X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=365eaddb591103a588b7fc168778ed8a7b7f60eb;hb=324f01417f17a5347c102179f3d2277a77b116ce;hp=69efbae272f88aae6d8f646481c9753f096c0936;hpb=2fb828367638255e3163628191cc904da75b66e2;p=csit.git diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 69efbae272..365eaddb59 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -11,7 +11,7 @@ 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) - 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) + 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) @@ -26,30 +26,31 @@ 1. [Testbeds Configuration](#testbeds-configuration) 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) - 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip) + 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod) 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod) - 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo) + 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod) 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) - 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup) - 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup]) - 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod) + 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) + 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) + 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) - 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-wip) + 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) 1. [Per Testbed Wiring](#per-testbed-wiring) 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) - 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip) - 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup) + 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) + 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod) 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod) - 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo) + 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod) 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) - 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup]) + 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) + 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod) 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo) - 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-wip) + 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) 1. [Inventory](#inventory) 1. [Appliances](#appliances) 1. [Arm Servers](#arm-servers) @@ -69,22 +70,21 @@ hosted by LFN FD.io CSIT project. ``` #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2 - 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0 + 1. 1-Node-Haswell nomad hsw --- 4 4 0 4 0 0 0 0 0 0 0 0 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 - 3. 1-Node-Thunderx2 idle tx2 na 1 1 0 0 0 0 0 0 1 0 0 0 - 4. 1-Node-Thunderx2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 + 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0 + 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 -10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0 -11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 -12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 -13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 -14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 -15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2 - Totals: 27 36 16.5 12 18.5 1 2 3 3 2 7 2 +10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 +11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 +12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 +13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 +14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2 + Totals: 25 31 15 4 19 1 2 3 3 2 7 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -141,6 +141,13 @@ one TG (Server-Type-D2) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. +### 2-Node-ThunderX2 Arm Marvell (2x-tx2) + +Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and +one TG (Server-Type-B12) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Haswell Xeon Intel (3n-hsw) Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one @@ -157,7 +164,7 @@ Used for FD.io performance tests. ### 3-Node-TaiShan Arm Huawei (3n-tsh) Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one -TG (Server-Type-B2) connected in a 3-node circular topology +TG (Server-Type-B12) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -226,25 +233,16 @@ Name | Comment 10.30.50.13 | LF Reserved 10.30.50.14 | LF Reserved 10.30.50.15 | LF Reserved -10.30.50.16 | t1-tg1 -10.30.50.17 | t1-sut1 -10.30.50.18 | t1-sut2 -10.30.50.20 | t2-tg1 -10.30.50.21 | t2-sut1 -10.30.50.22 | t2-sut2 -10.30.50.24 | t3-tg1 -10.30.50.25 | t3-sut1 -10.30.50.26 | t3-sut-2 10.30.50.28 | s41-nomad 10.30.50.29 | s39-nomad 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0 10.30.50.30 | s40-nomad 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2 -10.30.50.32 | s42-nomad (formerly nomad1) -10.30.50.33 | s43-nomad (formerly nomad2) -10.30.50.34 | s44-nomad (formerly nomad3) -10.30.50.35 | s45-nomad (formerly nomad4) +10.30.50.32 | s42-nomad +10.30.50.33 | s43-nomad +10.30.50.34 | s44-nomad +10.30.50.35 | s45-nomad 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 10.30.50.38 | fdio-marvell-dev @@ -273,7 +271,7 @@ Name | Comment 10.30.50.66 | s51-nomad 10.30.50.67 | s49-nomad 10.30.50.68 | s50-nomad -10.30.50.69 | s27-t13-sut +10.30.50.69 | s27-t34-sut1 10.30.50.70 | s55-t36-sut1 10.30.50.71 | s56-t37-sut1 10.30.50.255 | Broadcast @@ -285,10 +283,10 @@ n/a | s21-t34-sut2 10.30.55.11 | s29-t26-sut1 10.30.55.12 | s30-t35-sut1 10.30.55.13 | s31-t35-sut2 -10.30.55.14 | s46-nomad (formerly server-type-c4-1) -10.30.55.15 | s47-nomad (formerly server-type-c4-2) -10.30.55.16 | s48-nomad (formerly server-type-c4-3) -10.30.55.17 | s32-t14-sut1 +10.30.55.14 | s46-nomad +10.30.55.15 | s47-nomad +10.30.55.16 | s48-nomad +10.30.55.17 | s57-nomad 10.30.55.18 | s33-t27-sut1 10.30.55.19 | s34-t27-tg1 10.30.55.20 | s35-t28-sut1 @@ -312,37 +310,19 @@ Name | Comment 10.30.51.6 | LF Reserved 10.30.51.7 | LF Reserved 10.30.51.8 | LF Reserved -10.30.51.9 | s22-t35-sut1 (netgate-1) -10.30.51.10 | s23-t35-sut2 (netgate-2) -10.30.51.11 | s24-t35-sut3 (netgate-3) -10.30.51.12 | softiron-1 (decommissioned) -10.30.51.13 | softiron-2 (decommissioned) -10.30.51.14 | softiron-3 (decommissioned) 10.30.51.15 | LF Reserved -10.30.51.16 | t1-tg1 -10.30.51.17 | t1-sut1 -10.30.51.18 | t1-sut2 -10.30.51.20 | t2-tg1 -10.30.51.21 | t2-sut1 -10.30.51.22 | t2-sut2 -10.30.51.24 | t3-tg1 -10.30.51.25 | t3-sut1 -10.30.51.26 | t3-sut-2 10.30.51.28 | s41-nomad 10.30.51.29 | s39-nomad 10.30.51.30 | s40-nomad -10.30.51.32 | s42-nomad (formerly nomad1) -10.30.51.33 | s43-nomad (formerly nomad2) -10.30.51.34 | s44-nomad (formerly nomad3) -10.30.51.35 | s45-nomad (formerly nomad4) +10.30.51.32 | s42-nomad +10.30.51.33 | s43-nomad +10.30.51.34 | s44-nomad +10.30.51.35 | s45-nomad 10.30.51.36 | s17-t33-sut1 10.30.51.37 | s18-t33-sut2 10.30.51.38 | fdio-marvell-dev 10.30.51.39 | s53-nomad 10.30.51.40 | s54-nomad -10.30.51.41 | s20-t34-sut1 (decommissioned) -10.30.51.42 | s21-t34-sut2 (decommissioned) -10.30.51.43 | fdio-mcbin3 (decommissioned) 10.30.51.44 | s3-t21-sut1 10.30.51.45 | s4-t21-tg1 10.30.51.46 | s11-t31-sut1 @@ -366,12 +346,10 @@ Name | Comment 10.30.51.66 | s51-nomad 10.30.51.67 | s49-nomad 10.30.51.68 | s50-nomad -10.30.51.69 | s27-t13-sut1 +10.30.51.69 | s27-t34-sut1 10.30.51.70 | s55-t36-sut1 10.30.51.71 | s56-t37-sut1 -10.30.51.72-10.30.51.105 | FREE -10.30.51.106-10.30.51.180 | FREE -10.30.51.181-10.30.51.254 | FREE +10.30.51.72-10.30.51.254 | FREE 10.30.51.255 | Broadcast 10.32.8.0 | network 10.32.8.1 | Router @@ -379,10 +357,10 @@ Name | Comment 10.32.8.11 | s29-t26-sut1 10.32.8.12 | s30-t35-sut1 10.32.8.13 | s31-t35-sut2 -10.32.8.14 | s46-nomad (formerly server-type-c4-1) -10.32.8.15 | s47-nomad (formerly server-type-c4-2) -10.32.8.16 | s48-nomad (formerly server-type-c4-3) -10.32.8.17 | s32-t14-sut1 +10.32.8.14 | s46-nomad +10.32.8.15 | s47-nomad +10.32.8.16 | s48-nomad +10.32.8.17 | s57-nomad 10.32.8.18 | s33-t27-sut1 10.32.8.19 | s34-t27-tg1 10.32.8.20 | s35-t28-sut1 @@ -411,13 +389,13 @@ FD.io CSIT lab contains following server types: - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. - NICs configuration: - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes) - - PCIe Slot1: Cisco VIC 1385 2p40GE. - - PCIe Slot2: Intel NIC x520 2p10GE. + - PCIe Slot1: empty. + - PCIe Slot2: empty. - PCIe Slot3: empty. - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes) - - PCIe Slot4: Intel NIC xl710 2p40GE. - - PCIe Slot5: Intel NIC x710 2p10GE. - - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill) + - PCIe Slot4: empty. + - PCIe Slot5: empty. + - PCIe Slot6: empty - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes). 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. - Quantity: 3 servers. @@ -430,14 +408,14 @@ FD.io CSIT lab contains following server types: - RAM Memory: 16* 32GB DDR4-2133MHz. - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. - NICs configuration: - - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes) - - PCIe Slot1: Intel NIC xl710 2p40GE. - - PCIe Slot2: Intel NIC x710 2p10GE. - - PCIe Slot3: Intel NIC x710 2p10GE. - - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - - PCIe Slot4: Intel NIC xl710 2p40GE. - - PCIe Slot5: Intel NIC x710 2p10GE. - - PCIe Slot6: Intel NIC x710 2p10GE. + - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes) + - PCIe Slot1: empty. + - PCIe Slot2: empty. + - PCIe Slot3: empty. + - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes) + - PCIe Slot4: empty. + - PCIe Slot5: empty. + - PCIe Slot6: empty - MLOM slot: empty. 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. - Quantity: 3 servers. @@ -502,7 +480,7 @@ FD.io CSIT lab contains following server types: - NIC ports connected into 3-node topology. - Main HW configuration: - Chassis: Huawei TaiShan 2280. - - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72 + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - RAM Memory: 8* 16GB DDR4-2400MT/s - Disks: 1* 4TB SATA HDD - NICs configuration: @@ -580,7 +558,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle). +11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -588,15 +566,14 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: Gigabyte R181-T90 1U - Motherboard: MT91-FS1 - - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz + - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - - PCIe Slot1 05:00.xx: XL710-QDA2. - - PCIe Slot3 08:00.xx: XL710-QDA2. + - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. - Numa1: - - PCIe Slot6 85:00.xx: XL710-QDA2. + - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: @@ -611,7 +588,7 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports -13. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests. +13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -619,7 +596,7 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: GIGABYTE Rack Mount - Motherboard: MT91-FS4-00 - - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz + - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - RAM Memory: 16 * 16GB DIMM - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - NICs configuration: @@ -629,8 +606,28 @@ FD.io CSIT lab contains following server types: - Numa1: - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. +14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: --- + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. +15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -650,7 +647,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. +16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - IPMI and host management ports. @@ -670,7 +667,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. +17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -690,7 +687,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. +18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - CIMC and host management ports. @@ -706,8 +703,7 @@ FD.io CSIT lab contains following server types: - no cards. - Numa1: - no cards. - -18. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. +19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -722,7 +718,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -19. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. +20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -797,7 +793,7 @@ connectivity and wiring across defined CSIT testbeds: - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 1-Node-Thunderx2 Servers (1n-tx2) WIP +#### 1-Node-ThunderX2 Servers (1n-tx2) PROD ``` - SUT [Server-Type-B11]: @@ -814,7 +810,6 @@ connectivity and wiring across defined CSIT testbeds: - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - SUT [Server-Type-B11]: - testbedname: testbed37 - hostname: s56-t37-sut1 @@ -951,7 +946,7 @@ connectivity and wiring across defined CSIT testbeds: - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. ``` -#### 2-Node-Denverton Servers (2n-dnv) WIP +#### 2-Node-Denverton Servers (2n-dnv) PROD Note: ServerB28 (TG) is shared between testbed26 & testbed35 @@ -1011,7 +1006,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s26-t25-tg1-p4 - 10GE-port4. ``` -#### 2-Node-Cascadelake Servers (2n-clx) SETUP +#### 2-Node-Cascadelake Servers (2n-clx) PROD ``` - SUT [Server-Type-C2]: @@ -1026,6 +1021,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-C3]: @@ -1040,6 +1037,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE. + - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE. - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: @@ -1054,6 +1053,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-C3]: @@ -1068,6 +1069,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE. + - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE. - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - SUT [Server-Type-C2]: @@ -1082,8 +1085,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. + - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - TG [Server-Type-C3]: - testbedname: testbed29. - hostname: s38-t29-tg1. @@ -1096,11 +1101,13 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. + - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE. + - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. ``` -#### 2-Node-Zen2 Servers (2n-zn2) SETUP +#### 2-Node-Zen2 Servers (2n-zn2) PROD ``` - SUT [Server-Type-D1]: @@ -1133,159 +1140,39 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. ``` -#### 3-Node-Haswell Servers (3n-hsw) PROD +#### 2-Node-ThunderX2 Servers (2x-tx2) PROD + +Note: Server19 (TG) is shared between testbed33 & testbed34 ``` - 1. SUT [Server-Type-A1]: - - testbedname: testbed1. - - hostname: t1-sut1. - - CIMC IP: 10.30.50.17 - - Host IP: 10.30.51.17 - - portnames: - - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 2. SUT [Server-Type-A1]: - - testbedname: testbed1. - - hostname: t1-sut2. - - CIMC IP: 10.30.50.18 - - Host IP: 10.30.51.18 +- SUT [Server-Type-B9]: + - testbedname: testbed34. + - hostname: s27-t34-sut1. + - IPMI IP: 10.30.50.69 + - Host IP: 10.30.51.69 - portnames: - - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 3. TG [Server-Type-A2]: - - testbedname: testbed1. - - hostname: t1-tg1. - - CIMC IP: 10.30.50.16 - - Host IP: 10.30.51.16 - - portnames: - - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 4. SUT [Server-Type-A1]: - - testbedname: testbed2. - - hostname: t2-sut1. - - CIMC IP: 10.30.50.21 - - Host IP: 10.30.51.21 - - portnames: - - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 5. SUT [Server-Type-A1]: - - testbedname: testbed2. - - hostname: t2-sut2. - - CIMC IP: 10.30.50.22 - - Host IP: 10.30.51.22 - - portnames: - - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 6. TG [Server-Type-A2]: - - testbedname: testbed2. - - hostname: t2-tg1. - - CIMC IP: 10.30.50.20 - - Host IP: 10.30.51.20 - - portnames: - - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 7. SUT [Server-Type-A1]: - - testbedname: testbed3. - - hostname: t3-sut1. - - CIMC IP: 10.30.50.25 - - Host IP: 10.30.51.25 - - portnames: - - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 8. SUT [Server-Type-A1]: - - testbedname: testbed3. - - hostname: t3-sut2. - - CIMC IP: 10.30.50.26 - - Host IP: 10.30.51.26 - - portnames: - - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 9. TG [Server-Type-A2]: - - testbedname: testbed3. - - hostname: t3-tg1. - - CIMC IP: 10.30.50.24 - - Host IP: 10.30.51.24 + - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE. +- TG [Server-Type-B12]: + - testbedname: testbed33 and testbed34. + - hostname: s19-t33t34-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 - portnames: - - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` #### 3-Node-Skylake Servers (3n-skx) PROD @@ -1413,8 +1300,10 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. #### 3-Node-Taishan Servers (3n-tsh) PROD +Note: Server19 (TG) is shared between testbed33 & testbed34 + ``` -- ServerB17 [Server-Type-B3]: +- SUT [Server-Type-B3]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 @@ -1424,7 +1313,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB18 [Server-Type-B3]: +- SUT [Server-Type-B3]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 @@ -1434,7 +1323,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB19 [Server-Type-B2]: +- TG [Server-Type-B12]: - testbedname: testbed33 and testbed34. - hostname: s19-t33t34-tg1. - IPMI IP: 10.30.50.46 @@ -1446,13 +1335,15 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` -#### 3-Node-Denverton Servers (3n-dnv) WIP +#### 3-Node-Denverton Servers (3n-dnv) PROD ``` - ServerB30 [Server-Type-B10]: @@ -1490,7 +1381,11 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring3 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. + - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4. + - ring5 100GE-ports e810-2p100GE: + - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1. + - ring6 100GE-ports e810-2p100GE: + - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2. - testbed12: - ring1 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. @@ -1499,10 +1394,14 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring3 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. + - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4. + - ring5 100GE-ports e810-2p100GE: + - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1. + - ring6 100GE-ports e810-2p100GE: + - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. ``` -#### 1-Node-Thunderx2 Wiring (1n-tx2) WIP +#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD ``` - testbed36: @@ -1526,7 +1425,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2. ``` -#### 1-Node-Cascadelake Wiring (1n-clx) SETUP +#### 1-Node-Cascadelake Wiring (1n-clx) PROD ``` - testbed14: @@ -1585,7 +1484,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. ``` -#### 2-Node-Denverton Wiring (2n-dnv) WIP +#### 2-Node-Denverton Wiring (2n-dnv) PROD ``` - testbed26: @@ -1627,6 +1526,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT: + - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. + - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. - testbed28: - ring1 10GE-ports x710-4p10GE on SUT: - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. @@ -1637,9 +1539,12 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT: + - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. + - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. - testbed29: - ring1 10GE-ports x710-4p10GE on SUT: - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. @@ -1650,12 +1555,15 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - ring4 100GE-ports ConnectX5-2p100GE on SUT: - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. + - ring6 100GE-ports e810-2p100GE on SUT: + - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. + - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. ``` -#### 2-Node-Zen2 Wiring (2n-zen2) SETUP +#### 2-Node-Zen2 Wiring (2n-zn2) PROD ``` - testbed210: @@ -1673,80 +1581,13 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. ``` -#### 3-Node-Haswell Wiring (3n-hsw) PROD - -``` - 1. testbed1: - - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - - t1-tg1-c1/p1 to t1-sut1-c1/p2. - - t1-sut1-c1/p1 to t1-sut2-c1/p2. - - t1-sut2-c1/p1 to t1-tg1-c1/p2. - - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - - t1-tg1-c2/p1 to t1-sut1-c2/p2. - - t1-sut1-c2/p1 to t1-sut2-c2/p2. - - t1-sut2-c2/p1 to t1-tg1-c2/p2. - - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - - t1-tg1-c4/p1 to t1-sut1-c4/p2. - - t1-sut1-c4/p1 to t1-sut2-c4/p2. - - t1-sut2-c4/p1 to t1-tg1-c4/p2. - - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - - t1-tg1-c5/p1 to t1-sut1-c5/p2. - - t1-sut1-c5/p1 to t1-sut2-c5/p2. - - t1-sut2-c5/p1 to t1-tg1-c5/p2. - - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - - t1-tg1-c2/p1 to t1-sut1-cm/p2. - - t1-sut1-cm/p1 to t1-sut2-cm/p2. - - t1-sut2-cm/p1 to t1-tg1-c2/p2. - - TG loopback ports Intel NIC x710 2p10GE - - t1-tg1-c6/p1 to t1-tg1-c6/p2. - - 2. testbed2: - - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - - t2-tg1-c1/p1 to t2-sut1-c1/p2. - - t2-sut1-c1/p1 to t2-sut2-c1/p2. - - t2-sut2-c1/p1 to t2-tg1-c1/p2. - - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - - t2-tg1-c2/p1 to t2-sut1-c2/p2. - - t2-sut1-c2/p1 to t2-sut2-c2/p2. - - t2-sut2-c2/p1 to t2-tg1-c2/p2. - - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - - t2-tg1-c4/p1 to t2-sut1-c4/p2. - - t2-sut1-c4/p1 to t2-sut2-c4/p2. - - t2-sut2-c4/p1 to t2-tg1-c4/p2. - - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - - t2-tg1-c5/p1 to t2-sut1-c5/p2. - - t2-sut1-c5/p1 to t2-sut2-c5/p2. - - t2-sut2-c5/p1 to t2-tg1-c5/p2. - - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - - t2-tg1-c2/p1 to t2-sut1-cm/p2. - - t2-sut1-cm/p1 to t2-sut2-cm/p2. - - t2-sut2-cm/p1 to t2-tg1-c2/p2. - - TG loopback ports Intel NIC x710 2p10GE - - t2-tg1-c6/p1 to t2-tg1-c6/p2. - - 3. testbed3: - - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - - t3-tg1-c1/p1 to t3-sut1-c1/p2. - - t3-sut1-c1/p1 to t3-sut2-c1/p2. - - t3-sut2-c1/p1 to t3-tg1-c1/p2. - - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - - t3-tg1-c2/p1 to t3-sut1-c2/p2. - - t3-sut1-c2/p1 to t3-sut2-c2/p2. - - t3-sut2-c2/p1 to t3-tg1-c2/p2. - - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - - t3-tg1-c4/p1 to t3-sut1-c4/p2. - - t3-sut1-c4/p1 to t3-sut2-c4/p2. - - t3-sut2-c4/p1 to t3-tg1-c4/p2. - - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - - t3-tg1-c5/p1 to t3-sut1-c5/p2. - - t3-sut1-c5/p1 to t3-sut2-c5/p2. - - t3-sut2-c5/p1 to t3-tg1-c5/p2. - - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - - t3-tg1-c2/p1 to t3-sut1-cm/p2. - - t3-sut1-cm/p1 to t3-sut2-cm/p2. - - t3-sut2-cm/p1 to t3-tg1-c2/p2. - - TG loopback ports Intel NIC x710 2p10GE - - t3-tg1-c6/p1 to t3-tg1-c6/p2. +#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD + +``` +- testbed34: + - ring1 10GE-ports x520-2p10GE on SUTs: + - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1. + - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2. ``` #### 3-Node-Skylake Wiring (3n-skx) PROD @@ -1814,7 +1655,7 @@ To be completed. - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1. ``` -#### 3-Node-Denverton Wiring (3n-dnv) WIP +#### 3-Node-Denverton Wiring (3n-dnv) PROD ``` - testbed35: @@ -1851,17 +1692,17 @@ To be completed. 1. Arm Cortex A-72 servers - 2 * ThunderX2 (VPP Device) - Chassis: GIGABYTE Rack Mount - - Processors: 2* ThunderX2 CN9980 ~ 128* ThunderX2 + - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2 - RAM Memory: 16* 16GB DIMM - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - 1 * ThunderX2 (Idle) - - Chassis: Marvell ThunderX2 - - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2. + - 1 * ThunderX2 (Performance) + - Chassis: GIGABYTE Rack Mount + - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2. - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - 2 * Huawei TaiShan 2280. - Chassis: Huawei TaiShan 2280. - - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. ```