-CSIT Release Notes\r
-==================\r
-\r
-Changes in CSIT |release|\r
--------------------------\r
-\r
-#. VPP performance test environment changes\r
-\r
- - Further optimizations of VM and vhost-user test environment - various\r
- Qemu virtio queue size testing with value of 256 and 1024. Applied\r
- Linux CFS optimization to run VPP worker threads and Qemu worker threads\r
- with highest priority.\r
-\r
-#. VPP performance test framework changes\r
-\r
- - Full code review, optimization and refactor.\r
-\r
-#. T-rex changes\r
-\r
- - Full refactor of T-rex driver and introduce of traffic profiles that\r
- improves readability, manageability of traffic profiles for various\r
- test scenarios.\r
-\r
-#. Added VPP performance tests\r
-\r
- - **LXC memif**\r
-\r
- - Memif interface tests interconnecting two VPP instances on single SUT.\r
- Master VPP instance running on native OS with Intel x520 NIC and guest\r
- VPP instance running in Linux Container (LXC) doing the L2 cross\r
- connect loop. LXC running in privileged mode is pinned to dedicated\r
- cores. All VPP instances are same version.\r
-\r
- - **Stateful Security Groups**\r
-\r
- - **VM vhost use cases**\r
-\r
-Performance Improvements\r
-------------------------\r
-\r
-Substantial improvements in measured packet throughput have been\r
-observed in a number of CSIT |release| tests listed below, with relative\r
-increase of double-digit percentage points. Relative improvements are\r
-calculated against the test results listed in CSIT |release-1| report.\r
-VPP-16.09 numbers are provided for reference.\r
-\r
-NDR Throughput\r
-~~~~~~~~~~~~~~\r
-\r
-Non-Drop Rate Throughput discovery tests:\r
-\r
-.. csv-table::\r
- :align: center\r
- :header-rows: 1\r
- :file: ../../../docs/report/vpp_performance_tests/performance_improvements/ndr_throughput.csv\r
-\r
-PDR Throughput\r
-~~~~~~~~~~~~~~\r
-\r
-Partial Drop Rate thoughput discovery tests with packet Loss Tolerance of 0.5%:\r
-\r
-.. csv-table::\r
- :align: center\r
- :header-rows: 1\r
- :file: ../../../docs/report/vpp_performance_tests/performance_improvements/pdr_throughput.csv\r
-\r
-Measured improvements are in line with VPP code optimizations listed in\r
-`VPP-17.07 release notes\r
-<https://docs.fd.io/vpp/17.07/release_notes_1707.html>`_.\r
-\r
-Other Performance Changes\r
--------------------------\r
-\r
-Other changes in measured packet throughput, with either minor relative\r
-increase or decrease, have been observed in a number of CSIT |release|\r
-tests listed below. Relative changes are calculated against the test\r
-results listed in CSIT |release-1| report.\r
-\r
-NDR Throughput\r
-~~~~~~~~~~~~~~\r
-\r
-Non-Drop Rate Throughput discovery tests:\r
-\r
-.. csv-table::\r
- :align: center\r
- :header-rows: 1\r
- :file: ../../../docs/report/vpp_performance_tests/performance_improvements/ndr_throughput_others.csv\r
-\r
-PDR Throughput\r
-~~~~~~~~~~~~~~\r
-\r
-Partial Drop Rate thoughput discovery tests with packet Loss Tolerance of 0.5%:\r
-\r
-.. csv-table::\r
- :align: center\r
- :header-rows: 1\r
- :file: ../../../docs/report/vpp_performance_tests/performance_improvements/pdr_throughput_others.csv\r
-\r
-\r
-Known Issues\r
-------------\r
-\r
-Here is the list of known issues in CSIT |release| for VPP performance tests:\r
-\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| # | Issue | Jira ID | Description |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 1 | NDR discovery test failures 1518B frame size | VPP-663 | VPP reporting errors: dpdk-input Rx ip checksum errors. |\r
-| | for ip4scale200k, ip4scale2m scale IPv4 routed- | | Observed frequency: all test runs. |\r
-| | forwarding tests. ip4scale20k tests are fine. | | |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 2 | Vic1385 and Vic1227 low performance. | VPP-664 | Low NDR performance. |\r
-| | | | |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 3 | Sporadic NDR discovery test failures on x520. | CSIT-750 | Suspected issue with HW settings (BIOS, FW) in LF |\r
-| | | | infrastructure. Issue can't be replicated outside LF. |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 4 | VPP in 2t2c setups - large variation | CSIT-568 | Suspected NIC firmware or DPDK driver issue affecting NDR |\r
-| | of discovered NDR throughput values across | | throughput. Applies to XL710 and X710 NICs, x520 NICs are fine. |\r
-| | multiple test runs with xl710 and x710 NICs. | | |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 5 | Lower than expected NDR and PDR throughput with | CSIT-569 | Suspected NIC firmware or DPDK driver issue affecting NDR and |\r
-| | xl710 and x710 NICs, compared to x520 NICs. | | PDR throughput. Applies to XL710 and X710 NICs. |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-\r
+Release Notes
+=============
+
+Changes in |csit-release|
+-------------------------
+
+#. VPP PERFORMANCE TESTS
+
+ - **Service density 2n-skx tests**: Network Function Virtualization (NFV)
+ service density tests focus on measuring total per server throughput at
+ varied NFV service *packing* densities with vswitch providing host
+ dataplane. The goal is to compare and contrast performance of a shared
+ vswitch for different network topologies and virtualization technologies,
+ and their impact on vswitch performance and efficiency in a range of NFV
+ service configurations.
+
+ - **Experimental Soak Tests**: Added performamce soak tests framework
+ code for extended time duration tests and throughput discovery
+ at given PLR and at give total test time e.g. minutes, hours,
+ days, weeks, months, years. See updated
+ :ref:`test_methodology` section for more details.
+
+#. TEST FRAMEWORK
+
+ - **Container code optimizations**: Optimized container library allows to
+ run containre_memif tests faster.
+
+ - **CSIT PAPI Support**: Continue converting existing VAT L1 keywords to
+ PAPI L1 KWs in CSIT using VPP Python bindings. Required for migrating away
+ from VAT.
+
+ - **General Code Housekeeping**: Ongoing RF keywords optimizations,
+ removal of redundant RF keywords.
+
+#. PRESENTATION AND ANALYTICS LAYER
+
+ - **Graphs Layout Improvements**: Improved performance graphs layout
+ for better readibility and maintenance: test grouping, axis
+ labels, descriptions, other informative decoration.
+
+#. MISCELLANEOUS
+
+ - **2n-dnv Tests (3rd Party)**: Published performance tests for 2n-
+ dnv (2-Node Atom Denverton) from 3rd party testbeds running FD.io
+ |csit-release| automated testing code.
+ Only graphs for Packet Throughput and Speedup Multi-core and not
+ for Packet Latency were published as there are no results for Packet
+ Latency available.
+
+.. raw:: latex
+
+ \clearpage
+
+.. _vpp_known_issues:
+
+Known Issues
+------------
+
+List of known issues in |csit-release| for VPP performance tests:
+
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+
+| # | JiraID | Issue Description |
++====+=========================================+=================================================================================================================================+
+| 1 | `CSIT-570 | Sporadic (1 in 200) NDR discovery test failures on x520. DPDK reporting rx-errors, indicating L1 issue. |
+| | <https://jira.fd.io/browse/CSIT-570>`_ | Suspected issue with HW combination of X710-X520 in LF testbeds. Not observed outside of LF testbeds. |
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+
+| 2 | `VPP-1563 | AVF L2patch tests are failing for all packet size and core combination. Reason: null-node blackholed packets in show error. |
+| | <https://jira.fd.io/browse/VPP-1563>`_ | |
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+
+| 3 | `CSIT-1234 | VPP IPSecHW/IPSecsW scale interface mode, low NDR and PDR 64B throughput in 3n-hsw testbeds, in CSIT-19.01 vs. CSIT-18.10. |
+| | <https://jira.fd.io/browse/CSIT-1234>`_ | |
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+
+| 4 | `CSIT-1431 | AVF 4 cores tests are sporadically failing. Under investigation. |
+| | <https://jira.fd.io/browse/CSIT-1431>`_ | |
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+
+| 5 | `CSIT-1465 | 4c VPP VM vhost tests failing on 3n-skx. Under investigation. |
+| | <https://jira.fd.io/browse/CSIT-1465>`_ | |
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+
+| 6 | `CSIT-1466 | IPSecHW scale tests failing due to VPP reset. Fixed in one of subsequent VPP patches. Confirmed by running tests with VPP |
+| | <https://jira.fd.io/browse/CSIT-1466>`_ | build 19.01.1-8~g50a392f~b56. |
++----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+