X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Freport%2Fintroduction%2Fmethodology_plrsearch.rst;h=65ac59022277385ab36b4dfc2bd8c401a903328d;hb=c123e1590b7de379db10124c9d6d32bd2e20e848;hp=ae0b356d0fc86934c7ae3529cc86b713041c47d9;hpb=d7ad663e1368044edb37fa446dc8dc669a3b02cf;p=csit.git diff --git a/docs/report/introduction/methodology_plrsearch.rst b/docs/report/introduction/methodology_plrsearch.rst index ae0b356d0f..65ac590222 100644 --- a/docs/report/introduction/methodology_plrsearch.rst +++ b/docs/report/introduction/methodology_plrsearch.rst @@ -1,4 +1,4 @@ -.. _plrsearch_algorithm: +.. _`PLRsearch algorithm`: PLRsearch ^^^^^^^^^ @@ -338,12 +338,50 @@ as the observed trends have varied characteristics. Probably, using a more realistic fitting functions will give better estimates than trend analysis. -Graphical example -````````````````` +Graphical examples +`````````````````` + +The following pictures show the upper and lower bound (one sigma) +on estimated critical rate, as computed by PLRsearch, after each trial measurement +within the 30 minute duration of a test run. + +Both graphs are focusing on later estimates. Estimates computed from +few initial measurements are wildly off the y-axis range shown. + +L2 patch +-------- + +This test case shows quite narrow critical region. Both fitting functions +give similar estimates, the graph shows the randomness of measurements, +and a trend. Both fitting functions seem to be somewhat overestimating +the critical rate. The final estimated interval is too narrow, +a longer run would report estimates somewhat bellow the current lower bound. + +.. only:: latex + + .. raw:: latex + + \begin{figure}[H] + \centering + \graphicspath{{../_tmp/src/introduction/}} + \includegraphics[width=0.90\textwidth]{PLR_patch} + \label{fig:PLR_patch} + \end{figure} + +.. only:: html + + .. figure:: PLR_patch.svg + :alt: PLR_patch + :align: center + +Vhost +----- -The following picture shows the estimated average of the critical rate -computed by the two fitting functions after each trial measurement -within the 30 minute duration of a PLRsearch test run. +This test case shows quite broad critical region. Fitting functions give +fairly differing estimates. One overestimates, the other underestimates. +The graph mostly shows later measurements slowly bringing the estimates +towards each other. The final estimated interval is too broad, +a longer run would return a smaller interval within the current one. .. only:: latex @@ -352,14 +390,14 @@ within the 30 minute duration of a PLRsearch test run. \begin{figure}[H] \centering \graphicspath{{../_tmp/src/introduction/}} - \includegraphics[width=0.90\textwidth]{PLRsearch} - \label{fig:PLRsearch} + \includegraphics[width=0.90\textwidth]{PLR_vhost} + \label{fig:PLR_vhost} \end{figure} .. only:: html - .. figure:: PLRsearch.svg - :alt: PLRsearch + .. figure:: PLR_vhost.svg + :alt: PLR_vhost :align: center .. _plrsearch draft: https://tools.ietf.org/html/draft-vpolak-bmwg-plrsearch-00