# limitations under the License.
*** Settings ***
-| Resource | resources/libraries/robot/performance/performance_setup.robot
+| Resource | resources/libraries/robot/shared/default.robot
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
-| ... | VHOST_1024
+| ... | VHOST_1024 | NF_TESTPMD
| ...
-| Suite Setup | Set up 3-node performance topology with DUT's NIC model
-| ... | L2 | ${nic_name}
-| Suite Teardown | Tear down suite
-| ...
-| Test Setup | Set up performance test
+| Suite Setup | Setup suite single link | performance
+| Suite Teardown | Tear down suite | performance
+| Test Setup | Setup test
| Test Teardown | Tear down test | performance | vhost
| ...
| Test Template | Local Template
| ...
-| Documentation | *RFC2544: Pkt throughput L2BD with vhost abd IEEE 802.1Q test
+| Documentation | *RFC2544: Pkt throughput L2BD with vhost and IEEE 802.1Q test
| ... | cases*
| ...
| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology\
| ... | 802.1Q tagging is applied on link between DUT1 and DUT2.
| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 bridge-\
| ... | domain and MAC learning enabled. Qemu VNFs are \
-| ... | connected to VPP via vhost-user interfaces. Guest is running VPP l2xc \
+| ... | connected to VPP via vhost-user interfaces. Guest is running testpmd \
| ... | interconnecting vhost-user interfaces, rxd/txd=1024. DUT1/DUT2 is \
| ... | tested with ${nic_name}.
| ... | *[Ver] TG verification:* TG finds and reports throughput NDR (Non Drop\
| ... | *[Ref] Applicable standard specifications:* RFC2544.
*** Variables ***
+| @{plugins_to_enable}= | dpdk_plugin.so
+| ${osi_layer}= | L2
| ${nic_name}= | Intel-X710
| ${overhead}= | ${4}
| ${subid}= | 10
| | ...
| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
| | And Add PCI devices to all DUTs
-| | Set Max Rate And Jumbo And Handle Multi Seg
+| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
| | When Initialize L2 bridge domains with Vhost-User and VLAN in circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
| | ... | nf_chains=${nf_chains} | nf_nodes=${nf_nodes} | jumbo=${jumbo}
-| | ... | use_tuned_cfs=${False} | auto_scale=${True} | vnf=vpp_chain_l2xc
+| | ... | use_tuned_cfs=${False} | auto_scale=${True} | vnf=testpmd_io
| | Then Find NDR and PDR intervals using optimized search
*** Test Cases ***