Infra: Ansible Nomad
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30       1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0
74  3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0
75  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0
76  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
77  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
78  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
79  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0
80  9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
84 13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
85 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0
86                                  Totals: 22   35   18   12   19    1    2    3    1    2    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
137
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
144
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
148
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
150
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 3-Node-MACCHIATObin Arm Marvell
157
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163 ### 3-Node-Rangeley Atom Testbeds
164
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ## Server Management
171
172 ### Requirements
173
174 For management purposes, each server must have following two ports
175 connected to the management network:
176
177 ```
178 - 1GE IPMI port
179   - IPMI - Intelligent Platform Management Interface.
180   - Required for access to embedded server management with WebUI, CLI,
181     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183   - hostOS management port for general system management.
184 ```
185
186 ### Addressing
187
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
190
191 ```
192 1. LOM (IPMI) VLAN:
193     - Subnet: 10.30.50.0/24
194     - Gateway: 10.30.50.1
195     - Broadcast: 10.30.50.255
196     - DNS1: 199.204.44.24
197     - DNS2: 199.204.47.54
198 2. Management Vlan:
199     - Subnet: 10.30.51.0/24
200     - Gateway: 10.30.51.1
201     - Broadcast: 10.30.51.255
202     - DNS1: 199.204.44.24
203     - DNS2: 199.204.47.54
204 ```
205
206 To access these hosts, VPN connection is required.
207
208 ### LOM (IPMI) VLAN IP Addresses
209
210 Name         | Comment
211 ------------ | -------
212 10.30.50.0   | network
213 10.30.51.1   | Router
214 10.30.50.2   | LF Reserved
215 10.30.50.3   | LF Reserved
216 10.30.50.4   | LF Reserved
217 10.30.50.5   | LF Reserved
218 10.30.50.6   | LF Reserved
219 10.30.50.7   | LF Reserved
220 10.30.50.8   | LF Reserved
221 10.30.50.9   | LF Reserved
222 10.30.50.10  | LF Reserved
223 10.30.50.11  | LF Reserved
224 10.30.50.12  | LF Reserved
225 10.30.50.13  | LF Reserved
226 10.30.50.14  | LF Reserved
227 10.30.50.15  | LF Reserved
228 10.30.50.16  | t1-tg1
229 10.30.50.17  | t1-sut1
230 10.30.50.18  | t1-sut2
231 10.30.50.20  | t2-tg1
232 10.30.50.21  | t2-sut1
233 10.30.50.22  | t2-sut2
234 10.30.50.24  | t3-tg1
235 10.30.50.25  | t3-sut1
236 10.30.50.26  | t3-sut-2
237 10.30.50.28  | t4-sut1
238 10.30.50.29  | s39-nomad
239 10.30.50.30  | t4-sut3
240 10.30.50.36  | s17-t33-sut1
241 10.30.50.37  | s18-t33-sut2
242 10.30.50.41  | s3-t21-sut1
243 10.30.50.42  | s4-t21-tg1
244 10.30.50.43  | s11-t31-sut1
245 10.30.50.44  | s12-t31-sut2
246 10.30.50.45  | s13-t31-tg1
247 10.30.50.46  | s19-t33t34-tg1
248 10.30.50.47  | s1-t11-sut1
249 10.30.50.48  | s2-t12-sut1
250 10.30.50.49  | s5-t22-sut1
251 10.30.50.50  | s6-t22-tg1
252 10.30.50.51  | s7-t23-sut1
253 10.30.50.52  | s8-t23-tg1
254 10.30.50.53  | s9-t24-sut1
255 10.30.50.54  | s10-t24-tg1
256 10.30.50.55  | s14-t32-sut1
257 10.30.50.56  | s15-t32-sut2
258 10.30.50.57  | s16-t32-tg1
259 10.30.50.58  | s25-t25-sut1
260 10.30.50.59  | s26-t25-tg1
261 10.30.50.69  | s27-t13-sut
262 n/a          | s20-t34-sut1
263 n/a          | s21-t34-sut2
264 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyUSB0
265 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyUSB1
266 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyUSB2
267 10.30.55.10  | s28-t26t35-tg1
268 10.30.55.11  | s29-t26-sut1
269 10.30.55.12  | s30-t35-sut1
270 10.30.55.13  | s31-t35-sut2
271 10.30.50.255 | Broadcast
272 10.30.55.17  | s32-t14-sut1
273 10.30.55.18  | s33-t27-sut1
274 10.30.55.19  | s34-t27-tg1
275 10.30.55.20  | s35-t28-sut1
276 10.30.55.21  | s36-t28-tg1
277 10.30.55.22  | s37-t29-sut1
278 10.30.55.23  | s38-t29-tg1
279
280 ### Management VLAN IP Addresses
281
282 Name                      | Comment
283 ------------------------- | -------
284 10.30.51.0                | network
285 10.30.51.1                | Router
286 10.30.51.2                | LF Reserved
287 10.30.51.3                | LF Reserved
288 10.30.51.4                | LF Reserved
289 10.30.51.5                | LF Reserved
290 10.30.51.6                | LF Reserved
291 10.30.51.7                | LF Reserved
292 10.30.51.8                | LF Reserved
293 10.30.51.9                | s22-t35-sut1 (netgate-1)
294 10.30.51.10               | s23-t35-sut2 (netgate-2)
295 10.30.51.11               | s24-t35-sut3 (netgate-3)
296 10.30.51.12               | softiron-1
297 10.30.51.13               | softiron-2
298 10.30.51.14               | softiron-3
299 10.30.51.15               | LF Reserved
300 10.30.51.16               | t1-tg1
301 10.30.51.17               | t1-sut1
302 10.30.51.18               | t1-sut2
303 10.30.51.20               | t2-tg1
304 10.30.51.21               | t2-sut1
305 10.30.51.22               | t2-sut2
306 10.30.51.24               | t3-tg1
307 10.30.51.25               | t3-sut1
308 10.30.51.26               | t3-sut-2
309 10.30.51.28               | t4-sut1
310 10.30.51.29               | s39-nomad
311 10.30.51.29               | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
312 10.30.51.30               | t4-sut3
313 10.30.51.30               | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
314 10.30.51.30               | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
315 10.30.51.36               | s17-t33-sut1
316 10.30.51.37               | s18-t33-sut2
317 10.30.51.41               | s20-t34-sut1
318 10.30.51.42               | s21-t34-sut2
319 10.30.51.44               | s3-t21-sut1
320 10.30.51.45               | s4-t21-tg1
321 10.30.51.46               | s11-t31-sut1
322 10.30.51.47               | s12-t31-sut2
323 10.30.51.48               | s13-t31-tg1
324 10.30.51.49               | s19-t33t34-tg1
325 10.30.51.50               | s1-t11-sut1
326 10.30.51.51               | s2-t12-sut1
327 10.30.51.52               | s5-t22-sut1
328 10.30.51.53               | s6-t22-tg1
329 10.30.51.54               | s7-t23-sut1
330 10.30.51.55               | s8-t23-tg1
331 10.30.51.56               | s9-t24-sut1
332 10.30.51.57               | s10-t24-tg1
333 10.30.51.58               | s14-t32-sut1
334 10.30.51.59               | s15-t32-sut2
335 10.30.51.60               | s16-t32-tg1
336 10.30.51.61               | s25-t25-sut1
337 10.30.51.62               | s26-t25-tg1
338 10.30.51.69               | s27-t13-sut1
339 10.30.51.70-10.30.51.105  | VIRL1 TO BE VERIFIED
340 10.30.51.106-10.30.51.180 | VIRL2
341 10.30.51.181-10.30.51.254 | VIRL3
342 10.30.51.255              | Broadcast
343 10.32.8.10                | s28-t26t35-tg1
344 10.32.8.11                | s29-t26-sut1
345 10.32.8.12                | s30-t35-sut1
346 10.32.8.13                | s31-t35-sut2
347 10.32.8.17                | s32-t14-sut1
348 10.32.8.18                | s33-t27-sut1
349 10.32.8.19                | s34-t27-tg1
350 10.32.8.20                | s35-t28-sut1
351 10.32.8.21                | s36-t28-tg1
352 10.32.8.22                | s37-t29-sut1
353 10.32.8.23                | s38-t29-tg1
354
355 ## Server Specifications
356
357 ### Server Types
358
359 FD.io CSIT lab contains following server types:
360 ```
361 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
362     - Quantity: 6 servers.
363     - Physical connectivity:
364         - CIMC and host management ports.
365         - NIC ports connected in 3-node topologies.
366     - Main HW configuration:
367         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
368         - Processors: 2* E5-2699v3 2.3 GHz.
369         - RAM Memory: 16* 32GB DDR4-2133MHz.
370         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
371     - NICs configuration:
372         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
373             - PCIe Slot1: Cisco VIC 1385 2p40GE.
374             - PCIe Slot2: Intel NIC x520 2p10GE.
375             - PCIe Slot3: empty.
376         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
377             - PCIe Slot4: Intel NIC xl710 2p40GE.
378             - PCIe Slot5: Intel NIC x710 2p10GE.
379             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
380         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
381 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
382     - Quantity: 3 servers.
383     - Physical connectivity:
384         - CIMC and host management ports.
385         - NIC ports connected in 3-node topologies.
386     - Main HW configuration:
387         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
388         - Processors: 2* E5-2699v3 2.3 GHz.
389         - RAM Memory: 16* 32GB DDR4-2133MHz.
390         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
391     - NICs configuration:
392         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
393             - PCIe Slot1: Intel NIC xl710 2p40GE.
394             - PCIe Slot2: Intel NIC x710 2p10GE.
395             - PCIe Slot3: Intel NIC x710 2p10GE.
396         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
397             - PCIe Slot4: Intel NIC xl710 2p40GE.
398             - PCIe Slot5: Intel NIC x710 2p10GE.
399             - PCIe Slot6: Intel NIC x710 2p10GE.
400         - MLOM slot: empty.
401 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
402     - Quantity: 3 servers.
403     - Physical connectivity:
404         - CIMC and host management ports.
405         - no NIC ports, standalone setup.
406     - Main HW configuration:
407         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
408         - Processors: 2* E5-2699v3 2.3 GHz.
409         - RAM Memory: 16* 32GB DDR4-2133MHz.
410         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
411     - NICs configuration:
412         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
413             - no cards.
414         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
415             - no cards.
416         - MLOM slot: empty.
417 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
418     - Quantity: ---
419     - Physical connectivity:
420         - IPMI and host management ports.
421         - NIC ports connected into 2-node and 3-node topologies.
422     - Main HW configuration:
423         - Chassis: SuperMicro SYS-7049GP-TRT.
424         - Motherboard: SuperMicro X11DPG-QT.
425         - Processors: 2* Intel Platinum 8180 2.5 GHz.
426         - RAM Memory: 16* 16GB DDR4-2666MHz.
427         - Disks: 2* 1.6TB 6G SATA SSD.
428     - NICs configuration:
429         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
430             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
431             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
432             - PCIe Slot9 5e:00.xx: empty.
433         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
434             - PCIe Slot6 86:00.xx: empty.
435             - PCIe Slot8 af:00.xx: empty.
436             - PCIe Slot10 d8:00.xx: empty.
437 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
438     - Quantity: ---
439     - Physical connectivity:
440         - IPMI and host management ports.
441         - NIC ports connected into 2-node and 3-node topologies.
442     - Main HW configuration:
443         - Chassis: SuperMicro SYS-7049GP-TRT.
444         - Motherboard: SuperMicro X11DPG-QT.
445         - Processors: 2* Intel Platinum 8180 2.5 GHz.
446         - RAM Memory: 16* 16GB DDR4-2666MHz.
447         - Disks: 2* 1.6TB 6G SATA SSD.
448     - NICs configuration:
449         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
450             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
451             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
452             - PCIe Slot9 5e:00.xx: empty.
453         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
454             - PCIe Slot6 86:00.xx: empty.
455             - PCIe Slot8 af:00.xx: empty.
456             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
457 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
458     - Quantity: 2
459     - Physical connectivity:
460         - IPMI(?) and host management ports.
461         - NIC ports connected into 3-node topology.
462     - Main HW configuration:
463         - Chassis: Huawei TaiShan 2280.
464         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
465         - RAM Memory: 8* 16GB DDR4-2400MT/s
466         - Disks: 1* 4TB SATA HDD
467     - NICs configuration:
468         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
469         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
470 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
471     - Quantity: 3
472     - Physical connectivity:
473         - Host management ports.
474         - NIC ports connected into 2-node and 3-node topologies.
475     - Main HW configuration:
476         - Chassis: MACCHIATObin.
477         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
478         - RAM Memory: 1* 16GB DDR4
479         - Disks: 1* 128GB(?) SATA SDD
480     - NICs configuration:
481         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
482 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
483     - Quantity: TBD based on testbed allocation.
484     - Physical connectivity:
485         - Management: serial Port (usb) for console
486         - NIC ports connected into 2-node.
487     - Main HW configuration:
488         - Chassis: Netgate XG-2758-1u
489         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
490         - RAM Memory: 16GB ECC
491         - Disks: 150 GB
492     - NICs configuration:
493         - 2x 10Gb Intel 82599ES
494         - 4x 1GB Intel I354
495 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
496     - Quantity: 2.
497     - Physical connectivity:
498         - IPMI and host management ports.
499         - NIC ports connected into 2-node and 3-node topologies.
500     - Main HW configuration:
501         - Chassis: SuperMicro SYS-7049GP-TRT.
502         - Motherboard: SuperMicro X11DPG-QT.
503         - Processors: 2* Intel Platinum 8180 2.5 GHz.
504         - RAM Memory: 16* 16GB DDR4-2666MHz.
505         - Disks: 2* 1.6TB 6G SATA SSD.
506     - NICs configuration:
507         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
508             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
509             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
510             - PCIe Slot9 5e:00.xx: empty.
511         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
512             - PCIe Slot6 86:00.xx: empty.
513             - PCIe Slot8 af:00.xx: empty.
514             - PCIe Slot10 d8:00.xx: empty.
515 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
516     - Quantity: 1.
517     - Physical connectivity:
518         - Host management interface: 10/100/1000-BaseT.
519         - 8-port 10GE SFP+ integrated NIC.
520     - Main HW configuration:
521         - Chassis: PS10GE4NG.
522         - Motherboard: SuperMicro X11DPG-QT.
523         - Processors: Quad-Core, Intel Processor.
524         - HW accelerators: FPGA offload.
525         - RAM Memory: 64GB.
526         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
527         - Physical Interfaces: 4 * 10GE SFP+.
528         - Operating System: Native IxOS.
529     - Interface configuration:
530         - Port-1: 10GE SFP+.
531         - Port-2: 10GE SFP+.
532         - Port-3: 10GE SFP+.
533         - Port-4: 10GE SFP+.
534 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
535     - Quantity: 1.
536     - Physical connectivity:
537         - IPMI and host management ports.
538         - NIC ports.
539     - Main HW configuration:
540         - Chassis: SuperMicro SYS-7049GP-TRT.
541         - Motherboard: SuperMicro X11DPG-QT.
542         - Processors: 2* Intel Platinum 8180 2.5 GHz.
543         - RAM Memory: 16* 16GB DDR4-2666MHz.
544         - Disks: 2* 1.6TB 6G SATA SSD.
545     - NICs configuration:
546         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
547             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
548             - PCIe Slot4 3b:00.xx: empty.
549             - PCIe Slot9 5e:00.xx: empty.
550         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
551             - PCIe Slot6 86:00.xx: empty.
552             - PCIe Slot8 af:00.xx: empty.
553             - PCIe Slot10 d8:00.xx: empty.
554 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
555     - Quantity: 1
556     - Physical connectivity:
557         - IPMI and host management ports.
558         - NIC ports connected into 1-node topologies.
559     - Main HW configuration:
560         - Chassis: Gigabyte R181-T90 1U
561         - Motheboard: MT91-FS1
562         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
563         - RAM Memory: 4* 32GB RDIMM
564         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
565     - NICs configuration:
566         - Numa0:
567             - PCIe Slot1 05:00.xx: XL710-QDA2.
568             - PCIe Slot3 08:00.xx: XL710-QDA2.
569         - Numa1:
570             - PCIe Slot6 85:00.xx: XL710-QDA2.
571 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
572     - Quantity: 4
573     - Physical connectivity:
574         - IPMI and host management ports.
575         - NIC ports.
576     - Main HW configuration:
577         - Chassis: SuperMicro SYS-E300-9A
578         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
579         - RAM Memory: 32GB ECC
580         - Disks: 480 GB
581     - NICs configuration:
582         - 2x 10Gb Intel x553 fiber ports
583         - 2x 10Gb Intel x553 copper ports
584         - 4x 1GB Intel I350 ports
585
586 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
587     - Quantity: 1.
588     - Physical connectivity:
589         - IPMI and host management ports.
590         - NIC ports connected into 1-node testbed topologies.
591     - Main HW configuration:
592         - Chassis: SuperMicro SYS-7049GP-TRT.
593         - Motherboard: SuperMicro X11DPG-QT.
594         - Processors: 2* Intel Platinum 8280 2.7 GHz.
595         - RAM Memory: 12* 16GB DDR4-2933.
596         - Disks: 2* 1.92TB SATA SSD.
597     - NICs configuration:
598         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
599             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
600             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
601             - PCIe Slot9 5e:00.xx: empty.
602         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
603             - PCIe Slot6 86:00.xx: empty.
604             - PCIe Slot8 af:00.xx: empty.
605             - PCIe Slot10 d8:00.xx: empty.
606
607 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
608     - Quantity: 3
609     - Physical connectivity:
610         - IPMI and host management ports.
611         - NIC ports connected into 2-node testbed topologies.
612     - Main HW configuration:
613         - Chassis: SuperMicro SYS-7049GP-TRT.
614         - Motherboard: SuperMicro X11DPG-QT.
615         - Processors: 2* Intel Gold 6252N 2.3 GHz.
616         - RAM Memory: 12* 16GB DDR4-2933.
617         - Disks: 2* 1.92TB SATA SSD.
618     - NICs configuration:
619         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
620             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
621             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
622             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
623               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
624         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
625             - PCIe Slot6 86:00.xx: empty.
626             - PCIe Slot8 af:00.xx: empty.
627             - PCIe Slot10 d8:00.xx: empty.
628 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
629     - Quantity: 3.
630     - Physical connectivity:
631         - IPMI and host management ports.
632         - NIC ports connected into 2-node testbed topologies.
633     - Main HW configuration:
634         - Chassis: SuperMicro SYS-7049GP-TRT.
635         - Motherboard: SuperMicro X11DPG-QT.
636         - Processors: 2* Intel Platinum 8280 2.7 GHz.
637         - RAM Memory: 12* 16GB DDR4-2933.
638         - Disks: 2* 1.92TB SATA SSD.
639     - NICs configuration:
640         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
641             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
642             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
643             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
644               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
645         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
646             - PCIe Slot6 86:00.xx: empty.
647             - PCIe Slot8 af:00.xx: empty.
648             - PCIe Slot10 d8:00.xx: empty.
649
650 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
651     - Quantity: 3.
652     - Physical connectivity:
653         - CIMC and host management ports.
654         - no NIC ports, standalone setup.
655     - Main HW configuration:
656         - Chassis: SuperMicro 1029P-WTRT.
657         - Motherboard: SuperMicro X11DDW-NT.
658         - Processors: 2* Intel Platinum 8280 2.7 GHz.
659         - RAM Memory: 12* 16GB DDR4-2933.
660         - Disks: 4* 1.92TB SATA SSD.
661     - NICs configuration:
662         - Numa0:
663             - no cards.
664         - Numa1:
665             - no cards.
666 ```
667
668 ### Naming Convention
669
670 Following naming convention is used within this page to specify physical
671 connectivity and wiring across defined CSIT testbeds:
672
673 ```
674 - testbedname: testbedN.
675 - hostname:
676     - traffic-generator: tN-tgW.
677     - system-under-testX: tN-sutX.
678 - portnames:
679     - tN-tgW-cY/pZ.
680     - tN-sutX-cY/pZ.
681 - where:
682     - N - testbed number.
683     - tgW - server acts as traffic-generator with W index.
684     - sutX - server acts as system-under-test with X index.
685     - Y - PCIe slot number denoting a NIC card number within the host.
686     - Z - port number on the NIC card.
687 ```
688
689 ## Testbeds Configuration
690
691 ### Per Testbed Server Allocation and Naming
692
693 #### 1-Node-Skylake Servers (1n-skx) PROD
694
695 ```
696 - SUT [Server-Type-B6]:
697     - testbedname: testbed11.
698     - hostname: s1-t11-sut1.
699     - IPMI IP: 10.30.50.47
700     - Host IP: 10.30.51.50
701     - portnames:
702         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
703         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
704         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
705         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
706         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
707         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
708         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
709         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
710 - SUT [Server-Type-B6]:
711     - testbedname: testbed12.
712     - hostname: s2-t12-sut1.
713     - IPMI IP: 10.30.50.48
714     - Host IP: 10.30.51.51
715     - portnames:
716         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
717         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
718         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
719         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
720         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
721         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
722         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
723         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
724 ```
725
726 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
727
728 ```
729 - SUT [Server-Type-B9]:
730     - testbedname: testbed13.
731     - hostname: s27-t13-sut1.
732     - IPMI IP: 10.30.50.69
733     - Host IP: 10.30.51.69
734     - portnames:
735         - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
736         - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
737         - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
738         - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
739         - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
740         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
741 ```
742
743 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
744
745 ```
746 - SUT [Server-Type-C1]:
747     - testbedname: testbed11.
748     - hostname: s32-t14-sut1.
749     - IPMI IP: 10.30.55.17
750     - Host IP: 10.32.8.17
751     - portnames:
752         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
753         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
754         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
755         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
756         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
757         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
758         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
759         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
760 ```
761
762 #### 2-Node-Skylake Servers (2n-skx) PROD
763
764 ```
765 - SUT [Server-Type-B1]:
766     - testbedname: testbed21.
767     - hostname: s3-t21-sut1.
768     - IPMI IP: 10.30.50.41
769     - Host IP: 10.30.51.44
770     - portnames:
771         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
772         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
773         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
774         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
775         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
776         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
777 - TG [Server-Type-B2]:
778     - testbedname: testbed21.
779     - hostname: s4-t21-tg1.
780     - IPMI IP: 10.30.50.42
781     - Host IP: 10.30.51.45
782     - portnames:
783         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
784         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
785         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
786         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
787         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
788         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
789 - SUT [Server-Type-B1]:
790     - testbedname: testbed22.
791     - hostname: s5-t22-sut1.
792     - IPMI IP: 10.30.50.49
793     - Host IP: 10.30.51.52
794     - portnames:
795         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
796         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
797         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
798         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
799         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
800         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
801 - TG [Server-Type-B2]:
802     - testbedname: testbed22.
803     - hostname: s6-t22-tg1.
804     - IPMI IP: 10.30.50.50
805     - Host IP: 10.30.51.53
806     - portnames:
807         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
808         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
809         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
810         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
811         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
812         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
813 - SUT [Server-Type-B1]:
814     - testbedname: testbed23.
815     - hostname: s7-t23-sut1.
816     - IPMI IP: 10.30.50.51
817     - Host IP: 10.30.51.54
818     - portnames:
819         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
820         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
821         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
822         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
823         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
824         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
825 - TG [Server-Type-B2]:
826     - testbedname: testbed23.
827     - hostname: s8-t23-tg1.
828     - IPMI IP: 10.30.50.52
829     - Host IP: 10.30.51.55
830     - portnames:
831         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
832         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
833         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
834         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
835         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
836         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
837 - SUT [Server-Type-B1]:
838     - testbedname: testbed24.
839     - hostname: s9-t24-sut1.
840     - IPMI IP: 10.30.50.53
841     - Host IP: 10.30.51.56
842     - portnames:
843         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
844         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
845         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
846         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
847         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
848         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
849 - TG [Server-Type-B2]:
850     - testbedname: testbed24.
851     - hostname: s10-t24-tg1.
852     - IPMI IP: 10.30.50.54
853     - Host IP: 10.30.51.57
854     - portnames:
855         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
856         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
857         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
858         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
859         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
860         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
861 ```
862
863 #### 2-Node-Denverton Servers (2n-dnv) WIP
864
865 Note: ServerB28 (TG) is shared between testbed26 & testbed35
866
867 ```
868 - TG [Server-Type-B2]:
869     - testbednames: testbed26 and testbed35.
870     - hostname: s28-t26t35-tg1.
871     - IPMI IP: 10.30.55.10
872     - Host IP: 10.32.8.10
873     - portnames:
874         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
875         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
876         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
877         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
878         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
879         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
880         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
881         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
882         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
883         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
884         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
885         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
886 - SUT [Server-Type-B10]:
887     - testbednames: testbed26.
888     - hostname: s29-t26-sut1.
889     - IPMI IP: 10.30.55.11
890     - Host IP: 10.32.8.11
891     - portnames:
892         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
893         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
894         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
895         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
896 ```
897
898 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
899
900 ```
901 - SUT [Server-Type-B8]:
902     - testbedname: testbed25.
903     - hostname: s25-t25-sut1.
904     - IPMI IP: 10.30.50.58
905     - Host IP: 10.30.51.61
906     - portnames:
907         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
908         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
909         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
910         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
911 - TG [Server-Type-B7]:
912     - testbedname: testbed25.
913     - hostname: s26-t25-tg1.
914     - IPMI IP: 10.30.50.59
915     - Host IP: 10.30.51.62
916     - portnames:
917         - s26-t25-tg1-p1 - 10GE-port1.
918         - s26-t25-tg1-p2 - 10GE-port2.
919         - s26-t25-tg1-p3 - 10GE-port3.
920         - s26-t25-tg1-p4 - 10GE-port4.
921 ```
922
923 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
924
925 ```
926 - SUT [Server-Type-C2]:
927     - testbedname: testbed27.
928     - hostname: s33-t27-sut1.
929     - IPMI IP: 10.30.55.18
930     - Host IP: 10.32.8.18
931     - portnames:
932         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
933         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
934         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
935         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
936         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
937         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
938         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
939         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
940 - TG [Server-Type-C3]:
941     - testbedname: testbed27.
942     - hostname: s34-t27-tg1.
943     - IPMI IP: 10.30.55.19
944     - Host IP: 10.32.8.19
945     - portnames:
946         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
947         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
948         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
949         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
950         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
951         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
952         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
953         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
954 - SUT [Server-Type-C2]:
955     - testbedname: testbed28.
956     - hostname: s35-t28-sut1.
957     - IPMI IP: 10.30.55.20
958     - Host IP: 10.32.8.20
959     - portnames:
960         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
961         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
962         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
963         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
964         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
965         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
966         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
967         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
968 - TG [Server-Type-C3]:
969     - testbedname: testbed28.
970     - hostname: s36-t28-tg1.
971     - IPMI IP: 10.30.55.21
972     - Host IP: 10.32.8.21
973     - portnames:
974         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
975         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
976         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
977         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
978         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
979         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
980         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
981         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
982 - SUT [Server-Type-C2]:
983     - testbedname: testbed29.
984     - hostname: s37-t29-sut1.
985     - IPMI IP: 10.30.55.22
986     - Host IP: 10.32.8.22
987     - portnames:
988         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
989         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
990         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
991         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
992         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
993         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
994         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
995         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
996 - TG [Server-Type-C3]:
997     - testbedname: testbed29.
998     - hostname: s38-t29-tg1.
999     - IPMI IP: 10.30.55.23
1000     - Host IP: 10.32.8.23
1001     - portnames:
1002         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1003         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1004         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1005         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1006         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1007         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1008         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1009         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1010 ```
1011
1012 #### 3-Node-Haswell Servers (3n-hsw) PROD
1013
1014 ```
1015  1. SUT [Server-Type-A1]:
1016     - testbedname: testbed1.
1017     - hostname: t1-sut1.
1018     - CIMC IP: 10.30.50.17
1019     - Host IP: 10.30.51.17
1020     - portnames:
1021         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1022         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1023         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1024         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1025         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1026         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1027         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1028         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1029         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1030         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1031  2. SUT [Server-Type-A1]:
1032     - testbedname: testbed1.
1033     - hostname: t1-sut2.
1034     - CIMC IP: 10.30.50.18
1035     - Host IP: 10.30.51.18
1036     - portnames:
1037         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1038         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1039         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1040         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1041         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1042         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1043         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1044         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1045         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1046         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1047  3. TG [Server-Type-A2]:
1048     - testbedname: testbed1.
1049     - hostname: t1-tg1.
1050     - CIMC IP: 10.30.50.16
1051     - Host IP: 10.30.51.16
1052     - portnames:
1053         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1054         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1055         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1056         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1057         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1058         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1059         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1060         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1061         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1062         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1063         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1064         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1065  4. SUT [Server-Type-A1]:
1066     - testbedname: testbed2.
1067     - hostname: t2-sut1.
1068     - CIMC IP: 10.30.50.21
1069     - Host IP: 10.30.51.21
1070     - portnames:
1071         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1072         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1073         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1074         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1075         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1076         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1077         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1078         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1079         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1080         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1081  5. SUT [Server-Type-A1]:
1082     - testbedname: testbed2.
1083     - hostname: t2-sut2.
1084     - CIMC IP: 10.30.50.22
1085     - Host IP: 10.30.51.22
1086     - portnames:
1087         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1088         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1089         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1090         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1091         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1092         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1093         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1094         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1095         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1096         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1097  6. TG [Server-Type-A2]:
1098     - testbedname: testbed2.
1099     - hostname: t2-tg1.
1100     - CIMC IP: 10.30.50.20
1101     - Host IP: 10.30.51.20
1102     - portnames:
1103         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1104         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1105         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1106         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1107         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1108         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1109         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1110         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1111         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1112         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1113         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1114         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1115  7. SUT [Server-Type-A1]:
1116     - testbedname: testbed3.
1117     - hostname: t3-sut1.
1118     - CIMC IP: 10.30.50.25
1119     - Host IP: 10.30.51.25
1120     - portnames:
1121         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1122         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1123         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1124         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1125         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1126         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1127         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1128         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1129         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1130         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1131  8. SUT [Server-Type-A1]:
1132     - testbedname: testbed3.
1133     - hostname: t3-sut2.
1134     - CIMC IP: 10.30.50.26
1135     - Host IP: 10.30.51.26
1136     - portnames:
1137         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1138         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1139         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1140         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1141         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1142         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1143         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1144         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1145         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1146         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1147  9. TG [Server-Type-A2]:
1148     - testbedname: testbed3.
1149     - hostname: t3-tg1.
1150     - CIMC IP: 10.30.50.24
1151     - Host IP: 10.30.51.24
1152     - portnames:
1153         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1154         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1155         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1156         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1157         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1158         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1159         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1160         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1161         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1162         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1163         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1164         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1165 ```
1166
1167 #### 3-Node-Skylake Servers (3n-skx) PROD
1168
1169 ```
1170 - ServerB11 [Server-Type-B1]:
1171     - testbedname: testbed31.
1172     - hostname: s11-t31-sut1.
1173     - IPMI IP: 10.30.50.43
1174     - Host IP: 10.30.51.46
1175     - portnames:
1176         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1177         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1178         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1179         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1180         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1181         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1182         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1183         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1184 - ServerB12 [Server-Type-B1]:
1185     - testbedname: testbed31.
1186     - hostname: s12-t31-sut2.
1187     - IPMI IP: 10.30.50.44
1188     - Host IP: 10.30.51.47
1189     - portnames:
1190         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1191         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1192         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1193         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1194         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1195         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1196         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1197         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1198 - ServerB13 [Server-Type-B2]:
1199     - testbedname: testbed31.
1200     - hostname: s13-t31-tg1.
1201     - IPMI IP: 10.30.50.45
1202     - Host IP: 10.30.51.48
1203     - portnames:
1204         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1205         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1206         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1207         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1208         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1209         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1210         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1211         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1212 - ServerB14 [Server-Type-B1]:
1213     - testbedname: testbed32.
1214     - hostname: s14-t32-sut1.
1215     - IPMI IP: 10.30.50.55
1216     - Host IP: 10.30.51.58
1217     - portnames:
1218         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1219         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1220         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1221         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1222         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1223         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1224         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1225         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1226 - ServerB15 [Server-Type-B1]:
1227     - testbedname: testbed32.
1228     - hostname: s15-t32-sut2.
1229     - IPMI IP: 10.30.50.56
1230     - Host IP: 10.30.51.59
1231     - portnames:
1232         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1233         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1234         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1235         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1236         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1237         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1238         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1239         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1240 - ServerB16 [Server-Type-B2]:
1241     - testbedname: testbed32.
1242     - hostname: s16-t32-tg1.
1243     - IPMI IP: 10.30.50.57
1244     - Host IP: 10.30.51.60
1245     - portnames:
1246         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1247         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1248         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1249         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1250         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1251         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1252         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1253         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1254 ```
1255
1256 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1257
1258 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1259
1260 ```
1261 - ServerB22 [Server-Type-B5]:
1262     - testbedname: testbed35.
1263     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1264     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1265     - Host IP: 10.30.51.9
1266     - portnames:
1267         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1268         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1269     - 1GB ports (tbd)
1270 - ServerB23 [Server-Type-B5]:
1271     - testbedname: testbed35.
1272     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1273     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1274     - Host IP: 10.30.51.10
1275     - portnames:
1276         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1277         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1278     - 1GB ports (tbd)
1279 - ServerB24 [Server-Type-B5]:
1280     - testbedname: testbed35.
1281     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1282     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1283     - Host IP: 10.30.51.11
1284     - portnames:
1285         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1286         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1287     - 1GB ports (tbd)
1288 ```
1289
1290 #### 3-Node-Taishan Servers (3n-tsh) WIP
1291
1292 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1293
1294 ```
1295 - ServerB17 [Server-Type-B3]:
1296     - testbedname: testbed33.
1297     - hostname: s17-t33-sut1.
1298     - IPMI IP: 10.30.50.36
1299     - Host IP: 10.30.51.36
1300     - portnames:
1301         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1302         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1303         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1304         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1305 - ServerB18 [Server-Type-B3]:
1306     - testbedname: testbed33.
1307     - hostname: s18-t33-sut2.
1308     - IPMI IP: 10.30.50.37
1309     - Host IP: 10.30.51.37
1310     - portnames:
1311         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1312         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1313         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1314         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1315 - ServerB19 [Server-Type-B2]:
1316     - testbednames: testbed33 and testbed34.
1317     - hostname: s19-t33t34-tg1.
1318     - IPMI IP: 10.30.50.46
1319     - Host IP: 10.30.51.49
1320     - portnames:
1321         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1322         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1323         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1324         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1325         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1326         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1327         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1328         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1329         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1330         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1331 - ServerB20 [Server-Type-B4]:
1332     - testbedname: testbed34.
1333     - hostname: s20-t34-sut1.
1334     - IPMI IP: N/A
1335     - Host IP: 10.30.51.41
1336     - portnames:
1337         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1338         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1339 - ServerB21 [Server-Type-B4]:
1340     - testbedname: testbed34.
1341     - hostname: s21-t34-sut2.
1342     - IPMI IP: N/A
1343     - Host IP: 10.30.51.42
1344     - portnames:
1345         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1346         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1347 ```
1348
1349 #### 3-Node-Denverton Servers (3n-dnv) WIP
1350
1351 ```
1352 - ServerB30 [Server-Type-B10]:
1353     - testbednames: testbed35.
1354     - hostname: s30-t35-sut1.
1355     - IPMI IP: 10.30.55.12
1356     - Host IP: 10.32.8.12
1357     - portnames:
1358         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1359         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1360         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1361         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1362 - ServerB31 [Server-Type-B10]:
1363     - testbednames: testbed35.
1364     - hostname: s31-t35-sut2.
1365     - IPMI IP: 10.30.55.13
1366     - Host IP: 10.32.8.13
1367     - portnames:
1368         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1369         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1370         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1371         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1372 ```
1373
1374 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1375
1376 ```
1377 To be completed.
1378 ```
1379
1380 ### Per Testbed Wiring
1381
1382 #### 1-Node-Skylake Wiring (1n-skx) PROD
1383
1384 ```
1385 - testbed11:
1386     - ring1 10GE-ports x710-4p10GE:
1387         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1388     - ring2 10GE-ports x710-4p10GE:
1389         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1390     - ring3 10GE-ports x710-4p10GE:
1391         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1392     - ring4 10GE-ports x710-4p10GE:
1393         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1394 - testbed12:
1395     - ring1 10GE-ports x710-4p10GE:
1396         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1397     - ring2 10GE-ports x710-4p10GE:
1398         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1399     - ring3 10GE-ports x710-4p10GE:
1400         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1401     - ring4 10GE-ports x710-4p10GE:
1402         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1403 ```
1404
1405 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1406
1407 ```
1408 - testbed13:
1409     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1410         - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1411     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1412         - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1413     - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1414         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1415 ```
1416
1417 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1418
1419 ```
1420 - testbed14:
1421     - ring1 10GE-ports x710-4p10GE:
1422         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1423     - ring2 10GE-ports x710-4p10GE:
1424         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1425     - ring3 10GE-ports x710-4p10GE:
1426         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1427     - ring4 10GE-ports x710-4p10GE:
1428         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1429 ```
1430
1431 #### 2-Node-Skylake Wiring (2n-skx) PROD
1432
1433 ```
1434 - testbed21:
1435     - ring1 10GE-ports x710-4p10GE on SUT:
1436         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1437         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1438     - ring2 10GE-ports x710-4p10GE on SUT:
1439         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1440         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1441     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1442         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1443         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1444 - testbed22:
1445     - ring1 10GE-ports x710-4p10GE on SUT:
1446         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1447         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1448     - ring2 10GE-ports x710-4p10GE on SUT:
1449         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1450         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1451     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1452         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1453         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1454 - testbed23:
1455     - ring1 10GE-ports x710-4p10GE on SUT:
1456         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1457         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1458     - ring2 10GE-ports x710-4p10GE on SUT:
1459         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1460         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1461     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1462         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1463         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1464 - testbed24:
1465     - ring1 10GE-ports x710-4p10GE on SUT:
1466         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1467         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1468     - ring2 10GE-ports x710-4p10GE on SUT:
1469         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1470         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1471     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1472         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1473         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1474 ```
1475
1476 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1477
1478 ```
1479 - testbed26:
1480     - ring1 10GE-ports x553 copper port on SUT:
1481         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1482         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1483     - ring2 10GE-ports x553 fiber port on SUT:
1484         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1485         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1486 ```
1487
1488 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1489
1490 ```
1491 - testbed25:
1492     - link1 10GE-port x710-4p10GE on SUT:
1493         - t25-tg1-p1 to t25-sut1-c2/p1.
1494     - link2 10GE-port x710-4p10GE on SUT:
1495         - t25-tg1-p2 to t25-sut1-c2/p2.
1496     - link3 10GE-port x710-4p10GE on SUT:
1497         - t25-tg1-p3 to t25-sut1-c2/p3.
1498     - link4 10GE-port x710-4p10GE on SUT:
1499         - t25-tg1-p4 to t25-sut1-c2/p4.
1500 ```
1501
1502 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1503
1504 ```
1505 - testbed27:
1506     - ring1 10GE-ports x710-4p10GE on SUT:
1507         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1508         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1509     - ring2 10GE-ports x710-4p10GE on SUT:
1510         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1511         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1512     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1513         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1514         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1515     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1516         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1517         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1518 - testbed28:
1519     - ring1 10GE-ports x710-4p10GE on SUT:
1520         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1521         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1522     - ring2 10GE-ports x710-4p10GE on SUT:
1523         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1524         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1525     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1526         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1527         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1528     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1529         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1530         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1531 - testbed29:
1532     - ring1 10GE-ports x710-4p10GE on SUT:
1533         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1534         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1535     - ring2 10GE-ports x710-4p10GE on SUT:
1536         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1537         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1538     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1539         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1540         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1541     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1542         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1543         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1544 ```
1545
1546 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1547
1548 ```
1549  1. testbed1:
1550     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1551         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1552         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1553         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1554     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1555         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1556         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1557         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1558     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1559         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1560         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1561         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1562     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1563         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1564         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1565         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1566     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1567         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1568         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1569         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1570     - TG loopback ports Intel NIC x710 2p10GE
1571         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1572
1573  2. testbed2:
1574     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1575         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1576         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1577         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1578     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1579         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1580         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1581         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1582     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1583         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1584         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1585         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1586     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1587         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1588         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1589         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1590     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1591         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1592         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1593         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1594     - TG loopback ports Intel NIC x710 2p10GE
1595         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1596
1597  3. testbed3:
1598     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1599         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1600         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1601         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1602     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1603         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1604         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1605         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1606     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1607         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1608         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1609         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1610     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1611         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1612         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1613         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1614     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1615         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1616         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1617         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1618     - TG loopback ports Intel NIC x710 2p10GE
1619         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1620 ```
1621
1622 #### 3-Node-Skylake Wiring (3n-skx) PROD
1623
1624 ```
1625 - testbed31:
1626     - ring1 10GE-ports x710-4p10GE on SUTs:
1627         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1628         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1629         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1630     - ring2 10GE-ports x710-4p10GE on SUT:
1631         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1632         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1633         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1634     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1635         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1636         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1637         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1638     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1639         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1640         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1641         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1642     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1643         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1644         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1645 - testbed32:
1646     - ring1 10GE-ports x710-4p10GE on SUTs:
1647         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1648         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1649         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1650     - ring2 10GE-ports x710-4p10GE on SUT:
1651         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1652         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1653         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1654     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1655         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1656         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1657         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1658     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1659         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1660         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1661         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1662     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1663         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1664         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1665 ```
1666
1667 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1668
1669 ```
1670 To be completed.
1671 ```
1672
1673 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1674
1675 ```
1676 - testbed33:
1677     - ring1 10GE-ports x520-2p10GE on SUTs:
1678         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1679         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1680         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1681     - ring2 25GE-ports cx4-2p25GE on SUTs:
1682         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1683         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1684         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1685 ```
1686
1687 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1688
1689 ```
1690 - testbed34:
1691     - ring1 10GE-ports Marvell on SUTs:
1692         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1693         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1694         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1695 ```
1696
1697 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1698
1699 ```
1700 - testbed35:
1701     - ring1 10GE-ports x553 copper port on SUTs:
1702         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1703         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1704         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1705     - ring2 10GE-ports x553 fiber port on SUTs:
1706         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1707         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1708         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1709 ```
1710
1711 ## Inventory
1712
1713 ### Appliances
1714
1715 ```
1716 1. Ixia PerfectStorm One Appliance
1717     - 1 * PS10GE4NG
1718         - Chassis: PS10GE4NG.
1719         - Motherboard: SuperMicro X11DPG-QT.
1720         - Processors: Quad-Core, Intel Processor.
1721         - HW accelerators: FPGA offload.
1722         - RAM Memory: 64GB.
1723         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1724         - Physical Interfaces: 4 * 10GE SFP+.
1725         - Operating System: Native IxOS.
1726 ```
1727
1728 ### Arm Servers
1729
1730 ```
1731 1. Arm Cortex A-72 servers
1732     - 1 * ThunderX2
1733         - Chassis: Marvell ThunderX2
1734         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1735         - RAM Memory: 4* 32GB RDIMM
1736         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1737     - 2 * Huawei TaiShan 2280.
1738         - Chassis: Huawei TaiShan 2280.
1739         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1740         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1741         - Disks: 1* 4TB SATA HDD.
1742     - 3 * MACCHIATObin
1743         - Chassis: MACCHIATObin.
1744         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1745         - RAM Memory: 1* 16GB DDR4.
1746         - Disks: 1* 128GB(?) SATA SDD.
1747 ```
1748
1749 ### Xeon and Atom Servers
1750
1751 ```
1752 1. Intel Xeon servers:
1753     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1754         - Chassis: SuperMicro SYS-7049GP-TRT.
1755         - Motherboard: SuperMicro X11DPG-QT.
1756         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1757         - RAM Memory: 16* 16GB DDR4-2666MHz.
1758         - Disks: 2* 1.6TB 6G SATA SSD.
1759 2. Intel Atom servers with Rangely processors.
1760     - 3 * Netgate XG-2758-1u
1761         - Chassis: Netgate XG-2758-1u
1762         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1763         - RAM Memory: 16GB ECC
1764         - Disks: 150 GB
1765 ```
1766
1767 ### Network Interface Cards
1768
1769 ```
1770 1. 10GE NICs
1771     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1772     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1773     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1774 2. 25GE NICs
1775     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1776 3. 40GE NICs
1777     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1778 4. 100GE NICs
1779     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1780 ```
1781
1782 ### Pluggables and Cables
1783
1784 Pluggables:
1785
1786 ```
1787 1. 10GE SFP+
1788     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1789     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1790 2. 25GE SFP28
1791     - None
1792 3. 40GE QSFP+
1793     - None
1794 4. 100GE
1795     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1796 ```
1797
1798 Standalone cables:
1799
1800 ```
1801 1. 10GE
1802     - None
1803 2. 25GE
1804     - None
1805 3. 40GE QSFP+
1806     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1807 4. 100GE
1808     - None
1809 ```
1810
1811 ### Other Parts