servers (3n-icx) PROD
```
-To be completed.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed37.
+ - hostname: s65-t37-sut1.
+ - IPMI IP: 10.30.50.75
+ - Host IP: 10.30.51.75
+ - portnames:
+ - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed37.
+ - hostname: s66-t37-sut2.
+ - IPMI IP: 10.30.50.76
+ - Host IP: 10.30.51.76
+ - portnames:
+ - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+ - testbedname: testbed37.
+ - hostname: s67-t37-tg1.
+ - IPMI IP: 10.30.50.77
+ - Host IP: 10.30.51.77
+ - portnames:
+ - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed38.
+ - hostname: s78-t38-sut1.
+ - IPMI IP: 10.30.50.78
+ - Host IP: 10.30.51.78
+ - portnames:
+ - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+ - testbedname: testbed38.
+ - hostname: s79-t38-sut2.
+ - IPMI IP: 10.30.50.79
+ - Host IP: 10.30.51.79
+ - portnames:
+ - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+ - testbedname: testbed38.
+ - hostname: s80-t38-tg1.
+ - IPMI IP: 10.30.50.80
+ - Host IP: 10.30.51.80
+ - portnames:
+ - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-SnowRidge Servers (3n-snr) PROD
+
+```
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s93-t39-sut1.
+ - IPMI IP: 10.30.50.93
+ - Host IP: 10.30.51.93
+ - portnames:
+ - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s94-t39-sut2.
+ - IPMI IP: 10.30.50.94
+ - Host IP: 10.30.51.94
+ - portnames:
+ - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+ - testbedname: testbed39.
+ - hostname: s89-t39t310-tg1.
+ - IPMI IP: 10.30.50.89
+ - Host IP: 10.30.51.89
+ - portnames:
+ - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
```
### Per Testbed Wiring
-#### 1-Node-Skylake (1n-skx) PROD
+#### 1-Node-Skylake Wiring (1n-skx) PROD
```
- testbed11:
- ring3 10GE-ports x710-4p10GE:
- s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
- ring4 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+ - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
+ - ring5 100GE-ports e810-2p100GE:
+ - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
+ - ring6 100GE-ports e810-2p100GE:
+ - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
- testbed12:
- ring1 10GE-ports x710-4p10GE:
- s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
- ring3 10GE-ports x710-4p10GE:
- s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
- ring4 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+ - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
+ - ring5 100GE-ports e810-2p100GE:
+ - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
+ - ring6 100GE-ports e810-2p100GE:
+ - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
```
-#### 1-Node-Thunderx2 (1n-tx2) WIP
+#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
```
- testbed13:
- ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
+ - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
- ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
- - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
-```
+ - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
+ - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
+ - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
-#### 1-Node-Cascadelake (1n-clx) SETUP
-
-```
- testbed14:
- - ring1 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
-```
-
-#### 2-Node-Skylake (2n-skx) PROD
-
-```
-- testbed21:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
- - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
- - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-- testbed22:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
- - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
- - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-- testbed23:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
- - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
- - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-- testbed24:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
- - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
- - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
+ - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
+ - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
+ - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
+ - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+ - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
-#### 2-Node-Denverton (2n-dnv) WIP
+#### 2-Node-Denverton Wiring (2n-dnv) PROD
```
- testbed26:
- s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
```
-#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
```
- testbed25:
- t25-tg1-p4 to t25-sut1-c2/p4.
```
-#### 2-Node-Cascadelake (2n-clx) SETUP
+#### 2-Node-Cascadelake Wiring (2n-clx) PROD
```
- testbed27:
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+ - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
+ - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+ - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
- testbed28:
- ring1 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
- s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+ - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
+ - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+ - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
- testbed29:
- ring1 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
- s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+ - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
+ - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
```
-#### 3-Node-Haswell (3n-hsw) PROD
-
-```
- 1. testbed1:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t1-tg1-c1/p1 to t1-sut1-c1/p2.
- - t1-sut1-c1/p1 to t1-sut2-c1/p2.
- - t1-sut2-c1/p1 to t1-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-c2/p2.
- - t1-sut1-c2/p1 to t1-sut2-c2/p2.
- - t1-sut2-c2/p1 to t1-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t1-tg1-c4/p1 to t1-sut1-c4/p2.
- - t1-sut1-c4/p1 to t1-sut2-c4/p2.
- - t1-sut2-c4/p1 to t1-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t1-tg1-c5/p1 to t1-sut1-c5/p2.
- - t1-sut1-c5/p1 to t1-sut2-c5/p2.
- - t1-sut2-c5/p1 to t1-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-cm/p2.
- - t1-sut1-cm/p1 to t1-sut2-cm/p2.
- - t1-sut2-cm/p1 to t1-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t2-tg1-c1/p1 to t2-sut1-c1/p2.
- - t2-sut1-c1/p1 to t2-sut2-c1/p2.
- - t2-sut2-c1/p1 to t2-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-c2/p2.
- - t2-sut1-c2/p1 to t2-sut2-c2/p2.
- - t2-sut2-c2/p1 to t2-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t2-tg1-c4/p1 to t2-sut1-c4/p2.
- - t2-sut1-c4/p1 to t2-sut2-c4/p2.
- - t2-sut2-c4/p1 to t2-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t2-tg1-c5/p1 to t2-sut1-c5/p2.
- - t2-sut1-c5/p1 to t2-sut2-c5/p2.
- - t2-sut2-c5/p1 to t2-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-cm/p2.
- - t2-sut1-cm/p1 to t2-sut2-cm/p2.
- - t2-sut2-cm/p1 to t2-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t3-tg1-c1/p1 to t3-sut1-c1/p2.
- - t3-sut1-c1/p1 to t3-sut2-c1/p2.
- - t3-sut2-c1/p1 to t3-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-c2/p2.
- - t3-sut1-c2/p1 to t3-sut2-c2/p2.
- - t3-sut2-c2/p1 to t3-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t3-tg1-c4/p1 to t3-sut1-c4/p2.
- - t3-sut1-c4/p1 to t3-sut2-c4/p2.
- - t3-sut2-c4/p1 to t3-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t3-tg1-c5/p1 to t3-sut1-c5/p2.
- - t3-sut1-c5/p1 to t3-sut2-c5/p2.
- - t3-sut2-c5/p1 to t3-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-cm/p2.
- - t3-sut1-cm/p1 to t3-sut2-cm/p2.
- - t3-sut2-cm/p1 to t3-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
-#### 3-Node-Skylake (3n-skx) PROD
-
-```
-- testbed31:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
- - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
- - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
- - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
- - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
- - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
- - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
- - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
- - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
- - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
- - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
- - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
+#### 2-Node-Zen2 Wiring (2n-zn2) PROD
+
+```
+- testbed210:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
+ - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
- ring2 10GE-ports x710-4p10GE on SUT:
- - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
- - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
- - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
+ - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
+ - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
- - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
- - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
- - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
- - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
- - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
+ - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
+ - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
+ - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
-#### 3-Node-Rangeley (3n-rng) TODO
+#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
+
+```
+- testbed211:
+ - ring1 10GE-ports x520-2p10GE on SUTs:
+ - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
+ - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
+```
+
+#### 2-Node-Icelake Wiring (2n-icx) PROD
+
+```
+- testbed212:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
+ - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
+ - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
+ - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
+ - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
+ - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
+ - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
+- testbed213:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+ - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+ - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+ - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+ - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+ - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+ - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
+- testbed214:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+ - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+ - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+ - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+ - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+ - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+ - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
+- testbed215:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+ - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+ - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+ - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+ - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+ - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+ - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
+ - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+ - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+ - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
+```
+
+#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
```
To be completed.
```
-#### 3-Node-Taishan (3n-tsh) WIP
+#### 3-Node-Taishan Wiring (3n-tsh) PROD
```
- testbed33:
- ring1 10GE-ports x520-2p10GE on SUTs:
- - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
- - t33-sut1-c6/p1 - t33-sut2-c6/p2.
- - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
+ - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
+ - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
+ - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
- ring2 25GE-ports cx4-2p25GE on SUTs:
- - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
- - t33-sut1-c4/p1 - t33-sut2-c4/p2.
- - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
+ - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
+ - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
+ - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
```
-#### 3-Node-Mcbin (3n-mcb) WIP
+#### 3-Node-Altra Wiring (3n-alt) PROD
```
- testbed34:
- - ring1 10GE-ports Marvell on SUTs:
- - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
- - t34-sut1-ca/p2 - t34-sut2-ca/p1.
- - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
+ - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
+ - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+ - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+ - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
```
-#### 3-Node-Denverton (3n-dnv) WIP
+#### 3-Node-Denverton Wiring (3n-dnv) PROD
```
- testbed35:
- s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
```
+#### 3-Node-Icelake Wiring (3n-icx) PROD
+
+```
+- testbed37:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+ - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
+ - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
+ - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+ - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
+ - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
+ - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
+ - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
+ - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
+ - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+ - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
+ - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
+ - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
+- testbed38:
+ - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+ - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+ - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+ - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
+ - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+ - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+ - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+ - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+ - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+ - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+ - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
+ - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+ - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+ - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+ - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+
+```
+- testbed39:
+ - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+ - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+ - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+ - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+ - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+ - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+ - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
+```
+
## Inventory
### Appliances
- Operating System: Native IxOS.
```
-### Arm Servers
+### Arm Servers
```
1. Arm Cortex A-72 servers
- - 1 * ThunderX2
- - Chassis: Marvell ThunderX2
- - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
+ - 2 * ThunderX2 (VPP Device)
+ - Chassis: GIGABYTE Rack Mount
+ - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
+ - RAM Memory: 16* 16GB DIMM
+ - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
+ - 1 * ThunderX2 (Performance)
+ - Chassis: GIGABYTE Rack Mount
+ - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
- RAM Memory: 4* 32GB RDIMM
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- 2 * Huawei TaiShan 2280.
- Chassis: Huawei TaiShan 2280.
- - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
+ - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
- RAM Memory: 8* 16GB DDR4-2400MT/s.
- Disks: 1* 4TB SATA HDD.
- - 3 * MACCHIATObin
- - Chassis: MACCHIATObin.
- - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
- - RAM Memory: 1* 16GB DDR4.
- - Disks: 1* 128GB(?) SATA SDD.
+2. Arm Neoverse N1 servers
+ - 2 * Ampere Altra (Performance)
+ - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+ - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+ - RAM Memory: 16* 8GB DDR4-3200MT/s
+ - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+ - 2 * Ampere Altra (Build)
+ - Chassis: Gigabyte R152-P30-00 1U
+ - Motherboard: MP32-AR1-00
+ - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+ - RAM Memory: 12* 16GB DDR4-3200MT/s
+ - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
```
### Xeon and Atom Servers
```
1. 10GE NICs
- - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
- - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
- - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+ - ?
2. 25GE NICs
- - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+ - ?
3. 40GE NICs
- - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+ - ?
4. 100GE NICs
- - 4 * mcx556a-edat NICs (not on site yet, in transit)
+ - ?
```
### Pluggables and Cables
```
1. 10GE SFP+
- - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
- - 80 * 10G SR optic (generic, "Intel" compatible branded)
+ - ?
2. 25GE SFP28
- - None
+ - ?
3. 40GE QSFP+
- - None
+ - ?
4. 100GE
- - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+ - ?
```
Standalone cables:
```
1. 10GE
- - None
+ - ?
2. 25GE
- - None
+ - ?
3. 40GE QSFP+
- - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+ - ?
4. 100GE
- - None
+ - ?
```
### Other Parts