Infra: Update Ansible ARM Nomad
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30       1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0
74  3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0
75  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0
76  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
77  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
78  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
79  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0
80  9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
84 13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
85 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0
86                                  Totals: 22   35   18   12   19    1    2    3    1    2    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
137
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
144
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
148
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
150
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 3-Node-MACCHIATObin Arm Marvell
157
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163 ### 3-Node-Rangeley Atom Testbeds
164
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ## Server Management
171
172 ### Requirements
173
174 For management purposes, each server must have following two ports
175 connected to the management network:
176
177 ```
178 - 1GE IPMI port
179   - IPMI - Intelligent Platform Management Interface.
180   - Required for access to embedded server management with WebUI, CLI,
181     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183   - hostOS management port for general system management.
184 ```
185
186 ### Addressing
187
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
190
191 ```
192 1. LOM (IPMI) VLAN:
193     - Subnet: 10.30.50.0/24
194     - Gateway: 10.30.50.1
195     - Broadcast: 10.30.50.255
196     - DNS1: 199.204.44.24
197     - DNS2: 199.204.47.54
198 2. Management Vlan:
199     - Subnet: 10.30.51.0/24
200     - Gateway: 10.30.51.1
201     - Broadcast: 10.30.51.255
202     - DNS1: 199.204.44.24
203     - DNS2: 199.204.47.54
204 ```
205
206 To access these hosts, VPN connection is required.
207
208 ### LOM (IPMI) VLAN IP Addresses
209
210 Name         | Comment
211 ------------ | -------
212 10.30.50.0   | network
213 10.30.51.1   | Router
214 10.30.50.2   | LF Reserved
215 10.30.50.3   | LF Reserved
216 10.30.50.4   | LF Reserved
217 10.30.50.5   | LF Reserved
218 10.30.50.6   | LF Reserved
219 10.30.50.7   | LF Reserved
220 10.30.50.8   | LF Reserved
221 10.30.50.9   | LF Reserved
222 10.30.50.10  | LF Reserved
223 10.30.50.11  | LF Reserved
224 10.30.50.12  | LF Reserved
225 10.30.50.13  | LF Reserved
226 10.30.50.14  | LF Reserved
227 10.30.50.15  | LF Reserved
228 10.30.50.16  | t1-tg1
229 10.30.50.17  | t1-sut1
230 10.30.50.18  | t1-sut2
231 10.30.50.20  | t2-tg1
232 10.30.50.21  | t2-sut1
233 10.30.50.22  | t2-sut2
234 10.30.50.24  | t3-tg1
235 10.30.50.25  | t3-sut1
236 10.30.50.26  | t3-sut-2
237 10.30.50.28  | s41-nomad
238 10.30.50.29  | s39-nomad
239 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30  | s40-nomad
241 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.32  | s42-nomad (formerly nomad1)
244 10.30.50.33  | s43-nomad (formerly nomad2)
245 10.30.50.34  | s44-nomad (formerly nomad3)
246 10.30.50.35  | s45-nomad (formerly nomad4)
247 10.30.50.36  | s17-t33-sut1
248 10.30.50.37  | s18-t33-sut2
249 10.30.50.38  | fdio-marvell-dev
250 10.30.50.39  | s53-nomad
251 10.30.50.40  | s54-nomad
252 10.30.50.41  | s3-t21-sut1
253 10.30.50.42  | s4-t21-tg1
254 10.30.50.43  | s11-t31-sut1
255 10.30.50.44  | s12-t31-sut2
256 10.30.50.45  | s13-t31-tg1
257 10.30.50.46  | s19-t33t34-tg1
258 10.30.50.47  | s1-t11-sut1
259 10.30.50.48  | s2-t12-sut1
260 10.30.50.49  | s5-t22-sut1
261 10.30.50.50  | s6-t22-tg1
262 10.30.50.51  | s7-t23-sut1
263 10.30.50.52  | s8-t23-tg1
264 10.30.50.53  | s9-t24-sut1
265 10.30.50.54  | s10-t24-tg1
266 10.30.50.55  | s14-t32-sut1
267 10.30.50.56  | s15-t32-sut2
268 10.30.50.57  | s16-t32-tg1
269 10.30.50.58  | s25-t25-sut1
270 10.30.50.59  | s26-t25-tg1
271 10.30.50.65  | s52-nomad
272 10.30.50.66  | s51-nomad (out of order)
273 10.30.50.67  | s49-nomad
274 10.30.50.68  | s50-nomad (out of order)
275 10.30.50.69  | s27-t13-sut
276 10.30.50.255 | Broadcast
277 n/a          | s20-t34-sut1
278 n/a          | s21-t34-sut2
279 10.30.55.0   | network
280 10.30.55.1   | Router
281 10.30.55.10  | s28-t26t35-tg1
282 10.30.55.11  | s29-t26-sut1
283 10.30.55.12  | s30-t35-sut1
284 10.30.55.13  | s31-t35-sut2
285 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
286 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
287 10.30.55.16  | s48-nomad (formerly server-type-c4-3)
288 10.30.55.17  | s32-t14-sut1
289 10.30.55.18  | s33-t27-sut1
290 10.30.55.19  | s34-t27-tg1
291 10.30.55.20  | s35-t28-sut1
292 10.30.55.21  | s36-t28-tg1
293 10.30.55.22  | s37-t29-sut1
294 10.30.55.23  | s38-t29-tg1
295 10.30.55.255 | Broadcast
296
297 ### Management VLAN IP Addresses
298
299 Name                      | Comment
300 ------------------------- | -------
301 10.30.51.0                | network
302 10.30.51.1                | Router
303 10.30.51.2                | LF Reserved
304 10.30.51.3                | LF Reserved
305 10.30.51.4                | LF Reserved
306 10.30.51.5                | LF Reserved
307 10.30.51.6                | LF Reserved
308 10.30.51.7                | LF Reserved
309 10.30.51.8                | LF Reserved
310 10.30.51.9                | s22-t35-sut1 (netgate-1)
311 10.30.51.10               | s23-t35-sut2 (netgate-2)
312 10.30.51.11               | s24-t35-sut3 (netgate-3)
313 10.30.51.12               | softiron-1
314 10.30.51.13               | softiron-2
315 10.30.51.14               | softiron-3
316 10.30.51.15               | LF Reserved
317 10.30.51.16               | t1-tg1
318 10.30.51.17               | t1-sut1
319 10.30.51.18               | t1-sut2
320 10.30.51.20               | t2-tg1
321 10.30.51.21               | t2-sut1
322 10.30.51.22               | t2-sut2
323 10.30.51.24               | t3-tg1
324 10.30.51.25               | t3-sut1
325 10.30.51.26               | t3-sut-2
326 10.30.51.28               | s41-nomad
327 10.30.51.29               | s39-nomad
328 10.30.51.30               | s40-nomad
329 10.30.51.32               | s42-nomad (formerly nomad1)
330 10.30.51.33               | s43-nomad (formerly nomad2)
331 10.30.51.34               | s44-nomad (formerly nomad3)
332 10.30.51.35               | s45-nomad (formerly nomad4)
333 10.30.51.36               | s17-t33-sut1
334 10.30.51.37               | s18-t33-sut2
335 10.30.51.38               | fdio-marvell-dev
336 10.30.51.39               | s53-nomad
337 10.30.51.40               | s54-nomad
338 10.30.51.41               | s20-t34-sut1
339 10.30.51.42               | s21-t34-sut2
340 10.30.51.44               | s3-t21-sut1
341 10.30.51.45               | s4-t21-tg1
342 10.30.51.46               | s11-t31-sut1
343 10.30.51.47               | s12-t31-sut2
344 10.30.51.48               | s13-t31-tg1
345 10.30.51.49               | s19-t33t34-tg1
346 10.30.51.50               | s1-t11-sut1
347 10.30.51.51               | s2-t12-sut1
348 10.30.51.52               | s5-t22-sut1
349 10.30.51.53               | s6-t22-tg1
350 10.30.51.54               | s7-t23-sut1
351 10.30.51.55               | s8-t23-tg1
352 10.30.51.56               | s9-t24-sut1
353 10.30.51.57               | s10-t24-tg1
354 10.30.51.58               | s14-t32-sut1
355 10.30.51.59               | s15-t32-sut2
356 10.30.51.60               | s16-t32-tg1
357 10.30.51.61               | s25-t25-sut1
358 10.30.51.62               | s26-t25-tg1
359 10.30.51.65               | s52-nomad
360 10.30.51.66               | s51-nomad (out of order)
361 10.30.51.67               | s49-nomad
362 10.30.51.68               | s50-nomad (out of order)
363 10.30.51.69               | s27-t13-sut1
364 10.30.51.70-10.30.51.105  | FREE
365 10.30.51.106-10.30.51.180 | FREE
366 10.30.51.181-10.30.51.254 | FREE
367 10.30.51.255              | Broadcast
368 10.32.8.0                 | network
369 10.32.8.1                 | Router
370 10.32.8.10                | s28-t26t35-tg1
371 10.32.8.11                | s29-t26-sut1
372 10.32.8.12                | s30-t35-sut1
373 10.32.8.13                | s31-t35-sut2
374 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
375 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
376 10.32.8.16                | s48-nomad (formerly server-type-c4-3)
377 10.32.8.17                | s32-t14-sut1
378 10.32.8.18                | s33-t27-sut1
379 10.32.8.19                | s34-t27-tg1
380 10.32.8.20                | s35-t28-sut1
381 10.32.8.21                | s36-t28-tg1
382 10.32.8.22                | s37-t29-sut1
383 10.32.8.23                | s38-t29-tg1
384 10.32.8.255               | Broadcast
385
386 ## Server Specifications
387
388 ### Server Types
389
390 FD.io CSIT lab contains following server types:
391 ```
392 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
393     - Quantity: 6 servers.
394     - Physical connectivity:
395         - CIMC and host management ports.
396         - NIC ports connected in 3-node topologies.
397     - Main HW configuration:
398         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
399         - Processors: 2* E5-2699v3 2.3 GHz.
400         - RAM Memory: 16* 32GB DDR4-2133MHz.
401         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
402     - NICs configuration:
403         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
404             - PCIe Slot1: Cisco VIC 1385 2p40GE.
405             - PCIe Slot2: Intel NIC x520 2p10GE.
406             - PCIe Slot3: empty.
407         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
408             - PCIe Slot4: Intel NIC xl710 2p40GE.
409             - PCIe Slot5: Intel NIC x710 2p10GE.
410             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
411         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
412 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
413     - Quantity: 3 servers.
414     - Physical connectivity:
415         - CIMC and host management ports.
416         - NIC ports connected in 3-node topologies.
417     - Main HW configuration:
418         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419         - Processors: 2* E5-2699v3 2.3 GHz.
420         - RAM Memory: 16* 32GB DDR4-2133MHz.
421         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
422     - NICs configuration:
423         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
424             - PCIe Slot1: Intel NIC xl710 2p40GE.
425             - PCIe Slot2: Intel NIC x710 2p10GE.
426             - PCIe Slot3: Intel NIC x710 2p10GE.
427         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
428             - PCIe Slot4: Intel NIC xl710 2p40GE.
429             - PCIe Slot5: Intel NIC x710 2p10GE.
430             - PCIe Slot6: Intel NIC x710 2p10GE.
431         - MLOM slot: empty.
432 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
433     - Quantity: 3 servers.
434     - Physical connectivity:
435         - CIMC and host management ports.
436         - no NIC ports, standalone setup.
437     - Main HW configuration:
438         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
439         - Processors: 2* E5-2699v3 2.3 GHz.
440         - RAM Memory: 16* 32GB DDR4-2133MHz.
441         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
442     - NICs configuration:
443         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
444             - no cards.
445         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
446             - no cards.
447         - MLOM slot: empty.
448 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
449     - Quantity: ---
450     - Physical connectivity:
451         - IPMI and host management ports.
452         - NIC ports connected into 2-node and 3-node topologies.
453     - Main HW configuration:
454         - Chassis: SuperMicro SYS-7049GP-TRT.
455         - Motherboard: SuperMicro X11DPG-QT.
456         - Processors: 2* Intel Platinum 8180 2.5 GHz.
457         - RAM Memory: 16* 16GB DDR4-2666MHz.
458         - Disks: 2* 1.6TB 6G SATA SSD.
459     - NICs configuration:
460         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
461             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
462             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
463             - PCIe Slot9 5e:00.xx: empty.
464         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
465             - PCIe Slot6 86:00.xx: empty.
466             - PCIe Slot8 af:00.xx: empty.
467             - PCIe Slot10 d8:00.xx: empty.
468 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
469     - Quantity: ---
470     - Physical connectivity:
471         - IPMI and host management ports.
472         - NIC ports connected into 2-node and 3-node topologies.
473     - Main HW configuration:
474         - Chassis: SuperMicro SYS-7049GP-TRT.
475         - Motherboard: SuperMicro X11DPG-QT.
476         - Processors: 2* Intel Platinum 8180 2.5 GHz.
477         - RAM Memory: 16* 16GB DDR4-2666MHz.
478         - Disks: 2* 1.6TB 6G SATA SSD.
479     - NICs configuration:
480         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
481             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
482             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
483             - PCIe Slot9 5e:00.xx: empty.
484         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
485             - PCIe Slot6 86:00.xx: empty.
486             - PCIe Slot8 af:00.xx: empty.
487             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
488 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
489     - Quantity: 2
490     - Physical connectivity:
491         - IPMI(?) and host management ports.
492         - NIC ports connected into 3-node topology.
493     - Main HW configuration:
494         - Chassis: Huawei TaiShan 2280.
495         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
496         - RAM Memory: 8* 16GB DDR4-2400MT/s
497         - Disks: 1* 4TB SATA HDD
498     - NICs configuration:
499         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
500         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
501 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
502     - Quantity: 3
503     - Physical connectivity:
504         - Host management ports.
505         - NIC ports connected into 2-node and 3-node topologies.
506     - Main HW configuration:
507         - Chassis: MACCHIATObin.
508         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
509         - RAM Memory: 1* 16GB DDR4
510         - Disks: 1* 128GB(?) SATA SDD
511     - NICs configuration:
512         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
513 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
514     - Quantity: TBD based on testbed allocation.
515     - Physical connectivity:
516         - Management: serial Port (usb) for console
517         - NIC ports connected into 2-node.
518     - Main HW configuration:
519         - Chassis: Netgate XG-2758-1u
520         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
521         - RAM Memory: 16GB ECC
522         - Disks: 150 GB
523     - NICs configuration:
524         - 2x 10Gb Intel 82599ES
525         - 4x 1GB Intel I354
526 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
527     - Quantity: 2.
528     - Physical connectivity:
529         - IPMI and host management ports.
530         - NIC ports connected into 2-node and 3-node topologies.
531     - Main HW configuration:
532         - Chassis: SuperMicro SYS-7049GP-TRT.
533         - Motherboard: SuperMicro X11DPG-QT.
534         - Processors: 2* Intel Platinum 8180 2.5 GHz.
535         - RAM Memory: 16* 16GB DDR4-2666MHz.
536         - Disks: 2* 1.6TB 6G SATA SSD.
537     - NICs configuration:
538         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
539             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
540             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
541             - PCIe Slot9 5e:00.xx: empty.
542         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
543             - PCIe Slot6 86:00.xx: empty.
544             - PCIe Slot8 af:00.xx: empty.
545             - PCIe Slot10 d8:00.xx: empty.
546 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
547     - Quantity: 1.
548     - Physical connectivity:
549         - Host management interface: 10/100/1000-BaseT.
550         - 8-port 10GE SFP+ integrated NIC.
551     - Main HW configuration:
552         - Chassis: PS10GE4NG.
553         - Motherboard: SuperMicro X11DPG-QT.
554         - Processors: Quad-Core, Intel Processor.
555         - HW accelerators: FPGA offload.
556         - RAM Memory: 64GB.
557         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
558         - Physical Interfaces: 4 * 10GE SFP+.
559         - Operating System: Native IxOS.
560     - Interface configuration:
561         - Port-1: 10GE SFP+.
562         - Port-2: 10GE SFP+.
563         - Port-3: 10GE SFP+.
564         - Port-4: 10GE SFP+.
565 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
566     - Quantity: 1.
567     - Physical connectivity:
568         - IPMI and host management ports.
569         - NIC ports.
570     - Main HW configuration:
571         - Chassis: SuperMicro SYS-7049GP-TRT.
572         - Motherboard: SuperMicro X11DPG-QT.
573         - Processors: 2* Intel Platinum 8180 2.5 GHz.
574         - RAM Memory: 16* 16GB DDR4-2666MHz.
575         - Disks: 2* 1.6TB 6G SATA SSD.
576     - NICs configuration:
577         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
578             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
579             - PCIe Slot4 3b:00.xx: empty.
580             - PCIe Slot9 5e:00.xx: empty.
581         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
582             - PCIe Slot6 86:00.xx: empty.
583             - PCIe Slot8 af:00.xx: empty.
584             - PCIe Slot10 d8:00.xx: empty.
585 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
586     - Quantity: 1
587     - Physical connectivity:
588         - IPMI and host management ports.
589         - NIC ports connected into 1-node topologies.
590     - Main HW configuration:
591         - Chassis: Gigabyte R181-T90 1U
592         - Motheboard: MT91-FS1
593         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
594         - RAM Memory: 4* 32GB RDIMM
595         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
596     - NICs configuration:
597         - Numa0:
598             - PCIe Slot1 05:00.xx: XL710-QDA2.
599             - PCIe Slot3 08:00.xx: XL710-QDA2.
600         - Numa1:
601             - PCIe Slot6 85:00.xx: XL710-QDA2.
602 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
603     - Quantity: 4
604     - Physical connectivity:
605         - IPMI and host management ports.
606         - NIC ports.
607     - Main HW configuration:
608         - Chassis: SuperMicro SYS-E300-9A
609         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
610         - RAM Memory: 32GB ECC
611         - Disks: 480 GB
612     - NICs configuration:
613         - 2x 10Gb Intel x553 fiber ports
614         - 2x 10Gb Intel x553 copper ports
615         - 4x 1GB Intel I350 ports
616
617 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
618     - Quantity: 1.
619     - Physical connectivity:
620         - IPMI and host management ports.
621         - NIC ports connected into 1-node testbed topologies.
622     - Main HW configuration:
623         - Chassis: SuperMicro SYS-7049GP-TRT.
624         - Motherboard: SuperMicro X11DPG-QT.
625         - Processors: 2* Intel Platinum 8280 2.7 GHz.
626         - RAM Memory: 12* 16GB DDR4-2933.
627         - Disks: 2* 1.92TB SATA SSD.
628     - NICs configuration:
629         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
630             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
631             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
632             - PCIe Slot9 5e:00.xx: empty.
633         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
634             - PCIe Slot6 86:00.xx: empty.
635             - PCIe Slot8 af:00.xx: empty.
636             - PCIe Slot10 d8:00.xx: empty.
637
638 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
639     - Quantity: 3
640     - Physical connectivity:
641         - IPMI and host management ports.
642         - NIC ports connected into 2-node testbed topologies.
643     - Main HW configuration:
644         - Chassis: SuperMicro SYS-7049GP-TRT.
645         - Motherboard: SuperMicro X11DPG-QT.
646         - Processors: 2* Intel Gold 6252N 2.3 GHz.
647         - RAM Memory: 12* 16GB DDR4-2933.
648         - Disks: 2* 1.92TB SATA SSD.
649     - NICs configuration:
650         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
651             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
652             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
653             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
654               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
655         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
656             - PCIe Slot6 86:00.xx: empty.
657             - PCIe Slot8 af:00.xx: empty.
658             - PCIe Slot10 d8:00.xx: empty.
659 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
660     - Quantity: 3.
661     - Physical connectivity:
662         - IPMI and host management ports.
663         - NIC ports connected into 2-node testbed topologies.
664     - Main HW configuration:
665         - Chassis: SuperMicro SYS-7049GP-TRT.
666         - Motherboard: SuperMicro X11DPG-QT.
667         - Processors: 2* Intel Platinum 8280 2.7 GHz.
668         - RAM Memory: 12* 16GB DDR4-2933.
669         - Disks: 2* 1.92TB SATA SSD.
670     - NICs configuration:
671         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
672             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
673             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
674             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
675               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
676         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
677             - PCIe Slot6 86:00.xx: empty.
678             - PCIe Slot8 af:00.xx: empty.
679             - PCIe Slot10 d8:00.xx: empty.
680
681 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
682     - Quantity: 3.
683     - Physical connectivity:
684         - CIMC and host management ports.
685         - no NIC ports, standalone setup.
686     - Main HW configuration:
687         - Chassis: SuperMicro 1029P-WTRT.
688         - Motherboard: SuperMicro X11DDW-NT.
689         - Processors: 2* Intel Platinum 8280 2.7 GHz.
690         - RAM Memory: 12* 16GB DDR4-2933.
691         - Disks: 4* 1.92TB SATA SSD.
692     - NICs configuration:
693         - Numa0:
694             - no cards.
695         - Numa1:
696             - no cards.
697 ```
698
699 ### Naming Convention
700
701 Following naming convention is used within this page to specify physical
702 connectivity and wiring across defined CSIT testbeds:
703
704 ```
705 - testbedname: testbedN.
706 - hostname:
707     - traffic-generator: tN-tgW.
708     - system-under-testX: tN-sutX.
709 - portnames:
710     - tN-tgW-cY/pZ.
711     - tN-sutX-cY/pZ.
712 - where:
713     - N - testbed number.
714     - tgW - server acts as traffic-generator with W index.
715     - sutX - server acts as system-under-test with X index.
716     - Y - PCIe slot number denoting a NIC card number within the host.
717     - Z - port number on the NIC card.
718 ```
719
720 ## Testbeds Configuration
721
722 ### Per Testbed Server Allocation and Naming
723
724 #### 1-Node-Skylake Servers (1n-skx) PROD
725
726 ```
727 - SUT [Server-Type-B6]:
728     - testbedname: testbed11.
729     - hostname: s1-t11-sut1.
730     - IPMI IP: 10.30.50.47
731     - Host IP: 10.30.51.50
732     - portnames:
733         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
734         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
735         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
736         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
737         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
738         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
739         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
740         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
741 - SUT [Server-Type-B6]:
742     - testbedname: testbed12.
743     - hostname: s2-t12-sut1.
744     - IPMI IP: 10.30.50.48
745     - Host IP: 10.30.51.51
746     - portnames:
747         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
748         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
749         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
750         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
751         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
752         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
753         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
754         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
755 ```
756
757 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
758
759 ```
760 - SUT [Server-Type-B9]:
761     - testbedname: testbed13.
762     - hostname: s27-t13-sut1.
763     - IPMI IP: 10.30.50.69
764     - Host IP: 10.30.51.69
765     - portnames:
766         - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
767         - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
768         - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
769         - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
770         - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
771         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
772 ```
773
774 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
775
776 ```
777 - SUT [Server-Type-C1]:
778     - testbedname: testbed11.
779     - hostname: s32-t14-sut1.
780     - IPMI IP: 10.30.55.17
781     - Host IP: 10.32.8.17
782     - portnames:
783         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
784         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
785         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
786         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
787         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
788         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
789         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
790         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
791 ```
792
793 #### 2-Node-Skylake Servers (2n-skx) PROD
794
795 ```
796 - SUT [Server-Type-B1]:
797     - testbedname: testbed21.
798     - hostname: s3-t21-sut1.
799     - IPMI IP: 10.30.50.41
800     - Host IP: 10.30.51.44
801     - portnames:
802         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
803         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
804         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
805         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
806         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
807         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
808 - TG [Server-Type-B2]:
809     - testbedname: testbed21.
810     - hostname: s4-t21-tg1.
811     - IPMI IP: 10.30.50.42
812     - Host IP: 10.30.51.45
813     - portnames:
814         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
815         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
816         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
817         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
818         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
819         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
820 - SUT [Server-Type-B1]:
821     - testbedname: testbed22.
822     - hostname: s5-t22-sut1.
823     - IPMI IP: 10.30.50.49
824     - Host IP: 10.30.51.52
825     - portnames:
826         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
827         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
828         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
829         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
830         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
831         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
832 - TG [Server-Type-B2]:
833     - testbedname: testbed22.
834     - hostname: s6-t22-tg1.
835     - IPMI IP: 10.30.50.50
836     - Host IP: 10.30.51.53
837     - portnames:
838         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
839         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
840         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
841         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
842         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
843         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
844 - SUT [Server-Type-B1]:
845     - testbedname: testbed23.
846     - hostname: s7-t23-sut1.
847     - IPMI IP: 10.30.50.51
848     - Host IP: 10.30.51.54
849     - portnames:
850         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
851         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
852         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
853         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
854         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
855         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
856 - TG [Server-Type-B2]:
857     - testbedname: testbed23.
858     - hostname: s8-t23-tg1.
859     - IPMI IP: 10.30.50.52
860     - Host IP: 10.30.51.55
861     - portnames:
862         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
863         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
864         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
865         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
866         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
867         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
868 - SUT [Server-Type-B1]:
869     - testbedname: testbed24.
870     - hostname: s9-t24-sut1.
871     - IPMI IP: 10.30.50.53
872     - Host IP: 10.30.51.56
873     - portnames:
874         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
875         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
876         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
877         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
878         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
879         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
880 - TG [Server-Type-B2]:
881     - testbedname: testbed24.
882     - hostname: s10-t24-tg1.
883     - IPMI IP: 10.30.50.54
884     - Host IP: 10.30.51.57
885     - portnames:
886         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
887         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
888         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
889         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
890         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
891         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
892 ```
893
894 #### 2-Node-Denverton Servers (2n-dnv) WIP
895
896 Note: ServerB28 (TG) is shared between testbed26 & testbed35
897
898 ```
899 - TG [Server-Type-B2]:
900     - testbednames: testbed26 and testbed35.
901     - hostname: s28-t26t35-tg1.
902     - IPMI IP: 10.30.55.10
903     - Host IP: 10.32.8.10
904     - portnames:
905         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
906         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
907         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
908         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
909         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
910         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
911         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
912         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
913         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
914         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
915         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
916         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
917 - SUT [Server-Type-B10]:
918     - testbednames: testbed26.
919     - hostname: s29-t26-sut1.
920     - IPMI IP: 10.30.55.11
921     - Host IP: 10.32.8.11
922     - portnames:
923         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
924         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
925         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
926         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
927 ```
928
929 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
930
931 ```
932 - SUT [Server-Type-B8]:
933     - testbedname: testbed25.
934     - hostname: s25-t25-sut1.
935     - IPMI IP: 10.30.50.58
936     - Host IP: 10.30.51.61
937     - portnames:
938         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
939         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
940         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
941         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
942 - TG [Server-Type-B7]:
943     - testbedname: testbed25.
944     - hostname: s26-t25-tg1.
945     - IPMI IP: 10.30.50.59
946     - Host IP: 10.30.51.62
947     - portnames:
948         - s26-t25-tg1-p1 - 10GE-port1.
949         - s26-t25-tg1-p2 - 10GE-port2.
950         - s26-t25-tg1-p3 - 10GE-port3.
951         - s26-t25-tg1-p4 - 10GE-port4.
952 ```
953
954 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
955
956 ```
957 - SUT [Server-Type-C2]:
958     - testbedname: testbed27.
959     - hostname: s33-t27-sut1.
960     - IPMI IP: 10.30.55.18
961     - Host IP: 10.32.8.18
962     - portnames:
963         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
964         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
965         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
966         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
967         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
968         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
969         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
970         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
971 - TG [Server-Type-C3]:
972     - testbedname: testbed27.
973     - hostname: s34-t27-tg1.
974     - IPMI IP: 10.30.55.19
975     - Host IP: 10.32.8.19
976     - portnames:
977         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
978         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
979         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
980         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
981         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
982         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
983         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
984         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
985 - SUT [Server-Type-C2]:
986     - testbedname: testbed28.
987     - hostname: s35-t28-sut1.
988     - IPMI IP: 10.30.55.20
989     - Host IP: 10.32.8.20
990     - portnames:
991         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
992         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
993         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
994         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
995         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
996         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
997         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
998         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
999 - TG [Server-Type-C3]:
1000     - testbedname: testbed28.
1001     - hostname: s36-t28-tg1.
1002     - IPMI IP: 10.30.55.21
1003     - Host IP: 10.32.8.21
1004     - portnames:
1005         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1006         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1007         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1008         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1009         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1010         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1011         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1012         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1013 - SUT [Server-Type-C2]:
1014     - testbedname: testbed29.
1015     - hostname: s37-t29-sut1.
1016     - IPMI IP: 10.30.55.22
1017     - Host IP: 10.32.8.22
1018     - portnames:
1019         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1020         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1021         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1022         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1023         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1024         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1025         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1026         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1027 - TG [Server-Type-C3]:
1028     - testbedname: testbed29.
1029     - hostname: s38-t29-tg1.
1030     - IPMI IP: 10.30.55.23
1031     - Host IP: 10.32.8.23
1032     - portnames:
1033         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1034         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1035         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1036         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1037         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1038         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1039         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1040         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1041 ```
1042
1043 #### 3-Node-Haswell Servers (3n-hsw) PROD
1044
1045 ```
1046  1. SUT [Server-Type-A1]:
1047     - testbedname: testbed1.
1048     - hostname: t1-sut1.
1049     - CIMC IP: 10.30.50.17
1050     - Host IP: 10.30.51.17
1051     - portnames:
1052         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1053         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1054         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1055         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1056         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1057         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1058         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1059         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1060         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1061         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1062  2. SUT [Server-Type-A1]:
1063     - testbedname: testbed1.
1064     - hostname: t1-sut2.
1065     - CIMC IP: 10.30.50.18
1066     - Host IP: 10.30.51.18
1067     - portnames:
1068         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1069         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1070         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1071         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1072         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1073         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1074         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1075         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1076         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1077         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1078  3. TG [Server-Type-A2]:
1079     - testbedname: testbed1.
1080     - hostname: t1-tg1.
1081     - CIMC IP: 10.30.50.16
1082     - Host IP: 10.30.51.16
1083     - portnames:
1084         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1085         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1086         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1087         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1088         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1089         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1090         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1091         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1092         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1093         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1094         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1095         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1096  4. SUT [Server-Type-A1]:
1097     - testbedname: testbed2.
1098     - hostname: t2-sut1.
1099     - CIMC IP: 10.30.50.21
1100     - Host IP: 10.30.51.21
1101     - portnames:
1102         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1103         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1104         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1105         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1106         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1107         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1108         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1109         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1110         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1111         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1112  5. SUT [Server-Type-A1]:
1113     - testbedname: testbed2.
1114     - hostname: t2-sut2.
1115     - CIMC IP: 10.30.50.22
1116     - Host IP: 10.30.51.22
1117     - portnames:
1118         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1119         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1120         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1121         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1122         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1123         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1124         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1125         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1126         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1127         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1128  6. TG [Server-Type-A2]:
1129     - testbedname: testbed2.
1130     - hostname: t2-tg1.
1131     - CIMC IP: 10.30.50.20
1132     - Host IP: 10.30.51.20
1133     - portnames:
1134         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1135         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1136         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1137         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1138         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1139         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1140         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1141         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1142         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1143         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1144         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1145         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1146  7. SUT [Server-Type-A1]:
1147     - testbedname: testbed3.
1148     - hostname: t3-sut1.
1149     - CIMC IP: 10.30.50.25
1150     - Host IP: 10.30.51.25
1151     - portnames:
1152         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1153         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1154         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1155         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1156         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1157         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1158         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1159         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1160         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1161         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1162  8. SUT [Server-Type-A1]:
1163     - testbedname: testbed3.
1164     - hostname: t3-sut2.
1165     - CIMC IP: 10.30.50.26
1166     - Host IP: 10.30.51.26
1167     - portnames:
1168         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1169         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1170         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1171         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1172         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1173         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1174         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1175         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1176         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1177         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1178  9. TG [Server-Type-A2]:
1179     - testbedname: testbed3.
1180     - hostname: t3-tg1.
1181     - CIMC IP: 10.30.50.24
1182     - Host IP: 10.30.51.24
1183     - portnames:
1184         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1185         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1186         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1187         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1188         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1189         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1190         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1191         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1192         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1193         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1194         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1195         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1196 ```
1197
1198 #### 3-Node-Skylake Servers (3n-skx) PROD
1199
1200 ```
1201 - ServerB11 [Server-Type-B1]:
1202     - testbedname: testbed31.
1203     - hostname: s11-t31-sut1.
1204     - IPMI IP: 10.30.50.43
1205     - Host IP: 10.30.51.46
1206     - portnames:
1207         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1208         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1209         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1210         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1211         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1212         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1213         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1214         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1215 - ServerB12 [Server-Type-B1]:
1216     - testbedname: testbed31.
1217     - hostname: s12-t31-sut2.
1218     - IPMI IP: 10.30.50.44
1219     - Host IP: 10.30.51.47
1220     - portnames:
1221         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1222         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1223         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1224         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1225         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1226         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1227         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1228         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1229 - ServerB13 [Server-Type-B2]:
1230     - testbedname: testbed31.
1231     - hostname: s13-t31-tg1.
1232     - IPMI IP: 10.30.50.45
1233     - Host IP: 10.30.51.48
1234     - portnames:
1235         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1236         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1237         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1238         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1239         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1240         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1241         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1242         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1243 - ServerB14 [Server-Type-B1]:
1244     - testbedname: testbed32.
1245     - hostname: s14-t32-sut1.
1246     - IPMI IP: 10.30.50.55
1247     - Host IP: 10.30.51.58
1248     - portnames:
1249         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1250         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1251         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1252         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1253         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1254         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1255         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1256         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1257 - ServerB15 [Server-Type-B1]:
1258     - testbedname: testbed32.
1259     - hostname: s15-t32-sut2.
1260     - IPMI IP: 10.30.50.56
1261     - Host IP: 10.30.51.59
1262     - portnames:
1263         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1264         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1265         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1266         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1267         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1268         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1269         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1270         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1271 - ServerB16 [Server-Type-B2]:
1272     - testbedname: testbed32.
1273     - hostname: s16-t32-tg1.
1274     - IPMI IP: 10.30.50.57
1275     - Host IP: 10.30.51.60
1276     - portnames:
1277         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1278         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1279         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1280         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1281         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1282         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1283         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1284         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1285 ```
1286
1287 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1288
1289 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1290
1291 ```
1292 - ServerB22 [Server-Type-B5]:
1293     - testbedname: testbed35.
1294     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1295     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1296     - Host IP: 10.30.51.9
1297     - portnames:
1298         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1299         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1300     - 1GB ports (tbd)
1301 - ServerB23 [Server-Type-B5]:
1302     - testbedname: testbed35.
1303     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1304     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1305     - Host IP: 10.30.51.10
1306     - portnames:
1307         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1308         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1309     - 1GB ports (tbd)
1310 - ServerB24 [Server-Type-B5]:
1311     - testbedname: testbed35.
1312     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1313     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1314     - Host IP: 10.30.51.11
1315     - portnames:
1316         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1317         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1318     - 1GB ports (tbd)
1319 ```
1320
1321 #### 3-Node-Taishan Servers (3n-tsh) WIP
1322
1323 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1324
1325 ```
1326 - ServerB17 [Server-Type-B3]:
1327     - testbedname: testbed33.
1328     - hostname: s17-t33-sut1.
1329     - IPMI IP: 10.30.50.36
1330     - Host IP: 10.30.51.36
1331     - portnames:
1332         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1333         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1334         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1335         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1336 - ServerB18 [Server-Type-B3]:
1337     - testbedname: testbed33.
1338     - hostname: s18-t33-sut2.
1339     - IPMI IP: 10.30.50.37
1340     - Host IP: 10.30.51.37
1341     - portnames:
1342         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1343         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1344         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1345         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1346 - ServerB19 [Server-Type-B2]:
1347     - testbednames: testbed33 and testbed34.
1348     - hostname: s19-t33t34-tg1.
1349     - IPMI IP: 10.30.50.46
1350     - Host IP: 10.30.51.49
1351     - portnames:
1352         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1353         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1354         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1355         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1356         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1357         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1358         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1359         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1360         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1361         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1362 - ServerB20 [Server-Type-B4]:
1363     - testbedname: testbed34.
1364     - hostname: s20-t34-sut1.
1365     - IPMI IP: N/A
1366     - Host IP: 10.30.51.41
1367     - portnames:
1368         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1369         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1370 - ServerB21 [Server-Type-B4]:
1371     - testbedname: testbed34.
1372     - hostname: s21-t34-sut2.
1373     - IPMI IP: N/A
1374     - Host IP: 10.30.51.42
1375     - portnames:
1376         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1377         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1378 ```
1379
1380 #### 3-Node-Denverton Servers (3n-dnv) WIP
1381
1382 ```
1383 - ServerB30 [Server-Type-B10]:
1384     - testbednames: testbed35.
1385     - hostname: s30-t35-sut1.
1386     - IPMI IP: 10.30.55.12
1387     - Host IP: 10.32.8.12
1388     - portnames:
1389         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1390         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1391         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1392         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1393 - ServerB31 [Server-Type-B10]:
1394     - testbednames: testbed35.
1395     - hostname: s31-t35-sut2.
1396     - IPMI IP: 10.30.55.13
1397     - Host IP: 10.32.8.13
1398     - portnames:
1399         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1400         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1401         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1402         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1403 ```
1404
1405 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1406
1407 ```
1408 To be completed.
1409 ```
1410
1411 ### Per Testbed Wiring
1412
1413 #### 1-Node-Skylake Wiring (1n-skx) PROD
1414
1415 ```
1416 - testbed11:
1417     - ring1 10GE-ports x710-4p10GE:
1418         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1419     - ring2 10GE-ports x710-4p10GE:
1420         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1421     - ring3 10GE-ports x710-4p10GE:
1422         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1423     - ring4 10GE-ports x710-4p10GE:
1424         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1425 - testbed12:
1426     - ring1 10GE-ports x710-4p10GE:
1427         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1428     - ring2 10GE-ports x710-4p10GE:
1429         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1430     - ring3 10GE-ports x710-4p10GE:
1431         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1432     - ring4 10GE-ports x710-4p10GE:
1433         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1434 ```
1435
1436 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1437
1438 ```
1439 - testbed13:
1440     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1441         - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1442     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1443         - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1444     - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1445         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1446 ```
1447
1448 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1449
1450 ```
1451 - testbed14:
1452     - ring1 10GE-ports x710-4p10GE:
1453         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1454     - ring2 10GE-ports x710-4p10GE:
1455         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1456     - ring3 10GE-ports x710-4p10GE:
1457         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1458     - ring4 10GE-ports x710-4p10GE:
1459         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1460 ```
1461
1462 #### 2-Node-Skylake Wiring (2n-skx) PROD
1463
1464 ```
1465 - testbed21:
1466     - ring1 10GE-ports x710-4p10GE on SUT:
1467         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1468         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1469     - ring2 10GE-ports x710-4p10GE on SUT:
1470         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1471         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1472     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1473         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1474         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1475 - testbed22:
1476     - ring1 10GE-ports x710-4p10GE on SUT:
1477         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1478         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1479     - ring2 10GE-ports x710-4p10GE on SUT:
1480         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1481         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1482     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1483         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1484         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1485 - testbed23:
1486     - ring1 10GE-ports x710-4p10GE on SUT:
1487         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1488         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1489     - ring2 10GE-ports x710-4p10GE on SUT:
1490         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1491         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1492     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1493         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1494         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1495 - testbed24:
1496     - ring1 10GE-ports x710-4p10GE on SUT:
1497         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1498         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1499     - ring2 10GE-ports x710-4p10GE on SUT:
1500         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1501         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1502     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1503         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1504         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1505 ```
1506
1507 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1508
1509 ```
1510 - testbed26:
1511     - ring1 10GE-ports x553 copper port on SUT:
1512         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1513         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1514     - ring2 10GE-ports x553 fiber port on SUT:
1515         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1516         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1517 ```
1518
1519 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1520
1521 ```
1522 - testbed25:
1523     - link1 10GE-port x710-4p10GE on SUT:
1524         - t25-tg1-p1 to t25-sut1-c2/p1.
1525     - link2 10GE-port x710-4p10GE on SUT:
1526         - t25-tg1-p2 to t25-sut1-c2/p2.
1527     - link3 10GE-port x710-4p10GE on SUT:
1528         - t25-tg1-p3 to t25-sut1-c2/p3.
1529     - link4 10GE-port x710-4p10GE on SUT:
1530         - t25-tg1-p4 to t25-sut1-c2/p4.
1531 ```
1532
1533 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1534
1535 ```
1536 - testbed27:
1537     - ring1 10GE-ports x710-4p10GE on SUT:
1538         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1539         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1540     - ring2 10GE-ports x710-4p10GE on SUT:
1541         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1542         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1543     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1544         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1545         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1546     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1547         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1548         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1549 - testbed28:
1550     - ring1 10GE-ports x710-4p10GE on SUT:
1551         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1552         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1553     - ring2 10GE-ports x710-4p10GE on SUT:
1554         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1555         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1556     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1557         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1558         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1559     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1560         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1561         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1562 - testbed29:
1563     - ring1 10GE-ports x710-4p10GE on SUT:
1564         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1565         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1566     - ring2 10GE-ports x710-4p10GE on SUT:
1567         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1568         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1569     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1570         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1571         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1572     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1573         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1574         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1575 ```
1576
1577 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1578
1579 ```
1580  1. testbed1:
1581     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1582         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1583         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1584         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1585     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1586         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1587         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1588         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1589     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1590         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1591         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1592         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1593     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1594         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1595         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1596         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1597     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1598         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1599         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1600         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1601     - TG loopback ports Intel NIC x710 2p10GE
1602         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1603
1604  2. testbed2:
1605     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1606         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1607         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1608         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1609     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1610         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1611         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1612         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1613     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1614         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1615         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1616         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1617     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1618         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1619         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1620         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1621     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1622         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1623         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1624         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1625     - TG loopback ports Intel NIC x710 2p10GE
1626         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1627
1628  3. testbed3:
1629     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1630         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1631         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1632         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1633     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1634         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1635         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1636         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1637     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1638         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1639         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1640         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1641     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1642         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1643         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1644         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1645     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1646         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1647         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1648         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1649     - TG loopback ports Intel NIC x710 2p10GE
1650         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1651 ```
1652
1653 #### 3-Node-Skylake Wiring (3n-skx) PROD
1654
1655 ```
1656 - testbed31:
1657     - ring1 10GE-ports x710-4p10GE on SUTs:
1658         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1659         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1660         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1661     - ring2 10GE-ports x710-4p10GE on SUT:
1662         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1663         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1664         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1665     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1666         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1667         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1668         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1669     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1670         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1671         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1672         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1673     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1674         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1675         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1676 - testbed32:
1677     - ring1 10GE-ports x710-4p10GE on SUTs:
1678         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1679         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1680         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1681     - ring2 10GE-ports x710-4p10GE on SUT:
1682         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1683         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1684         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1685     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1686         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1687         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1688         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1689     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1690         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1691         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1692         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1693     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1694         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1695         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1696 ```
1697
1698 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1699
1700 ```
1701 To be completed.
1702 ```
1703
1704 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1705
1706 ```
1707 - testbed33:
1708     - ring1 10GE-ports x520-2p10GE on SUTs:
1709         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1710         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1711         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1712     - ring2 25GE-ports cx4-2p25GE on SUTs:
1713         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1714         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1715         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1716 ```
1717
1718 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1719
1720 ```
1721 - testbed34:
1722     - ring1 10GE-ports Marvell on SUTs:
1723         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1724         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1725         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1726 ```
1727
1728 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1729
1730 ```
1731 - testbed35:
1732     - ring1 10GE-ports x553 copper port on SUTs:
1733         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1734         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1735         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1736     - ring2 10GE-ports x553 fiber port on SUTs:
1737         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1738         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1739         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1740 ```
1741
1742 ## Inventory
1743
1744 ### Appliances
1745
1746 ```
1747 1. Ixia PerfectStorm One Appliance
1748     - 1 * PS10GE4NG
1749         - Chassis: PS10GE4NG.
1750         - Motherboard: SuperMicro X11DPG-QT.
1751         - Processors: Quad-Core, Intel Processor.
1752         - HW accelerators: FPGA offload.
1753         - RAM Memory: 64GB.
1754         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1755         - Physical Interfaces: 4 * 10GE SFP+.
1756         - Operating System: Native IxOS.
1757 ```
1758
1759 ### Arm Servers
1760
1761 ```
1762 1. Arm Cortex A-72 servers
1763     - 1 * ThunderX2
1764         - Chassis: Marvell ThunderX2
1765         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1766         - RAM Memory: 4* 32GB RDIMM
1767         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1768     - 2 * Huawei TaiShan 2280.
1769         - Chassis: Huawei TaiShan 2280.
1770         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1771         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1772         - Disks: 1* 4TB SATA HDD.
1773     - 3 * MACCHIATObin
1774         - Chassis: MACCHIATObin.
1775         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1776         - RAM Memory: 1* 16GB DDR4.
1777         - Disks: 1* 128GB(?) SATA SDD.
1778 ```
1779
1780 ### Xeon and Atom Servers
1781
1782 ```
1783 1. Intel Xeon servers:
1784     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1785         - Chassis: SuperMicro SYS-7049GP-TRT.
1786         - Motherboard: SuperMicro X11DPG-QT.
1787         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1788         - RAM Memory: 16* 16GB DDR4-2666MHz.
1789         - Disks: 2* 1.6TB 6G SATA SSD.
1790 2. Intel Atom servers with Rangely processors.
1791     - 3 * Netgate XG-2758-1u
1792         - Chassis: Netgate XG-2758-1u
1793         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1794         - RAM Memory: 16GB ECC
1795         - Disks: 150 GB
1796 ```
1797
1798 ### Network Interface Cards
1799
1800 ```
1801 1. 10GE NICs
1802     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1803     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1804     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1805 2. 25GE NICs
1806     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1807 3. 40GE NICs
1808     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1809 4. 100GE NICs
1810     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1811 ```
1812
1813 ### Pluggables and Cables
1814
1815 Pluggables:
1816
1817 ```
1818 1. 10GE SFP+
1819     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1820     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1821 2. 25GE SFP28
1822     - None
1823 3. 40GE QSFP+
1824     - None
1825 4. 100GE
1826     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1827 ```
1828
1829 Standalone cables:
1830
1831 ```
1832 1. 10GE
1833     - None
1834 2. 25GE
1835     - None
1836 3. 40GE QSFP+
1837     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1838 4. 100GE
1839     - None
1840 ```
1841
1842 ### Other Parts