docs/lab: merged testbed specifications, separated out detailed HW and BIOS configs.
[csit.git] / docs / lab / testbeds_ucs_hsw_hw_bios_cfg.md
similarity index 53%
rename from docs/lab/Testbeds_Xeon_Hsw_VIRL.md
rename to docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md
index 5ec6b59..ed4b1f5 100644 (file)
-## FD.io CSIT Testbeds - Xeon Haswell
+<!-- TOC depthFrom:1 depthTo:6 withLinks:1 updateOnSave:1 orderedList:0 -->
 
-This is a low-level design implemented as an original FD.io CSIT lab based on
-Cisco UCS-c240m4 servers based on Intel Xeon Haswell processors.
+       - [Cisco UCS c240m4 Xeon Haswell Servers - Hardware and BIOS Configuration](#cisco-ucs-c240m4-xeon-haswell-servers-hardware-and-bios-configuration)
+               - [Linux lscpu](#linux-lscpu)
+               - [Linux dmidecode pci](#linux-dmidecode-pci)
+               - [Linux dmidecode memory](#linux-dmidecode-memory)
+               - [Xeon Hsw Server BIOS Configuration](#xeon-hsw-server-bios-configuration)
 
-### Server Hardware Configuration
+<!-- /TOC -->
 
-Total of 10 Cisco UCS-c240 servers with Intel Xeon Haswell processors have been
-used to built FD.io CSIT 3-Node Haswell (3n-hsw) performance testbeds and VIRL
-functional testbeds. Following three HW configuration types of UCS x86 servers
-are used:
-
-```
- 1. Type-1: Purpose - VPP functional and performance conformance testing.
-    - Quantity: 6 computers as SUT hosts (Systems Under Test).
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - NIC ports connected in 3-node topologies.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-    - NICs configuration:
-        - Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
-            - PCIe Slot1: Cisco VIC 1385 2p40GE.
-            - PCIe Slot2: Intel NIC x520 2p10GE.
-            - PCIe Slot3: empty.
-        - Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
-            - PCIe Slot4: Intel NIC xl710 2p40GE.
-            - PCIe Slot5: Intel NIC x710 2p10GE.
-            - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
-        - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
- 2. Type-2: Purpose - VPP functional and performance conformance testing.
-    - Quantity: 3 computers as TG hosts (Traffic Generators).
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - NIC ports connected in 3-node topologies.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-    - NICs configuration:
-        - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-            - PCIe Slot1: Intel NIC xl710 2p40GE.
-            - PCIe Slot2: Intel NIC x710 2p10GE.
-            - PCIe Slot3: Intel NIC x710 2p10GE.
-        - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-            - PCIe Slot4: Intel NIC xl710 2p40GE.
-            - PCIe Slot5: Intel NIC x710 2p10GE.
-            - PCIe Slot6: Intel NIC x710 2p10GE.
-        - MLOM slot: empty.
- 3. Type-3: Purpose - VIRL functional conformance.
-    - Quantity: 3 computers as VIRL hosts.
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - no NIC ports, standalone setup.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
-    - NICs configuration:
-        - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-            - no cards.
-        - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-            - no cards.
-        - MLOM slot: empty.
-```
-
-## Testbeds1,2,3 Connectivity
-
-### Management Ports
-
-Total of 10 UCSC-C240-M4SX servers is made available for FD.IO CSIT testbed. For
-management purposes, each server must have following two ports connected to the
-management network:
-
-```
- 1. 1GE CIMC port
-    - CIMC - Cisco Integrated Management Controller.
-    - Required for provides embedded server management with WebUI, CLI, SNMPv3,
-      IPMIv2.0.
- 2. 1GE management port
-    - hostOS management port.
-```
-
-### Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
- - testbedname: testbedN.
- - hostname:
-    - traffic-generator: tN-tgW.
-    - system-under-testX: tN-sutX.
- - portnames:
-    - tN-tgW-cY/pZ.
-    - tN-sutX-cY/pZ.
- - where:
-    - N - testbed number.
-    - tgW - server acts as traffic-generator with W index.
-    - sutX - server acts as system-under-test with X index.
-    - Y - PCIe slot number denoting a NIC card number within the host.
-        - Y=1,2,3 - slots in Riser 1, Right PCIe Riser Board, NUMA node 0.
-        - Y=4,5,6 - slots in Riser 2, Left PCIe Riser Board, NUMA node 1.
-        - Y=m - the MLOM slot.
-    - Z - port number on the NIC card.
-```
-
-### 3-node Topology Testbeds for Performance
-
-Nine servers are used to build three of 3-node topologies, with each topology
-using two servers of Type-1 (SUT function) and one server of Type-2
-(TG function). Server NIC cards are placed and NIC ports are connected using the
-scheme defined in next sections.
-
-### LOM (CIMC) and Management networks
-
-Each server has a LOM (Lights-Out-Management e.g. Cisco CIMC) and a Management
-port, which are connected to two different VLANs.
-
-```
- 1. LOM (CIMC) VLAN:
-    - Subnet: 10.30.50.0/24
-    - Gateway: 10.30.50.1
-    - Broadcast: 10.30.50.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
- 2. Management Vlan:
-    - Subnet: 10.30.51.0/24
-    - Gateway: 10.30.51.1
-    - Broadcast: 10.30.51.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
-```
-To access these hosts, an VPN connection is required.
-
-#### LOM (CIMC) VLAN IP Addresses allocation
-
-Name | Comment
----- | -------
-10.30.50.0 | network
-10.30.51.1 | Router
-10.30.50.2 | LF Reserved
-10.30.50.3 | LF Reserved
-10.30.50.4 | LF Reserved
-10.30.50.5 | LF Reserved
-10.30.50.6 | LF Reserved
-10.30.50.7 | LF Reserved
-10.30.50.8 | LF Reserved
-10.30.50.9 | LF Reserved
-10.30.50.10 | LF Reserved
-10.30.50.11 | LF Reserved
-10.30.50.12 | LF Reserved
-10.30.50.13 | LF Reserved
-10.30.50.14 | LF Reserved
-10.30.50.15 | LF Reserved
-10.30.50.16 | t1-tg1
-10.30.50.17 | t1-sut1
-10.30.50.18 | t1-sut2
-10.30.50.20 | t2-tg1
-10.30.50.21 | t2-sut1
-10.30.50.22 | t2-sut2
-10.30.50.24 | t3-tg1
-10.30.50.25 | t3-sut1
-10.30.50.26 | t3-sut-2
-10.30.50.28 | t4-sut1
-10.30.50.29 | t4-sut2
-10.30.50.30 | t4-sut3
-10.30.50.255 | Broadcast
-
-#### Management VLAN IP Addresses allocation
-
-Name | Comment
----- | -------
-10.30.51.0 | network
-10.30.51.1 | Router
-10.30.51.2 | LF Reserved
-10.30.51.3 | LF Reserved
-10.30.51.4 | LF Reserved
-10.30.51.5 | LF Reserved
-10.30.51.6 | LF Reserved
-10.30.51.7 | LF Reserved
-10.30.51.8 | LF Reserved
-10.30.51.9 | netgate-1
-10.30.51.10 | netgate-2
-10.30.51.11 | netgate-3
-10.30.51.12 | softiron-1
-10.30.51.13 | softiron-2
-10.30.51.14 | softiron-3
-10.30.51.15 | LF Reserved
-10.30.51.16 | t1-tg1
-10.30.51.17 | t1-sut1
-10.30.51.18 | t1-sut2
-10.30.51.20 | t2-tg1
-10.30.51.21 | t2-sut1
-10.30.51.22 | t2-sut2
-10.30.51.24 | t3-tg1
-10.30.51.25 | t3-sut1
-10.30.51.26 | t3-sut-2
-10.30.51.28 | t4-sut1
-10.30.51.29 | t4-sut2
-10.30.51.30 | t4-sut3
-10.30.51.31-10.30.51.105 | VIRL1
-10.30.51.106-10.30.51.180 | VIRL2
-10.30.51.181-10.30.51.254 | VIRL3
-10.30.51.255 | Broadcast
-
-### Testbeds1,2,3 Naming: Servers, Ports
-
-Each server in 3-node Topology has its NIC cards placed, and NIC cards and ports
-indexed using defined naming convention:
-
-```
- 1. Server1 of Type-1:
-    - testbedname: testbed1.
-    - hostname: t1-sut1.
-    - CIMC IP: 10.30.50.17
-    - Host IP: 10.30.51.17
-    - portnames:
-        - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. Server2 of Type-1:
-    - testbedname: testbed1.
-    - hostname: t1-sut2.
-    - CIMC IP: 10.30.50.18
-    - Host IP: 10.30.51.18
-    - portnames:
-        - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. Server3 of Type-2:
-    - testbedname: testbed1.
-    - hostname: t1-tg1.
-    - CIMC IP: 10.30.50.16
-    - Host IP: 10.30.51.16
-    - portnames:
-        - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. Server4 of Type-1:
-    - testbedname: testbed2.
-    - hostname: t2-sut1.
-    - CIMC IP: 10.30.50.21
-    - Host IP: 10.30.51.21
-    - portnames:
-        - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. Server5 of Type-1:
-    - testbedname: testbed2.
-    - hostname: t2-sut2.
-    - CIMC IP: 10.30.50.22
-    - Host IP: 10.30.51.22
-    - portnames:
-        - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. Server6 of Type-2:
-    - testbedname: testbed2.
-    - hostname: t2-tg1.
-    - CIMC IP: 10.30.50.20
-    - Host IP: 10.30.51.20
-    - portnames:
-        - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. Server7 of Type-1:
-    - testbedname: testbed3.
-    - hostname: t3-sut1.
-    - CIMC IP: 10.30.50.25
-    - Host IP: 10.30.51.25
-    - portnames:
-        - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. Server8 of Type-1:
-    - testbedname: testbed3.
-    - hostname: t3-sut2.
-    - CIMC IP: 10.30.50.26
-    - Host IP: 10.30.51.26
-    - portnames:
-        - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. Server9 of Type-2:
-    - testbedname: testbed3.
-    - hostname: t3-tg1.
-    - CIMC IP: 10.30.50.24
-    - Host IP: 10.30.51.24
-    - portnames:
-        - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-```
-
-### Testbeds1,2,3 Network Connectivity
-
-Listed nine servers are connected into the three of 3-node testbeds, testbed1,
-testbed2 and testbed3, using defined naming convention as follows:
-
-```
- 1. testbed1:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t1-tg1-c1/p1 to t1-sut1-c1/p2.
-        - t1-sut1-c1/p1 to t1-sut2-c1/p2.
-        - t1-sut2-c1/p1 to t1-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t1-tg1-c2/p1 to t1-sut1-c2/p2.
-        - t1-sut1-c2/p1 to t1-sut2-c2/p2.
-        - t1-sut2-c2/p1 to t1-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t1-tg1-c4/p1 to t1-sut1-c4/p2.
-        - t1-sut1-c4/p1 to t1-sut2-c4/p2.
-        - t1-sut2-c4/p1 to t1-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t1-tg1-c5/p1 to t1-sut1-c5/p2.
-        - t1-sut1-c5/p1 to t1-sut2-c5/p2.
-        - t1-sut2-c5/p1 to t1-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t1-tg1-c2/p1 to t1-sut1-cm/p2.
-        - t1-sut1-cm/p1 to t1-sut2-cm/p2.
-        - t1-sut2-cm/p1 to t1-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t2-tg1-c1/p1 to t2-sut1-c1/p2.
-        - t2-sut1-c1/p1 to t2-sut2-c1/p2.
-        - t2-sut2-c1/p1 to t2-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t2-tg1-c2/p1 to t2-sut1-c2/p2.
-        - t2-sut1-c2/p1 to t2-sut2-c2/p2.
-        - t2-sut2-c2/p1 to t2-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t2-tg1-c4/p1 to t2-sut1-c4/p2.
-        - t2-sut1-c4/p1 to t2-sut2-c4/p2.
-        - t2-sut2-c4/p1 to t2-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t2-tg1-c5/p1 to t2-sut1-c5/p2.
-        - t2-sut1-c5/p1 to t2-sut2-c5/p2.
-        - t2-sut2-c5/p1 to t2-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t2-tg1-c2/p1 to t2-sut1-cm/p2.
-        - t2-sut1-cm/p1 to t2-sut2-cm/p2.
-        - t2-sut2-cm/p1 to t2-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t3-tg1-c1/p1 to t3-sut1-c1/p2.
-        - t3-sut1-c1/p1 to t3-sut2-c1/p2.
-        - t3-sut2-c1/p1 to t3-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t3-tg1-c2/p1 to t3-sut1-c2/p2.
-        - t3-sut1-c2/p1 to t3-sut2-c2/p2.
-        - t3-sut2-c2/p1 to t3-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t3-tg1-c4/p1 to t3-sut1-c4/p2.
-        - t3-sut1-c4/p1 to t3-sut2-c4/p2.
-        - t3-sut2-c4/p1 to t3-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t3-tg1-c5/p1 to t3-sut1-c5/p2.
-        - t3-sut1-c5/p1 to t3-sut2-c5/p2.
-        - t3-sut2-c5/p1 to t3-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t3-tg1-c2/p1 to t3-sut1-cm/p2.
-        - t3-sut1-cm/p1 to t3-sut2-cm/p2.
-        - t3-sut2-cm/p1 to t3-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
-## Testbeds1,2,3 Server Specifications
+## Cisco UCS c240m4 Xeon Haswell Servers - Hardware and BIOS Configuration
 
 ### Linux lscpu
 
@@ -1181,4 +743,3 @@ testbed2 and testbed3, using defined naming convention as follows:
     Out-of-Band Management: Disabled
  C240-FCH1950V1H5 /bios/advanced #
 ```
-