pci_address: "0000:18:00.0"
ip4_address: "172.16.10.2"
driver: i40e
- link: link1
+ link: disabled1
model: Intel-X710
port2:
# s34-t27-tg1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE.
pci_address: "0000:18:00.1"
ip4_address: "172.16.20.2"
driver: i40e
- link: link2
+ link: disabled2
model: Intel-X710
port3:
# s34-t27-tg1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE.
# s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
mac_address: "ec:0d:9a:8c:c6:a7"
pci_address: "0000:5e:00.1"
- ip4_address: "172.16.70.1"
+ ip4_address: "172.16.80.2"
driver: mlx5_core
link: link8
model: Mellanox-CX556A
+ port9:
+ # s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ mac_address: "10:70:fd:15:60:54"
+ pci_address: "0000:86:00.0"
+ ip4_address: "172.16.90.2"
+ driver: mlx5_core
+ link: link9
+ model: Mellanox-CX556A
+ port10:
+ # s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ mac_address: "10:70:fd:15:60:55"
+ pci_address: "0000:86:00.1"
+ ip4_address: "172.16.100.2"
+ driver: mlx5_core
+ link: link10
+ model: Mellanox-CX556A
+ port11:
+ # s34-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ mac_address: "0c:42:a1:0b:92:1a"
+ pci_address: "0000:af:00.0"
+ ip4_address: "172.16.110.2"
+ driver: mlx5_core
+ link: link11
+ model: Mellanox-CX556A
+ port12:
+ # s34-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
+ mac_address: "0c:42:a1:0b:92:1b"
+ pci_address: "0000:af:00.1"
+ ip4_address: "172.16.120.2"
+ driver: mlx5_core
+ link: link11
+ model: Mellanox-CX556A
DUT1:
type: DUT
host: "10.32.8.18"
username: testuser
password: Csit1234
uio_driver: vfio-pci
- honeycomb:
- user: admin
- passwd: admin
- port: 8183
- netconf_port: 2831
interfaces:
port1:
# s33-t27-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE.
pci_address: "0000:18:00.0"
ip4_address: "172.16.10.1"
driver: i40e
- link: link1
+ link: disabled3
model: Intel-X710
port2:
# s33-t27-sut1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE.
pci_address: "0000:18:00.1"
ip4_address: "172.16.20.1"
driver: i40e
- link: link2
+ link: disabled4
model: Intel-X710
port3:
# s33-t27-sut1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE.
# s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
mac_address: "ec:0d:9a:8c:c6:96"
pci_address: "0000:5e:00.0"
- ip4_address: "172.16.70.2"
+ ip4_address: "172.16.70.1"
driver: mlx5_core
link: link7
model: Mellanox-CX556A
# s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
mac_address: "ec:0d:9a:8c:c6:96"
pci_address: "0000:5e:00.1"
- ip4_address: "172.16.70.1"
+ ip4_address: "172.16.80.1"
driver: mlx5_core
link: link8
model: Mellanox-CX556A
+ port9:
+ # s33-t27-sut1-c6/p1 - 100GE-port1 Intel E810-CQDA2 2p100GE.
+ mac_address: "b4:96:91:a2:fb:d0"
+ pci_address: "0000:86:00.0"
+ ip4_address: "172.16.90.1"
+ driver: ice
+ link: link9
+ model: Intel-E810CQ
+ port10:
+ # s33-t27-sut1-c6/p2 - 100GE-port1 Intel E810-CQDA2 2p100GE.
+ mac_address: "b4:96:91:a2:fb:d1"
+ pci_address: "0000:86:00.1"
+ ip4_address: "172.16.100.1"
+ driver: ice
+ link: link10
+ model: Intel-E810CQ
\ No newline at end of file