Change-Id: I3e80997ace8073edc90f662f6393bd62005fc815
Signed-off-by: Peter Mikus <pmikus@cisco.com>
tests, performance changes, environment or methodology changes, known CSIT
issues; *Packet Throughput Graphs* and *Packet Latency
Graphs* - plotted NDR, PDR throughput and latency results from multiple
tests, performance changes, environment or methodology changes, known CSIT
issues; *Packet Throughput Graphs* and *Packet Latency
Graphs* - plotted NDR, PDR throughput and latency results from multiple
- test job executions; *Test Environment* - environment description;
- *Documentation* - CSIT source code documentation for VPP performance tests.
+ test job executions; *Throughput Speedup Multi-Core* - plotted core
+ configuration speedup comparision; *Test Environment* - environment
+ description; *VPP HTTP Server Performance Results* - plotted HTTP Server
+ performance; *Documentation* - CSIT source code documentation for VPP
+ performance tests.
#. **DPDK Performance Tests** - DPDK performance tests executed in
physical FD.io testbeds; *Overview* - tested topologies, test coverage;
#. **DPDK Performance Tests** - DPDK performance tests executed in
physical FD.io testbeds; *Overview* - tested topologies, test coverage;
*Test Environment* - environment description ;
*Documentation* - source code documentation for Honeycomb functional tests.
*Test Environment* - environment description ;
*Documentation* - source code documentation for Honeycomb functional tests.
-#. **VPP Unit Tests** - refers to VPP functional unit tests executed as
- part of vpp make test verify option within the FD.io VPP project; listed in
- this report to give a more complete view about executed VPP functional tests;
- *Overview* - short overview of unit test framework and executed tests;
- *Documentation* - source code documentation of VPP unit tests.
-
#. **NSH_SFC Functional Tests** - NSH_SFC functional tests executed in
virtual FD.io testbeds; *Overview* - tested virtual topologies, test
coverage and naming specifics; *CSIT Release Notes* - changes in CSIT
#. **NSH_SFC Functional Tests** - NSH_SFC functional tests executed in
virtual FD.io testbeds; *Overview* - tested virtual topologies, test
coverage and naming specifics; *CSIT Release Notes* - changes in CSIT
Known Issues\r
------------\r
\r
Known Issues\r
------------\r
\r
-<to be updated before rls1804 release>\r
-\r
Here is the list of known issues in CSIT |release| for VPP performance tests:\r
\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
| # | Issue | Jira ID | Description |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
Here is the list of known issues in CSIT |release| for VPP performance tests:\r
\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
| # | Issue | Jira ID | Description |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 1 | Vic1385 and Vic1227 low performance. | VPP-664 | Low NDR performance. |\r
-| | | | |\r
-+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 2 | Sporadic (1 in 200) NDR discovery test failures | CSIT-570 | DPDK reporting rx-errors, indicating L1 issue. Suspected issue |\r
+| 1 | Sporadic (1 in 200) NDR discovery test failures | CSIT-570 | DPDK reporting rx-errors, indicating L1 issue. Suspected issue |\r
| | on x520. | | with HW combination of X710-X520 in LF testbeds. Not observed |\r
| | | | outside of LF testbeds. |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
| | on x520. | | with HW combination of X710-X520 in LF testbeds. Not observed |\r
| | | | outside of LF testbeds. |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 3 | Lower than expected NDR throughput with | CSIT-571 | Suspected NIC firmware or DPDK driver issue affecting NDR and |\r
-| | xl710 and x710 NICs, compared to x520 NICs. | | PDR throughput. Applies to XL710 and X710 NICs. |\r
+| 2 | Lower than expected NDR throughput of DPDK | CSIT-571 | Suspected NIC firmware or DPDK driver issue affecting NDR and |\r
+| | testpmd and VPP L2 path NDR throughput with | | PDR throughput on XL710 and X710 NICs. |\r
+| | xl710 and x710 NICs, compared to x520 NICs. | | |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 4 | rls1801 plugin related performance regression | CSIT-925 | With all plugins loaded NDR, PDR and MaxRates vary |\r
-| | | | intermittently from 3% to 5% across multiple test executions. |\r
-| | | | Requires plugin code bisecting. |\r
+| 3 | Tagged Ethernet dot1q and dot1ad L2 path | CSIT-1066 | Tagged Ethernet dot1q and dot1ad L2 path throughput regression: |\r
+| | throughput regression. | | NDR -2%..-5%, PDR -2%..-6%, MRR. Affects l2xc and l2bd |\r
+| | | | performance tests. |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 5 | rls1801 generic small performance regression | CSIT-926 | Generic performance regression of discovered NDR, PDR and |\r
-| | ip4base, l2xcbase, l2bdbase | | MaxRates of -3%..-1% vs. rls1710, affects ip4base, l2xcbase, |\r
-| | | | l2bdbase test suites. Not detected by CSIT performance trending |\r
-| | | | scheme as it was masked out by another issue CSIT-925. |\r
+| 4 | IPSec (software, no QAT HW) throughput | CSIT-1064 | IPSec throughput regression: NDR -3%..-8%, PDR -2%..-8%, MRR |\r
+| | regression. | | -3%..-7%. |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
-| 6 | rls1801 substantial NDR/PDR regression for | CSIT-928 | NDR regression of -7%..-15%, PDR regression of -3%..-15% |\r
-| | IPSec tunnel scale with HW QAT crypto-dev | | compared to rls1710. |\r
+| 5 | High failure rate of creating working container | CSIT-1065 | Orchestrated container topology tests failing data plane |\r
+| | topologies with K8s/Ligato orchestration. | | verification indicating configuration issue. Suspected issue |\r
+| | | | with Ligato vpp-agent. |\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r
+---+-------------------------------------------------+------------+-----------------------------------------------------------------+\r