X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Fcontent%2Finfrastructure%2Ffdio_dc_testbed_specifications.md;h=da711240782e290b4deb1213a4c87314a0a403ba;hb=144e2057d8e27a9debb18ed8c0a59065fb27bace;hp=bbc487fcd62014b6bf6397d6051411c3904eace7;hpb=265352781a137add1dc01238f9594cdbde7d77ad;p=csit.git diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index bbc487fcd6..da71124078 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -19,7 +19,6 @@ Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs. #### LOM (IPMI) VLAN - - Subnet: 10.30.50.0/24 - Gateway: 10.30.50.1 - Broadcast: 10.30.50.255 @@ -40,41 +39,42 @@ To access these hosts, VPN connection is required. ### Summary List ``` - #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr - 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 - 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0 - 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 - 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 - 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 - 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 - 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 -10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 -11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 -12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 -13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 -13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 - Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 + #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd + 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0 + 3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0 + 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 + 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 0 + 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 0 + 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0 + 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0 + 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 0 +10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 +11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 +12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 +13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0 +14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 +15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0 +16. 3-Node-IcelakeD perf icxd icx 4 6 1 0 0 0 0 0 0 0 0 1 0 0 4 + Totals: 39 48 19.5 7 1 2 1 2 6 10 2 16.5 2 12 4 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) -Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC +Each 1-Node-Skylake testbed includes one SUT (Server-Type-B2) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. -### 1-Node-ThunderX2 Arm Marvell (1n-tx2) +### 1-Node-Altra Arm Ampere (1n-alt) -Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC +Each 1-Node-Altra testbed includes one SUT (Server-Type-E25) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. -### 1-Node-Cascadelake Xeon Intel (1n-clx) - -Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with -NIC ports connected back-to-back ([Server Types](#server-types)). +### 1-Node-Skylake Xeon Intel (1n-spr) +Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC +ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) @@ -140,6 +140,13 @@ TG (Server-Type-F3) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. +### 3-Node-IcelakeD Xeon Intel (3n-icxd) + +Each 3-Node-IcelakeD testbed includes two SUTs (Server-Type-I1) and one numa of +TG (Server-Type-F5) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-SnowRidge Atom Intel (3n-snr) Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one @@ -155,7 +162,7 @@ one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology Used for FD.io performance tests. -## Tesdtbed Naming Convention +## Testbed Naming Convention Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: @@ -178,7 +185,7 @@ connectivity and wiring across defined CSIT testbeds: FD.io CSIT lab contains following server types: -1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing. +1. **Server-Type-B1**: Purpose - Skylake Xeon hosts for FD.io builds and data processing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -198,7 +205,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. +2. **Server-Type-B2**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -215,8 +222,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. + - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. 3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. @@ -259,28 +266,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing. +5. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - IPMI and host management ports. @@ -301,7 +288,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing. +6. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -322,8 +309,8 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot10 d8:00.xx: empty. -8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - - Quantity: 3. +7. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. + - Quantity: 4. - Physical connectivity: - IPMI and host management ports. - no NIC ports, standalone setup. @@ -334,12 +321,16 @@ FD.io CSIT lab contains following server types: - RAM Memory: 12* 16GB DDR4-2933. - Disks: 4* 1.92TB SATA SSD. - NICs configuration: - - Numa0: - - no cards. - - Numa1: - - no cards. + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: empty. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. -9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing. +8. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -352,10 +343,10 @@ FD.io CSIT lab contains following server types: - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot2 41:00.xx: xxv710-da2-2p25GE Intel. - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing. +9. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -369,28 +360,9 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot3 81:00.xx: xxv710-da2 2p25GE Intel. -11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: GIGABYTE Rack Mount - - Motherboard: MT91-FS4-00 - - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - - RAM Memory: 16 * 16GB DIMM - - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - NICs configuration: - - Numa0: - - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. - - Numa1: - - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. - -12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. +10. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI(?) and host management ports. @@ -404,7 +376,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. +11. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -421,7 +393,7 @@ FD.io CSIT lab contains following server types: - Numa1: - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. -14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing. +12. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -440,7 +412,7 @@ FD.io CSIT lab contains following server types: - Numa1: - no cards. -15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build. +13. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -452,7 +424,28 @@ FD.io CSIT lab contains following server types: - RAM Memory: 12* 16GB DDR4-3200MT/s - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 -16. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing. +14. **Server-Type-E25**: Purpose - Altra Arm Ampere SUT for FD.io VPP_Device functional tests. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: Gigabyte E252-P30-00 2U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) M128-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41 (Arm), Variant 0x3, Architecture 0xf, Part 0xd0c (neoverse-n1), Revision 0x1 + - RAM Memory: 32* 32GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM9A3 + - NICs configuration: + - Numa0: + - PCIe Slot0 0000:01:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot1 0001:01:00.xx: ConnectX6-2p100GE Mellanox. + - PCIe Slot2 0002:03:00.xx: ConnectX5-2p10/25GE Mellanox. + - Numa1: + - PCIe Slot3 0003:02:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot5 0005:02:00.xx: ConnectX5-2p10/25GE Mellanox. + +15. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -470,10 +463,10 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot8 af:00.xx: xl710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -17. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. +16. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -490,11 +483,11 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel. - PCIe Slot9 ff:00.xx: empty. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot6 ca:00.xx: empty. - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 ff:00.xx: empty. -18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. +17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. - Quantity: 4. - Physical connectivity: - IPMI and host management ports. @@ -515,7 +508,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox. - PCIe Slot10 d8:00.xx: empty. -19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. +18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 4. - Physical connectivity: - IPMI and host management ports. @@ -536,7 +529,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox. - PCIe Slot10 d8:00.xx: empty. -20. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing. +19. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing. - Quantity: 6. - Physical connectivity: - IPMI and host management ports. @@ -557,7 +550,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -21. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing. +20. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -578,7 +571,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -22. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. +21. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -599,7 +592,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 ff:00.xx: empty. -23. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. +22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -614,7 +607,7 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, PCIe3.0 lane) - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -24. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. +23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -627,15 +620,15 @@ FD.io CSIT lab contains following server types: - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia. -25. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. +24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -648,15 +641,15 @@ FD.io CSIT lab contains following server types: - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: empty. -26. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -677,7 +670,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot11 d8:00.xx: empty. -27. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -698,7 +691,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -28. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -711,15 +704,15 @@ FD.io CSIT lab contains following server types: - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot2 3d:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot4 2c:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 17:00.xx: e810-XXVDA4-4p25GE Intel. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot7 86:00.xx: empty. - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -29. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -740,12 +733,48 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot11 d8:00.xx: empty. +29. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-741GE-TNRT. + - Motherboard: Super X13DEG-QT-P. + - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. + - RAM Memory: 16* 32GB DDR5-4800. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot7 86:00.xx: empty. + - PCIe Slot9 af:00.xx: empty. + - PCIe Slot11 d8:00.xx: empty. + +30. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing. + - Quantity: 4 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topology. + - Main HW configuration: + - Chassis: SuperMicro SYS-110D-20C-FRDN8TP. + - Motherboard: Super X12SDV-20C-SPT8F. + - Processors: 1* Intel Xeon D-2796NT. + - RAM Memory: 4* 32GB DDR4-3200 MEM-DR432MD-ER32. + - Disks: 1* 960GB SATA SSD HDS-25T0. + - NICs configuration: + - Numa0: (x16, PCIe4.0 lane) + - PCIe BuiltIn ??:00.xx: e810-XXVDA2-2p25GE Intel. + ## Testbeds Configuration ### 1-Node-Skylake (1n-skx) ``` -- SUT [Server-Type-B6]: +- SUT [Server-Type-B2]: - testbedname: testbed11. - hostname: s1-t11-sut1. - IPMI IP: 10.30.50.47 @@ -759,7 +788,11 @@ FD.io CSIT lab contains following server types: - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -- SUT [Server-Type-B6]: + - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE. + - s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE. +- SUT [Server-Type-B2]: - testbedname: testbed12. - hostname: s2-t12-sut1. - IPMI IP: 10.30.50.48 @@ -773,58 +806,72 @@ FD.io CSIT lab contains following server types: - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. + - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE. + - s2-t12-sut1-c8/p2 - 100GE-port2 e810-2p100GE. ``` -### 1-Node-ThunderX2 (1n-tx2) +### 1-Node-Altra (1n-alt) ``` -- SUT [Server-Type-E11]: +- SUT [Server-Type-E25]: - testbedname: testbed13 - - hostname: s55-t13-sut1 + - hostname: s70-t13-sut1 - IPMI IP: 10.30.50.70 - Host IP: 10.30.51.70 - portnames: - - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -- SUT [Server-Type-E11]: + - s70-t13-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s70-t13-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s70-t13-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s70-t13-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox. + - s70-t13-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. + - s70-t13-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. + - s70-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s70-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s70-t13-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. + - s70-t13-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. +- SUT [Server-Type-E25]: - testbedname: testbed14 - - hostname: s56-t14-sut1 + - hostname: s71-t14-sut1 - IPMI IP: 10.30.50.71 - Host IP: 10.30.51.71 - portnames: - - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s71-t14-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s71-t14-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s71-t14-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s71-t14-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox. + - s71-t14-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. + - s71-t14-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. + - s71-t14-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s71-t14-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s71-t14-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox. + - s71-t14-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox. ``` -### 1-Node-Cascadelake (1n-clx) +### 1-Node-SapphireRapids (1n-spr) ``` -- SUT [Server-Type-C1]: - - testbedname: testbed11. - - hostname: s32-t14-sut1. - - IPMI IP: 10.30.55.17 - - Host IP: 10.32.8.17 +- SUT [Server-Type-H7]: + - testbedname: testbed15. + - hostname: s30-t15-sut1. + - IPMI IP: 10.30.50.30 + - Host IP: 10.30.51.31 - portnames: - - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. + - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE. +- SUT [Server-Type-H7]: + - testbedname: testbed16. + - hostname: s31-t16-sut1. + - IPMI IP: 10.30.50.31 + - Host IP: 10.30.51.31 + - portnames: + - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE. ``` ### 2-Node-IxiaPS1L47 (2n-ps1) @@ -1005,8 +1052,8 @@ FD.io CSIT lab contains following server types: - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s27-t211-sut1-c18/p2 - 40GE-port2 xl710-QDA2-2p40GE. - TG [Server-Type-E31]: - testbedname: testbed33 and testbed211. - hostname: s19-t33t211-tg1. @@ -1170,40 +1217,6 @@ FD.io CSIT lab contains following server types: - s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. ``` -### 3-Node-Rangeley (3n-rng) - -Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - -``` -- ServerB22 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 - - Host IP: 10.30.51.9 - - portnames: - - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -- ServerB23 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 - - Host IP: 10.30.51.10 - - portnames: - - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -- ServerB24 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 - - Host IP: 10.30.51.11 - - portnames: - - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -``` - ### 3-Node-Taishan (3n-tsh) {{< figure src="/cdocs/testbed-3n-tsh.svg" >}} @@ -1262,8 +1275,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - portnames: - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. - - s62-t34-sut1-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE. + - s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s63-t34-sut2. @@ -1272,8 +1285,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - portnames: - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. - - s63-t34-sut2-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE. + - s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-E32]: - testbedname: testbed34. - hostname: s64-t34-tg1. @@ -1284,10 +1297,6 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` @@ -1311,8 +1320,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s65-t37-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT2 [Server-Type-F3]: - testbedname: testbed37. - hostname: s66-t37-sut2. @@ -1327,8 +1336,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s65-t37-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-F3]: - testbedname: testbed37. - hostname: s67-t37-tg1. @@ -1343,8 +1352,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s67-t37-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s67-t37-tg1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s67-t37-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s67-t37-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT1 [Server-Type-F3]: - testbedname: testbed38. - hostname: s78-t38-sut1. @@ -1359,8 +1368,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s78-t38-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s78-t38-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s78-t38-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s78-t38-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT2 [Server-Type-F3]: - testbedname: testbed38. - hostname: s79-t38-sut2. @@ -1375,8 +1384,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s79-t38-sut2-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s79-t38-sut2-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s79-t38-sut2-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s79-t38-sut2-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-F3]: - testbedname: testbed38. - hostname: s80-t38-tg1. @@ -1391,8 +1400,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s80-t38-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s80-t38-tg1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. + - s80-t38-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s80-t38-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. ``` ### 3-Node-SnowRidge (3n-snr) @@ -1565,6 +1574,65 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` +### 3-Node-IcelakeD (3n-icxd) + +{{< figure src="/cdocs/testbed-3n-icxd.svg" >}} + +``` +- ServerI1 [Server-Type-I1]: + - testbedname: testbed31. + - hostname: s32-t31-sut1. + - IPMI IP: 10.30.50.32 + - Host IP: 10.30.51.32 + - portnames: + - s32-t31-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE. + - s32-t31-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE. +- ServerI1 [Server-Type-I1]: + - testbedname: testbed31. + - hostname: s33-t31-sut2. + - IPMI IP: 10.30.50.33 + - Host IP: 10.30.51.33 + - portnames: + - s33-t31-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE. + - s33-t31-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE. +- ServerF3 [Server-Type-F5]: + - testbedname: testbed31. + - hostname: s90-t31t32-tg1. + - IPMI IP: 10.30.50.90 + - Host IP: 10.30.51.90 + - portnames: + - s90-t31t32-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s90-t31t32-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s90-t31t32-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s90-t31t32-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- ServerI1 [Server-Type-I1]: + - testbedname: testbed32. + - hostname: s34-t32-sut1. + - IPMI IP: 10.30.50.34 + - Host IP: 10.30.51.34 + - portnames: + - s34-t32-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE. + - s34-t32-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE. +- ServerI1 [Server-Type-I1]: + - testbedname: testbed32. + - hostname: s35-t32-sut2. + - IPMI IP: 10.30.50.35 + - Host IP: 10.30.51.35 + - portnames: + - s35-t32-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE. + - s35-t32-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE. +- ServerF3 [Server-Type-F5]: + - testbedname: testbed32. + - hostname: s90-t31t32-tg1. + - IPMI IP: 10.30.50.90 + - Host IP: 10.30.51.90 + - portnames: + - s90-t31t32-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s90-t31t32-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s90-t31t32-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s90-t31t32-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +``` + ## Testbed Wiring ### 1-Node-Skylake (1n-skx) @@ -1598,28 +1666,47 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. ``` -### 1-Node-ThunderX2 (1n-tx2) +### 1-Node-Altra (1n-alt) ``` - testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. + - s70-t13-sut1-c0/p1 - s70-t13-sut1-c3/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. + - s70-t13-sut1-c0/p2 - s70-t13-sut1-c3/p2. + - ring3 100GE-ports ConnectX6-2p100GE on SUTs: + - s70-t13-sut1-c1/p1 - s70-t13-sut1-c1/p2. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. + - s70-t13-sut1-c2/p1 - s70-t13-sut1-c5/p1. + - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s70-t13-sut1-c2/p2 - s70-t13-sut1-c5/p2. - testbed14: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. + - s71-t14-sut1-c0/p1 - s71-t14-sut1-c3/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. + - s71-t14-sut1-c0/p2 - s71-t14-sut1-c3/p2. + - ring3 100GE-ports ConnectX6-2p100GE on SUTs: + - s71-t14-sut1-c1/p1 - s71-t14-sut1-c1/p2. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. + - s71-t14-sut1-c2/p1 - s71-t14-sut1-c5/p1. + - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s71-t14-sut1-c2/p2 - s71-t14-sut1-c5/p2. +``` + +### 1-Node-SapphireRapids (1n-spr) + +``` +- testbed15: + - ring1 100GE-ports e810-2p100GE: + - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1. + - ring2 100GE-ports e810-2p100GE: + - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2. +- testbed16: + - ring1 100GE-ports e810-2p100GE: + - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1. + - ring2 100GE-ports e810-2p100GE: + - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2. ``` ### 2-Node-IxiaPS1L47 (2n-ps1) @@ -1740,7 +1827,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1. - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2. - testbed213: @@ -1758,7 +1845,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1. - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2. - testbed214: @@ -1776,7 +1863,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1. - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2. - testbed215: @@ -1794,7 +1881,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports e810-2CQDA2-2p100GE: - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. - - ring5 100GE-ports ConnectX7-2p100GE: + - ring5 200GE-ports ConnectX7-2p200GE: - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1. - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2. ``` @@ -1828,9 +1915,9 @@ To be completed. - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs: - - s64-t34-tg1-c8/p1 - s62-t34-sut1-c8/p2. + - s64-t34-tg1-c8/p1 - s62-t34-sut2-c8/p1. - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2. - - s63-t34-sut2-c8/p1 - s64-t34-tg1-c8/p2. + - s63-t34-sut1-c8/p2 - s64-t34-tg1-c8/p2. ``` ### 3-Node-Icelake (3n-icx) @@ -1852,10 +1939,10 @@ To be completed. - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. - - ring4 100GE-ports ConnectX6-2p100GE: - - s67-t37-tg1-c6/p1 - s65-t37-sut1-c6/p2. - - s65-t37-sut1-c6/p1 - s66-t37-sut2-c6/p2. - - s66-t37-sut2-c6/p1 - s67-t37-tg1-c9-c6/p2. + - ring4 200GE-ports ConnectX6-2p200GE: + - s67-t37-tg1-c10/p1 - s65-t37-sut1-c10/p2. + - s65-t37-sut1-c10/p1 - s66-t37-sut2-c10/p2. + - s66-t37-sut2-c10/p1 - s67-t37-tg1-c10/p2. - testbed38: - ring1 25GE-ports xxv710-DA2-2p25GE: - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. @@ -1872,10 +1959,10 @@ To be completed. - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. - - ring4 100GE-ports ConnectX6-2p100GE: - - s80-t38-tg1-c6/p1 to s78-t38-sut1-c6/p1. - - s78-t38-sut1-c6/p2 to s79-t38-sut2-c6/p2. - - s79-t38-sut2-c6/p1 to s80-t38-tg1-c6/p2. + - ring4 200GE-ports ConnectX6-2p200GE: + - s80-t38-tg1-c10/p1 to s78-t38-sut1-c10/p1. + - s78-t38-sut1-c10/p2 to s79-t38-sut2-c10/p2. + - s79-t38-sut2-c10/p1 to s80-t38-tg1-c10/p2. ``` ### 3-Node-SnowRidge (3n-snr) @@ -1923,7 +2010,7 @@ To be completed. - ring2 100GE-ports e810-2CQDA2-2p100GE: - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1. - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2. - - ring3 25GE-ports e810-XXVDA4-2p25GE: + - ring3 25GE-ports e810-XXVDA4-4p25GE: - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1. - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2. - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3. @@ -1939,7 +2026,7 @@ To be completed. - ring2 100GE-ports e810-2CQDA2-2p100GE: - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1. - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2. - - ring3 25GE-ports e810-XXVDA4-2p25GE: + - ring3 25GE-ports e810-XXVDA4-4p25GE: - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1. - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2. - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3. @@ -1948,4 +2035,19 @@ To be completed. - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2. - ring5 100GE-ports e810-2CQDA2-2p100GE: - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2. +``` + +### 3-Node-IcelakeD (3n-icxd) + +``` +- testbed31: + - ring1 25GE-ports e822cq-2p25GE: + - s90-t31t32-tg1-c4/p1 to s32-t31-sut1-c1/p1. + - s32-t31-sut1-c1/p2 to s33-t31-sut2-c1/p2. + - s33-t31-sut2-c1/p1 to s90-t31t32-tg1-c4/p2. +- testbed32: + - ring1 25GE-ports e822cq-2p25GE: + - s90-t31t32-tg1-c6/p1 to s34-t32-sut1-c1/p1. + - s34-t32-sut1-c1/p2 to s35-t32-sut2-c1/p2. + - s35-t32-sut2-c1/p1 to s90-t31t32-tg1-c6/p2. ``` \ No newline at end of file