1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
+ 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
1. [Testbeds Configuration](#testbeds-configuration)
1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
- 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
+ 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
- 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
- 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
+ 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
+ 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
+ 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
- 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-wip)
+ 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
1. [Per Testbed Wiring](#per-testbed-wiring)
1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
- 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
- 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
+ 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
+ 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
- 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
+ 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
+ 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
- 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-wip)
+ 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
1. [Inventory](#inventory)
1. [Appliances](#appliances)
1. [Arm Servers](#arm-servers)
#. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
- 3. 1-Node-Thunderx2 idle tx2 na 1 1 0 0 0 0 0 0 1 0 0 0
- 4. 1-Node-Thunderx2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
+ 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
+ 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
- Totals: 27 36 16.5 12 18.5 1 2 3 3 2 7 2
+ Totals: 27 36 18 12 19 1 2 3 3 2 7 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
([Server Types](#server-types)).
Used for FD.io performance tests.
+### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
+
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
+one TG (Server-Type-B12) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
### 3-Node-Haswell Xeon Intel (3n-hsw)
Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
### 3-Node-TaiShan Arm Huawei (3n-tsh)
Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
-TG (Server-Type-B2) connected in a 3-node circular topology
+TG (Server-Type-B12) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
10.30.50.30 | s40-nomad
10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
-10.30.50.32 | s42-nomad (formerly nomad1)
-10.30.50.33 | s43-nomad (formerly nomad2)
-10.30.50.34 | s44-nomad (formerly nomad3)
-10.30.50.35 | s45-nomad (formerly nomad4)
+10.30.50.32 | s42-nomad
+10.30.50.33 | s43-nomad
+10.30.50.34 | s44-nomad
+10.30.50.35 | s45-nomad
10.30.50.36 | s17-t33-sut1
10.30.50.37 | s18-t33-sut2
10.30.50.38 | fdio-marvell-dev
10.30.50.66 | s51-nomad
10.30.50.67 | s49-nomad
10.30.50.68 | s50-nomad
-10.30.50.69 | s27-t13-sut
+10.30.50.69 | s27-t34-sut1
10.30.50.70 | s55-t36-sut1
10.30.50.71 | s56-t37-sut1
10.30.50.255 | Broadcast
10.30.55.11 | s29-t26-sut1
10.30.55.12 | s30-t35-sut1
10.30.55.13 | s31-t35-sut2
-10.30.55.14 | s46-nomad (formerly server-type-c4-1)
-10.30.55.15 | s47-nomad (formerly server-type-c4-2)
-10.30.55.16 | s48-nomad (formerly server-type-c4-3)
-10.30.55.17 | s32-t14-sut1
+10.30.55.14 | s46-nomad
+10.30.55.15 | s47-nomad
+10.30.55.16 | s48-nomad
+10.30.55.17 | s57-nomad
10.30.55.18 | s33-t27-sut1
10.30.55.19 | s34-t27-tg1
10.30.55.20 | s35-t28-sut1
10.30.51.28 | s41-nomad
10.30.51.29 | s39-nomad
10.30.51.30 | s40-nomad
-10.30.51.32 | s42-nomad (formerly nomad1)
-10.30.51.33 | s43-nomad (formerly nomad2)
-10.30.51.34 | s44-nomad (formerly nomad3)
-10.30.51.35 | s45-nomad (formerly nomad4)
+10.30.51.32 | s42-nomad
+10.30.51.33 | s43-nomad
+10.30.51.34 | s44-nomad
+10.30.51.35 | s45-nomad
10.30.51.36 | s17-t33-sut1
10.30.51.37 | s18-t33-sut2
10.30.51.38 | fdio-marvell-dev
10.30.51.66 | s51-nomad
10.30.51.67 | s49-nomad
10.30.51.68 | s50-nomad
-10.30.51.69 | s27-t13-sut1
+10.30.51.69 | s27-t34-sut1
10.30.51.70 | s55-t36-sut1
10.30.51.71 | s56-t37-sut1
10.30.51.72-10.30.51.105 | FREE
10.32.8.11 | s29-t26-sut1
10.32.8.12 | s30-t35-sut1
10.32.8.13 | s31-t35-sut2
-10.32.8.14 | s46-nomad (formerly server-type-c4-1)
-10.32.8.15 | s47-nomad (formerly server-type-c4-2)
-10.32.8.16 | s48-nomad (formerly server-type-c4-3)
-10.32.8.17 | s32-t14-sut1
+10.32.8.14 | s46-nomad
+10.32.8.15 | s47-nomad
+10.32.8.16 | s48-nomad
+10.32.8.17 | s57-nomad
10.32.8.18 | s33-t27-sut1
10.32.8.19 | s34-t27-tg1
10.32.8.20 | s35-t28-sut1
- NIC ports connected into 3-node topology.
- Main HW configuration:
- Chassis: Huawei TaiShan 2280.
- - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
+ - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
- RAM Memory: 8* 16GB DDR4-2400MT/s
- Disks: 1* 4TB SATA HDD
- NICs configuration:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle).
+11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- Quantity: 1
- Physical connectivity:
- IPMI and host management ports.
- Main HW configuration:
- Chassis: Gigabyte R181-T90 1U
- Motherboard: MT91-FS1
- - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
+ - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- RAM Memory: 4* 32GB RDIMM
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- NICs configuration:
- Numa0:
- - PCIe Slot1 05:00.xx: XL710-QDA2.
- - PCIe Slot3 08:00.xx: XL710-QDA2.
+ - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
- Numa1:
- - PCIe Slot6 85:00.xx: XL710-QDA2.
+ - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
- Quantity: 4
- Physical connectivity:
- 2x 10Gb Intel x553 fiber ports
- 2x 10Gb Intel x553 copper ports
- 4x 1GB Intel I350 ports
-13. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
- Main HW configuration:
- Chassis: GIGABYTE Rack Mount
- Motherboard: MT91-FS4-00
- - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz
+ - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
- RAM Memory: 16 * 16GB DIMM
- Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
- NICs configuration:
- Numa1:
- PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - Quantity: ---
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+ - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- CIMC and host management ports.
- Numa1:
- no cards.
-18. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-19. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 1-Node-Thunderx2 Servers (1n-tx2) WIP
+#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
```
- SUT [Server-Type-B11]:
- s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-
- SUT [Server-Type-B11]:
- testbedname: testbed37
- hostname: s56-t37-sut1
- s26-t25-tg1-p4 - 10GE-port4.
```
-#### 2-Node-Cascadelake Servers (2n-clx) SETUP
+#### 2-Node-Cascadelake Servers (2n-clx) PROD
```
- SUT [Server-Type-C2]:
- s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
- s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
- s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+ - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- TG [Server-Type-C3]:
- testbedname: testbed29.
- hostname: s38-t29-tg1.
- s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+ - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
```
-#### 2-Node-Zen2 Servers (2n-zn2) SETUP
+#### 2-Node-Zen2 Servers (2n-zn2) PROD
```
- SUT [Server-Type-D1]:
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
+#### 2-Node-ThunderX2 Servers (2x-tx2) WIP
+
+Note: Server19 (TG) is shared between testbed33 & testbed34
+
+```
+- SUT [Server-Type-B9]:
+ - testbedname: testbed34.
+ - hostname: s27-t34-sut1.
+ - IPMI IP: 10.30.50.69
+ - Host IP: 10.30.51.69
+ - portnames:
+ - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
+- TG [Server-Type-B12]:
+ - testbedname: testbed33 and testbed34.
+ - hostname: s19-t33t34-tg1.
+ - IPMI IP: 10.30.50.46
+ - Host IP: 10.30.51.49
+ - portnames:
+ - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
#### 3-Node-Haswell Servers (3n-hsw) PROD
```
#### 3-Node-Taishan Servers (3n-tsh) PROD
+Note: Server19 (TG) is shared between testbed33 & testbed34
+
```
-- ServerB17 [Server-Type-B3]:
+- SUT [Server-Type-B3]:
- testbedname: testbed33.
- hostname: s17-t33-sut1.
- IPMI IP: 10.30.50.36
- s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB18 [Server-Type-B3]:
+- SUT [Server-Type-B3]:
- testbedname: testbed33.
- hostname: s18-t33-sut2.
- IPMI IP: 10.30.50.37
- s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB19 [Server-Type-B2]:
+- TG [Server-Type-B12]:
- testbedname: testbed33 and testbed34.
- hostname: s19-t33t34-tg1.
- IPMI IP: 10.30.50.46
- s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
- s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
```
-#### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
+#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
```
- testbed36:
- s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
```
-#### 1-Node-Cascadelake Wiring (1n-clx) SETUP
+#### 1-Node-Cascadelake Wiring (1n-clx) PROD
```
- testbed14:
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT:
+ - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
+ - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
- testbed28:
- ring1 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
- s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
+ - ring5 100GE-ports e810-2p100GE on SUT:
+ - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
+ - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
- testbed29:
- ring1 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
- s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
+ - ring6 100GE-ports e810-2p100GE on SUT:
+ - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
+ - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
```
-#### 2-Node-Zen2 Wiring (2n-zen2) SETUP
+#### 2-Node-Zen2 Wiring (2n-zn2) PROD
```
- testbed210:
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
+#### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
+
+```
+- testbed34:
+ - ring1 10GE-ports x520-2p10GE on SUTs:
+ - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
+ - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
+```
+
+
#### 3-Node-Haswell Wiring (3n-hsw) PROD
```
1. Arm Cortex A-72 servers
- 2 * ThunderX2 (VPP Device)
- Chassis: GIGABYTE Rack Mount
- - Processors: 2* ThunderX2 CN9980 ~ 128* ThunderX2
+ - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
- RAM Memory: 16* 16GB DIMM
- Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - 1 * ThunderX2 (Idle)
- - Chassis: Marvell ThunderX2
- - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
+ - 1 * ThunderX2 (Performance)
+ - Chassis: GIGABYTE Rack Mount
+ - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
- RAM Memory: 4* 32GB RDIMM
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- 2 * Huawei TaiShan 2280.
- Chassis: Huawei TaiShan 2280.
- - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
+ - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
- RAM Memory: 8* 16GB DDR4-2400MT/s.
- Disks: 1* 4TB SATA HDD.
```