Infra: Ansible Nomad II
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30       1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0
74  3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0
75  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0
76  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
77  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
78  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
79  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0
80  9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
84 13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
85 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0
86                                  Totals: 22   35   18   12   19    1    2    3    1    2    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
137
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
144
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
148
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
150
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 3-Node-MACCHIATObin Arm Marvell
157
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163 ### 3-Node-Rangeley Atom Testbeds
164
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ## Server Management
171
172 ### Requirements
173
174 For management purposes, each server must have following two ports
175 connected to the management network:
176
177 ```
178 - 1GE IPMI port
179   - IPMI - Intelligent Platform Management Interface.
180   - Required for access to embedded server management with WebUI, CLI,
181     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183   - hostOS management port for general system management.
184 ```
185
186 ### Addressing
187
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
190
191 ```
192 1. LOM (IPMI) VLAN:
193     - Subnet: 10.30.50.0/24
194     - Gateway: 10.30.50.1
195     - Broadcast: 10.30.50.255
196     - DNS1: 199.204.44.24
197     - DNS2: 199.204.47.54
198 2. Management Vlan:
199     - Subnet: 10.30.51.0/24
200     - Gateway: 10.30.51.1
201     - Broadcast: 10.30.51.255
202     - DNS1: 199.204.44.24
203     - DNS2: 199.204.47.54
204 ```
205
206 To access these hosts, VPN connection is required.
207
208 ### LOM (IPMI) VLAN IP Addresses
209
210 Name         | Comment
211 ------------ | -------
212 10.30.50.0   | network
213 10.30.51.1   | Router
214 10.30.50.2   | LF Reserved
215 10.30.50.3   | LF Reserved
216 10.30.50.4   | LF Reserved
217 10.30.50.5   | LF Reserved
218 10.30.50.6   | LF Reserved
219 10.30.50.7   | LF Reserved
220 10.30.50.8   | LF Reserved
221 10.30.50.9   | LF Reserved
222 10.30.50.10  | LF Reserved
223 10.30.50.11  | LF Reserved
224 10.30.50.12  | LF Reserved
225 10.30.50.13  | LF Reserved
226 10.30.50.14  | LF Reserved
227 10.30.50.15  | LF Reserved
228 10.30.50.16  | t1-tg1
229 10.30.50.17  | t1-sut1
230 10.30.50.18  | t1-sut2
231 10.30.50.20  | t2-tg1
232 10.30.50.21  | t2-sut1
233 10.30.50.22  | t2-sut2
234 10.30.50.24  | t3-tg1
235 10.30.50.25  | t3-sut1
236 10.30.50.26  | t3-sut-2
237 10.30.50.28  | s41-nomad
238 10.30.50.29  | s39-nomad
239 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30  | s40-nomad
241 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.36  | s17-t33-sut1
244 10.30.50.37  | s18-t33-sut2
245 10.30.50.41  | s3-t21-sut1
246 10.30.50.42  | s4-t21-tg1
247 10.30.50.43  | s11-t31-sut1
248 10.30.50.44  | s12-t31-sut2
249 10.30.50.45  | s13-t31-tg1
250 10.30.50.46  | s19-t33t34-tg1
251 10.30.50.47  | s1-t11-sut1
252 10.30.50.48  | s2-t12-sut1
253 10.30.50.49  | s5-t22-sut1
254 10.30.50.50  | s6-t22-tg1
255 10.30.50.51  | s7-t23-sut1
256 10.30.50.52  | s8-t23-tg1
257 10.30.50.53  | s9-t24-sut1
258 10.30.50.54  | s10-t24-tg1
259 10.30.50.55  | s14-t32-sut1
260 10.30.50.56  | s15-t32-sut2
261 10.30.50.57  | s16-t32-tg1
262 10.30.50.58  | s25-t25-sut1
263 10.30.50.59  | s26-t25-tg1
264 10.30.50.69  | s27-t13-sut
265 10.30.50.255 | Broadcast
266 n/a          | s20-t34-sut1
267 n/a          | s21-t34-sut2
268 10.30.55.0   | network
269 10.30.55.1   | Router
270 10.30.55.10  | s28-t26t35-tg1
271 10.30.55.11  | s29-t26-sut1
272 10.30.55.12  | s30-t35-sut1
273 10.30.55.13  | s31-t35-sut2
274 10.30.55.14  | server-type-c4-1
275 10.30.55.15  | server-type-c4-2
276 10.30.55.17  | s32-t14-sut1
277 10.30.55.18  | s33-t27-sut1
278 10.30.55.19  | s34-t27-tg1
279 10.30.55.20  | s35-t28-sut1
280 10.30.55.21  | s36-t28-tg1
281 10.30.55.22  | s37-t29-sut1
282 10.30.55.23  | s38-t29-tg1
283 10.30.55.255 | Broadcast
284
285 ### Management VLAN IP Addresses
286
287 Name                      | Comment
288 ------------------------- | -------
289 10.30.51.0                | network
290 10.30.51.1                | Router
291 10.30.51.2                | LF Reserved
292 10.30.51.3                | LF Reserved
293 10.30.51.4                | LF Reserved
294 10.30.51.5                | LF Reserved
295 10.30.51.6                | LF Reserved
296 10.30.51.7                | LF Reserved
297 10.30.51.8                | LF Reserved
298 10.30.51.9                | s22-t35-sut1 (netgate-1)
299 10.30.51.10               | s23-t35-sut2 (netgate-2)
300 10.30.51.11               | s24-t35-sut3 (netgate-3)
301 10.30.51.12               | softiron-1
302 10.30.51.13               | nomad1arm
303 10.30.51.14               | nomad2arm
304 10.30.51.15               | LF Reserved
305 10.30.51.16               | t1-tg1
306 10.30.51.17               | t1-sut1
307 10.30.51.18               | t1-sut2
308 10.30.51.20               | t2-tg1
309 10.30.51.21               | t2-sut1
310 10.30.51.22               | t2-sut2
311 10.30.51.24               | t3-tg1
312 10.30.51.25               | t3-sut1
313 10.30.51.26               | t3-sut-2
314 10.30.51.28               | s41-nomad
315 10.30.51.29               | s39-nomad
316 10.30.51.30               | s40-nomad
317 10.30.51.32               | nomad1
318 10.30.51.33               | nomad2
319 10.30.51.36               | s17-t33-sut1
320 10.30.51.37               | s18-t33-sut2
321 10.30.51.41               | s20-t34-sut1
322 10.30.51.42               | s21-t34-sut2
323 10.30.51.44               | s3-t21-sut1
324 10.30.51.45               | s4-t21-tg1
325 10.30.51.46               | s11-t31-sut1
326 10.30.51.47               | s12-t31-sut2
327 10.30.51.48               | s13-t31-tg1
328 10.30.51.49               | s19-t33t34-tg1
329 10.30.51.50               | s1-t11-sut1
330 10.30.51.51               | s2-t12-sut1
331 10.30.51.52               | s5-t22-sut1
332 10.30.51.53               | s6-t22-tg1
333 10.30.51.54               | s7-t23-sut1
334 10.30.51.55               | s8-t23-tg1
335 10.30.51.56               | s9-t24-sut1
336 10.30.51.57               | s10-t24-tg1
337 10.30.51.58               | s14-t32-sut1
338 10.30.51.59               | s15-t32-sut2
339 10.30.51.60               | s16-t32-tg1
340 10.30.51.61               | s25-t25-sut1
341 10.30.51.62               | s26-t25-tg1
342 10.30.51.69               | s27-t13-sut1
343 10.30.51.70-10.30.51.105  | FREE
344 10.30.51.106-10.30.51.180 | FREE
345 10.30.51.181-10.30.51.254 | FREE
346 10.30.51.255              | Broadcast
347 10.32.8.0                | network
348 10.32.8.1                | Router
349 10.32.8.10                | s28-t26t35-tg1
350 10.32.8.11                | s29-t26-sut1
351 10.32.8.12                | s30-t35-sut1
352 10.32.8.13                | s31-t35-sut2
353 10.32.8.14                | server-type-c4-1
354 10.32.8.15                | server-type-c4-2
355 10.32.8.17                | s32-t14-sut1
356 10.32.8.18                | s33-t27-sut1
357 10.32.8.19                | s34-t27-tg1
358 10.32.8.20                | s35-t28-sut1
359 10.32.8.21                | s36-t28-tg1
360 10.32.8.22                | s37-t29-sut1
361 10.32.8.23                | s38-t29-tg1
362 10.32.8.255              | Broadcast
363
364 ## Server Specifications
365
366 ### Server Types
367
368 FD.io CSIT lab contains following server types:
369 ```
370 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
371     - Quantity: 6 servers.
372     - Physical connectivity:
373         - CIMC and host management ports.
374         - NIC ports connected in 3-node topologies.
375     - Main HW configuration:
376         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
377         - Processors: 2* E5-2699v3 2.3 GHz.
378         - RAM Memory: 16* 32GB DDR4-2133MHz.
379         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
380     - NICs configuration:
381         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
382             - PCIe Slot1: Cisco VIC 1385 2p40GE.
383             - PCIe Slot2: Intel NIC x520 2p10GE.
384             - PCIe Slot3: empty.
385         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
386             - PCIe Slot4: Intel NIC xl710 2p40GE.
387             - PCIe Slot5: Intel NIC x710 2p10GE.
388             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
389         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
390 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
391     - Quantity: 3 servers.
392     - Physical connectivity:
393         - CIMC and host management ports.
394         - NIC ports connected in 3-node topologies.
395     - Main HW configuration:
396         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
397         - Processors: 2* E5-2699v3 2.3 GHz.
398         - RAM Memory: 16* 32GB DDR4-2133MHz.
399         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
400     - NICs configuration:
401         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
402             - PCIe Slot1: Intel NIC xl710 2p40GE.
403             - PCIe Slot2: Intel NIC x710 2p10GE.
404             - PCIe Slot3: Intel NIC x710 2p10GE.
405         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
406             - PCIe Slot4: Intel NIC xl710 2p40GE.
407             - PCIe Slot5: Intel NIC x710 2p10GE.
408             - PCIe Slot6: Intel NIC x710 2p10GE.
409         - MLOM slot: empty.
410 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
411     - Quantity: 3 servers.
412     - Physical connectivity:
413         - CIMC and host management ports.
414         - no NIC ports, standalone setup.
415     - Main HW configuration:
416         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
417         - Processors: 2* E5-2699v3 2.3 GHz.
418         - RAM Memory: 16* 32GB DDR4-2133MHz.
419         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
420     - NICs configuration:
421         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
422             - no cards.
423         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
424             - no cards.
425         - MLOM slot: empty.
426 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
427     - Quantity: ---
428     - Physical connectivity:
429         - IPMI and host management ports.
430         - NIC ports connected into 2-node and 3-node topologies.
431     - Main HW configuration:
432         - Chassis: SuperMicro SYS-7049GP-TRT.
433         - Motherboard: SuperMicro X11DPG-QT.
434         - Processors: 2* Intel Platinum 8180 2.5 GHz.
435         - RAM Memory: 16* 16GB DDR4-2666MHz.
436         - Disks: 2* 1.6TB 6G SATA SSD.
437     - NICs configuration:
438         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
439             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
440             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
441             - PCIe Slot9 5e:00.xx: empty.
442         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
443             - PCIe Slot6 86:00.xx: empty.
444             - PCIe Slot8 af:00.xx: empty.
445             - PCIe Slot10 d8:00.xx: empty.
446 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
447     - Quantity: ---
448     - Physical connectivity:
449         - IPMI and host management ports.
450         - NIC ports connected into 2-node and 3-node topologies.
451     - Main HW configuration:
452         - Chassis: SuperMicro SYS-7049GP-TRT.
453         - Motherboard: SuperMicro X11DPG-QT.
454         - Processors: 2* Intel Platinum 8180 2.5 GHz.
455         - RAM Memory: 16* 16GB DDR4-2666MHz.
456         - Disks: 2* 1.6TB 6G SATA SSD.
457     - NICs configuration:
458         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
459             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
460             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
461             - PCIe Slot9 5e:00.xx: empty.
462         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
463             - PCIe Slot6 86:00.xx: empty.
464             - PCIe Slot8 af:00.xx: empty.
465             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
466 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
467     - Quantity: 2
468     - Physical connectivity:
469         - IPMI(?) and host management ports.
470         - NIC ports connected into 3-node topology.
471     - Main HW configuration:
472         - Chassis: Huawei TaiShan 2280.
473         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
474         - RAM Memory: 8* 16GB DDR4-2400MT/s
475         - Disks: 1* 4TB SATA HDD
476     - NICs configuration:
477         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
478         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
479 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
480     - Quantity: 3
481     - Physical connectivity:
482         - Host management ports.
483         - NIC ports connected into 2-node and 3-node topologies.
484     - Main HW configuration:
485         - Chassis: MACCHIATObin.
486         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
487         - RAM Memory: 1* 16GB DDR4
488         - Disks: 1* 128GB(?) SATA SDD
489     - NICs configuration:
490         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
491 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
492     - Quantity: TBD based on testbed allocation.
493     - Physical connectivity:
494         - Management: serial Port (usb) for console
495         - NIC ports connected into 2-node.
496     - Main HW configuration:
497         - Chassis: Netgate XG-2758-1u
498         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
499         - RAM Memory: 16GB ECC
500         - Disks: 150 GB
501     - NICs configuration:
502         - 2x 10Gb Intel 82599ES
503         - 4x 1GB Intel I354
504 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
505     - Quantity: 2.
506     - Physical connectivity:
507         - IPMI and host management ports.
508         - NIC ports connected into 2-node and 3-node topologies.
509     - Main HW configuration:
510         - Chassis: SuperMicro SYS-7049GP-TRT.
511         - Motherboard: SuperMicro X11DPG-QT.
512         - Processors: 2* Intel Platinum 8180 2.5 GHz.
513         - RAM Memory: 16* 16GB DDR4-2666MHz.
514         - Disks: 2* 1.6TB 6G SATA SSD.
515     - NICs configuration:
516         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
517             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
518             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
519             - PCIe Slot9 5e:00.xx: empty.
520         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
521             - PCIe Slot6 86:00.xx: empty.
522             - PCIe Slot8 af:00.xx: empty.
523             - PCIe Slot10 d8:00.xx: empty.
524 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
525     - Quantity: 1.
526     - Physical connectivity:
527         - Host management interface: 10/100/1000-BaseT.
528         - 8-port 10GE SFP+ integrated NIC.
529     - Main HW configuration:
530         - Chassis: PS10GE4NG.
531         - Motherboard: SuperMicro X11DPG-QT.
532         - Processors: Quad-Core, Intel Processor.
533         - HW accelerators: FPGA offload.
534         - RAM Memory: 64GB.
535         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
536         - Physical Interfaces: 4 * 10GE SFP+.
537         - Operating System: Native IxOS.
538     - Interface configuration:
539         - Port-1: 10GE SFP+.
540         - Port-2: 10GE SFP+.
541         - Port-3: 10GE SFP+.
542         - Port-4: 10GE SFP+.
543 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
544     - Quantity: 1.
545     - Physical connectivity:
546         - IPMI and host management ports.
547         - NIC ports.
548     - Main HW configuration:
549         - Chassis: SuperMicro SYS-7049GP-TRT.
550         - Motherboard: SuperMicro X11DPG-QT.
551         - Processors: 2* Intel Platinum 8180 2.5 GHz.
552         - RAM Memory: 16* 16GB DDR4-2666MHz.
553         - Disks: 2* 1.6TB 6G SATA SSD.
554     - NICs configuration:
555         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
556             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
557             - PCIe Slot4 3b:00.xx: empty.
558             - PCIe Slot9 5e:00.xx: empty.
559         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
560             - PCIe Slot6 86:00.xx: empty.
561             - PCIe Slot8 af:00.xx: empty.
562             - PCIe Slot10 d8:00.xx: empty.
563 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
564     - Quantity: 1
565     - Physical connectivity:
566         - IPMI and host management ports.
567         - NIC ports connected into 1-node topologies.
568     - Main HW configuration:
569         - Chassis: Gigabyte R181-T90 1U
570         - Motheboard: MT91-FS1
571         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
572         - RAM Memory: 4* 32GB RDIMM
573         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
574     - NICs configuration:
575         - Numa0:
576             - PCIe Slot1 05:00.xx: XL710-QDA2.
577             - PCIe Slot3 08:00.xx: XL710-QDA2.
578         - Numa1:
579             - PCIe Slot6 85:00.xx: XL710-QDA2.
580 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
581     - Quantity: 4
582     - Physical connectivity:
583         - IPMI and host management ports.
584         - NIC ports.
585     - Main HW configuration:
586         - Chassis: SuperMicro SYS-E300-9A
587         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
588         - RAM Memory: 32GB ECC
589         - Disks: 480 GB
590     - NICs configuration:
591         - 2x 10Gb Intel x553 fiber ports
592         - 2x 10Gb Intel x553 copper ports
593         - 4x 1GB Intel I350 ports
594
595 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
596     - Quantity: 1.
597     - Physical connectivity:
598         - IPMI and host management ports.
599         - NIC ports connected into 1-node testbed topologies.
600     - Main HW configuration:
601         - Chassis: SuperMicro SYS-7049GP-TRT.
602         - Motherboard: SuperMicro X11DPG-QT.
603         - Processors: 2* Intel Platinum 8280 2.7 GHz.
604         - RAM Memory: 12* 16GB DDR4-2933.
605         - Disks: 2* 1.92TB SATA SSD.
606     - NICs configuration:
607         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
608             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
609             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
610             - PCIe Slot9 5e:00.xx: empty.
611         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
612             - PCIe Slot6 86:00.xx: empty.
613             - PCIe Slot8 af:00.xx: empty.
614             - PCIe Slot10 d8:00.xx: empty.
615
616 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
617     - Quantity: 3
618     - Physical connectivity:
619         - IPMI and host management ports.
620         - NIC ports connected into 2-node testbed topologies.
621     - Main HW configuration:
622         - Chassis: SuperMicro SYS-7049GP-TRT.
623         - Motherboard: SuperMicro X11DPG-QT.
624         - Processors: 2* Intel Gold 6252N 2.3 GHz.
625         - RAM Memory: 12* 16GB DDR4-2933.
626         - Disks: 2* 1.92TB SATA SSD.
627     - NICs configuration:
628         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
629             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
630             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
631             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
632               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
633         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
634             - PCIe Slot6 86:00.xx: empty.
635             - PCIe Slot8 af:00.xx: empty.
636             - PCIe Slot10 d8:00.xx: empty.
637 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
638     - Quantity: 3.
639     - Physical connectivity:
640         - IPMI and host management ports.
641         - NIC ports connected into 2-node testbed topologies.
642     - Main HW configuration:
643         - Chassis: SuperMicro SYS-7049GP-TRT.
644         - Motherboard: SuperMicro X11DPG-QT.
645         - Processors: 2* Intel Platinum 8280 2.7 GHz.
646         - RAM Memory: 12* 16GB DDR4-2933.
647         - Disks: 2* 1.92TB SATA SSD.
648     - NICs configuration:
649         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
650             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
651             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
652             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
653               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
654         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
655             - PCIe Slot6 86:00.xx: empty.
656             - PCIe Slot8 af:00.xx: empty.
657             - PCIe Slot10 d8:00.xx: empty.
658
659 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
660     - Quantity: 3.
661     - Physical connectivity:
662         - CIMC and host management ports.
663         - no NIC ports, standalone setup.
664     - Main HW configuration:
665         - Chassis: SuperMicro 1029P-WTRT.
666         - Motherboard: SuperMicro X11DDW-NT.
667         - Processors: 2* Intel Platinum 8280 2.7 GHz.
668         - RAM Memory: 12* 16GB DDR4-2933.
669         - Disks: 4* 1.92TB SATA SSD.
670     - NICs configuration:
671         - Numa0:
672             - no cards.
673         - Numa1:
674             - no cards.
675 ```
676
677 ### Naming Convention
678
679 Following naming convention is used within this page to specify physical
680 connectivity and wiring across defined CSIT testbeds:
681
682 ```
683 - testbedname: testbedN.
684 - hostname:
685     - traffic-generator: tN-tgW.
686     - system-under-testX: tN-sutX.
687 - portnames:
688     - tN-tgW-cY/pZ.
689     - tN-sutX-cY/pZ.
690 - where:
691     - N - testbed number.
692     - tgW - server acts as traffic-generator with W index.
693     - sutX - server acts as system-under-test with X index.
694     - Y - PCIe slot number denoting a NIC card number within the host.
695     - Z - port number on the NIC card.
696 ```
697
698 ## Testbeds Configuration
699
700 ### Per Testbed Server Allocation and Naming
701
702 #### 1-Node-Skylake Servers (1n-skx) PROD
703
704 ```
705 - SUT [Server-Type-B6]:
706     - testbedname: testbed11.
707     - hostname: s1-t11-sut1.
708     - IPMI IP: 10.30.50.47
709     - Host IP: 10.30.51.50
710     - portnames:
711         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
712         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
713         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
714         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
715         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
716         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
717         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
718         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
719 - SUT [Server-Type-B6]:
720     - testbedname: testbed12.
721     - hostname: s2-t12-sut1.
722     - IPMI IP: 10.30.50.48
723     - Host IP: 10.30.51.51
724     - portnames:
725         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
726         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
727         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
728         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
729         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
730         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
731         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
732         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
733 ```
734
735 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
736
737 ```
738 - SUT [Server-Type-B9]:
739     - testbedname: testbed13.
740     - hostname: s27-t13-sut1.
741     - IPMI IP: 10.30.50.69
742     - Host IP: 10.30.51.69
743     - portnames:
744         - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
745         - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
746         - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
747         - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
748         - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
749         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
750 ```
751
752 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
753
754 ```
755 - SUT [Server-Type-C1]:
756     - testbedname: testbed11.
757     - hostname: s32-t14-sut1.
758     - IPMI IP: 10.30.55.17
759     - Host IP: 10.32.8.17
760     - portnames:
761         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
762         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
763         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
764         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
765         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
766         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
767         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
768         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
769 ```
770
771 #### 2-Node-Skylake Servers (2n-skx) PROD
772
773 ```
774 - SUT [Server-Type-B1]:
775     - testbedname: testbed21.
776     - hostname: s3-t21-sut1.
777     - IPMI IP: 10.30.50.41
778     - Host IP: 10.30.51.44
779     - portnames:
780         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
781         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
782         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
783         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
784         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
785         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
786 - TG [Server-Type-B2]:
787     - testbedname: testbed21.
788     - hostname: s4-t21-tg1.
789     - IPMI IP: 10.30.50.42
790     - Host IP: 10.30.51.45
791     - portnames:
792         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
793         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
794         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
795         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
796         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
797         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
798 - SUT [Server-Type-B1]:
799     - testbedname: testbed22.
800     - hostname: s5-t22-sut1.
801     - IPMI IP: 10.30.50.49
802     - Host IP: 10.30.51.52
803     - portnames:
804         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
805         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
806         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
807         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
808         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
809         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
810 - TG [Server-Type-B2]:
811     - testbedname: testbed22.
812     - hostname: s6-t22-tg1.
813     - IPMI IP: 10.30.50.50
814     - Host IP: 10.30.51.53
815     - portnames:
816         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
817         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
818         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
819         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
820         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
821         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
822 - SUT [Server-Type-B1]:
823     - testbedname: testbed23.
824     - hostname: s7-t23-sut1.
825     - IPMI IP: 10.30.50.51
826     - Host IP: 10.30.51.54
827     - portnames:
828         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
829         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
830         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
831         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
832         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
833         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
834 - TG [Server-Type-B2]:
835     - testbedname: testbed23.
836     - hostname: s8-t23-tg1.
837     - IPMI IP: 10.30.50.52
838     - Host IP: 10.30.51.55
839     - portnames:
840         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
841         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
842         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
843         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
844         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
845         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
846 - SUT [Server-Type-B1]:
847     - testbedname: testbed24.
848     - hostname: s9-t24-sut1.
849     - IPMI IP: 10.30.50.53
850     - Host IP: 10.30.51.56
851     - portnames:
852         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
853         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
854         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
855         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
856         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
857         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
858 - TG [Server-Type-B2]:
859     - testbedname: testbed24.
860     - hostname: s10-t24-tg1.
861     - IPMI IP: 10.30.50.54
862     - Host IP: 10.30.51.57
863     - portnames:
864         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
865         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
866         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
867         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
868         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
869         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
870 ```
871
872 #### 2-Node-Denverton Servers (2n-dnv) WIP
873
874 Note: ServerB28 (TG) is shared between testbed26 & testbed35
875
876 ```
877 - TG [Server-Type-B2]:
878     - testbednames: testbed26 and testbed35.
879     - hostname: s28-t26t35-tg1.
880     - IPMI IP: 10.30.55.10
881     - Host IP: 10.32.8.10
882     - portnames:
883         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
884         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
885         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
886         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
887         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
888         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
889         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
890         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
891         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
892         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
893         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
894         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
895 - SUT [Server-Type-B10]:
896     - testbednames: testbed26.
897     - hostname: s29-t26-sut1.
898     - IPMI IP: 10.30.55.11
899     - Host IP: 10.32.8.11
900     - portnames:
901         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
902         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
903         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
904         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
905 ```
906
907 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
908
909 ```
910 - SUT [Server-Type-B8]:
911     - testbedname: testbed25.
912     - hostname: s25-t25-sut1.
913     - IPMI IP: 10.30.50.58
914     - Host IP: 10.30.51.61
915     - portnames:
916         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
917         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
918         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
919         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
920 - TG [Server-Type-B7]:
921     - testbedname: testbed25.
922     - hostname: s26-t25-tg1.
923     - IPMI IP: 10.30.50.59
924     - Host IP: 10.30.51.62
925     - portnames:
926         - s26-t25-tg1-p1 - 10GE-port1.
927         - s26-t25-tg1-p2 - 10GE-port2.
928         - s26-t25-tg1-p3 - 10GE-port3.
929         - s26-t25-tg1-p4 - 10GE-port4.
930 ```
931
932 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
933
934 ```
935 - SUT [Server-Type-C2]:
936     - testbedname: testbed27.
937     - hostname: s33-t27-sut1.
938     - IPMI IP: 10.30.55.18
939     - Host IP: 10.32.8.18
940     - portnames:
941         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
942         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
943         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
944         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
945         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
946         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
947         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
948         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
949 - TG [Server-Type-C3]:
950     - testbedname: testbed27.
951     - hostname: s34-t27-tg1.
952     - IPMI IP: 10.30.55.19
953     - Host IP: 10.32.8.19
954     - portnames:
955         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
956         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
957         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
958         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
959         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
960         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
961         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
962         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
963 - SUT [Server-Type-C2]:
964     - testbedname: testbed28.
965     - hostname: s35-t28-sut1.
966     - IPMI IP: 10.30.55.20
967     - Host IP: 10.32.8.20
968     - portnames:
969         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
970         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
971         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
972         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
973         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
974         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
975         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
976         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
977 - TG [Server-Type-C3]:
978     - testbedname: testbed28.
979     - hostname: s36-t28-tg1.
980     - IPMI IP: 10.30.55.21
981     - Host IP: 10.32.8.21
982     - portnames:
983         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
984         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
985         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
986         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
987         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
988         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
989         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
990         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
991 - SUT [Server-Type-C2]:
992     - testbedname: testbed29.
993     - hostname: s37-t29-sut1.
994     - IPMI IP: 10.30.55.22
995     - Host IP: 10.32.8.22
996     - portnames:
997         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
998         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
999         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1000         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1001         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1002         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1003         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1004         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1005 - TG [Server-Type-C3]:
1006     - testbedname: testbed29.
1007     - hostname: s38-t29-tg1.
1008     - IPMI IP: 10.30.55.23
1009     - Host IP: 10.32.8.23
1010     - portnames:
1011         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1012         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1013         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1014         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1015         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1016         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1017         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1018         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1019 ```
1020
1021 #### 3-Node-Haswell Servers (3n-hsw) PROD
1022
1023 ```
1024  1. SUT [Server-Type-A1]:
1025     - testbedname: testbed1.
1026     - hostname: t1-sut1.
1027     - CIMC IP: 10.30.50.17
1028     - Host IP: 10.30.51.17
1029     - portnames:
1030         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1031         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1032         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1033         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1034         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1035         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1036         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1037         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1038         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1039         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1040  2. SUT [Server-Type-A1]:
1041     - testbedname: testbed1.
1042     - hostname: t1-sut2.
1043     - CIMC IP: 10.30.50.18
1044     - Host IP: 10.30.51.18
1045     - portnames:
1046         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1047         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1048         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1049         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1050         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1051         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1052         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1053         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1054         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1055         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1056  3. TG [Server-Type-A2]:
1057     - testbedname: testbed1.
1058     - hostname: t1-tg1.
1059     - CIMC IP: 10.30.50.16
1060     - Host IP: 10.30.51.16
1061     - portnames:
1062         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1063         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1064         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1065         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1066         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1067         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1068         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1069         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1070         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1071         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1072         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1073         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1074  4. SUT [Server-Type-A1]:
1075     - testbedname: testbed2.
1076     - hostname: t2-sut1.
1077     - CIMC IP: 10.30.50.21
1078     - Host IP: 10.30.51.21
1079     - portnames:
1080         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1081         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1082         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1083         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1084         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1085         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1086         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1087         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1088         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1089         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1090  5. SUT [Server-Type-A1]:
1091     - testbedname: testbed2.
1092     - hostname: t2-sut2.
1093     - CIMC IP: 10.30.50.22
1094     - Host IP: 10.30.51.22
1095     - portnames:
1096         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1097         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1098         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1099         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1100         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1101         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1102         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1103         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1104         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1105         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1106  6. TG [Server-Type-A2]:
1107     - testbedname: testbed2.
1108     - hostname: t2-tg1.
1109     - CIMC IP: 10.30.50.20
1110     - Host IP: 10.30.51.20
1111     - portnames:
1112         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1113         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1114         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1115         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1116         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1117         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1118         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1119         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1120         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1121         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1122         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1123         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1124  7. SUT [Server-Type-A1]:
1125     - testbedname: testbed3.
1126     - hostname: t3-sut1.
1127     - CIMC IP: 10.30.50.25
1128     - Host IP: 10.30.51.25
1129     - portnames:
1130         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1131         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1132         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1133         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1134         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1135         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1136         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1137         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1138         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1139         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1140  8. SUT [Server-Type-A1]:
1141     - testbedname: testbed3.
1142     - hostname: t3-sut2.
1143     - CIMC IP: 10.30.50.26
1144     - Host IP: 10.30.51.26
1145     - portnames:
1146         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1147         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1148         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1149         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1150         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1151         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1152         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1153         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1154         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1155         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1156  9. TG [Server-Type-A2]:
1157     - testbedname: testbed3.
1158     - hostname: t3-tg1.
1159     - CIMC IP: 10.30.50.24
1160     - Host IP: 10.30.51.24
1161     - portnames:
1162         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1163         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1164         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1165         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1166         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1167         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1168         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1169         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1170         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1171         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1172         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1173         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1174 ```
1175
1176 #### 3-Node-Skylake Servers (3n-skx) PROD
1177
1178 ```
1179 - ServerB11 [Server-Type-B1]:
1180     - testbedname: testbed31.
1181     - hostname: s11-t31-sut1.
1182     - IPMI IP: 10.30.50.43
1183     - Host IP: 10.30.51.46
1184     - portnames:
1185         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1186         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1187         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1188         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1189         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1190         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1191         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1192         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1193 - ServerB12 [Server-Type-B1]:
1194     - testbedname: testbed31.
1195     - hostname: s12-t31-sut2.
1196     - IPMI IP: 10.30.50.44
1197     - Host IP: 10.30.51.47
1198     - portnames:
1199         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1200         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1201         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1202         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1203         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1204         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1205         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1206         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1207 - ServerB13 [Server-Type-B2]:
1208     - testbedname: testbed31.
1209     - hostname: s13-t31-tg1.
1210     - IPMI IP: 10.30.50.45
1211     - Host IP: 10.30.51.48
1212     - portnames:
1213         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1214         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1215         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1216         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1217         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1220         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1221 - ServerB14 [Server-Type-B1]:
1222     - testbedname: testbed32.
1223     - hostname: s14-t32-sut1.
1224     - IPMI IP: 10.30.50.55
1225     - Host IP: 10.30.51.58
1226     - portnames:
1227         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1228         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1229         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1230         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1231         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1232         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1233         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1234         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1235 - ServerB15 [Server-Type-B1]:
1236     - testbedname: testbed32.
1237     - hostname: s15-t32-sut2.
1238     - IPMI IP: 10.30.50.56
1239     - Host IP: 10.30.51.59
1240     - portnames:
1241         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1242         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1243         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1244         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1245         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1246         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1247         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1248         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1249 - ServerB16 [Server-Type-B2]:
1250     - testbedname: testbed32.
1251     - hostname: s16-t32-tg1.
1252     - IPMI IP: 10.30.50.57
1253     - Host IP: 10.30.51.60
1254     - portnames:
1255         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1256         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1257         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1258         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1259         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1260         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1261         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1262         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1263 ```
1264
1265 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1266
1267 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1268
1269 ```
1270 - ServerB22 [Server-Type-B5]:
1271     - testbedname: testbed35.
1272     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1273     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1274     - Host IP: 10.30.51.9
1275     - portnames:
1276         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1277         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1278     - 1GB ports (tbd)
1279 - ServerB23 [Server-Type-B5]:
1280     - testbedname: testbed35.
1281     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1282     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1283     - Host IP: 10.30.51.10
1284     - portnames:
1285         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1286         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1287     - 1GB ports (tbd)
1288 - ServerB24 [Server-Type-B5]:
1289     - testbedname: testbed35.
1290     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1291     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1292     - Host IP: 10.30.51.11
1293     - portnames:
1294         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1295         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1296     - 1GB ports (tbd)
1297 ```
1298
1299 #### 3-Node-Taishan Servers (3n-tsh) WIP
1300
1301 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1302
1303 ```
1304 - ServerB17 [Server-Type-B3]:
1305     - testbedname: testbed33.
1306     - hostname: s17-t33-sut1.
1307     - IPMI IP: 10.30.50.36
1308     - Host IP: 10.30.51.36
1309     - portnames:
1310         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1311         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1312         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1313         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1314 - ServerB18 [Server-Type-B3]:
1315     - testbedname: testbed33.
1316     - hostname: s18-t33-sut2.
1317     - IPMI IP: 10.30.50.37
1318     - Host IP: 10.30.51.37
1319     - portnames:
1320         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1321         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1322         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1323         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1324 - ServerB19 [Server-Type-B2]:
1325     - testbednames: testbed33 and testbed34.
1326     - hostname: s19-t33t34-tg1.
1327     - IPMI IP: 10.30.50.46
1328     - Host IP: 10.30.51.49
1329     - portnames:
1330         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1331         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1332         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1333         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1334         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1335         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1336         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1337         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1338         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1339         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1340 - ServerB20 [Server-Type-B4]:
1341     - testbedname: testbed34.
1342     - hostname: s20-t34-sut1.
1343     - IPMI IP: N/A
1344     - Host IP: 10.30.51.41
1345     - portnames:
1346         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1347         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1348 - ServerB21 [Server-Type-B4]:
1349     - testbedname: testbed34.
1350     - hostname: s21-t34-sut2.
1351     - IPMI IP: N/A
1352     - Host IP: 10.30.51.42
1353     - portnames:
1354         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1355         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1356 ```
1357
1358 #### 3-Node-Denverton Servers (3n-dnv) WIP
1359
1360 ```
1361 - ServerB30 [Server-Type-B10]:
1362     - testbednames: testbed35.
1363     - hostname: s30-t35-sut1.
1364     - IPMI IP: 10.30.55.12
1365     - Host IP: 10.32.8.12
1366     - portnames:
1367         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1368         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1369         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1370         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1371 - ServerB31 [Server-Type-B10]:
1372     - testbednames: testbed35.
1373     - hostname: s31-t35-sut2.
1374     - IPMI IP: 10.30.55.13
1375     - Host IP: 10.32.8.13
1376     - portnames:
1377         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1378         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1379         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1380         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1381 ```
1382
1383 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1384
1385 ```
1386 To be completed.
1387 ```
1388
1389 ### Per Testbed Wiring
1390
1391 #### 1-Node-Skylake Wiring (1n-skx) PROD
1392
1393 ```
1394 - testbed11:
1395     - ring1 10GE-ports x710-4p10GE:
1396         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1397     - ring2 10GE-ports x710-4p10GE:
1398         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1399     - ring3 10GE-ports x710-4p10GE:
1400         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1401     - ring4 10GE-ports x710-4p10GE:
1402         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1403 - testbed12:
1404     - ring1 10GE-ports x710-4p10GE:
1405         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1406     - ring2 10GE-ports x710-4p10GE:
1407         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1408     - ring3 10GE-ports x710-4p10GE:
1409         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1410     - ring4 10GE-ports x710-4p10GE:
1411         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1412 ```
1413
1414 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1415
1416 ```
1417 - testbed13:
1418     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1419         - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1420     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1421         - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1422     - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1423         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1424 ```
1425
1426 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1427
1428 ```
1429 - testbed14:
1430     - ring1 10GE-ports x710-4p10GE:
1431         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1432     - ring2 10GE-ports x710-4p10GE:
1433         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1434     - ring3 10GE-ports x710-4p10GE:
1435         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1436     - ring4 10GE-ports x710-4p10GE:
1437         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1438 ```
1439
1440 #### 2-Node-Skylake Wiring (2n-skx) PROD
1441
1442 ```
1443 - testbed21:
1444     - ring1 10GE-ports x710-4p10GE on SUT:
1445         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1446         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1447     - ring2 10GE-ports x710-4p10GE on SUT:
1448         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1449         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1450     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1451         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1452         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1453 - testbed22:
1454     - ring1 10GE-ports x710-4p10GE on SUT:
1455         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1456         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1457     - ring2 10GE-ports x710-4p10GE on SUT:
1458         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1459         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1460     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1461         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1462         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1463 - testbed23:
1464     - ring1 10GE-ports x710-4p10GE on SUT:
1465         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1466         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1467     - ring2 10GE-ports x710-4p10GE on SUT:
1468         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1469         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1470     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1471         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1472         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1473 - testbed24:
1474     - ring1 10GE-ports x710-4p10GE on SUT:
1475         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1476         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1477     - ring2 10GE-ports x710-4p10GE on SUT:
1478         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1479         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1480     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1481         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1482         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1483 ```
1484
1485 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1486
1487 ```
1488 - testbed26:
1489     - ring1 10GE-ports x553 copper port on SUT:
1490         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1491         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1492     - ring2 10GE-ports x553 fiber port on SUT:
1493         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1494         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1495 ```
1496
1497 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1498
1499 ```
1500 - testbed25:
1501     - link1 10GE-port x710-4p10GE on SUT:
1502         - t25-tg1-p1 to t25-sut1-c2/p1.
1503     - link2 10GE-port x710-4p10GE on SUT:
1504         - t25-tg1-p2 to t25-sut1-c2/p2.
1505     - link3 10GE-port x710-4p10GE on SUT:
1506         - t25-tg1-p3 to t25-sut1-c2/p3.
1507     - link4 10GE-port x710-4p10GE on SUT:
1508         - t25-tg1-p4 to t25-sut1-c2/p4.
1509 ```
1510
1511 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1512
1513 ```
1514 - testbed27:
1515     - ring1 10GE-ports x710-4p10GE on SUT:
1516         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1517         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1518     - ring2 10GE-ports x710-4p10GE on SUT:
1519         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1520         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1521     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1522         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1523         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1524     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1525         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1526         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1527 - testbed28:
1528     - ring1 10GE-ports x710-4p10GE on SUT:
1529         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1530         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1531     - ring2 10GE-ports x710-4p10GE on SUT:
1532         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1533         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1534     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1535         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1536         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1537     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1538         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1539         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1540 - testbed29:
1541     - ring1 10GE-ports x710-4p10GE on SUT:
1542         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1543         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1544     - ring2 10GE-ports x710-4p10GE on SUT:
1545         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1546         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1547     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1548         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1549         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1550     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1551         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1552         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1553 ```
1554
1555 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1556
1557 ```
1558  1. testbed1:
1559     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1560         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1561         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1562         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1563     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1564         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1565         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1566         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1567     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1568         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1569         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1570         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1571     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1572         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1573         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1574         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1575     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1576         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1577         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1578         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1579     - TG loopback ports Intel NIC x710 2p10GE
1580         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1581
1582  2. testbed2:
1583     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1584         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1585         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1586         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1587     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1588         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1589         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1590         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1591     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1592         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1593         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1594         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1595     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1596         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1597         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1598         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1599     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1600         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1601         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1602         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1603     - TG loopback ports Intel NIC x710 2p10GE
1604         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1605
1606  3. testbed3:
1607     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1608         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1609         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1610         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1611     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1612         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1613         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1614         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1615     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1616         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1617         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1618         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1619     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1620         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1621         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1622         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1623     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1624         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1625         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1626         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1627     - TG loopback ports Intel NIC x710 2p10GE
1628         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1629 ```
1630
1631 #### 3-Node-Skylake Wiring (3n-skx) PROD
1632
1633 ```
1634 - testbed31:
1635     - ring1 10GE-ports x710-4p10GE on SUTs:
1636         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1637         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1638         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1639     - ring2 10GE-ports x710-4p10GE on SUT:
1640         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1641         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1642         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1643     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1644         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1645         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1646         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1647     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1648         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1649         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1650         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1651     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1652         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1653         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1654 - testbed32:
1655     - ring1 10GE-ports x710-4p10GE on SUTs:
1656         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1657         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1658         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1659     - ring2 10GE-ports x710-4p10GE on SUT:
1660         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1661         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1662         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1663     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1664         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1665         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1666         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1667     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1668         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1669         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1670         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1671     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1672         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1673         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1674 ```
1675
1676 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1677
1678 ```
1679 To be completed.
1680 ```
1681
1682 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1683
1684 ```
1685 - testbed33:
1686     - ring1 10GE-ports x520-2p10GE on SUTs:
1687         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1688         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1689         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1690     - ring2 25GE-ports cx4-2p25GE on SUTs:
1691         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1692         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1693         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1694 ```
1695
1696 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1697
1698 ```
1699 - testbed34:
1700     - ring1 10GE-ports Marvell on SUTs:
1701         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1702         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1703         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1704 ```
1705
1706 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1707
1708 ```
1709 - testbed35:
1710     - ring1 10GE-ports x553 copper port on SUTs:
1711         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1712         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1713         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1714     - ring2 10GE-ports x553 fiber port on SUTs:
1715         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1716         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1717         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1718 ```
1719
1720 ## Inventory
1721
1722 ### Appliances
1723
1724 ```
1725 1. Ixia PerfectStorm One Appliance
1726     - 1 * PS10GE4NG
1727         - Chassis: PS10GE4NG.
1728         - Motherboard: SuperMicro X11DPG-QT.
1729         - Processors: Quad-Core, Intel Processor.
1730         - HW accelerators: FPGA offload.
1731         - RAM Memory: 64GB.
1732         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1733         - Physical Interfaces: 4 * 10GE SFP+.
1734         - Operating System: Native IxOS.
1735 ```
1736
1737 ### Arm Servers
1738
1739 ```
1740 1. Arm Cortex A-72 servers
1741     - 1 * ThunderX2
1742         - Chassis: Marvell ThunderX2
1743         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1744         - RAM Memory: 4* 32GB RDIMM
1745         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1746     - 2 * Huawei TaiShan 2280.
1747         - Chassis: Huawei TaiShan 2280.
1748         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1749         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1750         - Disks: 1* 4TB SATA HDD.
1751     - 3 * MACCHIATObin
1752         - Chassis: MACCHIATObin.
1753         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1754         - RAM Memory: 1* 16GB DDR4.
1755         - Disks: 1* 128GB(?) SATA SDD.
1756 ```
1757
1758 ### Xeon and Atom Servers
1759
1760 ```
1761 1. Intel Xeon servers:
1762     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1763         - Chassis: SuperMicro SYS-7049GP-TRT.
1764         - Motherboard: SuperMicro X11DPG-QT.
1765         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1766         - RAM Memory: 16* 16GB DDR4-2666MHz.
1767         - Disks: 2* 1.6TB 6G SATA SSD.
1768 2. Intel Atom servers with Rangely processors.
1769     - 3 * Netgate XG-2758-1u
1770         - Chassis: Netgate XG-2758-1u
1771         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1772         - RAM Memory: 16GB ECC
1773         - Disks: 150 GB
1774 ```
1775
1776 ### Network Interface Cards
1777
1778 ```
1779 1. 10GE NICs
1780     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1781     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1782     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1783 2. 25GE NICs
1784     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1785 3. 40GE NICs
1786     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1787 4. 100GE NICs
1788     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1789 ```
1790
1791 ### Pluggables and Cables
1792
1793 Pluggables:
1794
1795 ```
1796 1. 10GE SFP+
1797     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1798     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1799 2. 25GE SFP28
1800     - None
1801 3. 40GE QSFP+
1802     - None
1803 4. 100GE
1804     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1805 ```
1806
1807 Standalone cables:
1808
1809 ```
1810 1. 10GE
1811     - None
1812 2. 25GE
1813     - None
1814 3. 40GE QSFP+
1815     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1816 4. 100GE
1817     - None
1818 ```
1819
1820 ### Other Parts
1821
1822 None.