X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=d636a691dcca162b85c2f3a75697584b6a821997;hb=refs%2Fchanges%2F33%2F29033%2F2;hp=8599746159f78194c22f3a7d52bde9fc63e3c3b6;hpb=ccbc47e0405c7b2e671fa5c8d9200394fde37099;p=csit.git diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 8599746159..d636a691dc 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -10,6 +10,7 @@ 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) + 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) @@ -27,11 +28,12 @@ 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip) - 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup) + 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod) 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup) + 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup]) 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod) 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) @@ -44,7 +46,8 @@ 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod) 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) - 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup) + 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) + 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup]) 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod) 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo) @@ -68,22 +71,23 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb - 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 - 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 - 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0 - 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 - 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 - 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 - 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 - 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 - 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 -10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 -11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 -12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 -13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 -14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 - Totals: 22 35 18 12 19 1 2 3 1 2 2 + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb #clx #zn2 + 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 + 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 + 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 + 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 + 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 + 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 + 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0 0 +10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 +11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 +12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 0 0 +13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 0 0 +14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 +15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 + Totals: 22 35 18 12 19 1 2 3 1 2 2 7 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -133,6 +137,13 @@ one TG (Server-Type-C3) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. +### 2-Node-Zen2 EPYC AMD (2n-zn2) + +Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and +one TG (Server-Type-D2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Haswell Xeon Intel (3n-hsw) Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one @@ -234,11 +245,21 @@ Name | Comment 10.30.50.24 | t3-tg1 10.30.50.25 | t3-sut1 10.30.50.26 | t3-sut-2 -10.30.50.28 | t4-sut1 -10.30.50.29 | t4-sut2 -10.30.50.30 | t4-sut3 +10.30.50.28 | s41-nomad +10.30.50.29 | s39-nomad +10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0 +10.30.50.30 | s40-nomad +10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1 +10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2 +10.30.50.32 | s42-nomad (formerly nomad1) +10.30.50.33 | s43-nomad (formerly nomad2) +10.30.50.34 | s44-nomad (formerly nomad3) +10.30.50.35 | s45-nomad (formerly nomad4) 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 +10.30.50.38 | fdio-marvell-dev +10.30.50.39 | s53-nomad +10.30.50.40 | s54-nomad 10.30.50.41 | s3-t21-sut1 10.30.50.42 | s4-t21-tg1 10.30.50.43 | s11-t31-sut1 @@ -258,24 +279,33 @@ Name | Comment 10.30.50.57 | s16-t32-tg1 10.30.50.58 | s25-t25-sut1 10.30.50.59 | s26-t25-tg1 +10.30.50.65 | s52-nomad +10.30.50.66 | s51-nomad (out of order) +10.30.50.67 | s49-nomad +10.30.50.68 | s50-nomad (out of order) 10.30.50.69 | s27-t13-sut +10.30.50.255 | Broadcast n/a | s20-t34-sut1 n/a | s21-t34-sut2 -10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0 -10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1 -10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2 +10.30.55.0 | network +10.30.55.1 | Router 10.30.55.10 | s28-t26t35-tg1 10.30.55.11 | s29-t26-sut1 10.30.55.12 | s30-t35-sut1 10.30.55.13 | s31-t35-sut2 -10.30.50.255 | Broadcast -x.x.x.x | s32-t14-sut1 -x.x.x.x | s33-t27-sut1 -x.x.x.x | s34-t27-tg1 -x.x.x.x | s35-t28-sut1 -x.x.x.x | s36-t28-tg1 -x.x.x.x | s37-t29-sut1 -x.x.x.x | s38-t29-tg1 +10.30.55.14 | s46-nomad (formerly server-type-c4-1) +10.30.55.15 | s47-nomad (formerly server-type-c4-2) +10.30.55.16 | s48-nomad (formerly server-type-c4-3) +10.30.55.17 | s32-t14-sut1 +10.30.55.18 | s33-t27-sut1 +10.30.55.19 | s34-t27-tg1 +10.30.55.20 | s35-t28-sut1 +10.30.55.21 | s36-t28-tg1 +10.30.55.22 | s37-t29-sut1 +10.30.55.23 | s38-t29-tg1 +10.30.55.24 | s60-t210-sut1 +10.30.55.25 | s61-t210-tg1 +10.30.55.255 | Broadcast ### Management VLAN IP Addresses @@ -306,14 +336,18 @@ Name | Comment 10.30.51.24 | t3-tg1 10.30.51.25 | t3-sut1 10.30.51.26 | t3-sut-2 -10.30.51.28 | t4-sut1 -10.30.51.29 | t4-sut2 -10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED -10.30.51.30 | t4-sut3 -10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED -10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED +10.30.51.28 | s41-nomad +10.30.51.29 | s39-nomad +10.30.51.30 | s40-nomad +10.30.51.32 | s42-nomad (formerly nomad1) +10.30.51.33 | s43-nomad (formerly nomad2) +10.30.51.34 | s44-nomad (formerly nomad3) +10.30.51.35 | s45-nomad (formerly nomad4) 10.30.51.36 | s17-t33-sut1 10.30.51.37 | s18-t33-sut2 +10.30.51.38 | fdio-marvell-dev +10.30.51.39 | s53-nomad +10.30.51.40 | s54-nomad 10.30.51.41 | s20-t34-sut1 10.30.51.42 | s21-t34-sut2 10.30.51.44 | s3-t21-sut1 @@ -335,22 +369,34 @@ Name | Comment 10.30.51.60 | s16-t32-tg1 10.30.51.61 | s25-t25-sut1 10.30.51.62 | s26-t25-tg1 +10.30.51.65 | s52-nomad +10.30.51.66 | s51-nomad +10.30.51.67 | s49-nomad +10.30.51.68 | s50-nomad 10.30.51.69 | s27-t13-sut1 -10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED -10.30.51.106-10.30.51.180 | VIRL2 -10.30.51.181-10.30.51.254 | VIRL3 +10.30.51.70-10.30.51.105 | FREE +10.30.51.106-10.30.51.180 | FREE +10.30.51.181-10.30.51.254 | FREE 10.30.51.255 | Broadcast +10.32.8.0 | network +10.32.8.1 | Router 10.32.8.10 | s28-t26t35-tg1 10.32.8.11 | s29-t26-sut1 10.32.8.12 | s30-t35-sut1 10.32.8.13 | s31-t35-sut2 -x.x.x.x | s32-t14-sut1 -x.x.x.x | s33-t27-sut1 -x.x.x.x | s34-t27-tg1 -x.x.x.x | s35-t28-sut1 -x.x.x.x | s36-t28-tg1 -x.x.x.x | s37-t29-sut1 -x.x.x.x | s38-t29-tg1 +10.32.8.14 | s46-nomad (formerly server-type-c4-1) +10.32.8.15 | s47-nomad (formerly server-type-c4-2) +10.32.8.16 | s48-nomad (formerly server-type-c4-3) +10.32.8.17 | s32-t14-sut1 +10.32.8.18 | s33-t27-sut1 +10.32.8.19 | s34-t27-tg1 +10.32.8.20 | s35-t28-sut1 +10.32.8.21 | s36-t28-tg1 +10.32.8.22 | s37-t29-sut1 +10.32.8.23 | s38-t29-tg1 +10.32.8.24 | s60-t210-sut1 +10.32.8.25 | s61-t210-tg1 +10.32.8.255 | Broadcast ## Server Specifications @@ -582,7 +628,6 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports - 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 1. - Physical connectivity: @@ -603,7 +648,6 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. - 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: @@ -620,7 +664,6 @@ FD.io CSIT lab contains following server types: - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. @@ -641,12 +684,10 @@ FD.io CSIT lab contains following server types: - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. - - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. - 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: @@ -663,6 +704,36 @@ FD.io CSIT lab contains following server types: - no cards. - Numa1: - no cards. +15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: x710-4p10GE Intel. + - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. +16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot2 41:00.xx: x710-4p10GE Intel. + - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. ``` ### Naming Convention @@ -740,14 +811,14 @@ connectivity and wiring across defined CSIT testbeds: - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. ``` -#### 1-Node-Cascadelake Servers (1n-clx) SETUP +#### 1-Node-Cascadelake Servers (1n-clx) PROD ``` - SUT [Server-Type-C1]: - testbedname: testbed11. - hostname: s32-t14-sut1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.17 + - Host IP: 10.32.8.17 - portnames: - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -926,8 +997,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - SUT [Server-Type-C2]: - testbedname: testbed27. - hostname: s33-t27-sut1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.18 + - Host IP: 10.32.8.18 - portnames: - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -940,8 +1011,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - TG [Server-Type-C3]: - testbedname: testbed27. - hostname: s34-t27-tg1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.19 + - Host IP: 10.32.8.19 - portnames: - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -954,8 +1025,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - SUT [Server-Type-C2]: - testbedname: testbed28. - hostname: s35-t28-sut1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.20 + - Host IP: 10.32.8.20 - portnames: - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -968,8 +1039,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - TG [Server-Type-C3]: - testbedname: testbed28. - hostname: s36-t28-tg1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.21 + - Host IP: 10.32.8.21 - portnames: - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -982,8 +1053,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - SUT [Server-Type-C2]: - testbedname: testbed29. - hostname: s37-t29-sut1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.22 + - Host IP: 10.32.8.22 - portnames: - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -996,8 +1067,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - TG [Server-Type-C3]: - testbedname: testbed29. - hostname: s38-t29-tg1. - - IPMI IP: x.x.x.x - - Host IP: x.x.x.x + - IPMI IP: 10.30.55.23 + - Host IP: 10.32.8.23 - portnames: - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. @@ -1009,6 +1080,39 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` +#### 2-Node-Zen2 Servers (2n-zn2) SETUP + +``` +- SUT [Server-Type-D1]: + - testbedname: testbed210. + - hostname: s60-t210-sut1. + - IPMI IP: 10.30.55.24 + - Host IP: 10.32.8.24 + - portnames: + - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. + - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. + - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. + - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. + - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. + - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-D2]: + - testbedname: testbed210. + - hostname: s61-t210-tg1. + - IPMI IP: 10.30.55.25 + - Host IP: 10.32.8.25 + - portnames: + - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. + - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. + - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. +``` + #### 3-Node-Haswell Servers (3n-hsw) PROD ``` @@ -1499,7 +1603,7 @@ To be completed. - t25-tg1-p4 to t25-sut1-c2/p4. ``` -#### 2-Node-Cascadelake Wiring (2n-clx) SETUP +#### 2-Node-Cascadelake Wiring (2n-clx) PROD ``` - testbed27: @@ -1543,6 +1647,24 @@ To be completed. - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. ``` +#### 2-Node-Zen2 Wiring (2n-zen2) SETUP + +``` +- testbed210: + - ring1 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. + - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. + - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. + - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. + - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. +``` + #### 3-Node-Haswell Wiring (3n-hsw) PROD ```