X-Git-Url: https://gerrit.fd.io/r/gitweb?a=blobdiff_plain;f=docs%2Freport%2Fvpp_device_tests%2Foverview.rst;h=fb9f68374ae1662280a73d65145ff98a9080fd35;hb=6ebf54b7c0471d2723066e051307bff5561f63d1;hp=25bfecd9e531b4e00c36715c9a8c701e276681ba;hpb=455dd6483d66705ce78e60ce6ee22c73db80230b;p=csit.git diff --git a/docs/report/vpp_device_tests/overview.rst b/docs/report/vpp_device_tests/overview.rst index 25bfecd9e5..fb9f68374a 100644 --- a/docs/report/vpp_device_tests/overview.rst +++ b/docs/report/vpp_device_tests/overview.rst @@ -7,11 +7,12 @@ Virtual Topologies CSIT VPP Device tests are executed in Physical containerized topologies created on demand using set of scripts hosted and developed under CSIT repository. It runs on physical baremetal servers hosted by LF FD.io project. -Based on the packet path thru SUT Containers, two distinct logical topology +Based on the packet path thru SUT Containers, three distinct logical topology types are used for VPP DUT data plane testing: #. vfNIC-to-vfNIC switching topologies. -#. Nested-VM service switching topologies. (Planned to be added in rls1901) +#. vfNIC-to-vhost-user switching topologies. +#. vfNIC-to-memif switching topologies. vfNIC-to-vfNIC Switching ~~~~~~~~~~~~~~~~~~~~~~~~ @@ -50,18 +51,100 @@ upon completion of all functional tests. Each node is a container running on physical server. During the test execution, all nodes are reachable thru the Management (not shown above for clarity). +vfNIC-to-vhost-user Switching +~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ + +vfNIC-to-vhost-user switching topology test cases require VPP DUT to communicate +with Virtual Machine (VM) over Vhost-user virtual interfaces. VM is created on +SUT1 for the duration of these particular test cases only. Virtual test topology +with VM is shown in the figure below. + +.. only:: latex + + .. raw:: latex + + \begin{figure}[H] + \centering + \graphicspath{{../_tmp/src/vpp_device_tests/}} + \includegraphics[width=0.90\textwidth]{vf-2n-nic2vhost} + \label{fig:vf-2n-nic2vhost} + \end{figure} + +.. only:: html + + .. figure:: ../vpp_device_tests/vf-2n-nic2vhost.svg + :alt: vf-2n-nic2vhost + :align: center + +vfNIC-to-memif Switching +~~~~~~~~~~~~~~~~~~~~~~~~ + +vfNIC-to-memif switching topology test cases require VPP DUT to communicate +with another Docker Container over memif interfaces. Container is created for +the duration of these particular test cases only and it is running the same VPP +version as running on DUT. Virtual test topology with Memif is shown in +the figure below. + +.. only:: latex + + .. raw:: latex + + \begin{figure}[H] + \centering + \graphicspath{{../_tmp/src/vpp_device_tests/}} + \includegraphics[width=0.90\textwidth]{vf-2n-nic2memif} + \label{fig:vf-2n-nic2memif} + \end{figure} + +.. only:: html + + .. figure:: ../vpp_device_tests/vf-2n-nic2memif.svg + :alt: vf-2n-nic2memif + :align: center + Functional Tests Coverage ------------------------- -|csit-release| includes following VPP functionality tested in virtual VM +|csit-release| includes following VPP functionality tested in VPP Device environment: +-----------------------+----------------------------------------------+ | Functionality | Description | +=======================+==============================================+ -| IPv4 | ICMPv4. | +| ACL | Ingress Access Control List security for L2 | +| | Bridge-Domain MAC switching, IPv4 routing, | +| | IPv6 routing. | ++-----------------------+----------------------------------------------+ +| COP | COP address white-list and black-list | +| | filtering for IPv4 and IPv6 routing. | ++-----------------------+----------------------------------------------+ +| IPSec | IPSec tunnel and transport modes. | ++-----------------------+----------------------------------------------+ +| IPv4 | IPv4 routing, ICMPv4. | ++-----------------------+----------------------------------------------+ +| IPv6 | IPv4 routing, ICMPv6. | ++-----------------------+----------------------------------------------+ +| L2BD | L2 Bridge-Domain switching for untagged | +| | Ethernet. | ++-----------------------+----------------------------------------------+ +| L2XC | L2 Cross-Connect switching for untagged | +| | Ethernet. | ++-----------------------+----------------------------------------------+ +| Memif Interface | Baseline VPP memif interface tests. | ++-----------------------+----------------------------------------------+ +| QoS Policer Metering | Ingress packet rate metering and marking for | +| | IPv4, IPv6. | ++-----------------------+----------------------------------------------+ +| SRv6 | Segment routing over IPv6, base and proxy. | ++-----------------------+----------------------------------------------+ +| Tap Interface | Baseline Linux tap interface tests. | ++-----------------------+----------------------------------------------+ +| VLAN Tag | L2 VLAN subinterfaces. | ++-----------------------+----------------------------------------------+ +| Vhost-user Interface | Baseline VPP vhost-user interface tests. | +-----------------------+----------------------------------------------+ -| IPv6 | ICMPv6. | +| VXLAN | VXLAN overlay tunneling for L2-over-IPv4 and | +| | -over-IPv6. | +-----------------------+----------------------------------------------+ Tests Naming