feat(tests): IPv6 fixes
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
16    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
18    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
19 1. [Server Management](#server-management)
20    1. [Requirements](#requirements)
21    1. [Addressing](#addressing)
22    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25    1. [Server Types](#server-types)
26    1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
34       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
36       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
37       1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
38       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
39       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
40       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
41       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
42    1. [Per Testbed Wiring](#per-testbed-wiring)
43       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
48       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
51       1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
52       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
53       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
54       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
55       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
56 1. [Inventory](#inventory)
57    1. [Appliances](#appliances)
58    1. [Arm Servers](#arm-servers)
59    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60    1. [Network Interface Cards](#network-interface-cards)
61    1. [Pluggables and Cables](#pluggables-and-cables)
62    1. [Other Parts](#other-parts)
63
64 ## Purpose
65
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
68
69 ## Testbeds Overview
70
71 ### Summary List
72
73 ```
74  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
75  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0    0
76  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0
77  3. 1-Node-ThunderX2   perf   tx2   na    1    1    .5   0    .5   0    0    0    1    0    0    0
78  4. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0
79  5. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0
80  6. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0
81  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0
82  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0
83  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0
84 10. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0    0
85 11. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0
86 12. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0
87 13. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0
88 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0
89 15. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2
90                                  Totals: 27   36   18   12   19    1    2    3    3    2    7    2
91 ```
92
93 ### 1-Node-Skylake Xeon Intel (1n-skx)
94
95 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
96 ports connected back-to-back ([Server Types](#server-types)).
97 Used for FD.io VPP_Device functional driver tests.
98
99 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
100
101 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
102 ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
104
105 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
106
107 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
108 NIC ports connected back-to-back ([Server Types](#server-types)).
109
110 Used for FD.io VPP_Device functional driver tests.
111
112 ### 2-Node-Skylake Xeon Intel (2n-skx)
113
114 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
115 (Server-Type-B2) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
118
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
120
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
125
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
127
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
132
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
134
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
139
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
141
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
146
147 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
148
149 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
150 one TG (Server-Type-B12) connected in a 2-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
153
154 ### 3-Node-Haswell Xeon Intel (3n-hsw)
155
156 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
157 TG (Server-Type-A2) connected in a 3-node circular topology
158 ([Server Types](#server-types)).
159 Used for FD.io performance tests.
160
161 ### 3-Node-Skylake Xeon Intel (3n-skx)
162
163 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
164 TG (Server-Type-B2) connected in a 3-node circular topology.
165 Used for FD.io performance tests.
166
167 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
168
169 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
170 TG (Server-Type-B12) connected in a 3-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
173
174 ### 3-Node-Rangeley Atom Testbeds
175
176 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
177 TG (Server-Type-2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
180
181 ## Server Management
182
183 ### Requirements
184
185 For management purposes, each server must have following two ports
186 connected to the management network:
187
188 ```
189 - 1GE IPMI port
190   - IPMI - Intelligent Platform Management Interface.
191   - Required for access to embedded server management with WebUI, CLI,
192     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
193 - 1GE/10GE/40GE management port
194   - hostOS management port for general system management.
195 ```
196
197 ### Addressing
198
199 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
200 Management port, which are connected to two different VLANs.
201
202 ```
203 1. LOM (IPMI) VLAN:
204     - Subnet: 10.30.50.0/24
205     - Gateway: 10.30.50.1
206     - Broadcast: 10.30.50.255
207     - DNS1: 199.204.44.24
208     - DNS2: 199.204.47.54
209 2. Management Vlan:
210     - Subnet: 10.30.51.0/24
211     - Gateway: 10.30.51.1
212     - Broadcast: 10.30.51.255
213     - DNS1: 199.204.44.24
214     - DNS2: 199.204.47.54
215 ```
216
217 To access these hosts, VPN connection is required.
218
219 ### LOM (IPMI) VLAN IP Addresses
220
221 Name         | Comment
222 ------------ | -------
223 10.30.50.0   | network
224 10.30.51.1   | Router
225 10.30.50.2   | LF Reserved
226 10.30.50.3   | LF Reserved
227 10.30.50.4   | LF Reserved
228 10.30.50.5   | LF Reserved
229 10.30.50.6   | LF Reserved
230 10.30.50.7   | LF Reserved
231 10.30.50.8   | LF Reserved
232 10.30.50.9   | LF Reserved
233 10.30.50.10  | LF Reserved
234 10.30.50.11  | LF Reserved
235 10.30.50.12  | LF Reserved
236 10.30.50.13  | LF Reserved
237 10.30.50.14  | LF Reserved
238 10.30.50.15  | LF Reserved
239 10.30.50.16  | t1-tg1
240 10.30.50.17  | t1-sut1
241 10.30.50.18  | t1-sut2
242 10.30.50.20  | t2-tg1
243 10.30.50.21  | t2-sut1
244 10.30.50.22  | t2-sut2
245 10.30.50.24  | t3-tg1
246 10.30.50.25  | t3-sut1
247 10.30.50.26  | t3-sut-2
248 10.30.50.28  | s41-nomad
249 10.30.50.29  | s39-nomad
250 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
251 10.30.50.30  | s40-nomad
252 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
253 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
254 10.30.50.32  | s42-nomad (formerly nomad1)
255 10.30.50.33  | s43-nomad (formerly nomad2)
256 10.30.50.34  | s44-nomad (formerly nomad3)
257 10.30.50.35  | s45-nomad (formerly nomad4)
258 10.30.50.36  | s17-t33-sut1
259 10.30.50.37  | s18-t33-sut2
260 10.30.50.38  | fdio-marvell-dev
261 10.30.50.39  | s53-nomad
262 10.30.50.40  | s54-nomad
263 10.30.50.41  | s3-t21-sut1
264 10.30.50.42  | s4-t21-tg1
265 10.30.50.43  | s11-t31-sut1
266 10.30.50.44  | s12-t31-sut2
267 10.30.50.45  | s13-t31-tg1
268 10.30.50.46  | s19-t33t34-tg1
269 10.30.50.47  | s1-t11-sut1
270 10.30.50.48  | s2-t12-sut1
271 10.30.50.49  | s5-t22-sut1
272 10.30.50.50  | s6-t22-tg1
273 10.30.50.51  | s7-t23-sut1
274 10.30.50.52  | s8-t23-tg1
275 10.30.50.53  | s9-t24-sut1
276 10.30.50.54  | s10-t24-tg1
277 10.30.50.55  | s14-t32-sut1
278 10.30.50.56  | s15-t32-sut2
279 10.30.50.57  | s16-t32-tg1
280 10.30.50.58  | s25-t25-sut1
281 10.30.50.59  | s26-t25-tg1
282 10.30.50.65  | s52-nomad
283 10.30.50.66  | s51-nomad
284 10.30.50.67  | s49-nomad
285 10.30.50.68  | s50-nomad
286 10.30.50.69  | s27-t34-sut1
287 10.30.50.70  | s55-t36-sut1
288 10.30.50.71  | s56-t37-sut1
289 10.30.50.255 | Broadcast
290 n/a          | s20-t34-sut1
291 n/a          | s21-t34-sut2
292 10.30.55.0   | network
293 10.30.55.1   | Router
294 10.30.55.10  | s28-t26t35-tg1
295 10.30.55.11  | s29-t26-sut1
296 10.30.55.12  | s30-t35-sut1
297 10.30.55.13  | s31-t35-sut2
298 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
299 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
300 10.30.55.16  | s48-nomad (formerly server-type-c4-3)
301 10.30.55.17  | s32-t14-sut1
302 10.30.55.18  | s33-t27-sut1
303 10.30.55.19  | s34-t27-tg1
304 10.30.55.20  | s35-t28-sut1
305 10.30.55.21  | s36-t28-tg1
306 10.30.55.22  | s37-t29-sut1
307 10.30.55.23  | s38-t29-tg1
308 10.30.55.24  | s60-t210-sut1
309 10.30.55.25  | s61-t210-tg1
310 10.30.55.255 | Broadcast
311
312 ### Management VLAN IP Addresses
313
314 Name                      | Comment
315 ------------------------- | -------
316 10.30.51.0                | network
317 10.30.51.1                | Router
318 10.30.51.2                | LF Reserved
319 10.30.51.3                | LF Reserved
320 10.30.51.4                | LF Reserved
321 10.30.51.5                | LF Reserved
322 10.30.51.6                | LF Reserved
323 10.30.51.7                | LF Reserved
324 10.30.51.8                | LF Reserved
325 10.30.51.9                | s22-t35-sut1 (netgate-1)
326 10.30.51.10               | s23-t35-sut2 (netgate-2)
327 10.30.51.11               | s24-t35-sut3 (netgate-3)
328 10.30.51.12               | softiron-1 (decommissioned)
329 10.30.51.13               | softiron-2 (decommissioned)
330 10.30.51.14               | softiron-3 (decommissioned)
331 10.30.51.15               | LF Reserved
332 10.30.51.16               | t1-tg1
333 10.30.51.17               | t1-sut1
334 10.30.51.18               | t1-sut2
335 10.30.51.20               | t2-tg1
336 10.30.51.21               | t2-sut1
337 10.30.51.22               | t2-sut2
338 10.30.51.24               | t3-tg1
339 10.30.51.25               | t3-sut1
340 10.30.51.26               | t3-sut-2
341 10.30.51.28               | s41-nomad
342 10.30.51.29               | s39-nomad
343 10.30.51.30               | s40-nomad
344 10.30.51.32               | s42-nomad (formerly nomad1)
345 10.30.51.33               | s43-nomad (formerly nomad2)
346 10.30.51.34               | s44-nomad (formerly nomad3)
347 10.30.51.35               | s45-nomad (formerly nomad4)
348 10.30.51.36               | s17-t33-sut1
349 10.30.51.37               | s18-t33-sut2
350 10.30.51.38               | fdio-marvell-dev
351 10.30.51.39               | s53-nomad
352 10.30.51.40               | s54-nomad
353 10.30.51.41               | s20-t34-sut1 (decommissioned)
354 10.30.51.42               | s21-t34-sut2 (decommissioned)
355 10.30.51.43               | fdio-mcbin3 (decommissioned)
356 10.30.51.44               | s3-t21-sut1
357 10.30.51.45               | s4-t21-tg1
358 10.30.51.46               | s11-t31-sut1
359 10.30.51.47               | s12-t31-sut2
360 10.30.51.48               | s13-t31-tg1
361 10.30.51.49               | s19-t33t34-tg1
362 10.30.51.50               | s1-t11-sut1
363 10.30.51.51               | s2-t12-sut1
364 10.30.51.52               | s5-t22-sut1
365 10.30.51.53               | s6-t22-tg1
366 10.30.51.54               | s7-t23-sut1
367 10.30.51.55               | s8-t23-tg1
368 10.30.51.56               | s9-t24-sut1
369 10.30.51.57               | s10-t24-tg1
370 10.30.51.58               | s14-t32-sut1
371 10.30.51.59               | s15-t32-sut2
372 10.30.51.60               | s16-t32-tg1
373 10.30.51.61               | s25-t25-sut1
374 10.30.51.62               | s26-t25-tg1
375 10.30.51.65               | s52-nomad
376 10.30.51.66               | s51-nomad
377 10.30.51.67               | s49-nomad
378 10.30.51.68               | s50-nomad
379 10.30.51.69               | s27-t34-sut1
380 10.30.51.70               | s55-t36-sut1
381 10.30.51.71               | s56-t37-sut1
382 10.30.51.72-10.30.51.105  | FREE
383 10.30.51.106-10.30.51.180 | FREE
384 10.30.51.181-10.30.51.254 | FREE
385 10.30.51.255              | Broadcast
386 10.32.8.0                 | network
387 10.32.8.1                 | Router
388 10.32.8.10                | s28-t26t35-tg1
389 10.32.8.11                | s29-t26-sut1
390 10.32.8.12                | s30-t35-sut1
391 10.32.8.13                | s31-t35-sut2
392 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
393 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
394 10.32.8.16                | s48-nomad (formerly server-type-c4-3)
395 10.32.8.17                | s32-t14-sut1
396 10.32.8.18                | s33-t27-sut1
397 10.32.8.19                | s34-t27-tg1
398 10.32.8.20                | s35-t28-sut1
399 10.32.8.21                | s36-t28-tg1
400 10.32.8.22                | s37-t29-sut1
401 10.32.8.23                | s38-t29-tg1
402 10.32.8.24                | s60-t210-sut1
403 10.32.8.25                | s61-t210-tg1
404 10.32.8.255               | Broadcast
405
406 ## Server Specifications
407
408 ### Server Types
409
410 FD.io CSIT lab contains following server types:
411 ```
412 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
413     - Quantity: 6 servers.
414     - Physical connectivity:
415         - CIMC and host management ports.
416         - NIC ports connected in 3-node topologies.
417     - Main HW configuration:
418         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419         - Processors: 2* E5-2699v3 2.3 GHz.
420         - RAM Memory: 16* 32GB DDR4-2133MHz.
421         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
422     - NICs configuration:
423         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
424             - PCIe Slot1: Cisco VIC 1385 2p40GE.
425             - PCIe Slot2: Intel NIC x520 2p10GE.
426             - PCIe Slot3: empty.
427         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
428             - PCIe Slot4: Intel NIC xl710 2p40GE.
429             - PCIe Slot5: Intel NIC x710 2p10GE.
430             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
431         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
432 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
433     - Quantity: 3 servers.
434     - Physical connectivity:
435         - CIMC and host management ports.
436         - NIC ports connected in 3-node topologies.
437     - Main HW configuration:
438         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
439         - Processors: 2* E5-2699v3 2.3 GHz.
440         - RAM Memory: 16* 32GB DDR4-2133MHz.
441         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
442     - NICs configuration:
443         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
444             - PCIe Slot1: Intel NIC xl710 2p40GE.
445             - PCIe Slot2: Intel NIC x710 2p10GE.
446             - PCIe Slot3: Intel NIC x710 2p10GE.
447         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
448             - PCIe Slot4: Intel NIC xl710 2p40GE.
449             - PCIe Slot5: Intel NIC x710 2p10GE.
450             - PCIe Slot6: Intel NIC x710 2p10GE.
451         - MLOM slot: empty.
452 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
453     - Quantity: 3 servers.
454     - Physical connectivity:
455         - CIMC and host management ports.
456         - no NIC ports, standalone setup.
457     - Main HW configuration:
458         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
459         - Processors: 2* E5-2699v3 2.3 GHz.
460         - RAM Memory: 16* 32GB DDR4-2133MHz.
461         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
462     - NICs configuration:
463         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
464             - no cards.
465         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
466             - no cards.
467         - MLOM slot: empty.
468 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
469     - Quantity: ---
470     - Physical connectivity:
471         - IPMI and host management ports.
472         - NIC ports connected into 2-node and 3-node topologies.
473     - Main HW configuration:
474         - Chassis: SuperMicro SYS-7049GP-TRT.
475         - Motherboard: SuperMicro X11DPG-QT.
476         - Processors: 2* Intel Platinum 8180 2.5 GHz.
477         - RAM Memory: 16* 16GB DDR4-2666MHz.
478         - Disks: 2* 1.6TB 6G SATA SSD.
479     - NICs configuration:
480         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
481             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
482             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
483             - PCIe Slot9 5e:00.xx: empty.
484         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
485             - PCIe Slot6 86:00.xx: empty.
486             - PCIe Slot8 af:00.xx: empty.
487             - PCIe Slot10 d8:00.xx: empty.
488 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
489     - Quantity: ---
490     - Physical connectivity:
491         - IPMI and host management ports.
492         - NIC ports connected into 2-node and 3-node topologies.
493     - Main HW configuration:
494         - Chassis: SuperMicro SYS-7049GP-TRT.
495         - Motherboard: SuperMicro X11DPG-QT.
496         - Processors: 2* Intel Platinum 8180 2.5 GHz.
497         - RAM Memory: 16* 16GB DDR4-2666MHz.
498         - Disks: 2* 1.6TB 6G SATA SSD.
499     - NICs configuration:
500         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
501             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
502             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
503             - PCIe Slot9 5e:00.xx: empty.
504         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
505             - PCIe Slot6 86:00.xx: empty.
506             - PCIe Slot8 af:00.xx: empty.
507             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
508 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
509     - Quantity: 2
510     - Physical connectivity:
511         - IPMI(?) and host management ports.
512         - NIC ports connected into 3-node topology.
513     - Main HW configuration:
514         - Chassis: Huawei TaiShan 2280.
515         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
516         - RAM Memory: 8* 16GB DDR4-2400MT/s
517         - Disks: 1* 4TB SATA HDD
518     - NICs configuration:
519         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
520         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
521 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
522     - Quantity: TBD based on testbed allocation.
523     - Physical connectivity:
524         - Management: serial Port (usb) for console
525         - NIC ports connected into 2-node.
526     - Main HW configuration:
527         - Chassis: Netgate XG-2758-1u
528         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
529         - RAM Memory: 16GB ECC
530         - Disks: 150 GB
531     - NICs configuration:
532         - 2x 10Gb Intel 82599ES
533         - 4x 1GB Intel I354
534 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
535     - Quantity: 2.
536     - Physical connectivity:
537         - IPMI and host management ports.
538         - NIC ports connected into 1-node topologies.
539     - Main HW configuration:
540         - Chassis: SuperMicro SYS-7049GP-TRT.
541         - Motherboard: SuperMicro X11DPG-QT.
542         - Processors: 2* Intel Platinum 8180 2.5 GHz.
543         - RAM Memory: 16* 16GB DDR4-2666MHz.
544         - Disks: 2* 1.6TB 6G SATA SSD.
545     - NICs configuration:
546         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
547             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
548             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
549             - PCIe Slot9 5e:00.xx: empty.
550         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
551             - PCIe Slot6 86:00.xx: empty.
552             - PCIe Slot8 af:00.xx: empty.
553             - PCIe Slot10 d8:00.xx: empty.
554 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
555     - Quantity: 1.
556     - Physical connectivity:
557         - Host management interface: 10/100/1000-BaseT.
558         - 8-port 10GE SFP+ integrated NIC.
559     - Main HW configuration:
560         - Chassis: PS10GE4NG.
561         - Motherboard: SuperMicro X11DPG-QT.
562         - Processors: Quad-Core, Intel Processor.
563         - HW accelerators: FPGA offload.
564         - RAM Memory: 64GB.
565         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
566         - Physical Interfaces: 4 * 10GE SFP+.
567         - Operating System: Native IxOS.
568     - Interface configuration:
569         - Port-1: 10GE SFP+.
570         - Port-2: 10GE SFP+.
571         - Port-3: 10GE SFP+.
572         - Port-4: 10GE SFP+.
573 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
574     - Quantity: 1.
575     - Physical connectivity:
576         - IPMI and host management ports.
577         - NIC ports.
578     - Main HW configuration:
579         - Chassis: SuperMicro SYS-7049GP-TRT.
580         - Motherboard: SuperMicro X11DPG-QT.
581         - Processors: 2* Intel Platinum 8180 2.5 GHz.
582         - RAM Memory: 16* 16GB DDR4-2666MHz.
583         - Disks: 2* 1.6TB 6G SATA SSD.
584     - NICs configuration:
585         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
586             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
587             - PCIe Slot4 3b:00.xx: empty.
588             - PCIe Slot9 5e:00.xx: empty.
589         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
590             - PCIe Slot6 86:00.xx: empty.
591             - PCIe Slot8 af:00.xx: empty.
592             - PCIe Slot10 d8:00.xx: empty.
593 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
594     - Quantity: 1
595     - Physical connectivity:
596         - IPMI and host management ports.
597         - NIC ports connected into 1-node topologies.
598     - Main HW configuration:
599         - Chassis: Gigabyte R181-T90 1U
600         - Motherboard: MT91-FS1
601         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
602         - RAM Memory: 4* 32GB RDIMM
603         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
604     - NICs configuration:
605         - Numa0:
606             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
607         - Numa1:
608             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
609 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
610     - Quantity: 4
611     - Physical connectivity:
612         - IPMI and host management ports.
613         - NIC ports.
614     - Main HW configuration:
615         - Chassis: SuperMicro SYS-E300-9A
616         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
617         - RAM Memory: 32GB ECC
618         - Disks: 480 GB
619     - NICs configuration:
620         - 2x 10Gb Intel x553 fiber ports
621         - 2x 10Gb Intel x553 copper ports
622         - 4x 1GB Intel I350 ports
623 13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
624     - Quantity: 2
625     - Physical connectivity:
626         - IPMI and host management ports.
627         - NIC ports connected into 1-node topologies.
628     - Main HW configuration:
629         - Chassis: GIGABYTE Rack Mount
630         - Motherboard: MT91-FS4-00
631         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
632         - RAM Memory: 16 * 16GB DIMM
633         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
634     - NICs configuration:
635         - Numa0:
636             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
637             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
638         - Numa1:
639             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
640             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
641 14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
642     - Quantity: ---
643     - Physical connectivity:
644         - IPMI and host management ports.
645         - NIC ports connected into 2-node and 3-node topologies.
646     - Main HW configuration:
647         - Chassis: SuperMicro SYS-7049GP-TRT.
648         - Motherboard: SuperMicro X11DPG-QT.
649         - Processors: 2* Intel Platinum 8180 2.5 GHz.
650         - RAM Memory: 16* 16GB DDR4-2666MHz.
651         - Disks: 2* 1.6TB 6G SATA SSD.
652     - NICs configuration:
653         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
654             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
655             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
656             - PCIe Slot9 5e:00.xx: empty.
657         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
658             - PCIe Slot6 86:00.xx: empty.
659             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
660             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
661
662 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
663     - Quantity: 1.
664     - Physical connectivity:
665         - IPMI and host management ports.
666         - NIC ports connected into 1-node testbed topologies.
667     - Main HW configuration:
668         - Chassis: SuperMicro SYS-7049GP-TRT.
669         - Motherboard: SuperMicro X11DPG-QT.
670         - Processors: 2* Intel Platinum 8280 2.7 GHz.
671         - RAM Memory: 12* 16GB DDR4-2933.
672         - Disks: 2* 1.92TB SATA SSD.
673     - NICs configuration:
674         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
675             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
676             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
677             - PCIe Slot9 5e:00.xx: empty.
678         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
679             - PCIe Slot6 86:00.xx: empty.
680             - PCIe Slot8 af:00.xx: empty.
681             - PCIe Slot10 d8:00.xx: empty.
682 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
683     - Quantity: 3
684     - Physical connectivity:
685         - IPMI and host management ports.
686         - NIC ports connected into 2-node testbed topologies.
687     - Main HW configuration:
688         - Chassis: SuperMicro SYS-7049GP-TRT.
689         - Motherboard: SuperMicro X11DPG-QT.
690         - Processors: 2* Intel Gold 6252N 2.3 GHz.
691         - RAM Memory: 12* 16GB DDR4-2933.
692         - Disks: 2* 1.92TB SATA SSD.
693     - NICs configuration:
694         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
695             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
696             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
697             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
698         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
699             - PCIe Slot6 86:00.xx: empty.
700             - PCIe Slot8 af:00.xx: empty.
701             - PCIe Slot10 d8:00.xx: empty.
702 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
703     - Quantity: 3.
704     - Physical connectivity:
705         - IPMI and host management ports.
706         - NIC ports connected into 2-node testbed topologies.
707     - Main HW configuration:
708         - Chassis: SuperMicro SYS-7049GP-TRT.
709         - Motherboard: SuperMicro X11DPG-QT.
710         - Processors: 2* Intel Platinum 8280 2.7 GHz.
711         - RAM Memory: 12* 16GB DDR4-2933.
712         - Disks: 2* 1.92TB SATA SSD.
713     - NICs configuration:
714         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
715             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
716             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
717             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
718         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
719             - PCIe Slot6 86:00.xx: empty.
720             - PCIe Slot8 af:00.xx: empty.
721             - PCIe Slot10 d8:00.xx: empty.
722 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
723     - Quantity: 3.
724     - Physical connectivity:
725         - CIMC and host management ports.
726         - no NIC ports, standalone setup.
727     - Main HW configuration:
728         - Chassis: SuperMicro 1029P-WTRT.
729         - Motherboard: SuperMicro X11DDW-NT.
730         - Processors: 2* Intel Platinum 8280 2.7 GHz.
731         - RAM Memory: 12* 16GB DDR4-2933.
732         - Disks: 4* 1.92TB SATA SSD.
733     - NICs configuration:
734         - Numa0:
735             - no cards.
736         - Numa1:
737             - no cards.
738
739 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
740     - Quantity: 1.
741     - Physical connectivity:
742         - IPMI and host management ports.
743         - NIC ports connected into 2-node testbed topologies.
744     - Main HW configuration:
745         - Chassis: SuperMicro AS-1114S-WTRT
746         - Processors: 1* AMD EPYC 7532 2.4 GHz.
747         - RAM Memory: 8* 32GB DDR4-2933.
748         - Disks: 1* 1TB SATA SSD.
749     - NICs configuration:
750         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
751             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
752             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
753             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
754 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
755     - Quantity: 1.
756     - Physical connectivity:
757         - IPMI and host management ports.
758         - NIC ports connected into 2-node testbed topologies.
759     - Main HW configuration:
760         - Chassis: SuperMicro AS-1114S-WTRT
761         - Processors: 1* AMD EPYC 7532 2.4 GHz.
762         - RAM Memory: 8* 32GB DDR4-2933.
763         - Disks: 1* 1TB SATA SSD.
764     - NICs configuration:
765         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
766             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
767             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
768             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
769 ```
770
771 ### Naming Convention
772
773 Following naming convention is used within this page to specify physical
774 connectivity and wiring across defined CSIT testbeds:
775
776 ```
777 - testbedname: testbedN.
778 - hostname:
779     - traffic-generator: tN-tgW.
780     - system-under-testX: tN-sutX.
781 - portnames:
782     - tN-tgW-cY/pZ.
783     - tN-sutX-cY/pZ.
784 - where:
785     - N - testbed number.
786     - tgW - server acts as traffic-generator with W index.
787     - sutX - server acts as system-under-test with X index.
788     - Y - PCIe slot number denoting a NIC card number within the host.
789     - Z - port number on the NIC card.
790 ```
791
792 ## Testbeds Configuration
793
794 ### Per Testbed Server Allocation and Naming
795
796 #### 1-Node-Skylake Servers (1n-skx) PROD
797
798 ```
799 - SUT [Server-Type-B6]:
800     - testbedname: testbed11.
801     - hostname: s1-t11-sut1.
802     - IPMI IP: 10.30.50.47
803     - Host IP: 10.30.51.50
804     - portnames:
805         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
806         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
807         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
808         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
809         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
810         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
811         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
812         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
813 - SUT [Server-Type-B6]:
814     - testbedname: testbed12.
815     - hostname: s2-t12-sut1.
816     - IPMI IP: 10.30.50.48
817     - Host IP: 10.30.51.51
818     - portnames:
819         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
820         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
821         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
822         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
823         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
824         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
825         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
826         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
827 ```
828
829 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
830
831 ```
832 - SUT [Server-Type-B11]:
833     - testbedname: testbed36
834     - hostname: s55-t36-sut1
835     - IPMI IP: 10.30.50.70
836     - Host IP: 10.30.51.70
837     - portnames:
838         - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
839         - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
840         - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
841         - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
842         - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
843         - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
844         - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
845         - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
846 - SUT [Server-Type-B11]:
847     - testbedname: testbed37
848     - hostname: s56-t37-sut1
849     - IPMI IP: 10.30.50.71
850     - Host IP: 10.30.51.71
851     - portnames:
852         - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
853         - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
854         - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
855         - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
856         - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
857         - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
858         - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
859         - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
860 ```
861
862 #### 1-Node-Cascadelake Servers (1n-clx) PROD
863
864 ```
865 - SUT [Server-Type-C1]:
866     - testbedname: testbed11.
867     - hostname: s32-t14-sut1.
868     - IPMI IP: 10.30.55.17
869     - Host IP: 10.32.8.17
870     - portnames:
871         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
872         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
873         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
874         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
875         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
876         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
877         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
878         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
879 ```
880
881 #### 2-Node-Skylake Servers (2n-skx) PROD
882
883 ```
884 - SUT [Server-Type-B1]:
885     - testbedname: testbed21.
886     - hostname: s3-t21-sut1.
887     - IPMI IP: 10.30.50.41
888     - Host IP: 10.30.51.44
889     - portnames:
890         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
891         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
892         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
893         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
894         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
895         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
896 - TG [Server-Type-B2]:
897     - testbedname: testbed21.
898     - hostname: s4-t21-tg1.
899     - IPMI IP: 10.30.50.42
900     - Host IP: 10.30.51.45
901     - portnames:
902         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
903         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
904         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
905         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
906         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
907         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
908 - SUT [Server-Type-B1]:
909     - testbedname: testbed22.
910     - hostname: s5-t22-sut1.
911     - IPMI IP: 10.30.50.49
912     - Host IP: 10.30.51.52
913     - portnames:
914         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
915         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
916         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
917         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
918         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
919         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
920 - TG [Server-Type-B2]:
921     - testbedname: testbed22.
922     - hostname: s6-t22-tg1.
923     - IPMI IP: 10.30.50.50
924     - Host IP: 10.30.51.53
925     - portnames:
926         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
927         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
928         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
929         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
930         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
931         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
932 - SUT [Server-Type-B1]:
933     - testbedname: testbed23.
934     - hostname: s7-t23-sut1.
935     - IPMI IP: 10.30.50.51
936     - Host IP: 10.30.51.54
937     - portnames:
938         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
939         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
940         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
941         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
942         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
943         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
944 - TG [Server-Type-B2]:
945     - testbedname: testbed23.
946     - hostname: s8-t23-tg1.
947     - IPMI IP: 10.30.50.52
948     - Host IP: 10.30.51.55
949     - portnames:
950         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
951         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
952         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
953         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
954         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
955         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
956 - SUT [Server-Type-B1]:
957     - testbedname: testbed24.
958     - hostname: s9-t24-sut1.
959     - IPMI IP: 10.30.50.53
960     - Host IP: 10.30.51.56
961     - portnames:
962         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
963         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
964         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
965         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
966         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
967         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
968 - TG [Server-Type-B2]:
969     - testbedname: testbed24.
970     - hostname: s10-t24-tg1.
971     - IPMI IP: 10.30.50.54
972     - Host IP: 10.30.51.57
973     - portnames:
974         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
975         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
976         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
977         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
978         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
979         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
980 ```
981
982 #### 2-Node-Denverton Servers (2n-dnv) WIP
983
984 Note: ServerB28 (TG) is shared between testbed26 & testbed35
985
986 ```
987 - TG [Server-Type-B2]:
988     - testbednames: testbed26 and testbed35.
989     - hostname: s28-t26t35-tg1.
990     - IPMI IP: 10.30.55.10
991     - Host IP: 10.32.8.10
992     - portnames:
993         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
994         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
995         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
996         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
997         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
998         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
999         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1000         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1001         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1002         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1003         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1004         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1005 - SUT [Server-Type-B10]:
1006     - testbednames: testbed26.
1007     - hostname: s29-t26-sut1.
1008     - IPMI IP: 10.30.55.11
1009     - Host IP: 10.32.8.11
1010     - portnames:
1011         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1012         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1013         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1014         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1015 ```
1016
1017 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1018
1019 ```
1020 - SUT [Server-Type-B8]:
1021     - testbedname: testbed25.
1022     - hostname: s25-t25-sut1.
1023     - IPMI IP: 10.30.50.58
1024     - Host IP: 10.30.51.61
1025     - portnames:
1026         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1027         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1028         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1029         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1030 - TG [Server-Type-B7]:
1031     - testbedname: testbed25.
1032     - hostname: s26-t25-tg1.
1033     - IPMI IP: 10.30.50.59
1034     - Host IP: 10.30.51.62
1035     - portnames:
1036         - s26-t25-tg1-p1 - 10GE-port1.
1037         - s26-t25-tg1-p2 - 10GE-port2.
1038         - s26-t25-tg1-p3 - 10GE-port3.
1039         - s26-t25-tg1-p4 - 10GE-port4.
1040 ```
1041
1042 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1043
1044 ```
1045 - SUT [Server-Type-C2]:
1046     - testbedname: testbed27.
1047     - hostname: s33-t27-sut1.
1048     - IPMI IP: 10.30.55.18
1049     - Host IP: 10.32.8.18
1050     - portnames:
1051         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1052         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1053         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1054         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1055         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1056         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1057         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1058         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1059         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1060         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1061 - TG [Server-Type-C3]:
1062     - testbedname: testbed27.
1063     - hostname: s34-t27-tg1.
1064     - IPMI IP: 10.30.55.19
1065     - Host IP: 10.32.8.19
1066     - portnames:
1067         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1068         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1069         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1070         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1071         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1072         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1073         - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1074         - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1075         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1076         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1077 - SUT [Server-Type-C2]:
1078     - testbedname: testbed28.
1079     - hostname: s35-t28-sut1.
1080     - IPMI IP: 10.30.55.20
1081     - Host IP: 10.32.8.20
1082     - portnames:
1083         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1084         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1085         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1086         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1087         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1088         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1089         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1090         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1091         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1092         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1093 - TG [Server-Type-C3]:
1094     - testbedname: testbed28.
1095     - hostname: s36-t28-tg1.
1096     - IPMI IP: 10.30.55.21
1097     - Host IP: 10.32.8.21
1098     - portnames:
1099         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1100         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1101         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1102         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1103         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1104         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1105         - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1106         - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1107         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1108         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1109 - SUT [Server-Type-C2]:
1110     - testbedname: testbed29.
1111     - hostname: s37-t29-sut1.
1112     - IPMI IP: 10.30.55.22
1113     - Host IP: 10.32.8.22
1114     - portnames:
1115         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1116         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1117         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1118         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1119         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1120         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1121         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1122         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1123         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1124         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1125 - TG [Server-Type-C3]:
1126     - testbedname: testbed29.
1127     - hostname: s38-t29-tg1.
1128     - IPMI IP: 10.30.55.23
1129     - Host IP: 10.32.8.23
1130     - portnames:
1131         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1132         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1133         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1134         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1135         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137         - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1138         - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1139         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1140         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1141 ```
1142
1143 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1144
1145 ```
1146 - SUT [Server-Type-D1]:
1147     - testbedname: testbed210.
1148     - hostname: s60-t210-sut1.
1149     - IPMI IP: 10.30.55.24
1150     - Host IP: 10.32.8.24
1151     - portnames:
1152         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1153         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1154         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1155         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1156         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1157         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1158         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1159         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1160 - TG [Server-Type-D2]:
1161     - testbedname: testbed210.
1162     - hostname: s61-t210-tg1.
1163     - IPMI IP: 10.30.55.25
1164     - Host IP: 10.32.8.25
1165     - portnames:
1166         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1167         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1168         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1169         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1170         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1171         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1172         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1173         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1174 ```
1175
1176 #### 2-Node-ThunderX2 Servers (2x-tx2) WIP
1177
1178 Note: Server19 (TG) is shared between testbed33 & testbed34
1179
1180 ```
1181 - SUT [Server-Type-B9]:
1182     - testbedname: testbed34.
1183     - hostname: s27-t34-sut1.
1184     - IPMI IP: 10.30.50.69
1185     - Host IP: 10.30.51.69
1186     - portnames:
1187         - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1188         - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1189         - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1190         - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1191 - TG [Server-Type-B12]:
1192     - testbedname: testbed33 and testbed34.
1193     - hostname: s19-t33t34-tg1.
1194     - IPMI IP: 10.30.50.46
1195     - Host IP: 10.30.51.49
1196     - portnames:
1197         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1198         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1199         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1200         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1201         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1202         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1203         - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1204         - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1205         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1206         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1207         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1208         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1209 ```
1210
1211 #### 3-Node-Haswell Servers (3n-hsw) PROD
1212
1213 ```
1214  1. SUT [Server-Type-A1]:
1215     - testbedname: testbed1.
1216     - hostname: t1-sut1.
1217     - CIMC IP: 10.30.50.17
1218     - Host IP: 10.30.51.17
1219     - portnames:
1220         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1221         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1222         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1223         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1224         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1225         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1226         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1227         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1228         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1229         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1230  2. SUT [Server-Type-A1]:
1231     - testbedname: testbed1.
1232     - hostname: t1-sut2.
1233     - CIMC IP: 10.30.50.18
1234     - Host IP: 10.30.51.18
1235     - portnames:
1236         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1237         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1238         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1239         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1240         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1241         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1242         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1243         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1244         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1245         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1246  3. TG [Server-Type-A2]:
1247     - testbedname: testbed1.
1248     - hostname: t1-tg1.
1249     - CIMC IP: 10.30.50.16
1250     - Host IP: 10.30.51.16
1251     - portnames:
1252         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1253         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1254         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1255         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1256         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1257         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1258         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1259         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1260         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1261         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1262         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1263         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1264  4. SUT [Server-Type-A1]:
1265     - testbedname: testbed2.
1266     - hostname: t2-sut1.
1267     - CIMC IP: 10.30.50.21
1268     - Host IP: 10.30.51.21
1269     - portnames:
1270         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1271         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1272         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1273         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1274         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1275         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1276         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1277         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1278         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1279         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1280  5. SUT [Server-Type-A1]:
1281     - testbedname: testbed2.
1282     - hostname: t2-sut2.
1283     - CIMC IP: 10.30.50.22
1284     - Host IP: 10.30.51.22
1285     - portnames:
1286         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1287         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1288         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1289         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1290         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1291         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1292         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1293         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1294         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1295         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1296  6. TG [Server-Type-A2]:
1297     - testbedname: testbed2.
1298     - hostname: t2-tg1.
1299     - CIMC IP: 10.30.50.20
1300     - Host IP: 10.30.51.20
1301     - portnames:
1302         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1303         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1304         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1305         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1306         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1307         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1308         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1309         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1310         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1311         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1312         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1313         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1314  7. SUT [Server-Type-A1]:
1315     - testbedname: testbed3.
1316     - hostname: t3-sut1.
1317     - CIMC IP: 10.30.50.25
1318     - Host IP: 10.30.51.25
1319     - portnames:
1320         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1321         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1322         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1323         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1324         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1325         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1326         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1327         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1328         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1329         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1330  8. SUT [Server-Type-A1]:
1331     - testbedname: testbed3.
1332     - hostname: t3-sut2.
1333     - CIMC IP: 10.30.50.26
1334     - Host IP: 10.30.51.26
1335     - portnames:
1336         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1337         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1338         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1339         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1340         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1341         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1342         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1343         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1344         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1345         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1346  9. TG [Server-Type-A2]:
1347     - testbedname: testbed3.
1348     - hostname: t3-tg1.
1349     - CIMC IP: 10.30.50.24
1350     - Host IP: 10.30.51.24
1351     - portnames:
1352         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1353         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1354         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1355         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1356         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1357         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1358         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1359         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1360         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1361         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1362         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1363         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1364 ```
1365
1366 #### 3-Node-Skylake Servers (3n-skx) PROD
1367
1368 ```
1369 - ServerB11 [Server-Type-B1]:
1370     - testbedname: testbed31.
1371     - hostname: s11-t31-sut1.
1372     - IPMI IP: 10.30.50.43
1373     - Host IP: 10.30.51.46
1374     - portnames:
1375         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1376         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1377         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1378         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1379         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1380         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1381         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1382         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1383 - ServerB12 [Server-Type-B1]:
1384     - testbedname: testbed31.
1385     - hostname: s12-t31-sut2.
1386     - IPMI IP: 10.30.50.44
1387     - Host IP: 10.30.51.47
1388     - portnames:
1389         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1390         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1391         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1392         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1393         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1394         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1395         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1396         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1397 - ServerB13 [Server-Type-B2]:
1398     - testbedname: testbed31.
1399     - hostname: s13-t31-tg1.
1400     - IPMI IP: 10.30.50.45
1401     - Host IP: 10.30.51.48
1402     - portnames:
1403         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1404         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1405         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1406         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1407         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1408         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1409         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1410         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1411 - ServerB14 [Server-Type-B1]:
1412     - testbedname: testbed32.
1413     - hostname: s14-t32-sut1.
1414     - IPMI IP: 10.30.50.55
1415     - Host IP: 10.30.51.58
1416     - portnames:
1417         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1418         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1419         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1420         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1421         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1422         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1423         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1424         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1425 - ServerB15 [Server-Type-B1]:
1426     - testbedname: testbed32.
1427     - hostname: s15-t32-sut2.
1428     - IPMI IP: 10.30.50.56
1429     - Host IP: 10.30.51.59
1430     - portnames:
1431         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1432         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1433         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1434         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1435         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1436         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1437         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1438         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1439 - ServerB16 [Server-Type-B2]:
1440     - testbedname: testbed32.
1441     - hostname: s16-t32-tg1.
1442     - IPMI IP: 10.30.50.57
1443     - Host IP: 10.30.51.60
1444     - portnames:
1445         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1446         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1447         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1448         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1449         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1450         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1451         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1452         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1453 ```
1454
1455 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1456
1457 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1458
1459 ```
1460 - ServerB22 [Server-Type-B5]:
1461     - testbedname: testbed35.
1462     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1463     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1464     - Host IP: 10.30.51.9
1465     - portnames:
1466         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1467         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1468     - 1GB ports (tbd)
1469 - ServerB23 [Server-Type-B5]:
1470     - testbedname: testbed35.
1471     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1472     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1473     - Host IP: 10.30.51.10
1474     - portnames:
1475         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1476         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1477     - 1GB ports (tbd)
1478 - ServerB24 [Server-Type-B5]:
1479     - testbedname: testbed35.
1480     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1481     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1482     - Host IP: 10.30.51.11
1483     - portnames:
1484         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1485         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1486     - 1GB ports (tbd)
1487 ```
1488
1489 #### 3-Node-Taishan Servers (3n-tsh) PROD
1490
1491 Note: Server19 (TG) is shared between testbed33 & testbed34
1492
1493 ```
1494 - SUT [Server-Type-B3]:
1495     - testbedname: testbed33.
1496     - hostname: s17-t33-sut1.
1497     - IPMI IP: 10.30.50.36
1498     - Host IP: 10.30.51.36
1499     - portnames:
1500         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1501         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1502         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1503         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1504 - SUT [Server-Type-B3]:
1505     - testbedname: testbed33.
1506     - hostname: s18-t33-sut2.
1507     - IPMI IP: 10.30.50.37
1508     - Host IP: 10.30.51.37
1509     - portnames:
1510         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1511         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1512         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1513         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1514 - TG [Server-Type-B12]:
1515     - testbedname: testbed33 and testbed34.
1516     - hostname: s19-t33t34-tg1.
1517     - IPMI IP: 10.30.50.46
1518     - Host IP: 10.30.51.49
1519     - portnames:
1520         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1521         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1522         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1523         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1524         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1525         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1526         - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1527         - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1528         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1529         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1530         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1531         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1532 ```
1533
1534 #### 3-Node-Denverton Servers (3n-dnv) WIP
1535
1536 ```
1537 - ServerB30 [Server-Type-B10]:
1538     - testbednames: testbed35.
1539     - hostname: s30-t35-sut1.
1540     - IPMI IP: 10.30.55.12
1541     - Host IP: 10.32.8.12
1542     - portnames:
1543         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1544         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1545         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1546         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1547 - ServerB31 [Server-Type-B10]:
1548     - testbednames: testbed35.
1549     - hostname: s31-t35-sut2.
1550     - IPMI IP: 10.30.55.13
1551     - Host IP: 10.32.8.13
1552     - portnames:
1553         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1554         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1555         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1556         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1557 ```
1558
1559 ### Per Testbed Wiring
1560
1561 #### 1-Node-Skylake Wiring (1n-skx) PROD
1562
1563 ```
1564 - testbed11:
1565     - ring1 10GE-ports x710-4p10GE:
1566         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1567     - ring2 10GE-ports x710-4p10GE:
1568         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1569     - ring3 10GE-ports x710-4p10GE:
1570         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1571     - ring4 10GE-ports x710-4p10GE:
1572         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1573 - testbed12:
1574     - ring1 10GE-ports x710-4p10GE:
1575         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1576     - ring2 10GE-ports x710-4p10GE:
1577         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1578     - ring3 10GE-ports x710-4p10GE:
1579         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1580     - ring4 10GE-ports x710-4p10GE:
1581         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1582 ```
1583
1584 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1585
1586 ```
1587 - testbed36:
1588     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1589         - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1590     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1591         - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1592     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1593         - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1594     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1595         - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1596
1597 - testbed37:
1598     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1599         - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1600     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1601         - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1602     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1603         - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1604     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1605         - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1606 ```
1607
1608 #### 1-Node-Cascadelake Wiring (1n-clx) PROD
1609
1610 ```
1611 - testbed14:
1612     - ring1 10GE-ports x710-4p10GE:
1613         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1614     - ring2 10GE-ports x710-4p10GE:
1615         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1616     - ring3 10GE-ports x710-4p10GE:
1617         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1618     - ring4 10GE-ports x710-4p10GE:
1619         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1620 ```
1621
1622 #### 2-Node-Skylake Wiring (2n-skx) PROD
1623
1624 ```
1625 - testbed21:
1626     - ring1 10GE-ports x710-4p10GE on SUT:
1627         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1628         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1629     - ring2 10GE-ports x710-4p10GE on SUT:
1630         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1631         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1632     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1633         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1634         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1635 - testbed22:
1636     - ring1 10GE-ports x710-4p10GE on SUT:
1637         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1638         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1639     - ring2 10GE-ports x710-4p10GE on SUT:
1640         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1641         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1642     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1643         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1644         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1645 - testbed23:
1646     - ring1 10GE-ports x710-4p10GE on SUT:
1647         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1648         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1649     - ring2 10GE-ports x710-4p10GE on SUT:
1650         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1651         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1652     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1653         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1654         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1655 - testbed24:
1656     - ring1 10GE-ports x710-4p10GE on SUT:
1657         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1658         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1659     - ring2 10GE-ports x710-4p10GE on SUT:
1660         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1661         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1662     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1663         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1664         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1665 ```
1666
1667 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1668
1669 ```
1670 - testbed26:
1671     - ring1 10GE-ports x553 copper port on SUT:
1672         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1673         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1674     - ring2 10GE-ports x553 fiber port on SUT:
1675         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1676         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1677 ```
1678
1679 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1680
1681 ```
1682 - testbed25:
1683     - link1 10GE-port x710-4p10GE on SUT:
1684         - t25-tg1-p1 to t25-sut1-c2/p1.
1685     - link2 10GE-port x710-4p10GE on SUT:
1686         - t25-tg1-p2 to t25-sut1-c2/p2.
1687     - link3 10GE-port x710-4p10GE on SUT:
1688         - t25-tg1-p3 to t25-sut1-c2/p3.
1689     - link4 10GE-port x710-4p10GE on SUT:
1690         - t25-tg1-p4 to t25-sut1-c2/p4.
1691 ```
1692
1693 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1694
1695 ```
1696 - testbed27:
1697     - ring1 10GE-ports x710-4p10GE on SUT:
1698         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1699         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1700     - ring2 10GE-ports x710-4p10GE on SUT:
1701         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1702         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1703     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1704         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1705         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1706     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1707         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1708         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1709     - ring5 100GE-ports e810-2p100GE on SUT:
1710         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1711         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1712 - testbed28:
1713     - ring1 10GE-ports x710-4p10GE on SUT:
1714         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1715         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1716     - ring2 10GE-ports x710-4p10GE on SUT:
1717         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1718         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1719     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1720         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1721         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1722     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1723         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1724         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1725     - ring5 100GE-ports e810-2p100GE on SUT:
1726         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1727         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1728 - testbed29:
1729     - ring1 10GE-ports x710-4p10GE on SUT:
1730         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1731         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1732     - ring2 10GE-ports x710-4p10GE on SUT:
1733         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1734         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1735     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1736         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1737         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1738     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1739         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1740         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1741     - ring6 100GE-ports e810-2p100GE on SUT:
1742         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1743         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1744 ```
1745
1746 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1747
1748 ```
1749 - testbed210:
1750     - ring1 10GE-ports x710-4p10GE on SUT:
1751         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1752         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1753     - ring2 10GE-ports x710-4p10GE on SUT:
1754         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1755         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1756     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1757         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1758         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1759     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1760         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1761         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1762 ```
1763
1764 #### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
1765
1766 ```
1767 - testbed34:
1768     - ring1 10GE-ports x520-2p10GE on SUTs:
1769         - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
1770         - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
1771 ```
1772
1773
1774 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1775
1776 ```
1777  1. testbed1:
1778     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1779         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1780         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1781         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1782     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1783         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1784         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1785         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1786     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1787         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1788         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1789         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1790     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1791         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1792         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1793         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1794     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1795         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1796         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1797         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1798     - TG loopback ports Intel NIC x710 2p10GE
1799         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1800
1801  2. testbed2:
1802     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1803         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1804         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1805         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1806     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1807         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1808         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1809         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1810     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1811         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1812         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1813         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1814     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1815         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1816         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1817         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1818     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1819         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1820         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1821         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1822     - TG loopback ports Intel NIC x710 2p10GE
1823         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1824
1825  3. testbed3:
1826     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1827         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1828         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1829         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1830     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1831         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1832         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1833         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1834     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1835         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1836         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1837         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1838     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1839         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1840         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1841         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1842     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1843         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1844         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1845         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1846     - TG loopback ports Intel NIC x710 2p10GE
1847         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1848 ```
1849
1850 #### 3-Node-Skylake Wiring (3n-skx) PROD
1851
1852 ```
1853 - testbed31:
1854     - ring1 10GE-ports x710-4p10GE on SUTs:
1855         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1856         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1857         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1858     - ring2 10GE-ports x710-4p10GE on SUT:
1859         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1860         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1861         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1862     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1863         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1864         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1865         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1866     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1867         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1868         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1869         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1870     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1871         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1872         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1873 - testbed32:
1874     - ring1 10GE-ports x710-4p10GE on SUTs:
1875         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1876         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1877         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1878     - ring2 10GE-ports x710-4p10GE on SUT:
1879         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1880         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1881         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1882     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1883         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1884         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1885         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1886     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1887         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1888         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1889         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1890     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1891         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1892         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1893 ```
1894
1895 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1896
1897 ```
1898 To be completed.
1899 ```
1900
1901 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1902
1903 ```
1904 - testbed33:
1905     - ring1 10GE-ports x520-2p10GE on SUTs:
1906         - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1907         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1908         - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1909     - ring2 25GE-ports cx4-2p25GE on SUTs:
1910         - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1911         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1912         - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1913 ```
1914
1915 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1916
1917 ```
1918 - testbed35:
1919     - ring1 10GE-ports x553 copper port on SUTs:
1920         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1921         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1922         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1923     - ring2 10GE-ports x553 fiber port on SUTs:
1924         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1925         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1926         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1927 ```
1928
1929 ## Inventory
1930
1931 ### Appliances
1932
1933 ```
1934 1. Ixia PerfectStorm One Appliance
1935     - 1 * PS10GE4NG
1936         - Chassis: PS10GE4NG.
1937         - Motherboard: SuperMicro X11DPG-QT.
1938         - Processors: Quad-Core, Intel Processor.
1939         - HW accelerators: FPGA offload.
1940         - RAM Memory: 64GB.
1941         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1942         - Physical Interfaces: 4 * 10GE SFP+.
1943         - Operating System: Native IxOS.
1944 ```
1945
1946 ### Arm Servers
1947
1948 ```
1949 1. Arm Cortex A-72 servers
1950     - 2 * ThunderX2 (VPP Device)
1951         - Chassis: GIGABYTE Rack Mount
1952         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1953         - RAM Memory: 16* 16GB DIMM
1954         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1955     - 1 * ThunderX2 (Performance)
1956         - Chassis: GIGABYTE Rack Mount
1957         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1958         - RAM Memory: 4* 32GB RDIMM
1959         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1960     - 2 * Huawei TaiShan 2280.
1961         - Chassis: Huawei TaiShan 2280.
1962         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1963         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1964         - Disks: 1* 4TB SATA HDD.
1965 ```
1966
1967 ### Xeon and Atom Servers
1968
1969 ```
1970 1. Intel Xeon servers:
1971     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1972         - Chassis: SuperMicro SYS-7049GP-TRT.
1973         - Motherboard: SuperMicro X11DPG-QT.
1974         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1975         - RAM Memory: 16* 16GB DDR4-2666MHz.
1976         - Disks: 2* 1.6TB 6G SATA SSD.
1977 2. Intel Atom servers with Rangely processors.
1978     - 3 * Netgate XG-2758-1u
1979         - Chassis: Netgate XG-2758-1u
1980         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1981         - RAM Memory: 16GB ECC
1982         - Disks: 150 GB
1983 ```
1984
1985 ### Network Interface Cards
1986
1987 ```
1988 1. 10GE NICs
1989     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1990     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1991     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1992 2. 25GE NICs
1993     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1994 3. 40GE NICs
1995     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1996 4. 100GE NICs
1997     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1998 ```
1999
2000 ### Pluggables and Cables
2001
2002 Pluggables:
2003
2004 ```
2005 1. 10GE SFP+
2006     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
2007     - 80 * 10G SR optic (generic, "Intel" compatible branded)
2008 2. 25GE SFP28
2009     - None
2010 3. 40GE QSFP+
2011     - None
2012 4. 100GE
2013     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
2014 ```
2015
2016 Standalone cables:
2017
2018 ```
2019 1. 10GE
2020     - None
2021 2. 25GE
2022     - None
2023 3. 40GE QSFP+
2024     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
2025 4. 100GE
2026     - None
2027 ```
2028