1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
+ 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
1. [Server Management](#server-management)
1. [Requirements](#requirements)
1. [Addressing](#addressing)
1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
- 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
+ 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
- 1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd)
- 1. [3-Node-Icelake Servers (3n-icx) TBD](#3-node-icelake-servers-3n-icx-tbd)
+ 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
+ 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
+ 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
1. [Per Testbed Wiring](#per-testbed-wiring)
1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
- 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
+ 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
- 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
+ 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
- 1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd)
- 1. [3-Node-Icelake Wiring (3n-icx) TBD](#3-node-icelake-wiring-3n-icx-tbd)
+ 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
+ 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
+ 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
1. [Inventory](#inventory)
1. [Appliances](#appliances)
1. [Arm Servers](#arm-servers)
### Summary List
```
- #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx
- 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0
- 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0
- 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
- 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0
- 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 0
- 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0
- 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0
- 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0
- 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0
-10. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8
-11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0
-12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0
-13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0
-14. 3-Node-Altra perf alt icx 1 2 .5 0 0 0 0 0 0 0 2 0 0 .5
-15. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0
-16. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0
-17. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 6
-18. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0
- Totals: 34 43 21.5 4 19 1 2 3 3 2 4 7 2 14.5
+ #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
+ 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 0
+ 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 0
+ 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0
+ 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0
+ 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0 0
+ 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0 0
+ 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 0
+ 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0
+ 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0
+10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 0
+11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
+12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0
+13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0
+14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0
+15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0
+16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0
+17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0
+18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0
+19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2
+ Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
([Server Types](#server-types)).
Used for FD.io performance tests.
+### 3-Node-SnowRidge Atom Intel (3n-snr)
+
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+
## Server Management
### Requirements
10.30.50.71 | s56-t14-sut1
10.30.50.72 | s62-t34-sut1
10.30.50.73 | s63-t34-sut2
-10.30.50.74 | s64-t34t36-tg1
+10.30.50.74 | s64-t34-tg1
10.30.50.75 | s65-t37-sut1
10.30.50.76 | s66-t37-sut2
10.30.50.77 | s67-t37-tg1
-10.30.50.78 | s68-t38-sut1
-10.30.50.79 | s69-t38-sut2
-10.30.50.80 | s70-t38-tg1
+10.30.50.78 | s78-t38-sut1
+10.30.50.79 | s79-t38-sut2
+10.30.50.80 | s80-t38-tg1
10.30.50.81 | s71-t212-sut1
10.30.50.82 | s72-t212-tg1
-10.30.50.83 | s73-t213-sut1
-10.30.50.84 | s74-t213-tg1
-10.30.50.85 | s75-t214-sut1
-10.30.50.86 | s76-t214-tg1
-10.30.50.87 | s77-t215-sut1
-10.30.50.88 | s78-t215-tg1
-10.30.50.89 | s79-t39t310-tg1
-10.30.50.90 | s80-t311t312-tg1
+10.30.50.83 | s83-t213-sut1
+10.30.50.84 | s84-t213-tg1
+10.30.50.85 | s85-t214-sut1
+10.30.50.86 | s86-t214-tg1
+10.30.50.87 | s87-t215-sut1
+10.30.50.88 | s88-t215-tg1
+10.30.50.89 | s89-t39t310-tg1
+10.30.50.90 | s90-t311t312-tg1
10.30.50.91 | s58-nomad
10.30.50.92 | s59-nomad
+10.30.50.93 | s93-t39-sut1
+10.30.50.94 | s94-t39-sut2
10.30.50.255 | Broadcast
10.30.55.0 | network
10.30.55.1 | Router
10.30.51.71 | s56-t14-sut1
10.30.51.72 | s62-t34-sut1
10.30.51.73 | s63-t34-sut2
-10.30.51.74 | s64-t34t36-tg1
+10.30.51.74 | s64-t34-tg1
10.30.51.75 | s65-t37-sut1
10.30.51.76 | s66-t37-sut2
10.30.51.77 | s67-t37-tg1
-10.30.51.78 | s68-t38-sut1
-10.30.51.79 | s69-t38-sut2
-10.30.51.80 | s70-t38-tg1
+10.30.51.78 | s78-t38-sut1
+10.30.51.79 | s79-t38-sut2
+10.30.51.80 | s80-t38-tg1
10.30.51.81 | s71-t212-sut1
10.30.51.82 | s72-t212-tg1
-10.30.51.83 | s73-t213-sut1
-10.30.51.84 | s74-t213-tg1
-10.30.51.85 | s75-t214-sut1
-10.30.51.86 | s76-t214-tg1
-10.30.51.87 | s77-t215-sut1
-10.30.51.88 | s78-t215-tg1
-10.30.51.89 | s79-t39t310-tg1
-10.30.51.90 | s80-t311t312-tg1
+10.30.51.83 | s83-t213-sut1
+10.30.51.84 | s84-t213-tg1
+10.30.51.85 | s85-t214-sut1
+10.30.51.86 | s86-t214-tg1
+10.30.51.87 | s87-t215-sut1
+10.30.51.88 | s88-t215-tg1
+10.30.51.89 | s89-t39t310-tg1
+10.30.51.90 | s90-t311t312-tg1
10.30.51.91 | s58-nomad
10.30.51.92 | s59-nomad
+10.30.51.93 | s93-t39-sut1
+10.30.51.94 | s94-t39-sut2
10.30.51.255 | Broadcast
10.32.8.0 | network
10.32.8.1 | Router
- Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- NICs configuration:
- Numa0:
- - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
+ - no cards
- Numa1:
- PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- - Quantity: 1
+ - Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node topologies.
- Main HW configuration:
- - Chassis: TBD
- - Motherboard: TBD
- - Processors: n* TBD
- - RAM Memory: n* TBD
- - Disks: TBD
+ - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+ - Motherboard: Mt.Jade Motherboard
+ - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+ - RAM Memory: 16* 8GB DDR4-3200MT/s
+ - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
- NICs configuration:
- Numa0:
- - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+ - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
- Numa1:
- - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-21. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - no cards.
+21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - Main HW configuration:
+ - Chassis: Gigabyte R152-P30-00 1U
+ - Motherboard: MP32-AR1-00
+ - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+ - RAM Memory: 12* 16GB DDR4-3200MT/s
+ - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
- Quantity: 1
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
- Quantity: 8.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
- PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 d8:00.xx: empty.
-26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
- - Quantity: 2.
+27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+ - Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
+ - NIC ports connected into 3-node testbed topology.
- Main HW configuration:
- - Chassis: Gigabyte R152-P30-00 1U
- - Motherboard: MP32-AR1-00
- - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1)
- - RAM Memory: 4* 16GB RDIMM-3200MHz
- - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+ - Chassis: Intel JACOBSVILLE SDP.
+ - Motherboard: Intel JACOBSVILLE E63448-400.
+ - Processors: 1* Intel Atom P5362B 2.2 GHz.
+ - RAM Memory: 2* 16GB DDR4-2933.
+ - Disks: ?* ? SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, PCIe3.0 lane)
+ - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
```
### Naming Convention
- IPMI IP: 10.30.50.69
- Host IP: 10.30.51.69
- portnames:
- - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- TG [Server-Type-E31]:
- s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-Icelake Servers (2n-icx) TBD
+#### 2-Node-Icelake Servers (2n-icx) PROD
```
- SUT [Server-Type-F1]:
- s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- SUT [Server-Type-F1]:
- testbedname: testbed213.
- - hostname: s73-t213-sut1.
+ - hostname: s83-t213-sut1.
- IPMI IP: 10.30.51.83
- Host IP: 10.30.50.83
- portnames:
- - s73-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s73-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s73-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s73-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s73-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s73-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s73-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s73-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- TG [Server-Type-F2]:
- testbedname: testbed213.
- - hostname: s74-t213-tg1.
+ - hostname: s84-t213-tg1.
- IPMI IP: 10.30.51.84
- Host IP: 10.30.50.84
- portnames:
- - s74-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s74-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s74-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s74-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s74-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s74-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s74-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s74-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s74-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s74-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- SUT [Server-Type-F1]:
- testbedname: testbed214.
- - hostname: s75-t214-sut1.
+ - hostname: s85-t214-sut1.
- IPMI IP: 10.30.51.85
- Host IP: 10.30.50.85
- portnames:
- - s75-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s75-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s75-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s75-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s75-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s75-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s75-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s75-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- TG [Server-Type-F2]:
- testbedname: testbed214.
- - hostname: s76-t214-tg1.
+ - hostname: s86-t214-tg1.
- IPMI IP: 10.30.51.86
- Host IP: 10.30.50.86
- portnames:
- - s76-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s76-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s76-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s76-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s76-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s76-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s76-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s76-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s76-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s76-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- SUT [Server-Type-F1]:
- testbedname: testbed215.
- - hostname: s77-t215-sut1.
+ - hostname: s87-t215-sut1.
- IPMI IP: 10.30.51.87
- Host IP: 10.30.50.87
- portnames:
- - s77-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s77-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s77-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s77-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s77-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s77-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s77-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s77-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- TG [Server-Type-F2]:
- testbedname: testbed215.
- - hostname: s78-t215-tg1.
+ - hostname: s88-t215-tg1.
- IPMI IP: 10.30.51.88
- Host IP: 10.30.50.88
- portnames:
- - s78-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s78-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s78-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s78-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s78-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s78-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s78-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s78-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s78-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s78-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
#### 3-Node-Skylake Servers (3n-skx) PROD
- s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Altra Servers (3n-alt) TBD
-
-Note: Server64 (TG) is shared between testbed34 & testbed36
+#### 3-Node-Altra Servers (3n-alt) PROD
```
- SUT [Server-Type-E23]:
- IPMI IP: 10.30.50.72
- Host IP: 10.30.51.72
- portnames:
- - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
+ - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- SUT [Server-Type-E23]:
- testbedname: testbed34.
- hostname: s63-t34-sut2.
- IPMI IP: 10.30.50.73
- Host IP: 10.30.51.73
- portnames:
- - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
+ - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
- TG [Server-Type-F4]:
- testbedname: testbed34.
- - hostname: s64-t34t36-tg1.
+ - hostname: s64-t34-tg1.
- IPMI IP: 10.30.50.74
- Host IP: 10.30.51.74
- portnames:
- - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
#### 3-Node-Denverton Servers (3n-dnv) PROD
- s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
```
-#### 3-Node-Icelake Servers (3n-icx) TBD
+#### 3-Node-Icelake Servers (3n-icx) PROD
```
- ServerF1 [Server-Type-F1]:
- s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- ServerF1 [Server-Type-F1]:
- testbedname: testbed38.
- - hostname: s68-t38-sut1.
+ - hostname: s78-t38-sut1.
- IPMI IP: 10.30.50.78
- Host IP: 10.30.51.78
- portnames:
- - s68-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s68-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s68-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s68-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s68-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s68-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s68-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s68-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- ServerF1 [Server-Type-F1]:
- testbedname: testbed38.
- - hostname: s69-t38-sut2.
+ - hostname: s79-t38-sut2.
- IPMI IP: 10.30.50.79
- Host IP: 10.30.51.79
- portnames:
- - s69-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s69-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s69-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s69-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s69-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s69-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s69-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s69-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- ServerF3 [Server-Type-F3]:
- testbedname: testbed38.
- - hostname: s70-t38-tg1.
+ - hostname: s80-t38-tg1.
- IPMI IP: 10.30.50.80
- Host IP: 10.30.51.80
- portnames:
- - s70-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s70-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s70-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
- - s70-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- - s70-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- - s70-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
- - s70-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s70-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+ - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+ - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+ - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-SnowRidge Servers (3n-snr) PROD
+
+```
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s93-t39-sut1.
+ - IPMI IP: 10.30.50.93
+ - Host IP: 10.30.51.93
+ - portnames:
+ - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+ - testbedname: testbed39.
+ - hostname: s94-t39-sut2.
+ - IPMI IP: 10.30.50.94
+ - Host IP: 10.30.51.94
+ - portnames:
+ - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+ - testbedname: testbed39.
+ - hostname: s89-t39t310-tg1.
+ - IPMI IP: 10.30.50.89
+ - Host IP: 10.30.51.89
+ - portnames:
+ - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+ - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
```
### Per Testbed Wiring
- s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
```
-#### 2-Node-Icelake Wiring (2n-icx) TBD
+#### 2-Node-Icelake Wiring (2n-icx) PROD
```
- testbed212:
- s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
- testbed213:
- ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s74-t213-tg1-c2/p1 to s73-t213-sut1-c2/p1.
- - s73-t213-sut1-c2/p2 to s74-t213-tg1-c2/p2.
+ - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+ - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s74-t213-tg1-c4/p1 to s73-t213-sut1-c4/p1.
- - s73-t213-sut1-c4/p2 to s74-t213-tg1-c4/p2.
- - s74-t213-tg1-c4/p3 to s73-t213-sut1-c4/p3.
- - s73-t213-sut1-c4/p4 to s74-t213-tg1-c4/p4.
+ - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+ - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+ - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+ - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s74-t213-tg1-c9/p1 to s73-t213-sut1-c9/p1.
- - s73-t213-sut1-c9/p2 to s74-t213-tg1-c9/p2.
+ - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+ - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s74-t213-tg1-c6/p1 to s74-t213-tg1-c6/p2.
- - s74-t213-tg1-c6/p2 to s74-t213-tg1-c6/p1.
+ - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+ - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
- testbed214:
- ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s76-t214-tg1-c2/p1 to s75-t214-sut1-c2/p1.
- - s75-t214-sut1-c2/p2 to s76-t214-tg1-c2/p2.
+ - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+ - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s76-t214-tg1-c4/p1 to s75-t214-sut1-c4/p1.
- - s75-t214-sut1-c4/p2 to s76-t214-tg1-c4/p2.
- - s76-t214-tg1-c4/p3 to s75-t214-sut1-c4/p3.
- - s75-t214-sut1-c4/p4 to s76-t214-tg1-c4/p4.
+ - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+ - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+ - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+ - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s76-t214-tg1-c9/p1 to s75-t214-sut1-c9/p1.
- - s75-t214-sut1-c9/p2 to s76-t214-tg1-c9/p2.
+ - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+ - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s76-t214-tg1-c6/p1 to s76-t214-tg1-c6/p2.
- - s76-t214-tg1-c6/p2 to s76-t214-tg1-c6/p1.
+ - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+ - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
- testbed215:
- ring1 25GE-ports xxv710-DA2-2p25GE on SUT
- - s78-t215-tg1-c2/p1 to s77-t215-sut1-c2/p1.
- - s77-t215-sut1-c2/p2 to s78-t215-tg1-c2/p2.
+ - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+ - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
- - s78-t215-tg1-c4/p1 to s77-t215-sut1-c4/p1.
- - s77-t215-sut1-c4/p2 to s78-t215-tg1-c4/p2.
- - s78-t215-tg1-c4/p3 to s77-t215-sut1-c4/p3.
- - s77-t215-sut1-c4/p4 to s78-t215-tg1-c4/p4.
+ - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+ - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+ - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+ - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s78-t215-tg1-c9/p1 to s77-t215-sut1-c9/p1.
- - s77-t215-sut1-c9/p2 to s78-t215-tg1-c9/p2.
+ - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+ - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
- ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
- - s78-t215-tg1-c6/p1 to s78-t215-tg1-c6/p2.
- - s78-t215-tg1-c6/p2 to s78-t215-tg1-c6/p1.
+ - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+ - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
```
#### 3-Node-Skylake Wiring (3n-skx) PROD
- s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
```
-#### 3-Node-Rangeley Wiring (3n-rng) TODO
+#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
```
To be completed.
- s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
```
-#### 3-Node-Altra Wiring (3n-alt) TBD
+#### 3-Node-Altra Wiring (3n-alt) PROD
```
- testbed34:
- ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
- - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
- - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
- - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
- - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
- - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
- - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
- - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
+ - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+ - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+ - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
```
#### 3-Node-Denverton Wiring (3n-dnv) PROD
- s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
- testbed38:
- ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
- - s70-t38-tg1-c2/p1 to s68-t38-sut1-c2/p1.
- - s68-t38-sut1-c2/p2 to s69-t38-sut2-c2/p2.
- - s69-t38-sut2-c2/p1 to s70-t38-tg1-c2/p2.
+ - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+ - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+ - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
- ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
- - s70-t38-tg1-c4/p1 to s68-t38-sut1-c4/p1.
- - s68-t38-sut1-c4/p2 to s69-t38-sut2-c4/p2.
- - s69-t38-sut2-c4/p1 to s70-t38-tg1-c4/p2.
- - s70-t38-tg1-c4/p3 to s68-t38-sut1-c4/p3.
- - s68-t38-sut1-c4/p4 to s69-t38-sut2-c4/p4.
- - s69-t38-sut2-c4/p3 to s70-t38-tg1-c4/p4.
+ - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+ - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+ - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+ - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+ - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+ - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
- ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
- - s70-t38-tg1-c9/p1 to s68-t38-sut1-c9/p1.
- - s68-t38-sut1-c9/p2 to s69-t38-sut2-c9/p2.
- - s69-t38-sut2-c9/p1 to s70-t38-tg1-c9/p2.
+ - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+ - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+ - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+
+```
+- testbed39:
+ - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+ - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+ - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+ - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+ - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+ - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+ - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
```
## Inventory
- Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
- RAM Memory: 8* 16GB DDR4-2400MT/s.
- Disks: 1* 4TB SATA HDD.
- - 2 * Ampere Altra
- - Chassis: TBD
- - Processors: TBD
- - RAM Memory: TBD
- - Disks: TBD
+2. Arm Neoverse N1 servers
+ - 2 * Ampere Altra (Performance)
+ - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+ - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+ - RAM Memory: 16* 8GB DDR4-3200MT/s
+ - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+ - 2 * Ampere Altra (Build)
+ - Chassis: Gigabyte R152-P30-00 1U
+ - Motherboard: MP32-AR1-00
+ - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+ - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+ - RAM Memory: 12* 16GB DDR4-3200MT/s
+ - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
```
### Xeon and Atom Servers
```
1. 10GE NICs
- - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
- - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
- - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+ - ?
2. 25GE NICs
- - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+ - ?
3. 40GE NICs
- - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+ - ?
4. 100GE NICs
- - 4 * mcx556a-edat NICs (not on site yet, in transit)
+ - ?
```
### Pluggables and Cables
```
1. 10GE SFP+
- - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
- - 80 * 10G SR optic (generic, "Intel" compatible branded)
+ - ?
2. 25GE SFP28
- - None
+ - ?
3. 40GE QSFP+
- - None
+ - ?
4. 100GE
- - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+ - ?
```
Standalone cables:
```
1. 10GE
- - None
+ - ?
2. 25GE
- - None
+ - ?
3. 40GE QSFP+
- - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+ - ?
4. 100GE
- - None
+ - ?
```
### Other Parts