return bd_config->feature_bitmap;
}
+void
+l2input_interface_mac_change (u32 sw_if_index,
+ const u8 * old_address, const u8 * new_address)
+{
+ /* check if the sw_if_index passed is a BVI in a BD */
+ l2_input_config_t *intf_config;
+
+ intf_config = l2input_intf_config (sw_if_index);
+
+ if (intf_config->bridge && intf_config->bvi)
+ {
+ /* delete and re-add l2fib entry for the bvi interface */
+ l2fib_del_entry (old_address, intf_config->bd_index, sw_if_index);
+ l2fib_add_entry (new_address,
+ intf_config->bd_index,
+ sw_if_index,
+ L2FIB_ENTRY_RESULT_FLAG_BVI |
+ L2FIB_ENTRY_RESULT_FLAG_STATIC);
+ }
+}
+
/**
* Set the subinterface to run in l2 or l3 mode.
* For L3 mode, just the sw_if_index is specified.
config->bvi = 1;
/* create the l2fib entry for the bvi interface */
- l2fib_add_fwd_entry (hi->hw_address, bd_index, sw_if_index, 1, 1); /* static + bvi */
+ l2fib_add_entry (hi->hw_address, bd_index, sw_if_index,
+ L2FIB_ENTRY_RESULT_FLAG_BVI |
+ L2FIB_ENTRY_RESULT_FLAG_STATIC);
/* Disable learning by default. no use since l2fib entry is static. */
config->feature_bitmap &= ~L2INPUT_FEAT_LEARN;
/*?
* Use this command put an interface into Layer 2 cross-connect mode.
- * Both interfaces must be in this mode for bi-directioal traffic. All
+ * Both interfaces must be in this mode for bi-directional traffic. All
* packets received on one interface will be transmitted to the other.
* To remove the Layer 2 cross-connect, put the interface in a different
* mode, for example Layer 3 mode.
}
/*?
- * Show the packet processing mode (Layer2 xcross-onnect, Layer 2 bridge,
+ * Show the packet processing mode (Layer2 cross-connect, Layer 2 bridge,
* Layer 3 routed) of all interfaces and sub-interfaces, or limit the
* output to just the provided list of interfaces and sub-interfaces.
* The output shows the mode, the interface, and if the interface is
- * a member of a bridge, the bridge-domain-id and the split horizen group (shg).
+ * a member of a bridge, the bridge-domain-id and the split horizon group (shg).
*
* @cliexpar
* Example of displaying the mode of all interfaces:
* l2 xconnect GigabitEthernet0/8/0.300 GigabitEthernet0/9/0.300
* l2 xconnect GigabitEthernet0/9/0.300 GigabitEthernet0/8/0.300
* @cliexend
- * Example of displaying the mode of a seleted list of interfaces:
+ * Example of displaying the mode of a selected list of interfaces:
* @cliexstart{show mode GigabitEthernet0/8/0 GigabitEthernet0/8/0.200}
* l3 GigabitEthernet0/8/0
* l2 bridge GigabitEthernet0/8/0.200 bd_id 200 shg 0