dpdk: correct build to include rdma driver
[vpp.git] / test / test_flowprobe.py
index 6b27179..1d565dc 100644 (file)
@@ -13,7 +13,8 @@ from scapy.layers.inet import IP, TCP, UDP
 from scapy.layers.inet6 import IPv6
 
 from config import config
-from framework import tag_fixme_vpp_workers
+from framework import tag_fixme_vpp_workers, tag_fixme_ubuntu2204, tag_fixme_debian11
+from framework import is_distro_ubuntu2204, is_distro_debian11
 from framework import VppTestCase, VppTestRunner
 from framework import tag_run_solo
 from vpp_object import VppObject
@@ -39,9 +40,11 @@ class VppCFLOW(VppObject):
         mtu=1024,
         datapath="l2",
         layer="l2 l3 l4",
+        direction="tx",
     ):
         self._test = test
         self._intf = intf
+        self._intf_obj = getattr(self._test, intf)
         self._active = active
         if passive == 0 or passive < active:
             self._passive = active + 1
@@ -49,6 +52,7 @@ class VppCFLOW(VppObject):
             self._passive = passive
         self._datapath = datapath  # l2 ip4 ip6
         self._collect = layer  # l2 l3 l4
+        self._direction = direction  # rx tx both
         self._timeout = timeout
         self._mtu = mtu
         self._configured = False
@@ -64,7 +68,7 @@ class VppCFLOW(VppObject):
             l3_flag = VppEnum.vl_api_flowprobe_record_flags_t.FLOWPROBE_RECORD_FLAG_L3
         if "l4" in self._collect.lower():
             l4_flag = VppEnum.vl_api_flowprobe_record_flags_t.FLOWPROBE_RECORD_FLAG_L4
-        self._test.vapi.flowprobe_params(
+        self._test.vapi.flowprobe_set_params(
             record_flags=(l2_flag | l3_flag | l4_flag),
             active_timer=self._active,
             passive_timer=self._passive,
@@ -87,18 +91,32 @@ class VppCFLOW(VppObject):
             template_interval=self._timeout,
         )
 
-    def enable_flowprobe_feature(self):
-        self._test.vapi.ppcli(
-            "flowprobe feature add-del %s %s" % (self._intf, self._datapath)
+    def _enable_disable_flowprobe_feature(self, is_add):
+        which_map = {
+            "l2": VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_L2,
+            "ip4": VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_IP4,
+            "ip6": VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_IP6,
+        }
+        direction_map = {
+            "rx": VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_RX,
+            "tx": VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_TX,
+            "both": VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_BOTH,
+        }
+        self._test.vapi.flowprobe_interface_add_del(
+            is_add=is_add,
+            which=which_map[self._datapath],
+            direction=direction_map[self._direction],
+            sw_if_index=self._intf_obj.sw_if_index,
         )
 
+    def enable_flowprobe_feature(self):
+        self._enable_disable_flowprobe_feature(is_add=True)
+
     def disable_exporter(self):
         self._test.vapi.cli("set ipfix exporter collector 0.0.0.0")
 
     def disable_flowprobe_feature(self):
-        self._test.vapi.cli(
-            "flowprobe feature add-del %s %s disable" % (self._intf, self._datapath)
-        )
+        self._enable_disable_flowprobe_feature(is_add=False)
 
     def object_id(self):
         return "ipfix-collector-%s-%s" % (self._src, self.dst)
@@ -134,6 +152,10 @@ class MethodHolder(VppTestCase):
         variables and configure VPP.
         """
         super(MethodHolder, cls).setUpClass()
+        if (is_distro_ubuntu2204 == True or is_distro_debian11 == True) and not hasattr(
+            cls, "vpp"
+        ):
+            return
         try:
             # Create pg interfaces
             cls.create_pg_interfaces(range(9))
@@ -143,7 +165,9 @@ class MethodHolder(VppTestCase):
 
             # Create BD with MAC learning and unknown unicast flooding disabled
             # and put interfaces to this BD
-            cls.vapi.bridge_domain_add_del(bd_id=1, uu_flood=1, learn=1)
+            cls.vapi.bridge_domain_add_del_v2(
+                bd_id=1, uu_flood=1, learn=1, flood=1, forward=1, is_add=1
+            )
             cls.vapi.sw_interface_set_l2_bridge(
                 rx_sw_if_index=cls.pg1._sw_if_index, bd_id=1
             )
@@ -261,8 +285,6 @@ class MethodHolder(VppTestCase):
                         continue
 
                     for field in data_set:
-                        if field not in record.keys():
-                            continue
                         value = data_set[field]
                         if value == "octets":
                             value = ip_layer.len
@@ -322,6 +344,8 @@ class MethodHolder(VppTestCase):
 
 @tag_run_solo
 @tag_fixme_vpp_workers
+@tag_fixme_ubuntu2204
+@tag_fixme_debian11
 class Flowprobe(MethodHolder):
     """Template verification, timer tests"""
 
@@ -434,6 +458,8 @@ class Flowprobe(MethodHolder):
             self.assertEqual(int(binascii.hexlify(record[10]), 16), 8)
             # egress interface
             self.assertEqual(int(binascii.hexlify(record[14]), 16), 9)
+            # direction
+            self.assertEqual(int(binascii.hexlify(record[61]), 16), 1)
             # packets
             self.assertEqual(int(binascii.hexlify(record[2]), 16), 1)
             # src mac
@@ -464,25 +490,117 @@ class Flowprobe(MethodHolder):
         ipfix.remove_vpp_config()
         self.logger.info("FFP_TEST_FINISH_0000")
 
+    def test_interface_dump(self):
+        """Dump interfaces with IPFIX flow record generation enabled"""
+        self.logger.info("FFP_TEST_START_0003")
 
-@tag_fixme_vpp_workers
-class Datapath(MethodHolder):
+        # Enable feature for 3 interfaces
+        ipfix1 = VppCFLOW(test=self, intf="pg1", datapath="l2", direction="rx")
+        ipfix1.add_vpp_config()
+
+        ipfix2 = VppCFLOW(test=self, intf="pg2", datapath="ip4", direction="tx")
+        ipfix2.enable_flowprobe_feature()
+
+        ipfix3 = VppCFLOW(test=self, intf="pg3", datapath="ip6", direction="both")
+        ipfix3.enable_flowprobe_feature()
+
+        # When request "all", dump should contain all enabled interfaces
+        dump = self.vapi.flowprobe_interface_dump()
+        self.assertEqual(len(dump), 3)
+
+        # Verify 1st interface
+        self.assertEqual(dump[0].sw_if_index, self.pg1.sw_if_index)
+        self.assertEqual(
+            dump[0].which, VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_L2
+        )
+        self.assertEqual(
+            dump[0].direction,
+            VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_RX,
+        )
+
+        # Verify 2nd interface
+        self.assertEqual(dump[1].sw_if_index, self.pg2.sw_if_index)
+        self.assertEqual(
+            dump[1].which, VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_IP4
+        )
+        self.assertEqual(
+            dump[1].direction,
+            VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_TX,
+        )
+
+        # Verify 3rd interface
+        self.assertEqual(dump[2].sw_if_index, self.pg3.sw_if_index)
+        self.assertEqual(
+            dump[2].which, VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_IP6
+        )
+        self.assertEqual(
+            dump[2].direction,
+            VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_BOTH,
+        )
+
+        # When request 2nd interface, dump should contain only the specified interface
+        dump = self.vapi.flowprobe_interface_dump(sw_if_index=self.pg2.sw_if_index)
+        self.assertEqual(len(dump), 1)
+
+        # Verify 2nd interface
+        self.assertEqual(dump[0].sw_if_index, self.pg2.sw_if_index)
+        self.assertEqual(
+            dump[0].which, VppEnum.vl_api_flowprobe_which_t.FLOWPROBE_WHICH_IP4
+        )
+        self.assertEqual(
+            dump[0].direction,
+            VppEnum.vl_api_flowprobe_direction_t.FLOWPROBE_DIRECTION_TX,
+        )
+
+        # When request 99th interface, dump should be empty
+        dump = self.vapi.flowprobe_interface_dump(sw_if_index=99)
+        self.assertEqual(len(dump), 0)
+
+        ipfix1.remove_vpp_config()
+        ipfix2.remove_vpp_config()
+        ipfix3.remove_vpp_config()
+        self.logger.info("FFP_TEST_FINISH_0003")
+
+    def test_get_params(self):
+        """Get IPFIX flow record generation parameters"""
+        self.logger.info("FFP_TEST_START_0004")
+
+        # Enable feature for an interface with custom parameters
+        ipfix = VppCFLOW(test=self, active=20, passive=40, layer="l2 l3 l4")
+        ipfix.add_vpp_config()
+
+        # Get and verify parameters
+        params = self.vapi.flowprobe_get_params()
+        self.assertEqual(params.active_timer, 20)
+        self.assertEqual(params.passive_timer, 40)
+        record_flags = VppEnum.vl_api_flowprobe_record_flags_t.FLOWPROBE_RECORD_FLAG_L2
+        record_flags |= VppEnum.vl_api_flowprobe_record_flags_t.FLOWPROBE_RECORD_FLAG_L3
+        record_flags |= VppEnum.vl_api_flowprobe_record_flags_t.FLOWPROBE_RECORD_FLAG_L4
+        self.assertEqual(params.record_flags, record_flags)
+
+        ipfix.remove_vpp_config()
+        self.logger.info("FFP_TEST_FINISH_0004")
+
+
+class DatapathTestsHolder(object):
     """collect information on Ethernet, IP4 and IP6 datapath (no timers)"""
 
     @classmethod
     def setUpClass(cls):
-        super(Datapath, cls).setUpClass()
+        super(DatapathTestsHolder, cls).setUpClass()
 
     @classmethod
     def tearDownClass(cls):
-        super(Datapath, cls).tearDownClass()
+        super(DatapathTestsHolder, cls).tearDownClass()
 
     def test_templatesL2(self):
         """verify template on L2 datapath"""
         self.logger.info("FFP_TEST_START_0000")
         self.pg_enable_capture(self.pg_interfaces)
 
-        ipfix = VppCFLOW(test=self, layer="l2")
+        ipfix = VppCFLOW(
+            test=self, intf=self.intf1, layer="l2", direction=self.direction
+        )
         ipfix.add_vpp_config()
 
         # template packet should arrive immediately
@@ -499,7 +617,9 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, layer="l2")
+        ipfix = VppCFLOW(
+            test=self, intf=self.intf1, layer="l2", direction=self.direction
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -513,7 +633,10 @@ class Datapath(MethodHolder):
         self.vapi.ipfix_flush()
         cflow = self.wait_for_cflow_packet(self.collector, templates[0])
         self.verify_cflow_data_detail(
-            ipfix_decoder, capture, cflow, {2: "packets", 256: 8}
+            ipfix_decoder,
+            capture,
+            cflow,
+            {2: "packets", 256: 8, 61: (self.direction == "tx")},
         )
         self.collector.get_capture(2)
 
@@ -526,7 +649,9 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, layer="l3")
+        ipfix = VppCFLOW(
+            test=self, intf=self.intf1, layer="l3", direction=self.direction
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -543,7 +668,13 @@ class Datapath(MethodHolder):
             ipfix_decoder,
             capture,
             cflow,
-            {2: "packets", 4: 17, 8: "src_ip", 12: "dst_ip"},
+            {
+                2: "packets",
+                4: 17,
+                8: "src_ip",
+                12: "dst_ip",
+                61: (self.direction == "tx"),
+            },
         )
 
         self.collector.get_capture(3)
@@ -557,7 +688,9 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, layer="l4")
+        ipfix = VppCFLOW(
+            test=self, intf=self.intf1, layer="l4", direction=self.direction
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -571,7 +704,10 @@ class Datapath(MethodHolder):
         self.vapi.ipfix_flush()
         cflow = self.wait_for_cflow_packet(self.collector, templates[0])
         self.verify_cflow_data_detail(
-            ipfix_decoder, capture, cflow, {2: "packets", 7: "sport", 11: "dport"}
+            ipfix_decoder,
+            capture,
+            cflow,
+            {2: "packets", 7: "sport", 11: "dport", 61: (self.direction == "tx")},
         )
 
         self.collector.get_capture(3)
@@ -585,7 +721,9 @@ class Datapath(MethodHolder):
 
         self.pg_enable_capture(self.pg_interfaces)
 
-        ipfix = VppCFLOW(test=self, datapath="ip4")
+        ipfix = VppCFLOW(
+            test=self, intf=self.intf1, datapath="ip4", direction=self.direction
+        )
         ipfix.add_vpp_config()
 
         # template packet should arrive immediately
@@ -603,7 +741,13 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, intf="pg4", layer="l2", datapath="ip4")
+        ipfix = VppCFLOW(
+            test=self,
+            intf=self.intf2,
+            layer="l2",
+            datapath="ip4",
+            direction=self.direction,
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -617,7 +761,10 @@ class Datapath(MethodHolder):
         self.vapi.ipfix_flush()
         cflow = self.wait_for_cflow_packet(self.collector, templates[0])
         self.verify_cflow_data_detail(
-            ipfix_decoder, capture, cflow, {2: "packets", 256: 8}
+            ipfix_decoder,
+            capture,
+            cflow,
+            {2: "packets", 256: 8, 61: (self.direction == "tx")},
         )
 
         # expected two templates and one cflow packet
@@ -632,7 +779,13 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, intf="pg4", layer="l3", datapath="ip4")
+        ipfix = VppCFLOW(
+            test=self,
+            intf=self.intf2,
+            layer="l3",
+            datapath="ip4",
+            direction=self.direction,
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -649,7 +802,13 @@ class Datapath(MethodHolder):
             ipfix_decoder,
             capture,
             cflow,
-            {1: "octets", 2: "packets", 8: "src_ip", 12: "dst_ip"},
+            {
+                1: "octets",
+                2: "packets",
+                8: "src_ip",
+                12: "dst_ip",
+                61: (self.direction == "tx"),
+            },
         )
 
         # expected two templates and one cflow packet
@@ -664,7 +823,13 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, intf="pg4", layer="l4", datapath="ip4")
+        ipfix = VppCFLOW(
+            test=self,
+            intf=self.intf2,
+            layer="l4",
+            datapath="ip4",
+            direction=self.direction,
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -678,7 +843,10 @@ class Datapath(MethodHolder):
         self.vapi.ipfix_flush()
         cflow = self.wait_for_cflow_packet(self.collector, templates[0])
         self.verify_cflow_data_detail(
-            ipfix_decoder, capture, cflow, {2: "packets", 7: "sport", 11: "dport"}
+            ipfix_decoder,
+            capture,
+            cflow,
+            {2: "packets", 7: "sport", 11: "dport", 61: (self.direction == "tx")},
         )
 
         # expected two templates and one cflow packet
@@ -692,7 +860,9 @@ class Datapath(MethodHolder):
         self.logger.info("FFP_TEST_START_0000")
         self.pg_enable_capture(self.pg_interfaces)
 
-        ipfix = VppCFLOW(test=self, datapath="ip6")
+        ipfix = VppCFLOW(
+            test=self, intf=self.intf1, datapath="ip6", direction=self.direction
+        )
         ipfix.add_vpp_config()
 
         # template packet should arrive immediately
@@ -709,7 +879,13 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, intf="pg6", layer="l2", datapath="ip6")
+        ipfix = VppCFLOW(
+            test=self,
+            intf=self.intf3,
+            layer="l2",
+            datapath="ip6",
+            direction=self.direction,
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -723,7 +899,11 @@ class Datapath(MethodHolder):
         self.vapi.ipfix_flush()
         cflow = self.wait_for_cflow_packet(self.collector, templates[0])
         self.verify_cflow_data_detail(
-            ipfix_decoder, capture, cflow, {2: "packets", 256: 56710}, ip_ver="v6"
+            ipfix_decoder,
+            capture,
+            cflow,
+            {2: "packets", 256: 56710, 61: (self.direction == "tx")},
+            ip_ver="v6",
         )
 
         # expected two templates and one cflow packet
@@ -738,7 +918,13 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, intf="pg6", layer="l3", datapath="ip6")
+        ipfix = VppCFLOW(
+            test=self,
+            intf=self.intf3,
+            layer="l3",
+            datapath="ip6",
+            direction=self.direction,
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -755,7 +941,7 @@ class Datapath(MethodHolder):
             ipfix_decoder,
             capture,
             cflow,
-            {2: "packets", 27: "src_ip", 28: "dst_ip"},
+            {2: "packets", 27: "src_ip", 28: "dst_ip", 61: (self.direction == "tx")},
             ip_ver="v6",
         )
 
@@ -771,7 +957,13 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, intf="pg6", layer="l4", datapath="ip6")
+        ipfix = VppCFLOW(
+            test=self,
+            intf=self.intf3,
+            layer="l4",
+            datapath="ip6",
+            direction=self.direction,
+        )
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -788,7 +980,7 @@ class Datapath(MethodHolder):
             ipfix_decoder,
             capture,
             cflow,
-            {2: "packets", 7: "sport", 11: "dport"},
+            {2: "packets", 7: "sport", 11: "dport", 61: (self.direction == "tx")},
             ip_ver="v6",
         )
 
@@ -804,7 +996,7 @@ class Datapath(MethodHolder):
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self)
+        ipfix = VppCFLOW(test=self, intf=self.intf1, direction=self.direction)
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -824,12 +1016,12 @@ class Datapath(MethodHolder):
         self.logger.info("FFP_TEST_FINISH_0001")
 
     def test_0002(self):
-        """no timers, two CFLOW packets (mtu=256), 3 Flows in each"""
+        """no timers, two CFLOW packets (mtu=260), 3 Flows in each"""
         self.logger.info("FFP_TEST_START_0002")
         self.pg_enable_capture(self.pg_interfaces)
         self.pkts = []
 
-        ipfix = VppCFLOW(test=self, mtu=256)
+        ipfix = VppCFLOW(test=self, intf=self.intf1, direction=self.direction, mtu=260)
         ipfix.add_vpp_config()
 
         ipfix_decoder = IPFIXDecoder()
@@ -852,6 +1044,26 @@ class Datapath(MethodHolder):
         self.logger.info("FFP_TEST_FINISH_0002")
 
 
+@tag_fixme_vpp_workers
+class DatapathTx(MethodHolder, DatapathTestsHolder):
+    """Collect info on Ethernet, IP4 and IP6 datapath (TX) (no timers)"""
+
+    intf1 = "pg2"
+    intf2 = "pg4"
+    intf3 = "pg6"
+    direction = "tx"
+
+
+@tag_fixme_vpp_workers
+class DatapathRx(MethodHolder, DatapathTestsHolder):
+    """Collect info on Ethernet, IP4 and IP6 datapath (RX) (no timers)"""
+
+    intf1 = "pg1"
+    intf2 = "pg3"
+    intf3 = "pg5"
+    direction = "rx"
+
+
 @unittest.skipUnless(config.extended, "part of extended tests")
 class DisableIPFIX(MethodHolder):