X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=2c1cd38636948ccda42d8c8ac79a1f74ebe54675;hb=cd417be7f836eb9346fad4f87bd4f75dc1d9a429;hp=8143b7bf726ad4a52601ffdb7439bc45a00f51d4;hpb=75351e349449d6c397cb830828dc4f55883511a3;p=csit.git diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 8143b7bf72..2c1cd38636 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -95,7 +95,8 @@ hosted by LFN FD.io CSIT project. 15. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 16. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 17. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 6 - Totals: 32 41 21.5 4 19 1 2 3 3 2 2 7 2 14.5 +18. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0 + Totals: 34 43 21.5 4 19 1 2 3 3 2 4 7 2 14.5 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -325,6 +326,8 @@ Name | Comment 10.30.50.88 | s78-t215-tg1 10.30.50.89 | s79-t39t310-tg1 10.30.50.90 | s80-t311t312-tg1 +10.30.50.91 | s58-nomad +10.30.50.92 | s59-nomad 10.30.50.255 | Broadcast 10.30.55.0 | network 10.30.55.1 | Router @@ -417,6 +420,8 @@ Name | Comment 10.30.51.88 | s78-t215-tg1 10.30.51.89 | s79-t39t310-tg1 10.30.51.90 | s80-t311t312-tg1 +10.30.51.91 | s58-nomad +10.30.51.92 | s59-nomad 10.30.51.255 | Broadcast 10.32.8.0 | network 10.32.8.1 | Router @@ -663,7 +668,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. + - PCIe Slot6 86:00.xx: e810-2p100GE Intel. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. @@ -683,13 +688,13 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. + - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - PCIe Slot10 d8:00.xx: empty. 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - - CIMC and host management ports. + - IPMI and host management ports. - no NIC ports, standalone setup. - Main HW configuration: - Chassis: SuperMicro 1029P-WTRT. @@ -897,6 +902,16 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 d8:00.xx: empty. +26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - Main HW configuration: + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1) + - RAM Memory: 4* 16GB RDIMM-3200MHz + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 ``` ### Naming Convention @@ -1217,8 +1232,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE. - - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: @@ -1249,8 +1266,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE. - - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: @@ -1281,8 +1300,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE. - - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. ``` @@ -1949,9 +1968,12 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT: + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. + - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. - testbed28: - ring1 10GE-ports x710-4p10GE on SUT: - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. @@ -1965,9 +1987,12 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT: + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. + - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. - testbed29: - ring1 10GE-ports x710-4p10GE on SUT: - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. @@ -1981,7 +2006,7 @@ Note: Server64 (TG) is shared between testbed34 & testbed36 - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. - - ring6 100GE-ports e810-2p100GE on SUT: + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. ```