X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=7d4f0e001aa186372cffb3d985dba383d8f5a1b4;hb=HEAD;hp=cade63a6f55ec62dd051caafd97ba1efd251dea4;hpb=5e7c4ced1ac46f93c918d070b19ad330294ad269;p=csit.git diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md deleted file mode 100644 index cade63a6f5..0000000000 --- a/docs/lab/testbed_specifications.md +++ /dev/null @@ -1,1867 +0,0 @@ -# FD.io CSIT Testbed Specifications - -1. [Purpose](#purpose) -1. [Testbeds Overview](#testbeds-overview) - 1. [Summary List](#summary-list) - 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) - 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) - 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx) - 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) - 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) - 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) - 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) - 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx) - 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) - 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) - 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt) - 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx) - 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr) - 1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr) - 1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr) -1. [Server Management](#server-management) - 1. [Addressing](#addressing) -1. [Server Specifications](#server-specifications) - 1. [Server Types](#server-types) - 1. [Naming Convention](#naming-convention) -1. [Testbeds Configuration](#testbeds-configuration) - 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) - 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) - 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod) - 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) - 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) - 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) - 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) - 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) - 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) - 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) - 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) - 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod) - 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod) - 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod) - 1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod) - 1. [Per Testbed Wiring](#per-testbed-wiring) - 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) - 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) - 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod) - 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) - 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) - 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) - 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) - 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) - 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo) - 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) - 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod) - 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod) - 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod) - 1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod) - -## Purpose - -This note includes specification of the physical testbed infrastructure -hosted by LFN FD.io CSIT project. - -## Testbeds Overview - -### Summary List - -``` - #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr - 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 - 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0 - 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 - 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 - 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 - 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 - 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 -10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 -11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 -12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 -13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 -13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 - Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 -``` - -### 1-Node-Skylake Xeon Intel (1n-skx) - -Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC -ports connected back-to-back ([Server Types](#server-types)). -Used for FD.io VPP_Device functional driver tests. - -### 1-Node-ThunderX2 Arm Marvell (1n-tx2) - -Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC -ports connected back-to-back ([Server Types](#server-types)). -Used for FD.io VPP_Device functional driver tests. - -### 1-Node-Cascadelake Xeon Intel (1n-clx) - -Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with -NIC ports connected back-to-back ([Server Types](#server-types)). - -Used for FD.io VPP_Device functional driver tests. - -### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) - -Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one -TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node -circular topology ([Server Types](#server-types)). -Used for FD.io TCP/IP and HTTP performance tests. - -### 2-Node-Cascadelake Xeon Intel (2n-clx) - -Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and -one TG (Server-Type-C3) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-Zen2 EPYC AMD (2n-zn2) - -Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and -one TG (Server-Type-D2) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-ThunderX2 Arm Marvell (2x-tx2) - -Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and -one TG (Server-Type-E31) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-Icelake Xeon Intel (2n-icx) - -Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and -one TG (Server-Type-F2) connected in a 2-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-Rangeley Atom Testbeds - -Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one -TG (Server-Type-2) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-TaiShan Arm Huawei (3n-tsh) - -Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one -TG (Server-Type-E31) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-Altra Arm Ampere (3n-alt) - -Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one -TG (Server-Type-F4) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-Icelake Xeon Intel (3n-icx) - -Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one -TG (Server-Type-F3) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 3-Node-SnowRidge Atom Intel (3n-snr) - -Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one -TG (Server-Type-F4) connected in a 3-node circular topology -([Server Types](#server-types)). -Used for FD.io performance tests. - -### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr) - -One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and -one TG (Server-Type-H2) connected in a 2-node physical topology -with NUMA (socket) daisy chaining. For more detail see -[Server Types](#server-types) and [Testbed Topology-TODO](#TODO). -Used for FD.io performance tests in a full system SUT setup with all PCIe -Gen5 x16 lane slots populated with 2p200GbE NICs. - -### 2-Node-SapphireRapids Xeon Intel (2n-spr) - -Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and -one TG (Server-Type-H6) connected in a 2-node circular topology. For more -detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). -Used for FD.io performance tests. - -## Server Management - -### Addressing - -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a -Management port, which are connected to two different VLANs. - -``` -1. LOM (IPMI) VLAN: - - Subnet: 10.30.50.0/24 - - Gateway: 10.30.50.1 - - Broadcast: 10.30.50.255 - - DNS1: 199.204.44.24 - - DNS2: 199.204.47.54 -2. Management Vlan: - - Subnet: 10.30.51.0/24 - - Gateway: 10.30.51.1 - - Broadcast: 10.30.51.255 - - DNS1: 199.204.44.24 - - DNS2: 199.204.47.54 -``` - -To access these hosts, VPN connection is required. - -## Server Specifications - -### Server Types - -FD.io CSIT lab contains following server types: -``` -1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: empty. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - - Quantity: 1. - - Physical connectivity: - - Host management interface: 10/100/1000-BaseT. - - 8-port 10GE SFP+ integrated NIC. - - Main HW configuration: - - Chassis: PS10GE4NG. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: Quad-Core, Intel Processor. - - HW accelerators: FPGA offload. - - RAM Memory: 64GB. - - Disks: 1 * 1 TB, Enterprise Class, High MTBF. - - Physical Interfaces: 4 * 10GE SFP+. - - Operating System: Native IxOS. - - Interface configuration: - - Port-1: 10GE SFP+. - - Port-2: 10GE SFP+. - - Port-3: 10GE SFP+. - - Port-4: 10GE SFP+. -4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - - Quantity: 3 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Gold 6252N 2.3 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: e810-2p100GE Intel. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 2* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. - - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. - - PCIe Slot10 d8:00.xx: empty. -8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - no NIC ports, standalone setup. - - Main HW configuration: - - Chassis: SuperMicro 1029P-WTRT. - - Motherboard: SuperMicro X11DDW-NT. - - Processors: 2* Intel Platinum 8280 2.7 GHz. - - RAM Memory: 12* 16GB DDR4-2933. - - Disks: 4* 1.92TB SATA SSD. - - NICs configuration: - - Numa0: - - no cards. - - Numa1: - - no cards. -9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro AS-1114S-WTRT - - Processors: 1* AMD EPYC 7532 2.4 GHz. - - RAM Memory: 8* 32GB DDR4-2933. - - Disks: 1* 1TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro AS-1114S-WTRT - - Processors: 1* AMD EPYC 7532 2.4 GHz. - - RAM Memory: 8* 32GB DDR4-2933. - - Disks: 1* 1TB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. -11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: GIGABYTE Rack Mount - - Motherboard: MT91-FS4-00 - - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - - RAM Memory: 16 * 16GB DIMM - - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - NICs configuration: - - Numa0: - - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. - - Numa1: - - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. -12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI(?) and host management ports. - - NIC ports connected into 3-node topology. - - Main HW configuration: - - Chassis: Huawei TaiShan 2280. - - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - - RAM Memory: 8* 16GB DDR4-2400MT/s - - Disks: 1* 4TB SATA HDD - - NICs configuration: - - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - - Quantity: 1 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node topologies. - - Main HW configuration: - - Chassis: Gigabyte R181-T90 1U - - Motherboard: MT91-FS1 - - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - - RAM Memory: 4* 32GB RDIMM - - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - - NICs configuration: - - Numa0: - - no cards - - Numa1: - - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. -14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-node topologies. - - Main HW configuration: - - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U - - Motherboard: Mt.Jade Motherboard - - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 - - RAM Memory: 16* 8GB DDR4-3200MT/s - - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - - NICs configuration: - - Numa0: - - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. - - Numa1: - - no cards. -15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - Main HW configuration: - - Chassis: Gigabyte R152-P30-00 1U - - Motherboard: MP32-AR1-00 - - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 - - RAM Memory: 12* 16GB DDR4-3200MT/s - - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 -16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. - - Quantity: 1 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node and 3-node topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. - - Quantity: 8. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node or 3-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. -20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - - Quantity: 3. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node and/or 3-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-740GP-TNRT. - - Motherboard: Super X12DPG-QT6. - - Processors: 2* Intel Platinum 8358 2.6 GHz. - - RAM Memory: 16* 16GB DDR4-3200. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 d8:00.xx: empty. -21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-node testbed topology. - - Main HW configuration: - - Chassis: Intel JACOBSVILLE SDP. - - Motherboard: Intel JACOBSVILLE E63448-400. - - Processors: 1* Intel Atom P5362B 2.2 GHz. - - RAM Memory: 2* 16GB DDR4-2933. - - Disks: ?* ? SATA SSD. - - NICs configuration: - - Numa0: (x16, PCIe3.0 lane) - - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. -23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot11 d8:00.xx: empty. -24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot10 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot11 d8:00.xx: empty. -25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - - Quantity: 1. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 3-numa-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot10 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: empty. - - PCIe Slot9 af:00.xx: empty. - - PCIe Slot11 d8:00.xx: empty. -26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: empty. - - PCIe Slot9 af:00.xx: empty. - - PCIe Slot11 d8:00.xx: empty. -27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - - Quantity: 2. - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test. - - Main HW configuration: - - Chassis: SuperMicro SYS-741GE-TNRT. - - Motherboard: Super X13DEG-QT-P. - - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP. - - RAM Memory: 16* 32GB DDR5-4800. - - Disks: 2* 960GB SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot11 d8:00.xx: empty. -``` - -### Naming Convention - -Following naming convention is used within this page to specify physical -connectivity and wiring across defined CSIT testbeds: - -``` -- testbedname: testbedN. -- hostname: - - traffic-generator: tN-tgW. - - system-under-testX: tN-sutX. -- portnames: - - tN-tgW-cY/pZ. - - tN-sutX-cY/pZ. -- where: - - N - testbed number. - - tgW - server acts as traffic-generator with W index. - - sutX - server acts as system-under-test with X index. - - Y - PCIe slot number denoting a NIC card number within the host. - - Z - port number on the NIC card. -``` - -## Testbeds Configuration - -### Per Testbed Server Allocation and Naming - -#### 1-Node-Skylake Servers (1n-skx) PROD - -``` -- SUT [Server-Type-B6]: - - testbedname: testbed11. - - hostname: s1-t11-sut1. - - IPMI IP: 10.30.50.47 - - Host IP: 10.30.51.50 - - portnames: - - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -- SUT [Server-Type-B6]: - - testbedname: testbed12. - - hostname: s2-t12-sut1. - - IPMI IP: 10.30.50.48 - - Host IP: 10.30.51.51 - - portnames: - - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 1-Node-ThunderX2 Servers (1n-tx2) PROD - -``` -- SUT [Server-Type-E11]: - - testbedname: testbed13 - - hostname: s55-t13-sut1 - - IPMI IP: 10.30.50.70 - - Host IP: 10.30.51.70 - - portnames: - - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -- SUT [Server-Type-E11]: - - testbedname: testbed14 - - hostname: s56-t14-sut1 - - IPMI IP: 10.30.50.71 - - Host IP: 10.30.51.71 - - portnames: - - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -``` - -#### 1-Node-Cascadelake Servers (1n-clx) PROD - -``` -- SUT [Server-Type-C1]: - - testbedname: testbed11. - - hostname: s32-t14-sut1. - - IPMI IP: 10.30.55.17 - - Host IP: 10.32.8.17 - - portnames: - - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. - - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY - -``` -- SUT [Server-Type-B8]: - - testbedname: testbed25. - - hostname: s25-t25-sut1. - - IPMI IP: 10.30.50.58 - - Host IP: 10.30.51.61 - - portnames: - - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. -- TG [Server-Type-B7]: - - testbedname: testbed25. - - hostname: s26-t25-tg1. - - IPMI IP: 10.30.50.59 - - Host IP: 10.30.51.62 - - portnames: - - s26-t25-tg1-p1 - 10GE-port1. - - s26-t25-tg1-p2 - 10GE-port2. - - s26-t25-tg1-p3 - 10GE-port3. - - s26-t25-tg1-p4 - 10GE-port4. -``` - -#### 2-Node-Cascadelake Servers (2n-clx) PROD - -``` -- SUT [Server-Type-C2]: - - testbedname: testbed27. - - hostname: s33-t27-sut1. - - IPMI IP: 10.30.55.18 - - Host IP: 10.32.8.18 - - portnames: - - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-C3]: - - testbedname: testbed27. - - hostname: s34-t27-tg1. - - IPMI IP: 10.30.55.19 - - Host IP: 10.32.8.19 - - portnames: - - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- SUT [Server-Type-C2]: - - testbedname: testbed28. - - hostname: s35-t28-sut1. - - IPMI IP: 10.30.55.20 - - Host IP: 10.32.8.20 - - portnames: - - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-C3]: - - testbedname: testbed28. - - hostname: s36-t28-tg1. - - IPMI IP: 10.30.55.21 - - Host IP: 10.32.8.21 - - portnames: - - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- SUT [Server-Type-C2]: - - testbedname: testbed29. - - hostname: s37-t29-sut1. - - IPMI IP: 10.30.55.22 - - Host IP: 10.32.8.22 - - portnames: - - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. - - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. - - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-C3]: - - testbedname: testbed29. - - hostname: s38-t29-tg1. - - IPMI IP: 10.30.55.23 - - Host IP: 10.32.8.23 - - portnames: - - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. -``` - -#### 2-Node-Zen2 Servers (2n-zn2) PROD - -``` -- SUT [Server-Type-D1]: - - testbedname: testbed210. - - hostname: s60-t210-sut1. - - IPMI IP: 10.30.55.24 - - Host IP: 10.32.8.24 - - portnames: - - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. - - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. - - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. - - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. - - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. - - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. -- TG [Server-Type-D2]: - - testbedname: testbed210. - - hostname: s61-t210-tg1. - - IPMI IP: 10.30.55.25 - - Host IP: 10.32.8.25 - - portnames: - - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. - - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. - - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. -``` - -#### 2-Node-ThunderX2 Servers (2x-tx2) PROD - -Note: Server19 (TG) is shared between testbed33 & testbed211 - -``` -- SUT [Server-Type-E22]: - - testbedname: testbed211. - - hostname: s27-t211-sut1. - - IPMI IP: 10.30.50.69 - - Host IP: 10.30.51.69 - - portnames: - - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. -- TG [Server-Type-E31]: - - testbedname: testbed33 and testbed211. - - hostname: s19-t33t211-tg1. - - IPMI IP: 10.30.50.46 - - Host IP: 10.30.51.49 - - portnames: - - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 2-Node-Icelake Servers (2n-icx) PROD - -``` -- SUT [Server-Type-F1]: - - testbedname: testbed212. - - hostname: s71-t212-sut1. - - IPMI IP: 10.30.50.81 - - Host IP: 10.30.51.81 - - portnames: - - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed212. - - hostname: s72-t212-tg1. - - IPMI IP: 10.30.50.82 - - Host IP: 10.30.51.82 - - portnames: - - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-F1]: - - testbedname: testbed213. - - hostname: s83-t213-sut1. - - IPMI IP: 10.30.50.83 - - Host IP: 10.30.51.83 - - portnames: - - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed213. - - hostname: s84-t213-tg1. - - IPMI IP: 10.30.50.84 - - Host IP: 10.30.51.84 - - portnames: - - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-F1]: - - testbedname: testbed214. - - hostname: s85-t214-sut1. - - IPMI IP: 10.30.50.85 - - Host IP: 10.30.51.85 - - portnames: - - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed214. - - hostname: s86-t214-tg1. - - IPMI IP: 10.30.50.86 - - Host IP: 10.30.51.86 - - portnames: - - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-F1]: - - testbedname: testbed215. - - hostname: s87-t215-sut1. - - IPMI IP: 10.30.50.87 - - Host IP: 10.30.51.87 - - portnames: - - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- TG [Server-Type-F2]: - - testbedname: testbed215. - - hostname: s88-t215-tg1. - - IPMI IP: 10.30.50.88 - - Host IP: 10.30.51.88 - - portnames: - - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -#### 3-Node-Rangeley Servers (3n-rng) VERIFY - -Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - -``` -- ServerB22 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 - - Host IP: 10.30.51.9 - - portnames: - - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -- ServerB23 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 - - Host IP: 10.30.51.10 - - portnames: - - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -- ServerB24 [Server-Type-B5]: - - testbedname: testbed35. - - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 - - Host IP: 10.30.51.11 - - portnames: - - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. - - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. - - 1GB ports (tbd) -``` - -#### 3-Node-Taishan Servers (3n-tsh) PROD - -Note: Server19 (TG) is shared between testbed33 & testbed211 - -``` -- SUT [Server-Type-E21]: - - testbedname: testbed33. - - hostname: s17-t33-sut1. - - IPMI IP: 10.30.50.36 - - Host IP: 10.30.51.36 - - portnames: - - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE. - - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- SUT [Server-Type-E21]: - - testbedname: testbed33. - - hostname: s18-t33-sut2. - - IPMI IP: 10.30.50.37 - - Host IP: 10.30.51.37 - - portnames: - - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE. - - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- TG [Server-Type-E31]: - - testbedname: testbed33 and testbed211. - - hostname: s19-t33t211-tg1. - - IPMI IP: 10.30.50.46 - - Host IP: 10.30.51.49 - - portnames: - - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -``` - -#### 3-Node-Altra Servers (3n-alt) PROD - -``` -- SUT [Server-Type-E23]: - - testbedname: testbed34. - - hostname: s62-t34-sut1. - - IPMI IP: 10.30.50.72 - - Host IP: 10.30.51.72 - - portnames: - - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. -- SUT [Server-Type-E23]: - - testbedname: testbed34. - - hostname: s63-t34-sut2. - - IPMI IP: 10.30.50.73 - - Host IP: 10.30.51.73 - - portnames: - - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. -- TG [Server-Type-F4]: - - testbedname: testbed34. - - hostname: s64-t34-tg1. - - IPMI IP: 10.30.50.74 - - Host IP: 10.30.51.74 - - portnames: - - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -#### 3-Node-Icelake Servers (3n-icx) PROD - -``` -- ServerF1 [Server-Type-F1]: - - testbedname: testbed37. - - hostname: s65-t37-sut1. - - IPMI IP: 10.30.50.75 - - Host IP: 10.30.51.75 - - portnames: - - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: - - testbedname: testbed37. - - hostname: s66-t37-sut2. - - IPMI IP: 10.30.50.76 - - Host IP: 10.30.51.76 - - portnames: - - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF3 [Server-Type-F3]: - - testbedname: testbed37. - - hostname: s67-t37-tg1. - - IPMI IP: 10.30.50.77 - - Host IP: 10.30.51.77 - - portnames: - - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: - - testbedname: testbed38. - - hostname: s78-t38-sut1. - - IPMI IP: 10.30.50.78 - - Host IP: 10.30.51.78 - - portnames: - - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: - - testbedname: testbed38. - - hostname: s79-t38-sut2. - - IPMI IP: 10.30.50.79 - - Host IP: 10.30.51.79 - - portnames: - - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF3 [Server-Type-F3]: - - testbedname: testbed38. - - hostname: s80-t38-tg1. - - IPMI IP: 10.30.50.80 - - Host IP: 10.30.51.80 - - portnames: - - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -#### 3-Node-SnowRidge Servers (3n-snr) PROD - -``` -- ServerG1 [Server-Type-G1]: - - testbedname: testbed39. - - hostname: s93-t39-sut1. - - IPMI IP: 10.30.50.93 - - Host IP: 10.30.51.93 - - portnames: - - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE. - - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE. -- ServerG1 [Server-Type-G1]: - - testbedname: testbed39. - - hostname: s94-t39-sut2. - - IPMI IP: 10.30.50.94 - - Host IP: 10.30.51.94 - - portnames: - - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- ServerF4 [Server-Type-F4]: - - testbedname: testbed39. - - hostname: s89-t39t310-tg1. - - IPMI IP: 10.30.50.89 - - Host IP: 10.30.51.89 - - portnames: - - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -``` - -#### 2-Node-SapphireRapids Servers (2n-spr) PROD - -``` -- SUT [Server-Type-H1]: - - testbedname: testbed21. - - hostname: s52-t21-sut1. - - IPMI IP: 10.30.50.52 - - Host IP: 10.30.51.52 - - portnames: - - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. - - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE. - - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE. -- TG [Server-Type-H2]: - - testbedname: testbed21. - - hostname: s53-t21-tg1. - - IPMI IP: 10.30.50.53 - - Host IP: 10.30.51.53 - - portnames: - - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. - - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. -- SUT [Server-Type-H3]: - - testbedname: testbed22. - - hostname: s54-t22-sut1. - - IPMI IP: 10.30.50.54 - - Host IP: 10.30.51.54 - - portnames: - - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- TG [Server-Type-H4]: - - testbedname: testbed22. - - hostname: s55-t22-tg1. - - IPMI IP: 10.30.50.55 - - Host IP: 10.30.51.55 - - portnames: - - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- SUT [Server-Type-H5]: - - testbedname: testbed23. - - hostname: s56-t23-sut1. - - IPMI IP: 10.30.50.56 - - Host IP: 10.30.51.56 - - portnames: - - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- TG [Server-Type-H6]: - - testbedname: testbed23. - - hostname: s57-t23-tg1. - - IPMI IP: 10.30.50.57 - - Host IP: 10.30.51.57 - - portnames: - - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- SUT [Server-Type-H5]: - - testbedname: testbed24. - - hostname: s58-t24-sut1. - - IPMI IP: 10.30.50.58 - - Host IP: 10.30.51.58 - - portnames: - - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- TG [Server-Type-H6]: - - testbedname: testbed24. - - hostname: s59-t24-tg1. - - IPMI IP: 10.30.50.59 - - Host IP: 10.30.51.59 - - portnames: - - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. - - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. - - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. - - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -``` - -### Per Testbed Wiring - -#### 1-Node-Skylake Wiring (1n-skx) PROD - -``` -- testbed11: - - ring1 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. - - ring2 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. - - ring3 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - - ring4 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4. - - ring5 100GE-ports e810-2p100GE: - - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1. - - ring6 100GE-ports e810-2p100GE: - - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2. -- testbed12: - - ring1 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. - - ring2 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. - - ring3 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. - - ring4 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4. - - ring5 100GE-ports e810-2p100GE: - - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1. - - ring6 100GE-ports e810-2p100GE: - - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. -``` - -#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD - -``` -- testbed13: - - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. - - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. - - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. - -- testbed14: - - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. - - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. - - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. - - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. -``` - -#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY - -``` -- testbed25: - - link1 10GE-port x710-4p10GE on SUT: - - t25-tg1-p1 to t25-sut1-c2/p1. - - link2 10GE-port x710-4p10GE on SUT: - - t25-tg1-p2 to t25-sut1-c2/p2. - - link3 10GE-port x710-4p10GE on SUT: - - t25-tg1-p3 to t25-sut1-c2/p3. - - link4 10GE-port x710-4p10GE on SUT: - - t25-tg1-p4 to t25-sut1-c2/p4. -``` - -#### 2-Node-Cascadelake Wiring (2n-clx) PROD - -``` -- testbed27: - - ring1 10GE-ports x710-4p10GE on SUT: - - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. - - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. - - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. - - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. - - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. - - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. - - ring6 100GE-ports e810-2p100GE on TG: - - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. - - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. -- testbed28: - - ring1 10GE-ports x710-4p10GE on SUT: - - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. - - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. - - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. - - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. - - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. - - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. - - ring6 100GE-ports e810-2p100GE on TG: - - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. - - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. -- testbed29: - - ring1 10GE-ports x710-4p10GE on SUT: - - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. - - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. - - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. - - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. - - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. - - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: - - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. - - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. -``` - -#### 2-Node-Zen2 Wiring (2n-zn2) PROD - -``` -- testbed210: - - ring1 10GE-ports x710-4p10GE on SUT: - - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. - - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. - - ring2 10GE-ports x710-4p10GE on SUT: - - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. - - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. - - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. - - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. - - ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. - - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. -``` - -#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD - -``` -- testbed211: - - ring1 10GE-ports x520-2p10GE on SUTs: - - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. - - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. -``` - -#### 2-Node-Icelake Wiring (2n-icx) PROD - -``` -- testbed212: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. - - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. - - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. - - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. - - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. - - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. - - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. -- testbed213: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1. - - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1. - - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2. - - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3. - - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1. - - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. - - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. -- testbed214: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1. - - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1. - - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2. - - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3. - - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1. - - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. - - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. -- testbed215: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT - - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1. - - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: - - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1. - - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2. - - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3. - - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1. - - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: - - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. - - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. -``` - -#### 3-Node-Rangeley Wiring (3n-rng) VERIFY - -``` -To be completed. -``` - -#### 3-Node-Taishan Wiring (3n-tsh) PROD - -``` -- testbed33: - - ring1 10GE-ports x520-2p10GE on SUTs: - - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. - - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. - - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. - - ring2 25GE-ports cx4-2p25GE on SUTs: - - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. - - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. - - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. -``` - -#### 3-Node-Altra Wiring (3n-alt) PROD - -``` -- testbed34: - - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: - - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. - - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. - - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. -``` - -#### 3-Node-Icelake Wiring (3n-icx) PROD - -``` -- testbed37: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: - - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. - - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. - - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: - - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. - - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. - - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. - - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. - - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. - - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT - - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. - - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. -- testbed38: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: - - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. - - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2. - - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: - - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1. - - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2. - - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2. - - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3. - - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4. - - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT - - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. - - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. -``` - -#### 3-Node-SnowRidge Wiring (3n-snr) PROD - -``` -- testbed39: - - ring1 25GE-ports e810-XXVDA4-4p25GE: - - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. - - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. - - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. - - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3. - - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4. - - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. -``` - -#### 2-Node-SapphireRapids Wiring (2n-spr) PROD - -``` -- testbed21: - - ring1 200GE-ports ConnectX7-2p200GE: - - ?? - - ?? - - ?? -- testbed22: - - ring1 100GE-ports e810-2CQDA2-2p100GE: - - s53-t21-tg1-c2/p1 to s54-t22-sut1-c2/p2. - - s54-t22-sut1-c2/p1 to s54-t22-sut1-c7/p2. - - s54-t22-sut1-c7/p1 to s55-t22-tg1-c2/p2. -- testbed23: - - ring1 200GE-ports ConnectX7-2p200GE: - - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1. - - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2. - - ring2 100GE-ports e810-2CQDA2-2p100GE: - - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1. - - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2. - - ring3 25GE-ports e810-XXVDA4-2p25GE: - - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1. - - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2. - - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3. - - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4. - - ring4 200GE-ports ConnectX7-2p200GE: - - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2. - - ring5 100GE-ports e810-2CQDA2-2p100GE: - - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2. -- testbed24: - - ring1 200GE-ports ConnectX7-2p200GE: - - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1. - - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2. - - ring2 100GE-ports e810-2CQDA2-2p100GE: - - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1. - - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2. - - ring3 25GE-ports e810-XXVDA4-2p25GE: - - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1. - - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2. - - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3. - - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4. - - ring4 200GE-ports ConnectX7-2p200GE: - - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2. - - ring5 100GE-ports e810-2CQDA2-2p100GE: - - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2. -``` \ No newline at end of file