X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=22dade917f556301f62fb1674a333d4f23be0d2d;hb=refs%2Fchanges%2F71%2F36971%2F2;hp=196c956deaefdd8064837b5a6e514596caab2289;hpb=7f1c5531d5f2b04b43ba84964a82f72e74469a59;p=csit.git diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 196c956dea..22dade917f 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -6,14 +6,12 @@ 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx) - 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx) - 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt) @@ -32,14 +30,12 @@ 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod) 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) - 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod) 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod) 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) - 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod) @@ -49,14 +45,12 @@ 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod) - 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod) 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod) 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) - 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo) 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod) @@ -95,12 +89,12 @@ hosted by LFN FD.io CSIT project. 12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0 13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0 14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0 -15. 3-Node-Altra perf alt icx 1 2 .5 0 0 0 0 0 0 0 2 0 0 .5 0 +15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0 16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0 17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0 18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0 19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2 - Totals: 34 44 21 4 17 1 2 3 3 2 4 7 2 15 2 + Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -122,13 +116,6 @@ NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. -### 2-Node-Skylake Xeon Intel (2n-skx) - -Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG -(Server-Type-B2) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - ### 2-Node-Denverton Atom Intel (2n-dnv) Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one @@ -178,12 +165,6 @@ TG (Server-Type-A2) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. -### 3-Node-Skylake Xeon Intel (3n-skx) - -Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one -TG (Server-Type-B2) connected in a 3-node circular topology. -Used for FD.io performance tests. - ### 3-Node-Rangeley Atom Testbeds Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one @@ -278,21 +259,20 @@ Name | Comment 10.30.50.13 | LF Reserved 10.30.50.14 | LF Reserved 10.30.50.15 | LF Reserved -10.30.50.22 | s42-nomad -10.30.50.24 | s43-nomad -10.30.50.25 | s44-nomad -10.30.50.26 | s45-nomad -10.30.50.28 | s41-nomad -10.30.50.29 | s39-nomad -10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0 -10.30.50.30 | s40-nomad -10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1 -10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2 +10.30.50.16 | s16-nomad +10.30.50.17 | s17-nomad +10.30.50.18 | s18-nomad +10.30.50.19 | s19-nomad +10.30.50.20 | s20-nomad +10.30.50.21 | s21-nomad +10.30.50.22 | s22-nomad +10.30.50.23 | s23-nomad +10.30.50.24 | s24-nomad +10.30.50.25 | s25-nomad +10.30.50.26 | s26-nomad 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 10.30.50.38 | fdio-marvell-dev -10.30.50.39 | s53-nomad -10.30.50.40 | s54-nomad 10.30.50.41 | s3-t21-sut1 10.30.50.42 | s4-t21-tg1 10.30.50.43 | s11-t31-sut1 @@ -312,16 +292,12 @@ Name | Comment 10.30.50.57 | s16-t32-tg1 10.30.50.58 | s25-t25-sut1 10.30.50.59 | s26-t25-tg1 -10.30.50.65 | s52-nomad -10.30.50.66 | s51-nomad -10.30.50.67 | s49-nomad -10.30.50.68 | s50-nomad 10.30.50.69 | s27-t211-sut1 10.30.50.70 | s55-t13-sut1 10.30.50.71 | s56-t14-sut1 10.30.50.72 | s62-t34-sut1 10.30.50.73 | s63-t34-sut2 -10.30.50.74 | s64-t34t36-tg1 +10.30.50.74 | s64-t34-tg1 10.30.50.75 | s65-t37-sut1 10.30.50.76 | s66-t37-sut2 10.30.50.77 | s67-t37-tg1 @@ -338,8 +314,8 @@ Name | Comment 10.30.50.88 | s88-t215-tg1 10.30.50.89 | s89-t39t310-tg1 10.30.50.90 | s90-t311t312-tg1 -10.30.50.91 | s58-nomad -10.30.50.92 | s59-nomad +10.30.50.91 | s91-nomad +10.30.50.92 | s92-nomad 10.30.50.93 | s93-t39-sut1 10.30.50.94 | s94-t39-sut2 10.30.50.255 | Broadcast @@ -349,10 +325,6 @@ Name | Comment 10.30.55.11 | s29-t26-sut1 10.30.55.12 | s30-t35-sut1 10.30.55.13 | s31-t35-sut2 -10.30.55.14 | s46-nomad -10.30.55.15 | s47-nomad -10.30.55.16 | s48-nomad -10.30.55.17 | s57-nomad 10.30.55.18 | s33-t27-sut1 10.30.55.19 | s34-t27-tg1 10.30.55.20 | s35-t28-sut1 @@ -377,18 +349,20 @@ Name | Comment 10.30.51.7 | LF Reserved 10.30.51.8 | LF Reserved 10.30.51.15 | LF Reserved -10.30.51.22 | s42-nomad -10.30.51.24 | s43-nomad -10.30.51.25 | s44-nomad -10.30.51.26 | s45-nomad -10.30.51.28 | s41-nomad -10.30.51.29 | s39-nomad -10.30.51.30 | s40-nomad +10.30.51.16 | s16-nomad +10.30.51.17 | s17-nomad +10.30.51.18 | s18-nomad +10.30.51.19 | s19-nomad +10.30.51.20 | s20-nomad +10.30.51.21 | s21-nomad +10.30.51.22 | s22-nomad +10.30.51.23 | s23-nomad +10.30.51.24 | s24-nomad +10.30.51.25 | s25-nomad +10.30.51.26 | s26-nomad 10.30.51.36 | s17-t33-sut1 10.30.51.37 | s18-t33-sut2 10.30.51.38 | fdio-marvell-dev -10.30.51.39 | s53-nomad -10.30.51.40 | s54-nomad 10.30.51.44 | s3-t21-sut1 10.30.51.45 | s4-t21-tg1 10.30.51.46 | s11-t31-sut1 @@ -408,16 +382,12 @@ Name | Comment 10.30.51.60 | s16-t32-tg1 10.30.51.61 | s25-t25-sut1 10.30.51.62 | s26-t25-tg1 -10.30.51.65 | s52-nomad -10.30.51.66 | s51-nomad -10.30.51.67 | s49-nomad -10.30.51.68 | s50-nomad 10.30.51.69 | s27-t211-sut1 10.30.51.70 | s55-t13-sut1 10.30.51.71 | s56-t14-sut1 10.30.51.72 | s62-t34-sut1 10.30.51.73 | s63-t34-sut2 -10.30.51.74 | s64-t34t36-tg1 +10.30.51.74 | s64-t34-tg1 10.30.51.75 | s65-t37-sut1 10.30.51.76 | s66-t37-sut2 10.30.51.77 | s67-t37-tg1 @@ -434,8 +404,8 @@ Name | Comment 10.30.51.88 | s88-t215-tg1 10.30.51.89 | s89-t39t310-tg1 10.30.51.90 | s90-t311t312-tg1 -10.30.51.91 | s58-nomad -10.30.51.92 | s59-nomad +10.30.51.91 | s91-nomad +10.30.51.92 | s92-nomad 10.30.51.93 | s93-t39-sut1 10.30.51.94 | s94-t39-sut2 10.30.51.255 | Broadcast @@ -445,10 +415,6 @@ Name | Comment 10.32.8.11 | s29-t26-sut1 10.32.8.12 | s30-t35-sut1 10.32.8.13 | s31-t35-sut2 -10.32.8.14 | s46-nomad -10.32.8.15 | s47-nomad -10.32.8.16 | s48-nomad -10.32.8.17 | s57-nomad 10.32.8.18 | s33-t27-sut1 10.32.8.19 | s34-t27-tg1 10.32.8.20 | s35-t28-sut1 @@ -797,28 +763,38 @@ FD.io CSIT lab contains following server types: - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. + - no cards - Numa1: - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - - Quantity: 1 + - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node topologies. - Main HW configuration: - - Chassis: TBD - - Motherboard: TBD - - Processors: n* TBD - - RAM Memory: n* TBD - - Disks: TBD + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Motherboard: Mt.Jade Motherboard + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - NICs configuration: - Numa0: - - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. - Numa1: - - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -21. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. + - no cards. +21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - Main HW configuration: + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 +22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -838,7 +814,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. +23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. - Quantity: 8. - Physical connectivity: - IPMI and host management ports. @@ -858,7 +834,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. +24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -878,7 +854,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. +25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -898,7 +874,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. +26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -918,30 +894,20 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. -26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - Main HW configuration: - - Chassis: Gigabyte R152-P30-00 1U - - Motherboard: MP32-AR1-00 - - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1) - - RAM Memory: 4* 16GB RDIMM-3200MHz - - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node testbed topology. - Main HW configuration: - - Chassis: ?. - - Motherboard: ?. - - Processors: ?* Intel Atom P5362B 2.2 GHz. - - RAM Memory: ?* ?GB DDR4-2933. + - Chassis: Intel JACOBSVILLE SDP. + - Motherboard: Intel JACOBSVILLE E63448-400. + - Processors: 1* Intel Atom P5362B 2.2 GHz. + - RAM Memory: 2* 16GB DDR4-2933. - Disks: ?* ? SATA SSD. - NICs configuration: - Numa0: (x16, PCIe3.0 lane) - - PCIe Slot yy:00.xx: ?. + - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. ``` ### Naming Convention @@ -1054,123 +1020,6 @@ connectivity and wiring across defined CSIT testbeds: - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 2-Node-Skylake Servers (2n-skx) PROD - -``` -- SUT [Server-Type-B1]: - - testbedname: testbed21. - - hostname: s3-t21-sut1. - - IPMI IP: 10.30.50.41 - - Host IP: 10.30.51.44 - - portnames: - - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- TG [Server-Type-B2]: - - testbedname: testbed21. - - hostname: s4-t21-tg1. - - IPMI IP: 10.30.50.42 - - Host IP: 10.30.51.45 - - portnames: - - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- SUT [Server-Type-B1]: - - testbedname: testbed22. - - hostname: s5-t22-sut1. - - IPMI IP: 10.30.50.49 - - Host IP: 10.30.51.52 - - portnames: - - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- TG [Server-Type-B2]: - - testbedname: testbed22. - - hostname: s6-t22-tg1. - - IPMI IP: 10.30.50.50 - - Host IP: 10.30.51.53 - - portnames: - - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- SUT [Server-Type-B1]: - - testbedname: testbed23. - - hostname: s7-t23-sut1. - - IPMI IP: 10.30.50.51 - - Host IP: 10.30.51.54 - - portnames: - - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- TG [Server-Type-B2]: - - testbedname: testbed23. - - hostname: s8-t23-tg1. - - IPMI IP: 10.30.50.52 - - Host IP: 10.30.51.55 - - portnames: - - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- SUT [Server-Type-B1]: - - testbedname: testbed24. - - hostname: s9-t24-sut1. - - IPMI IP: 10.30.50.53 - - Host IP: 10.30.51.56 - - portnames: - - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- TG [Server-Type-B2]: - - testbedname: testbed24. - - hostname: s10-t24-tg1. - - IPMI IP: 10.30.50.54 - - Host IP: 10.30.51.57 - - portnames: - - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -``` - #### 2-Node-Denverton Servers (2n-dnv) PROD Note: ServerB28 (TG) is shared between testbed26 & testbed35 @@ -1380,8 +1229,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. - TG [Server-Type-E31]: @@ -1529,91 +1376,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` -#### 3-Node-Skylake Servers (3n-skx) PROD - -``` -- ServerB11 [Server-Type-B1]: - - testbedname: testbed31. - - hostname: s11-t31-sut1. - - IPMI IP: 10.30.50.43 - - Host IP: 10.30.51.46 - - portnames: - - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- ServerB12 [Server-Type-B1]: - - testbedname: testbed31. - - hostname: s12-t31-sut2. - - IPMI IP: 10.30.50.44 - - Host IP: 10.30.51.47 - - portnames: - - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE. - - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE. - - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE. - - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- ServerB13 [Server-Type-B2]: - - testbedname: testbed31. - - hostname: s13-t31-tg1. - - IPMI IP: 10.30.50.45 - - Host IP: 10.30.51.48 - - portnames: - - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- ServerB14 [Server-Type-B1]: - - testbedname: testbed32. - - hostname: s14-t32-sut1. - - IPMI IP: 10.30.50.55 - - Host IP: 10.30.51.58 - - portnames: - - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- ServerB15 [Server-Type-B1]: - - testbedname: testbed32. - - hostname: s15-t32-sut2. - - IPMI IP: 10.30.50.56 - - Host IP: 10.30.51.59 - - portnames: - - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE. - - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE. - - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE. - - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. -- ServerB16 [Server-Type-B2]: - - testbedname: testbed32. - - hostname: s16-t32-tg1. - - IPMI IP: 10.30.50.57 - - Host IP: 10.30.51.60 - - portnames: - - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -``` - #### 3-Node-Rangeley Servers (3n-rng) VERIFY Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. @@ -1695,8 +1457,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 #### 3-Node-Altra Servers (3n-alt) PROD -Note: Server64 (TG) is shared between testbed34 & testbed36 - ``` - SUT [Server-Type-E23]: - testbedname: testbed34. @@ -1704,28 +1464,32 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - IPMI IP: 10.30.50.72 - Host IP: 10.30.51.72 - portnames: - - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE. - - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE. + - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s63-t34-sut2. - IPMI IP: 10.30.50.73 - Host IP: 10.30.51.73 - portnames: - - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE. - - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE. + - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. - TG [Server-Type-F4]: - testbedname: testbed34. - - hostname: s64-t34t36-tg1. + - hostname: s64-t34-tg1. - IPMI IP: 10.30.50.74 - Host IP: 10.30.51.74 - portnames: - - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` #### 3-Node-Denverton Servers (3n-dnv) PROD @@ -1851,24 +1615,30 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - IPMI IP: 10.30.50.93 - Host IP: 10.30.51.93 - portnames: - - s93-t39-sut1-c1/p1 - 100GE-port1 e810-DA2-2p100GE. - - s93-t39-sut1-c1/p2 - 100GE-port2 e810-DA2-2p100GE. + - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE. + - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE. - ServerG1 [Server-Type-G1]: - testbedname: testbed39. - hostname: s94-t39-sut2. - IPMI IP: 10.30.50.94 - Host IP: 10.30.51.94 - portnames: - - s94-t39-sut2-c1/p1 - 100GE-port1 e810-DA2-2p100GE. - - s94-t39-sut2-c1/p2 - 100GE-port1 e810-DA2-2p100GE. + - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - ServerF4 [Server-Type-F4]: - testbedname: testbed39. - hostname: s89-t39t310-tg1. - IPMI IP: 10.30.50.89 - Host IP: 10.30.51.89 - portnames: - - s89-t39t310-tg1-c6/p1 - 100GE-port1 e810-DA2-2p100GE. - - s89-t39t310-tg1-c6/p2 - 100GE-port1 e810-DA2-2p100GE. + - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. ``` ### Per Testbed Wiring @@ -1928,63 +1698,6 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` -#### 2-Node-Skylake Wiring (2n-skx) PROD - -``` -- testbed21: - - ring1 10GE-ports x710-4p10GE on SUT: - - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1. - - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3. - - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. - - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. - - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. - - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. -- testbed22: - - ring1 10GE-ports x710-4p10GE on SUT: - - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. - - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3. - - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. - - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. - - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. - - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. -- testbed23: - - ring1 10GE-ports x710-4p10GE on SUT: - - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. - - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3. - - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. - - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. - - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. - - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. -- testbed24: - - ring1 10GE-ports x710-4p10GE on SUT: - - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. - - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3. - - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. - - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. - - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. - - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. -``` - #### 2-Node-Denverton Wiring (2n-dnv) PROD ``` @@ -2162,51 +1875,6 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. ``` -#### 3-Node-Skylake Wiring (3n-skx) PROD - -``` -- testbed31: - - ring1 10GE-ports x710-4p10GE on SUTs: - - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1. - - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2. - - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3. - - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4. - - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1. - - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2. - - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1. - - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2. - - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2. - - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4. -- testbed32: - - ring1 10GE-ports x710-4p10GE on SUTs: - - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1. - - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2. - - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3. - - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4. - - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1. - - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2. - - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1. - - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2. - - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2. - - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4. -``` - #### 3-Node-Rangeley Wiring (3n-rng) VERIFY ``` @@ -2232,13 +1900,9 @@ To be completed. ``` - testbed34: - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: - - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2. - - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2. - - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1. - - ring2 100GE-ports ConnectX5-2p100GE on SUTs: - - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2. - - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2. - - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1. + - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. + - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. + - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. ``` #### 3-Node-Denverton Wiring (3n-dnv) PROD @@ -2296,10 +1960,13 @@ To be completed. ``` - testbed39: - - ring1 100GE-ports e810-DA2-2p100GE on SUTs and TG: + - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG: - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. + - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3. + - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4. + - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. ``` ## Inventory @@ -2338,11 +2005,20 @@ To be completed. - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. - - 2 * Ampere Altra - - Chassis: TBD - - Processors: TBD - - RAM Memory: TBD - - Disks: TBD +2. Arm Neoverse N1 servers + - 2 * Ampere Altra (Performance) + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 + - 2 * Ampere Altra (Build) + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 ``` ### Xeon and Atom Servers @@ -2367,15 +2043,13 @@ To be completed. ``` 1. 10GE NICs - - 14 * Intel® Ethernet Converged Network Adapter X710-DA4 - - 6 * Intel® Ethernet Converged Network Adapter X710-DA2 - - 6 * Intel® Ethernet Converged Network Adapter X520-DA2 + - ? 2. 25GE NICs - - 12 * Intel® Ethernet Network Adapter XXV710-DA2 + - ? 3. 40GE NICs - - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2 + - ? 4. 100GE NICs - - 4 * mcx556a-edat NICs (not on site yet, in transit) + - ? ``` ### Pluggables and Cables @@ -2384,27 +2058,26 @@ Pluggables: ``` 1. 10GE SFP+ - - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics - - 80 * 10G SR optic (generic, "Intel" compatible branded) + - ? 2. 25GE SFP28 - - None + - ? 3. 40GE QSFP+ - - None + - ? 4. 100GE - - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit) + - ? ``` Standalone cables: ``` 1. 10GE - - None + - ? 2. 25GE - - None + - ? 3. 40GE QSFP+ - - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable + - ? 4. 100GE - - None + - ? ``` ### Other Parts