Overview
========
+VPP performance test results are reported for all three physical testbed
+types present in FD.io labs: 3-Node Xeon Haswell (3n-hsw), 3-Node Xeon
+Skylake (3n-skx), 2-Node Xeon Skylake (2n-skx) and installed NIC models.
For description of physical testbeds used for VPP performance tests
please refer to :ref:`tested_physical_topologies`.
.. raw:: latex
\begin{figure}[H]
- \centering
- \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-2n-nic2nic}
- \label{fig:logical-2n-nic2nic}
+ \centering
+ \graphicspath{{../_tmp/src/vpp_performance_tests/}}
+ \includegraphics[width=0.90\textwidth]{logical-2n-nic2nic}
+ \label{fig:logical-2n-nic2nic}
\end{figure}
.. only:: html
.. raw:: latex
\begin{figure}[H]
- \centering
- \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-3n-nic2nic}
- \label{fig:logical-3n-nic2nic}
+ \centering
+ \graphicspath{{../_tmp/src/vpp_performance_tests/}}
+ \includegraphics[width=0.90\textwidth]{logical-3n-nic2nic}
+ \label{fig:logical-3n-nic2nic}
\end{figure}
.. only:: html
.. raw:: latex
\begin{figure}[H]
- \centering
- \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-2n-vm-vhost}
- \label{fig:logical-2n-vm-vhost}
+ \centering
+ \graphicspath{{../_tmp/src/vpp_performance_tests/}}
+ \includegraphics[width=0.90\textwidth]{logical-2n-vm-vhost}
+ \label{fig:logical-2n-vm-vhost}
\end{figure}
.. only:: html
.. raw:: latex
\begin{figure}[H]
- \centering
- \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-3n-vm-vhost}
- \label{fig:logical-3n-vm-vhost}
+ \centering
+ \graphicspath{{../_tmp/src/vpp_performance_tests/}}
+ \includegraphics[width=0.90\textwidth]{logical-3n-vm-vhost}
+ \label{fig:logical-3n-vm-vhost}
\end{figure}
.. only:: html
.. raw:: latex
\begin{figure}[H]
- \centering
- \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-2n-container-memif}
- \label{fig:logical-2n-container-memif}
+ \centering
+ \graphicspath{{../_tmp/src/vpp_performance_tests/}}
+ \includegraphics[width=0.90\textwidth]{logical-2n-container-memif}
+ \label{fig:logical-2n-container-memif}
\end{figure}
.. only:: html
.. raw:: latex
\begin{figure}[H]
- \centering
- \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-3n-container-memif}
- \label{fig:logical-3n-container-memif}
+ \centering
+ \graphicspath{{../_tmp/src/vpp_performance_tests/}}
+ \includegraphics[width=0.90\textwidth]{logical-3n-container-memif}
+ \label{fig:logical-3n-container-memif}
\end{figure}
.. only:: html
regardless of packet loss. Maximum load for specified Ethernet frame
size is set to the bi-directional link rate.
-|csit-release| includes following performance test areas covered across
-a range of NIC drivers and NIC models:
+|csit-release| includes following VPP data plane functionality
+performance tested across a range of NIC drivers and NIC models:
+-----------------------+----------------------------------------------+
-| Test Area | Description |
+| Functionality | Description |
+=======================+==============================================+
| ACL | L2 Bridge-Domain switching and |
| | IPv4and IPv6 routing with iACL and oACL IP |
| VPP TCP/IP stack | Tests of VPP TCP/IP stack used with VPP |
| | built-in HTTP server. |
+-----------------------+----------------------------------------------+
+| VTS | Virtual Topology System use case tests |
+| | combining VXLAN overlay tunneling with L2BD, |
+| | ACL and KVM VM vhost-user features. |
++-----------------------+----------------------------------------------+
| VXLAN | VXLAN overlay tunnelling integration with |
| | L2XC and L2BD. |
+-----------------------+----------------------------------------------+